Product Specifications
|
|
- Francine Dennis
- 6 years ago
- Views:
Transcription
1 Product Specifications MODULAR ELECTRIC FURNACE 2, 3,4,and5TONS FEATURES S Modular Blower Cabinet, Air Conditioning or Heat Pump ready S Upflow, horizontal right or left applications S Downflow requires sub--base accessory S Electronic fan control board S Three speed PSC motor on all models S Matches with AC and HP cased coils (Hot water coil may be used, but doesn t match case size) S Accepts accessory two stage outdoor thermostats S Field installed electric heater packages from 5 kw kw available separately S / supply voltage SERVICE S Direct drive slide--out blower assembly QUALITY S Internally lined with ½ Tuf--Skin II insulation S Prepainted galvanized steel cabinet WARRANTY S 5 year limited parts warranty ACCESSORY HEATER S UL listed for sale in U.S.A. and Canada S Easy to install with simple 9--pin plug in connection to Modular Blower Cabinet S Designed for / Volt S Single & three--phase models S Breakerless 5, 7.5, and 10 nominal kw models available S 5, 7.5, 10, 15, 20, and 25 nominal kw models available with Circuit Breakers S Auto--reset high temperature limits S Requires a NO HEAT KIT if installed without electric heat. Nominal Tons Nominal CFM Motor HP 08B1500B /3 12F1900B /2 16J2200B /2 20L2400B /4 Rated in accordance with ARI Standard 210 and/ or 240. Certification applies only when used with proper components as listed with ARI. Dimensions H x W x D in (mm) 24 x 152 x202 (610 x 394 x 521) 24 x 198 x202 (610 x 495 x 521) 24 x 22w x202 (610 x 578 x 521) 24 x 242 x202 (610 x 622 x 521) Unit Weight lbs/kg Ship Weight lbs/kg 56/25 59/27 62/28 67/30 67/30 73/33 70/32 78/ Dec 2007
2 UNIT SPECIFICATIONS - ELECTRIC FURNACE Number 08B1500B1 12F1900B1 16J2200B1 20L2400B1 Application Upflow / Horizontal / Downflow * Electrical Volts--Phase--Hz. / Data ** Minimum Circuit Ampacity Time Delay Fuse (Amps) 15 Max Fuse or Breaker Size (Amps) 15 Blower Size DD DD DD DD Data Horsepower -- Speed 1/ / / / Full Load Rated (Amps) Transformer 40 VA Weight Unit / Shipping Lbs (Kg) 56/25 (59/27) 62/67 (28/30) 70/78 (32/35) 70/78 (32/35) * Accessory subbase kit required for downflow application ** Disregard if electric heat is added. Refer to Electric Heat table. NOMINAL INSTALLATION DIMENSIONS AND CLEARANCES 14a (2-22 Ton) 17d (3-32 Ton) 212 (4 Ton) 238 (5 Ton) 3/4 CLEARANCES Voltage Entrance 5/8 NO HEATERS All Sides... 0 From Supply Duct... 0 Service From Front (Service for blower, filter if installed) 15w (2-22 Ton) 194 (3-32 Ton) 22d (4 Ton) 242 (5 Ton) Line Voltage Entrance 8 1 / WITH HEATERS All Sides... 0 From First Three Feet of Supply Duct to Combustibles... 1 From Duct after Three Feet... 0 Service From Front (Service for blower, heaters if installed) 20 1 / 2 ALL DIMENSIONS IN INCHES 1IN=25.4MM MODEL NUMBER IDENTIFICATION GUIDE PRODUCT FAMILY M = MODULAR M F 12 F19 00 B 1 SERIES SALES CODES B = MODULAR BLOWER (115V) F = MODULAR ELECTRIC FURNACE (/V) V = MODULAR VARIABLE SPEED BLOWER (/V) FIELD INSTALLED HEATER NOMINAL CFM RANGE COIL WIDTH MATCH 08 = 800 B15 = 152 Cabinet 12 = 1200 F19 = 198 Cabinet 16 = 1600 J22 = 22w Cabinet 20 = 2000 L24 = 242 Cabinet
3 Airflow based on no coil, no filter, no electric heat (pre--accessory external static pressure). When heaters, filters, horizontal drain pan and/or downflow subbase are installed in an application, airflow must be re--calculated by adding the heater static, filter static, and coil static pressures (provided in the following tables) to the pre--accessory external static amount. See Coil Specification Sheet. Add.10 for Horizontal Drain Pan Kit. Add.20 for Downflow Subbase Kit. AIRFLOW IS BLOWER ONLY, NO COIL ATTACHED 08 v v v v v v v v v v v v v v v v v v v v v v v v FILTER STATIC PRESSURE DROP WASHABLE NOMINAL CFM FILTER SIZE DISPOSABLE MODEL FILTER SIZE / 4 x20 1 / 4 14 x / 4 x20 1 / 4 18 x / 4 x20 1 / 4 20 x / 4 x20 1 / 4 24 x
4 HEATER STATIC TABLE HEATER KW / STATIC DROP Single -Phase CFM EHIA05 EHIA07 EHIA10 EHIA15 EHIA20 EHIA Three -Phase CFM EHIA10 EHIA15 EHIA20 EHIA DO NOT OPERATE IN THIS AREA CFM / KW LIMIT EXCEEDED UNIT SPECIFICATIONS - No Heat Kit Supply Circuit No Heat Kit EHIA00KN10 Table 1 08* 12* 16* 20* Volts Phase Hertz Supply Circuit No. HP Max. Motor Amps MCA Branch Circuit AMP Max Overcurrent Protection Devise (Amps) #of Wires Supply Wire Ground Wire 75 C copper Wire Size Max. Ft. Length #of Wires 1 60 Single 1/ Single 1/ Single 1/ Single 3/ * Modular blower without electric heat Conversion: 1 foot =.305 meters Min Wire Size
5 TECHNICAL DATA Single Phase with Circuit Breaker Maximum MCA Overcur- Supply Wire Ground Nom. Supply Heater Max FLA Min Protective 75 0 C. Copper Wire Heater Supply Heati Heat kw Per Circuit kw Per Heater Motor Total Circuit Device #of Wire Max. #of Min Volt- BTUH KW Element No. Circuit AMPS. AMPS. AMPS. Ampacity (AMPS.) Wires Size Length (Ft) Wires Size EHIA05KB Single Single EHIA07KB10 EHIA10KB10 EHIA15KB10 EHIA20KB10 EHIA25KB Single Single Single Single Single Mult Mult Single Mult Mult Single Mult Mult Single Mult Mult Single / Mult Mult Single Mult Mult TECHNICAL DATA Single -Phase with Terminal Block Maximum MCA Overcur- Supply Wire Ground Nom. Supply Heater Max FLA Min Protective 75 0 C. Copper Wire Heater Supply Heati Heat kw Per Circuit kw Per Heater Motor Total Circuit Device #of Wire Max. #of Min Volt- BTUH KW Element No. Circuit AMPS. AMPS. AMPS. Ampacity (AMPS.) Wires Size Length (Ft) Wires Size EHIA05KN Single Single EHIA07KN Single Single EHIA10KN Single Single TECHNICAL DATA Three Phase with Circuit Breaker Maximum MCA Overcur- Supply Wire Ground Nom. Supply Heater Max FLA Min Protective 75 0 C. Copper Wire Heater Supply Heati Heat kw Per Circuit kw Per Heater Motor Total Circuit Device #of Wire Max. #of Min Volt- BTUH KW Element No. Circuit AMPS. AMPS. AMPS. Ampacity (AMPS.) Wires Size Length (Ft) Wires Size EHIA10HB Single Single EHIA15HB Single Single Single Mult EHIA20HB10 Mult Single Mult Mult Single Mult EHIA25HB10 Mult Single Mult Mult Conversion: 1 foot =.305 meters
6 HEATER STAGING Single -Phase ELECTRIC HEATER VOLTAGE TOTALHEATKW 1st STAGE KW (W1) 2nd STAGE KW (W2) V 240V V 240V V 240V EHIA05KB /1/ EHIA07KB /1/ EHIA10KB /1/ EHIA15KB /1/ EHIA20KB /1/ EHIA25KB /1/ EHIA05KN /1/ EHIA07KN /1/ EHIA10KN /1/ Three -Phase ELECTRIC HEATER VOLTAGE TOTALHEATKW 1st STAGE KW (W1) 2nd STAGE KW (W2) v 240v v 240v v 240v EHIA10HB /3/ EHIA15HB /3/ EHIA20HB /3/ EHIA25HB /3/ Conversion: 1 foot =.305 meters HEAT STRIP STAGING Single--Stage Operation Single--Phase Three--Phase (no staging -- all electric heat together) EHIA05KB / KN EHIA07KB / KN EHIA10KB / KN EHIA15KB EHIA20KB EHIA25KB EHIA10HB EHIA15HB EHIA20HB EHIA25HB Two--Stage Capable EHIA15KB EHIA20KB EHIA25KB EHIA10HB EHIA15HB EHIA20HB EHIA25HB Three--Stage Capable (with ODTS only) EHIA25KB EHIA20HB EHIA25HB ACCESSORIES EHAI00KN10 No Heat Kit 08, 12, 16, 20 EHIA05KB10 5kW1--Phasew/C.B. 08, 12, 16, 20 EHIA05KN10 5kW1--Phasew/T.B. 08, 12, 16, 20 EHIA07KB kw 1--Phase w/c.b. 08, 12, 16, 20 EHIA07KN kw 1--Phase w/t.b. 08, 12, 16, 20 EHIA10KB10 10 kw 1--Phase w/c.b. 08, 12, 16, 20 EHIA10KN10 10 kw 1--Phase w/t.b. 08, 12, 16, 20 EHIA15KB10 15 kw 1--Phase w/c.b. 08, 12, 16, 20 EHIA20KB10 20 kw 1--Phase w/c.b. 12, 16, 20 EHIA25KB10 25 kw 1--Phase w/c.b. 16, 20 EHIA10HB10 10 kw 3--Phase w/c.b. 12, 16, 20 EHIA15HB10 15 kw 3--Phase w/c.b. 12, 16, 20 EHIA20HB10 20 kw 3--Phase w/c.b. 16, 20 EHIA25HB10 25 kw 3--Phase w/c.b. 16, 20 KN = 1--phase T.B. = terminal block KB = 1--phase C.B. = circuit breaker HB = 3--phase SINGLE POINT WIRING KIT Heater size AK20SPA Single Point Wiring Kit (4--pole) kw AK30SPA Single Point Wiring Kit (6--pole) 25 kw OUTDOOR THERMOSTAT A002OTA 2--Stage ODTS Heater size 15 kw and above DOWNFLOW KIT A08DFB1 Downflow kit 08 A12DFB1 Downflow kit 12 A16DFB1 Downflow kit 16 A20DFB1 Downflow kit 20 International Comfort Products, LLC Lewisburg, Tennessee U.S.A
BLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES
BLOWER COILS 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Grooved copper tubing Lanced sine--wave aluminum fin Fully wettable
More informationBLOWER COILS COMMERCIAL
BLOWER COILS COMMERCIAL 2 THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Listed By Underwriters Laboratories Grooved copper tubing
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationDVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons
DVPTC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons Contents Air Handler Nomenclature...2 Heater Kit Nomenclature...2 Product Specifications...3
More informationCabinet Features Heavy-gauge, galvanizedsteel. powder-paint finish Full perimeter rail Sloped drain pan Easy to service
DG ommercial 7½- TO ½-TON THREE-PHASE PAKAGED GAS/ ELETRI UP TO. EER / 80% AUE ooling apacity: 88,000,000 BTU/h Heating apacity (Output): 68,000 BTU/h ontents Nomenclature... Product Specifications...
More informationAIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology
AIR CONDTIONERS XC16 ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology E N G I N E E R I N G D ATA Bulletin 210465 October 2009 Supersedes March 2009 SEER up to 17.20 2 to 5 Tons Cooling
More informationProduct Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.
Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09262 the environmentally sound refrigerant This product has been designed and manufactured
More informationProduct Data. (Unit shown with optional economizer.)
COOLING ONLY/ELECTRIC HEAT PACKAGED ROOFTOP UNIT 15 TO 27.5 NOMINAL TONS Product Data (Unit shown with optional economizer.) C09316 Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is it illegal to install a wet-niche luminaire face-up
More informationProduct Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)
38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons Product Data Carrier s air-cooled air conditioning split systems: S provide a logical solution for commercial needs S have
More informationVAV WITH ELECTRIC HEATER
VAV WITH ELECTRIC HEATER Electric Heater Electric heating coils are applied on VAV terminal units as terminal reheat devices. Electric heat coil capacity is rated in kilowatts (kw). Coils are available
More informationGerber M Series Site Requirements
Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick
More informationVIBRAPAC 3 AT A TIME INSTALLATION MANUAL F9801US OCTOBER 1999 US$250
VIBRAPAC 3 AT A TIME 466365F9801US OCTOBER 1999 US$250 World Headquarters 801 Johnson St. Alpena, Michigan, 49707 U.S.A. Phone (517) 354-4111 COMPANY NAME:... SERIAL NUMBER:... ASSEMBLY NUMBER:... WIRING
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationProduct Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS
Z / D 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons Product Data FEATURES / BENEFITS Z07-14 shown C09227 the environmentally sound refrigerant Carrier s air-cooled air
More information2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationVENTILATION AIR CONDITIONING AIR CLEANING HEATING
Heat Recovery Units VENTILATION AIR CONDITIONING AIR CLEANING HEATING Cross flow heat recovery units Applications New Designed for energy saving and indoor air quality control within ventilation systems.
More informationProduct Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.) C09248
Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 the environmentally sound refrigerant This product has been designed and manufactured
More informationStandard of Practice - Campus Electrical Distribution System
A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all
More informationDOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES
Guidelines effective March 5, 2007 NES is committed to providing safe, reliable electric service at a reasonable price for all of our customers. These guidelines offer direction for activities relating
More informationBulletin Working space about electrical equipment Rules 2-308, and Issued April 2010 Supersedes Bulletin 2-9-3
-9-4 Bulletin -9-4 Working space about electrical equipment Rules -308, -310 and -31 Issued April 010 Supersedes Bulletin -9-3 Scope (1) Minimum working space around electrical equipment () Questions and
More informationB. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationDIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...
DIVISION 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN Contents 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION 13 00 60 LIST OF FIGURES... 6 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN 1. General Requirements
More information2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment
ANSI/AHRI Standard 1230 with Addendum 2 2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment Approved by ANSI on 2 August 2010 ANSI/AHRI
More informationElectric Service Standards
V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are
More informationUL th Edition: The New Standard for the HVAC/R Industry
The New Standard for the HVAC/R Industry Intertek Testing Services 1809 10th Street Suite 400 Plano, TX 75074 www.intertek.com/hvac 1-800-WORLDLAB icenter@intertek.com Content Introduction 1 Critical Timing
More informationUNDERGROUND SERVICES SECONDARY
Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-
More informationFor the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).
II. 600 Volts, Nominal, or Less 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be provided and maintained about all electrical equipment to permit ready and safe operation
More informationFeatures SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S
Type List Terminal style Quick terminal Contact form Designation Features A general purpose Power Relay. Contact rating up to 12A 250VAC (). Epoxy sealed type and flux free. Quick connect terminal or PCB
More informationPre-installation Manual CONCEPT 301 D/401 D/501 D
Pre-installation Manual CONCEPT 301 D/401 D/501 D Pre-installation Manual CONCEPT 301 D/401 D/501 D Concept 301 D T11416 Edition BA, January 2015 This book has part No 10077155 0-2 This manual is published
More informationAir Conditioners. Technical Data. Pair application EEDEN RXS-J
Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................
More informationARC STUD WELDING SYSTEMS
ARC STUD WELDING SYSTEMS ARE complete stud welding systems which weld ARC studs using the ARC stud welding process. CONSIST OF the following items: An ARC stud welding power supply with built-in timer/control
More informationS9V2 Two Stage ECM Variable Speed
S9V2 Two Stage ECM Variable Speed S9V2 Direct Vent Table FUR-1-A Variable Speed, 2 Stage, Direct Vent, Upflow/Horizontal Left/Horizontal Right Condensing Gas Furnace (120/1/60)3 Unit In Output (Btuh) ICS1
More informationTelecommunication Spaces
Telecommunication Spaces October 19, 2016 Page 1 Revision History Telecommunication Spaces Standard Effective Date Email Version Contact Phone OIT-TS strevena@csustan.edu 1.0 Stan Trevena 209.667.3137
More informationTRANQUILITY WATER-TO-WATER SERIES
TRANQUILITY WATER-TO-WATER SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your
More informationPRG366GH 36-INCH GAS PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE
Also Available: PRL366GH - LP FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision simmering
More informationLarge University Central Chiller Plant Design Considerations
Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful
More informationThree-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier
of 5 Page Car SingleVario 06 Stack Parker 06 50 for vehicle up to 5.00 m = 6 long (50 for vehicle up to 5.0 m 7 long) Depending on location, design also as wind protection. Product Data CONFORMITY 06/06/G63
More information2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING
2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending
More informationFilter Media 452 sq. ft. (42 sq. m) Accu-Rated Airflow 900 cfm (425 L/sec.) Sound Level Approximately 77 dba at 5 ft. (1.5 m)
FILTAIR Capture 5 Issued July 2016 Index No. AY/3.5 Welding Safety and Health Quick Specs Industrial Applications Heavy equipment manufacturing Fabrication Maintenance and repair operations Processes Stick
More informationEFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,
TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.
More informationBULLETIN SUBJECT: GENERAL BULLETIN, 2015 SASK INTERPRETATIONS CORRECTIONS, AND ELECTRIC SERVICE REQUIREMENT CHANGES OR ADDITIONS
SaskPower Electrical Inspections BULLETIN 01-2017 February 15, 2017 TO: LICENSED ELECTRICAL CONTRACTORS ELECTRICAL CONSULTANTS AND ENGINEERS SUBJECT: GENERAL BULLETIN, 2015 SASK INTERPRETATIONS CORRECTIONS,
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More information1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.
PART 1: GENERAL 1.01 Section Includes A. Dual duct terminal units. B. Variable volume regulators. C. Integral damper motor operators. D. Integral controls. 1.02 Related Sections A. Section 23 00 00 Heating,
More informationInstallation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01
Installation plan Washer-extractor PW 6107 EL en - GB 10.11 M.-Nr. 09 270 450 / 01 M.-Nr. 09 270 450 / 01 2 Technical Datasheet Washer-extractor: Heating: PW 6107 Electric (EL) Legend: Solid circle
More informationTECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)
TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used
More informationCONTACT LIST DOORS IN THE PATH OF EGRESS TRAVEL SHALL MEET THE REQUIREMENTS OF ICC / ANSI A117.1 : SECTION MANEUVERING CLEARANCES AT DOORS
DOORS TO EXTERIOR HAVE CLOSURES & LATCHES AND MEET THE REQUIREMENTS OF ICC / ANSI A7. : SECTION 404.2.7 DOOR HARDWARE SECTION 404.2.8 CLOSING SPEED SECTION 404.2.9 DOOR OPENING FORCE SECTION 404.2.5 TRESHOLDS
More informationHotSwap MBP Maintenance Bypass
ENGLISH HotSwap MBP Maintenance Bypass MBP6K208 MBPK208 Installation and user manual Copyright 202 EATON All rights reserved. Service and suort: Call your local service representative SAFETY INSTRUCTIONS
More informationAUTOMATIC BALING PRESS MODEL: HRB-CENTURION 200HP; 13/9
Harris Equipment PROPOSAL SPECIFICATION: 20061122-121313 AUTOMATIC BALING PRESS MODEL: HRB-CENTURION 200HP; 13/9 GENERAL LAYOUT DRAWING: APPLICATION: 3A-13873 (LH/RH); 3A-13874 (LH/LH) 3A-13875 (RH/LH);
More informationSection 5 Roller Chain Drive Components
8981 00 269 08/14 TSplus Assembly Conveyors -1 Roller Chain Components Section Roller Chain Components TSplus roller chain drives provide the largest payload carrying capacity of the three conveying media
More informationSingle Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder
EN G IN EERI N G Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder Fundamentals of Capacitive Discharge Resistance Welding deliver repeatable welds even during line voltage
More informationThe Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999
CANADIAN ELECTRICAL CODE 1 The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999 Repealed by Chapter E-6.3 Reg 8 (effective June 24, 2003). Formerly Chapter E-6.3 Reg 6 (effective March
More informationInstallation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02
Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380
More informationImperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP
Service Manual Imperial Series Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP Contents of Service Manual 1. Safety Precautions ------------------------------------------------------------------
More informationEffective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.
Siemens, Model # SUAS877-PG (or Landis & Gyr # UAS877-PG) Eaton-Durham Model # UTRS223ACH Milbank Midwest Model # U980-O UTRS223AMEP These are some examples of the single meter sockets we require for underground
More informationROOF ICE MELT RIM SYSTEM
ROOF ICE MELT RIM SYSTEM This design guide provides the information necessary to help our design engineers design your Raychem Roof Ice Melt (RIM) system. For other applications or for design assistance,
More informationEngineering Data for Copper and Aluminum Conductor Electrical Cables
2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION
More information50KC Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613
Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS & ACCESSORIES...
More informationModel FDL 115 Safety drying chambers for limited quantities of solvent
Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and
More informationIECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST
IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST ENVELOPE REQUIREMENTS Project: Date: Instructions RECOMMENDED: List performance values, note exceptions that were applied, or provide other
More information2013 Title 24, Part 6 Residential HVAC April 11, Gina Rodda Gabel Associates, LLC
2013 Title 24, Part 6 Residential HVAC April 11, 2014 Gina Rodda Gabel Associates, LLC Course Goal Brief overview of MAJOR CHANGES in 2013 Title 24, Part 6 for Residential HVAC (new construction, additions
More informationMINIMUM SPECIFICATIONS
MINIMUM SPECIFICATIONS A) GREENHOUSE STRUCTURE: (EDUCATOR) 30 X 96 Galvanized Steel Frame Consisting of: A. Column Post: Allied 2 x 4 Rectangle 6 Spacing B. Bows: Allied 2 x 3 Rectangle 6 Spacing C. Trusses:
More informationB. Shop Drawings: For air terminal units. Include plans, elevations, sections, details, and attachments to other work.
SECTION 233600 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units. 2. Shutoff, single-duct air terminal units. 1.2 PERFORMANCE REQUIREMENTS A. Structural Performance:
More informationUnit Coolers SKB. 4 kw 30,5 kw.
Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...
More informationTable of Contents. Page Title
Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade
More informationUNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES
7.01 GENERAL UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES Also refer to Chapter 3 (Service Entrances), and Chapter 4 (Metering Installation). OPPD will install,
More informationCITY OF SOUTH GATE SCHEDULE OF FEES APPROVED
DESCRIPTION OF FEE - BUILDING & SAFETY PERMIT FEES - BUILDING $124 s.f. valuation PERMIT FEES - BUILDING ISSUANCE FEE $27 PERMIT FEES - BUILDING PERMIT TO RESTORE $46 PERMIT FEES - SPECIAL REVOLVING FUND
More informationPROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm
Fact Sheet PROflex* 60 Hz Reverse Osmosis Machines from 50 to 60 gpm Flexible Design PROflex has 0 base configurations using 8 to 7 elements that allows user to choose various pumps and membrane element
More informationProduct Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.
Product Catalog Variable Refrigerant Flow (VRF) System Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH/4TVR0072 0192 4TVH/4TVR0216 0528 Single Unit Modules Multi-Unit Modules January 2016 VRF-PRC008C-EN
More informationRoof & Gutter Ice/Snow Melting Design Guide
Roof & Gutter Ice/Snow Melting Design Guide Page 1 of 10 Roof & Gutter Ice/Snow Melting Design Guide CONTENTS Application Overview Page 2 STEP 1 Layout Page 4 STEP 2 Calculating Amount of Cable Page 5
More information2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical
ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel
More information3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package
3M Intelligent Return Plus and Sorter System SL Architect/Contractor's Package 3M, 2015. All rights reserved. 3M Intelligent Return Plus and Sorter System SL Architect/Contractor's Package, 78-8129-4937-4B
More informationSECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number
MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and
More informationGeothermal Comfort Systems
Frequently Asked Questions Q: How efficient are geothermal heat pump systems? A: Actual efficiencies will depend on a number of factors, but generally speaking a geothermal heat pump can be three to five
More informationCity of Roman Forest
City of Roman Forest Building Department Phone: 281-399-2660 Residential Construction & Land Development Introduction The City of Roman Forest has adopted the 2006 International Building Codes and Amendments,
More informationDesign and development of a residential gas-fired heat pump
Design and development of a residential gas-fired heat pump Edward A Vineyard a*, Ahmad Abu-Heiba a, Isaac Mahderekal b a Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN, 37831, USA
More informationELVORON LU/LA ELEVATOR
Creating An Accessible World ELVORON LU/LA ELEVATOR DESIGN AND PLANNING GUIDE www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site
More informationUnit Substation Transformer Construction Checklist (under 500 kva)
Unit Substation Transformer Checklist (under 500 kva) Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.
More information22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING
22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your home remains
More informationEnergy Savers: Air-Source Heat Pumps
1 of 5 4/25/2009 8:55 AM U.S. Department of Energy - Energy Efficiency and Renewable Energy Energy Savers Air-Source Heat Pumps An air-source heat pump can provide efficient heating and cooling for your
More information(Condensed from National Electric Code)
WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,
More informationProduct Application. Prestige Power Post in White Epoxy Coated Aluminium Finish
Product Application 83 Prestige Power Post in White Epoxy Coated Aluminium Finish 84 Floor Distribution Technical Floor Distribution Technical 85 Range Technical Data Raised Floor Systems Interact Underfloor
More informationBUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466
BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein
More informationCITY OF GRANDE PRAIRIE
Inspection Services CITY OF GRANDE PRAIRIE HOMEOWNER S PERMIITS AND WIRING GUIDE FOR ELECTRICAL INSTALLATIONS 2016 INDEX Page Applying for an Electrical Permit 3 Permit Application Requirements 3 Permit
More informationREQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS
REQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS Introduction An applicant applying for permanent electric service who opts to have the padmounted transformers installed inside his building
More informationINSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS
INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using
More informationYORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM
YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATORS Regardless of building type or rating system, today s building must be as energy
More informationFTW 175 Wireless Monitoring System Reference Manual Part Number
FTW 175 Wireless Monitoring System Reference Manual Part Number 7911751 SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 www.spx.com/en/flash-technology (615) 261-2000 Front Matter
More informationSECTION CHAIN-LINK FENCES AND GATES 02821/1
SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com VERSION Z MODELS 300500 SUMP PUMPS Your pump
More informationSECTION SLUDGE HOLDING TANK DECANTER PUMP
PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Sludge Holding Tank Decanter Pumping System in accordance with the
More informationExisting Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne
Existing Building Cx: Processes & Results A Cultural Journey Barry Abramson Senior Vice President Servidyne AIA Quality Assurance Learning Objectives 1. Define the key steps in the process of retrocommissioning
More informationAir Cooled Packaged Air Conditioning
Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated
More informationProduct Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.
Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems
More informationProduct Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with optional economizer.
Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationASHRAE 62.2: What s New in 2016
ASHRAE 62.2: What s New in 2016 Rick Karg 2016 Residential Energy Dynamics, LLC What We Will Talk About Overview of mechanics of 62.2-2016. Logic behind the Standard. Sizing local ventilation (exhaust-only).
More informationSite Preparation Guide. Stratasys J750 3D Printing System. DOC Rev. D1
Site Preparation Guide Stratasys J750 3D Printing System DOC-08015 Rev. D1 Copyright Copyright 2016 Stratasys Ltd. All rights reserved. This documentation contains proprietary information of Stratasys
More informationBasic Requirements for Residential Electrical Installations
Basic Requirements for Residential Electrical Installations Wayne County Building Department 428 West Liberty Street Wooster, Ohio 44691 Phone: 330-287-5525 Fax: 330-287-5649 This brochure is intended
More information15 kv EPR Insulated, Jacketed, URD Cable
15 kv EPR Insulated, Jacketed, URD Cable 1000 kcm Copper Conductor with Tape Shield Page 1 of 11 Table Of Contents 1 GENERAL... 3 2 STANDARDS... 3 3 APPROVED CABLE MANUFACTURERS... 3 4 REEL SPECIFICATIONS...
More information