Ammonia ph Cond BOD COD. mg/l N ph Units us/cm mg/l mg/l mg/l mg/l
|
|
- Dinah Gordon
- 5 years ago
- Views:
Transcription
1 Groundwater Historical Data Tot TOC E.Coli TON Parameter Coliforms ph Cond Cl DO Fe K Na MPN/ MPN/ mg/l Units ml ml ph Units us/cm mg/l mg/l mg/l mg/l mg/l MW 7 Qtr Qtr < Qtr < Qtr < MW 8 Qtr < Qtr < < Qtr < Qtr < MW 9 Qtr < < Qtr < < Qtr < <2.5 4 Qtr < Interim Guide Value NAC.5 NAC 6.5 & NAC Surface Water Historical Data ph Cond BOD COD Total Suspended Cl DO Parameter Solids mg/ ph Units us/cm mg/l mg/l mg/l mg/l Units l SW Qtr < 24 <5 2 9 Killynaher Lake Qtr < 2 < Qtr <5 2 Qtr < 2 <5 9.2 S.I No. 294/ and Leachate Historical Data Parameter TON ph Cond BOD COD Cl Units ph Units us/cm mg/l mg/l mg/l MW 6 Qtr < <6 3 6 Qtr Qtr 25.7 < Qtr Interim Guide Values.5 NAC 6.5& 9.5 2
2 ELS LTD ACCREDITATION SCHEDULE SUMMARY SHEET Miscellaneous (P,G,W,S) Other VOC's EO (P,G,S,W) Other VOC's EO (P,G,S) /Ammonium 7- EW54 Bromomethane.5-35 µg/l 22 Dichloropropane.5-35 µg/l Chloride 2.6- mg/l EW54 Ethyl Ether/Diethyl Ether.5-35 µg/l Flouride. - 2 mg/l EW37 Dichloroethene.5-35 µg/l PAH EO29 (P,G,S) COD 8-5 mg/l EW94 Iodomethane/Mehyl Iodide.5-35 µg/l Range -.2 µg/l Nitrate.2-5 EW54 Carbon Disulphide.5-35 µg/l Acenaphthene Nitrite 3- EW54 Allyl Chloride.5-35 µg/l Benzo (a) Anthracene ph 4 ph Units EW53 Methylene Chloride/DCM µg/l Benzo (a) Pyrene Phosphate 9- mg/l P EW54 2-Propenenitrile/Acrylonitrile µg/l Benzo (b) Fluoranthene Alkalinity -mg/l EW53 Chlormethyl Cyanide.5-35 µg/l Benzo (ghi) Perylene TOC.-mg/l EW23 Hexachlorobutadiene.5-35 µg/l Benzo (k) Fluoranthene BOD -3mg/l EW Trans-,2 Dichloroethene.5-35 µg/l Chrysene Total Nitrogen - EW4 MtBE.5-35 µg/l Dibenzo (ah) Anthracene Total Phosphorous -4 mg/l P EW43 Dichloroethane.5-35 µg/l Fluoranthene Suspended Solids 5-mg/l EW3 Cis-2 Dichloroethene.5-35 µg/l Fluorene Dissolved Oxygen to mg/l EW43 Methyl Acrylate µg/l Indeno (23-cd) Pyrene Conductivity -6 us/cm EW54 Bromochloromethane.5-35 µg/l Phenanthrene Miscellaneous (P,G,S) Tetrahydrofuran µg/l Pyrene Bromate to 5ug/l BRO3 EW37 Trichloroethane.5-35 µg/l Acid Herbicides (P,G,S) Colour 2.5-5mg/l PtCCo EW54 -Chlorobutane.5-35 µg/l Range -.2 µg/l Sulphate -mg/l SO4 EW54 Carbon Tetrachloride.5-35 µg/l 2,4,5-T H Total Dissolved Solids 5-mg/l EW46 Dichloropropene.5-35 µg/l 2,4-D H Total Hardness 3-33mg/l CaCO3 EM99 2 Dichloropropane.5-35 µg/l 2,4-DB H Total Oxidised Nitrogen.38-5 EW5 Dibromomethane.5-35 µg/l Turbidity.-5 NTU EW36 Methyl Methacrylate.5-35 µg/l Organophosphorus Pesticides(P,G,S) TKN Calculation -49 mg/l EW 3 Dichloropropene, cis µg/l Range -.2 µg/l Metals EM3 (P,G,S) MIBK/4 Methyl 2 Pentanone µg/l Famphur OP Aluminium 5. 5 µg/l Toluene.5-35 µg/l Methyl Parathion OP Antimony. µg/l 3 Dichloropropene,trans µg/l Parathion OP Arsenic.2-2µg/l Ethyl Methacrylate µg/l Barium. - µg/l 2 Trichloroethane.5-35 µg/l Organochlorine Pesticides (P,G,S) Boron 2 2mg/l 3 Dichloropropane.5-35 µg/l Range -.2 µg/l Cadmium. µg/l 2 Hexanone µg/l Aldrin Calcium. mg/l 2 Dibromoethane.5-35 µg/l BHC Alpha isomer OC Chromium. - µg/l Chlorobenzene.5-35 µg/l BHC Beta isomer OC Cobalt. - µg/l 2 Tetrachloroethane µg/l BHC Delta isomer OC Copper 3-4µg/l Ethyl Benzene.5-35 µg/l Dieldrin OC Iron 2-5µg/l m & p Xylene.5-35 µg/l Endosulphan Alpha isomer OC Lead.3-3µg/l O Xylene.5-35 µg/l Endosulphan Beta isomer OC Magnesium.3 2mg/l Stryene µg/l Endosulphan Sulphate OC Manganese. - µg/l Isopropyl Benzene.5-35 µg/l Endrin OC Mercury 2-2µg/l Bromobenzene.5-35 µg/l Heptachlor Epoxide OC Molybdenum. - µg/l 22 Tetrachloroethane.5-35 µg/l Heptachlor OC Nickel.5-5µg/l 23 Trichloropropane µg/l Lindane OC Potassium.2 2mg/l Propyl Benzene.5-35 µg/l P,P' DDE OC Selenium.2-2µg/l 2-Chlorotoluene.5-35 µg/l P,P'-DDD OC Sodium.5 5mg/l 4 Chlorotoluene.5-35 µg/l P,P'-DDT OC Strontium. - µg/l 35 Trimenthylbenzene.5-35 µg/l Tin. - µg/l Tert Butyl Benzene.5-35 µg/l Vanadium. - µg/l 24 Trimethlbenzene.5-35 µg/l Zinc. - µg/l Sec Butyl Benzene.5-35 µg/l SI439 Potable Water VOCs & THM 3 Dichlorobenzene.5-35 µg/l EO (P,G,S,W) P Isopropyltoluene.5-35 µg/l Benzene.-35 µg/l 4 Dichlorobenzene.5-35 µg/l.2-dichloroethane.-35 µg/l 2 Dichlorobenzene.5-35 µg/l Tetrachloroethene.-35 µg/l N Butyl Benzene.5-35 µg/l Trichloroethene.-35 µg/l Hexachloroethane µg/l Chloroform.-5 µg/l 2 Dibromo 3Chloropropane µg/l Bromoform.-35 µg/l 24 Trichlorobenzene.5-35 µg/l Dibromochloromethane.-35 µg/l 23 Trichlorobenzene.5-35 µg/l Bromodichloromethane µg/l Notes.Sample Matrix:P=Potable Water (Drinking), G=Ground Water, S=Surface Water, W=Waste Water Edition 6 T QP Appendix B Rev M Page of
3 ON SITE SAMPLING FORM Facility Name: Belturbet Waste Licence No: W92- Report To: Sampling Date: 28.5 Quarter 3 (GW, SW, Leachate) All Personnel: Brian Mc Aveety Weather: Dry Other Remarks: GPS: Sample Ref Sample Elec ph Temp Time DO Level No Type Cond (us) ph units C MW7 GW MW8 GW MW9 GW SW Lake SW Visual Clear Clear Cloudy Clear COMMENTS: Site Reference: Belturbet Sample Ref Depth of Well Cvan County Council Groundwater Sampling ref. Permit No. W92- Date: 28.5 Personnel: Depth of water below Ground Level Depth of water column Diameter of well Volume of Radius of well Radius squared water in well Volume of water in well Volume of water to purge Time to purge (m) (m) B A-B=h (m) (m) (m 2 ) (m3) π r2h litres (litres x 3) (mins) (Shallow/Deep) A B C (C/2) = r r 2 (m 3 x ) MW MW MW
4 / SW Lake 2/9/25 Surface Waters (as N) EW54M BOD BOD EW. <. COD COD EW Dissolved Oxygen Dissolved Oxygen EW43 9 Suspended Solids Suspended Solids EW3 5 <5 Default Not Analyzed Deg C ph EW ph Units DegC EW uscm-@2 2/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page of
5 / GW7 3/9/25 Ground Waters (as N) EW54M- 7. AQ2-UP Nitrate (as N) EW54M Nitrite (as N) EW54M- 3 <3 TON (as N) EW54M Coliforms Total Coliforms MIC E. Coli MIC33 2 Dissolved Oxygen Dissolved Oxygen EW43 2 Metals-Dissolved Iron-Dissolved EM Potassium-Dissolved EM Sodium-Dissolved EM Default Not Analyzed ph EW DegC EW Total Organic Carbon (TOC) Total Organic Carbon (TOC) EW MPN/ml MPN/ml ug/l Deg C ph Units uscm-@2 3/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page of 4
6 /2 GW8 3/9/25 Ground Waters (as N) EW54M- 7 AQ2-UP Nitrate (as N) EW54M-.2 Nitrite (as N) EW54M- 3 TON (as N) EW54M Coliforms Total Coliforms MIC33 E. Coli MIC33 Dissolved Oxygen Dissolved Oxygen EW43 Metals-Dissolved Iron-Dissolved EM3 2 Potassium-Dissolved EM3.2 Sodium-Dissolved EM3.5 Default ph EW53 DegC EW53 Total Organic Carbon (TOC) Total Organic Carbon (TOC) EW < < Not Analyzed MPN/ml MPN/ml ug/l Deg C ph Units uscm-@2 3/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page 2 of 4
7 /3 GW9 3/9/25 Ground Waters (as N) EW54M- 7 AQ2-UP Nitrate (as N) EW54M-.2 Nitrite (as N) EW54M- 3 TON (as N) EW54M Coliforms Total Coliforms MIC33 E. Coli MIC33 Dissolved Oxygen Dissolved Oxygen EW43 Metals-Dissolved Iron-Dissolved EM3 2 Potassium-Dissolved EM3.2 Sodium-Dissolved EM3.5 Default ph EW53 DegC EW53 Total Organic Carbon (TOC) Total Organic Carbon (TOC) EW <.2 <3 < < Not Analyzed MPN/ml MPN/ml ug/l Deg C ph Units uscm-@2 3/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page 3 of 4
8 /4 Michael Reilly 3/9/25 Ground Waters (as N) EW54M- 7 AQ2-UP Nitrate (as N) EW54M-.2 Nitrite (as N) EW54M- 3 TON (as N) EW54M Coliforms Total Coliforms MIC33 E. Coli MIC33 Dissolved Oxygen Dissolved Oxygen EW43 Metals-Dissolved Iron-Dissolved EM3 2 Potassium-Dissolved EM3.2 Sodium-Dissolved EM3.5 Default ph EW53 DegC EW53 Total Organic Carbon (TOC) Total Organic Carbon (TOC) EW <.2 <3 < Not Analyzed MPN/ml MPN/ml ug/l Deg C ph Units uscm-@2 3/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page 4 of 4
9 / 27/8/25 27/8/25 MW6 4/9/25 Waste Water (as N) EW54M AQ2-UP Nitrate (as N) EW54M-.6 <.6 Nitrite (as N) EW54M- 65 <65 TON (as N) EW54M-.69 < BOD BOD EW <6 Analyst BOD Comment: Result was outside range for the dilutions used COD COD EW Default Not Analyzed Deg C ph EW ph Units DegC EW53 uscm-@2 4/9/25.This Report shall not be Reproduced except in full, without the 3.=Result which is outside specification highlighted as -A Page of
10 Co en t ns of co For py in rig sp ht ect ow ion ne pu r r rp eq os ui es re o d nl fo y. ra ny he ru ot se.
Date Issued: July 01, 2018 Expiration Date: June 30, 2019
State of Florida Department of Health, Bureau of Public Health Laboratories This is to certify that EMSL ANALYTICAL, INC - CINNAMINSON 200 ROUTE 130 NORTH CINNAMINSON, NJ 08077 has complied with Florida
More informationInorganic Analytes - Metals. Aluminum ND mg/l 0.2 EPA Secondary 0.1. Arsenic ND mg/l EPA Primary Barium ND mg/l 2 EPA Primary 0.
Inorganic Analytes - Metals Aluminum ND mg/l 0.2 EPA Secondary 0.1 Arsenic ND mg/l 0.010 EPA Primary 0.005 Barium ND mg/l 2 EPA Primary 0.30 Cadmium ND mg/l 0.005 EPA Primary 0.002 Calcium 10.3 mg/l --
More informationNELAC PT for Accreditation Fields of Proficiency Testing with PTRLs Solid and Chemical Materials Effective January 3, 2012
Trace Metals mg/kg mg/kg SOLIDS 1000 Aluminum 1000 to 25000 Study Mean 0.1082 753.6118 100 SOLIDS 1005 Antimony 80 to 300 Study Mean 0.4385 8.1700 8.0 SOLIDS 1010 Arsenic 40 to 400 Study Mean 0.0915 1.0653
More informationCLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at
For International purchase only: Synthetic drinking water matrices with low concentrations of analytes for testing water supply, drinking water, or ground water. Standards are designed to meet the requirements
More informationTexas Commission on Environmental Quality
These fields of accreditation supercede all previous fields. The urges customers to Matrix: Air & Emissions Method 40 CFR Part 50 Appendix B Total Suspended Particulate TX 3973 10000304 Method 40 CFR Part
More informationNELAC PT for Accreditation Fields of Proficiency Testing with PTRLs Solid and Chemical Materials Effective: July 24, 2017
Trace Metals mg/kg mg/kg SOLIDS 1000 Aluminum 2500 to 25000 Study Mean 0.1307 293.1966 250 SOLIDS 1005 Antimony 80 to 300 Study Mean 0.4385 8.1700 8.0 SOLIDS 1010 Arsenic 40 to 400 Study Mean ± 30% SOLIDS
More informationMUNICIPAL DRINKING WATER PRODUCED BY DORVAL DRINKING WATER TREATMENT PLANT 2016
CONCENTRATION MIN. AVE. MAX. Physical Properties ph (units) 6.5-8.5 6.5-8.5 7.10 7.25 7.50 Turbidity (N.T.U.) 1.0 5 / 1 2 0.16 0.27 0.54 Biological Characteristics ANNUAL AVERAGE Total coliforms (PRE-ABS
More informationSample Number: Type of Water: Collection Date and Time: Received Date and Time: Date Completed:
Informational Water Quality Report Watercheck w/po Client: Ordered By: Aqua Falls Bottled Water 7606 Dayton Road Fairborn, OH 45324-1904 ATTN: Bob Kennedy Sample Number: Location: Type of Water: Collection
More informationTable B1: Analytical Results for Nutrients in Surface Water
Table B1: Analytical Results for Nutrients in Surface Water Sample ID 1 2 Physical Tests Colour, True (Colour Units) 15 (4) units absolute, or 5 units above background (30-day average)
More informationParameter monitored Standard methodology used Detection limit
A. Water sampling and analysis ph Potentiometry 0.0 ph units No Temperature Electrometer probe (in-situ) 0.05 o C No Dissolved oxygen Electrometer probe (in-situ) % No Salinity Electrometer probe (in-situ)
More informationA. Water sampling and analysis
A. Water sampling and analysis Parameter monitored Standard methodology used Detection limit Is this company accredited for this test? 1 ph Potentiometer 0.01 ph units No Temperature Electrometer probe
More informationParticipating Schedule for 2018/19
Participating Schedule for /19 Water Chemical Analysis Sample Name Analytes Enrolment Date Sample Dispatch Period Quarter 1 of Sample 3A: Mineral Constituents in potable water ph, Electrical Conductivity,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PACE ANALYTICAL SERVICES, LLC MOBILE LAB SERVICES 1 2525 Advance Rd. Madison, WI 53718 Pat Letterer Phone: 608 221 8700 ENVIRONMENTAL Valid To: March 31, 2020
More informationCadmium B ug/l HRL Chromium B ug/l MCL 100
Appendix 4, Table A4-1 Inorganics/Metals Arsenic 7440-38-2 6010B ug/l 25 4.41 10 MCL 2 Barium 7440-39-3 6010B ug/l 10 1.04 2000 HRL Use Tier 2 5 (or hardnessspecific value if lower) Cadmium 7440-43-9 6010B
More informationSubmittal Guidelines for Imported Soil. Soil Review & Acceptance Process
The following guidelines are provided as a prescriptive step process to ensure the contractual and regulatory requirements for Baylands Soil Processing are met and the appropriate quality control documentation
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MICROBAC LABORATORIES, INC., KTL DIVISION 3323 Gilmore Industrial Blvd. Louisville, KY 40213 Megan Rothgerber Phone: 502 962 6400 CHEMICAL Valid To: December
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited MICROBAC LABORATORIES, INC., KTL Louisville, KY for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the
More informationAnatek Labs, Inc - Spokane Spokane, WA
Anatek Labs, Inc - Spokane Spokane, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical
More informationState Regulations (Part 360) Landfill setting Monitoring activities Results Potential Impacts
State Regulations (Part 360) Landfill setting Monitoring activities Results Potential Impacts Environmental monitoring is just one of many landfill activities regulated by the state, including Permit application
More informationEnclosed please find your Bang for the Buck Essential Indicators Water Test report.
Dear Drinking Water Specialists Customer, Enclosed please find your Bang for the Buck Essential Indicators Water Test report. We have prepared the report with the consumer in mind, taking special care
More informationLocation: The contaminant was not detected above the minimum detection level.
Informational Water Quality Report Watercheck Client: Ordered By: Crystal Quest 2130 NW Park Way Suite I Marietta, GA 30067 ATTN: Mike Sigari Sample Number: Location: Type of Water: Collection Date and
More informationIf you have any additional questions concerning your report, please us at
Dear Drinking Water Specialists Customer, Enclosed please find your DWS Well Water Test. We have prepared the report with the consumer in mind, taking special care to provide an informative, yet simple
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS NORTH AMERICA INC. ALASKA DIVISION 200 W Potter Dr. Anchorage, AK 99518 Mary McDonald Phone: (907)-550-3203 mary.mcdonald@sgs.com ENVIRONMENTAL Valid To:
More informationQualitycheck Proficiency Testing Schemes Independent external evaluation of the analytical competence of testing laboratories. Application Form
Qualitycheck Proficiency Testing Schemes Independent external evaluation of the analytical competence of testing laboratories - 2019 Customize your participation, and only pay for what you need! The laboratory
More informationSample Number: Type of Water: Collection Date and Time: Received Date and Time: Date Completed: Revised Report
Informational Water Quality Report Citycheck Standard Client: Ordered By: Pure Effect Filters.com PO Box 50052 Staten Island, NY 10305 ATTN: Igor Milevsky Sample Number: Location: Type of Water: Collection
More informationCALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing
LIFORNIA STATE EIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing Western Environmental Testing Laboratory 475 East Greg Street Sparks, 89431 Phone: (775) 355-0202 Expiration Date
More informationSTATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION. is hereby granted to
STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION is hereby granted to ARDL, INC. 400 AVIATION DRIVE, P.O. BOX 1566 MT. VERNON, IL 62864 NELAP
More informationEnvironmental Laboratory Services Ltd
Acorn Business Campus, Mahon Industrial Park, Blackrock, Cork Testing Laboratory Registration number: 111T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule
More information25 Pa. Code Chapter 252 Page 1 of 5. DW/NPW Acidity, as CaCO 8 3 * 585 mg/l. DW/NPW Non-Filterable Residue (TSS) 8 14 mg/l
Microbiology Misc. Analytes NPW Total Coliform, MF 2 CFU/100mL DW/NPW Acidity, as CaCO 8 3 * 585 mg/l NPW Fecal Coliform, MF 2 CFU/100mL NPW Color * 1.7 PC units NPW E.coli, MF 2 CFU/100mL DW/NPW Non-Filterable
More informationExact Scientific Services, Inc. Ferndale, WA
Ferndale, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical parameters listed on the accompanying
More informationOREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation
MATRIX Reference Code Analyte Code Description STAT Analysis Corporation 40 CFR Part 50 Appendix J Environmental Laboratory Program 3950 Particulates
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Pace Analytical Services, LLC. 150 N 9 th Street Billings, MT 59101 Emily Agola Phone: (616) 656-2257 Emily.Agola@pacelabs.com ENVIRONMENTAL Valid To: May 31,
More informationEnvironmental Laboratory Services Ltd
Acorn Business Campus, Mahon Industrial Park, Blackrock, Cork Testing Laboratory Registration number: 111T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 3788 Laboratory Name: AGAT Laboratories - Burnaby Parent Institution: AGAT Laboratories Ltd. Address: 120-8600 Glenlyon Parkway Burnaby BC V5J 0B6 Contact:
More informationTNI/NELAP PT for Accreditation Fields of Proficiency Testing with PTRLs Non-Potable Water (NPW) Effective Date: March 16, 2015
Microbiology CFU/100 ml CFU/100 ml NPW 0233 2500 Total Coliform, MF 8 20 to 2400 Log transform; ±3 SD 2 NPW 0235 2530 Fecal Coliform, MF 8 20 to 2400 Log transform; ±3 SD 2 NPW 2525 E.coli, MF 8 20 to
More informationNELAC PT for Accreditation Fields of Proficiency Testing with PTRLs Non-Potable Water (NPW) Effective July 1, 2013
Microbiology CFU/100 ml CFU/100 ml NPW 0233 2500 Total Coliform, MF 8 20 to 2400 Log transform; ±3 SD 2 NPW 0235 2530 Fecal Coliform, MF 8 20 to 2400 Log transform; ±3 SD 2 NPW 2525 E.coli, MF 8 20 to
More informationCity of Ottawa Drinking Water Quality Test Results SUMMARY TABLE
0 Quality Test Results SUMMARY TABLE Communal Well System * Guidelines for Canadian Quality (Health Canada) & Ontario Standards (Ministry of Environment) -- not tested for Health Canada Guideline only
More informationROCKCASTLE SPRINGS. Secondary Contaminants. Climax, KY Raw Water Analysis. Bromide ND mg/l Not detected mg/l mg/l 0.
Secondary Contaminants 7429-90-5 Aluminum.021 mg/l 0.05 to 0.2 Bromide ND mg/l.015 58-08-2 Caffeine Not detected mg/l.053 16887-00-6 Chloride 2.0 mg/l 250 Color
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline Chemistry EPA 1664A (SGT-HEM) n-hexane Extractable Material - Silica Gel Treated (HEM-SGT) 8/21/2015 Aluminum 8/21/2015 Arsenic 8/21/2015 Barium 8/21/2015 Beryllium
More informationDate Issued: July 01, 2017 Expiration Date: June 30, 2018
State of Florida Department of Health, Bureau of Public Health Laboratories This is to certify that MAXXAM ANALYTICS - MICHIGAN 22345 ROETHEL DRIVE NOVI, MI 48375 has complied with Florida Administrative
More informationDROGHEDA LANDFILL SITE COLLON ROAD, MELL, DROGHEDA
GROUNDWATER MONITORING INFORMATION QUARTERLY REPORT FOR PERIOD APRIL TO JUNE 216 BY LOUTH COUNTY COUNCIL TO ENVIRONMENTAL PROTECTION AGENCY FOR WASTE LICENCE REFERENCE: W33-1 DROGHEDA LANDFILL SITE COLLON
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ENVIRONMENTAL CONSERVATION LABORATORIES JACKSONVILLE 4810 Executive Park Court, Suite 111 Jacksonville, FL 32216 Lori S. Mangrum Phone: 904 296 3007 Email address:
More informationPart 1: Property Ownership, Property Information and Owner s Certifications
Part 1: Property Ownership, Property Information and Owner s Certifications Information about the owner who is submitting or authorizing the submission of the record of site condition Owner name Owner
More information(Calibration) (Reference Material Production) ISO/IEC 17025:2005 (Calibration)
Name of Accreditation Program Accreditation No. Date of Initial Accreditation JCSS Accreditation Program JCSS0016 2005-12-26 (Calibration) 2007-10-24 (Reference Material Production) Latest Date of Issue
More informationMemorandum. To: Date: April 18, 2007 Re: Draft Borrow Source Sampling and Analysis Plan Port of Portland Terminal 4 Early Action
Anchor Environmental, L.L.C. 6650 SW Redwood Lane, Suite 110 Portland, OR 97224 Phone 503.670.1108 Fax 503.670.1128 Memorandum To: Anne Summers and Marcel Hermans Port of Portland From: Ben Hung and John
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Environmental Conservation Laboratories -
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 1429 Laboratory Name: Saint John Laboratory Services Ltd. Parent Institution: Address: 1216 Sand Cove Rd. Saint John NB E2M 5V8 Contact: Dr. Apollos Ikejiani
More informationOntario Soil Standards (other than sediment) II (mg/kg) Potable Ground Water Non-Potable Ground Water. Industrial/ Commercial
T3 Table 3 Soil quality benchmarks I Substance Ontario Soil Standards (other than sediment) II (mg/kg) Potable Ground Water Non-Potable Ground Water Canadian Environmental Quality Criteria and Guidelines
More informationIBWA STANDARD OF QUALITY REPORT
ONE CULLIGAN PARKWAY NORTHBROOK, IL 60062-6209 TELEPHONE FACSIMILE 847/205-6000 847/205-6030 Customer name Customer Address Customer city, state DAMBRA - DBA CULLIGAN Page 1 of 13 Sample Date 10/29/2014
More informationMARE BROOK ASSESSMENT. Technical Advisory Meeting # 2 Town of Brunswick, Maine April 27, 2016
MARE BROOK ASSESSMENT Technical Advisory Meeting # 2 Town of Brunswick, Maine April 27, 2016 MEETING AGENDA 1. Welcome &Introductions 2. Project Update a) Status of Project Tasks b) Review Schedule 3.
More informationLIMITS, STATE MINIMUM LEVELS, AND PERMIT LIMITS COMPARISON NPDES PERMIT CA
SANTA SUSANA FIELD LABORATORY SURFACE WATER SAMPLING PROGRAM LABORATORY MDLs, REPORTING LIMITS, STATE MINIMUM LEVELS, AND PERMIT LIMITS COMPARISON NPDES PERMIT CA0001309 Order No. R4-2007-0055 Monthly
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More information2010 POST-CLOSURE LANDFILL MONITORING TOWN OF BRIGHTON
2010 POST-CLOSURE LANDFILL MONITORING TOWN OF BRIGHTON Submitted To: New York State Department of Environmental Conservation Region 5 Office Submitted By: Town of Brighton Prepared By: F. X. Browne, Inc.
More informationSUBJECT DATE PAGE Item No Mineral EPA 13B. EPA 13A Chlorinated Hydrocarbons EPA TO-14A EPA TO-15 EPA TO-17 EPA TO-14A EPA TO-15
Approved Methods: Air and Emissions 03/30/2018 1 of 19 Autonomous Detection Systems Biological Critical Agents 99 NYSDOH Approved Method 9900 Chemical Critical Agents 99 NYSDOH Approved Method 9900 Radioactive
More informationWATER QUALITY REPORT
P R I S T E G WATER QUALITY REPORT PROUD SOURCE WATER, PRISTINOCKY MOUNTAIN SPRING WATER, SOURCE MEETS ALL FEDERAL AND STATE HEALTH STANDARDS. BOTTLED WATER IS REGU- LATED BY THE FDA AND IS CLASSIFIED
More informationFREY ENVIRONMENTAL, INC.
FREY ENVIRONMENTAL, INC. Environmental Geologists, Engineers, Assessors 2817 A Lafayette Avenue Newport Beach, CA 92663 (949) 723-1645 Fax (949) 723-1854 Email: Freyinc@freyinc.com June 18, 2014 770-01
More informationWATER QUALITY REPORT INTRODUCTION
INTRODUCTION The Mountain Valley Spring, a natural protected spring source, meets all federal and state health standards. FDA regulates bottled water as a food product. The exacting standards of quality
More informationCITY OF FREMONT DEPARTMENT OF WATER POLLUTION CONTROL
CITY OF FREMONT DEPARTMENT OF WATER POLLUTION CONTROL APPLICATION FOR: ( ) 1. NEW WASTEWATER CONTRIBUTION PERMIT ( ) 2. RENEWAL OF WASTEWATER CONTRIBUTION PERMIT THE FOLLOWING FACILITY HEREBY MAKES THIS
More informationFrench Creek Well # 2 Water Analysis Behind 1221 Ormonde Road
French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road October 27 2010 Inorganics Fluoride 1.5 MAC 0.17 0.13
More informationIH Scan Packages Novi Laboratory
IH Scan Packages Novi Laboratory SCANS ACIDS, INORGANIC (5) OSHA ID-165SG / ID-174SG Hydrogen Bromide Sulfuric Acid Silica Gel Tube, washed SKC 226-10-03 or ORBO 53 Hydrogen Chloride Phosphoric Acid Nitric
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More information2015 Water Analysis Report for Purified Drinking Water
2015 Water Analysis Report for Purified Drinking Water Substance Units MDL* MCL** Market Pantry Purifi ed Water Physical Quality Alkalinity as CaCO3 mg/l CaCO3 5 NR ND Color Color unit 5 15 ND Hardness,
More informationDurban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014
Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July 2013-30 June 2014 Durban Heights WW Raw Durban Heights WW Final Determinands Units Minimum Average Percentile Maximum Minimum Average
More informationAmy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method 8260 in conjunction
More informationWater Analysis Report (2017)
Analysis Report (2017) Type Physical Quality Alkalinity as CaCO3 mg/l CaCO3 5 NR 0.52 9.69 Color Color unit 5 15 ND ND Specific Conductance umhos/cm 0.1 NR 3.95 45.79 Hardness, Total mg/l CaCO3 2 NR ND
More informationCertified Reference Materials for Water & Wastewater Analysis
Certified Reference Materials for Water & Wastewater Analysis Table of Contents Free and Total Chlorine... 4 Wastewater Demands.... 6 Solids in Wastewater.... 8 Universal Wastewater Standards....10 Oil/Grease,
More informationPasco County Florida. Water Monitoring Plan West Pasco Class I Landfill PA87-23, WACS # Revised April 2014
Pasco County Florida Water Monitoring Plan West Pasco Class I Landfill PA87-23, WACS # 45799 Revised April 2014 Table of Contents Section 1 Introduction... 1 Section 2 Groundwater Quality Monitoring Network...
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17043:2010
SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010 NEW YORK STATE DEPARTMENT OF HEALTH WADSWORTH CENTER Biggs Laboratory, Wadsworth Center NYS Department of Health, Empire State Plaza, D224 Albany, NY 12201-0509
More informationUS EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1803 P+T VOC ENV US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific TRACE 1310 GC and ISQ MS Amy Nutter, Applications Chemist; Teledyne Tekmar Page
More informationDrinking Water Quality and Compliance SaskWater Codette Lake Potable Water Supply System 2017 Notification to Consumers
Drinking Water Quality and Compliance SaskWater Codette Lake Potable Water Supply System 2017 Notification to Consumers The Water Security Agency (WSA) requires that, at least once each year, waterworks
More informationSOIL MANAGEMENT PLAN THE CITY OF KNOXVILLE
SOIL MANAGEMENT PLAN SOUTH WATERFRONT RIVER PLAIN PARK Prepared For: THE CITY OF KNOXVILLE Knoxville, TN Prepared By: MACTEC ENGINEERING AND CONSULTING, INC. January 11, 2010 MACTEC Project 3043-08-1018
More informationSTATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION. is hereby granted to
STATE OF ILLINOIS ENVIRONMENTAL PROTECTION AGENCY NELAP - RECOGNIZED ENVIRONMENTAL LABORATORY ACCREDITATION is hereby granted to SUBURBAN LABORATORIES, INC. 1950 SOUTH BATAVIA AVE., SUITE 150 GENEVA, IL
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:, Inc. 10100 East Freeway, Suite 100, Houston, TX 77029
More informationClinical Laboratory of San Bernardino, Inc. Celebrating 50 Years of Analytical Service
Project: Annual Title 22 Work Order: 18J2231 Received: 10/25/18 16:15 Reported: 11/26/18 AAC Drop 4 #A 18J2231-04 (Water) Sample Date: 10/25/18 11:00 Sampler: Bryan Blowney General Physical Analyses Apparent
More informationUS EPA Method Atomx XYZ and Agilent 7890B GC/5977A MS
Application Note Environmental US EPA Method 524.3 Atomx XYZ and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 524.3 was used to determine the
More informationAPPENDIX B. Soil Sample Certificate of Analysis
APPENDIX B Soil Sample Certificate of Analysis 5 SHOREHAM DR DOWNSVIEW, ON M3N1S4 SOIL ANALYSIS REVIEWED BY: Mike Muneswar, BSc (Chem), Senior Inorganic Analyst TRACE ORGANICS REVIEWED BY: Jacky Takeuchi,
More informationMs. Kathy Evans West Michigan Shoreline Regional Development Commission 316 Morris Avenue, Ste 340 Muskegon, Michigan 49440
July 19, 2018 Consulting Engineers and Scientists Ms. Kathy Evans West Michigan Shoreline Regional Development Commission 316 Morris Avenue, Ste 340 Muskegon, Michigan 49440 Sent via email to KEvans@wmsrdc.org
More informationPOST-REMOVAL GROUNDWATER SAMPLING REPORT
POST-REMOVAL GROUNDWATER SAMPLING REPORT Area of Concern (AOC) No. 2 Former Schenectady Army Depot - Voorheesville Area Guilderland, New York Contract No. DACA87-02-D-0005 Task Order No. 18 Submitted to:
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar Page 1
Application Note US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Abstract US EPA Method
More informationASBG s Comparison of Queensland vs NSW and Victoria s Hazardous Waste Classifications
ASBG s Comparison of Queensland vs NSW and Victoria s Hazardous Waste Classifications Note the Queensland limits set their levy rates of $35/t, $50/t and $150/t on wastes. Unlike NSW and Victorian limits
More informationProject Supported By. Grand Traverse Band of Ottawa and Chippewa Indians Leelanau Clean Water Glen Lake Association
BASELINE Project Supported By Grand Traverse Band of Ottawa and Chippewa Indians Leelanau Clean Water Glen Lake Association Project Director: Sarah Litch Glen Lake Association Water Quality Leelanau Clean
More informationUS EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS
Application Note US EPA Method 8260 With the Tekmar Lumin and the Agilent 7890B GC/5977A MS Author Roger Bardsley Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 is used primarily by
More informationTSB-1 TSB-3 TSB-2. Legend. Approximate Site Limits. Soil Boring Location. Feet. Figure 2 Boring Location Map
TSB-1 TSB-3 TSB-2 Legend 0 150 300 450 600 Feet East of Calhoun Road & South of Griggs Road Houston, Harris County, Texas TGE Project No.: R10114.01 6120 West by Northwest Blvd. Suite 100 Houston, Texas
More informationP02-04 CALA Program Description - PT Catalogue Revision 1.19 October,
Revision 1.19 October, 20 2017 TABLE OF CONTENTS 1.0 INTRODUCTION... 2 2.0 REFERENCES... 2 3.0 2018 SHIPPING SCHEDULE... 3 4.0 REGISTRATION... 3 5.0 TESTS OFFERED IN THE CALA PT PROGRAM... 4 5.1 INORGANICS
More informationRoger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 524.3 with the Tekmar Lumin P & T Concentrator and Agilent 7890B GC and 5977A MSD System Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method
More informationBOTTLED WATER QUALITY REPORT. PLEASS GLOBAL LIMITED 16 Amra Street Walu Bay Suva, Fiji (+679) TOTAL DISSOLVED SOLIDS ph 7.
BOTTLED WATER QUALITY REPORT PLEASS GLOBAL LIMITED 16 Amra Street Walu Bay Suva, Fiji (+679)3308803 INTRODUCTION AquaSafe natural artesian water, meets all the FDA and ABWI standards.fda regulates bottled
More informationRe: Amendment to Certificate of Property Use No JWJJC (CPU) West Don Lands Group 1, Toronto (Property) for Property Specific Standards (PSS)
Ministry of the Environment and Climate Change Central Region Office 5775 Yonge Street 8 th Floor North York ON M2M 4J1 Tel.: 416 326-6700 Fax: 416-325-6346 Ministère de l Environnement et de l Action
More informationProject Supported By. Grand Traverse Band of Ottawa and Chippewa Indians Leelanau Clean Water Glen Lake Association
1 BASELINE Project Supported By Grand Traverse Band of Ottawa and Chippewa Indians Leelanau Clean Water Glen Lake Association Project Director: Sarah Litch Glen Lake Association Water Quality Leelanau
More informationPotable Water. Requirement
Purpose To ensure the consistent quality and safety of potable water used in the Coca-Cola system manufacturing facilities for potable water applications. Scope This document applies to the Coca-Cola system
More informationSARATOGA SPRING WATER COMPANY 11 Geyser Road, Saratoga Springs, New York Phone: , Fax: , Web:
Bottler s Name: Saratoga Spring Water Company BOTTLED WATER REPORT Address: 11 Geyser Road, Saratoga Springs, NY, 12866 Telephone Number: 518-584-6363 Source(s): Spring Water Sweet Water Spring Saratoga
More informationOREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation Advanced Technology Laboratories
MATRIX Reference Code Analyte Code Description Air ASTM D1946-90 OREGON Environmental Laboratory Program 4747 Ethane 4752 Ethene 4926 Methane 30024465 Reformed Gas by Gas Chromatography EPA TO-14A 10248609
More informationThis is a courtesy copy of this rule. All of the Department s rules are compiled in Title 7 of the New Jersey Administrative Code.
Subchapter 12. Effluent Standards Applicable to Direct Discharges to Surface Water and Indirect Discharges to Domestic Treatment Works 7:14A-12.1 Purpose and Scope (a) This subchapter specifies Federal
More informationWASHINGTON STATE DEPARTMENT OF ECOLOGY
WASHINGTON STATE DEPARTMENT OF ECOLOGY ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM SCOPE OF ACCREDITATION AmTest Laboratories Kirkland, WA is accredited for the analytes listed below using the methods
More informationThe licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.
Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where non-compliance against a particular condition has not
More informationWASTE CHARACTERIZATION: IN-SITU SOIL LOCATED AT ISRA AREA II PLANNED EXCAVATION ELV-1D POND DEEP SOIL
WASTE CHARACTERIZATION: IN-SITU SOIL LOCATED AT ISRA AREA II PLANNED EXCAVATION ELV-1D POND DEEP SOIL Introduction Supporting detailed information is provided in this report for the June 27, 2013 in-situ
More informationPOST CLOSURE ENVIRONMENTAL MONITORING REPORT (May 2016 Data)
POST CLOSURE ENVIRONMENTAL MONITORING REPORT (May 2016 Data) Shawmut Avenue Landfill New Bedford, Massachusetts MassDEP DSWM Transmittal No. ACOP SE 08 4004 SEP 120068 Prepared For: Massachusetts Department
More informationAppendix I. Agreement on National Environmental Standards of Lao PDR, 2009
Appendix I Agreement on National Environmental Standards of Lao PDR, 2009 I.1 DRINKING WATER QUALITY STANDARDS Lao PDR current standards for drinking water of the Lao PDR are provided below for reference.
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 3588 Laboratory Name: AGAT Laboratories (Dartmouth) Parent Institution: AGAT Laboratories Ltd. Address: 11 Morris Drive Unit 122 Dartmouth NS B3B 1M2 Contact:
More informationSPECTRUM ANALYTICAL, INC. Featuring HANIBAL TECHNOLOGY. Laboratory Report. Project: PWTF North Road, NY
Report Date: 4-Jul-09 5:3 ü Final Report Re-Issued Report Revised Report Poughkeepsie Water Treatment Facility 343 North Road Poughkeepsie, NY 260 Attn: Matthew Geho SPECTRUM ANALYTICAL, INC. Featuring
More informationThank you for your request for a scope revision. Enclosed is your revised WA Scope of Accreditation, effective July 25, 2018.
July 9, 2018 Mr. Matt Sowards ACZ Laboratories, Inc. 2773 Downhill Drive Steamboat Springs, CO 80487 Dear Mr. Sowards: Thank you for your request for a scope revision. Enclosed is your revised WA Scope
More information