1 PassivHaus/ EnerPHit Introduction Maiia Guermanova behalf of

2 PassivHaus/ EnerPHit What is a PassivHaus/ Passive House? Passivhaus is not a brand name but a building standard that provides a high level of occupant comfort while using very little energy that is truly energy efficient, comfortable, ecological and affordable. They are built with meticulous attention to detail and rigorous design and construction according to principles developed by Passivhaus Institute in Germany and Prof. Dr Wolfgang Feist. Passivhaus can be certified through a quality assurance process. Typical house 100W /m 2 Passivhaus 10W /m 2 A PassivHaus is a building, for which thermal comfort (ISO 7730) can be achieved solely by post-heating or post-cooling of the fresh air mass, which is required to achieve sufficient indoor air quality conditions without the need for additional recirculation of air. Passivhaus Introduction - Page 2

3 PassivHaus/ EnerPHit First Passivhaus Darmstadt-Kranichstein (1991) Passivhaus used energy sources inside the building such as the body heat from the people and solar radiation entering the building. Passivhaus still needs heating but very little. Heating loads occurring in the Passivhaus during the winter is less than 10 W/m². The remaining heating could be easily supplied via the supply air system. images courtesy: PHI Passivhaus Introduction - Page 3

4 PassivHaus/ EnerPHit PassivHaus criteria MHRV 75% efficiency Elec. demand 0.45Wh/m 3 Uw 0.8 W/m 2.K g-value 50% n U 0.15 W/m 2.K Psi-value 0.01W/m.K images courtesy: New Avenue Blog Heating/ cooling demand 25 kwh/m 2.annum Total primary energy demand of 120 kwh/m 2.annum Passivhaus Introduction - Page 4

5 PassivHaus/ EnerPHit EnerPhit criteria (developed in 2011) images courtesy: bere:architects Heating/ cooling demand 25 kwh/m 2.annum Total primary energy demand 120 kwh/m 2 per annum + heat load factor Airtightness n Pa Passivhaus Introduction - Page 5

6 PassivHaus/ EnerPHit Why build Passive? Passivhaus is a fabric-first building standard that can be applied to all building types. Traditional: Lena Gardens PH retrofit, London - CIBSE Building Performance Award 2013 Social housing: Tigh-Na-Cladach (house by the shore), Dunoon - first domestic PH is Scotland 2010 Non-domestic: Mayville Community Centre - first nondomestic PH retrofit 2011 images courtesy: Green Tomato Energy images courtesy: Scottish Passivhaus Centre images courtesy: bere:architects Passivhaus Introduction - Page 6

7 PassivHaus/ EnerPHit Why build Passive? PassivHaus allows for energy savings of up to 90% compared with typical central European buildings and over 75% compared with new dwellings in UK. This offers a great saving on the house owner s energy bills! A typical 3-bed Passivhaus in the UK would have heating bills as low as 100 per year. images courtesy: Green Tomato Energy Passivhaus Introduction - Page 7

8 PassivHaus/ EnerPHit Why build Passive? PassivHaus is built to last. Institutes ensures the quality of construction is achieved whereby the designer has to provide proof there are no cold bridging in the building and the contractor has to monitor and record the progress of the project. Thus avoiding risks of interstitial condensation occurring on cold surfaces in the fabric and vapour diffusion where there are gaps in waterproofing layer. Passivhaus Introduction - Page 8

9 PassivHaus/ EnerPHit Why build Passive? PassivHaus is a fabric first approach. It does not rely on renewable energy sources for energy savings. Heating can be delivered using traditional wet heating system, through the air or any other system. Opt 1: Wet heating system Opt 2: Air heating Opt 3: Solar thermals/ PVs not Opt 4: essential Passivhaus Introduction - Page 9

10 PassivHaus/ EnerPHit Why build Passive? Triple-glazed windows ensure there is no radiation temperature asymmetry, with all surfaces above 17 o C making the building very comfortable to live in. Monitoring data (Temp and Relative Humidity) for Passivhaus Retrofit, Dec 2011 images courtesy: bere:architects Passivhaus Introduction - Page 10

11 PassivHaus/ EnerPHit Why build Passive? The continuously operating comfort ventilation system provides a constant supply of fresh air. The intake filter keeps the home dust free and healthy. Passivhaus Introduction - Page 11

12 PassivHaus/ EnerPHit Why build Passive? PassivHaus performs as designed compared to the majority of buildings that tend to consume considerably more energy than estimated. MEASURED vs PREDICTED heat losses for 16 new dwellings in UK images courtesy: Bell M., Smith M.B., and Palmer J. (2010) Review of the implementation of Part L 2006 Passivhaus Introduction - Page 12

13 PassivHaus/ EnerPHit Why build Passive? Passivhaus Planning Package (PHPP) software is used to accurately estimate the building s energy demand that takes into consideration all thermal elements, cold bridging, shading, MHRV and all electrical appliances. Specific building demands with reference to the treated floor area use: Annual method Treated floor area 74.4 m! Requirements Fulfilled?* Space heating Annual heating demand 22 kwh/(m 2 a) 25 kwh/(m!a) yes Heating load 15 W/m Space cooling Overall specific space cooling demand kwh/(m 2 a) - - Cooling load W/m Frequency of overheating (> 25 C) 0.0 % - - Primary Energy Space heating and cooling, dehumidification, DHW, household electricity. Auxiliary Electricity and 125 kwh/(m 2 a) 129 kwh/(m!a) yes DHW, space heating and auxiliary electricity 94 kwh/(m 2 a) - - Specific primary energy reduction through solar electricity kwh/(m 2 a) - - Airtightness Pressurization test result n /h 1 1/h yes Specific losses, gains, heating demand [kwh/(m! month)] Sum Spec. Gains Solar + Internal Spec. Heating Demand Sum Spec. Losses Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Passivhaus Introduction - Page 13

14 PassivHaus/ EnerPHit Certification process The Passivhaus Institute has developed a series of certification processes to ensure the quality of any official Passivhaus buildings and practitioners: 1. Designers who have the expertise to deliver Passivhaus buildings. 2. Passivhaus building which applies both to the proposed design and the completed building. 3. Components can be recognised by the use of the PassivHaus Institute logo and include windows and ventilation heat recovery systems.

15 Passmore Street EnerPHit Case Study Maiia Guermanova behalf of

16 Case Study Passmore Street EnerPHit Passivhaus Introduction - Page 16

17 Case Study Planning & Conservation triple glazing PassivHaus certified window Uw = 0.8W/m 2 K & Ug = 0.6W/m 2 K Passivhaus Introduction - Page 17

18 Case Study Planning & Conservation mock sashes Triple glazed mock sash Uw = 0.8W/m 2 K & Ug = 0.6W/m 2 K Passivhaus Introduction - Page 18

19 Case Study Planning & Conservation mock sashes Passivhaus Introduction - Page 19

20 Case Study Planning & Conservation exterior insulation PROPOSED REAR WALL INSULATION (Type C) RISK ASSESSMENT HAZARD RISK CONTROL MEASURE kemparol roof insulation over joist decking 4 1 joist firring FOR ALL OTHER RISKS REFER TO CONSULTANT'S RISK ASSESSMENT. SCHEDULES ALSO SEE DETAIL DRAWING WHERE REFERENCED. total build up: 150 mm total build up: 150 mm 2 BRICK SLIPS SYSTEM 3 REV DESCRIPTION DATE 2 PL_110 scale: 1/20 PROPOSED REAR WALL SECTION (roof level) 1. Do not scale this drawing. The Contractor is to verify all dimensions & conditions on site and report any discrepencies to the Architect before proceeding. 2. This drawing is to be read in conjunction with all relevant project documentation. 3. This drawing is subject to the approval of the appropriate Statutory Authorities. BRICK SLIPS SYSTEM S T U R G I S A S S O C I A T E S 5 1 total build up: 150 mm total build up: 150 mm Project : STURGIS ASSOCIATES LLP 20 Perseverance Works Hackney Road London E2 8DD (T) +44 (0) (F) +44 (0) mail@sturgis.co.uk 13/21/23/25 PASSMORE STREET 21 PASSMORE STREET - rear KEY Title : PROPOSED REAR WALL INSULATION SECTION TYPE C 1 Existing solid brick wall Scale : Date : New external aerogel insulation (total build up 150 mm) Slip mounting system fixed to insulation Brick Slip layer to match existing brickwork (25 mm) 1 PL_110 PROPOSED REAR WALL SECTION (first floor level) scale: 1/20 2 PL_110 PROPOSED REAR WALL SECTION (foundation level) scale: 1/20 A3 June 2013 Drawn by : Checked by : DLG Drawing No. : Revision : 5 New concrete cill to match existing cill appearence C1301_115_PL_ PASSMORE STREET - rear Note1: All existing features, window cills, plinths reproduced to match existing Status : PLANNING STURGIS ASSOCIATES LLP Passivhaus Introduction - Page 20

21 Case Study Planning & Conservation front door Passivhaus Introduction - Page 21

22 Case Study Loosing area using internal insulation Proposed plans Passivhaus Introduction - Page 22

23 Case Study Loosing area using internal insulation Aerogel insulation Plastic anchors Cellular glass insulation Passivhaus Introduction - Page 23

24 Case Study Loosing area using internal insulation Vermiculite/perlite chimney fill Passivhaus Introduction - Page 24

25 Case Study Loosing height ventilation ducts Posi-joists Laminated timber I-beams Passivhaus Introduction - Page 25

26 Case Study Risk of interstitial condensation Lime parge coat Intelligent membrane 80% RH Lime Parge Coat Interior Surface WUFI analysis Construction Moisture Removal RH below 80% threshold images courtesy: PassivHaus Trust Passivhaus Introduction - Page 26

27 Case Study Difficulty Achieving Airtightness Air tests every 3 weeks Continuous airtightness using red line Service zone = no penetrations images courtesy: PassivHaus Trust Passivhaus Introduction - Page 27

28 Case Study Unavoidable thermal bridges images courtesy: PassivHaus Trust Passivhaus Introduction - Page 28

29 Case Study Unavoidable thermal bridges 31 Software: Therm Date: 18/06/2014 Job Name: 11/19 Passmore Street Job No: C1301_477_300_1 20 Perseverance Works, Hackney Road, London E2 8DD Tab name: Ambient Junction (2) Completed by: MF T +44 (0) F +44 (0) W Descrip: Main Roof - rear wall junction Checked by: MG Heat Flux Data colum Row Name Ufactor name Length mm U factor L2D W/Km Black = no heat flow (Heatflow through materials) White = high heat flow! S 16 Roof External T 16 Rear wall Internal U 16 L2D Internal U - value calculation for data row Roof Check surface resistances correct Checl total length correct y y Modelling U Value ( W/m2K) U - value calculation for data row Rear wall Check surface resistance correct Checl total length correct y y Modelling U Value ( W/m2K) Psi calculation length U-value/L2D1 heat flow psi value mm W/m2K W/mK W/mK L2D Roof Length time U value: Rear wall Length time U value: psi Internal 0.06 W/mK Isotherms Cold Outside (0 C)! Psi calculation length U-value/L2D1 heat flow psi value (Lines of constant temp) mm W/m2K W/mK W/mK L2D Roof Length time U value: Rear wall Length time U value: psi External W/mK Error in calculation: From therm report - worst cell 1.4 % Warm Inside (20 C)! Junction (inc reference planes) Elements Roof Rear Wall Passivhaus Introduction - Page 29

30 Case Study Unavoidable thermal bridges Bauvorhaben: Datum: Psi-Therm 3D 3D Wärmebrückenberechnung Detail Drg 305 Detail 2 Description Double PFC / Ext Wall / Extension Roof T in calc Proposed Base Difference Chi ºK Q (W) Q (W) Q (W) (W/K) Passivhaus Introduction - Page 30

31 Case Study Quality Control Passivhaus Introduction - Page 31

32 PassivHaus Introduction Thank you! If you have any questions contact Maiia Guermanova

Single family semi-detached four-bedroom home in London, England

Single family semi-detached four-bedroom home in London, England Passivhaus Project Documentation Hiley Road Retrofit Passivhaus, London, UK Abstract Single family semi-detached four-bedroom home in London, England Building data Year of Construction 2016 0.076 Space

More information

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb http://lowenergybuildings.org.uk Project name PassivHaus Retrofit - Octavia Housing Project summary PassivHaus retrofit of a three storey solid brick Victorian terraced house in a conservation area. Produce

More information

2 x BPE studies of Passivhaus domestic projects

2 x BPE studies of Passivhaus domestic projects bere:architects 73 The Poets MuseRoad London 54A Newington N5 2SH Green T London +44(0)20 N16 7359 9PX 4503 www.bere.co.uk T +44 (0)20 7241 1064 www.bere.co.uk Building Better Buildings / UCL / Technology

More information

4.2.3 MINERGIE ORIGIN AND ORGANISATION

4.2.3 MINERGIE ORIGIN AND ORGANISATION As described earlier, the energy performance of a building is calculated and compared with the requirements for the chosen Minergie system. The calculations are then sent to a Minergie administrator who

More information

Passivhaus Projects and Benefits

Passivhaus Projects and Benefits Passivhaus Projects and Benefits Andrew T. Arthur MPH CMCIEH Arthur Associates Passivhaus not Passive House Need to make distinction between: this and this Passivhaus Standard which was developed in Germany

More information

71 kwh/(m²a) Project Documentation. 1 Abstract. Single family house in Bellbrae, Victoria, Australia. 1.1 Data of building. Year of construction

71 kwh/(m²a) Project Documentation. 1 Abstract. Single family house in Bellbrae, Victoria, Australia. 1.1 Data of building. Year of construction Project Documentation 1 Abstract Single family house in Bellbrae, Victoria, Australia 1.1 Data of building Year of construction U-value external wall 2015 Space heating 0.220 W/(m²K) 16 kwh/(m²a) U-value

More information

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target. http://lowenergybuildings.org.uk Project name Larch House, Ebbw Vale, Wales Project summary The Larch House, designed by bere:architects, is the UKs first zero carbon (code 6), low cost, Certified Passivhaus,

More information

Passivhaus Introduction

Passivhaus Introduction Passivhaus Introduction INTEGRITY BUILDINGS LIMITED 0844 809 4588 jon@integritybuildings.co.uk www.integritybuildings.co.uk 2011 Integrity Buildings Ltd WHAT IS PASSIVHAUS Passivhaus was established in

More information

D3.9_Overall Refurbishment Plan DRAFT CS03. Hotel Restaurant Valcanover

D3.9_Overall Refurbishment Plan DRAFT CS03. Hotel Restaurant Valcanover D3.9_Overall Refurbishment Plan DRAFT CS03 Hotel Restaurant Valcanover INTELLIGENT ENERGY EUROPE II Energy efficiency and renewable energy in buildings IEE/12/070 EuroPHit [Improving the energy performance

More information

Passivhaus Project Documentation Wrexham Passivhaus

Passivhaus Project Documentation Wrexham Passivhaus Passivhaus Project Documentation Wrexham Passivhaus Design/Architecture: Simmonds Mills Architects Structural ngineer: Bob Johnson Structural ngineers, Shrewsbury Building Services: Alan Clarke Passivhaus

More information

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales http://lowenergybuildings.org.uk Project name Self Heating Social Housing- the zero carbon retrofit Project summary The target for this project is to create the first UK PassivHaus retrofit using low/zero

More information

Project Description. Projected build start date 01 May 2010 Projected date of occupation 01 Nov Belfast, County Antrim, Northern Ireland

Project Description. Projected build start date 01 May 2010 Projected date of occupation 01 Nov Belfast, County Antrim, Northern Ireland http://lowenergybuildings.org.uk Project name Eco-Energy Retrofit, Grove Housing Association, Belfast Project summary The mid terrace solid wall house built in 1896, is located in North Belfast and owned

More information

Built examples and project certification. Zeno Bastian, Passive House Institute

Built examples and project certification. Zeno Bastian, Passive House Institute Built examples and project certification Zeno Bastian, Passive House Institute Passive House Standard for Retrofits? Photo Passive House Institute Shape Graphic Passive House Institute Thermal Bridges

More information

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008 Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008 Agenda European Passive House Program Creating Passive House Designs in U.S.

More information

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles http://lowenergybuildings.org.uk Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles Project Description Projected build start date

More information

Project Description. Projected build start date Projected date of occupation. Existing external wall construction.

Project Description. Projected build start date Projected date of occupation. Existing external wall construction. http://lowenergybuildings.org.uk Project name Admirals Hard Project summary FINALIST of the UK Passivhaus Awards 2015 - Situated on the Stonehouse peninsula, by the banks of the River Tamar, Number 3 Admirals

More information

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction http://lowenergybuildings.org.uk Project name Redlands Project summary Deep retrofit of 1955 brick house in Devon based on EnerPHit standard. House had old gas boiler, double glazing, cavity wall insulation

More information

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings CIBSE Technical Symposium London 2018 Thursday 12th Friday 13th April Introduction CREST since 2013 Passive House

More information

PHPP Report. Beattie Passive Inchkeith Drive

PHPP Report. Beattie Passive Inchkeith Drive PHPP Report Beattie Passive Inchkeith Drive 1. Introduction Passive House is the world-leading building standard in energy-efficient construction. It is comfortable, affordable and ecological at the same

More information

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Passiv Haus Institut. Certification as Quality Approved Passive House Criteria for Non-Residential Passive House Buildings Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings Passive Houses

More information

Project Description. Projected build start date 19 Apr 2010 Projected date of occupation 30 Sep

Project Description. Projected build start date 19 Apr 2010 Projected date of occupation 30 Sep http://lowenergybuildings.org.uk Project name LB Greenwich - How low can we go? Project summary Our project has sought to produce a retrofit solution which is practical to build, easy to run and maintain,

More information

Primary School Retrofit Project

Primary School Retrofit Project Primary School Retrofit Project Final Design Proposal Ian Black DIT D12124703 Passiv Haus Design Criteria PHI ENERPHIT CRITERIA EnerPHit Certification based on the requirement for heating demand Heating

More information

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec http://lowenergybuildings.org.uk Project name Hounslow Council Passivhaus Retrofit - and the development of a decision making matrix Project summary The house is a 3-bedroom semi-detached single-family

More information

Learnings from residential PH design and procurement in Australia. Luc Plowman

Learnings from residential PH design and procurement in Australia. Luc Plowman Learnings from residential PH design and procurement in Australia Luc Plowman Summary Stakeholder education Expectations Materials & documentation Heating & cooling Costs Documentation requirements The

More information

A prototype architecture for passive and plus energy building in Estonia

A prototype architecture for passive and plus energy building in Estonia A prototype architecture for passive and plus energy building in Estonia Tõnu Mauring, Jaanus Hallik, Margus Valge, Kristo Kalbe University of Tartu, Institute of Technology Georg W. Reinberg, Architekturbüro

More information

Project name Fulford Passivhaus, York Project summary New-build singe-family detached house for individual clients. Certified as Passivhaus Plus.

Project name Fulford Passivhaus, York Project summary New-build singe-family detached house for individual clients. Certified as Passivhaus Plus. http://lowenergybuildings.org.uk Project name Fulford Passivhaus, York Project summary New-build singe-family detached house for individual clients. Certified as Passivhaus Plus. Project Description Projected

More information

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Dienstleistung. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality

More information

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction http://lowenergybuildings.org.uk Project name Tower Hamlets - naturally ventilated Passivhaus Retrofit Project summary The property is a 3 bedroom mid terrace single family residence built in the 1960

More information

Zero Energy Building Example in Estonia. Tõnu Mauring

Zero Energy Building Example in Estonia. Tõnu Mauring Zero Energy Building Example in Estonia Tõnu Mauring University of Tartu, Estonia Jan 22 2014, Riga Site location Põlva, Estonia (58 N, 27 E) Long-term average dry bulb temperature for inland part of Estonia

More information

BRE Bites: Passivhaus Ecobuild 20 th 22 nd March 2012

BRE Bites: Passivhaus Ecobuild 20 th 22 nd March 2012 BRE Bites: Passivhaus Ecobuild 20 th 22 nd March 2012 Part of the BRE Trust What is Passivhaus? A Passivhaus may be defined as a building in which a comfortable internal temperature is achieved solely

More information

1.1 BUILDING DESCRIPTION:

1.1 BUILDING DESCRIPTION: 1.1 BUILDING DESCRIPTION: Location: 2958 Princess Ave, North Vancouver, BC Building Type: Single Family Residential - Retrofit Certification Type: EnerPHit Year of Construction: 2017 Gross Floor Area:

More information

http://lowenergybuildings.org.uk Project name Grove Cottage Project summary Extension & Refurbishment of Victorian Townhouse using Passivhaus methodology and CarbonLite guidance. Certified to the Passivhaus

More information

Project name SOLAR HOUSE 80/50 Project summary

Project name SOLAR HOUSE 80/50 Project summary http://lowenergybuildings.org.uk Project name SOLAR HOUSE 80/50 Project summary Project Description Projected build start date 01 Mar 2010 Projected date of occupation 19 Jul 2010 Project stage Under construction

More information

PASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy.

PASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy. PASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy. + Energy efficiency + Savings +Comfort WHAT IS PASSIVHAUS? The Passivhaus (Passive House) standard is the most stringent international

More information

Built for sustainability Built for the environment Built for fuel efficiency Built for life

Built for sustainability Built for the environment Built for fuel efficiency Built for life Integrity and London s first and jointly England s first Certified Passivhaus Built for sustainability Built for the environment Built for fuel efficiency Built for life Coming Soon to Cambridge the City

More information

LITTLEPITS PASSIVHAUS PLUS

LITTLEPITS PASSIVHAUS PLUS #UKPHC18 LITTLEPITS PASSIVHAUS PLUS with PH15 SYSTEM Jae Cotterell Chartered Architect & Certified Passivhaus Designer Director of Passivhaus Homes Ltd and Passivhaus Store Co-author of The Passivhaus

More information

Residential New Construction Passive House The Nordeast Nest Case Study Tim Eian, Dipl.-Ing., Certified Passive House Planner & Consultant

Residential New Construction Passive House The Nordeast Nest Case Study Tim Eian, Dipl.-Ing., Certified Passive House Planner & Consultant Residential New Construction Passive House The Nordeast Nest Case Study Tim Eian, Dipl.-Ing., Certified Passive House Planner & Consultant In accordance with the Department of Labor and Industry s statute

More information

Welsh Future Homes. Developer: United Welsh Housing Association. Project Description. Architect: bere:architects. Location: Ebbw Vale, Wales

Welsh Future Homes. Developer: United Welsh Housing Association. Project Description. Architect: bere:architects. Location: Ebbw Vale, Wales Case Study 03 Welsh Future Homes Developer: United Welsh Housing Association Architect: bere:architects Location: Ebbw Vale, Wales Building Types: Residential Community Renewable & Low Carbon Technologies

More information

Passive House. Briefing. Thurs Cork Institute of Technology Welcomes the Passive House Association of Ireland

Passive House. Briefing. Thurs Cork Institute of Technology Welcomes the Passive House Association of Ireland Passive House Briefing Cork Institute of Technology Welcomes the Passive House Association of Ireland Thurs 19.02.15 Passivhaus is an evidence-based performance standard for buildings that delivers radically

More information

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research Brittany Coughlin, RDH Building Science Inc. 224 W 8 th Ave, Vancouver, BC Canada Phone: +011 604 873 1181;

More information

EnerPHit. Criteria for Residential-Use Refurbished Buildings

EnerPHit. Criteria for Residential-Use Refurbished Buildings Passive House Institute Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de EnerPHit Certification as Quality-Approved Energy Retrofit with Passive House Components Criteria for Residential-Use

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Healthy Buildings 217 Europe July 2-5, 217, Lublin, Poland Paper ID 89 ISBN: 978-83-7947-232-1 THERMAL RETROFIT OF A RESIDENTIAL BUILDING IN ROMANIA TO REACH LOW-CONSUMPTION ENERGY TARGETS Andrei DAMIAN

More information

PASSIVE HOUSE FACT SHEET (pg 1 of 2)

PASSIVE HOUSE FACT SHEET (pg 1 of 2) PASSIVE HOUSE FACT SHEET (pg 1 of 2) INTRODUCTION The Passive House Standard is the highest building efficiency standard in the world, with the promise of reducing the energy consumption of buildings by

More information

St Loyes Extra Care Facility PHPP Pre-Assessment Report

St Loyes Extra Care Facility PHPP Pre-Assessment Report St Loyes Extra Care Facility PHPP Pre-Assessment Report Gale & Snowden Architects & Engineers July 2011 Gale & Snowden Architects St Loyes Extra Care Facility PHPP Pre-Assessment Report Page 2 of 10 St

More information

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions.

Future tree planting on the two acre lot will offset remaining lifetime carbon emissions. Luxury Net-Zero Home by Rockwood Custom Homes 47 Grandview Place, Calgary AB T3Z A8 by Grant Bremner A Net-Zero Emissions (NZE) home is carbon neutral where carbon credits fully offset emissions. An NZE

More information

Minimum Energy Consumption 84% energy heating savings*

Minimum Energy Consumption 84% energy heating savings* 3 HOUSE DESIGNS OF 140m² A modern concept for energy efficiency ENERGY EFFICIENCY AND ENVIRONMENTAL QUALITY Minimum Energy Consumption 84% energy heating savings* * According to a home fulfilling thermal

More information

Project Description. Projected build start date Projected date of occupation 01 Jun Low Energy Buildings

Project Description. Projected build start date Projected date of occupation 01 Jun Low Energy Buildings http://lowenergybuildings.org.uk Project name Knights Place Project summary When the client, Exeter City Council, was offered a funding opportunity by the HCA to develop the first council housing in Exeter

More information

PASSIVE HOUSE OBJECT DOCUMENTATION

PASSIVE HOUSE OBJECT DOCUMENTATION PASSIVE HOUSE OBJECT DOCUMENTATION Rua do Mar House B, single family house, Ílhavo Portugal (Passive House project database: ID 2403) 2.1 PROJECT OVERVIEW Project designer: João Marcelino, Homegrid (www.homegrid.pt)

More information

Project Description. Projected build start date 11 Feb 2013 Projected date of occupation 14 Nov

Project Description. Projected build start date 11 Feb 2013 Projected date of occupation 14 Nov http://lowenergybuildings.org.uk Project name Clapham Retrofit Project summary This 4-storey semi-detached Grade II listed Victorian townhouse has been eco retrofitted to a high standard of airtightness

More information

Analysis of Heating Energy of Ventilation and Underground Heat Exchanger in North European Passive Houses

Analysis of Heating Energy of Ventilation and Underground Heat Exchanger in North European Passive Houses Issue 1, Volume 6, 2012 92 Analysis of Heating Energy of Ventilation and Underground Heat Exchanger in North European Passive Houses Hendrik Voll, Erkki Seinre, Mati Sööt Abstract-- The paper is taking

More information

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES

ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES ECO-RETROFITTING VERY OLD DWELLINGS: CURRENT AND FUTURE ENERGY AND CARBON PERFORMANCE FOR TWO UK CITIES HANIYEH MOHAMMADPOURKARBASI, STEVE SHARPLES School of Architecture, University of Liverpool, Liverpool,

More information

Analysis of Heating Energy of Ventilation Systems in Non- Residental Passive Houses in Estonia

Analysis of Heating Energy of Ventilation Systems in Non- Residental Passive Houses in Estonia Analysis of Heating Energy of Ventilation Systems in Non- Residental Passive Houses in Estonia HENDRIK VOLL, INDREK RAIDE Department of Environmental Engineering Tallinn University of Technology Ehitajate

More information

EuroPHit. Outlines for training modules for designer

EuroPHit. Outlines for training modules for designer EuroPHit Outlines for training modules for designer Zeno Bastian Passive House Institute Darmstadt, Germany www.europhit.eu The EuroPHit Project With the EnerPHit Standard as the goal and Passive House

More information

SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST

SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST SOLCER HOUSE ENERGY POSITIVE - LOW CARBON - LOW COST BACKGROUND The Welsh School of Architecture has designed and built Wales first low cost energy positive house. The Solcer House is capable of exporting

More information

Passive House: Overview

Passive House: Overview Passive House: Overview Wexford Local Development Maurice Falvey MosArt Passive House Academy 3,000 BC Increasing energy standards... Conventional energy standard (65kWh/m 2 /year for space heating) Low

More information

Passive House: Overview

Passive House: Overview Passive House: Overview Wexford Local Development Maurice Falvey MosArt Passive House Academy 3,000 BC Increasing energy standards... Conventional energy standard (65kWh/m 2 /year for space heating) Low

More information

Apartment building Sodastraße 40 in Ludwigshafen, DE

Apartment building Sodastraße 40 in Ludwigshafen, DE Apartment building Sodastraße 40 in Ludwigshafen, DE PROJECT SUMMARY Renovation of an apartment building with exposed brickwork, built in 1892. 78% reduction of annual heat energy demand with interior

More information

Catalogue of Learning Targets

Catalogue of Learning Targets Appendix HW- I_EN Examination Regulations Certified Passive House Tradesperson Catalogue of Learning Targets Dr. Wolfgang Feist Rheinstr. 44 D-64283 Darmstadt www.passiv.de This catalogue of learning objectives

More information

Homesol Passive House Design Process

Homesol Passive House Design Process Homesol Passive House Design Process Passive Houses are residential, commercial and institutional buildings in which a comfortable temperature can be achieved year round with a 75% 85% reduction in energy

More information

Passive Design Solutions. Passive House The Road to Net-Zero

Passive Design Solutions. Passive House The Road to Net-Zero Passive House The Road to Net-Zero Net-Zero into the Future Net-Zero defined as producing as much energy onsite as the building uses annually. Using net-metering with the grid, so grid is acting as 100%

More information

14.8 kwh/(m²a) Project Documentation. 1 Abstract. R-951 Residence: Three Family Passive House Building. 1.1 Data of building. Year of construction

14.8 kwh/(m²a) Project Documentation. 1 Abstract. R-951 Residence: Three Family Passive House Building. 1.1 Data of building. Year of construction Project Documentation 1 Abstract R-951 Residence: Three Family Passive House Building 1.1 Data of building Year of construction U-value external wall/ U-Wert Außenwand 2013 0.112 W/(m²K) Space heating

More information

Catalogue of Learning Targets. Certified PHPP Expert

Catalogue of Learning Targets. Certified PHPP Expert Catalogue of Learning Targets Certified Expert Draft - valid as of 01.December 2018 The Passive House Institute (PHI) has extended the existing training and certification system for designers and tradespeople

More information

LISNAHULL TERRACE, DUNGANNON IRELANDS FIRST CERTIFIED SOCIAL PASSIVE HOUSING SCHEME. Case Study

LISNAHULL TERRACE, DUNGANNON IRELANDS FIRST CERTIFIED SOCIAL PASSIVE HOUSING SCHEME. Case Study LISNAHULL TERRACE, DUNGANNON IRELANDS FIRST CERTIFIED SOCIAL PASSIVE HOUSING SCHEME Five houses recently constructed at Lisnahull Terrace, Dungannon are amongst the most energy efficient homes in Northern

More information

27/10/15. Rod Hughes Architect Director 2030 architects ltd. Penrith

27/10/15. Rod Hughes Architect Director 2030 architects ltd. Penrith Rod Hughes Architect Director 2030 architects ltd. Penrith We specialise in high quality low carbon development, retrofit and community led design We often work with community groups to develop consensus

More information

Using Whole-life Costing Analysis for retrofits of low and high rise flats

Using Whole-life Costing Analysis for retrofits of low and high rise flats Technical Insight November 2015 Whole-life costs for EnerPHit: Using Whole-life Costing Analysis for retrofits of low and high rise flats Dr Sarah Price The Passivhaus certification criteria for retrofitted

More information

Building Sustainability Why Passive House?

Building Sustainability Why Passive House? Building Sustainability Why Passive House? Paul McAlister RIBA Northern Ireland s First Certified Passive House Designer Agenda Timeline to Carbon Zero Features of a Passive House How it works Benefits

More information

Project Description. Projected build start date 18 Mar 2013 Projected date of occupation 11 Nov 2013

Project Description. Projected build start date 18 Mar 2013 Projected date of occupation 11 Nov 2013 http://lowenergybuildings.org.uk Project name Coventry Eco House Project summary A project vision for Coventry & Warwickshire FORCE Group to design and build two 3 bedroom detached houses for Orbit Homes

More information

Project Description. Projected build start date 10 Sep 2012 Projected date of occupation 03 May

Project Description. Projected build start date 10 Sep 2012 Projected date of occupation 03 May http://lowenergybuildings.org.uk Project name Bristol Retrofit Project summary A full thermal retrofit of a mid-century, three-storey property built into a hill and located within a Conservation Area in

More information

Achieving the nearly zero energy building concept - A study based on practical experience

Achieving the nearly zero energy building concept - A study based on practical experience Achieving the nearly zero energy building concept - A study based on practical experience SIMON PESCARI, VALERIU STOIAN, DANIEL DAN, DAN STOIAN Department of Civil Engineering and Equipment, Faculty of

More information

Assignment 3 Integrated Energy Design

Assignment 3 Integrated Energy Design Assignment 3 Integrated Energy Design AAR4926 Marco Rimensberger Shabnam Arbab Shangyi Sun May 2012 Page 0 Contents 1 Introduction... 2 2 Background... 2 3 Design Progress... 2 3.1 Available Energy Sources...

More information

OKO House by YOUMEHESHE architects

OKO House by YOUMEHESHE architects OKO House by YOUMEHESHE architects The OKO House The OKO House is a modular pre-fabricated design aimed initially at the European and North American housing market and to be developed for other global

More information

PassivTEN - Scottish Tenements and the Passivhaus Standard

PassivTEN - Scottish Tenements and the Passivhaus Standard PassivTEN - Scottish Tenements and the Passivhaus Standard Alan Benson Milnbank HA Matt Bridgestock John Gilbert Architects Tenements stats that influenced the study.. 23% of Scottish housing stock 35%

More information

Second and Delaware, Kansas City, MO Passive House Institute US PHIUS 1

Second and Delaware, Kansas City, MO Passive House Institute US PHIUS 1 Second and Delaware, Kansas City, MO 2017 Passive House Institute US PHIUS 1 FUTURE WORLDWIDE TRANSITION 1800 1600 1400 1200 1000 800 600 400 200 energy-efficiency new geo-/ozean. power solar windpower

More information

The Passive House Institute US

The Passive House Institute US The Passive House Institute US Passive House Concept, History & Economic opportunities for the US Building Sector Katrin Klingenberg Director Passive House Institute US PHIUS ph: 217.819.7988 988 katrin@passivehouse.us

More information

Why Choose Passivhaus?

Why Choose Passivhaus? Why Choose Passivhaus? Jon Bootland Passivhaus Trust Passivhaus Trust The Foundry, 5 Baldwin Terrace, London N1 7RU Tel: 0207 704 3502 Email: info@passivhaustrust.org.uk Web: www.passivhaustrust.org.uk

More information

Energy autarkic buildings

Energy autarkic buildings Department of Mechanical and Aerospace Engineering Energy autarkic buildings Author: Athanasios Lentzios Supervisor: Dr Paul Tuohy A thesis submitted in partial fulfilment for the requirement of the degree

More information

An investigation into potential of passive solar. features to realise net zero carbon housing

An investigation into potential of passive solar. features to realise net zero carbon housing Department of Mechanical and Aerospace Engineering An investigation into potential of passive solar features to realise net zero carbon housing Author: Swapnil Sunil Kulkarni Supervisor: Professor Joe

More information

Warm climate - Passivhaus system

Warm climate - Passivhaus system Warm climate - Passivhaus system Contents ISOBIO system 3 ISOBIO standard panel 4 Panel assembly 5 Functions 7 Construction details 8 TB 01. Slab on grade - External wall 11 TB 02. Suspended floor over

More information

Cool temperate climate - Passivhaus system

Cool temperate climate - Passivhaus system Cool temperate climate - Passivhaus system Contents ISOBIO system 3 ISOBIO standard panel 4 Panel assembly 5 Functions 7 Construction details 8 TB 01. Slab on grade - External wall 11 TB 02. Suspended

More information

When the London Borough of Camden decided

When the London Borough of Camden decided 18 social housing special report Andy Matthews Photography Passivhaus is a standard for insulating buildings to such high levels that energy bills fall to a fraction of their normal cost. A development

More information

DI (FH) Dieter Herz - Herz & Lang GmbH. House of the Future

DI (FH) Dieter Herz - Herz & Lang GmbH. House of the Future DI (FH) Dieter Herz - Herz & Lang GmbH House of the Future Office Overview Overall planning old/new build Architechture + Technical planning Building measurement+ expert advice PH-Consulting + Certification

More information

Bringing German Energy Design Home (to where it all began)

Bringing German Energy Design Home (to where it all began) Intro to Passivhaus Bringing German Energy Design Home (to where it all began) Alaska, 2012 Image credit: http://spacesplacesandfaces.ca/2011/02/10/february-10-2011-canadas-first-passive-house Bronwyn

More information

Passive House Solutions Guide

Passive House Solutions Guide Passive House Solutions Guide Achieve superior energy efficiency and occupant comfort with stone wool insulation The House at Cornell Tech Photo by Field Condition Introduction Passive House is a voluntary

More information

D3.9_Overall Refurbishment Plan DRAFT CS15. André Tournon-sur-Rhône

D3.9_Overall Refurbishment Plan DRAFT CS15. André Tournon-sur-Rhône D3.9_Overall Refurbishment Plan DRAFT CS15 André Tournon-sur-Rhône INTELLIGENT ENERGY EUROPE II Energy efficiency and renewable energy in buildings IEE/12/070 EuroPHit [Improving the energy performance

More information

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design Proceedings of the 2 nd ICAUD International Conference in Architecture and Urban Design Epoka University, Tirana, Albania, 8- May 14 Paper No. 128 Passive Strategies and Low-Carbon Technologies: Evaluating

More information

Verified net Zero Energy Building with air source heat pumps for SME

Verified net Zero Energy Building with air source heat pumps for SME Verified net Zero Energy Building with air source heat pumps for SME Field measurements were conducted on a net zero energy building designed for small to medium enterprises (SMEs). Energy flow and comfort

More information

Jon Chadwick Associated Architects. Scaling Up Passivhaus The Centre for Medicine, University of Leicester

Jon Chadwick Associated Architects. Scaling Up Passivhaus The Centre for Medicine, University of Leicester Jon Chadwick Associated Architects Scaling Up Passivhaus The Centre for Medicine, University of Leicester The Centre for Medicine, University of Leicester Overview of the Client Brief: Bring together the

More information

BPE Case study of Pippin Close and Barnlea Close

BPE Case study of Pippin Close and Barnlea Close BPE Case study of Pippin Close and Barnlea Close Building Performance Evaluation conference 14 th July 2015 Woking Professor Rajat Gupta and Mariam Kapsali Low Carbon Building Group, Oxford Institute for

More information

Passive House: The Standard and its Prospects for Practical Use

Passive House: The Standard and its Prospects for Practical Use Passive House: The Standard and its Prospects for Practical Use BSMC www.bsmc.de SB08 Special Forum: Cool:Hot:Continental:Coastal The Passive House Concept in a Worldwide Perspective, Melbourne, Australia,

More information

Sustainable Building Façade and Advanced Fenestration Systems

Sustainable Building Façade and Advanced Fenestration Systems Workshop on Potential Technological Developments for Zero Carbon Buildings 16-17 Oct 2013 Sustainable Building Façade and Advanced Fenestration Systems Tin-Tai Chow Building Energy & Environmental Technology

More information

7/2/2015. Passive House in Australia. Australian Passive House Association. Australian Passive House Associate (APHA)

7/2/2015. Passive House in Australia. Australian Passive House Association. Australian Passive House Associate (APHA) Passive House in Australia Presenter: Clare Parry Baw Baw Sustainability Network on Thursday 25 th June 2015 Australian Passive House Association Australian Passive House Associate (APHA) 2 APHA is an

More information

Building Performance Evaluation

Building Performance Evaluation BUILDING PERFORMANCE EVALUATION CASE STUDY ONE BRIGHTON One Planet Living Zero carbon (renewable heat, on and off-site renewable electricity) Mechanical ventilation with heat recovery, communal heating,

More information

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season Journal of Energy and Power Engineering 9 (2015) 386-392 doi: 10.17265/1934-8975/2015.04.008 D DAVID PUBLISHING Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season Ghanim

More information

THE PASSIVE HOUSE STANDARD

THE PASSIVE HOUSE STANDARD 02.03.01 THE PASSIVE HOUSE STANDARD 02.03_PH-SUMMER SCHOOL THE PASSIVE HOUSE STANDARD Composition: Ernst HEIDUK Language support: William GALLAGHER, Rob McLEOD, Michael WILLIAMS Date: 2009-07-11 This presentation

More information

Project Description. Projected build start date Projected date of occupation. Dungannon, County Tyrone, Northern Ireland

Project Description. Projected build start date Projected date of occupation. Dungannon, County Tyrone, Northern Ireland http://lowenergybuildings.org.uk Project name Lisnahull Project summary The terrace of 5 two storey houses have been developed as the first certified social housing project in Ireland for Oaklee Homes

More information

Deep Energy Retrofit of a HighRise MURB

Deep Energy Retrofit of a HighRise MURB Deep Energy Retrofit of a HighRise MURB COLIN SHANE M.Eng., P.Eng. RDH BUILDING SCIENCES INC. SAN FRANCISCO, CA AIA Credits National Institute of Building Sciences Provider #G168 Credit(s) earned on completion

More information

EnerPHit and EnerPHit +i

EnerPHit and EnerPHit +i Passive House Institute Dr. Wolfgang Feist Rheinstraße 44/46 64283 Darmstadt Germany www.passivehouse.com EnerPHit and EnerPHit +i Certification Criteria for Energy Retrofits with Passive House Components

More information

Passivhaus and Zero Carbon

Passivhaus and Zero Carbon Passivhaus and Zero Carbon Technical briefing document 5 th July 2011 Ground Floor, 1Baldwin Terrace, London N17RU Tel: +44(0)2077043502 Email: info@passivhaustrust.org.uk Web: www.passivhaustrust.org.uk

More information

Project Description. Projected build start date 23 May 2016 Projected date of occupation 27 Feb 2017

Project Description. Projected build start date 23 May 2016 Projected date of occupation 27 Feb 2017 http://lowenergybuildings.org.uk Project name Loudon Buildings, Godinton Estate Project summary Conversion of a modern concrete framed straw barn into low energy 4 bedroom house, approved under Class Q

More information

D3.8_Evaluate Specialist Deep-Retrofit Products Report

D3.8_Evaluate Specialist Deep-Retrofit Products Report D3.8_Evaluate Specialist Deep-Retrofit Products Report DRAFT CS16, OP23, OP27 Spain INTELLIGENT ENERGY EUROPE II Energy efficiency and renewable energy in buildings IEE/12/070 EuroPHit [Improving the energy

More information