50 Hz. ecocirc PRO Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS DE: +41 (0) FR: +41 (0) Rev. Cod.

Size: px
Start display at page:

Download "50 Hz. ecocirc PRO Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS DE: +41 (0) FR: +41 (0) Rev. Cod."

Transcription

1 Hz ecocirc PRO Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS Cod. 9 Re e.a.a Ed.9/ DE: + () FR: + () 9

2 ecocirc PRO SERIES INSTALLA ALLATION POSITIONS Lowara is a trademark of Lowara srl Unipersonale, subsidiary of Xylem Inc. ecocirc is a trademark of Laing Thermotec Inc, subsidiary of Xylem Inc. Xylect is a trademark of Xylem Water Solutions AB, subsidiary of Xylem Inc.

3 High efficiency electronic sanitary circulators MARKET SECTORS RESIDENTIAL. APPLICATIONS Hot water circulation. ecocirc PRO SERIES SPECIFICATIONS PUMP Flow rate: up to m /h. Head: up to m. Temperature of pumped liquid: + C + C. Aoid condensation and ice formation. Maximum operating pressure: bar (PN ). Rotor assembly group: made of stainless steel/composite material/carbon. MOTOR Permanent magnet EC (Electronically Commutated) type motor with spherical rotor/stator. Wet rotor with a single spherical ceramic/carbon ball bearing. Integrated motor protection; no external protection required. Single-phase -V / Hz power supply. Motor type: - Fixed speed for temperature sensor and temperature sensor + timer models; - Variable speed with automatic regulation for basic and timer models. Insulation class F ( C). Protection class: IP no-timer models. IP timer models.

4 ecocirc PRO SERIES CONSTRUCTION CHARACTERISTICS Electric circulator pumps for domestic hot water applications at maximun temperature of C, at maximum hardness of f ( dh). Brassy pump body for direct installation onto piping for /" and /" - " /" teaded union connections. The design is based on spherical rotor/stator technology. This means that: - The only moing part is the spherical rotor/impeller unit that turns on a hard ceramic ball. - Shaft seals or conentional bearing bushings with a shaft hae been eliminated for a single self realigning spherical bearing. Blockage free rotor: the spherical motor principle does not require a manual unblocking deice thanks to the small touching surface of the bearing on the ball. The starting torque required is minimal. Air-purge functionality: an automatic and quick routine to remoe the air from the circulator and ensure safe operation. Stand-by mode. Self diagnostic and malfunction detection: defects detected by the pump system are signalled with alternating LED light flashes. Insulation shell as a standard. Models aailable: - Fixed speed Temperature sensor to maintain the water onto piping at the required temperature. The circulator automatically turns off when the water temperature achiees the alue. Temperature can be set up between C and C by the selector on the motor. Temperature sensor and timer for more energy saing. - Variable speed: Performances optimized by system requests. Speed set up is done by a selector on the motor by different positions. At and positions (ECO) the consumption is especially low. Timer as a standard in order to daily set up the performances. mm port-to-port length models are fitted out with non-return and shut off ale. mm port-to-port length models are fitted out with a non-return ale to install to supply connection. According to EN standards -, --, -, -. ACCESSORIES SORIES Pipe unions. INSTALLA ALLATION Suitable for installation in ertical or horizontal piping, in this last case not with the motor housing upward.

5 ecocirc PRO SERIES IDENTIFICATION TION CODE ecocirc PRO / R U NULL = NO TIMER U = WITH TIMER NULL = NO TEMPERATURE SENSOR R = WITH TEMPERATURE SENSOR PORT TO PORT DISTANCE IN mm. MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER SERIES NAME EXAMPLE : ecocirc PRO -/ RU Electronic circulator of the ecocirc PRO series, port nominal diameter =, max head = m, port to port distance mm, with temperature probe and timer. TABLE OF MATERIALS PART MATERIAL Pump body Rotor assembly group Bearing Gaskets Brass Stainless steel Composite material Carbon Ceramic EPDM eb--en_b_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) The benchmark for most efficient circulators is EEI, : note not applicable to these products. c) Information releant for disassembly, recycling or disposal at end-of-life: obsere the current laws and by-laws goerning sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: This circulator is suitable for drinking water only.

6 ecocirc PRO SERIES HYDRAULIC PERFORMANCE TABLE PUMP POWER SPEED Q = DELIVERY TYPE ABSORBED l/s,,,,,,9,,,,9 ecocirc PRO MIN MAX m /h,,,,,,,,, V Hz W W H = TOTAL HEAD METRES COLUMN OF WATER -/ R,9, max,,,,9,,,, -/ RU, 9, max,,,,9,,,, -/ R,, max,,9,,9,,9 -/ RU,, max,,9,,9,,9 -/ -/ U -/ -/ U -/ -/,,,,,,,,,,,, min min min min min min,,,,,,,,,,,,,,,,,9,,,,,, 9,,,,, max max max max max max,,,,,,,,,9,9,9,,,,,,,,9,9,9,9,,9,,,,,,,,,9,9,,,,,,,,,,,9,9,9,9 Hydraulic performances in compliance with ISO 99: - Grade B (ex ISO 99:999 - Annex A) ecocirc-pro--en_e_th

7 ecocirc PRO SERIES SINGLE-PHASE OPERATING CHARACTERISTICS ecocirc PRO -/ R ISO 99: - Grade B ecocirc PRO -/ RU ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] Q [US gpm], H [m] H [ft] H [kpa] Q [US gpm], H [m] H [ft] H [kpa],,,,,,,,,,,, P [W] P [W],,,,, Q [m /h],,,,,,, Q [l/s] 9E_D_CH,,,,, Q [m /h],,,,,,, Q [l/s] E_C_CH ecocirc PRO -/ R ISO 99: - Grade B ecocirc PRO -/ RU ISO 99: - Grade B,,,, Q,[Imp gpm],,,, Q,[Imp gpm],,,,, Q [US, gpm], H [m] H [ft] H [kpa],,,,, Q [US, gpm], H [m] H [ft] H [kpa],,,,,,,,,,,, P [W] P [W],,,,,, Q [m /h],,,,, Q [l/s] 9E_D_CH,,,,,, Q [m /h],,,,, Q [l/s] E_C_CH These performances are alid for liquids with density ρ =. Kg/dm and kinematic iscosity ν = mm /sec.

8 ecocirc PRO SERIES SINGLE-PHASE OPERATING CHARACTERISTICS * ecocirc PRO -/ ISO 99: - Grade B * ecocirc PRO -/ ISO 99: - Grade B Q [Imp gpm],,,, Q,[Imp gpm] Q [US gpm], H [m] H [ft] H [kpa],,,,, Q [US, gpm], H [m] H [ft] H [kpa],,,,,,,,,,,, P [W] P [W],,,,, Q [m /h],,,,,,, Q [l/s] E_C_CH,,,,,, Q [m /h],,,,, Q [l/s] E_C_CH * ecocirc PRO -/ U ISO 99: - Grade B * ecocirc PRO -/ U ISO 99: - Grade B Q [Imp gpm],,,, Q,[Imp gpm] Q [US gpm], H [m] H [ft] H [kpa],,,,, Q [US, gpm], H [m] H [ft] H [kpa],,,,,,,,,,,, P [W] P [W],,,,, Q [m /h],,,,,,, Q [l/s] E_C_CH,,,,,, Q [m /h],,,,, Q [l/s] E_C_CH These performances are alid for liquids with density ρ =. Kg/dm and kinematic iscosity ν = mm /sec. * Pump operates steplessly. Lines correspond to knob settings and are for reference only.

9 ecocirc PRO SERIES SINGLE-PHASE OPERATING CHARACTERISTICS * ecocirc PRO -/ ISO 99: - Grade B * ecocirc PRO -/ ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] H [m],, Q [US gpm] H [ft] H [kpa] Q [US gpm], H [m] H [ft], H [kpa],,,,,,,,, P [W],,,,,,,, Q [m /h],,,,,, Q [l/s] 9E_C_CH,,, P [W],,,,,, Q [m /h],,,,, Q [l/s] E_B_CH These performances are alid for liquids with density ρ =. Kg/dm and kinematic iscosity ν = mm /sec. * Pump operates steplessly. Lines correspond to knob settings and are for reference only. 9

10 ecocirc PRO SERIES DIMENSIONS AND WEIGHTS DIMENSIONS AND WEIGHTS TABLE PUMP TYPE ecocirc PRO DIMENSIONS (mm) A A B B C C DN kg -/R -/ - - -,9 -/RU -/U /R -/ - - -, -/RU -/U - - -, -/ - - -,9 -/ - - -, PESO ecocirc-pro-p-en_d_td

11 TECHNICAL APPENDIX

12 VAPOUR PRESSURE SURE VAPOUR PRESSURE SURE ps AND ρ DENSITY OF WATER TABLE t T ps ρ t T ps ρ t T ps ρ C K bar kg/dm C K bar kg/dm C K bar kg/dm,,,999,,,9 9,,9,99,,,9999 9,,,9 9,,,9,,,9999,,,9 9,,,99,,,9999,,,9 99,,9,99,,, 9,,9,9,,,9,,,,,99,9,,,9 9,,9,,,,9,,,9,,,9999,,,9,,,9,,,9999,,,9 9,,,99 9,,,999,,9,9,,,9,,,999,,,9,,,9,,,999 9,,,999,,,9,,,999,,,99,,,9,,9,999,,,9,,,9,,9,999 9,,9,9,,,9,,,999,,,9,,9,9 9,,,999,,,9,,9,9 9,,9,99,,9,9,,,9 9,,,99,,,9,,, 9 9,,9,99,,9,9 9,,, 9,,,99,,,9 9,,9, 9,,,99 9,,9,9,,, 9,,,99,,9,9,,, 9,,,99,,,99, 9,, 9,,9,99 9,,,9,,, 9,,,99,,,9 9,,9, 99,,,99,,9,9 9,,,9,,,99,,,9,,9,,,,99,,,99,,, 9,,,99,,,99,,,,,,99,,,9,,,,,9,99 9,,,9, 9,,99,,,99,,9,9,,,9,,9,99,,9,9,,9,9,,,99 9,,9,9,,,9,,,99 9,,,9,,, 9,,9,99 9,,,9, 9,9,9,,,99 9,,,9,,,,,,99 9,,9,9, 9,, 9,,99,99 9,,,9 9,,,,,,99 9,,,9 9,,,,,, ,,9,9,,9,,,9,99 9,,99,9, 9,,,,99,99 9,,9,99, 9,,9,,9,99 99,,9,9,,,9,,9,99,,,9 9,,9,9 9,,,99,,,9 9,,,,,,99,,,9,,,,,,99 9,,,9,,, 9,,,9,,9,9,,,,,,9,,,9,,,,,9,9,,,99,,,,,,9,,,9,,,,,,9,9 9,,,9,,,9 9,,,9 G-at_npsh_b_sc TECHNICAL APPENDIX

13 TABLE OF FLOW RESISTANCE IN m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=) FLOW RATE NOMINAL DIAMETER in mm and inches m /h l/min /" /" " /" /" /" " " " " " " " " " ",,9,,,,,,,,,, 9, ,9,,9,,,,,,,,,,,,,,,,9,,,,9,9,,,,,9,,9,,,9,9,,,,9,9,,,,,9,,,,,,,,,9,99,,,,,,,,,,,,,9,,,,,,,,,,,,,,,,,,9,,,,,,9,,,,9,,,,,,99,,,99,,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,9,,9,,,,,9,,,,,,,,,,,,,,,,,,,,9,,,,,,,,,,,,,9,9,,9,,,,9,,9,,,,,,9,,, for galanized or painted steel pipes,,,,,,,,,,,,,,,,,,,,,,,,9,,,,,,,9,,,,,9,,, for PVC or PE pipes,,,,,9,,,,,,9,,,,,9,9,9,,,,, 9, 9,9 9,,,, 9, 9, 9, 9,,, 9,,,,,9,,,,,,,,,,,,,,,9,,,,,,,,,,,9,9,,,,,,, 9,,,9 9,,9,,,9,,,,9,,,,, 9,,, 9,,,,,,,9,9, 9,,9,,,9 9,,,,,,, 9,,9,,,,,,,,,,,,9,,,,,9,,,9,9,,,,,,,,9,,,9,9,9,,,,,9,,,,,9,9,,,,9,9,,,,,9,,9,9,,,,,,,,,,,,9,,,,,,,,,,,, The alues must be multiplied by:, for stainless steel or copper pipes,,,,,,,,,9,,,9,,,,,,,,,,,9,,,,,9,,9,9,,,,,,,,,,,,,,,,,,,,9,,,, = flow resistance for m of straight pipeline (m) V = water speed (m/s) G-at-pct-en_a_th TECHNICAL APPENDIX

14 FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VAL ALVES AND GATES The flow resistance is calculated using the equialent pipeline length method according to the table below: ACCESSORY TYPE Equialent pipeline length (m) bend,,,,,,,9,,,9,, 9 bend,,,9,,,,,,,9,, 9 smooth bend,,,,,9,,,,9,,,9 Union tee or cross,,,,,,,,,,,, Gate - - -,,,,,,,9,, Non return ale,,,9,,,,,9, 9,,,9 DN G-a-pc-en_a_th The table is alid for the Hazen Williams coefficient C= (cast iron pipework); for steel pipework, multiply the alues by,; for stainless steel, copper and coated cast iron pipework, multiply the alues by,; When the equialent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance. The alues gien are guideline alues which are bound to ary slightly according to the model, especially for gate ales and non-return ales, for which it is a good idea to check the alues supplied by manufacturers. TECHNICAL APPENDIX

15 VOLUMETRIC CAPACITY ACITY Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal. per minute per hour per hour per minute per minute per minute l/min m /h ft /h ft /min Imp. gal/min Us gal./min,,,9,,,,,,,,,9,9,,,,,,,99,,,,,, 9,,,,9,,,,,, PRESSURE SURE AND AND HEAD HEAD Newton per kilo Pascal bar Pound force per metre millimetre of square metre square inch of water mercury N/m kpa bar psi m H O mm Hg,, x -. x -. x -,,,,,,, x,,,,9, 9,,9,9,,, 9, 9,,9,,,,,,,9,, LENGTH millimetre centimetre metre inch foot yard VOLUME mm cm m in ft yd,,,,9,,,,,,9,,9,,, 9,,,9,,,,,,,,,,,, 9, 9,,9,,, cubic metre litre millilitre imp. Gallon US gallon cubic foot m litro ml imp. gal. US gal. ft,, x 9,99,,,,,,,, x -,,. x -. x -. x -,,,,,9,,,,,,,,,,,,, G-at_pp-en_a_sc TECHNICAL APPENDIX

16 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM Xylect TM is pump solution selection software with an extensie online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output gien makes it easy to make the optimal selection without haing detailed knowledge about the Lowara and Vogel products. The search can be made by: Application Product type Duty point Xylect TM gies a detailed output: List with search results Performance cures (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. TECHNICAL APPENDIX

17 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM The detailed output makes it easy to select the optimal pump from the gien alternaties. The best way to work with Xylect TM is to create a personal account. This makes it possible to: Set own standard units Create and sae projects Share projects with other Xylect TM users Eery user hae a My Xylect space, where all projects are saed. For more information about Xylect TM please contact our sales network or isit Dimensional drawings appear on the screen and can be downloaded in dxf format. TECHNICAL APPENDIX

18

19

20 Xylem zīl m e ) The tissue in plants that brings water upward from the roots; ) a leading global water technology company. We re approximately, people unified in a common purpose: creating innoatie solutions to meet our world s water needs. Deeloping new technologies that will improe the way water is used, consered, and reused in the future is central to our work. We moe, treat, analyze, and return water to the enironment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than countries, we hae strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innoation. For more information on how Xylem can help you, go to xyleminc.com. Hauptsitz Gloor Pumpenbau AG Thunstrasse CH- Rubigen Tel. + () Fax + () office@gloor-pumpen.ch Bureau Suisse Romande Gloor Pumpenbau SA Rue du Collège Case postale CH- Thierrens Tél. + () 9 office@gloor-pumpen.ch Xylem Water Solutions Italia Srl reseres the right to make modification without prior notice. Lowara, Xylem are trademarks of Xylem Inc. or one of its subsidiaries Xylem, Inc.

50/60 Hz. ecocirc PREMIUM Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

50/60 Hz. ecocirc PREMIUM Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC / Hz ecocirc PREMIUM Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev.A Ed./ ecocirc PREMIUM SERIES INSTALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

60 Hz. VM Series CLOSE-COUPLED THREADED VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS COMPLYING WITH IEC

60 Hz. VM Series CLOSE-COUPLED THREADED VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS COMPLYING WITH IEC 60 Hz VM Series CLOSE-COUPLED THREADED VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS COMPLYING WITH IEC 60034-30 Cod. 191013661 Rev. A Ed.11/2013 CONTENTS General introduction...3

More information

HM - HMZ - HMS Series. 50 Hz

HM - HMZ - HMS Series. 50 Hz 5 Hz HM - HMZ - HMS Series THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE2 MOTORS COMPLYING WITH REGULATION (EC) no. 64/29 Cod. 1913891 Rev ev.b.b Ed.1/212 HM - HMZ - HMS SERIES

More information

HM - HMS Series. 60 Hz

HM - HMS Series. 60 Hz 6 Hz HM - HMS Series THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE2/IE3 MOTORS COMPLYING WITH REGULATION (EC) no. 64/29 Cod. 19113781 Rev ev.b.b Ed.6/212 HM - HMS SERIES HYDRAULIC

More information

The e-gs 4" Range. Lenntech. Tel Fax

The e-gs 4 Range. Lenntech. Tel Fax The e-gs 4" Range e-gs BOREHOLE PORTFOLIO HAS BEEN REDESIGNED WITH OPTIMIZED HYDRAULICS COMPLIANT WITH THE ERP DIRECTIVE. CAPACITIES UP TO 22 m 3 /h HEAD UP TO 31 m POWER UP TO.37 kw TO 7.5 kw Lenntech

More information

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops. OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :

More information

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100 Series A-C 9100 Single Stage Double Suction Large Split Case TECHNICAL Brochure BAC9100 TABLE OF CONTENTS Useful Pump Formulas 2 Pump Engineering Data 3 Materials of Construction 4 Exploded View 6 USEFUL

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating

More information

Xylem VSD Payback Tool

Xylem VSD Payback Tool Xylem VSD Payback Tool Significant opportunities exist to reduce pumping system energy consumption through smart hydraulic system design, retrofitting to variable speed performance and operating practices.

More information

Flygt 3171, 50Hz. Technical Specification

Flygt 3171, 50Hz. Technical Specification Flygt 3171, 50Hz Technical Specification Table of Contents Table of Contents F-pump, Standard Motor...2 Product description...2 Motor rating and performance curves...5 F-pump, Premium Efficiency Motor

More information

e-hm TM Series HM..P - HM..S - HM..N 60 Hz

e-hm TM Series HM..P - HM..S - HM..N 60 Hz 6 Hz e-hm TM Series HM..P - HM..S - HM..N THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS COMPLYING WITH IEC 634-3 Cod. 1911381 Rev. B Ed.3/214 e-hm SERIES HYDRAULIC

More information

In-line Twin Pump. Type Series Booklet. Omega DSL

In-line Twin Pump. Type Series Booklet. Omega DSL In-line Twin Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Rolairtrol Air Separator For Hot and Chilled Water Systems

Rolairtrol Air Separator For Hot and Chilled Water Systems REMOVES ENTRAINED AIR To protect the system against damage To eliminate system noise TANGENTIAL FLOW PATTERN Increases air separation efficiency Allows use of smaller sizes than required with straight

More information

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M. Performance SK75/100 RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6300-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 20 40

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

BOWLING GREEN KITS BG4 AND BG9

BOWLING GREEN KITS BG4 AND BG9 BOWLING GREEN KITS BG4 AND BG9 THE BG4 AND BG9 DESIGNS IN BRIEF The two designs enclosed are two options in watering a bowling green. We have designed both watering system that automatically water twenty-five

More information

Richter Sealless Chemical Magnetic Drive Pumps

Richter Sealless Chemical Magnetic Drive Pumps Richter Sealless Chemical Magnetic Drive Pumps MNK, MNK-B Up to 00 m /h Reinforced plain bearing engagement Linings PFA/PTFE, PFA-L, PE, PFA-P Richter sealless chemical magnetic drive pumps Fields of application

More information

e-hmseries STAINLESS STEEL HORIZONTAL MULTI-STAGE PUMPS BROeHM R2

e-hmseries STAINLESS STEEL HORIZONTAL MULTI-STAGE PUMPS BROeHM R2 e-hmseries STAINLESS STEEL HORIZONTAL MULTI-STAGE PUMPS BROeHM R2 Let s solve your water needs. e-hm is customizable to your applications e-hm bare pump e-hm residential boosters Variable speed systems

More information

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1 Solids: 1/8 GPM: TDH: Performance RPM: 1550 Discharge: 1" Solids: 1/8" Wholesale Products Page: 6660-1 Section: Performance The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower.

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps N N O V A T I O N E F F I C I E N C Y Q U A L I T Y Vertical Sump Pumps For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Calculate the Costs of Piping System Elements

Calculate the Costs of Piping System Elements Calculate the Costs of Piping System Elements by Ray Hardee, Engineered Software, Inc. Last month s column described the process of creating an energy cost balance sheet for a piping system (see Figure

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

Flanged Water Meters (non-continuous flow)

Flanged Water Meters (non-continuous flow) Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30

More information

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 ) PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and

More information

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES: SERIES 4624B (Cast Iron - Replaces Series 4625 Models) Page 410.1 Issue K SERIES DESCRIPTION The Abrasive Liquid Series heavy duty internal gear pumps utilize hard parts in key wear areas, combined with

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

D-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs

D-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs D-35 Series Up to 37 gpm (14 l/min) D-35 Specialized Designs Hydra-Cell Slurry Duty pumps are specifically designed for abrasive slurry applications. See page 72 for complete specifications. The D-35 Hydra-Cell

More information

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2. PERFORMANCE DATA Wholesale Products Page: 6280-1 RPM: 1650 Discharge: 2 Solids: 2 12 40 9 30 HEAD-METERS 6 HEAD-FEET 20 3 10 0 0 Capacity - U.S. G.P.M. 0 30 60 90 120 150 180 Liters/Second 0 2 4 6 8 10

More information

CIVIL/INDUSTRIAL. water solutions. Grey. series SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE, CIVIL AND INDUSTRIAL LIFTING SYSTEMS. zenit.

CIVIL/INDUSTRIAL. water solutions. Grey. series SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE, CIVIL AND INDUSTRIAL LIFTING SYSTEMS. zenit. CIVIL/INDUSTRIAL water solutions Grey zenit.com EN SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE, CIVIL AND INDUSTRIAL LIFTING SYSTEMS series Grey series Why Grey? The Zenit Grey series is a new solution for

More information

N-pump, Standard Motor

N-pump, Standard Motor N-pump, Standard Motor N-pump, Standard Motor Product description Usage Installation type P, S, T, Z Installation type L A submersible pump for efficient pumping of clean water, surface water, and wastewater

More information

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT SMART THINKING WATER ULTRIMIS W ULTRASONIC WATER METER DN15, DN20, D25 i DN32 MID R 800 AMR READY Ultrimis W a state-of-the-art ultrasonic water meter with the very latest patented design features including

More information

Butterfly Valves - Figure 611 & 612

Butterfly Valves - Figure 611 & 612 F611 Wafer style resilient seated bi-directional butterfly valve in sizes 50-300mm to 1600 kpa. F612 Lugged style resilient seated bi-directional butterfly valve in sizes 50-300mm to 1600 kpa. Features

More information

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT PERFORMANCE DATA Wholesale Products Page: 6570-1 RPM: 1550 Discharge: 1 ½ Solids: ½ V-A1 W-A1 D-A1 Head, meters 8 4 Head, feet 30 20 10.3 HP 0 0 Capacity, US GPM 0 10 20 30 40 50 60 liters/second 0.0 1.0

More information

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3) pplication and Type PN pplication for liquids, gases and vapours Ø D 80 BB EN BB SME PN Class 150 suitable for heating, air-conditioning, water supply and cooling installations,for applications where minimum

More information

SECTION PLUMBING PIPING SYSTEMS

SECTION PLUMBING PIPING SYSTEMS SECTION 15300 PLUMBING PIPING SYSTEMS PART 1 - GENERAL 1.01 SPECIAL NOTICE A. Each contractor shall read all relevant documents, become familiar with the job, the scope of work, type of general construction,

More information

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86 High capacity, spring loaded swing type wafer check valve FEATURES Lightweight, wafer type check valve with face-to-face dimensions according ISO 5752, table 5 long High flow capacity featuring a special

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Flow Rate Transmitters/ Flow Switches

Flow Rate Transmitters/ Flow Switches Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate

More information

Dorot Irrigation Meter

Dorot Irrigation Meter DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

INTERNATIONAL STANDARD ISO 4427-2 First edition 2007-08-01 Plastics piping systems Polyethylene (PE) pipes and fittings for water supply Part 2: Pipes Systèmes de canalisations en plastique Tubes et raccords

More information

Introduction. Ultra Reliable

Introduction. Ultra Reliable Introduction Ultra Reliable Engineered for extreme reliability in the most extreme chemical processing applications, Finish Thompson s ULTRAChem is a magnetically driven, ANSI dimensional pump constructed

More information

Goulds Two Stage, Horizontally Split Case Pump

Goulds Two Stage, Horizontally Split Case Pump Goulds 3316 Two Stage, Horizontally Split Case Pump 3316 Two Stage, Horizontally Split Case Pumps designed for boiler feed, mine dewatering and other applications requiring moderately high heads with a

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating and

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

PLUG & PLAY ADD-ONS MEASURE, REPORT AND MANAGE WITH AN INTEGRATED FAMILY OF ADD-ONS

PLUG & PLAY ADD-ONS MEASURE, REPORT AND MANAGE WITH AN INTEGRATED FAMILY OF ADD-ONS PLUG & PLAY ADD-ONS MEASURE, REPORT AND MANAGE WITH AN INTEGRATED FAMILY OF ADD-ONS EASY TO USE PLUG-AND-PLAY ADD-ONS Adding Growsmart by Lindsay sensors to your irrigation system can result in input savings

More information

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Preso s complete line of Venturis offer reduced operating costs, proven accuracy, and great rangeability. Low permanent

More information

NEOTISS TM HPT finned TubES

NEOTISS TM HPT finned TubES NEOTISS TM HPT finned tubes p.2 / NEOTISS NEOTISS / p.3 Nomenclature Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Type 8 Type 9* Material 30 FPI.032 inch.813 mm 28 FPI inch mm 26 FPI inch mm 36 FPI.026

More information

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor lose oupled entrifugal Pumps The electropumps NM, NM, NMS, NMS series comply with the uropean Regulation no. 7/. Materials omponents NM, NMS NM, NMS Pump casing ast iron ronze Lantern bracket NM asing

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,

More information

PN 40 DN 25-40, PN 25 DN 50-80, PN 16 DN Ball seal alternatives Stellite (KC) PTFE (TC) Tightness class ISO 5208, EN RATE D RATE A

PN 40 DN 25-40, PN 25 DN 50-80, PN 16 DN Ball seal alternatives Stellite (KC) PTFE (TC) Tightness class ISO 5208, EN RATE D RATE A Operation WAFER PATTERN V-PORT BALL VALVE stainless steel 5, 501 series C ont R o L Description Edition Högfors ball sector valve series 5 is specially designed for control applications of various media

More information

J.I.C. HYDRAULIC TUBING Seamless & Welded Hydraulic Fluid Line 23 Seamless Burst Pressures & Working Pressures 24 Welded Burst Pressures 25

J.I.C. HYDRAULIC TUBING Seamless & Welded Hydraulic Fluid Line 23 Seamless Burst Pressures & Working Pressures 24 Welded Burst Pressures 25 TABLE OF CONTENTS STEEL & ALLOY ROUND MECHANICAL TUBING Drawn Over Mandrel (DOM) 3-15 Cold Drawn Seamless (CDS) 3-15 Hot Rolled Seamless (HRS) 3-15 Electric Resistance Welded (ERW) 3-15 Seamless 4130/4140

More information

ArcelorMittal Dofasco Scrap Specifications and Requirements

ArcelorMittal Dofasco Scrap Specifications and Requirements ArcelorMittal Dofasco Scrap Specifications and Requirements Revision date: January 2017 Table of Contents Type of Scrap: Auto Cast (Brake Rotors and Drums)... 2 Type of Scrap: Bushelling... 4 Type of Scrap:

More information

Water Quality Specification for Power Supplies

Water Quality Specification for Power Supplies Technical Note #6 Water Quality Specification for Power Supplies Introduction The cooling water for Alpha Scientific Power Supplies must meet certain minimum specifications in regard to quality and flow

More information

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators ARI-STEVI 4 / 441 (DN15-0) Control valve - straight through With pneumatic and electric actuators ARI-STEVI 4 / 441 Pneumatic actuator ARI-DP 32-34 Tri Reversible pneumatic actuator Actuator with rolling

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

Technical specification. Flygt N 3301, 50 Hz

Technical specification. Flygt N 3301, 50 Hz Technical specification Flygt N 3301, 50 Hz 4G50 mm 2 4G70 mm 2 Y/D start SUBCAB 7G6+2x1,5 mm 2 Monitoring equipment Thermal contacts opening temp. 140 C Leakage sensor in inspection chamber FLS Material

More information

GREEN THREAD Piping Systems

GREEN THREAD Piping Systems Bulletin No. A1300 February 15, 2006 SMITH FIBERCAST GREEN THREAD Piping Systems PRODUCT GREEN THREAD pipe is filament wound using an amine cured epoxy resin and fiberglass and has a resin-rich liner reinforced

More information

Model EVMS Vertical Multistage Pumps for the Global Market

Model EVMS Vertical Multistage Pumps for the Global Market New Products & New Techniques Model EVMS Vertical Multistage Pumps for the Global Market Hiroyuki KAWASAKI*, and So KUROIWA* Abstract As key products for the global market, new model EVMS stainless vertical

More information

SECTION SLUDGE HOLDING TANK DECANTER PUMP

SECTION SLUDGE HOLDING TANK DECANTER PUMP PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Sludge Holding Tank Decanter Pumping System in accordance with the

More information

VERTICAL TURBINE PUMPS

VERTICAL TURBINE PUMPS VERTICAL TURBINE PUMPS for the PETROLEUM INDUSTRY www.nationalpumpcompany.com API-610 Vertical Pumps Vertical turbine pumps that meet or exceed API 610 requirements. Since 1969, National Pump Company has

More information

Weir Specialty Pumps. WEMCO Torque-Flow

Weir Specialty Pumps. WEMCO Torque-Flow Weir Specialty Pumps WEMCO Torque-Flow HIGH LOW OIL LEVEL WEMCO Torque-Flow Model C WEMCO Torque-Flow Model C Materials of Construction Ni-Hard, High Chrome Configurations Horizontal Sealing Multiple options

More information

KRAL Volumeter - OMG Series Universal Flowmeters

KRAL Volumeter - OMG Series Universal Flowmeters KRAL Volumeter - OMG Series Universal Flowmeters OMG - Universal OMG Flowmeters for a Wide Range of Applications Operating Conditions and Materials Flow Range: 0.03 to 2000 gpm Max. Pressure: 3600 psi

More information

Spektron UV series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

Spektron UV series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION Spektron UV series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION Let s disinfect drinking water, no matter what. The WEDECO Spektron series shines new light on the environmentally friendly process of

More information

The advantages of Bi-orientation technology and all the PVC qualities OROC.

The advantages of Bi-orientation technology and all the PVC qualities OROC. The advantages of Bi-orientation technology and all the PVC qualities BI OROC PN 16 www.sotra-seperef.com Bi-Orientation Basic principle BI-OROC tubes from SOTRA SEPEREF are manufactured following a specific

More information

ISO INTERNATIONAL STANDARD. Bolted bonnet steel gate valves for the petroleum, petrochemical and allied industries

ISO INTERNATIONAL STANDARD. Bolted bonnet steel gate valves for the petroleum, petrochemical and allied industries INTERNATIONAL STANDARD ISO 10434 Second edition 2004-07-15 Bolted bonnet steel gate valves for the petroleum, petrochemical and allied industries Robinets-vannes en acier à chapeau boulonné pour les industries

More information

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011.

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011. Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011. This is document is (i) a document that relates to a product of the Company

More information

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE.

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. MUNICIPAL SYSTEMS BIONAX PVCO PRESSURE PIPE FOR WATER AND SEWAGE FORCEMAINS, TRANSMISSION AND DISTRIBUTION LINES 4 through 30 (100 to 750 mm) 165, 235 & 305

More information

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment

More information

Glossary Irrigation Terminology

Glossary Irrigation Terminology Glossary Irrigation Terminology ANGLE VALVE A valve configured so its outlet is oriented 90 from its inlet. In irrigation, these valves are generally installed with the inlet at the bottom of the valve.

More information

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL This section covers the furnishing and installation of ductile iron water pipe, fittings, thrust restraint and pipe disinfection. Ductile Iron Pipe MATERIALS

More information

Water Utility Science Water Math and Hydraulics 050. Name: Date:

Water Utility Science Water Math and Hydraulics 050. Name: Date: Water Utility Science Water Math and Hydraulics 050 Name: Date: Note: Please show all of your calculations for each problem no matter how simple the problem may seem. Please use the accompanying pieces

More information

SPILL ESTIMATION. Not Just A Guess Anymore

SPILL ESTIMATION. Not Just A Guess Anymore SPILL ESTIMATION Not Just A Guess Anymore SPILL ESTIMATION Under current regulations accurate spill estimation has become critical to the operation and maintenance of a sanitary collection system Reporting

More information

Sprinkler Identification Numbers (SINs)

Sprinkler Identification Numbers (SINs) Worldwide Contacts www.tyco-fire.com Model 2.8 K-factor Combustible Concealed Space Sprinklers Specific Application, Upright General Description The Model Combustible Concealed Sprinklers are fast response,

More information

SCAN TO VIEW PRODUCT ANIMATION. Universal TS Series ROTARY POSITIVE DISPLACEMENT TWIN SCREW PUMPS

SCAN TO VIEW PRODUCT ANIMATION. Universal TS Series ROTARY POSITIVE DISPLACEMENT TWIN SCREW PUMPS SCAN TO VIEW PRODUCT ANIMATION Universal TS Series ROTARY POSITIVE DISPLACEMENT TWIN SCREW PUMPS Users of Waukesha Cherry-Burrell brand pumps benefit from decades of continuing product improvement. Steady

More information

ECO INSTRUMENT (NS M)

ECO INSTRUMENT (NS M) Computerized AC Servo Control Universal Material Testing Machine Safety Protection Frame Rubber Type 180 degree grip or 90 degree peel fixture Bending Test Compression Test Specimen Gripping Fixture Product

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the contract including general and supplementary conditions and specifications section apply to this section. B. Related Sections:

More information

SECTION PACKAGE BOOSTER PUMP STATIONS

SECTION PACKAGE BOOSTER PUMP STATIONS SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to

More information

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves UL / FM TAPPING VALVE SECTION Rev. 2-15 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D.

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Vertical

More information

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards 2.9. WATER SYSTEM DESIGN Ivins City Standard Specifications for Design and Construction All culinary water mains and appurtenances shall be designed to provide for adequate future service for all contiguous

More information

CEA-CA CEA(N)-CA(N) Series made of AISI 316

CEA-CA CEA(N)-CA(N) Series made of AISI 316 CEA-CA CEA(N)-CA(N) Series made of AISI 316 Single and twin-impeller Centrifugal Electric Pumps equipped with high efficiency PLM motors 60 Hz CEA-CA - CEA(N)-CA(N) SERIES HYDRAULIC PERFORMANCE RANGE AT

More information

Experience In Motion. SIHI ISOchem Chemical Process Pumps with Magnetic Drive

Experience In Motion. SIHI ISOchem Chemical Process Pumps with Magnetic Drive Experience In Motion SIHI ISOchem Chemical Process Pumps with Magnetic Drive Pump Supplier to the World 2 Flowserve is the driving force in the global industrial pump marketplace. No other pump company

More information

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime KEy FEATuRES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime measurements No wet-up or dry-down delays Short term payback;

More information

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

The following document can be provided to an Engineer, Contractor, or Owner to allow them to MESAN series MXL Engineering Guide Specifications The following document can be provided to an Engineer, Contractor, or Owner to allow them to properly specify MESAN s MXL series Cooling Towers. 15XXX-

More information

B U I L D I N G T E C H N O L O G Y. f ri p e x- s a n quick, flexible, reliable and simple

B U I L D I N G T E C H N O L O G Y. f ri p e x- s a n quick, flexible, reliable and simple B U I L D I N G T E C H N O L O G Y f ri p e x- s a n quick, flexible, reliable and simple The plastic pipe: Exceptional water quality Highly resistant to ageing The problems which may occur when metal

More information

Innovation in Joint Restraint Systems for PVC Pressure Pipe and Fittings. Clean & Safe Drinking Water Workshop. Wednesday, March 25, 2015

Innovation in Joint Restraint Systems for PVC Pressure Pipe and Fittings. Clean & Safe Drinking Water Workshop. Wednesday, March 25, 2015 Innovation in Joint Restraint Systems for PVC Pressure Pipe and Fittings Clean & Safe Drinking Water Workshop Wednesday, March 25, 2015 Thrust forces Gasketed joints are made to seal and not to restrain,

More information

MEMORANDUM. The general findings of the assessment are as follows:

MEMORANDUM. The general findings of the assessment are as follows: November 28, 2006 MEMORANDUM Project No.: 030009-002-01 To: From: Re: WRIA 31 Planning Unit Steve Germiat, LHG, CGWP, and Timothy J. Flynn, LHG, CWGP Evaluation of Winterizing Existing River Pump/Conveyance

More information

SECTION SLUICE GATES

SECTION SLUICE GATES SECTION 11100 SLUICE GATES PART 1--GENERAL Fill in the blank with a short description of sluice gate usage, i.e., for isolation of wastewater, or for tank drainage, or for control of water surface. 1.01

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including

More information

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction. General: 1. Construct utilities in accordance to TWA approved plans and shop drawings. Any deviation from the approved plans shall be approved by the DEVELOPER S ENGINEER and TWA 2. A preconstruction meeting

More information

Ref RESILIENT SEAT GATE VALVE ISO PN10-16 F4. Model/Ref:

Ref RESILIENT SEAT GATE VALVE ISO PN10-16 F4.  Model/Ref: Model/Ref: 180-181 - 182 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 600 ISO PN10/16 flanges - 10 C + 110 C with EPDM wedge Max Pressure : 16 Bars up to DN400,

More information

Compact flue gas analyser: testo 300 M-I

Compact flue gas analyser: testo 300 M-I 220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial

More information

Cryogenic Metal Seated Butterfly Valves

Cryogenic Metal Seated Butterfly Valves Cryogenic Metal Seated Butterfly Valves The Key to Cryogenic Valve Solutions VELAN S.A.S VELAN Inc Group VELAN inc is one of the world's leading independent manufacturer of steel gate, globe, check, butterfly

More information