OPTICAL FIBRE CABLE PERFORMANCE

Size: px
Start display at page:

Download "OPTICAL FIBRE CABLE PERFORMANCE"

Transcription

1 TEL: FAX: Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORRUGATED STEEL TAPE CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be PRINTING DETAILS < 0.05dB/Km ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.1 Date:

2 Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km BL,OR BL,OR,GR,BR, BL,OR,GR,BR. SL,WH,RD,BK, YL,VI,PK,AQ BL,OR,GR,BR,SL,WH Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / 4 / 6 Km + 10 % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:

3 Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK OUTER SHEATH CORE WRAPPING WITH GR YARNS (If required) LOOSE TUBE WITH FIBERs AND WSY FRP CENTRAL STRENGTH MEMBER CORRUGATED STEEL TAPE WS YARNS RIPCORD(s) Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mm Installation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL ENVIRONMENTAL 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:

4 Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km RD,BK. RD,BK,YL,VI,PK,AQ. RD,BK,YL,VI,PK,AQ Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/12-F-D-S3-1-BM-TD Rev.:-1.0 Date:

5 Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm : 0.23 PMDq Loose Core Central Strength Member Filler Peripheral Strength member Core Wrapping Cable Rip Cords Armoring Outer Sheathing SM (G.652) Multi Single Jacket Armor Optical Cable PRODUCT INFORMATION 0.2 ps/ km Water Swellable Material is added to prevent water ingress in the Loose. Thermoplastic Material Reinforced Plastic to provide tensile strength and antibuckling properties. Polyethylene Water Swellable Yarns is added to prevent water ingress in the core of cable. Glass Roving Yarns (if required to meet tensile strength) Binder and Water Blocking Tape. Polyester Based Yarns applied below Sheath Corrugated Steel Tape UV Proof MDPE/HDPE CONSTRUCTIONAL DETAILS BLACK MDPE SHEATH CORE WRAPPING WITH GR YARNS (If required) CORRUGATED STEEL TAPE WS MATERIAL FRP CENTRAL STRENGTH MEMBER WATER SWELLABLE YARNS LOOSE TUBE WITH FIBERs AND WSY RIPCORD(S) OPTICAL FIBRE CABLE PERFORMANCE MECHANICAL Typical Construction Diagram - Not To Scale Max. Tensile Strength 2700N Temp. Performance Minimum Bend Radius Crush Resistance 2000 N /100x100 mminstallation -30ºC to +70ºC -During Installation 20 D Impact strength 25 Nm Operation -40ºC to +70ºC -After Installation 15 D Torsion ± 180 Storage -40ºC to +70ºC Water Penetration 1m head, 3m samples, 24 hrs All tests shall be carried out as per IEC Standards. Change in attenuation shall be < 0.05dB/Km PRINTING DETAILS ENVIRONMENTAL Printing details (White - Hot Foil Emb.) STERLITE SM Count GF ARMOR OFC Laser Symbol Telephone Symbol Year of Manufacture Cable ID FEET Marking. The accuracy of marking shall be + 0.5%., Occasional loss of printing & remarking shall be as per Bell core GR 20 and this supercedes the earlier markings. Prepared By:- N. Nitesh Approved By:- Doc. No.:- 24/12-F-D-S3-1-BM-TD Rev.:-1.0 Date: Registered Office:E, MIDC Waluj, Aurangabad , Maharashtra, INDIA.

6 Page:- 2 of 2 Count s Per SM (G.652) Multi Single Jacket Armor Optical Cable CABLE CONSTRUCTION s Fillers Color of Looses In Sequence Color Diameter of Cable (+5%) Weight of Cable (+10%) Numbers Numbers Number mm kg/km RD,BK,YL - for 1st Layer RD,BK,YL,VI,PK,AQ BL,OR,GR - for 2nd Layer BL,OR,GR,BR,SL,WH, RD,BK,YL,VI,PK,AQ Where: BL =Blue,OR =Orange, GR=Green,BR=Brown,SL=Grey(Slate), WH=White, RD=Red,BK=,YL=Yellow,VI=Violet,PK=Pink,AQ= Aqua Filler Color: Outer Sheath Color: Standard Length Details Cable length (Km) 2 / % Order Tolerance: ± 5 % Short Lengths : MAX 5 %, Customer Approval. Prepared By:- N. Nitesh Approved By:- Doc. No.:- YY/XX-F-D-S3-1-BM-TD Rev.:-1.0 Date: Registered Office:E, MIDC Waluj, Aurangabad , Maharashtra, INDIA.

Specifications of. Single Armored Optical Fiber Cable

Specifications of. Single Armored Optical Fiber Cable SPEC. NO A15022701 Sheet no.1 of 7 Date: 15-02-27 Specifications of Single Armored Optical Fiber Cable (GYFTS) 1. General SPEC.NO A15022701 Sheet No.2 of 7 1.1 This specification covers the requirements

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

FTTH Fiber Optical Cable

FTTH Fiber Optical Cable FTTH Optical Cable FTTH Drop Cables are designed to connect the fiber access point to the ONT on the home in a FTTH network. It offers an efficient and economical solution for deploying fiber in FTTH network.

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials.

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials. LightScope ZWP Single Alternative Jacket All-Dielectric, Gel-Filled, Outdoor Stranded Loose Tube Cable Product Classification Portfolio CommScope Product Type Fiber OSP cable Regional Availability Asia

More information

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials LazrSPEED Plenum Distribution Cable, 6 fiber single-unit Product Classification Portfolio CommScope Product Type Fiber indoor cable Regional Availability Asia Australia/New Zealand EMEA Latin America North

More information

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks

More information

Amphenol Spectra-Strip

Amphenol Spectra-Strip 161 Series Fiber Optic Cable for Harsh Environments 1 are subject to change without notice. Introduction Amphenol Corporation is a world leader in harsh environment Interconnect systems. The Spectra-Strip

More information

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications UGGMPMXAD Ultra Low Loss (ULL) TeraSPEED MPO (female) to MPO (male), Pre-terminated Trunk Cable, MPO12, 12-Fiber, Plenum SYSTIMAX Brand SYSTIMAX ULL TeraSPEED Fiber trunk cable assembly Regional Availability

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET METRIC MIL-PRF-85045/21 26 July 1999 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, EIGHT FIBERS, ENHANCED PERFORMANCE, CABLE CONFIGURATION TYPE 2 (OFCC), FOR SUBMARINE OUTBOARD USE ONLY (NOT FOR

More information

Generic Requirements for Optical Fiber and Optical Fiber Cable

Generic Requirements for Optical Fiber and Optical Fiber Cable Contents Generic Requirements for Optical Fiber and Optical Fiber Cable Contents Telcordia GR-20 - Documentation Information Preface... Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2

More information

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics ENERGY PROTOLON(SMK) LWL (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics Technical Data Type Type designation Approvals/ standards Application PROTOLON (SMK) LWL (N)TSKCGEWÖU DIN

More information

etwork etwork-/ethernet-/foc-cable

etwork etwork-/ethernet-/foc-cable etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet

More information

BHUTAN TELECOM LIMITED

BHUTAN TELECOM LIMITED TENDER NO. BT/Fiber Cables /2018 TERMS & CONDITIONS Bhutan Telecom invites sealed quotations from the eligible firms for the supply of Fiber Cables in Annexure I for the year 2018 subject to the following

More information

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES AS... UV-FIBERS Features Higher transmission than PCS-Fibers between 180 nm and nm High core

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension EnduraGain OSP Cable Installation Guidelines EnduraGain OSP Cable Superior Essex manufactures EnduraGain Outside Plant (OSP) cables for outdoor use in Category 5, 5e, 6 and 6A cables designs. Category

More information

RN Optical Termination Panel (RN OTP)

RN Optical Termination Panel (RN OTP) RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.

More information

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS STANDARD FOR BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568 Carrollton,

More information

Industrial Harsh Environment Fiber Cables

Industrial Harsh Environment Fiber Cables Industrial Harsh Environment Fiber Cables The Prysmian Group provides optical fiber cabling solutions designed specifically for use in industrial and harsh environments, such as, mining, aviation, transit,

More information

PLASTICS. Chapter 5. Materials of Construction-Plastics 1

PLASTICS. Chapter 5. Materials of Construction-Plastics 1 PLASTICS Chapter 5 Materials of Construction-Plastics 1 Plastics Plastics are synthetic materials which are composed of high molecular weight substances consisting of macromolecules of colloidal dimensions.

More information

The Company by Peter Bröckskes sen. an independent, middle sized company

The Company by Peter Bröckskes sen. an independent, middle sized company The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

Specialty Multimode Graded-Index Fiber

Specialty Multimode Graded-Index Fiber Specialty Fiber MM Graded-Index Fibers Fiber Name 50/125 62.5 50/125 Hermetic 50/125 Acrylate 100/140 Acrylate 100/140 High-Temp 100/140 Dual Acrylate 100/140 Unbuffered 100/140 Buffered Geo50 Core/Clad/Buffer

More information

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable

More information

Safe, efficient cable protection with high performance polymers

Safe, efficient cable protection with high performance polymers Safe, efficient cable protection with high performance polymers Evonik, the creative industrial group from Germany, is one of the world leaders in specialty chemicals. Its activities focus on the key megatrends

More information

Cables for Railway Signalling Applications General Requirements

Cables for Railway Signalling Applications General Requirements Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status

More information

Expanded Beam Optical Termini

Expanded Beam Optical Termini 8D Series & ARINC 600 Series ELIOBEAM Fiber Optic Contact Expanded Beam Optical Termini The optical connection requirement for environmentally exposed mating cycles. Robust to contamination Large beam

More information

Heat-Resistant Thin Optical Fiber for Sensing in High-Temperature Environments

Heat-Resistant Thin Optical Fiber for Sensing in High-Temperature Environments INFORMATION & COMMUNICATIONS Heat-Resistant Thin Optical Fiber for Sensing in High-Temperature Environments Kazuyuki SOHMA* and Tomoyuki HATTORI We have developed a new heat-resistant optical fiber coated

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition

ISO 1401 INTERNATIONAL STANDARD. Rubber hoses for agricultural spraying. Tuyaux en caoutchouc pour pulvérisation agricole. Third edition INTERNATIONAL STANDARD ISO 1401 Third edition 1999-12-01 Rubber hoses for agricultural spraying Tuyaux en caoutchouc pour pulvérisation agricole A Reference number ISO 1401:1999(E) ISO 1401:1999(E) Contents

More information

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU INCH-POUND MIL-DTL-24643/17F 1 October 2009 SUPERSEDING MIL-DTL-24643/17E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU This specification is approved

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm Large plastic pipe technology Large diameter pressure pipe up to DN/ID 5000 mm Powerful and designed according to YOUR specifications Large diameter pressure pipes No sagging and less wallthickness saves

More information

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable Ergon Energy Corporation Limited Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable ETS04-03-01 Specification ETS04-03-01 Ver 1 Contents 1. Purpose and Scope... 1 1.1 General...

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

Corning RC Specialty Fibers Reduced Cladding Fibers Enable Miniaturization and Device Integration

Corning RC Specialty Fibers Reduced Cladding Fibers Enable Miniaturization and Device Integration Corning RC Specialty Fibers Reduced Cladding Fibers Enable Miniaturization and Device Integration Photonic Materials PI1442 Issued: July 2005 Supersedes: August 2003 Featuring ultra-tight specifications,

More information

Best Construction Practices and Splicing for Fiber Networks

Best Construction Practices and Splicing for Fiber Networks Best Construction Practices and Splicing for Fiber Networks Simon Salamanca Sr Systems Engineer, Carrier Networks Engineering Services Corning Optical Communications 07/26/2016 Agenda 1 Cable 101 2 Splicing-

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

Product Specifications

Product Specifications Product Specifications Bedford Standard Ladders Disclaimer BEDFORD REINFORCED PLASTICS INC. disclaims liability for any personal injury, property or other damages of any nature whatsoever, whether special,

More information

Fujikura PANDA fiber products and Basics of PM fibers

Fujikura PANDA fiber products and Basics of PM fibers Fujikura PANDA fiber products and Basics of PM fibers Fiber Optics components Engineering Department Fujikura Ltd. 1 Fujikura PANDA fiber solutions Fujikura has been developing below new PANDA fibers for

More information

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF 1 Solutions That Work Eastern Wire + Conduit products provide high quality

More information

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems. PHOTOVOLTAIC CABLES Energy and Fiber Optical Cables for Solar Energy Systems. As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of

More information

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe Plastic Pipe Materials, Joining, Installation, & Other Considerations Some of the pipe that you may see? Around the late 1950 s to early 2000 s Thermoplastics Plastic Materials Must Meet: ASTM D-2513 (Thermoplastic)

More information

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning

More information

Electrical Insulating Tapes

Electrical Insulating Tapes Electrical Insulating Tapes Energy, Mining, Industrial and Contractors applications LV and MV electrical jointing and termination applications Adhesive or Self-amalgamating UV resistant Cold and weather

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100) ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society

More information

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS PROForms Specifications SECTION 06600 FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS Disclaimer BEDFORD REINFORCED PLASTICS INC. disclaims liability for any personal injury, property or other damages

More information

Ultradur (PBT) Product Range. Ultradur in the web:

Ultradur (PBT) Product Range. Ultradur in the web: Ultradur (PBT) Product Range Ultradur in the web: www.ultradur.de Ultradur (PBT ) Ultradur is BASF s trade name for its line of partially crystalline saturated polyesters. This line is based on polybutylene

More information

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This

More information

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) SECTION 271400 BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) These specifications guidelines detail the intents of KCTCS for Telecommunications Infrastructure Design and Installation.

More information

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv K-LINE INSULATORS LIMITED Catalogue TD-IPS TORONTO, ONTARIO, CANADA TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission &

More information

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy Approved as an American National Standard ANSI Approval Date: June 10, 2014 ANSI/NEMA WC 71 ICEA S-96-659-2014 Nonshielded Cables Rated 2001-5000 V for Use in the Distribution of Electric Energy Prepared

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-2 Second edition 2005-03 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 2: Cables

More information

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal) ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or

More information

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,

More information

SURFACE TEMPERATURE SENSORS

SURFACE TEMPERATURE SENSORS SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such

More information

OPTICAL FIBER SOLUTIONS

OPTICAL FIBER SOLUTIONS www.ofsoptics.com/medical OPTICAL FIBER SOLUTIONS FOR YOUR MEDICAL DEVICE ISO 9001 and 13485 Certified FDA Good Manufacturing Practices USP Class VI and ISO10993 for Biocompatibility Low Bioburden Assembly

More information

Reeling Cables www.sab-worldwide.com THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business

More information

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641

More information

TORAY RAYTELA Structure Product

TORAY RAYTELA Structure Product 1 2 TORAY RAYTELA Structure Product 1. Fiber Cladding 2. Cord A. Simplex B. Duplex Fiber 3. Cable A. Simplex B. Duplex Tension Member Cord 4. Light Guide Fiber KE1619-PC6 3 4 TORAY RAYTELA Structure PE

More information

Experience and a History in Construction Products

Experience and a History in Construction Products BDI1004-Brochure 12/14/06 8:41 AM Page 2 Experience and a History in Construction Products Accessory Products. Although Blue Diamond Industries was established in 2004, the management team has experience

More information

High Performance Plastics for Wind Turbine Engineering

High Performance Plastics for Wind Turbine Engineering High Performance Plastics for Wind Turbine Engineering 05/2010 Thermoplastics Fiber reinforced plastics Röchling world leader in engineering plastics Your international supplier of technical products As

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

Lahti Precision Fluidization

Lahti Precision Fluidization Lahti Precision Fluidization The Lahti Precision fluidization technology Equipment for optimum discharge and transportation The core idea of CONVENTIONAL fluidization system is quite simple: the friction

More information

FIBER OPTIC PROJECT IMPLEMENTATION

FIBER OPTIC PROJECT IMPLEMENTATION FIBER OPTIC PROJECT IMPLEMENTATION Fiber Project Management [Draw your reader in with an engaging abstract. It is typically a short summary of the document. When you re ready to add your content, just

More information

NPS/002/023 Technical Specification for 132kV Power Cables.

NPS/002/023 Technical Specification for 132kV Power Cables. Version:- 2.2 of Issue:- June 09 Page 1 of 11 NPS/002/023 Technical Specification for 132kV Power Cables. 1. Purpose The purpose of this document is to detail the technical requirements of Northern Powergrid

More information

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00. To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

1 The Eldon James Flexelene TM tubing combines the excellent inert qualities of polyethylene with the flexibility found in 78A durometer PVC tubing. F

1 The Eldon James Flexelene TM tubing combines the excellent inert qualities of polyethylene with the flexibility found in 78A durometer PVC tubing. F 1 The Eldon James Flexelene TM tubing combines the excellent inert qualities of polyethylene with the flexibility found in 78A durometer PVC tubing. Flexelene TM is manufactured without the use of plasticizers,

More information

High Performance Plastics for the Chemical Processing Industry

High Performance Plastics for the Chemical Processing Industry High Performance Plastics for the Chemical Processing Industry 8/2017 Thermoplastics Areas of application Steel pickling Plants Over the last two decades, polypropylenes have become a more common solution

More information

SECTION HORIZONTAL CABLING

SECTION HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY SCOPE OF WORK SECTION 25160 HORIZONTAL CABLING 1. Horizontal cabling is the portion of the cabling system that extends from the work area to the Telecommunications Room or

More information

catalog Copper Wires

catalog Copper Wires catalog Copper Wires ASWire Aerial Service Wire Self Supporting Multi-pair Pair Count 1-18P Multi-pair, self-supporting Aerial Service Wires (ASW) are used for subscriber lines in exchange plant; single-pair

More information

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP. Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP. Mohit Jaiswal Assistant Professor, Department of Civil

More information

ASME B31.3 Process Piping

ASME B31.3 Process Piping ASME B31.3 Process Piping Charles Becht IV, PhD, PE Don Frikken, PE Instructors BECHT ENGINEERING COMPANY, INC. Nonmetallic Piping - 1 Piping Development Process 1. Establish applicable system standard(s)

More information

International Thermocouple and Extension Grade Wire Color Codes

International Thermocouple and Extension Grade Wire Color Codes International Thermocouple and Extension Grade Wire Color Codes ANSI Code Alloy Combination + Lead - Lead Color Coding Thermocouple Extension Grade Grade Maximum Useful Range ++ Maximum Thermocouple Grade

More information

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE OSNALINE Tubes and tube bundles KME Germany AG & Co. KG OSNALINE [GB] Member of the KME Group KME Germany AG & Co. KG Experts in tube bundles KME Germany AG & Co. KG is a member of the KME Group S.p.A.

More information

Polyethylene (HDPE) Thin Wall Containers

Polyethylene (HDPE) Thin Wall Containers Polyethylene (HDPE) Thin Wall Containers For purposes of this design guidance document, thin walled packaging, also known as thin walled containers, are rigid plastic packaging with a wall thickness less

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY

Technical Data Sheet. Cellular Buffers CONTENTS. Order number 018xxxx-xxxY 08xxxx-xxxY CONTENTS Page General information...2 2 Examples of application...2 3 Conductix-Wampfler standard cellular buffer quality...2 4 Quality degrees...3 5 Construction...4 5. With base plate...4

More information

WEIR PLATES & SCUM BAFFLES

WEIR PLATES & SCUM BAFFLES WEIR PLATES & SCUM BAFFLES Bedford Reinforced Plastics Weir Plates and Scum Baffles are available in any SIZE, any LENGTH and any CONFIGURATION Benefits Corrosion Resistant Maintenance Free Strong Easy

More information

Series K7130 Heavy Wall PVC Transfer Hose. Compound hardness 73 ±3 Shore A. Self-extinguishing. Non-marking, non-toxic and silicone-free.

Series K7130 Heavy Wall PVC Transfer Hose. Compound hardness 73 ±3 Shore A. Self-extinguishing. Non-marking, non-toxic and silicone-free. PVC HOSE Series K0 Heavy Wall PVC Transfer Hose Applications Industrial vacuum pumps and lines Food & beverage dispensing. Car wash applications. Coolant and air breathing lines. Deionized water systems.

More information

High Durability Cables Cordsets for use in extreme conditions in manufacturing

High Durability Cables Cordsets for use in extreme conditions in manufacturing High Durability Cables Cordsets for use in extreme conditions in manufacturing Connectivity s Cordsets for use in extreme conditions in manufacturing High Durability Cables Every manufacturer has challenges,

More information

FIBERGLASS HANDRAIL & LADDER SYSTEMS

FIBERGLASS HANDRAIL & LADDER SYSTEMS FIBERGLASS HANDRAIL & LADDER SYSTEMS Fiberglass Handrail Systems SAFRAIL system in a chemical plant. Internal connections make circular handrail systems such as these possible around tanks. SAFRAIL fiberglass

More information

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) Installation Manual 1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated

More information

ERTALON Extruded Products

ERTALON Extruded Products ERTALON Extruded Products Polyamides (PA) Main Characteristics: High mechanical strength, stiffness, hardness and toughness Excellent resilience High mechanical damping ability Good sliding properties

More information

Military Specifications

Military Specifications Military Specifications *MIL-P-77 *MIL-P-78A MIL-P-79C MIL-W-80C MIL-I-631D MIL-I-742C *MIL-P-997C MIL-P-997D Cast Polyester or Diallylpthlalate Sheet and Rod Engraving Stock Rigid Laminated Sheet Thermoset

More information

Military Specifications

Military Specifications Military Specifications *MIL-P-77 *MIL-P-78A MIL-P-79C MIL-W-80C MIL-I-631D MIL-I-742C Cast Polyester or Diallylpthlalate Sheet and Rod Engraving Stock Rigid Laminated Sheet Thermoset Rod & Tube, Melamine

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

SPR-54 Series. Data Sheet. Outline. Features. Viewing angle 2θ 1/2 : 45. Recommended Solder Pattern. Dimensions. Specifications. 1/ Rev.

SPR-54 Series. Data Sheet. Outline. Features. Viewing angle 2θ 1/2 : 45. Recommended Solder Pattern. Dimensions. Specifications. 1/ Rev. Features Outline Viewing angle 2θ 1/2 : 45 Color Type M V Dimensions Recommended Solder Pattern 1.0 ±0.1 2.0 2.5 2.5 Tolerance : 0.2 (unit : mm) (unit : mm) Specifications Viewing angle 2θ 1/2 / 45 :Standard

More information

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual Dome Heat Shrinkable Seal Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual 1. Scope of application This Installation Manual suits for the Optic Splice Closure (Hereafter abbreviated as FOSC),

More information

Super Low-Loss, Super High-Density Multi-Fiber Optical Connectors

Super Low-Loss, Super High-Density Multi-Fiber Optical Connectors by Katsuki Suematsu *, Masao Shinoda *, Takashi Shigenaga *, Jun amakawa *2, Masayoshi Tsukamoto *2, oshimi Ono *3 and Takayuki Ando *3 Optical connectors will be a key element in configuring large-scale

More information

Single-Jacketed Tubing

Single-Jacketed Tubing Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress

More information

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version) M Fire Barrier Duct Wrap + Product Data Sheet and Installation Guide (Condensed Version) FIRE BARRIER UP TO Fire Protection HOUR FLEXIBLE WRAP GREASE & AIR DUCT Fire Protection. Product Description M Fire

More information

SECTION WIRES AND CABLES

SECTION WIRES AND CABLES SECTION 16120 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the supply and installation of wires and cables and the associated

More information