SINGLE OCCUPANCY PUBLIC RESTROOMS AT UNH - DURHAM
|
|
- Joseph Horton
- 6 years ago
- Views:
Transcription
1 SINGLE OCCUPANCY PUBLIC RESTROOMS AT UNH - DURHAM Single occupancy restrooms are equipped with locks. The accessible restrooms are located on an accessible route and useable with a mobility device. Please note that single occupancy restrooms may be used by anyone even when the room sign indicates a gender designation. Building Name Access tes 1 Leavitt Lane Flush handle against wall 1 Leavitt Lane Urinal 26" rim; limited wheelchair access 10 West Edge Drive- Printing & Mailing 01 G01D 60"x60" clear floor space, front transfer only 10 West Edge Drive- Printing & Mailing 01 G01C 60"x60" clear floor space, front transfer only 10 West Edge Drive- Institute on Disability "x60" clear floor space; 11 Brook Way B B01B 20"x47" clear floor space 18 Waterworks Road Horizontal and vertical grab bars, 60"x60" clear floor space, auto sink 18 Waterworks Road A Front transfer only 18 Waterworks Road CC Chase Ocean Engineering Building Chase Ocean Engineering Building Dairy Bar/ RR Station "x83" clear floor space, lever style sink handles, front approach to water closet; tight maneuvering clearance at door 45"x83" clear floor space, lever style sink handles, front approach to water closet; tight maneuvering clearance at door Push button sink faucet, Low knee space below sink, steep threshold from main dining to restrooms Dairy Bar/ RR Station Push button sink faucet, Low knee space below sink steep threshold from main dining to restrooms
2 Access tes DeMeritt Hall yes sink faucets Dimond Library yes Dimond Library G G02 Paper towel dispenser overhangs a portion of the grab bar Elliot Alumni Center "x31" clear floor space, no grab bars Elliot Alumni Center "x31" clear floor space, no grab bars Elizabeth Demeritt House B B03 Elizabeth Demeritt House 01 A105 Lever handles, Flush handle on open side, Vertical and horizontal grab bars. Lever handles, Flush handle on open side, Vertical and horizontal grab bars. Elizabeth Demeritt House Elizabeth Demeritt House Flow Physics Facility B Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles
3 Access tes Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles Gregg Hall "x59" clear floor space, push sink handles Hamilton-Smith Hall Building is under renovation Health Services Dispensers above 48" Health Services Health Services Health Services Dispensers above 48" Health Services Hood House B B07AB step - 56x54 inches - not wheelchair accessible; there are grab bars Hood House wheelchair accessible Hood House not wheelchair accessible Horton A
4 Access tes Housing Office (10 Academic Way) Huddleston Hall A accessible route, t wheelchair accessible Human Resources (1 Leavitt Lane) Small lever sink handles Human Resources (1 Leavitt Lane) Small lever sink handles Kendall Hall Front transfer only Kendall Hall Leavitt Central Receiving A Leavitt Central Receiving B Leavitt Central Receiving step up into bathroom; no accessible stall; urinal at 24" Light Horse Classroom restricted maneuvering space, knob sink handles McConnell Hall yes Auto faucet, auto flush McConnell Hall Grab bars, auto flush, auto faucet Memorial Union Building
5 Access tes Moiles House Moiles House Murkland Murkland Nesmith Hall yes 44"x93" clear floor space in front of toilet, auto sink faucets NH Hall G Shower not accessible Parsons B NB13 sink Parsons 01 N145 yes Parsons 01 W101 t wheelchair accessible Parsons 01 S120 flush and sink Paul College Ground G73 310F Accessible Public Single Occupancy Restroom flush and faucet, Restricted Use
6 Access tes PCAC 02 A211 Serves Level 2 Art Department and Museum of Art PCAC 01 M120 Serves Bratton Recital Hall and Level 1 Music Department Perpetuity Hall Perpetuity Hall Pettee Hall paper towel dispenser at 53" - soap dispenser at 50" Pettee Hall not wheelchair accessible Pettee Hall Paper towel dispenser at 53" - soap dispenser at 53" Ritzman accessible route Ritzman "x60" clear floor space, sink has lever style handle, accessible route Ritzman t wheelchair accessible Service Building G G14A t wheelchair accessible, knee space below sink, Service Building G G15 t wheelchair accessible, Urinal rim at 20" Service Building Side grab bars attached to toilet, accessible through library way entrance
7 Access tes Smith Hall A Lever sink handles Smith Hall B G04 55"x98' clear floor space Smith Equine Center Minimal turning radius. Restricted side transfer Smith Equine Center Minimal turning radius. Restricted side transfer Stillings G G62 Lever style handles Stillings G G60 Lever style handles Stoke table outside of stall; tight clearance in stall (door opens in). Stoke G G20D Lever style handles, Located within business services Stoke G G20C 32"x68" clear floor space infront of toilet, auto flush toilet, knob style sink handles Stoke G G80C Located inside the Financial Aid office, tight maneuvering space at the door Stoke G G80E Found inside the Financial Aid office, tight maneuvering space Telecom Center "x60" maneuvering space, flush on open side Telecom Center A Route blocked by storage room, knob style sink handles, 18"x40" clear floor space
8 Access tes Thompson Hall G G07 standard sink handles Thompson Hall A standard sink handles; paper towel despenser at 54"; limited side transfer Thompson Hall B not wheelchair accessible; standard sink handles Visitor Center front transfer only at water closet, 47"x116" clear floor space in front of toilet Visitor Center front transfer only at water closet, 47"x116" clear floor space in front of toilet Whittemore Center R R35 Accessible Single Occupancy Restroom Urinal rim 24", auto flush Wolff House "x110" clear floor space, PT dispenser blocked by sink Wolff House "x110" clear floor space TOTAL SINGLE OCCUPANCY RESTROOMS 98 TOTAL CAMPUS BUILDINGS WITH SINGLE OCCUPANCY RESTROOMS TOTAL ACCESSIBLE SINGLE OCCUPANCY RESTROOMS The Single Occupancy Restroom list is maintained by the UNH Affirmative Action and Equity Office. Please contact the office to report any inaccuracies. Last updated December 2015
SINGLE OCCUPANCY RESTROOMS AT UNH - DURHAM
SINGLE OCCUPANCY RESTROOMS AT UNH - DURHAM Single occupancy restrooms are equipped with locks. The accessible restrooms are located on an accessible route and are useable with a mobility device. Please
More informationDEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE
DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS BOBBY JINDAL GOVERNOR Public Safety Services H. BUTCH BROWNING STATE FIRE MARSHAL ADA-ABA COMMENT ASSISTANCE GUIDE The information submitted is not sufficient
More informationPlan Check No. f) Where only half baths are provided, at least one half bath. g) Carports, garages or parking spaces. (1111B.4.2.
Plan Check No. A. GROUP R OCCUPANCIES 1. Hotels, motels, inns, dormitories, resorts, homeless shelters, halfway houses, transient group homes, and similar places of transient lodging shall provide access
More informationSite Accessibility Survey & Transition Plan
Site Accessibility Survey & Transition Plan Organization Name: Person Completing Form: Site Name: Site Address: Date Completed: Instructions: 1. Please circle the appropriate response for each question.
More informationBUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor
BUILDING/FACILITY ACCESSIBILITY CHECKLIST Location: Type of Building or Project 1. Is this a newly constructed building? Yes No a. Year plans were approved b. Year built 2. Is this an addition? Yes No
More informationSUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST
GEORGE CHAVEZ, City Building Official DAVID YELTON, Building Inspection Manager NESTOR OTAZU, Community Preservation Manager BUILDING & SAFETY DIVISION 455 North Rexford Drive, 1 st Floor Beverly Hills,
More informationAccessible Toilet and Bathing Rooms
Accessible Toilet and Bathing Rooms Building & Fire Safety Division Yakima County Public Services This brochure is for illustration purpose only. It is NOT a complete section of the referenced codes, nor
More informationACCESSIBLE REST ROOM Code Requirements
ACCESSIBLE REST ROOM Code Requirements Applicable Code References (Effective December 31, 2005) (Amendments effective August 1, 2009) 2003 International Building Code portion of the 2005 State Building
More informationTexas Accessibility Standards for Restrooms
Texas Accessibility Standards for Restrooms 2 PDH / 2 CE Hours/ 2 AIA LU/HSW Hours AIAPDH156 PDH Academy PO Box 449 Pewaukee, WI 53072 www.pdhacademy.com pdhacademy@gmail.com Final Exam 1. Mirrors located
More informationACCESSIBILITY CHECKLIST
ACCESSIBILITY CHECKLIST MARCH 2015 EDITION BASED ON THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN Northwest ADA Center University of Washington 6912 220th St S.W., Suite 105 Mountlake Terrace, WA 98043
More informationACCESSIBILITY CHECKLIST
ACCESSIBILITY CHECKLIST FEBRUARY 2014 EDITION BASED ON THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN Northwest ADA Center University of Washington 6912 220th St S.W., Suite 105 Mountlake Terrace, WA 98043
More informationRESTROOM/DRINKING FOUNTAIN REQUIREMENTS
CITY HALL 333 Broadalbin Street SW P.O. Box 490 Albany, OR 97321-0144 www.cityofalbany.net 541-917-7500 CITY MANAGER/ ECONOMIC DEVELOPMENT/ URBAN RENEWAL 541-917-7500 FA 541-917-7511 FINANCE Finance/Recorder
More informationAccessibility Survey Techniques John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc.
John Salmen, AIA Andrew Yarrish, AIA www. Outline of Program 1. Tools 2. Accessibility Checklists 3. Measurement Questions will be taken throughout 2 Objectives Become familiar with measuring techniques
More information2013 California Building Code Advisory
2013 California Building Code Advisory This document is provided courtesy of the Department of General Services, Division of the State Architect for California. The complete document contains the 2013
More informationCollins Middle School
Contents Collins Middle School...2 General comments, campus capacity, and student demographics:...2 1.0 School Site...4 2.0 Building Systems and Components...5 3.0 Building Safety and Security...19 4.0
More informationAccessible Plumbing Overview
Accessible Plumbing Overview CS3778 2012 NC Building Code 2009 ANSI A117.1 Prepared by: Laurel W. Wright Chief Accessibility Code Consultant NC Dept of Insurance/OSFM ANSI 104.2 Conv. Industry Tolerance
More informationPriority 2 Access to Goods & Services
Based on the 2010 ADA Standards for Accessible Design Project Building Location Date Surveyors Contact Information The layout of the building should allow people with disabilities to obtain goods and services
More information9/10/2009. Objectives ADA SURVEY TRAINING OFFICE BUILDINGS & COUNTY GARAGES. Training Schedule. Key Roles. Key Roles. Major Laws
Objectives Division of Facilities and Equipment Management Office of Facilities Operations Management ADA SURVEY TRAINING OFFICE BUILDINGS & COUNTY GARAGES Develop practical understanding of ADA guidelines
More informationAccessible Laneway and Carriage Houses: Supplemental Design Guidelines. Accessbility Features
Accessible Laneway and Carriage Houses: Supplemental Design Guidelines October 2018 Accessbility Features Accessible laneway and carriage houses can provide rental housing for a variety of people, including
More information2007 Title 24 Accessibility Code Updates and ADA Issues
2007 Title 24 Accessibility Code Updates and ADA Issues C.A.S.H. Workshop June 2007 Introduction Update on ADA Certification of the California Building Code Overview of significant changes to accessibility
More informationUniversal Design Standards
Universal Design Standards For applications submitted and approved after April 16, 2007 Introduction to Universal Design Universal design is a building concept that incorporates products, general design
More information2018 IBC SECTION 1209 DRAFT TEXT Copyright 2017 International Code Council, Inc. SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
2018 IBC SECTION 1209 DRAFT TEXT Copyright 2017 International Code Council, Inc. SECTION 1209 TOILET AND BATHROOM REQUIREMENTS [P] 1209.1 Required fixtures. The number and type of plumbing fixtures provided
More informationEVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN
EVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN - CREDIT(S) EARNED ON COMPLETION OF THIS COURSE WILL BE REPORTED TO AIA CES FOR AIA MEMBERS.
More informationACCESSIBLITY FACILITIES
ACCESSIBLITY FACILITIES Americans with Disabilities Act 1991 Chapters 11A and 11B are based on ADA 1991 but also differ from it. For this reason it is crucial to review the state requirements against the
More informationChapter 11. Dwelling Units and Sleeping Units
1101 General Chapter 11. Dwelling Units and Sleeping Units 1101.1 Scoping. Dwelling units and sleeping units required by the scoping provisions adopted by the administrative authority to be Accessible
More informationFlorida Accessibility Code for Building Construction
Florida Accessibility Code for Building Construction Accessibility Training Course Florida Building Commission Introduction Course will review the Florida Accessibility Code for Building Construction as
More informationCITY OF LOS ANGELES. Title 24, California Code of Regulations Accessibility Regulations Supplemental Correction List No. 1 (Effective )
CITY OF LOS ANGELES Title 24, California Code of Regulations Accessibility Regulations Supplemental Correction List No. 1 (Effective 11-01-2002) Sanitary Facilities, Drinking Fountains, Telephones, Alterations
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU COMMERCIAL ACCESSIBILITY PLAN REVIEW CHECKLIST
CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU COMMERCIAL ACCESSIBILITY PLAN REVIEW CHECKLIST PROJECT NO.: EXPIRATION DATE: STATUS: 1 st Review INFORMATION PROJECT ADDRESS:
More informationEducational Course Application
STATE OF WISCONSIN Department of Safety and Professional Services Educational Course Application Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.04(1)(m)]. Safety
More informationFlorida Accessibility Code for Building Construction
Florida Accessibility Code for Building Construction Accessibility Training Course Florida Building Commission 1 Introduction Course will review the Florida Accessibility Code for Building Construction
More informationCITY OF BEVERLY HILLS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION COMMERCIAL ACCESSIBILITY CORRECTION LIST
CITY OF BEVERLY HILLS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION COMMERCIAL ACCESSIBILITY CORRECTION LIST Activity No.: Address: Reviewer: Work Description: Type of Const.: Use:
More informationPlumbing for People with Disabilities
Plumbing for People with Disabilities Continuing Education from the American Society of Plumbing Engineers November 2016 ASPE.ORG/ReadLearnEarn CEU 241 READ, LEARN, EARN Note: In determining your answers
More informationORDINANCE NO. _ 10463
ADOPTED BY THE MAYOR AND COUNCIL October 16. 2007 ORDINANCE NO. _ 10463 ;._,;;. RELATING TO BUILDINGS AND CONSTRUCTION; ADOPTING BY REFERENCE PORTIONS OF THE 1998 AMERICAN NATIONAL STANDARD ACCESSIBLE
More informationCertificate of Occupancy Inspection Checklist Change of Use Group or Occupancy
Certificate of Occupancy Inspection Checklist Change of Use Group or Occupancy All of the following are REQUIRED when applicable (please see attached handouts for more details) Yes No N/A At least one
More informationTHE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2016 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New & Rehab
THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2016 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS New & Rehab The Virginia Housing Development Authority (VHDA) recognizes the need to create
More informationChapter Bottle Filling Stations. Bottle filling stations which shall comply with Sections and
Chapter 6 6-2 12 Revise as follows: 602 Drinking Fountains and Bottle Filling Stations. 602.7 Bottle Filling Stations. Bottle filling stations which shall comply with Sections 602.7.1 and 602.7.2. Exception:
More informationEMPLOLYMENT APPLICATION P.O. BOX 3810 BUTTE, MT
APPLICANT INFORMATION P.O. BOX 3810 BUTTE, MT 59701 406-494-3310 Last Name First M.I. Street of Birth City State ZIP Phone Available Position Applied for Social Security No. E-mail Desired Salary Are you
More informationSuccessful Restaurant. Accessibility. Accessibility. Did you sign in? Best Practices. Copyright Materials. Course Description
Successful Restaurant Accessibility Successful Restaurant Accessibility TDLR Provider #1521 AIA/CES Provider #G583 Michael Love APA ICC IIDA Best Practices Did you sign in? Accessibility Professionals
More informationConstruction Standards PAGE
Construction Standards PAGE 102810-1 SECTION 102810 - PART 1 - GENERAL 1.1 M.S.U. ISSUES A. Mirrors will normally be provided at all lavatory locations. Provide full-length mirror on adjacent wall for
More informationGUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New Construction & Rehab
GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS New Construction & Rehab Universal Design is the design of products and environments to be usable by all people, to the greatest extent possible,
More informationNC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning
1.0 Purpose A. These guidelines provide requirements for the Designer and Contractor to follow related to space planning. 2.0 General Requirements A. Single Occupant Toilet Room Each new or renovated building
More informationTOP 10 UNIVERSAL DESIGN IN THE BATHROOM: A R E A S O F F O C U S
TOP 10 UNIVERSAL DESIGN IN THE BATHROOM: A R E A S O F F O C U S SPACE THAT WORKS FOR EVERYONE Universal Design. Aging in Place. Accessible Design. Three terms with similar goals: to create living spaces
More informationExpanding Your Market
U.S. Department of Justice Civil Rights Division Disability Rights Section Expanding Your Market Maintaining Accessible Features in Retail Establishments Introduction More than 50 million Americans with
More information4. If more than 5 entrances to the building then 50% must be barrier free leading to the outside sidewalk or ramp.
BARRIER-FREE AUDITCHECKLIST YES NO N/A BUILDING ENTRANCES AND DOORS: 1. Are signs adequate to assist in locating accessible entrances? 2. Are the entrances clearly marked by the International Symbol of
More information10155 Toilet Compartments
10155 Toilet Compartments This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or
More informationACCESSIBILITY CHECKLIST
ACCESSIBILITY CHECKLIST Project Address: ALL forms that are required to be completed by this document are required to be reproduced on the plan set. 1 Proposed Use of the Project (e.g. Retail, Office,
More informationCommercial Accessibility Overview
Commercial Accessibility Overview 1 COLORADO CODE CONSULTING, LLC Copyright Materials This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use
More informationPROCEDURE PR California Building Code Accessibility Provisions as Alternate Means and Methods. Revised: October 3, 2013
2013 California Building Code Accessibility Provisions as Alternate Means and Methods Revised: October 3, 2013 PROCEDURE PR 13-03 Division of the State Architect (DSA) Procedures document processes or
More informationHANDICAPPED ACCESSIBILITY TOOLKIT - UPDATE By: Mike Ferguson, P.E. Director of Engineering Services Updated and Re-Issued September 9, 2014
HANDICAPPED ACCESSIBILITY TOOLKIT - UPDATE By: Mike Ferguson, P.E. Director of Engineering Services Updated and Re-Issued September 9, 2014 Based upon recent discussion and feedback from several clients,
More information1 Exam Prep Florida Building Code-Accessibility Edition Tabs and Highlights
1 Exam Prep Florida Building Code-Accessibility- 2014 Edition Tabs and s These 1 Exam Prep Tabs are based on the Florida Building Code-Accessibility-2014 Edition. Each 1 Exam Prep tabs sheet has five rows
More informationAddendum #2 3875Q Request for Quote Renovation of Old RCMP and Change Room at South Arm Community Centre
February 25, 2010 File: Business & Financial Services Department Telephone: 604-276-4097 Fax: 604-276-4162 Dear Sir/ Madame, Re: Addendum #2 3875Q Request for Quote Renovation of Old RCMP and Change Room
More informationCOMPLETION 30-DAY REVISIT CLOSED ASSIGNED DATE FACILITIES WORK ORDER NUMBER IEQ WORK ORDER NUMBER
01A. ODOR: Unusual or 6/7/2018 10:12:17 offensive Custodial closet 2 01A. ODOR: Unusual or 6/7/2018 10:29:04 offensive Upstairs boys bathroom 01A. ODOR: Unusual or 6/7/2018 11:01:53 offensive Upper boys
More informationFacility Improvements
AL-SI-02 ASPHALT PLAY AREA UPGRADE AL-SI-09 CURB RAMP ADDITIONS Asphalt improvements needed around building and playshed to provide a safe play area. Curb ramps needed to provide wheelchair access and
More informationGENERAL NOTES FOR COMMERICAL ACCESSIBILITY
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO: Various EFFECTIVE: 01-01-2017 DOCUMENT NO: P/BC 2017-143 REVISED: PREVIOUSLY ISSUED AS: N/A GENERAL NOTES FOR COMMERICAL ACCESSIBILITY NOTE:
More informationPUBLIC RESTROOMS, DESIGN INTENT Los Angeles World Airports
1.1 STRUCTURAL A. To the extent possible, metal stud partitions will be constructed on a 6 high concrete curb. B. Plumbing chase and Custodial Rooms will have 6 high concrete curb at all perimeter walls.
More informationElement Z General Design Requirements Owner Standards and other Requirements
PART 1 - GENERAL 1.01 OVERVIEW A. This document provides design and construction criteria for public/patient, and staff toilet rooms at M. D. Anderson Cancer Center (Owner). Toilet facilities located within
More informationGENERAL NOTES FOR COMMERCIAL ACCESSIBILITY
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO: Various EFFECTIVE: 01-01-2017 DOCUMENT NO: P/BC 2017-143 REVISED: 07-01-2018 PREVIOUSLY ISSUED AS: N/A GENERAL NOTES FOR COMMERCIAL ACCESSIBILITY
More informationAnnotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13
Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13 RED indicates new text. O. Reg. 368/13 comes into force on 1 January, 2015 DIVISION A PART 1 COMPLIANCE,
More informationSPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)
SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) Construction Criteria The unit costs for the Physical Fitness Center (Exercise Room) space type are based on the construction quality and design features in
More informationBUILDING CONDITION: INTERIOR
Typical interior finishes at the Main Building consist of VCT flooring, plaster walls, and lay in ceilings at classrooms and instructional spaces Corridors have terrazzo flooring and partial height glazed
More informationBENTON ANNEX ADA ASSESSMENT & SURVEY
OREGON STATE UNIVERSITY (OSU) BENTON ANNEX ADA ASSESSMENT & SURVEY Sacramento Office 770 L Street, Suite 950 Sacramento, CA 95814 Tel: 916.669.8750 Fax: 888.211.7441 Silicon Valley Office 2225 E. Bayshore
More informationCITY OF LOS ANGELES Department of Building and Safety Disabled Access Section RESIDENTIAL ACCESSIBILITY PLAN REVIEW LIST
GENERAL PROJECT INFORMATION PERMIT APPLICATION # PLAN CHECK NO JOB ADDRESS CITY ZIP REVIEWED BY PHONE DATE NOTE: Numbers in the parenthesis ( ) refer to sections of the 2014 edition of the Los Angeles
More informationDealership Requirements for a Certificate of Occupancy
Dealership Requirements for a Certificate of Occupancy 1. Property shall have at least 1 designated handicap accessible parking space The space is to have a minimum width of 132. This space is to be marked
More informationCorsicana High School
Contents Corsicana High School...2 General comments, campus capacity, and student demographics...2 1.0 School Site...4 2.0 Building Systems and Components...6 3.0 Building Safety and Security...19 4.0
More informationGFW Schools Task Force Meeting 1/23/19 R.A. MORTON & ASSOCIATES GLT ARCHITECTS 1
GFW Schools Task Force Meeting 1/23/19 1 AGENDA 1. Introductions 2. Review of building tours Primary Needs 3. Review Space Programs 4. Review Concept Options District and Facility needs 5. Review Concept
More informationC. Liquid Chalk Markerboards: Claridge Duracite LCS markerboard in No. 32 White finish on 3/8 inch-particle board.
DIVISION 10 SPECIALTIES 10100. CHALKBOARDS AND TACKBOARDS A. Acceptable Manufacturers: Claridge Products and Equipment, Inc. Harrison, Arkansas 72602-0910 501-743-2200 fax 501-743-1908 Greensteel Division
More informationFacilities Project Management Monthly Report by Building
Tuesday, June 05, 2018 Approved 153 Facilities Management Monthly Report by Building 1 Leavitt Lane s in Building 1 2016 0429 1 Leavitt Lane 123 renovation 5/30/18_ Work has been completed, customer has
More informationNew Construction & Rehabilitation
THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2018 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS New Construction & Rehabilitation The Virginia Housing Development Authority (VHDA) recognizes
More informationGoal. Graphic Conventions. Accessibility Code
Accessibility Update The 2015 Building Code of NY State Niagara Frontier Building Officials January 24, 2018 49 6936 Dominic Marinelli VP Accessibility Services United Spinal Association dmarinelli@accessibility
More information(n) All furniture and equipment used in any school building or a part of a building used for school purposes shall be durable and easily cleanable,
410 IAC 6-5.1-5 Physical facilities Authority: IC 16-19-3-4 Affected: IC 16-41-21 Sec. 5. (a) All school buildings or parts thereof used for school purposes shall: (1) be located, constructed, and maintained
More informationSouth Windsor Public Schools. Elementary School Facilities Existing Condition Survey & Master Plan. Executive Summary 10/22/13
South Windsor Public Schools Elementary School Facilities Executive Summary 10/22/13 SOUTH WINDSOR PUBLIC SCHOOLS ELEMENTARY SCHOOL FACILITIES EXISTING CONDITION SURVEY & MASTER PLAN EXECUTIVE SUMMARY
More informationIt is once again time to purchase your Marketing Package from Off-Campus Student Services at Texas A&M University (OCSS).
Howdy Property Managers! It is once again time to purchase your Marketing Package from Off-Campus Student Services at Texas A&M University (OCSS). Please make sure to read through everything, as most of
More informationHOUSING CONVERSION Guidelines for the conversion of a house to commercial use.
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT HOUSING CONVERSION Guidelines for the conversion of a house to commercial use. HAIR 105 January 2017 contents General Information 3 Zoning Information 4 Building
More informationIssue Agreement Code Section Source Publication / Notes
Speciman Pass-Through New Construction: Request parallel approach 48 high maximum reach range to March 2013 Code Call highest operable part. Diagonal approach is ok, allowing knees and toes to 1 encroach
More informationADA Checklist for Polling Places
U.S. Department of Justice Civil Rights Division Disability Rights Section Americans with Disabilities Act ADA Checklist for Polling Places February 2004 Reproduction Reproduction of this document is encouraged.
More informationBay Bridge Cove. Clubhouse and Ammenities QUEEN ANNE'S COUNTY, MARYLAND
Structural Engineer: APEX Technology 8 N East Street Frederick, MD 21701 Mechanical Engineer: Emerald Engineering 205 North Armenia Ave. - Suite 102 Tampa, Florida 33609 Clubhouse and Ammenities QUEEN
More informationADA Checklist for Polling Places
U.S. Department of Justice Civil Rights Division Disability Rights Section Americans with Disabilities Act ADA Checklist for Polling Places February 2004 Reproduction Reproduction of this document is encouraged.
More informationADA Checklist for Polling Places
U.S. Department of Justice Civil Rights Division Disability Rights Section Americans with Disabilities Act ADA Checklist for Polling Places February 2004 Reproduction Reproduction of this document is encouraged.
More informationNew Construction & Rehabilitation
THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2019 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS New Construction & Rehabilitation The Virginia Housing Development Authority (VHDA) recognizes
More informationADA Checklist for Existing Facilities
ADA Checklist for Existing Facilities Based on the 2010 ADA Standards for Accessible Design Produced by Institute for Human Centered Design www.humancentereddesign.org www.adachecklist.org 2014 ADA National
More informationFLORIDA DEPARTMENT OF HEALTH COUNTY HEALTH DEPARTMENT PUBLIC SCHOOL AND PUBLIC CHARTER SCHOOL INSPECTION REPORT
PURPOSE ROUTINE REINSPECTION CONSTRUCTION COMPLAINT QA SURVEY PREOPENING CHANGE OF OWNER CONSULTATION STATE OF EPIDEMIOLOGY OTHER FLORIDA DEPARTMENT OF HEALTH COUNTY HEALTH DEPARTMENT PUBLIC SCHOOL AND
More informationUniversity of Texas. Austin, TX. TAS Variance Application Guidelines For Qualifying Historic Structures
University of Texas Austin, TX TAS Variance Application Guidelines For Qualifying Historic Structures Architecture, Planning and Historic Preservation, Inc. 2900 S. Congress Ste 200 Austin, TX 78704 512.444.4220
More informationINFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS
INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit
More informationDescription Accessibility Standards. AODA OBC 2015 Ramps
Ramps OBC Ammendments are related to the following accessibility standards: The ramp must have a minimum clear width of 900 mm. The ramp must have a clear height that provides a minimum Tactile Attention
More informationMADELEY RANCH ELEMENTARY SCHOOL
MADELEY RANCH ELEMENTARY SCHOOL CAMPUS DATA MADELEY RANCH ELEMENTARY SCHOOL 3500 Madeley Ranch Road, Montgomery TX 77356 Year Built 2009 Approx. Total Square Footage Grades Served 94,750 Pre-K - 4 th
More informationChecklist for Readily Achievable Barrier Removal
CHECKLIST FOR EXISTING FACILITIES version 2.1 The Americans with Disabilities Act Checklist for Readily Achievable Barrier Removal To obtain additional copies of this checklist, contact your Disability
More informationInterior Design Legislation
Interior Design Legislation Title vs Practice Act Title Acts are laws that legislate the title of interior designer. In order to call yourself an interior designer, you may need certain requirements (varies
More informationDivision 13. Special Construction
Division 13. Special Construction 13 00 00. Special Construction General Architectural Mock Up 1. Unless there are extenuating circumstances, agreed upon during the design phase by all parties, including
More informationDOUBLE CREEK II, AUSTIN, TEXAS
PETE SKARZENSKI CONSULTING 10309 ROSSER RD. DALLAS, TEXAS 75229 MULTI-FAMILY HOUSING BUILDING CODES SPECIFICATIONS ACCESSIBILITY PRELIMINARY ACCESSIBILITY REVIEW FOR: DOUBLE CREEK II, AUSTIN, TEXAS DEVELOPER:
More information, (New), , , , 602.3, (New), (New), (New), (New), 602.4, 602.5, 602.
6-1 12 602.1, 602.2 (New), 602.2.1, 602.2.2, 602.2.2.3, 602.3, 602.3.1 (New), 602.3.2 (New), 602.3.3 (New), 602.3.4 (New), 602.4, 602.5, 602.6, Proponent: Kim Paarlberg, International Code Council 602.1
More informationFREEWILL BARRIER FREE ACRYLIC BATH AND SHOWER MODULES
FREEWILL BARRIER FREE ACRYLIC BATH AND SHOWER MODULES BEFORE YOU BEGIN PREPARATION The basin area requires no additional support when the subfloor is plumb and level with respect to the stud frame. Shim
More informationTable of Contents. April 2016 Page 1
Table of Contents Introduction...2 Purpose...2 Application...2 Definition of New Leases...3 Heritage Facilities...3 Security Considerations...3 Definition of Significant Renovation...4 Additional Items
More informationDesign Aid for Barrier-Free Accessibility in Existing Buildings
Design Aid for Barrier-Free Accessibility in Existing Buildings July 9, 2004 Table of Contents 1. Introduction 1 2. References 2 3. Access to the Building 2.1 Site Accessibility 2 4. Building Access 3.1
More informationCOLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444
COLONIAL PLANS 8US Highway Route 1 Hancock, Maine 04640 1(877)767 0664*(207)667 0664 708 North Street US Highway Route 1 Houlton, Maine 04730 (207)532,2444 DEXTER COLONIAL 28 X 34 1904 SQ. FT. DEXTER COLONIAL
More informationTenant Fit-Out for PLCB / Waynesboro Mall
Tenant Fit-Out for PLCB / CODE REVIEW: PROJECT DESCRIPTION TENANT BUILD OUT PROPOSED USE SALE OF BEVERAGE ALCOHOL / PLCB SPRINKLERED: YES ALLOWABLE BUILDING HEIGHT & AREA: GROUP M / TYPE VB ALLOWED 1 STORY
More informationNicolas Carter Matthew Hargadon Jesse Casas. SSU Toilet Report. Introduction
Nicolas Carter Matthew Hargadon Jesse Casas SSU Toilet Report Introduction Water usage is a topic that comes up frequently in the news in California, the United States, and all over the world. As a global
More informationMEMORANDUM SUMMARY OF PURPOSE PIER 33.5 RESTAURANT LEASE ASSESSMENT
MEMORANDUM To: Matthew Bell Contract: Port of San Francisco As-Needed Engineering & Related Professional Services Parsons/Lotus Water JV (PL 05) Date: September 6, 2017 From: Paul Osmundson, Premier Structures
More informationIR 11B-10 SCOPING AND PATH OF TRAVEL UPGRADE REQUIREMENTS FOR FACILITY ALTERATION, ADDITION A ND STRUCTURAL REPAIR PROJECTS
IR 11B-10 SCOPING AND PATH OF TRAVEL UPGRADE REQUIREMENTS FOR FACILITY ALTERATION, ADDITION A ND STRUCTURAL REPAIR PROJECTS Disciplines: Accessibility History: 04-27-15 Issued PURPOSE: This Interpretation
More informationDelta Gamma Sorority Renovation Budget Scope 3/7/2018
Delta Gamma Sorority Renovation Budget Scope 3/7/2018 PROJECT: Barbara Cerni Delta Gamma Sorority Tallahassee, Fla. This scope is based on the 50% Construction Documents drawn by BKJ Architecture dated
More informationWorksheet for Commercial Building Planning
Worksheet for Commercial Building Planning Note: This checklist helps ensure that all major code items were checked BEFORE applying for permit. ADDRESS OF PROJECT: Chapter 3 Information 301-312 OCCUPANCY
More information