2015 INSPECTION REPORT FLY ASH DAM and BOTTOM ASH POND COMPLEX JOHN AMOS PLANT ST. ALBANS, WEST VIRGINIA. June 2015
|
|
- Esmond Lloyd
- 5 years ago
- Views:
Transcription
1 2015 INSPECTION REPORT FLY ASH DAM and BOTTOM ASH POND COMPLEX JOHN AMOS PLANT ST. ALBANS, WEST VIRGINIA June 2015 PREPARED BY GEOTECHNICAL ENGINEERING AEP SERVICE CORPORATION 1 RIVERSIDE PLAZA COLUMBUS, OHIO
2
3
4 2015 INSPECTION REPORT REV 1 BOTTOM ASH COMPLEX JOHN AMOS PLANT ST. ALBANS, WV TABLE OF CONTENT 1 INTRODUCTION SUMMARY OF VISUAL OBSERVATIONS GENERAL BOTTOM ASH POND COMPLEX POND COMPLEX CAPACITY AND DEPTH DATA ASSESSMENT OF INSTRUMENTATION DATA CONCLUSIONS AND RECOMMENDATIONS RECOMMENDATIONS THAT REQUIRE ATTENTION BEYOND REGULAR MAINTENANCE ACTIVITIES RECOMMENDATIONS REGARDING ROUTINE MAINTENANCE ITEMS... 5 Appendix A Inspection Photos Appendix B Figures NOTE: REVISION 1 SUPPLEMENTAL DATA ADDED ON MAY 10 TH, i
5 1 INTRODUCTION AEPSC Civil Engineering administers AEPSC s (American Electric Power Service Corporation) Dam Inspection and Maintenance Program (DIMP). As part of DIMP, staff from the Geotechnical Engineering Section conducts dike and dam inspections annually. This report presents a summary of the inspection and assessment of the condition of the ash disposal facilities at the John Amos plant. The 2015 dam and dike inspection at the Amos fly ash dam and the bottom ash complex was conducted by Mr. J.T. Massey-Norton on June 4 th, Mr. Rich Fuller served as the project facility contact and was present during the inspection. Weather conditions were overcast with a mixture of rain and snow, with temperatures ranging from a low of 65 F to a high of 75 F. There was intermittent precipitation on the proceeding day of inspection and 0.3 accumulative rainfall during the seven day period prior to the inspection. The Bottom Ash Complex consists of Bottom Ash Pond 1A (BAP-1A), Bottom Ash Pond 1B (BAP-1B), Reclaim Water pond (RCWP) Area 3and the Treatment pond (TP). The Main Perimeter Dike is located on three sides of the impoundment and grades into native ground along the southern boundary. The BAP-1B pond is bounded on the west by the filled former sedimentation pond and on the east by the BAP-1A. A splitter dike separates the BAP-1A and BAP-1B and the Reclaim Water pond. Figure 1 (aerial image plan view) illustrates the bottom ash pond complex. 2 SUMMARY OF VISUAL OBSERVATIONS 2.1 GENERAL This summary of the visual observations uses terms to describe the general appearance or condition of an observed item, activity or structure. The meaning of these terms is as follows: Good: A condition or activity that is generally better or slightly better than what is minimally expected or anticipated from a design or maintenance point of view.
6 Fair or Satisfactory: A condition or activity that generally meets what is minimally expected or anticipated from a design or maintenance point of view. Poor: A condition or activity that is generally below what is minimally expected or anticipated from a design or maintenance point of view. Minor: A reference to an observed item (e.g., erosion, seepage, vegetation, etc.) where the current maintenance condition is below what is normal or desired, but which is not currently causing concern from a structure safety or stability point of view. Significant: A reference to an observed item (e.g. erosion, seepage, vegetation, etc.) where the current maintenance program has neglected to improve the condition. Usually, conditions that have been previously identified in the previous inspections, but have not been corrected. Excessive: A reference to an observed item (e.g., erosion, seepage, vegetation, etc.) where the current maintenance condition is above or worse than what is normal or desired, and which may have affected the ability of the observer to properly evaluate the structure or particular area being observed or which may be a concern from a structure safety or stability point of view. 2.2 BOTTOM ASH POND COMPLEX The visual inspection indicated that the Bottom Ash Pond is classified as begin in good condition and is documented with the following visual observation of key features that pertain to dam safety. 1. The crest of the main perimeter dike was observed to be in good condition. No significant settlement, misalignment, erosion, or seepage could be observed on the crest or the slopes of the main perimeter dike (Photos 1, 2, 3). 2
7 2. A riprap revetment had been placed on the downstream toe of the main perimeter dike at the Reclaim and Treatment ponds to control erosion due to minor seepage along this area, reported in the previous inspection (Photo4). Minor seepage (approximate area 2ft x 5ft) discharging less than 0.1gpm was observed near the toe of the riprap area. 3. The inboard slope of the main perimeter dike exhibited a good vegetative cover. There were no visual signs of misalignment, settlement, sloughing, erosion, or bulging that would indicate any instability within the dike (Photo 5). 4. No erosion or seepage was noted along the pipe that extends out from outboard slope of the Main Perimeter dike at the Reclaim pond (Photo 6). A sounding test performed in 2010 on the accessible portion of the pipe did not reveal any change in the thickness of the wall thickness that would be an indication of internal corrosion of the pipe. This pipe was permanently abandoned by welding a steel plate at the discharge end of the pipe. 5. The vegetative cover on the inboard slope was also controlled by timely mowing. Drains (4 inch diameter HDPE) from the block wall were unobstructed and no erosion was noted downstream (Photo 7). 6. No settlement, misalignment or other defects were observed for the 2 emergency spillways (Photos 8). The inlet and outlet to both emergency pipes were observed to be in good condition (Photos 9 and 10). 7. The primary decant structure (outfall 003) was observed to be in excellent condition and a trash rack has been added to the structure (Photos 11). No concrete spalling or other defects were observed at the upstream decant structure or the downstream headwall where the effluent discharges into the Kanawha River. Flow from the pond is discharged thru the submerged diffuser. (Photos 12 and 13). Photo 30 also shows the discharge at the headwall from the storm water pond The staff gage in the Reclaim Pond measures the depth of the water in the pond but does not show the water elevation with respect to the sea level (Photo 14). 3
8 2.3 POND COMPLEX CAPACITY AND DEPTH DATA Based on the previous measurements and estimates and operational variation in the pond system, the capacity and volume estimates for the bottom ash ponds are provided below: Maximum Minimum Present* Pond Media Depth/Elevation ( feet) Water NA/NA NA/NA 6/580 Bottom Ash 1A Solid NA/NA** NA/ NA 14/574 Water NA / NA NA / NA 5/581 Bottom Ash 1B Solid NA / NA** NA / NA 16/576 Capacity (acre-feet) Pond Water Solid Total Bottom Ash 1A Bottom Ash 1B NA Not Available *Date of measurement May 6 th, 2015 ** Assumes base of impoundment to be at an elevation of 560 ft. based on design drawings. 3 ASSESSMENT OF INSTRUMENTATION DATA In 2005 four piezometers were installed in the main perimeter dike, three on the crest and one at the toe. Currently, only the crest piezometers are monitored as a part of the inspection program. The piezometric water levels have been relatively constant with no unusual fluctuations (Figure 2). The March15th, 2015 static water level measurements reflect a sudden spring snowmelt which increased Kanawha River stages with a corresponding increase in piezometric levels. 4 CONCLUSIONS AND RECOMMENDATIONS Visual inspection of the bottom ash pond performed on June 4 th, 2015 and a review of the instrumentation data along with the plant inspection reports did not reveal any adverse or significant condition that would raise concerns on the stability and safety of the facilities. Routine inspections, monitoring, and maintenance by plant personnel should continue. A site 4
9 specific summary of conclusions and recommendations of the visual inspection is presented in the following sections. 4.1 RECOMMENDATIONS THAT REQUIRE ATTENTION BEYOND REGULAR MAINTENANCE ACTIVITIES 1. The plant should install easily readable staff gages in all the ponds that are a part of the bottom ash disposal facility. Pond stage levels should be monitored and recorded during the regular inspections. 2. The pond water level elevations along the main perimeter dike is a key element that is used in conjunction with the piezometric data in interpreting the phreatic surface through the dike. It is recommended that the piezometer that has been installed at the toe of the embankment should also be monitored. This location may require a small walk way to be installed over the rip rap to access the piezometer. 4.2 RECOMMENDATIONS REGARDING ROUTINE MAINTENANCE ITEMS 1. Plant personnel should continue to perform maintenance as currently scheduled. 2. Plant personnel should perform monthly measurements of the four piezometers. 3. Plant personnel should implement and document weekly inspections of the bottom ash perimeter dike. In general, routine inspections, monitoring, and maintenance by plant personnel should continue. AEPSC Geotechnical Engineering Section will continue to inspect the facilities on an annual basis. If you have any questions with regard to this report, please contact J.T. Massey-Norton at (audinet ) or Gary F. Zych (audinet ). 5
10 APPENDIX A INSPECTION PHOTOS 6
11 Photo 1. Photo of the perimeter dike. No cracks, sloughing, bulges, erosion or other defects were observed. Photo 2. Photo of the exterior embankment along the Reclaim Pond showing established vegetation. No erosion, bulges or other signs of slope instability were observed.
12 Photo 3. Photo of the perimeter dike along the bottom ash pond 1A. Vegetation is well established and controlled. Photo 4. Typical view of rip rap along the outboard toe of the reclaim pond. View also shows the backwater area of Bills Creek. Minor seepage along the toe of the rip rap area was observed.
13 Photo 5. Typical view of the inboard slope and block wall. Photo 6. Typical view of the abandoned steel pipe along the outboard slope of the reclaim pond. A steel plate is welded to the end of the pipe.
14 Photo 7. Typical view of the outboard slope and 4 inch diameter HDPE drain pipe. Photo 8. Photo of emergency spillway pipe from bottom ash pond 1B.
15 Photo 9. Photo of emergency spillway pipe headwall from bottom ash pond 1B. Photo 10. View of the (downstream outlet) showing the addition of an animal guard / trash rack for the 36 inch diameter HDPE emergency spillway pipe.
16 Photo 11. View of the primary decant structure (upstream inlet) showing the unobstructed flow through the trash rack with effluent discharge into the elliptical 24 x 38 concrete pipe. Photo 12. View of the primary outfall structure (#003) showing the 6 inch diameter vent pipe.
17 Photo 13. View of the primary outfall structure (#003) showing the transition from the 24 x 38 concrete elliptical pipe to the 36 inch diameter steel pipe. The flange connection from the steel pipe to the 36 inch diameter HDPE is also partially exposed and showed no indication of leakage. The 36 diameter pipe conveys the effluent discharged from the bottom ash pond to 6 diffuser ports submerged along the bottom of the Kanawha River. Photo 14 Typical view of the reclaim pond showing the pond s staff gage. The numeric readings on the staff gage indicate a depth of water within the pond as opposed to a water level elevation.
18 APPENDIX B FIGURES 7
19 1
20 Water Level (ft) Figure 2 Amos Plant Bottom Ash Pond Piezometers B -1 B-3 B /10/06 02/22/08 07/06/09 11/18/10 04/01/12 08/14/13 12/27/14 05/10/16 Date
AMERICAN ELECTRIC POWER (SWEPCO)
2016 DAM & DIKE INSPECTION REPORT ASH PONDS GERS-16-163 WELSH POWER PLANT AMERICAN ELECTRIC POWER (SWEPCO) CASON, TEXAS NATIONAL INVENTORY NO. TX4357 PREPARED BY GEOTECHNICAL ENGINEERING AEP SERVICE CORPORATION
More information2016 ANNUAL DAM AND DIKE INSPECTION REPORT. Bottom Ash Ponds. Rockport Plant Spencer County, Indiana. December 6 th, 2016
2016 ANNUAL DAM AND DIKE INSPECTION REPORT Bottom Ash Ponds Rockport Plant Spencer County, Indiana December 6 th, 2016 Prepared for: Indiana Michigan Power Company Rockport Plant 2791 North US 231 Rockport,
More informationAMERICAN ELECTRIC POWER (SWEPCO)
2015 DAM & DIKE INSPECTION REPORT ASH PONDS GERS-15-034 WELSH POWER PLANT AMERICAN ELECTRIC POWER (SWEPCO) CASON, TEXAS NATIONAL INVENTORY NO. TX4357 PREPARED BY GEOTECHNICAL ENGINEERING AEP SERVICE CORPORATION
More information2017 Annual Dam and Dike Inspection Report
2017 Annual Dam and Dike Inspection Report Bottom Ash Pond Complex Mitchell Plant Wheeling Power Company & Kentucky Power Company Marshall County, West Virginia October 20, 2017 Prepared by: American Electric
More information2016 Annual Dam and Dike Inspection Report
2016 Annual Dam and Dike Inspection Report Fly Ash Pond John E. Amos Plant Appalachian Power Co. Putnam County, West Virginia November, 2016 Prepared for: Appalachian Power Co. 1530 Winfield Rd Winfield,
More information2018 Annual Dam and Dike Inspection Report
218 Annual Dam and Dike Inspection Report Bottom Ash Pond Northeastern 3&4 Plant Public Service Company of Oklahoma Oologah, Oklahoma September 218 Prepared for: Public Service Company of Oklahoma Northeastern
More information2016 DAM AND DIKE INSPECTION REPORT CCR PONDS COMPLEX
2016 DAM AND DIKE INSPECTION REPORT CCR PONDS COMPLEX GERS-16-168 OKLAUNION POWER STATION VERNON, TEXAS PREPARED BY AEP SERVICE CORPORATION CIVIL ENGINEERING DIVISION GEOTECHNICAL ENGINEERING SECTION 1
More information2017 ANNUAL DAM AND DIKE INSPECTION REPORT
2017 ANNUAL DAM AND DIKE INSPECTION REPORT ASH PONDS WELSH POWER PLANT CASON, TEXAS November, 2017 Prepared by: American Electric Power Service Corporation 1 Riverside Plaza Columbus, OH 43215 GERS-17-067
More information2017 ANNUAL DAM AND DIKE INSPECTION REPORT
2017 ANNUAL DAM AND DIKE INSPECTION REPORT CCR PONDS COMPLEX OKLAUNION POWER STATION VERNON, TEXAS November, 2017 Prepared by: American Electric Power Service Corporation 1 Riverside Plaza Columbus, OH
More information2015 LANDFILL INSPECTION REPORT CARDINAL PLANT BRILLIANT, OHIO
2015 LANDFILL INSPECTION REPORT GERS-15-021 CARDINAL PLANT BRILLIANT, OHIO PREPARED BY GEOTECHNICAL ENGINEERING AEP SERVICE CORPORATION 1 RIVERSIDE PLAZA COLUMBUS, OHIO Cardinal Plant Landfill Inspection
More information2016 LANDFILL INSPECTION REPORT CARDINAL PLANT BRILLIANT, OHIO
2016 LANDFILL INSPECTION REPORT GERS-16-004 CARDINAL PLANT BRILLIANT, OHIO PREPARED BY GEOTECHNICAL ENGINEERING AEP SERVICE CORPORATION 1 RIVERSIDE PLAZA COLUMBUS, OHIO Cardinal Plant Landfill Inspection
More informationDTE Energy St. Clair Power Plant
DTE Energy St. Clair Power Plant Unit 6 Scrubber Basins CCR Rule Compliance Project Annual Inspection Report - 2017 Project Number: 60546402 June 30, 2017 Prepared by: 27777 Franklin Road, Suite 2000 Southfield,
More information2016 Annual Dam and Dike Inspection Report
21 Annual Dam and Dike Inspection Report Fly Ash Pond and Bottom Ash Pond Complex Big Sandy Plant Kentucky Power Lawerance County, KY December 9, 21 Prepared for: Kentucky Power Big Sandy Plant Louisa,
More informationVICINITY MAP AND SITE MAP. Page 1 of 9
INTRODUCTION... 2 1. Background Information of West Bottom Ash Pond (BAP)... 2 1.1 Facility Location Description...2 1.2 Description of West BAP CCR Unit...2 1.2.1 Embankment Configuration...2 1.2.2 Construction
More informationTable of Contents. Attachments Attachment A Photos Attachment B Inspection Map. Pages 3 of 10
Table of Contents 1.0 Introduction...4 2.0 Description of Landfill...4 3.0 Review of Available Information...5 4.0 Inspection...5 4.1 Changes in Geometry since Last Inspection...5 4.2 Volume...5 4.3 Definitions
More information2017 Annual Landfill Inspection Report
2017 Annual Landfill Inspection Report Ash Landfill Welsh Plant American Electric Power Service Corporation (SWEPCO) Cason, Texas November 17, 2017 Prepared for: SWEPCO. Prepared by: American Electric
More informationDTE Energy Monroe Power Plant
DTE Energy Monroe Power Plant Inactive Bottom Ash Impoundment CCR Rule Compliance Project Annual Inspection Report - 2018 Project Number: 60516675 September 7, 2018 Prepared by: 27777 Franklin Road, Suite
More informationLyon Creek Cedar Way Stormwater Detention Dam Operation and Maintenance Manual
Lyon Creek Cedar Way Stormwater Detention Dam Operation and Maintenance Manual Prepared by: Mike Shaw Stormwater Program Manager City of Mountlake Terrace January 2010 Section I General Information This
More information2016 ANNUAL INSPECTION REPORT W.H. Sammis Coal Plant South Pond Stratton, Ohio
Prepared for: FirstEnergy Generation, LLC 76 South Main St Akron, Ohio 44308 2016 ANNUAL INSPECTION REPORT W.H. Sammis Coal Plant South Pond Stratton, Ohio Prepared by: 10211 Wincopin Circle, Floor 4 Columbia,
More informationHISTORY OF CONSTRUCTION 40 CFR (c)(1)(i) (xii) PLANT HAMMOND ASH POND (AP 2) GEEORGIA POWER COMPANY
HISTORY OF CONSTRUCTION 40 CFR 257.73(c)(1)(i) (xii) PLANT HAMMOND ASH POND (AP 2) GEEORGIA POWER COMPANY (i) Site Name and Ownership Information: Site Name: Plant Hammond Site Location: Site Address:
More information2016 ANNUAL DAM AND DIKE INSPECTION REPORT
2016 ANNUAL DAM AND DIKE INSPECTION REPORT Fly Ash Dams 1, 2 & Bottom Ash Pond Complex Cardinal PLANT BRILLIANT, OHIO December, 2016 Prepared for: Cardinal Operating Company Brilliant, Ohio Prepared by:
More informationMcElroy s Run Impoundment Coal Combustion Residual Annual Report
Allegheny Energy Supply Company, LLC A FirstEnergy Company Pleasants Power Station Pleasants County, West Virginia GAI Project Number: C150917.01 January 2016 Prepared for: Allegheny Energy Supply Company,
More informationAnnual Inspection Report CCR Surface Impoundment. MidAmerican Energy Company, Louisa Generating Station
Annual Inspection Report CCR Surface Impoundment MidAmerican Energy Company, Louisa Generating Station Final January 15, 2016 Annual Inspection Report CCR Surface Impoundment Prepared for MidAmerican Energy
More informationTable of Contents. Attachments Attachment A Photos Attachment B Site Map. Pages 3 of 9
Table of Contents 1.0 Introduction...4 2.0 Description of Landfill...4 3.0 Review of Available Information...5 4.0 Inspection...5 4.1 Changes in Geometry since Last Inspection...5 4.2 Volume...5 4.3 Definitions
More informationSTRUCTURAL STABILITY ASSESSMENT
STRUCTURAL STABILITY ASSESSMENT CFR 257.73(d) Pond 21, Pond 22, Pond 23 & WWSP Oklaunion Power Station Vernon, Texas October, 2016 Prepared for: Public Service Company of Oklahoma Prepared by: American
More information2018 Annual Landfill Inspection Report
2018 Annual Landfill Inspection Report ortheastern Plant Landfill Public Service Company of Oklahoma Oolagah, OK October 5, 2018 Prepared for: Public Service Company of Oklahoma ortheastern Plant Prepared
More informationMcElroy s Run Impoundment Structural Stability Assessment Report
Allegheny Energy Supply Company, LLC A FirstEnergy Company Pleasants Power Station Pleasants County, West Virginia October 2016 Prepared for: Allegheny Energy Supply Company, LLC A FirstEnergy Company
More informationCCR Rule Annual Inspection Report 2
Inspection Description An ARCADIS team performed the Trimble County Gypsum Storage Pond (GSP) 2015 annual inspection by a qualified professional engineer. The overall goal of the inspection was to ensure
More informationPond Closure - Case Study[TP1]
2017 World of Coal Ash (WOCA) Conference in Lexington, KY - May 9-11, 2017 http://www.flyash.info/ Pond Closure - Case Study[TP1] By Pedro J Amaya, P.E. (1) (1) Civil Engineering and Geotechnical Engineering
More informationHISTORY OF CONSTRUCTION 40 CFR (c)(1)(i)-(xii) PLANT MCDONOUGH ASH POND 1 (AP-1) GEORGIA POWER COMPANY
HISTORY OF CONSTRUCTION 40 CFR 257.73(c)(1)(i)-(xii) PLANT MCDONOUGH ASH POND 1 (AP-1) GEORGIA POWER COMPANY (i) Site Name and Ownership Information: Site Name: Site Location: Site Address: Owner: Address:
More informationJim Bridger Power Plant
2015 Coal Combustion Residuals Annual Inspection Jim Bridger Power Plant Industrial Landfill Prepared for PacifiCorp Energy North Temple Office 1407 West North Temple Salt Lake City, Utah 84116 Final December
More informationSTRUCTURAL STABILITY ASSESSMENT
STRUCTURAL STABILITY ASSESSMENT CFR 257.73(d) East and West Bottom Ash Pond Pirkey Plant Hallsville, Texas October, 2016 Prepared for: Southwest Electric Power Company (SWEPCO) - Pirkey Plant Hallsville,
More informationHISTORY OF CONSTRUCTION 40 CFR (c)(1)(i)-(xii) PLANT WANSLEY ASH POND (AP-1) GEORGIA POWER COMPANY. Carrollton, Georgia 30116
(i) Site Name and Ownership Information: HISTORY OF CONSTRUCTION 40 CFR 257.73(c)(1)(i)-(xii) PLANT WANSLEY ASH POND (AP-1) GEORGIA POWER COMPANY Site Name: Site Location: Site Address: Owner: Owner Address:
More informationMr. Michael Malone CPS Energy 145 Navarro Street San Antonio, Texas Project No
Environmental Resources Management January 13, 2017 Mr. Michael Malone 145 Navarro Street San Antonio, Texas 78205 Project No. 0352436 CityCentre Four 840 West Sam Houston Parkway North, Suite 600 Houston,
More informationINFLOW DESIGN FLOOD CONTROL SYSTEM PLAN 40 C.F.R. PART PLANT BOWEN ASH POND 1 (AP-1) GEORGIA POWER COMPANY
INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN 40 C.F.R. PART 257.82 PLANT BOWEN ASH POND 1 (AP-1) GEORGIA POWER COMPANY EPA s Disposal of Coal Combustion Residuals from Electric Utilities Final Rule (40 C.F.R.
More informationPOST CLOSURE PLAN. CFR (d) Pond 1. Clinch Power Plant Russell County, West Virginia. November Prepared for: Appalachian Power Company
POST CLOSURE PLAN CFR 257.104(d) Pond 1 Clinch Power Plant Russell County, West Virginia November 2016 Prepared for: Appalachian Power Company Prepared by: Amec Foster Wheeler Environment & Infrastructure,
More informationWatershed size and name: The drainage area is acres. The pond is located within the Ohio River watershed. (2016 Inflow Design Plan)
A. B. Brown History of Construction 40 CFR 257.73 (c) (i.) (ii.) (iii.) Owner Name: Southern Indiana Gas and Electric Company dba Vectren Power Supply Owner Address: One Vectren Square, PO Box 209, Evansville,
More informationAnnual Inspection Report North CCR Surface Impoundment. MidAmerican Energy Company, Walter Scott Energy Center
Annual Inspection Report North CCR Surface Impoundment MidAmerican Energy Company, Walter Scott Energy Center Rev 0 July 2018 Annual Inspection Report North CCR Surface Impoundment Prepared for MidAmerican
More informationCLOSURE PLAN. CFR (b) Document No. GERS Stingy Run Flyash Pond. Gavin Plant Cheshire, Ohio. October, 2016
CLOSURE PLAN CFR 257.102(b) Stingy Run Flyash Pond Gavin Plant Cheshire, Ohio October, 2016 Prepared for: AEP Generation Resources Gavin Plant Cheshire, Ohio Prepared by: American Electric Power Service
More informationCCR Annual Inspection (b) for the Ash Pond at the A.B. Brown Generating Station. Revision 0
Submitted to Southern Indiana Gas & Electric Company dba Vectren Power Supply, Inc. (SIGECO) One Vectren Square Evansville, IN 47708 Submitted by AECOM 9400 Amberglen Boulevard Austin, Texas 78729 257.83
More informationCoal Combustion Facility Assessment Report. October 20, 2010
Coal Combustion Facility Assessment Report October 20, 2010 Introduction Stantec Consulting Services Inc. North American Consulting Firm 10,000 Engineers, Geologists, Architects, Scientists and Technicians
More informationNaughton Power Plant
2017 Coal Combustion Residuals Annual Inspection Naughton Power Plant North Ash Pond Prepared for PacifiCorp Energy North Temple Office 1407 West North Temple Salt Lake City, Utah 84116 November 29, 2017
More informationTVA Colbert Fossil Facility Ash Disposal Pond 4
2011 World of Coal Ash (WOCA) Conference May 9-12, 2011 in Denver, CO, USA http://www.flyash.info/ TVA Colbert Fossil Facility Ash Disposal Pond 4 Improving Operations While Preparing for Closure May 10,
More informationReport. Inflow Design Flood Control System Plan Belle River Power Plant East China, Michigan. DTE Energy Company One Energy Plaza, Detroit, MI
Report Inflow Design Flood Control System Plan Belle River Power Plant East China, Michigan DTE Energy Company One Energy Plaza, Detroit, MI October 14, 2016 NTH Project No. 62-160047-04 NTH Consultants,
More informationCoal Combustion Residuals Unit Structural Stability Assessment
Coal Combustion Residuals Unit Structural Stability Assessment Virginia Electric and Power Company Chesterfield Power Station Upper (East) Pond Chesterfield County, Virginia GAI Project Number: C1500035.00
More informationActive Coal Combustion Residuals Landfill Annual Inspection Escalante Generating Station
REPORT Active Coal Combustion Residuals Landfill Annual Inspection Escalante Generating Station Submitted to: Tri-State Generation and Transmission Association, Inc. 1100 West 116th Avenue Westminster,
More informationINFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GASTON GYPSUM POND ALABAMA POWER COMPANY
INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GASTON GYPSUM POND ALABAMA POWER COMPANY Section 257.82 of EPA s regulations requires the owner or operator of an existing or new CCR surface impoundment or
More informationINFLOW DESIGN FLOOD CONTROL SYSTEM PLAN 40 C.F.R. PART PLANT YATES ASH POND 3 (AP-3) GEORGIA POWER COMPANY
INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN 40 C.F.R. PART 257.82 PLANT YATES ASH POND 3 (AP-3) GEORGIA POWER COMPANY EPA s Disposal of Coal Combustion Residuals from Electric Utilities Final Rule (40 C.F.R.
More informationPOST CLOSURE PLAN. CFR (d) Bottom Ash Pond Complex. Cardinal Plant. Brilliant, Ohio. September, 2016
POST CLOSURE PLAN CFR 257.104(d) Bottom Ash Pond Complex Cardinal Plant Brilliant, Ohio September, 2016 Prepared for: Cardinal Operating Company Cardinal Plant Brilliant, Ohio Prepared by: Geotechnical
More informationSuitable Applications Where concentrated flow of surface runoff must be conveyed down a slope in order to prevent erosion.
Categories EC Erosion Control SE Sediment Control TC Tracking Control WE Wind Erosion Control Non-Stormwater NS Management Control Waste Management and WM Materials Pollution Control Legend: Primary Objective
More informationINFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT BARRY ASH POND ALABAMA POWER COMPANY
INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT BARRY ASH POND ALABAMA POWER COMPANY Section 257.82 of EPA s regulations requires the owner or operator of an existing or new CCR surface impoundment or any
More informationVisual Inspection Checklist
APPENDIX Q. Visual Inspection Checklist Thispageintentionallyleftblank. VISUAL INSPECTION CHECKLIST CITY OF AUBURN PUBLIC WORKS DEPARTMENT INSPECTION YEAR: TYPE OF INSPECTION: (Informal, Regular, Formal):
More informationINITIAL RUN-ON AND RUN-OFF CONTROL PLAN 40 C.F.R. PART 257
INITIAL RUN-ON AND RUN-OFF CONTROL PLAN 40 C.F.R. PART 257.81 HUFFAKER ROAD (PLANT HAMMOND) PRIVATE INDUSTRIAL LANDFILL (HUFFAKER ROAD LANDFILL) GEORGIA POWER COMPANY EPA s Disposal of Coal Combustion
More informationINFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GREENE COUNTY ASH POND ALABMA POWER COMPANY
INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GREENE COUNTY ASH POND ALABMA POWER COMPANY Section 257.82 of EPA s regulations requires the owner or operator of an existing or new CCR surface impoundment
More informationHISTORY OF CONSTRUCTION 40 CFR (c)(1)(i)-(xii) PLANT MCDONOUGH ASH POND 2 (AP-2) GEORGIA POWER COMPANY
HISTORY OF CONSTRUCTION 40 CFR 257.73(c)(1)(i)-(xii) PLANT MCDONOUGH ASH POND 2 (AP-2) GEORGIA POWER COMPANY (i) Site Name and Ownership Information: Site Name: Site Location: Site Address: Owner: Address:
More informationCCR Annual Inspection (b) for the Ash Pond at the A.B. Brown Generating Station. Revision 0
Submitted to Southern Indiana Gas & Electric Company dba Vectren Power Supply, Inc. (SIGECO) One Vectren Square Evansville, IN 47708 Submitted by AECOM 9400 Amberglen Boulevard Austin, Texas 78729 257.83
More informationGreen CCR Landfill. Disposal of Coal Combustion Residuals (CCR) from Electric Utilities Final Rule CCR Landfill 2017 Annual Inspection Report
Green CCR Landfill Disposal of Coal Combustion Residuals (CCR) from Electric Utilities Final Rule CCR Landfill 2017 Annual Inspection Report January 11, 2018 Prepared By: Project ID: 170138B Big Rivers
More informationRun-on and Run-off Control System Plan
Run-on and Run-off Control System Plan SWEPCO John W. Turk, Jr. Power Plant Fulton, Arkansas Permit No. 0311-S3N-R1 AFIN: 29-00506 October 2016 Terracon Project No. 35167133 Prepared for: SWEPCO 3711 Highway
More informationAnnual Inspection Report Jeffrey Energy Center Flue Gas Desulfurization (FGD) Landfill
Annual Inspection Report Jeffrey Energy Center Flue Gas Desulfurization (FGD) Landfill Prepared for: Westar Energy Jeffrey Energy Center St. Marys, Kansas Prepared by: APTIM Environmental & Infrastructure,
More informationVISUAL SITE INSPECTION REPORT
VISUAL SITE INSPECTION REPORT - 2016 SOUTHERN INDIANA GAS AND ELECTRIC A. B. BROWN GENERATING STATION TYPE III RESTRICTED WASTE LANDFILL WEST FRANKLIN, IN ATC PROJECT NO. 170LF00318 DECEMBER 20, 2016 PREPARED
More informationCCR Rule Operating Criteria Closure Plan
CCR Rule Operating Criteria 257.102 Closure Plan FGD Pond 2 Jim Bridger Plant Point of Rocks, Wyoming PREPARED FOR PacifiCorp 1407 West North Temple Salt Lake City, UT 84116 (801) 521-0376 Fax (801) 220-4748
More informationAPPENDIX III Hydrologic and Hydraulic Evaluations
APPENDI III Hydrologic and Hydraulic Evaluations Hydrologic and Hydraulic Analysis Related to Compliance Requirements South Fly Ash Pond, Boiler Slag Pond and Clearwater Pond Kyger Creek Power Plant, Gallia
More informationFormal Annual Inspection It is recommended that you customize this form to fit your dam. Pre-Inspection Information
Formal Annual Inspection It is recommended that you customize this form to fit your dam. Pre-Inspection Information Name of Dam: Inspection Date: Current Weather: Weather During Last Week: Name of Creek,
More informationGreen CCR Landfill. Disposal of Coal Combustion Residuals (CCR) from Electric Utilities Final Rule CCR Landfill 2016 Annual Inspection Report
Green CCR Landfill Disposal of Coal Combustion Residuals (CCR) from Electric Utilities Final Rule CCR Landfill 2016 Annual Inspection Report January 10, 2017 Prepared By: Project ID: 160122B Big Rivers
More informationINITIAL INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT MCMANUS ASH POND A (AP-1) 40 CFR
INITIAL INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT MCMANUS ASH POND A (AP-1) 40 CFR 257.82 EPA s Disposal of Coal Combustion Residuals from Electric Utilities Final Rule (40 C.F.R. Part 257 and Part
More informationFly Ash Reservoir II Dam Initial Safety Factor Assessment. Cardinal Power Plant Brilliant, Ohio S&ME Project No A
Fly Ash Reservoir II Dam Initial Safety Factor Assessment Cardinal Power Plant Brilliant, Ohio S&ME Project No. 7217-15-006A Prepared for: American Electric Power 1 Riverside Plaza, 22 nd Floor Columbus,
More informationLimited Visual Dam Safety Inspections OA Wahiawa Dam. Oahu, Hawaii
Limited Visual Dam Safety Inspections OA00017 Wahiawa Dam Oahu, Hawaii Prepared by: U.S. ARMY CORPS OF ENGINEERS HONOLULU DISTRICT STATE OF HAWAII DEPARTMENT OF LAND AND NATURAL RESOURCES May 2006 Dam
More informationHISTORY OF CONSTRUCTION FOR EXISTING CCR SURFACE IMPOUNDMENT PLANT MCMANUS ASH POND A (AP-1) 40 CFR (c)(1)(i)-(xii)
HISTORY OF CONSTRUCTION FOR EXISTING CCR SURFACE IMPOUNDMENT PLANT MCMANUS ASH POND A (AP-1) 40 CFR 257.73(c)(1)(i)-(xii) (i) Site Name and Ownership Information: Site Name: Site Location: Site Address:
More informationPleasants Power Station Landfill Coal Combustion Residual 2017 Annual Report
Allegheny Energy Supply Company, LLC A FirstEnergy Company Pleasants County, West Virginia December 2017 Prepared for: Allegheny Energy Supply Company, LLC A FirstEnergy Company 800 Cabin Hill Drive Greensburg,
More information4. Present Activities and Roles
4. Present Activities and Roles The present missions, authorities, activities and roles of the various agencies involved with flood protection, floodplain management and flood-damage reduction are identified
More informationENGINEERING CHECKLIST SEDIMENT & STORMWATER MANAGEMENT BASIN CONSTRUCTION
NEW CASTLE COUNTY DEPARTMENT OF LAND USE ENGINEERING CHECKLIST SEDIMENT & STORMWATER MANAGEMENT BASIN CONSTRUCTION For Permanent Structures, pursuant to Delaware Pond Code 378 and Delaware Sediment and
More informationCCR Annual Inspection (b) for the West Ash Pond at the F. B. Culley Generating Station. Revision 0
Submitted to Southern Indiana Gas & Electric Company dba Vectren Power Supply, Inc. (SIGECO) One Vectren Square Evansville, IN 47708 Submitted by AECOM 9400 Amberglen Boulevard Austin, Texas 78729 257.83
More informationTypes of Inspections. Prior to Inspection. Types of Inspections. Typical Inspection Equipment. Embankment Dams
BIA Summer Water Resources Training Dam Safety Inspections Part 4 - Inspections July 28, 2012 Presented by Michael Johnson, Ph.D., P.E. Types of Inspections Periodic Inspections A comprehensive visual
More informationPOST CLOSURE PLAN. CFR (d) GERS Landfill. Mitchell Power Plant Marshall County, West Virginia. October, 2016
POST CLOSURE PLAN CFR 257.104(d) Landfill Mitchell Power Plant Marshall County, West Virginia October, 2016 Prepared for: Wheeling Power Company & Kentucky Power Company Prepared by: American Electric
More informationALLIANT ENERGY INTERSTATE POWER AND LIGHT OTTUMWA GENERATING STATION CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT.
ALLIANT ENERGY INTERSTATE POWER AND LIGHT OTTUMWA GENERATING STATION CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT January 15, 2016 EXECUTIVE SUMMARY This annual inspection report has been prepared
More informationDam Safety Inspection Checklist
Dam Safety Inspection Checklist Complete All Portions of This Section (Pre-inspection) Date of Inspection: Name of Dam: EAP: (yes, no) OM&I: (yes, no) File Number: Review Inventory - Highlight missing
More informationReport. Inflow Design Flood Control System Plan St. Clair Power Plant St. Clair, Michigan. DTE Energy Company One Energy Plaza, Detroit, MI
Report Inflow Design Flood Control System Plan St. Clair Power Plant St. Clair, Michigan DTE Energy Company One Energy Plaza, Detroit, MI October 14, 2016 NTH Project No. 62-160047-04 NTH Consultants,
More informationSediment Control Practices
Sediment Control Practices SMP-05 Temporary Diversions, Berms or Ditches Symbol TD Description These temporary drains offer features such as conveyance for runoff down cut or fill slopes, subsurface drains
More informationConstruction Inspection Checklists
III. Construction Inspection Checklists 33 Bioretention - Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: Construction Sequence Satisfactory / Unsatisfactory Comments
More informationCONSTRUCTION PLAN CHECKLIST
CONSTRUCTION PLAN CHECKLIST The design engineer is responsible for ensuring that plans submitted for city review are in accordance with this checklist. It is requested that the executed checklist be submitted
More information1.1 Background Facility Description REVIEW OF AVAILABLE INFORMATION Information Reviewed... 2
Table of Contents 1.0 INTRODUCTION... 1 1.1 Background... 1 1.2 Facility Description... 1 2.0 REVIEW OF AVAILABLE INFORMATION... 2 2.1 Information Reviewed... 2 2.2 Changes in Facility Geometry... 2 2.3
More informationDam Safety Surveillance. Templates for very low, low consequence category dams
Dam Safety Surveillance Templates for very low, low consequence category dams The State of Victoria Department of Environment, Land, Water and Planning 2015 This work is licensed under a Creative Commons
More informationPOST CLOSURE PLAN. CFR (d) GERS East and West Bottom Ash Ponds. Pirkey Power Plant Hallsville, Texas. October, 2016
POST CLOSURE PLAN CFR 257.104(d) East and West Bottom Ash Ponds Pirkey Power Plant Hallsville, Texas October, 2016 Prepared for: Southwest Electric Power Company Pirkey Power Plant Hallsville, Texas Prepared
More informationEROSION CONTROL GENERAL NOTES EC JAN 2017 C.B.
EROSION CONTROL GENERAL NOTES EC - 000 EROSION CONTROL GENERAL NOTES EC - 001 INSTALL TEMPORARY DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT EXISTING PAVEMENT OR APPROVED ACCESS POINT OR AS PRACTICABLE
More informationHarrison Landfill Run-on and Run-off Control System Plan
Harrison Landfill Run-on and Run-off Control System Plan Monongahela Power Company A FirstEnergy Company Harrison Power Station Shinnston, Harrison County, West Virginia October 2016 Prepared for: Monongahela
More informationINSPECTION REPORT. Third Annual RCRA CCR Unit Inspection Report January 2018 WASTE DISPOSAL AREA SURFACE IMPOUNDMENT
INSPECTION REPORT NORTHERN INDIANA PUBLIC SERVICE COMPANY R.M. SCHAHFER GENERATING STATION Third Annual RCRA CCR Unit Inspection Report January 2018 WASTE DISPOSAL AREA SURFACE IMPOUNDMENT Submitted To:
More informationCCR Annual Inspection (b) for the Ash Pond at the A.B. Brown Generating Station. Revision 0
Submitted to Southern Indiana Gas & Electric Company dba Vectren Power Supply, Inc. (SIGECO) One Vectren Square Evansville, IN 47708 Submitted by AECOM 9400 Amberglen Boulevard Austin, Texas 78729 257.83
More informationVISUAL SITE INSPECTION REPORT 2018
VISUAL SITE INSPECTION REPORT 2018 SOUTHERN INDIANA GAS AND ELECTRIC A. B. BROWN GENERATING STATION TYPE III RESTRICTED WASTE LANDFILL WEST FRANKLIN, IN ATC PROJECT NO. 170LF00614 January 9, 2019 PREPARED
More information4.4.6 Underground Detention
4.4.6 Underground Detention Limited Application Water Quality BMP Description: Detention storage located in underground pipe systems or vaults designed to provide water quantity control through detention
More information2017 Annual Surface Impoundment Inspection
2017 Annual Surface Impoundment Inspection Cell 3 Prepared for Minnkota Power Cooperative, Inc. Milton R. Young Station January 2018 2017 Annual Surface Impoundment Inspection Cell 3 Prepared for Minnkota
More informationDAM INSPECTION CHECKLIST Department of Environmental Protection Bureau of Waterways Engineering Division of Dam Safety
DAM INSPECTION CHECKLIST Department of Environmental Protection Bureau of Waterways Engineering Division of Dam Safety NAME OF DAM: Milltown Dam DEPDAMNO.: 15-146 LOCATION: Municipality: East Goshen Township
More informationPOST CLOSURE PLAN. CFR (d) GERS Fly Ash Pond. Big Sandy Plant Louisa, Kentucky. October, 2016
POST CLOSURE PLAN CFR 257.104(d) Fly Ash Pond Big Sandy Plant Louisa, Kentucky October, 2016 Prepared for : Kentucky Power Big Sandy Plant Louisa, Kentucky Prepared by: American Electric Power Service
More informationALLIANT ENERGY WISCONSIN POWER AND LIGHT COLUMBIA ENERGY CENTER CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT. January 15, 2016
ALLIANT ENERGY WISCONSIN POWER AND LIGHT COLUMBIA ENERGY CENTER CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT January 15, 2016 EXECUTIVE SUMMARY This annual inspection report has been prepared in accordance
More informationNAUGHTON FGD POND 4 STRUCTURAL STABILITY ASSESSMENT
NAUGHTON FGD POND 4 STRUCTURAL STABILITY ASSESSMENT Prepared for: PacifiCorp, Naughton Power Plant Project Manager: Chad Tomlinson Date: 01 September 2016 Document No.: NP-TR-014 Quality Assurance Statement
More informationEmergency Action Plan for Coal Combustion Residuals Unit
Emergency Action Plan for Coal Combustion Residuals Unit J. R. Whiting Facility 22581014.00 Prepared for Consumers Energy Company April 2017 Barr Engineering Co. 3005 Boardwalk Street, Suite 100 Ann Arbor,
More informationINITIAL RUN-ON AND RUN-OFF CONTROL PLAN 40 C.F.R. PART 257
INITIAL RUN-ON AND RUN-OFF CONTROL PLAN 40 C.F.R. PART 257.81 PLANT BOWEN PRIVATE INDUSTRY SOLID WASTE DISPOSAL FACILITY (ASH LANDFILL) GEORGIA POWER COMPANY EPA s Disposal of Coal Combustion Residuals
More informationTypes of Inspections
BIA Summer Water Resources Training Dam Safety Inspections Part 4 - Inspections July 28, 2012 Presented by Michael Johnson, Ph.D., P.E. Types of Inspections Periodic Inspections A comprehensive visual
More informationCoal Combustion Residuals Inflow Design Flood Control System Plan
gaiconsultants.com I transforming ideas into reality., Coal Combustion Residuals Inflow Design Flood Control System Plan Virginia Electric and Power Company Possum Point Power Station Surface Impoundment
More informationCCR Certification: Initial Structural Stability Assessment (d)
Submitted to Southern Indiana Gas & Electric Company dba Vectren Power Supply, Inc. (SIGECO) One Vectren Square Evansville, IN 47708 Submitted by AECOM 9400 Amberglen Boulevard Austin, Texas 78729 CCR
More informationVIA . September 19, Mr. Jeffrey Maxted Alliant Energy Sr. Environmental Specialist 4902 North Biltmore Lane Madison, WI
932 N. Wright Street, Suite 160, Naperville, IL 60563 Phone (877) 630-7428 www.hardhatinc.com VIA EMAIL September 19, 2016 Mr. Jeffrey Maxted Alliant Energy Sr. Environmental Specialist 4902 North Biltmore
More information