1 10 Fan Coil Units
2 T31 10 version Dimensions, Weight, Water content C ,5 C 160, Feet optional extra COL CONNECTONS PCKGNG row coils Heating additional coil (1 row) Ø 1/" F Ø 1/" F T Ø 15 ext. Ø 15 ext. O S N R Z M H P H Dimensions (mm) Weight (kg) Water content (litres) C H M Rows +1 Weight with packaging Weight without packaging Rows +1 10, 0,9 N 70 O 50 P 10 R 110 S 65 T Z 1895
3 10 version Technical features units with row coil pipe units. The following standard rating conditions are used: COOLNG Entering air temperature + 7 C d.b C w.b. Water temperature + 7 C E.W.T. + 1 C L.W.T. 10.-T MX ir flow Cooling total emission Cooling sensible emission Heating Dp Cooling Dp Heating Fan Sound power W Lw d() 7,1 5, 9,05 7,5 6, ,31 6,0 10,65 9,8 8, ,63 7,5 1,51 1,7 10, ,5 8,3 13,68 1,7 11, ,3 8,9 1,85 16,7 13, Sound pressure (*) Lp d() HETNG Entering air temperature + C Entering water temperature + 50 C Water flow rate as for the cooling conditions units with 1 row additional coil pipe units. The following standard rating conditions are used: COOLNG Entering air temperature + 7 C d.b C w.b. Water temperature + 7 C E.W.T. + 1 C L.W.T. 10.-T MX ir flow Cooling total emission Cooling sensible emission Heating Dp Cooling Dp Heating Fan Sound power W Lw d() 7,1 5, 6,6 7,5 19, ,31 6,0 7,58 9,8, ,63 7,5 8,63 1,7 30, ,5 8,3 9,09 1,7 33, ,3 8,9 9,69 16,7 37, Sound pressure (*) Lp d() HETNG Entering air temperature + C Water temperature + 70 C E.W.T C L.W.T. --MX = Standard connected speeds. (*) = The sound pressure levels are 9 d() lower than the sound power levels and apply to the reverberant field of a 100 m 3 room and a reverberation time of 0.5 sec. Operation limits Highest water inlet temperature C Lowest water inlet temperature C for entering water temperatures below + 5 C, contact the technical department Highest working pressure (10 bars) Water flow limits () Rows +1 Lowest Highest Motor electrical data (max. absorption) 30/1 W 50Hz ,3
4 10 version Cooling emission of row coil Entering air temperature: 7 C R.H.: 50% WT: 7/1 C WT: 8/13 C WT: 10/15 C WT: 1/17 C 10. MX 100 1,11 11,6 10,37 8,95 7,67 8,86 8,18 7,8 6,38 5, ,0 16,8 1,5 11, 8,5 10,81 10,06 9,8 8,01 6,88 8,3 7,70 7,0 6,00 5, ,5 13,7 11,8 9,1 7,0 8,08 7,5 6,97 6,0 5, 7,9 6,73 6,15 5,3, , 8,1 7,1 5,5, 6,1 5,91 5,0,60 3,9 6,1 5,91 5,0,60 3, ,0 5,, 3,,5 Entering air temperature: 6 C R.H.: 50% WT: 7/1 C WT: 8/13 C WT: 10/15 C WT: 1/17 C 10. MX ,77 10,0 9,3 7,97 6,83 8,36 7,71 7,05 6,01 5, ,5 13,6 11,8 9,1 7,0 9,7 8,8 8,13 7,03 6,0 7,8 7,3 6,60 5,63, ,3 10,8 9, 7,3 5,6 6,97 6,3 5,76 5,01,33 6,97 6,3 5,69,8, ,1 6,1 5,1 3,9 3,1 5,85 5,0,93, 3,59 5,85 5,0,93, 3, ,1, 3,8,9, Entering air temperature: 5 C R.H.: 50% WT: 7/1 C WT: 8/13 C WT: 10/15 C WT: 1/17 C 10. MX 100 9,6 8,80 8,1 7,01 6,0 7,85 7, 6,6 5,6, ,3 10,9 9, 7,3 5,6 8,16 7,60 7,01 6,07 5, 7,3 6,75 6,17 5,5, , 8,3 7, 5,6,3 6,1 5,9 5,1,61 3,39 6,1 5,9 5,1,61 3, ,1 5,3,5 3,,6 5,8,88,6 3,80 3,5 5,8,88,6 3,80 3, ,3 3,7 3,, 1,8 Correction factors for different R.H. R.H. 8% 6% WT: Pc Ps Pc Ps 7/1 C 8/13 C 10/15 C 1/17 C 0,95 0,90 0,9 0,88 Legend WT = Water temperature Pc = Cooling total emission Ps = Cooling sensible emission = Emission = Water flow = Water pressure drop = Fan speed MX = High speed = Medium speed = Low speed = ir flow
5 10 version Heating emission of row coil Entering air temperature: C WT: 70/60 C WT: 60/50 C WT: 50/0 C WT: 50/5 C WT: 5/0 C 10. MX 100 5,37 3,37 1,30 18,07 15, ,1 13,9 11,8 8,8 6,6 19, 17,89 16,3 13,86 11, ,3 9,0 7,6 5,7,3 13,6 1,1 11,33 9,6 8, ,6,9,1 3,1,3 15,9 1,7 13,01 11,0 9, ,,9 17,8 13,3 10,0 1,55 11,56 10,5 8,95 7, ,0 1,7 1,5 9, 7,0 Heating emission of 1 row additional coil Entering air temperature: C 10 MX 100 WT: 80/70 C WT: 75/65 C WT: 70/60 C WT: 65/55 C WT: 60/50 C WT: 55/5 C 1,03 11,9 10,71 9,0 8, ,6 7,9 3,7 3,7 7,3 10,85 10,19 9,67 8,9 7, , 9,69 0,6 9,09 37,0 8,63 9, 7,58 3, 6, ,7 8,5 33,7 8,00 30,8 7,59,5 6,67 19,3 5, ,5 7,35 7,3 6,91,9 6,55 19,8 5,76 15,6 5, ,9 6,19 1, 5,81 19,6 5,5 15,6,85 1,3, ,0 16,1 1,7 11,7 9, Water pressure drop Dp row coil 1 row additional coil Dp Water flow () Water flow () The water pressure drop figures refer to a mean water temperature of 10 C; for different temperatures, multiply the pressure drop figures by the correction factors K. C K 0,9 0,90 0,86 0,8 0,78 0,7 0,70 The water pressure drop figures refer to a mean water temperature of 65 C; for different temperatures, multiply the pressure drop figures by the correction factors K. C K 1,1 1,08 1,0 0,96 0,90 5
6 ccessories for 10 P main coil 3 way valve Control valve kit: 3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. C D E Code alve Micrometric lockshield valve FTTED 9069H NOT FTTED 90690H 3, 3/ F 3,5 Dimensions ± 10 mm HERTH additional coil 3 way valve Control valve kit: 3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. C D Code alve Micrometric lockshield valve FTTED 90607H NOT FTTED H 15 1/ 1,6 15 1/ F Dimensions ± 10 mm HERTH way valve for main and additional coil Control valve kit: way valve, ON-OFF, with electric motor and mounting kit. C D E H Code Main dditional alve FTTED NOT FTTED FTTED NOT FTTED 90693H 90691H H H / 1,7 Dimensions ± 10 mm HERTH Dp - 0 3,5 1, Water 1 flow ()
7 ccessories for 10 Extension condensate collection tray to cover valve assembly S (for vertical units) SO (for horizontal units) Code Connection side LEFT RGHT Type SO-SX SO-DX Code SCR plastic condensate drain pipe with fast connection (allows correct condensate drain) Code 6060 PP feet Code For informations about electrical controls, please refer to the documentation of the Fan Coil Units. The descriptions and illustrations provided in this publication are not binding: we reserve the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. 7
8 10-11/10 Cod /11/10
Carisma CRS-ECM. High Pressure Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board
Carisma CRS-ECM igh Pressure Fan Coil Unit with EC rushless Electronic Motor and Inverter oard Range includes 3 air rates (from 3 to 14 m 3 /h) each equipped with 3 or 4 row coil and with the possibility
More informationELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor
Technical Bulletin BT16N008GB-04 ELFOSpace WALL Water terminal unit for indoor installation, wall-mounted CFW 00.0 021.0 RANGE DC Brushless Motor High standards of efficiency and low noise New design Electronic
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationMHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3
MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model
More informationMHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3
MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 18,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 18,000 BTUH Multiaqua Model
More informationMHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3
MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 12,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 12,000 BTUH Multiaqua Model
More informationRotary Vane Vacuum Pumps
Oil Lubricated Can withstand high level of inlet water vapor For saturated air (wet) service VRTL 5W Low Maintenance Air Cooled Design Single stage Integrated closed loop oil recirculation system Cheshire
More informationCOMPLIANT EUROPEAN STANDARD WITH THE NEW EN Heating / Air Conditioning Pulsar P.FE Radiant Panel ENVIRONMENTAL COMFORT
COMPLINT WITH THE NEW EUROPEN STNDRD EN 14037 Heating / ir Conditioning P.FE Radiant Panel Quality management systems ISO 9001 Cert. n 0545/5 ENVIRONMENTL COMFORT Heating ir Conditioning ENVIRONMENTL COMFORT
More informationCondensers & dry coolers ODIN. Excellent energy yield & sound characteristics
Condensers & dry coolers ODIN Excellent energy yield & sound characteristics O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................. 2 Eurovent.......................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-GV Outdoor Unit RX-GV TABLE OF CONTENTS RX-GV Features............................................................. 2 2 Specifications.......................................................
More informationNV series. Induction VAV air volume control terminals
NV series Induction VAV Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 overview / dimensions 4-5 Sound data NVOAOOB 6-7
More informationWater terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw
Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6
More informationWater terminals from 360 to 1598 m 3 /h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw
Water terminals from 360 to 1598 m 3 /h SysQuare Chilled water cassettes from 1.4 to 9.6 kw from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6
More informationWater terminals from 360 to 1598 m3/h. from 1.4 to 9.6 kw. SysQuare. Chilled water cassettes. from 1.1 to 14.0 kw
Water terminals from 360 to 1598 m3/h from 1.4 to 9.6 kw SysQuare Chilled water cassettes from 1.1 to 14.0 kw SysQuare The best way to combine low noise and energy savings ErP 2018 OFFICES HOSPITAL 6 sizes
More informationNon-Ducted Indoor Compressor Type DC Inverter Driven Rotary Rated Cooling Capacity BTUH RLA 10.8
Submittal Data: Multi-Room Ductless heat-pump systems 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationi-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationF64G - Olympian Plus Plug-In System General purpose filter
> > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:
More informationVENTILATION AIR CONDITIONING AIR CLEANING HEATING
Heat Recovery Units VENTILATION AIR CONDITIONING AIR CLEANING HEATING Cross flow heat recovery units Applications New Designed for energy saving and indoor air quality control within ventilation systems.
More informationGitie. A CHOICE SMARTER than solar systems. Trivalent integrated outdoor package
ing l o.. Air is enough. ction and co du ro for heating, domestic hot water p A CHOICE SMARTER than solar systems Gitie Trivalent integrated outdoor package with absorption heat pump powered by natural
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0
More informationWETROOM LINEAR FLOOR FORMERS
WETROOM LINEAR FLOOR FORMERS Level Access 30mm Floor Formers Centre Waste Q4-23165 Linear Floor Former 900x900 372 Q4-23166 Linear Floor Former 1200x1200 498 Linear 300 centre drain Level Access 30mm Floor
More informationFilter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with pressure gauge ATEX certified
Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with gauge ATEX certified 00119372 ATEX Maintenance Unit Parts Regulator type Regulator function Lock type Pressure supply
More informationWater Source Heat Pump Unit Product Line WSHP
WSHP CHPW Slope or Flat Top Console Units HHPW Horizontal Units VCHPW Vertical Closet Units VSHPW Vertical Stack Units Water Source Heat Pump Unit Product Line Contents Overview 3 Slope or Flat Top 4 Console
More informationPerformance Rated for Water Loop Applications Cooling capacities : entering air conditions of 80.6ºF db / 66.2º F wb, 86ºF entering water temperature
Performance Rated for Water Loop Applications Cooling capacities : entering air conditions of 80.6ºF db / 66.2º F wb, 86ºF entering water temperature Heating capacities : entering air conditions of 68ºF
More information2-Pipe fan coil terminal units were selected as the parallel system to handle the remaining sensible cooling load.
Redesign Introduction This report is an in depth analysis of the mechanical systems of the Outreach Innovation Building located in University Park, PA and the impact these changes had on other systems
More informationOutdoor air treatment units
Outdoor air treatment units A +++ A ++ A + A B C D ErP Fresh Air Unit The FAU series of outdoor air treatment units, with Lossnay enthalpic energy recovery module, direct expansion coil and integrated
More informationUFR+L FILTER REGULATOR + LUBRICATOR
FEATURES The UFR+L filter regulator + lubricator is intended for the treatment of compressed air or compressed gas. Its function is that of supplying filtered, lubricated air at the desired pressure for
More informationInstallation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01
Installation plan Washer-extractor PW 6107 EL en - GB 10.11 M.-Nr. 09 270 450 / 01 M.-Nr. 09 270 450 / 01 2 Technical Datasheet Washer-extractor: Heating: PW 6107 Electric (EL) Legend: Solid circle
More informationMIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump
MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump
More informationCI/SfB (57.7) 1st edition
CI/SfB (57.7) 1st edition Vent-Axia Sentinel Multivent Wholehouse Mechanical Extract Ventilation System Ventilation Lo-Carbon Energy saving solutions Sentinel Multivent continuous mechanical extract ventilation,
More informationCombustion Laboratory Unit C492
Combustion Laboratory Unit C492 Figure 1: C492 Unit Purpose built Combustion Chamber, with Instrumentation. Designed for Supervised Student Operation. Oil or Gas Burners Available. Changes to Burner Settings
More informationPT Mount. Multi-purpose Application & Economical. Multi-purpose Application at Low Cost. Round Type Vibration-proof Rubber. Example for Installation
Round Type Vibration-proof Rubber PT Mount Multi-purpose Application & Economical Wide Load Range Multi-purpose Application at Low Cost Respond widely, if Summarize power A, B, C, Company TOZEN Reasonable!
More informationMulti-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1CO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date
Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation
More informationInstallation Plan. Washer-extractor PW 6088 EL LP. en - AU M.-Nr
Installation Plan Washer-extractor PW 6088 EL LP en - AU 14.14 M.-Nr. 09 923 540 Australia: Miele Australia Pty. Ltd. 1 Gilbert Park Drive KNOXFIELD Victoria 3180 Tel. +61 3 97647-100 Fax +61 3 97647-129
More informationAir Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15
ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15 ir Cooled Scroll Chiller ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum
More informationMulti-Room Ductless heat-pump systems Submittal Data: MULTI24HP230V1CO 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date
Multi-Room Ductless heat-pump systems Submittal Data: 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation
More informationCFFWA-XX-1-U. Rev. 1.2
CFFWA-XX-1-U Rev. 1.2 CFFWA Universal Mount Fan Coils 12,000-60,000 BTUH -------------------------------------- CAUTION -------------------------------------- Care must be taken when handling sheet metal.
More informationLUBRICATION PUMP Z2 CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated
More informationALTERNATOR. LSA 36 - single-phase to 11.5 kva
3692 en - 2009.07 / f ALTERNATOR LSA 36 - single-phase - 3.5 to 11.5 kva LSA 36 ALTERNATOR Developed using special modelling software to give optimised electrical performance Designed to supply power to
More informationHITACHI Modular Chiller Solutions
Cooling Capacity 95kW - 1920kW Heating Capacity 92kW - 2384kW HITACHI Modular Chiller Solutions Giving you complete control The benefits of our unique modular design Projects change and develop over time.
More informationFlexdip CYH112. Technical Information. Holder system for water and wastewater assemblies
Technical Information Flexdip CYH112 Holder system for water and wastewater assemblies pplication Water treatment Wastewater treatment Plant design CYH112 is a modular holder system for sensors and assemblies
More informationUnit Coolers SKB. 4 kw 30,5 kw.
Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...
More informationCombustion Laboratory Unit C492
Combustion Laboratory Unit C492 Figure 1: C492 Unit with Optional C492A fitted Purpose built Combustion Chamber, with Instrumentation Designed for Supervised Student Operation Oil or Gas Burners Available
More informationYORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE
YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE Contents YORK Passive Chilled Beams 3 CB-PBE-YK / CB-PBR-YK Performance Data 5 CB-PBE-YK Dimensions 7 CB-PBR-YK Dimensions 8 Specifications 9 2 YORK Passive
More informationFSFCA (Ductless Direct Expansion Fan Coil) Rev. 1.1
FSFCA (Ductless Direct Expansion Fan Coil) Rev. 1.1 -------------------------------------- CAUTION -------------------------------------- Care must be taken when handling sheet metal. Sheet metal parts
More informationSplit. Air Conditioning Technical Data RXM-M9
Split Air Conditioning Technical Data RXM-M9 TABLE OF CONTENTS RXM-M9 1 Features............................................................. 2 2 Specifications.......................................................
More informationGAUTENG DEPARTMENT OF INFRASTRUCTURE DEVELOPMENT
GAUTENG DEPARTMENT OF INFRASTRUCTURE DEVELOPMENT BUILDING ASSESSMENT REPORT HVAC FOR ABSA Building OCTOBER 2014 Report for Gauteng Department of Infrastructure Development HVAC Services Preliminary Report:
More informationECOLOGICAL EVAPORATIVE COOLERS. 16,000 m 3 /h
F EVAPORATIVE COOLING Specialist Distributor: Adremit Limited, 5A Commercial Courtyard Settle, North Yorkshire. BD24 9RH. Tel. 01729 824108 www.puravent.co.uk info@adremit.co.uk F EVAPORATIVE COOLING Ne
More informationINTRODUCTION SPECIMEN DESCRIPTION
INTRODUCTION SPECIMEN DESCRIPTION Airborne sound transmission measurements were performed on a wall assembly with a single layer of the product identified by the client as QuietRock QR-530 Serenity on
More informationA EN ROUND STORAGE SILO. Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL. ARSKAMETALLI LTD
A70-1001-EN-201805 ROUND STORAGE SILO Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL ARSKAMETALLI LTD www.arskametalli.fi CONTENTS Introduction Delivery information EU Declaration of Conformity
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 11 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible
More informationUnloading Valve Series R4U
Characteristics Series RU Subplate mounted unloading valves series RU are used to unload a circuit at low pressure. The mechanically adjustable pressure signal to unload the main stage has to be applied
More informationRL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL
The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationSection 13 Lift-Position Units
BOSCH BOSCH HN08-0 Section HP2 Units () are used at workstations when workpiece pallets have to be accurately positioned. Lift-position units lift the workpiece pallet from the conveying media so that
More informationGas Turbine Inlet Air Cooling System
Gas Turbine Inlet Air Cooling System Presented by Bob Omidvar Heavy Duty GT - Effects of Ambient Temp 110% 105% 100% 95% 90% 85% 80% 75% 0 5 10 15 20 25 30 35 40 45 GT Inlet Temp (deg C) Heat rate kj/kwh
More informationTechnical Assignment 2 Building and Plant Energy Analysis
Technical Assignment 2 Building and Plant Energy Analysis Des Places Residence Hall Duquesne University Pittsburgh, PA Peter Edwards Advisor: James Freihaut October 4, 2010 Table of Contents Executive
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 6 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1600 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationEcophon Focus Ds. System range. Size, mm 600x x x x x x x600 T24 Thickness (THK)
Ecophon Focus Ds For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and syetrical edge
More informationUtilities Infrastructure Cooling Distribution. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc.
Utilities Infrastructure Cooling Distribution APPA Institute for Facilities Management Dallas Jan 2017 Bill Nelson PE 1 Purpose of Today s Presentation To provide a broad understanding of Chilled water
More informationi-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationHeating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3
Heating Technical Data Daikin Altherma hybrid heat pump EEDEN14-729 EVLQ-CV3 Outdoor Unit EVLQ-CV3 TABLE OF CONTENTS EVLQ-CV3 1 Features............................................................. 2
More informationFXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2
- C 1 Product Detail Engineering Data Models... C2 Structural Support Models... C6 Engineering Specifications... C8 - C 2 Engineering Data Models REMARK: Do not use for construction. Refer to factory certified
More informationBosch 4000S Internal Room-sealed continuous flow water heater and flue components
Bosch 4000S Internal Room-sealed continuous flow water heater and flue components Australian Models The Bosch 4000S Internal offers: 3 6 Star efficiency 3 Room sealed appliance 3 Inbuilt temperature controller
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1400 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationENGINEERING INFORMATION Hot water and steam service
ENGINEERING INFORMTION Hot water and steam service What is steam? Like other substances, water can exist in the form of a solid, when we call it ice; as a liquid when we call it water or as a gas when
More informationAir Conditioners 4AC13
PRODUCT SPECIFICATIONS R-40A Refrigerant 3 SEER.5 to 5 Tons High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity Top discharge directs hot air away
More informationCustom Systems Built to Exacting Client Specification
Custom Systems Built to Exacting Client Specification Laboratory Reactor Systems Parr Instrument Company is pleased to work with customers in the design and assembly of complete laboratory or pilot plant
More informationTOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available
TECHNICAL SUBMITTAL TR400018.r2 TOTEM Cogeneration (CHP) Range Highest total efficiency with modulating output and lowest NO X emissions available PRACTICAL, EFFICIENT & SUSTAINABLE BUILDING SERVICES SOLUTIONS
More informationDAT Commercial ELECTRIC AIR HANDLERS FOR 7½ & 10-TON SPLIT SYSTEMS
DAT Commercial ELECTRIC AIR HANDLERS F 7½ & 0-TON SPLIT SYSTEMS Contents Nomenclature... Product Specifications... Airflow Data... Heating Kit Data...6 Dimensions...7 Wiring Diagrams...8 Standard Features
More information01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR)
01 Introduction TARGET POSITION FEATRE Multi Domestic EHS Mono/Split Low Temperature - Domestic, 50 water EHS High Temperature - Domestic, 80 water All-in-One More Efficient Free of Charge 50 or 80 Water
More informationPLASTIC MATERIALS COLOURS. Plastic colour code. Steel colour. TRESTON Industrial Furniture TRESTON ESD products
STORAGE SYSTEMS WELL CONSIDERED, EFFICIENT SMALL PARTS STORAGE Good storage planning requires the combination of many elements. Treston offer a flexible and first class range of storage solutions to build
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 3 Project Name: Av. Cabildo 3067, 4 piso 02/13/2011 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1500 HEATING DATA AT DES HTG COOLING OA DB / WB 34.9 C / 23.8
More informationSection 12 Tandem Lift-transfer Units and VT2
-1 Section EQ2 Units (electrical transverse conveyors) are used to move workpiece pallets horizontally from one conveyor section to a second adjacent conveyor section. All EQ2 units are complete modules
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 8 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationResponsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
Air Conditioners Technical Data Technical Data O u t d o o r u n i t - P a i r a p p l i c a t i o n T E C H N I C A L DATA - O U T D O O R U N I T - PA I R A P P L I C AT I O N O u t d o o r u n i t -
More informationAir Conditioning. Technical Data EEDEN RXS-L
Air Conditioning Technical Data EEDEN15-100 RXS-L TABLE OF CONTENTS RXS-L 1 Features............................................................. 2 2 Specifications.......................................................
More informationProduct catalogue A25. Absorption Cooling Systems
Product catalogue A25 Absorption Cooling Systems COOLING POWERED BY NATURE FLEXIBLE DESIGN Purix cooling and air conditioning systems help you building a green tomorrow without compromising the basic needs
More informationFeatures. Standard specifications. Product name Model Measurement method
Organic Pollution Monitor OPM-630 This instrument consists of an organic pollution monitor that employs ultraviolet absorptiometry; it is an automatic water quality analyzer that uses a dual-wavelength
More informationProduct Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS
Z / D 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons Product Data FEATURES / BENEFITS Z07-14 shown C09227 the environmentally sound refrigerant Carrier s air-cooled air
More informationAtlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)
Atlas Copco Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-37 kw/10-50 hp)! " $ $ % $ $ & ' ' & & ( ' ' & & Extreme savings No idling time Silent operation Small footprint The new revolutionary
More informationMulti Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO
More informationMulti Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)
Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems
More informationAUTOCLAVE For Structure Repair and Fabrication
AUTOCLAVE For Structure Repair and Fabrication INTRODUCTION 1 INTRODUCTION We design and deliver autoclaves for the aerospace industry, for workshop and repair workshop and training schools Our ANICLAVE
More informationPRODUCT BROCHURE. Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : smartemp.com
PRODUCT BROCHURE Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : 07 smartemp.com DESCRIPTION The SMARTEMP Linear Multistream Ceiling Diffuser, type LMC-AD (figure ), is a multi-nozzle linear slot diffuser
More informationImportant Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA
Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure
More informationThermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationHDG Turbotec. HDG Log wood boilers. Comfortable and safe. 340-litre fuel chamber. Log wood sizes up to 1-metre long
HDG Log wood boilers HDG Turbotec Fuels: Log wood up to 1 metre logs Rough chips Capacity: 50 kw and 60 kw Comfortable and safe 340-litre fuel chamber Log wood sizes up to 1-metre long Highly effective
More informationModulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING.
Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationProduct Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.
Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems
More informationImportant Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA
Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure
More informationFOKOLUS TRADIZIONE TECNOLOGICA
FOKOLUS TRADIZIONE TECNOLOGICA FOKOLUS MODEL Nominal heat output min/max kw Wood storage kg Autonomy hrs FOKOLUS 20 15 20 60 5-7 FOKOLUS 0 2 0 70 5-7 FOKOLUS 40 1 8 90 5-7 The force of steel, the heating
More informationVentum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler.
Ventum Series The new Generation Wood Gasification Boilers Europe s Fastest Selling Wood Gasification Boiler. The New Generation Ventum Series leaps forward in gasification technology making them the fastest
More informationindoor air quality and energy saving TECHNICAL DATA JD/JD ENTHALPIC HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS
indoor air quality and energy saving TECHNICAL DATA JD/JD ENTHALPIC HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS JD Remotable high efficiency heat recovery module without fans. To be interfaced
More informationAir Conditioners. Technical Data. Pair application EEDEN RXS-J
Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................
More informationBosch OptiFlow Professional Internal
Bosch OptiFlow Professional Internal Room-sealed continuous flow water heater and flue components. The OptiFlow Professional Internal offers: 3 6 Star efficiency 3 Room sealed appliance 3 Inbuilt temperature
More informationFW SERIES. Friction welding machine SH-FW30/45/60 SHENG HUI. .Fully automated production line: -Increase production -Reduce manpower
FW SERIES Friction welding machine SHENG HUI SH-FW30/45/60.Fully automated production line: -Increase production -Reduce manpower.after welding, the strength is higher than that of the base metal, and
More informationGas purification systems for the highest level of purity
Gas purification systems for the highest level of purity High purity gases are used in many areas of industry and laboratories, for example, for analytical purposes. In some cases however, certain impurities
More informationRL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL
The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More information.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.
Issued 2005/05/16 Section 15641 Cooling Towers Induced Draft Crossflow Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationFloat valves Types SV 4, SV 5 and SV 6
Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia
More information