360 Quality Code. Recommendations for Container Pre-Trip Inspections February 2015

Size: px
Start display at page:

Download "360 Quality Code. Recommendations for Container Pre-Trip Inspections February 2015"

Transcription

1 Preface These Recommendations relate to the 360 Quality Code prepared and released by the 360 Quality Association. The recommendations provide more detailed information in order to assist the specialized reefer industry. Conduct of Inspections PTI inspections are part of the supply chain of cargo in reefer containers. These inspections are executed to ensure the proper working of the reefer machinery and can differ per shipping line. The PTI inspection is valid for 30 days when the reefer container passes the inspection. In case reefer containers fail on the PTI, repairs should be executed before cargo can be carried inside the container. PTI inspections are mostly executed on terminal or depot locations. PTI companies (hereafter called service suppliers ) are responsible for an accurate execution of the PTI inspections. 1

2 1. VISUAL INSPECTION The purpose of the visual inspection is to verify if the unit is in apparent good order and condition before switching on the unit to carry out the automatic PTI test. 1.1 Are all fixing bolts present and properly tightened? The engineer checks the presence of all fixing bolts securing the reefer machinery to the container and of various panels. 1.2 Is the fresh air ventilation cover in a proper condition and not leaking? The engineer checks if leakage is present on the fresh air ventilation cover. 1.3 Is the refrigeration unit free of any damage, which can affect the proper working? The engineer checks the unit for damage or wear and tear. 1.4 Is the electrical plug and power cable in proper condition and does the cable have the minimum required length? The engineer checks if the reefer plug is undamaged and if the rubber ring and cam on the plug are present. The standard length of the cable is at least 15m (20ft container) and 18 m (40HC container). The cable should not have more than two repair splices. 1.5 Are all electrical cables properly connected? The engineer checks if all electrical cables are properly connected and that no signs of improper repairs are present. Special attention should be given to the cables in the control box. 1.6 Are all relays and contactors fitted correctly? The engineer checks if relays and contactors are correctly fitted. Switch on unit 1.7 Are evaporator and condenser fan motors free of abnormal noise? The engineer checks if abnormal noise is present (such as from fan motor bearings). In case abnormal noise is present the engineer checks if fan motors and fan blades are damaged. To check this some panels should be dismantled. 2

3 2. PREPARATIONS FOR AUTOMATIC PTI The purpose of this preparation is to verify if some components are working correctly before the automatic PTI test is initiated as otherwise the test will Fail on any of the below mentioned issues. 2.1 Are the indication-led s and display screen(s) working correctly? The engineer checks if all LED s and display screen(s) of the controller are working correctly. 2.2 Are the correct container number and date & time set in the data recorder? The engineer checks if the correct container number and date & time (UTC) is set in the data recorder. 2.3 Are all sensors & pressure transducers working correctly at ambient conditions? When the container is connected to the power supply the engineer checks if temperatures and pressure transducers indicate ambient temperature and pressure. 2.4 Is the latest software update and configuration installed according to the customers requirements? The engineer checks if the latest software is installed in the controller according to the customers requirements. 2.5 Are all default settings according to the customers demands in range? The engineer checks the in range tolerance, defrost interval and current limit requested by the particular customer. 2.6 Have all relevant modifications been carried out? The engineer checks if all relevant modifications according to manufacturers instruction (such as by a service bulletin) have been carried out. 2.7 Are spindles and protection caps of the manual service valves in good condition? The engineer checks if spindles are undamaged and free of corrosion. All spindles should have protective caps. 2.8 Is the compressor oil level sufficient? The engineer checks if the oil level of the compressor is within the range recommended by the manufacturer. 3

4 2.9 Is the condenser free of dirt? The engineer checks that less than 10% of the condenser area is dirty Are the condenser and refrigerant pipes free of oil traces? The engineer checks for the presence of oil traces on the condenser and the refrigerant pipes. Oil traces could indicate that there is a leakage in the cooling system Is the condenser fan and motor without damage or bad wiring? The engineer checks the condenser fan for damage and loose or bad wiring Is the drain hose free of obstruction or damage? The engineer checks if drops of water are present from the drain hose. In case no drops are present water has to be poured into the drain system to verify proper drainage Is the refrigerant free of moisture? The engineer checks if the indication glass indicates dry (centre is green) Is the system history free of alarms and are previously registered alarms cleared? The engineer checks the active alarms in the data recorder Is the unit free of abnormal noises? The engineer checks for the presence of abnormal noises from the complete reefer unit. Set unit temperature set point at 0 o C 2.16 Are all sensors & pressure transducers working correctly at 0 o C? The engineer checks if temperature sensors and pressure transducers indicate the temperatures and pressures present in the container. Temperatures should be in line with each other Is there sufficient airflow from the reefer unit inside the container? The engineer checks the presence of sufficient airflow and that the baffle plate is in correct position inside the container Are the container drains clear and can they be closed? The engineer checks proper functioning of the container drains Are the partial cool functions at 0 o C working correctly? 4

5 The engineer checks that the partial cool functions and capacity control (modulation, unloading, hot gas and/or bypass) are working correctly and temperature settings are maintained Is a megger test executed on compressor, condenser fan motor, evaporator fan (high & low speed), heater rods and is resistance minimum 0.5 MOhm? The engineer checks the resistance of the above mentioned components against earth. Initiate an automatic PTI test. 3. RESULT OF AUTOMATIC PTI 3.1 Does the container pass the requested PTI test? The engineer checks if the reefer container passes the PTI test according to customer requirements. 3.2 Are drip pan and refrigerant pipes free of oil traces after running the PTI? The engineer checks if drip pan is clean and if no oil traces are present on refrigerant pipes. 3.3 Is the system free of any active or inactive alarms? The engineer checks if alarms have become active in the controller of the reefer container. Set unit temperature set point at -20 o C 3.4 Are all sensors & pressure transducers working correctly at -20 o C? The engineer checks if temperatures and pressure transducers indicate the temperatures and pressure present in the container. Temperature sensor indications should be in line with each other. 3.5 Is the level of the refrigerant sufficient at -20 o C (full capacity)? The engineer checks the level of refrigerant when temperature is in range, compressor is running and condenser fan is switched off. 5

6 Attachment No.1 Carrier Transicold Pre-trip diagnosis provides automatic testing of the unit components using internal measurements and comparison logic. The program will provide a PASS or FAIL display to indicate test results. The testing begins with access to a Pre-Trip selection menu. The user may have the option of selecting one of two automatic tests. These tests will automatically perform a series of individual Pre-trip tests. The user may also scroll down to select any of the individual tests. When the short sequence is configured, it will appear as AUTO in the display. AUTO1 (Short PTI) will also indicate the short sequence and run tests P0 through P6. AUTO2 will indicate the long sequence and run tests P0 through P10, while AUTO3 is a mid-sequence (Perishable PTI) and run tests P0 through P8. Full description of each "P" test can be found in appendix 1. Thermo King Brief PTI pre-trip test (short PTI) automatically checks unit refrigeration capacity, heating capacity, temperature control, and individual components including the controller display, contactors, fans, protection devices and sensors. The test includes measurement of component power consumption and compares test results to expected values. Function Test automatically tests individual components including the controller display, sensors, condenser fan, evaporator fan, compressors, etc. The test includes measurement of component power consumption and compares test results to expected values. Full PTI (Long PTI) is a special Full PTI pre-trip test that automatically checks unit refrigeration capacity, heating capacity, temperature control, and individual components including the controller display, contactors, fans, protection devices and sensors. The test includes measurement of component power consumption and compares test results to expected values. StarCool StarCool has a Function test, PTI (Pre-Trip Inspection/ Long PTI) test and a PTI short (optional/ perishable PTI ). Function test (short PTI) is a unit component test. The test is based on a GO/NO GO procedure. All tests must be executed without failure one by one for the function test result to PASS. Function test includes the following items: 1. PTI init 2. Controller test 3. Power check 4. Evaporator fan (Mevap) 5. Condenser fan (Mcond) 6. Heating element (Hevap) 6

7 7. Probe check. 8. Compressor/FC/valve test (Vexpansion, Vhotgas and Veconomizer) PTI (Pre-Trip Inspection/ Long PTI) test. The purpose of the PTI test is to verify the presence of cooling performance. The test is based on a GO/NO GO procedure. All tests must be executed without failure one by one for the PTI result to PASS. 1. Function test (see Function test) 2. 5 C (41 F) test 3. 0 C (32 F) test C (-0.4 F) test 5. Defrosting 6. Test completion / status PTI short (optional/ perishable PTI ) Short PTI includes the following test items: 1. Function test 2. 5 C (41 F) test 3. 0 C (32 F) test 4. Defrosting 5. Test completion / status Daikin For S-PTI (Short PTI) the components are inspected for abnormalities. Even if any abnormal components are found, all processes are executed. F-PTI (long PTI) is an S-PTI + a test of the unit cooling capacity. The cooling capacity check is executed only if any abnormal components are not found with S-PTI. If any abnormality is found during the cooling capacity inspection, F-PTI is terminated. Test results of PTI inspections are archived in the data recorder. Downloads can be taken from the container to track history results, including temperature results during voyages. The shipping line has to inform their service suppliers which of the above tests should be implemented in the PTI procedure. 7

Daikin LXE10E Reefer Machine

Daikin LXE10E Reefer Machine Daikin LXE10E Reefer Machine Carry your temperature-controlled container cargo confident in the knowledge it is receiving the ultimate care and attention from a Daikin machine. Quality Performance Reliability

More information

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER 1. Preface OPERATIONS AND MAINTAINENCE MANUAL 1-800-444-8693 Operation and Maintenance Manual For Amcot LRC-H Cooling Tower & LRC-LNS

More information

Daikin LXE10E Reefer Machine The industry s bestselling scroll reefer unit

Daikin LXE10E Reefer Machine The industry s bestselling scroll reefer unit Daikin LXE10E Reefer Machine The industry s bestselling scroll reefer unit Quality Performance Reliability Daikin consistently delivers all three essential ingredients for the transportation of your refrigerated

More information

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw YKN2open Features High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating +

More information

- 1 - InfraStruXure InRow SC Assembly and Start-Up. Installation Service

- 1 - InfraStruXure InRow SC Assembly and Start-Up. Installation Service Installation Service - 1 - InfraStruXure InRow SC Assembly and Start-Up Statement of Work 1.0 Executive Summary InfraStruXure InRow SC Assembly & Start-Up Service Table of Contents 1.0 Executive Summary

More information

msc.com/reefer INTERNATIONAL REEFER CARGO SERVICES

msc.com/reefer INTERNATIONAL REEFER CARGO SERVICES msc.com/reefer INTERNATIONAL REEFER CARGO SERVICES TABLE OF CONTENTS REEFER CARGO SERVICES 5 6 10 16 18 A FAMILY COMPANY CARING FOR YOUR BUSINESS RELY ON OUR EXPERTS FOR YOUR CARGO CARING FOR YOUR CARGO

More information

HYDROCARBON REFRIGERANT CONVERSION REPORT FOR CITIBANK HOUSE 37 ST. GEORGES TERRACE PERTH, W.A.

HYDROCARBON REFRIGERANT CONVERSION REPORT FOR CITIBANK HOUSE 37 ST. GEORGES TERRACE PERTH, W.A. HYDROCARBON REFRIGERANT CONVERSION REPORT FOR CITIBANK HOUSE 37 ST. GEORGES TERRACE PERTH, W.A. Prepared by: MR SELWYN WALLACE ENGAS AUSTRALASIA DR LADAS TAYLOR ENGAS AUSTRALASIA INITIAL INSPECTION OF

More information

Identify and Quantify Mission-Critical Factors (How to Perform a Critical Audit) Neil Maldeis, Energy Solutions Engineering Leader, Trane

Identify and Quantify Mission-Critical Factors (How to Perform a Critical Audit) Neil Maldeis, Energy Solutions Engineering Leader, Trane Identify and Quantify Mission-Critical Factors (How to Perform a Critical Audit) Neil Maldeis, Energy Solutions Engineering Leader, Trane Learning Objectives Benefits of a critical system audit How to

More information

MAGNUM PLUS. Container refrigeration. Fresh or frozen: faster is better.

MAGNUM PLUS. Container refrigeration. Fresh or frozen: faster is better. MAGNUM PLUS Container refrigeration. Fresh or frozen: faster is better. Premium performance. No compromise. Premium performance. No compromise. Thermo King is committed to engineering innovative products

More information

About Hot Gas Defrost. Hot Gas Defrost Benefits

About Hot Gas Defrost. Hot Gas Defrost Benefits About Hot Gas Defrost Hot gas defrost is the energy-efficient alternative to electric defrost refrigeration systems. Hot gas defrost systems work by routing hot compressor discharge gas through the outlet

More information

Table of contents. 1. Introduction

Table of contents. 1. Introduction 2 Year Warranty Table of contents 1. Introduction 1-1. Transportation 1-2. Preliminary steps 1-3. Initial setup 1-4. Important safety instructions 1-5. Maintenance, service and faults 2. Operation 2.1

More information

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 23 81 00 DECENTRALIZED HVAC EQUIPMENT A. The other Contract Documents complement the requirements of this section. The General requirements apply to the work

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

YKN2open A R C 032 A B

YKN2open A R C 032 A B york air-conditioning products ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 17 kw up to 40 kw YKN2open Features High efficiency EER and COP Low noise level EC supply fan All configurations: Cooling

More information

Rebel commercial packaged rooftop systems

Rebel commercial packaged rooftop systems Rebel commercial packaged rooftop systems Advanced technologies propel performance and energy savings to uncommon levels 3-28 tons Rebel features and benefits 18 13 6 5 3 6 4 43% Energy Savings 5 11 12

More information

Rebel commercial packaged rooftop systems

Rebel commercial packaged rooftop systems Rebel commercial packaged rooftop systems Advanced technologies propel performance and energy savings to uncommon levels 3-28 tons Capitalize with 43% more energy savings If you are a commercial building

More information

MODEL INSTALLATION INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR Supplier Checklist WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR The following checklist provides guidance on which information to collect from within the winery and from the equipment

More information

T-Series. An all-new line of self-powered truck units destined to become the new industry benchmark.

T-Series. An all-new line of self-powered truck units destined to become the new industry benchmark. T-Series An all-new line of self-powered truck units destined to become the new industry benchmark. Welcome to the all-new T-Series Delivering what matters. They re here. After years of engineering research

More information

Farm Energy IQ. Farms Today Securing Our Energy Future

Farm Energy IQ. Farms Today Securing Our Energy Future Farm Energy IQ Farms Today Securing Our Energy Future Farm Energy IQ Ryan Hilton, Daniel Ciolkosz, and Tara Baugher Penn State Extension Preview: PART 1: Energy Use on Tree Fruit Farms PART 2: Opportunities

More information

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ REFRIGERANT CONDENSERS Guide Specifications T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ September 5, 2012 Note: This Specification is for Allied Commercial T-Series 6- to 20-ton, outdoor air conditioner

More information

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

All applicable equipment trip settings must be checked and recorded on the appropriate record sheet.

All applicable equipment trip settings must be checked and recorded on the appropriate record sheet. EXHEAT Electric Heaters and Control Systems Instructions for Completion and Submission of Commissioning Records and Associated Start-up Certificate. It is the responsibility of the installer and end user

More information

Level 3 Refrigeration and Air Conditioning CPD Pathways ( ) Candidate performance evidence logbook

Level 3 Refrigeration and Air Conditioning CPD Pathways ( ) Candidate performance evidence logbook Level 3 Refrigeration and Air Conditioning CPD Pathways (6187-31) Candidate performance evidence logbook www.cityandguilds.com February 2012 Version 1.0 About City & Guilds As the UK s leading vocational

More information

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems Presenter: Ramin Faramarzi, P.E., Principal Engineer, National Renewable Energy Lab Acknowledgement

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

WHITE PAPER The Criticality of Proactive Maintenance on Isolated Phase Bus Duct Systems

WHITE PAPER The Criticality of Proactive Maintenance on Isolated Phase Bus Duct Systems WHITE PAPER The Criticality of Proactive Maintenance on Isolated Phase Bus Duct Systems Introduction Isolated Phase Bus Duct (IPBD) is the main conduit for power distribution in a power generation facility.

More information

DETAILED PROCEDURE AND GUIDELINES TEMPERATURE MAPPING STUDY & QUALIFICATION OF COLD ROOMS, WAREHOUSES, VANS, TRUCKS, REEFERS, REFRIGERATORS & BOXES

DETAILED PROCEDURE AND GUIDELINES TEMPERATURE MAPPING STUDY & QUALIFICATION OF COLD ROOMS, WAREHOUSES, VANS, TRUCKS, REEFERS, REFRIGERATORS & BOXES DETAILED PROCEDURE AND GUIDELINES ON TEMPERATURE MAPPING STUDY & QUALIFICATION OF COLD ROOMS, WAREHOUSES, VANS, TRUCKS, REEFERS, REFRIGERATORS & BOXES FOR PHARMACEUTICAL INDUSTRY Revision History: Revision

More information

DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES

DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES Test Procedure for DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES TxDOT Designation: Tex-212-F Effective Date: March 2016 1. SCOPE 1.1 Use this test method to determine the moisture content of any

More information

SB-210+ The new benchmark in temperature control continues the SB tradition.

SB-210+ The new benchmark in temperature control continues the SB tradition. SB-210+ The new benchmark in temperature control continues the SB tradition. Welcome to the new SB-210+ Introducing the latest chapter in the SB tradition Today s trucking environment is a tough one, with

More information

Largo & Allegro. Air Compressors. Largo & Allegro

Largo & Allegro. Air Compressors. Largo & Allegro Largo & Allegro Air Compressors Largo 110-160 & Allegro 110-180 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer

More information

Centrifugal Air Compressors. MSG Centac C-Series 350-1,300 kw (500-1,750 hp)

Centrifugal Air Compressors. MSG Centac C-Series 350-1,300 kw (500-1,750 hp) Centrifugal Air Compressors MSG Centac C-Series 350-1,300 kw (500-1,750 hp) A Tradition of Proven Reliability, Efficiency and Productivity Over 100 years of Oil-Free Innovation With our new line of oil-free

More information

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased: OPERATION MANUAL A220 Arc Welding Machine Serial Number: Where Purchase: Date of purchased: CONTENT 1.Safety... 2 2. Summary... 4 3. Electrical principle drawing... 5 4. Specifications... 6 5. Operation

More information

Meet the new T-80 Series

Meet the new T-80 Series T-80 Series A complete line of self-powered truck units that deliver a lower cost of ownership through lower maintenance costs, improved fuel economy and unmatched reliability. Meet the new T-80 Series

More information

Attachment 1: RAE Corporation Technical Specification

Attachment 1: RAE Corporation Technical Specification Attachment 1: RAE Corporation Technical Specification RAE Corporation Phone: 918-825-7222, ext. 105 Steve Corbin Quote# XXXX Qty Customer Tag Technical Systems Model Number 1 ACC-4 10A0-162-S General Scope

More information

MODEL INSTALLATION INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED EVERY ITEM WILL BE REVIEWED AND NOTED FOR COMPLIANCE (C), OR NON- APPLICABILITY (NA). 1. HEATING SYSTEMS: A. GENERAL

More information

QUICKTEMP TECHNOLOGY IMPROVED EFFICIENCY ACROSS THE ENTIRE T-80 RANGE OF UNITS

QUICKTEMP TECHNOLOGY IMPROVED EFFICIENCY ACROSS THE ENTIRE T-80 RANGE OF UNITS T-80 Series A complete line of self-powered truck units that deliver a lower cost of ownership through lower maintenance costs, improved fuel economy and unmatched reliability. MEET THE T-80 SERIES In

More information

SPECTRUM SB Multi-Temperature System. Now with the easy-to-use SR-2 (Smart Reefer 2 ) controller.

SPECTRUM SB Multi-Temperature System. Now with the easy-to-use SR-2 (Smart Reefer 2 ) controller. SPECTRUM SB Multi-Temperature System Now with the easy-to-use SR-2 (Smart Reefer 2 ) controller. Spectrum SB multi-temperature systems lead the way in advanced cargo protection. SPECTRUM Features: High

More information

MSG Centac Centrifugal Air Compressors

MSG Centac Centrifugal Air Compressors MSG Centac Centrifugal Air Compressors 175-6,000 hp (130-4,500 kw) IngersollRandProducts.com 1 A Tradition of Proven Reliability, fficiency and Productivity Over 100 years of Oil-Free Innovation We introduced

More information

HTC steam turbine front radial bearing high temperature issue

HTC steam turbine front radial bearing high temperature issue HTC steam turbine front radial bearing high temperature issue HTC steam turbine type : T7635 condensation Turbine parameter: Rated RPM:6042, Rated power:32000kw. Design steam pressure : 8.935Mpa Design

More information

DOMESTIC HOT WATER UNIT

DOMESTIC HOT WATER UNIT DOMESTIC HOT WATER UNIT S T A T U S : H e a t i n g O u t l e t w a t e r t e m p. 3 1 T a r g e t t e m p. 5 7 2 4 0 6 2 0 1 1 0 9 : 2 8 CONTENT 1.Preface... 1 2.Specification... 3 1). Technical Data......

More information

SB-110+ The new benchmark in temperature control continues the SB tradition.

SB-110+ The new benchmark in temperature control continues the SB tradition. SB-110+ The new benchmark in temperature control continues the SB tradition. Welcome to the new SB-110+ Introducing the latest chapter in the SB tradition Today s trucking environment is a tough one, with

More information

MODELS PH PH PH

MODELS PH PH PH WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

CarrierTransicold, as well as agent for Daikin,Thermo-King,Starcool and MHI.

CarrierTransicold, as well as agent for Daikin,Thermo-King,Starcool and MHI. Sales, rental and leasing of refurbished refrigerated container o for domestic storage and transportation of perishables, o agriculture produces and frozen products, including general o purpose cargo container.

More information

Apprenticeship Curriculum Standard. Level 2 Intermediate. Trade Code: 313D

Apprenticeship Curriculum Standard. Level 2 Intermediate. Trade Code: 313D Apprenticeship Curriculum Standard Residential Air Conditioning Systems Mechanic Branch 2 Intermediate Trade Code: 313D Date: 2008 Please Note: Apprenticeship Training and Curriculum Standards were developed

More information

SUMMARY 1234 Main St.Hamilton Ohio Buyer Name 07/03/2018 9:00AM

SUMMARY 1234 Main St.Hamilton Ohio Buyer Name 07/03/2018 9:00AM SUMMARY 1234 Main St.Hamilton Ohio 45013 Buyer Name 07/03/2018 9:00AM Todd Engle,CMI Certified Master Inspector Good Eye Home Inspections 859-630-4659 toddthehomeinspector@gmail.com Client information:

More information

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

PIP PCEPA003 Process Analyzer System Field Installation Guidelines January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,

More information

Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539

Instruction manual AS 300 CG. Waste water filtration unit. Im Geer 20, D Isselburg. Descriptioin / Type-No.: AS 300 CG Typ 539 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Descriptioin / Type-No.: Typ 539 Table of contents on page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

INSTALLATION INSTRUCTIONS MODEL THE CONTRACTOR SUMP BUDDY

INSTALLATION INSTRUCTIONS MODEL THE CONTRACTOR SUMP BUDDY www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

ROOF TOP PACKAGE UNITS

ROOF TOP PACKAGE UNITS ROOF TOP PACKAGE UNITS Inverter compressors, EC fans, double skin construction package units designed to suit your project requirements SMART PACKAGE UNITS Delivering an extensive range, with capacities

More information

Rooftops High performance, proven reliability and easy installation

Rooftops High performance, proven reliability and easy installation Rooftops High performance, proven reliability and easy installation 1 Airfinity Rooftops Comfort and economy When it comes to installing and maintaining an HVAC system, every cent counts. From your initial

More information

Air Conditioning How to keep it working. Bill Desrosiers, HSB

Air Conditioning How to keep it working. Bill Desrosiers, HSB Air Conditioning How to keep it working Bill Desrosiers, HSB William_Desrosiers@hsb.com 1-860-722-5546 Basic Maintenance Why Do We Care? Proper maintenance reduces overall costs Basic Maintenance Why Do

More information

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group

VRF V4+K Series 50Hz. Commercial Air Conditioners Commercial Air Conditioner Division Midea Group Coercial Air Conditioners 2016 Coercial Air Conditioner Division Midea Group VRF V4+K Series 50Hz Midea CAC After-service Application Midea CAC News Application Add.: West Region of Midea Coercial Air

More information

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP Model T00718 REPAIR PARTS REF. PART DESCRIPTION 1 310883 Upper casing 2 310885 Motor housing 3 310889 Stator 4 310887 Shaft / rotor 5 310895 Mechanical seal 6 310892 Impeller 7 310893 Strainer 8 310890

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION SERIES 20 J**YC/YD 90000 To 300000 BTU S SPLIT SYSTEM CONDENSING UNITS 7.5 To 25 TON START-UP CHECKLIST Date: _ Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial

More information

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

2200-Lb. Semi-Electric Stacker OWNER S MANUAL 2200-Lb. Semi-Electric Stacker OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

SECTION COOLING TOWER

SECTION COOLING TOWER PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue

More information

Voyager kw rooftop units Plug and Play comfort in commercial applications

Voyager kw rooftop units Plug and Play comfort in commercial applications Voyager 17-165 kw rooftop units Plug and Play comfort in commercial applications Top efficiency, flexibility, reliability Eurovent certification for the Voyager range guarantees accurate performance data

More information

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER MODEL KD-90D INSTRUCTION MANUAL IMPORTANT 1. This booklet is an integral and essential part of the product and should

More information

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V Rollair Air Compressors ROLLAIR 150E-150-180-220 AND ROLLAIR 150V-180V-240V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial

More information

Integrated Air Conditioning System

Integrated Air Conditioning System Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability

More information

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15 ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15 ir Cooled Scroll Chiller ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum

More information

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A. FAST POWER FACTOR REGULATOR Computer-14df - xx - 144a INSTRUCTION MANUAL ( M 981 611 / 00A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14f --------- Page 2 POWER FACTOR REGULATOR COMPUTER-

More information

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. PAGE 1 of 5 1.1. REFERENCE STANDARDS 1.1.1. The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. 1.1.2. Unit shall be designed to conform to ASHRAE 15. 1.1.3. Unit

More information

RULES PUBLICATION NO. 95/P SURVEY REQUIREMENTS FOR SHELL AND INNER DOORS OF RO-RO SHIPS

RULES PUBLICATION NO. 95/P SURVEY REQUIREMENTS FOR SHELL AND INNER DOORS OF RO-RO SHIPS RULES PUBLICATION NO. 95/P SURVEY REQUIREMENTS FOR SHELL AND INNER DOORS OF RO-RO SHIPS 2012 Publications P (Additional Rule Requirements) issued by Polski Rejestr Statków complete or extend the Rules

More information

Buckingham-PJT SVC Training

Buckingham-PJT SVC Training Buckingham-PJT SVC Training Contents 1. Introduction of Buckingham 2. Installation 3. Problems about dispenser door temperature noise installation lights self diagnosis LG Electronics / Digital Appliance

More information

Capital Projects Group Air Terminal Units Specification

Capital Projects Group Air Terminal Units Specification Capital Projects Group Air Terminal Units Specification Specification 23 36 00 Revision 0 Date: August 2018 Air Terminal Units Specification Specification 23 36 00 Publication Date: August 2018 COPYRIGHT

More information

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Packaged reciprocating gas compressors

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Packaged reciprocating gas compressors INTERNATIONAL STANDARD ISO 13631 First edition 2002-08-01 Petroleum and natural gas industries Packaged reciprocating gas compressors Industries du pétrole et du gaz naturel Unités de compresseurs alternatifs

More information

Sound HVAC Choices for Sustainable Design. Julian de Bullet

Sound HVAC Choices for Sustainable Design. Julian de Bullet PLEASE MUTE CELL PHONES Sound HVAC Choices for Sustainable Design Julian de Bullet Director of Industry Relations McQuay International ASHRAE Distinguished Lecturer 703-395-5054 1 2 Rising?? What Is Sustainability?

More information

VRF 50/60Hz V5 E Series

VRF 50/60Hz V5 E Series 1702-1V1701 VRF 50/60Hz V5 E Series Coercial Air Conditioners 2017/2018 VRF 50/60Hz V5 E Series Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde,

More information

Inside This Issue. TechFact: PrimeLINE ONE Container

Inside This Issue. TechFact: PrimeLINE ONE Container A EXCHAGE OF TECHICAL IFORMATIO VOLUME 24 UMBER 2 ABOUT CARRIER TRASICOLD COTAIER PRODUCTS ov 2018 Inside This Issue TechFact / TechTip PrimeLIE OE Container Genset Battery Charger aturalie CO2 Refrigerant

More information

INVERTER ROOF TOP PACKAGE UNITS

INVERTER ROOF TOP PACKAGE UNITS INVERTER ROOF TOP PACKAGE UNITS SMART PACKAGE UNITS Delivering an extensive range, with capacities starting from 11kW up to 270kW, incorporating inverter technology throughout our roof top package units.

More information

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 CO-GENERTATION POWER PLANT CONCEPT For dimensioning, design

More information

NZQA registered unit standard 3846 version 7 Page 1 of 7. Maintain commercial refrigeration and/or air conditioning systems

NZQA registered unit standard 3846 version 7 Page 1 of 7. Maintain commercial refrigeration and/or air conditioning systems Page 1 of 7 Title Maintain commercial refrigeration and/or air conditioning systems Level 3 Credits 20 Purpose This unit standard is for people who work in the refrigeration and air conditioning sector

More information

SECTION AIR COILS

SECTION AIR COILS SECTION 23 82 16 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two Marine/Industrial Single Package Design Series One, Beginning Serial Number C96741 & Design Series Two 62-10404 -01 PARTS LIST Service Parts List SINGLE PACKAGE COOLING UNIT Design Series One, Beginning

More information

SECTION FUEL-FIRED UNIT HEATERS

SECTION FUEL-FIRED UNIT HEATERS SECTION 23 55 33 PART 1 - GENERAL 1.1 DESCRIPTION A. This Section includes gas-fired unit heaters. SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 13-6609-6610 Ground Test Tool Boeing 787 Ram Air Turbine 10/2009 Rev. 01 Includes Illustrated Parts Lists DEVELOPED IN CONJUNCTION WITH HAMILTON-SUNDSTRAND 1740 Eber Rd

More information

EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS

EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS EXHIBIT A SCOPE OF SERVICES MAINTENANCE OF TRANE HVAC SYSTEMS DISTRICT VII, HEADQUARTERS FACILITY AND TAMPA BAY SUNGUIDE REGIONAL TRAFFIC MANAGEMENT CENTER I. PURPOSE: DISTRICT VII, HEADQUARTERS FACILITY

More information

NaturaLINE. In making history, we ve created the future.

NaturaLINE. In making history, we ve created the future. NaturaLINE In making history, we ve created the future. The Natural One For container shipping, CO 2 is the only refrigerant that meets all of the following criteria: Natural Leadership Carrier has been

More information

McQuay. Air Cooled Condensing Unit. ALP Vintage D. Last Manufactured: Replacement Parts List No Revision E 09/2016

McQuay. Air Cooled Condensing Unit. ALP Vintage D. Last Manufactured: Replacement Parts List No Revision E 09/2016 Replacement Parts List No. 057115300 Revision E 09/2016 McQuay Air Cooled Condensing Unit ALP 012-019 Vintage D Last Manufactured: 2002 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

B. OPR, BoD, and BoD-HVAC documentation prepared by Owner and Architect contains requirements that apply to this Section.

B. OPR, BoD, and BoD-HVAC documentation prepared by Owner and Architect contains requirements that apply to this Section. SECTION 01815 - HVAC COMMISSIONING REQUIREMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

CARRIAGE OF INTEGRAL REFRIGERATED CONTAINERS ON BOARD SHIPS

CARRIAGE OF INTEGRAL REFRIGERATED CONTAINERS ON BOARD SHIPS Guide for Carriage of Integral Refrigerated Containers on Board Ships GUIDE FOR CARRIAGE OF INTEGRAL REFRIGERATED CONTAINERS ON BOARD SHIPS MAY 2017 American Bureau of Shipping Incorporated by Act of Legislature

More information

TABLE OF CONTENTS. Cordless Impact Wrench. Model No. EYFPA1J. Europe

TABLE OF CONTENTS. Cordless Impact Wrench. Model No. EYFPA1J. Europe Order Number PTD1512E07CE Cordless Impact Wrench Model No. EYFPA1J Europe TABLE OF CONTENTS PAGE 1 Warning-------------------------------------------------------------- 2 2 Specifications -----------------------------------------------------

More information

Carry out general service checks on non-electric forklifts and forklift attachments

Carry out general service checks on non-electric forklifts and forklift attachments Page 1 of 5 Carry out general service checks on non-electric forklifts and forklift attachments Level 3 Credits 4 Purpose This unit standard is for people in the materials handling equipment repair industry.

More information

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used

More information

Guideline for In-Service Assessment of Ammonia Refrigeration Plants

Guideline for In-Service Assessment of Ammonia Refrigeration Plants Guideline for In-Service Assessment of Ammonia Refrigeration Plants This communication is intended to be used by plant owners and operators to provide guidance in preparation for an assessment of the plant

More information

Energy efficiency of cooling systems: Optimization through precise energy monitoring

Energy efficiency of cooling systems: Optimization through precise energy monitoring Bilfinger Efficiency GmbH Energy efficiency of cooling systems: Optimization through precise energy monitoring Thomas Theiner ACHEMA 2015, Frankfurt am Main June 15-19, 2015 On the way to new efficiency

More information

REFCON 6 The safest way to transport refrigerated cargo

REFCON 6 The safest way to transport refrigerated cargo REFCON 6 The safest way to transport refrigerated cargo GLOBAL MONITORING SERVER REEFER MONITORING SYSTEM Stay cool all the way Perfect control of reefer containers and cargo. Always! REFCON 6 is the next-generation

More information

Fall MERCER COUNTY COMMUNITY COLLEGE Business Technology Division. Course Outline. Heavy Commercial Systems I. HRA 205 Course Number

Fall MERCER COUNTY COMMUNITY COLLEGE Business Technology Division. Course Outline. Heavy Commercial Systems I. HRA 205 Course Number Fall 2017 MERCER COUNTY COMMUNITY COLLEGE Business Technology Division Course Outline HRA 205 Course Number Heavy Commercial Systems I Credits 4 Class Hours 3 Laboratory Hours 3 TEXT: Refrigeration & Air

More information

FRESH OR FROZEN. FASTER IS BETTER.

FRESH OR FROZEN. FASTER IS BETTER. FRESH OR FROZEN. FASTER IS BETTER. 3 PREMIUM PERFORMANCE. NO COMPROMISE. PREMIUM PERFORMANCE. NO COMPROMISE. Thermo King is committed to engineering innovative products and technologies to provide ever-increasing

More information

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI

OPERATING INSTRUCTIONs ISTRUZIONI D USO. MODE d EMPLOI OPERATING INSTRUCTIONs ISTRUZIONI D USO MODE d EMPLOI EN IT FR Control panel for air to water Inverter heat pump Pannello di controllo per pompa di calore Inverter aria / acqua Panneau de contrôle pour

More information

EFFECTIVE STRATEGIES FOR RAGAGEP APPLICATION HOW TO MEET RAGAGEP COMPLIANCE FOR PSM & RMP SUMMARY

EFFECTIVE STRATEGIES FOR RAGAGEP APPLICATION HOW TO MEET RAGAGEP COMPLIANCE FOR PSM & RMP SUMMARY EFFECTIVE STRATEGIES FOR RAGAGEP APPLICATION HOW TO MEET RAGAGEP COMPLIANCE FOR PSM & RMP Stephanie Smith, PE Risk Management Professionals (949) 282-0123 (877) 532-0806 SUMMARY What is RAGAGEP? Sources

More information

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL : 514.337.4415 LAVAL (QUEBEC) FAX : 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during

More information