CPRT SERIES 13 SEER PRODUCT SPECIFICATIONS. Split System Heat Pump. 2 to 5 Ton
|
|
- Carol Simmons
- 6 years ago
- Views:
Transcription
1 CPRT SERIES SEER Split System Heat Pump to Ton The CPRT split system heat pump is designed for ground-level or rooftop mount applications. Standard Features High-efficiency Copeland scroll compressor Louvered guard protects coil from damage and adds strength to the unit Bottom pan rails elevate the unit above slab 8-pole, 8-RPM motor -bladed fan Copper tube, aluminum fin coil Brass liquid and suction service valves mounted at a angle with sweat connections and service ports Fully charged for of tubing length Factory-installed liquid line filter drier Discharge line muffler Suction line accumulator Check-flowrater expansion device Time-initiated, temperature-terminated defrost control Low-pressure control for loss-of-charge protection Contactor with lug connection Ground lug connection Cabinet Construction Polyester powder paint provides premium durability and improved UV protection Heavy-gauge, zinc-clad, G9 galvanized steel When properly anchored, meets the Florida Building Code unit integrity requirements for hurricane-type winds Accessories Standard Room Thermostat with -stage cool/-stage heat (HPT8-6) Digital Room Thermostat with -stage cool/ -stage heat (CHTP8-6HD) Outdoor Lockout Thermostat/Emergency Heat Relay Kit for staging electric heat (OT/ EHR8-6) Outdoor Thermostat (OT8-6); required for all heat pumps if outdoor ambient temperature is F with % or higher relative humidity Air Handler and Coil Compatibilities AEPT, ARPT and ARUF multi-position electric heat air handlers MBR/MBE modular blower CA, CH and H indoor coils SS-GCPRT 7/ Supercedes /
2 Specifications Model CPRT- CPRT- CPRT6- CPRT- CPRT8- CPRT6- Service Valve Liquid /8 /8 /8 /8 /8 /8 Suction / / 7/8 7/8 7/8 7/8 Type Sweat Sweat Sweat Sweat Sweat Sweat Shipping Weight (lbs) Volts 8/ 8/ 8/ 8/ 8/ 8/ Phase Electrical Data Hz Minimum Circuit Amps Maximum Overcurrent Protection Minimum Volts Maximum Volts Compressor Condenser Fan RLA LRA FLA HP /6 /6 /6 /6 /6 /6 ) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ) May use fuses or HACR type Circuit Breakers of the same size as noted SS-GCPRT
3 Dimensions for CPRT- Models 9" 9" CPRT = " CPRT = " CPRT6 = 7." CPRT = " ADDITIONAL -/" ELEVATED CHANNEL FORMED INTO BOTTOM PAN LIQUID CONN. SUCTION CONN. -/8" DIA. POWER 7/8" DIA. CONTROL SS-GCPRT
4 Dimensions for CPRT8-6 Models."." CPRT8- = " CPRT6- = " -/8" DIA. POWER 7/8" DIA. CONTROL ADDITIONAL -/" ELEVATED CHANNEL FORMED INTO BOTTOM PAN SUCTION CONN. LIQUID CONN. SS-GCPRT
5 Performance Ratings PRODUCT SPECIFICATIONS Model Coil / Air Handler Total BTUH Cooling Capacity Sensible BTUH SEER EER 7 F (BTUH) Heating Capacity 7 F HSPF 7 F (BTUH) 7 F ARI Ref. # Decibels AEPT-*-*,8 7,.6,. 7.,. 969 ARPT-*-*,8 7,.6,. 7.7,. 97 CPRT- ARUF-*-*,8 7,.6,. 7.7,. 976 CA*F**+EEP,8 7,.6,. 7., CA*F**+EEP,8 7,.6,. 7., CHPFA*+EEP,8 7,.6,. 7., CHPFB*+EEP,8 7,.6,. 7., H6F+EEP,8 7,.6,. 7.,. 977 AEPT-*-* 9,,.,. 8 8,. 9 AEPT6-*-*, 6,.,. 8. 9, ARPT-*-* 9,,.6,. 8 8,. 98 CPRT- ARUF-*-* 9,,.6,. 8 8,. 9 CA*F**+EEP,,.6, ,. 976 CA*F**+EEP,,.6, ,. 97 CHPFA*+EEP,,.6, ,. 977 CHPFB*+EEP,,.6, ,. 97 H6F+EEP 9,,.6, ,. 976 AEPT6-*-*,,.6 7,. 8.,. 978 ARPT9-*-*,,.6 6,. 8, CPRT6- ARUF8-*-*,,.6 6,. 8,. 989 ARUF9-*-*,,.6 6,. 8,. 977 CA*F8**+EEP,,.6 6,.8 8, CHPF8D*+EEP,,.6 6,.8 8, H6F+EEP,,.6 6,. 8,. 9 ) Certifi ed per ARI 8 F/67 F/9 F ) TVA Rating ) Seasonal Energy Effi ciency Ratio ) Energy Effi ciency 8 F/67 F/9 F ) HSPF = Heating Seasonal Performance Factor 6) Order the EEP from the Service Department using Part No. B77-8 or new Solid State Board B77-S. Part No. B77-8 is not interchangeable with B77-S. XX designates electric heat quantity When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size. SS-GCPRT
6 Performance Ratings Model Coil / Air Handler Total BTUH Cooling Capacity Sensible BTUH SEER EER 7 F (BTUH) Heating Capacity 7 F HSPF 7 F (BTUH) 7 F ARI Ref. # Decibels AEPT6-*-*,,.6,.8 8.,. 97 CPRT- ARPT9-*-* 9, 9,6.6,.6 8.,. 9 ARUF9-*-* 9, 9,6.6,.6 8.,. 98 CA*F6**+EEP 9, 9,6.6,.6 8., CHPF6D*+EEP 9, 9,6.6,.6 8.,.8 97 H6F+EEP 9, 9,6.6,.6 8.,. 986 AEPT6-*-* 6,,. 6,. 8.6,.6 ARPT6-*-* 6,,.6 6,. 8.,. 9 CPRT8- ARUF6-*-* 6,,.6 6,. 8.,. CA*F8**+EEP,,6.6,.8 8 8,.8 CA*F6**+EEP,,., ,.8 9 CA*F6**+EEP 6,,.6,.8 8., CHPF6D*+EEP 6,,.6,.8 8.,.8 H6F+EEP 6,,.6,. 8.,. 6 AEPT6-*-*,,.6,. 8.,.6 CPRT6- ARPT6-*-*,,.6,. 8.,. ARUF6-*-*,,.6,. 8.,. 7 CA*F6**+EEP, 9,.6,. 8.,. 8 CHPF6D*+EEP, 9,.6,.8 8.,. H6F+EEP, 9,.6,. 8.,. ) Certifi ed per ARI 8 F/67 F/9 F ) TVA Rating ) Seasonal Energy Effi ciency Ratio ) Energy Effi ciency 8 F/67 F/9 F ) HSPF = Heating Seasonal Performance Factor 6) Order the EEP from the Service Department using Part No. B77-8 or new Solid State Board B77-S. Part No. B77-8 is not interchangeable with B77-S. XX designates electric heat quantity When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size. 6 SS-GCPRT
7 Heating Performance Expanded 7 F Indoor Ambient PRODUCT SPECIFICATIONS CP*T- VS. U/ UC+EEP, U/ UC+EEP, H 6 F + E EP, ARPF6, A RPT, ARUF CP* T - VS. AEPT, AEXX CP* T - VS. U/ UC+EEP, U/UC+EEP, H 6F + E E P, ARPF6, AR PT, ARUF CP * T - V S. AEPT/AE-XX CP * T - V S. AEPT6/AE6 -XX C P * T 6 - VS. U / U C 9 + E E P, H 6 F + EEP, ARUF8 OU T S I D E de g F 6 C P * T 6 - V S. AEPT6/AE6-XX C P * T - VS. U / U C 6 + EEP, H 6 F +EEP, ARPF8, ARPT9, ARUF9 C P * T - V S. AEPT8/AE8-XX C P * T 8- V S. U/ U C 6+ E E P, H 6F + E E P C P * T 8 - VS. ARPF6, ARPT6, ARUF6 C P * T 8 - V S. A E / /AEPT6 7 6 TI NG C P * T 6- V S. U / U C 6+ E E P, H 6F + E E P CP * T 6 - V S. ARPF6, ARPT6, ARUF6 C P * T 6 - VS. A E /AEPT OU T S I D E de g F OU T S I D E de g F HEA TING BTUH SS-GCPRT 7
8 Goodman Manufacturing Co., L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright Goodman Manufacturing Co, L.P. Houston, Texas Goodman brand products are made proudly in the USA. Printed in the USA. 8 SS-GCPRT
EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18.
ENVIRONMENTALLY SOUND REFRIGERANT H4A3 Product Specifications EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 3 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 3 phase, 60 Hz
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...
More informationAIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology
AIR CONDTIONERS XC16 ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology E N G I N E E R I N G D ATA Bulletin 210465 October 2009 Supersedes March 2009 SEER up to 17.20 2 to 5 Tons Cooling
More informationMHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3
MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model
More informationAir Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard
More informationProduct Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)
38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons Product Data Carrier s air-cooled air conditioning split systems: S provide a logical solution for commercial needs S have
More informationMV Product Specifications
MODULAR VARIABLE SPEED BLOWER CABINET 2, 3, 4, and 5 TONS FEATURES Variable Speed modular blower Supports two-stage outdoor units Dehumidification Speed: 80% Airflow Efficient low continuous fan selection:
More informationProduct Specifications
Product Specifications MODULAR ELECTRIC FURNACE 2, 3,4,and5TONS FEATURES S Modular Blower Cabinet, Air Conditioning or Heat Pump ready S Upflow, horizontal right or left applications S Downflow requires
More informationBLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES
BLOWER COILS 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Grooved copper tubing Lanced sine--wave aluminum fin Fully wettable
More informationACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features
ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw YKN2open Features High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating +
More informationProduct Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS
Z / D 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons Product Data FEATURES / BENEFITS Z07-14 shown C09227 the environmentally sound refrigerant Carrier s air-cooled air
More informationAir Cooled Condensing Units - Technical Catalog. Featuring Copeland TM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Copeland TM s 0A and 507 Refrigerants 9 Hunt St - Pryor, OK 736-98.85.7 - Fax 800.6.539 - www.century-refrigeration.com Standard Features
More informationCabinet Features Heavy-gauge, galvanizedsteel. powder-paint finish Full perimeter rail Sloped drain pan Easy to service
DG ommercial 7½- TO ½-TON THREE-PHASE PAKAGED GAS/ ELETRI UP TO. EER / 80% AUE ooling apacity: 88,000,000 BTU/h Heating apacity (Output): 68,000 BTU/h ontents Nomenclature... Product Specifications...
More information4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT
DHP MULTI-ZONE PRODUCT SPECIFICATIONS UP TO SEER UP TO DUCTLESS HEAT PUMP SYSTEMS UNITS FORM NO. DHPMULTI-00 (0/07) DHP MULTI-ZONE 8K / 0K / 6K / 8K Mid Efficiency (- SEER) Matches with all indoor units
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationBLOWER COILS COMMERCIAL
BLOWER COILS COMMERCIAL 2 THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Listed By Underwriters Laboratories Grooved copper tubing
More informationRDI Systems. Scroll Series Refrigeration System. Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models
RDI Systems Scroll Series Refrigeration System Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models PC Refrigeration Systems The RDI PC Refrigeration system includes an RDI condensing
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationDVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons
DVPTC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons Contents Air Handler Nomenclature...2 Heater Kit Nomenclature...2 Product Specifications...3
More informationFiberglass Cooling Towers
Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality
More informationProduct Data. (Unit shown with optional economizer.)
COOLING ONLY/ELECTRIC HEAT PACKAGED ROOFTOP UNIT 15 TO 27.5 NOMINAL TONS Product Data (Unit shown with optional economizer.) C09316 Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationB. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationAir Conditioners. Technical Data. Pair application EEDEN RXS-J
Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................
More informationInstallation Instructions
Installation Instructions AquaSnap 010-055 Chilled Water Storage Tank 50/60 Hz Part No: -900---001; -900---009; -900---010 CONTENTS INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................
More informationYORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM
YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATORS Regardless of building type or rating system, today s building must be as energy
More information120 Series Refrigeration Systems
120 Series Refrigeration Systems RDI Systems Air Cooled Indoor/Outdoor Condensing Units Hermetic / Scroll / Semi-Hermetic ½ thru 6 Hp s PC Refrigeration Systems The RDI PC Refrigeration system includes
More informationSTART-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:
START-UP INSTRUCTION SERIES 20 J**YC/YD 90000 To 300000 BTU S SPLIT SYSTEM CONDENSING UNITS 7.5 To 25 TON START-UP CHECKLIST Date: _ Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial
More informationProduct Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.
Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09262 the environmentally sound refrigerant This product has been designed and manufactured
More informationEnergy Savers: Air-Source Heat Pumps
1 of 5 4/25/2009 8:55 AM U.S. Department of Energy - Energy Efficiency and Renewable Energy Energy Savers Air-Source Heat Pumps An air-source heat pump can provide efficient heating and cooling for your
More informationTECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)
TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used
More informationl a t i t u d s e r i e s A I R C O N D I T I O N E R S & H E A T P U M P S
l a t i t u d e s e r i e s A I R C O N D I T I O N E R S & H E A T P U M P S Life is always better when you have choices. That s what makes your home so unique and cozy. That s also why millions of families
More informationAir Cooled Packaged Air Conditioning
Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated
More informationPARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two
Marine/Industrial Single Package Design Series One, Beginning Serial Number C96741 & Design Series Two 62-10404 -01 PARTS LIST Service Parts List SINGLE PACKAGE COOLING UNIT Design Series One, Beginning
More informationProduct Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.
Product Catalog Variable Refrigerant Flow (VRF) System Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH/4TVR0072 0192 4TVH/4TVR0216 0528 Single Unit Modules Multi-Unit Modules January 2016 VRF-PRC008C-EN
More informationAQUAROBIC MINI-PLANT TM
AQUAROBIC MINI-PLANT TM Process Description The Mini-Plant TM is a Sequential Batch Reactor (SBR) system, controlled by a factory set programmer that regulates aeration, settling, and pump functions. The
More information2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment
ANSI/AHRI Standard 1230 with Addendum 2 2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment Approved by ANSI on 2 August 2010 ANSI/AHRI
More informationCool Smart Incremental Cost Study: Final Report
Cool Smart Cost Study: Final Report July 2015 Prepared for: The Electric and Gas Program Administrators of Massachusetts Part of the Residential Evaluation Program Area This page left blank. Prepared by:
More informationProduct Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.) C09248
Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 the environmentally sound refrigerant This product has been designed and manufactured
More informationAttachment 1: RAE Corporation Technical Specification
Attachment 1: RAE Corporation Technical Specification RAE Corporation Phone: 918-825-7222, ext. 105 Steve Corbin Quote# XXXX Qty Customer Tag Technical Systems Model Number 1 ACC-4 10A0-162-S General Scope
More informationGuide Specifications. Landmark Rooftop Units. Packaged Outdoor HVAC Equipment. May 18, 2017
Packaged Outdoor HVAC Equipment Guide Specifications Landmark Rooftop Units May 18, 2017 Note: This specification specifies Lennox Industries Landmark Rooftop Units. Revise specification section number
More informationa f f i n i t y s e r i e s C O M M E R C I A L P A C K A G E D S Y S T E M S
a f f i n i t y s e r i e s C O M M E R C I A L P A C K A G E D S Y S T E M S Comfortable, efficient and quiet that s what you want in any heating and cooling system. But just any system won t cut it.
More informationYORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE
YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE Contents YORK Bulkhead Active Chilled Beams 3 CB-ABB-YK / CB-ABC-YK Performance Data 5 CB-ABB-YK Dimensions 10 CB-ABC-YK Dimensions 11 Specifications
More informationGLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems
Energieeffizient, Energy efficient, kompakt compact, und and variantenreich versatile GLAC0524- - 1204BD2 Luftgekühlte Air cooled Kaltwassererzeuger Chiller Data Daten && Facts Fakten Lufttechnik GEA Heat
More informationSpecifying... Or Equal
This article was published in ASHRAE Journal, August 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More information22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING
22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your home remains
More informationAK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :
ROOM AIR CONDITIONER AK SERIES (50Hz) Models : AKY9FBSSW AKY9UBSSW CONTENTS SPECIFICATIONS.......................... CIRCUIT DIAGRAM........................ MICROCOMPUTER CONTROL CIRCUIT...... DISASSEMBLY
More informationUNITARY SMALL AIR-CONDITIONERS AND AIR-SOURCE HEAT PUMPS (INCLUDES MIXED-MATCH COILS) (RATED BELOW 65,000 BTU/H) CERTIFICATION PROGRAM
UNITARY SMALL AIR-CONDITIONERS AND AIR-SOURCE HEAT PUMPS (INCLUDES MIXED-MATCH COILS) (RATED BELOW 65,000 BTU/H) CERTIFICATION PROGRAM USE AHRI OM JANUARY 2018 2111 Wilson Blvd, Suite 500 Arlington, Virginia
More informationTM Series Cooling Tower Specification
1.0 Cooling Tower TM Series Cooling Tower Specification 1.1 General: Furnish and install factory-assembled, induced draft, counterflow cooling tower(s) with vertical air discharge conforming in all aspects
More informationUnit Coolers SKB. 4 kw 30,5 kw.
Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...
More informationDaikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS
Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS 1.5 & 2 TON, 2 & 3 ZONE SYSTEMS Up to 17.9 SEER / 12.5 HSPF / 12.7 EER INVERTER, VARIABLE SPEED COMPRESSOR Flexible options providing high efficiency
More informationDaikin AURORA SINGLE ZONE HEATING & COOLING SYSTEMS WALL MOUNTED UNITS Up to 20 SEER / 12.5 HSPF / 13 EER INVERTER, VARIABLE SPEED COMPRESSOR
Daikin AURORA SINGLE ZONE HEATING & COOLING SYSTEMS WALL MOUNTED UNITS Up to 20 SEER / 12.5 HSPF / 13 EER INVERTER, VARIABLE SPEED COMPRESSOR Today, the air is perfect. Perfect temperature. Perfect humidity.
More information5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationProduct Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with optional economizer.
Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationtechnical data air conditioning systems RKS-F2V1B Split Sky Air
technical data RKS-F2VB air conditioning systems Split Sky Air Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe
More informationVARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM
VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM VRF OM JANUARY 2018 2111 Wilson Boulevard, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored and administered
More informationAS950 ALL-WEATHER REFRIGERATED SAMPLER
AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller
More informationSECTION COOLING TOWER
PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue
More informationGeothermal Comfort Systems
Frequently Asked Questions Q: How efficient are geothermal heat pump systems? A: Actual efficiencies will depend on a number of factors, but generally speaking a geothermal heat pump can be three to five
More informationACBC Floor Mounted Active Beam
Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS
More informationB. Shop Drawings: For air terminal units. Include plans, elevations, sections, details, and attachments to other work.
SECTION 233600 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units. 2. Shutoff, single-duct air terminal units. 1.2 PERFORMANCE REQUIREMENTS A. Structural Performance:
More informationLarge University Central Chiller Plant Design Considerations
Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful
More information50KC Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613
Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS & ACCESSORIES...
More informationCONSTRUCTION REQUIREMENTS
CONSTRUCTION REQUIREMENTS Note: The buildings on the UCCS campus are divided into two categories: General Fund and Auxiliaries. General Fund Buildings include academic and administrative functions. Auxiliary
More informationLight commercial rooftop units Retail applications
Light commercial rooftop units Retail applications Less to install. Less to maintain. Less to operate. installations and retrofits. Unit efficiency surpasses EER minimum by 12%. Precedent high-efficiency
More informationMUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA
SPLIT-TYPE AIR CONDITIONERS Revision F: MUZ-GE//5, MUZ-GE//5NAH and MUY-GE//5 have been added. Please void OBB549 REVISED EDITION-E. OUTDOOR UNIT PARTS CATALOG No. OBB549 REVISED EDITION-F Models MUZ-GENA
More informationMechanical Product Overview
Mechanical Product Overview The founding principles of Price have never changed business integrity, first class service, innovation and a commitment to people. PURPOSE BUILT FOR YOUR APPLICATION Whether
More informationVRF 50/60Hz V5 E Series
1702-1V1701 VRF 50/60Hz V5 E Series Coercial Air Conditioners 2017/2018 VRF 50/60Hz V5 E Series Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde,
More information30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING
30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE B NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your home remains
More informationRebel commercial packaged rooftop systems
Rebel commercial packaged rooftop systems Advanced technologies propel performance and energy savings to uncommon levels 3-28 tons Rebel features and benefits 18 13 6 5 3 6 4 43% Energy Savings 5 11 12
More informationSECTION SLUDGE HOLDING TANK DECANTER PUMP
PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Sludge Holding Tank Decanter Pumping System in accordance with the
More informationTrane Precedent 3- to 10-ton light commercial rooftop units
Trane Precedent 3- to 10-ton light commercial rooftop units The right size for high comfort. The lowest installed cost and lowest total Most Trane Precedent rooftop units can be ready in as few as two
More informationRoof top. NEW SPACE Zen attitude NA O8.16B
u n i v e r s a l c o m f o r t Roof top NEW SPACE Zen attitude NA O8.16B sustainable development CIAT - YOUR EXPERT IN SUSTAINABLE SOLUTIONS CIAT is an expert in environmentally sound solutions that use
More informationOptimizing the Features of a Customizable Air-Cooled Chiller
Carrier Engineering Newsletter Volume 5, Issue 2 Optimizing the Features of a Customizable Air-Cooled Chiller The use of air-cooled chillers in process and comfort cooling applications has been steadily
More informationQuick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010
Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:
More information00 SYLLABUS (rev.01/6/2014)
Austin Community College Heating, Air Conditioning & Refrigeration Technology HART2449 HEAT PUMPS 00 SYLLABUS (rev.01/6/2014) Course Description: a study of heat pumps, heat pump control circuits, defrost
More informationProduct Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.
Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems
More informationDCG COMMERCIAL. Standard Features. Contents. Cabinet Features. SS-DCG7 7/13
DG OMMERIAL Standard eatures abinet eatures - 7½- TO ½-TON THREE-PHASE PAKAGED GAS/ ELETRI UP TO. EER / 80% AUE ooling apacity: 88,000 44,000 BTU/h Heating apacity (Output): 68,000 BTU/h ontents 7 9 SS-DG7
More informationFlorida Department of Agriculture and Consumer Services
Florida Department of Agriculture and Consumer Services FOOD SAFETY BSL-3 HVAC IMPROVEMENTS Doyle Conner Laboratory Complex Tallahassee, Florida Project Technical Specifications Construction Documents
More informationMINIMUM SPECIFICATIONS
MINIMUM SPECIFICATIONS A) GREENHOUSE STRUCTURE: (EDUCATOR) 30 X 96 Galvanized Steel Frame Consisting of: A. Column Post: Allied 2 x 4 Rectangle 6 Spacing B. Bows: Allied 2 x 3 Rectangle 6 Spacing C. Trusses:
More informationJones Residence Energy Cost Analysis
Jones Residence Energy Analysis for Mr. and Mrs. Joe Jones 1234 First Street Warmnister, Pa 18974 Prepared By: Jeffrey A. Smith J.A. Smith Heating & Air Cond Inc 360 Patricia Drive Warminster, Pa 18974
More informationCLCF Climate Changer for comfort applications. Next generation air handling performance from Trane
CLCF Climate Changer for comfort applications Next generation air handling performance from Trane Customized performance and maximum comfort at minimum cost For many years Trane has been a global leader
More informationExperimental Investigation of Vapor Injected Compression for Cold Climate Heat Pumps ABSTRACT
2111, Page 1 Experimental Investigation of Vapor Injected Compression for Cold Climate Heat Pumps Christian K. BACH 1 *, Bernhard VETSCH 2, Eckhard A. GROLL 1, James E. BRAUN 1, W. Travis HORTON 1 1 Purdue
More informationBard Manufacturing. Classroom Preferred
Bard Manufacturing. Classroom Preferred School HVAC Solutions. Climate Control Solutions History Lessons. Bard Manufacturing has been in business since 1914. Our history has taught us what it takes to
More informationMarine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information
/2 Orientation /2 Overview /3 Benefits /3 Application /3 Technical specifications /5 More information /6 Type approved standard motors up to frame size 315 L /6 Overview /7 Type approved explosion-proof
More informationStandardizing Smart/Connected Products in a Highly Innovative and Dynamic Market
Standardizing Smart/Connected Products in a Highly Innovative and Dynamic Market Robert Wilkins Thursday, September 15, 2016 10:00 a.m. 10:30 a.m. AHRI One of the nation s larger trade associations including
More informationPoint Eight Power, Inc. Switchgear Specification Low Voltage UL 1558 Metal-Enclosed Switchgear
Table of Content 1.0 General... 2 2.0 Scope... 2 3.0 Applicable Codes, Standards and Qualifications... 2 4.0 Service and Environmental Conditions... 3 5.0 Construction... 3 6.0 Front Breaker Compartment
More informationRESIDENTIAL & COMMERCIAL LABOR CONCESSIONS PROCEDURES
RESIDENTIAL & COMMERCIAL LABOR CONCESSIONS PROCEDURES TABLE OF CONTENTS COMMERCIAL & RESIDENTIAL LABOR STATEMENT 3 COMMERCIAL LABOR ALLOWANCES 4 RESIDENTIAL LABOR ALLOWANCES 5 COMMERCIAL ALLIED LABOR
More informationDIN Panels and Accessories
DIN Panels and Accessories The Lutron myroomtm and HomeWorks QS families of DIN rail panels are designed to accept DIN Power Modules (DPMs). The DPMs can be configured in the panel to control multiple
More informationSECTION INFLUENT EQUALIZATION TANK PUMPS
PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Influent Equalization Pumps in accordance with the Contract Drawings
More informationThe following document can be provided to an Engineer, Contractor, or Owner to allow them to
MESAN series MXL Engineering Guide Specifications The following document can be provided to an Engineer, Contractor, or Owner to allow them to properly specify MESAN s MXL series Cooling Towers. 15XXX-
More informationB. Provide liquid-filled secondary substation transformers as indicated on drawings.
SECTION 26 12 13 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 26 05 00. B. Provide liquid-filled secondary substation transformers as indicated on drawings. 1.02 RELATED
More informationAn Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationTRANQUILITY WATER-TO-WATER SERIES
TRANQUILITY WATER-TO-WATER SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your
More informationThe most reliable and longest lasting in the industry.*
Heat Pumps The most reliable and longest lasting in the industry.* Extreme is not even close to our approach to product testing. Cruel and unusual may be a better way to describe what a Trane endures to
More informationSECTION ROTARY SCREW WATER CHILLERS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More informationSt. Clair County Road Commission. For Turn Key Replacement of the Existing Chilled Water System Page 1 of 6
Page 1 of 6 NOTICE IS HEREBY GIVEN THAT SEALED PROPOSALS ARE SOUGHT AND REQUESTED FOR THE FOLLOWING: BID NAME: TURN KEY REPLACEMENT OF THE EXISTING CHILLED WATER SYSTEM BID OPENING: JANUARY 15, 2015 1:00
More informationSECTION PACKAGE BOOSTER PUMP STATIONS
SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to
More informationRL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL
The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More information