Determination of the sound reduction and sound absorption of a railroad noise barrier
|
|
- Wilfred Nichols
- 6 years ago
- Views:
Transcription
1 TEST REPORT No. VTT-S October 29, 2014 Determination of the sound reduction and sound absorption of a railroad noise barrier Requested by: Soundim Oy
2 TEST REPORT No. VTT-S (3) Requested by Order Contact person Soundim Oy Pakkaskuja Vantaa by Jukka Näräkkä / confirmation of order VTT-O VTT Expert Services Ltd Veijo Sivonen P.O. Box 1001, FI VTT, Finland Tel , Fax veijo.sionen@vtt.fi Task Determination of the airborne sound insulation and sound absorption of railroad noise barrier Structure of the Photos of the measurements and the structure and details of the noise barrier specimen are show in Appendix 2. Date and place of testing Installation and measuring The sound insulation of the noise barrier was tested and sound absorption was tested by the personnel of VTT Expert Services Ltd at VTT Expert Services Ltd:s research hall 1. The airborne sound insulation test specimen was installed by VTT Expert Services Ltd:s personnel into the measurement opening (with dimensions 1210 x 1030 mm) between two reverberation rooms. The sound absorption test specimen (with size 3 m x 4 m) was installed client onto the floor of a reverberation room KH 3. The airborne sound reduction index of the specimen was determined by means of two-channel sound pressure level measurement with two fixed sources and moving microphones. The measurement we carried out by Technical Expert Veijo Sivonen. Method and equipment The sound reduction index R was measured in accordance with EN ISO : in one third octave bands and the single number rating DL R and categorisation was determined in accordance with EN and EN and 3. Sound insulation of the barrier was measured specimen area, which was smaller than that 12 m 2 provided by the standard. It can be approximated that the sound reduction index of the smaller specimen is a baud 2 db higher than that of specimen with area of 12 m2. However, this has no effect on the achieved classification.
3 TEST REPORT No. VTT-S (3) Sound absorption and sound absorption coefficients Si in one third octave bands were measured according to standard EN The single number rating DL and categorisation was determined in accordance with EN Reverberation room dimensions and measuring equipment are presented in Appendix 3. Results The individual measuring result are presented in Appendix 1. The categorisation of the railroad noise barrier is as follows: Noise barrier Aluminium frame / insulation (Evona 36 kg/m 2 ) / metal cladding Sound insulation Sound absorption DL R db(a) Category DL α Category 30 B3 13 A4 Espoo October 29, 2014 Pekka Sipari Senior Expert Veijo Sivonen Technical Expert VTT Expert Services Ltd. is notified body No. NB FINAS Finnish Accreditation Service has accredited our laboratory (T001, VTT Expert Services Ltd) to perform the tests mentioned.
4 TEST REPORT No. VTT-S (3) Appendices Appendix 1 Results Appendix 2 Structure of the noise barrier and photos from measurements Appendix 3 Reverberation rooms and equipments Distribution Customer Original Archive Original References [1] EN ISO :2010 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 2: Laboratory measurements of airborne sound insulation of building elements 2 EN Road traffic noise reducing devices. Test method for determining the acoustic performance. Intrinsic characteristics of airborne sound insulation 3 EN Road traffic noise reducing devices. Test method for determining the acoustic performance. Normalized traffic noise spectrum 4 EN ISO 354 Acoustics - Measurement of sound absorption in a reverberation room 5 EN Road traffic noise reducing devices. Test method for determining the acoustic performance. Intrinsic characteristics of sound absorption
5 Sound reduction index, R, db TEST REPORT No. VTT-S APPENDIX 1 1 (2) Results sound insulation Client: Soundim Oy Product identification: Railroad noise barrier Vantaa Aluminium frame / insulation (Evona 36 kg/m2) / metal cladd Test specimen mounted by: VTT Expert services Oy Date of test: Areas of test specimen: 1,3 m² Air temp. in the test rooms: 21 C Air humidity in the test rooms: 46 % Source room volume: 102 m³ Receiving room volume: 131 m³ Frequency range acording to the curve of reference values ISO Frequency One-third f octave Hz db 50 20, , , , , , , , , , , , , , , , , , , , , Frequency f, Hz Rating according to ISO 717-1: According to EN and EN1793-3: R w (C ;C tr ) = 36 (-2 ; -6) db; DL R = 30 db(a) CATEGORY: B3 Evaluation based on laboratory measurement results obtained by an engineering method
6 Absorption coefficient s (ISO 354:1985) TEST REPORT No. VTT-S APPENDIX 1 2 (2) Determination and classification of sound absorption Customer: Soundim Oy Pakkaskuja 1, Vantaa Reverberation room: Order: Jukka Näräkkä Volume : 201 m 3 Surf. area: 209 m 2 Test site: VTT/TH1 Otaniemi Sample: 12,1 m 2 Date of test: Temperature and relative humitidy: Commission: Determination and classification of absorption coefficient Empty 21 C 59 % (ISO , E and EN :1998) Sample 21 C 59 % Specimen: Area: Mass: Installation: Railroad noise barrier: aluminium frame / insulation (Evona 36 kg/m2) / metal cladding 12,1,8 m2 60 kg/m2 Sample on the floor RESULTS: 1,2 1 0,8 0,6 0,4 0, Frequency (Hz) Freq. T 1 T 2 S (Hz) (s) (s) 100 4,86 2,27 0, ,21 2,47 0, ,43 2,12 0, ,10 1,95 0, ,25 1,90 0, ,06 1,93 0, ,37 1,80 0, ,46 1,74 0, ,79 1,73 0, ,02 1,73 1, ,04 1,77 0, ,73 1,74 0, ,23 1,66 0, ,83 1,59 0, ,51 1,53 0, ,03 1,49 0, ,57 1,42 0, ,15 1,31 0,80 DL = 13 Class A4
7 TEST REPORT No. VTT-S APPENDIX 2 1 (3) Structure of the noise barrier and photos from measurement
8 TEST REPORT No. VTT-S APPENDIX 2 2 (3)
9 TEST REPORT No. VTT-S APPENDIX 2 3 (3) Photo 1. Airborne sound measurement Photo 2. Absorption measurement
10 TEST REPORT No. VTT-S APPENDIX 3 1 (1) Measuring equipment and reverberation room dimensions / Sound insulation Measuring equipment Name Serial No. Condenser microphone B&K (Brüel&Kjær) Condenser microphone B&K (Brüel&Kjær) Microphone preamplifier B&K Microphone preamplifier B&K Rotating microphone boom B&K Rotating microphone boom B&K Power amplifier Yamaha MX-1000 Loudspeakers Sinmarc V121L Real-time analyser Norsonic Sound calibrator B&K Reveberation room dimensions Floor Height Volume Source room KH1 4.7 m x 5.8 m 3.7 m 102 m 3 Receving room KH2 5.0 m x 6.5 m 4.0 m 131 m 3 Thickness of the concrete walls, floors and ceilings of the reverberation rooms is 0.25 m Measuring equipment and reverberation room dimensions / Sound absorption Measuring equipment Name Serial No. Condenser microphone B&K (Brüel&Kjær) Microphone preamplifier B&K Rotating microphone boom B&K Power amplifier Peavey PV 2600 Loudspeakers Sinmarc V121L Real-time analyser Norsonic Sound calibrator B&K Reveberation room dimensions Floor Height Volume Reveberation room KH m x 7.20 m 4.70 m 201 m³ Thickness of the concrete walls, floors and ceilings of the reverberation rooms is 0.25 m
Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO )
Reference no. T1638-1 Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO 10140 3) AUCKLAND UNISERVICES LIMITED a
More informationEvidence of Performance Joint sound reduction of filling material
Evidence of Performance Test Report No. 13-002455-PR01 (PB Z6-K02-04-en-01) ift Rosenheim 13.09.2013 Client Soudal N. V. Everdongenlaan 18-20 2300 Turnhout Belgium Product Designation Thickness of sealant
More informationLABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF PIR ROOF PANELS (According to ISO )
Ref no: LABORATORY MEASUREMENT OF AIRBORNE SOUND INSULATION OF PIR ROOF PANELS (According to ISO 10140 2) AUCKLAND UNISERVICES LIMITED a wholly owned company of THE UNIVERSITY OF AUCKLAND Report prepared
More informationKINETICS NOISE CONTROL TEST REPORT #AT001110
KINETICS NOISE CONTROL TEST REPORT #AT001110 KINETICS NOISE CONTROL PRODUCTS: o NONE ACOUSTICAL RATINGS: o STC 53 o IIC 29 TESTING AGENCY & REPORT NUMBER: o NRC-CANADA o REPORT NO. A1-010601.1 o DATED:
More informationLABORATORY MEASUREMENTS OF THE SOUND REDUCTION INDEX ROCKWOOL ABLATIVE COATED BATTS
eport No. L/3132 Page 1 of 10 for ockwool UK Limited Pencoed Bridgend CF35 6NY Dated: 30 November 2009 LABOATOY MEASUEMENTS OF THE SOUND EDUCTION INDEX OF OCKWOOL ABLATIVE COATED BATTS eport Author: M
More informationEvidence of Performance Airborne sound insulation of building components
Evidence of Performance Airborne sound insulation of building components Test Report No. 14-000251-PR01 (PB Z09-H01-04-en-02) Client Product Designation PRESS GLASS SA Nowa Wies Kopalniana 9 42-262 Poczesna
More informationASTM E 90-09: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements
ASTM E 90-09: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements 1 of 7 TEST : Acoustical Surfaces, Inc. Report Date: May 25, 2011 Test Date: September 28, 2010 Test
More informationKINETICS NOISE CONTROL TEST REPORT #AT001021B
KINETICS NOISE CONTROL TEST REPORT #AT001021B KINETICS NOISE CONTROL PRODUCTS: o ICW ACOUSTICAL RATINGS: o STC 76 o IIC 62 TESTING AGENCY & REPORT NUMBER: o NRC-CANADA o B3463.13 KINETICS DRAWING NUMBER:
More informationKINETICS NOISE CONTROL TEST REPORT #AT001067
KINETICS NOISE CONTROL TEST REPORT #AT001067 KINETICS NOISE CONTROL PRODUCTS: o FLM- NEOPRENE PAD ACOUSTICAL RATINGS: o STC 69 o IIC 61 TESTING AGENCY & REPORT NUMBER: o NATIONAL RESEARCH COUNCIL OF CANADA
More informationEvidence of Performance Joint sound reduction of filling material
Evidence of Performance Test Report No. 13-002455-PR02 (PB-K05-04-en-01) ift Rosenheim 10.09.2013 Client Soudal N. V. Everdongenlaan 18-20 2300 Turnhout Belgium Product Designation Density Special features
More informationTesting Procedure: AS ISO
RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON
More informationClassification report Airbourne sound insulation of building elements
Classification report Airbourne sound insulation of building elements Test report 161 32407/Z9e*) *) This is a translation of the test report No. 161 32407/Z9 dated 9 th October 2006 Client Reynaers Aluminium
More informationTHE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2
Concrete Centre Limited The Frame Residential Development, Sport City, Manchester Sound Insulation Test Report 2 August 2005 PROJECT: CLIENT: The Frame Residential Development, Sportcity, Manchester Concrete
More informationTEST REPORT NO
Istituto Giordano S.p.A. Via Rossini, 2-47814 Bellaria-lgea Marina (RN) - Italy Tel. +39 0541 343030 - Fax +39 0541 345540 istitutogiordano@giordano.it - www.giordano.it Cod. Fise./ Riva 00 549 540 409
More informationTesting Procedure: AS ISO
RMIT University Building 1 Level 1 Room 1 124 La Trobe Street Melbourne VIC 3000 Australia GPO Box 2476V Melbourne VIC 3001 Australia Tel. +61 3 9925 2000 Fax +61 3 9925 2000 www.rmit.edu.au REPORT ON
More informationKINETICS NOISE CONTROL TEST REPORT # AT001084
KINETICS NOISE CONTROL TEST REPORT # AT001084 KINETICS NOISE CONTROL PRODUCTS: o MODEL ISOGRID ACOUSTICAL RATINGS: o STC 63 o IIC 50 TESTING AGENCY & REPORT NUMBER: o NRC-CNRC o B-3463.6 KINETICS DRAWING
More informationKINETICS NOISE CONTROL TEST REPORT #AT001035
KINETICS NOISE CONTROL TEST REPORT #AT001035 KINETICS NOISE CONTROL PRODUCTS: o RIM I-2-16 ACOUSTICAL RATINGS: o STC 66 o IIC 63 TESTING AGENCY & REPORT NUMBER: o NRC-CANADA o B-3140.1 KINETICS DRAWING
More informationReport Number BTC 13236A
The Building Test Centre British Gypsum Limited East Leake Loughborough Leics. LE12 6NP Tel (0115) 945 1564 Fax (0115) 945 1562 email btc.testing@bpb.com Report Number BTC 13236A ACOUSTIC TEST REPORT COVERING
More informationAnalysis Joint sound insulation of filler materials
Analysis Joint sound insulation of filler materials Testing Report 167 43780/Z2 Basis ift regulation SC-01 determination of joint sound insulation degree of 2002 Diagram Applicant Hanno-Werk GmbH & Co.
More informationSignatures are required on this document for an official laboratory test report. Copies of this document without signatures are for reference only.
ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements ASTM E 492: Laboratory Measurement of Impact Sound Transmission through Floor- Ceiling Assemblies Using
More informationEvidence of Performance Joint sound reduction of filling material
Evidence of Performance Joint sound reduction of filling material Test report 167 41891/1e*) *)This is a translation of the test report 167 41891/Z1 dated 8 October 2009 Client VBH Holding AG Siemensstr.
More informationFaçade sound insulation of residential houses within Hz
Façade sound insulation of residential houses within 5 00 Hz Jukka Keränen, Jarkko Hakala, Valtteri Hongisto Turku University of Applied Sciences, Indoor Environment, Finland. Summary Health-based regulations
More informationImportant Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA
Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure
More informationImportant Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA
Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure
More informationBELLOTI, S.p.a. Via San Francesco, Cermenate (CO) - ITALY TEST REPORT
LGAI Technological Center, S.A. Campus de la UAB Ronda de la Font del Carme, s/n E - 08193 BELLATERRA (Barcelona) T +34 93 567 20 00 F +34 93 567 20 01 www.appluslaboratories.com 9/LE766 Bellaterra: 27th
More informationReport. Laboratory for Acoustics Determination of the insertion loss or sound power insulation of Arma-Chek Sound Insulation
Report Member ONRI ISO-9001: 2000 certified Laboratory for Acoustics Determination of the insertion loss or sound power insulation of Arma-Chek Sound Insulation Report number A 1395-3E dd. 4 February 2005
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: St. Louis, MO. Sound Absorption CONDUCTED: 2015-04-08 Page 1 of 7 ON: Acoustical Wrapped Panel(AWP) - 2 Inch Truetone with Polyester Svelte Face TEST METHOD Riverbank Acoustical Laboratories is accredited
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 5.1 INCLUSION OF DAMPING
More informationTEST REPORT. Report Number : / Report Date : 27 / 07 / 2015
TEST REPORT Report Number : 060.416.1 / 2015 Report Date : 27 / 07 / 2015 Testing Reference Product Client : TS EN ISO 10140-2 Acoustics - Laboratory Measurement of Sound Insulation of Building Elements
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: Margate, FL. Sound Absorption CONDUCTED: 2015-09-15 Page 1 of 7 ON: Micro-Perforated Acoustical Aluminum Ceiling Tile with SoundTex - #MPA-1 TEST METHOD Riverbank Acoustical Laboratories is accredited
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: St. Louis, MO. Sound Absorption CONDUCTED: 2015-02-19 Page 1 of 7 ON: 1" Truetone Acoustical Wrapped Panels (On 1/8" Spacers) TEST METHOD Riverbank Acoustical Laboratories is accredited by the U.S.
More informationNOISE BARRIER AT WELDING WORKPLACE
NOISE BARRIER AT WELDING WORKPLACE Janusz Piechowicz AGH University of Science and Technology, Cracow, Poland email: piechowi@agh.edu.pl Jakub Piechowicz KFB Polska Sp. z o.o., Wrocław, Poland, email:
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: AcoustiMac, LLC Tampa, FL. Sound Absorption CONDUCTED: 2015-09-14 Page 1 of 9 ON: Sound Lock/Space Divider/Partition - Wood Framed Sound Proofing Panel - Fabric Both Sides TEST METHOD Riverbank Acoustical
More informationE R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90 Rendered to: PAC INTERNATIONAL, LLC TYPE: Wall, Steel (0.018" / 25 ga), RSIC-V, STC 67 DATA FILE NO: E4748.01A STC 67 OITC 56 Test Specimen Identification: (Source
More informationC R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to Series/Model: Base 10 Specimen Type: Floor/Ceiling Assembly Overall Size: 3023 mm by 3632 mm Summary of Test Results Data File Result
More informationE R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E Rendered to REGUPOL AMERICA
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E 2179 Rendered to REGUPOL AMERICA Series/Model: Regupol 6 mm SonusWave Impact Sound Underlayment Specimen Type: Concrete Slab - 152 mm Overall Size:
More informationWhite Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Resistance to the passage of sound
White Paper. A guide to the acoustic performance of Smarts Systems Products. Building Regulations Document E Smart Systems Ltd. January 2007 Contents Building Regulations...4 Acoustic Performance - Overview...5
More informationCONDUCTED: 26 November 2013 Page 1 of 6
FOR: Audimute Soundproofing Beachwood, OH Sound Absorption CONDUCTED: 26 November 2013 Page 1 of 6 ON: Audimute Isolé Plus External Barrier Sheet TEST METHOD The test method conformed explicitly with the
More informationVTT Technical Research Centre of Finland VTT GROUP 2017 Place for a photo (no lines around photo) Mikko Nyman VTT Expert Services Ltd
VTT Technical Research Centre of Finland VTT GROUP 2017 Place for a photo (no lines around photo) 24.4.2017 Mikko Nyman VTT Expert Services Ltd VTT Technical Research Centre of Finland Ltd 75 years experience
More informationE R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to SENECA RADIANT TECHNOLOGIES
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to SENECA RADIANT TECHNOLOGIES Series/Model: Floor/Ceiling Assembly Specimen Type: Dimensional Lumber - 2x10 Overall Size: 3023 mm by
More informationE R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: GAMCO CORPORATION. Series/Model: CW250
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90 Rendered to: GAMCO CORPORATION Series/Model: CW250 Type: Two-Lite Curtain Wall System Summary of Test Results Data File No. Glazing (Nominal Dimensions) STC
More informationASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door
ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT Rendered to: THERMA-TRU DOORS SERIES/MODEL: Slimline TYPE: 8/0 Sliding Patio Door Summary of Test Results ATI Data File No. Glazing (Nominal Dimensions) STC
More informationKINETICS NOISE CONTROL TEST REPORT #AT001108
KINETICS NOISE CONTROL TEST REPORT #AT001108 KINETICS NOISE CONTROL PRODUCTS: o 1 RIM ACOUSTICAL RATINGS: o ATSC 49 o FIIC 48 TESTING AGENCY & REPORT NUMBER: o ACENTECH, INC. o PROJECT NO. 619530 o DATED:
More informationSound Insulation for Glass and Panel
SEMINAR ON TESTING AND CERTIFICATION OF GREEN CONSTRUCTION MATERIALS Sound Insulation for Glass and Panel Ir Dr CHONG Fan HIGHLIGHTS 1. Sound insulation of building construction 2. Sound insulation tests
More information-Letter - Tables 1 and 2 - Figure 1 - Exhibits 1 through 6
213-93 May 29, 213 Mr. Doug Spear, Inc. 29 Rodd St. #2847 Midland, MI 48641 Subject: Sound Transmission Loss Results of Five Test Samples, Inc. Initial tests Pre-paid Dear Mr. Spear: At your request, (K&SE)
More informationSound Insulation Test Easterton of Duntelchaig, Farr, Inverness, IV2 6AW
10 Colinton Road Edinburgh, EH10 5DT T:0845 062 0000 F: 0131 455 2563 E: rmp@napier.ac.uk I: w w w.rmp.biz BRIEF FOR CONSULTANCY: To assess the level of sound insulation of the party wall in the new build
More informationIAC Acoustics Noise-Foil Sound Absorption Panels for Industrial Applications. Dan O Brien
IAC Acoustics Noise-Foil Sound Absorption Panels for Industrial Applications Presented by Dan O Brien Industrial Business Unit Manager IAC Acoustics, A Division of Sound Seal 401 Airport Road North Aurora,
More informationCONDUCTED: 26 November 2013 Page 1 of 6
FOR: Audimute Soundproofing Beachwood, OH Sound Absorption CONDUCTED: 26 November 2013 Page 1 of 6 ON: Rigid eco-c-tex 2' x 2' Ice Cube Audimute Acoustic Coating TEST METHOD The test method conformed explicitly
More informationASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Polyvinyl Chloride (PVC)
ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT Rendered to: MI WINDOWS AND DOORS, LLC SERIES/MODEL: 1650 Polyvinyl Chloride (PVC) This product also is labeled under the following Series/Model names: 1555,
More informationRainfall and impact noise measurements on metal roof tiles
Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / Netherlands Organisation for Applied Scientific Research TNO report DGT-RPT-040015 Rainfall and impact noise measurements on metal
More informationACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR. Dr. M.Abd El Gawad Saif
ICSV14 Cairns Australia 9-12 July, 2007 ACOUSTICAL TREATMENT OF EMERGENCY POWER GENERATOR Dr. M.Abd El Gawad Saif Housing & Building National Research Center, Dokki, Giza, Egypt msaifeldin2002@yahoo.com
More informationE R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90 Rendered to: THERMA-TRU CORPORATION Series/Model: 3/0 x 6/8 Fiber-Classic/Smooth-Star, Full Lite 1" IG Impact Glass with BTS Lite Frame Type: Side-Hinged Single
More information600 Series 56 STC. Results Apply to 600 Series; Individual and Pairs. Quentin J. Schrader. Lab Code: /17/2014
UNCLASSIFIED HUFCOR TEST NO.: A1406663 Hufcor Testing Facilities P.O. Box 591 2101 Kennedy Rd. Janesville, WI 53547 USA 600 Series 56 STC Results Apply to 600 Series; Individual and Pairs Quentin J. Schrader
More informationReport. Draft. Laboratory for Acoustics
Report Member ONRI ISO-9001: 2000 certified Draft Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of a suspended ceiling type Luxalon 80B and Derako Wooden Grills,
More information148th MEETING OF THE ACOUSTICAL SOCIETY OF AMERICA November 15-19, 2004 (San Diego, California, USA)
1/11 148th MEETING OF THE ACOUSTICAL SOCIETY OF AMERICA November 15-19, 2004 (San Diego, California, USA) S-Shaped Glass also stands for Soundless Sound Insulation measurements and implication for building
More informationACOUSTIC DESIGN OF THE AUDITORIUM IN THE CHURCH OF RISPESCIA
ACOUSTIC DESIGN OF THE AUDITORIUM IN THE CHURCH OF RISPESCIA Sergio Luzzi and Lucia Busa Vie en.ro.se. ingegneria, Via Stradivari, 19, 50127 Florence, Italy email: sergio.luzzi@vienrose.it The authors
More informationFLOOR CEILING ASSEMBLY
FLOOR CEILING ASSEMBLY DIRECT FIX TO I JOIST FCW-ATI-E6968.08 CONSTRUCTION Sheet Vinyl Ecore Forest FX Plywood 5/8" Waterproof Membrane (15lb Felt) Plywood 5/8" I Joist 12" Deep @ 24" OC Insulation Nominal
More informationTIMBER REFLECTIVE NOISE BARRIER - ACOUSTIC FENCING. Acoustic Barriers. Gramm Barrier Systems Registered in England and Wales No:
TIMBER REFLECTIVE NOISE BARRIER - ACOUSTIC FENCING Acoustic Barriers Gramm Barrier Systems Registered in England and Wales No: 05836133 We have put a lot of thought into our noise barrier range and have
More informationEdition October May (always refer to the latest manual as set out on
LOXO PANEL INTER AND BLOCK TENANCY SYSTEMS WALLS TECHNICAL FIRE AND ACOUSTIC MANUAL REPORT PRODUCT DESCRIPTION AND BUILDING SYSTEM DETAILS Edition October May 2015 2014 (always refer to the latest manual
More informationDelia Chamberlain, Vice President, Kolay Floors Steve Hedback and Joel Esselstrom, SSA Acoustic, LLP
SSA Acoustics LLP 222 Etruria St, Suite 100 Seattle, WA 98109 Office: (206) 839-0819 TO: FROM: DATE: May 24, 2017 Delia Chamberlain, Vice President, Kolay Floors Steve Hedback and Joel Esselstrom, SSA
More informationConducting A Sound Insulation Test
Conducting A Sound Insulation Test . Why Test? Dwelling-houses, flats and rooms for residential purposes shall be designed and constructed in a such a way that they provide reasonable resistance to sound
More informationRC CHANNEL ACOUSTIC ASSEMBLY
RC CHANNEL ACOUSTIC ASSEMBLY FLOOR/CEILING ASSEMBLY DIRECT FIX TO TJI DSA TJI rc channel FSTC 53 FIIC 44 PAC INTERNATIONAL CONSTRUCTION * Hardwood Flooring * 1/2" Plywood Fire resistance ratings * 1-1/2"
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: AcoustiMac, LLC Tampa, FL. Sound Transmission Loss CONDUCTED: 2015-09-14 Page 1 of 8 ON: Sound Lock (Window+Door Sound Proofing Panel) Fabric Wrapped Panel - Wood Backing - Wood Frame TEST METHOD
More informationRIVERBANK ACOUSTICAL LABORATORIES
FOR: Bethany, CT. Sound Transmission Loss CONDUCTED: 2015-09-11 Page 1 of 7 ON: 5/16 inch Porcelain Tile - Fracture Ban 40 Peel and Stick Membrane - 6 inch Concrete Slabs TEST METHOD Riverbank Acoustical
More informationHudson Series 200 Acoustic Louvre
Louvreclad s Hudson Series is an acoustic louvre. It is the ideal solution when aesthetics are as important as noise reduction, ventilation, and weather protection. Distinctive Features + Diverse Applications
More informationH R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to AMORIM CORK COMPOSITES
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to AMORIM CORK COMPOSITES Series/Model: AcoustiCORK ECOx2 Sound Reduction Underlayment for LVT Plank Flooring Specimen Type: 152 mm
More informationHudson Series 300 Acoustic Louvre
Louvreclad s Hudson Series is an acoustic louvre. It is the ideal solution when aesthetics are as important as noise reduction, ventilation, and weather protection. Distinctive Features + Diverse Applications
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 3.1 IN SITU METHODS FOR THE CHARACTERISATION OF ROAD
More informationAcoustic design of industrial spaces. The reduction of noise levels and increase of production
Acoustic design of industrial spaces The reduction of noise levels and increase of production Contents. Introduction. Acoustic measurements Effect of acoustical treatment with suspended ceiling and wall
More informationCASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS
Abstract CASE STUDY OF THE SOUND REDUCTION OF VARIOUS RESIDENTIAL GLAZING TREATMENTS Greg Barry 1, Darren Jurevicius 2 and Matthew Stead 3 1 Resonate Acoustics, Adelaide SA 5082, Australia Email: greg.barry@resonateacoustics.com
More informationAcoustic properties of green walls: Absorption and insulation
PROCEEDINGS of the 22 nd International Congress on Acoustics Sustainable Materials for Sound Absorption and Insulation: Paper ICA2016-695 Acoustic properties of green walls: Absorption and insulation Rodolfo
More informationThe effect of additional thermal lining on the acoustic performance of a wall
The effect of additional thermal lining on the acoustic performance of a wall J. Nurzynski Building Research Institute, Filtrowa Str. 1, 00-611 Warsaw, Poland j.nurzynski@itb.pl 5417 External thermal insulation
More informationEffective Noise Barrier Design and Specification
Effective Noise Barrier Design and Specification Giles Parker Managing Director, Sound Barrier Solutions Ltd, Market Harborough, United Kingdom Chair CEN TC226/WG6/TG1 for Road Traffic Noise reducing Devices
More informationAcoustics in wooden buildings Measurements in the Laboratory and in Single Family Houses
Acoustics in wooden buildings Measurements in the Laboratory and in Single Family Houses Moritz Späh Andreas Liebl Philip Leistner SP Report 2014:14 SP Technical Research Institute of Sweden Box 857, 501
More informationAcoustical characterization of the underground chapels of the new Holy Trinity church in the Fatima shrine, Portugal
Acoustical characterization of the underground chapels of the new Holy Trinity church in the Fatima shrine, Portugal António P. O. Carvalho Lab. of Acoustics, Faculty of Engineering, University of Porto,
More informationProceedings of Meetings on Acoustics
Proceedings of Meetings on Acoustics Volume 2, 213 http://acousticalsociety.org/ 166th Meeting of the Acoustical Society of America San Francisco, California 2-6 December 213 Session 3aEDa: Education in
More informationAcoustic Louvres. Product and Technical Data
Acoustic Louvres Product and Technical Data INDUSTRIAL & ENVIRONMENTAL NOISE CONTROL SOLUTIONS WORLDWIDE PRODUCT DESCRIPTION Wakefield Acoustics specialises in the design and fabrication of a wide range
More informationSWEDISH STANDARD SS
SWEDISH STANDARD SS 02 52 68 Approved 2001-06-21 Edition 1 Acoustics Sound classification of spaces in buildings Institutional premises, rooms for education, preschools and leisure-time centres, rooms
More informationVALIDATION REPORT No
Istituto Giordano S.p.A. Via Rossini, - 4784 Bellaria-Igea Marina (RN) - Italia Tel. +39 054 343030 - Fax +39 054 345540 istitutogiordano@giordano.it - www.giordano.it PEC: ist-giordano@legalmail.it Cod.
More informationEnhancing Acoustic Performance through the use of Window Shade Fabric White Paper
Enhancing Acoustic Performance through the use of Window Shade Fabric White Paper As architecture and design evolve, more demand can be seen for obtaining creative solutions for occupancy comfort. In designing
More informationSolutions for industrial pipe work insulation
Solutions for industrial pipe work insulation Technical Insulation November 2006 Prefabricated insulation components for superior pipe work insulation Pipes are a crucial component in industrial processes.
More informationCJ Buma. To: Steelform Building Products Inc. Wednesday, 2007 May Avenue Edmonton, AB, T6B 2V2. Attn: Mr.
To: Steelform Building Products Inc. Wednesday, 2007 May 7 4104 69 Avenue Edmonton, AB, T6B 2V2 Attn: Mr. Marty MacDonald aci Acoustical Consultants Inc. Suite 107, 9920-63Ave Edmonton, Alberta, Canada
More informationFjardaal Smelter Project
Fjardaal sf Fjardaal Smelter Project Noise Survey 6 September 6 Fjardaal sf Fjardaal Smelter Project Noise Survey 6 September 6 Report no P-24-A-1 Issue no Date of issue 27 September 6 Prepared Checked
More informationIMPACT NOISE TESTING TIMBER FLOORING & ACOUSTIC UNDERLAY TESTING SCHNEID FLOORING AUSTRALIA PTY LTD
IMPACT NOISE TESTING TIMBER FLOORING & ACOUSTIC UNDERLAY TESTING SCHNEID FLOORING AUSTRALIA PTY LTD Date: Monday, th May 5 File Reference: 76C55mfcSchneidingAustralia Koikas Acoustics Pty Ltd Commercial,
More informationKinetics Noise Control
Kinetics Noise Control Acoustical Curtain Systems www.kineticsnoise.com Acoustical Curtain Systems Kinetics Noise Control s acoustical curtain systems are custom engineered to your application for acoustic
More informationCGV/RGV. Sound attenuating transfer units
Sound attenuating transfer units Quick facts For transfer air through walls Meets requirements for acoustic attenuation in normal constructions Flow range < 80 l/s Circular or rectangular hole in wall
More informationStatutory Order on noise from wind turbines
The full text Statutory Order on noise from wind turbines Pursuant to section 7(1), no. 1 and 2, section 7a(1), section 92 and section 110(3) and (4) of the Danish Environmental Protection Act, cf. Consolidation
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.6 THE CALCULATION
More informationABSORPTION PANELS FOR THE BEST POSSIBLE ACOUSTICS
ABSORPTION PANELS FOR THE BEST POSSIBLE ACOUSTICS MANUFACTURED IN THE UK INTRODUCING In many modern environments the emphasis has been to move to more open plan areas. Whether it is a school, an office,
More informationAirborne sound insulation evaluation and flanking path prediction of coupled room
Journal of Physics: Conference Series PAPER OPEN ACCESS Airborne sound insulation evaluation and flanking path prediction of coupled room To cite this article: R. D. Tassia et al 2016 J. Phys.: Conf. Ser.
More informationRSIC-1 ACOUSTIC ASSEMBLY
RSIC-1 ACOUSTIC ASSEMBLY FLOOR/CEILING ASSEMBLY DIRECT FIX TO CONCRETE SLAB FCS3 DSWA FIIC 69 PAC INTERNATIONAL Inc. Toll Free 866-774-2100 Telephone 503-649-7700 CONSTRUCTION * Ceramic Tile * 1/4" James
More informationRMF Intercell. NBS Specification 2013 K41
RMF Intercell NBS Specification 2013 K41 InterfaceFLOR BV. K41 Specification 40mm, 60mm, 80mm, 90mm and 110mm K41 Raised access floors To be read with Preliminaries/ General conditions. TYPES OF RAISED
More informationCommunity and Environmental Noise Measurement
Community and Environmental Noise Measurement How it differs from Occupation Noise Sampling Lee Hager, COHC, 3M PSD 1 Today s Instructor Lee Hager Past lhager@mmm.com 517-290-1907 Chair AIHA Noise Committee
More informationslimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units
slimlite Double Glazed Units BS EN 1279 Certificate slimlite Double Glazed Units Timber Georgian Sash and Case with Super Slimlite Double Glazed Units with, 8mm or 10mm cavity will comply with Document
More informationAcoustics Rating of sound insulation in buildings and of building elements. Part 1: Airborne sound insulation
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 717-1 Third edition 2013-03-01 Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation Acoustique
More informationThis page was. intentionally. left blank
CONSTRUCTION Measurement of Airborne Sound Insulation of 8 Wall Assemblies Measurement of Airborne and Impact Sound Insulation of 29 Floor Assemblies Nordic Engineered Wood Report No. A1-006070.10 July
More informationFreeze-thaw cycling with de-icing salt immersion, EN PAGEL V1/160 (0-16 mm)
TEST REPORT No. VTT-S-02665-16 29.6.2016 Freeze-thaw cycling with de-icing salt immersion, EN 13687-1 PAGEL V1/160 (0-16 mm) Requested by: Alimex Oy TEST REPORT No. VTT-S-02665-16 1 (3) Requested by Alimex
More informationJ. A. FERREIRA, F. B. DINIZ, A. FERREIRA and P. H. T. ZANNIN
ARCHIVES OF ACOUSTICS 29, 1, 123 127 (2004) TECHNICAL NOTES EVALUATION OF ACOUSTICAL PARAMETERS OF A BRAZILIAN POPULAR HOUSING MODEL J. A. FERREIRA, F. B. DINIZ, A. FERREIRA and P. H. T. ZANNIN Laboratory
More informationAcoustics and Classrooms BARD MANUFACTURING COMPANY REGISTERED AIA PRESENTER VAUGHAN SMITH
Acoustics and Classrooms BARD MANUFACTURING COMPANY REGISTERED AIA PRESENTER VAUGHAN SMITH Acoustics and Classrooms SOURCES OF NOISE ACOUSTICAL TERMS AND DEFINITIONS ANSI STANDARD OCCUPIED AND UNOCCUPIED
More information