INSTALLATION INSTRUCTIONS

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS"

Transcription

1 0 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS MPA, MPB and MLA MULTI-ZONE OUTDOOR UNITS MULTI-ZONE MINI-SPLIT OUTDOOR UNITS (08/0V) /0 Supersedes Table of Contents General... Included Parts... Compatible s... Number Identification... Typical Multi-Zone System Components... Unit Dimensions... Unit Clearances... Torque Requirements for Caps and Fasteners... Unit Installation... Placement Considerations... Direct Sunlight, Rain, Snow and Ice Protection... Prevailing Winds... Buried Refrigerant Pipe Protection...7 Unit Condensate Piping...7 Securing the Unit...7 Refrigerant Piping Connections...8 Installation...9 Connecting Multiple s...9 Indoor / Unit Match-Ups... Leak Test and Evacuation...7 Leak Test...7 Triple Evacuation Procedure...7 Wiring Connections...7 Unit...7 s...7 Unit Start-Up... Refrigerant Charge... WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. THIS MANUAL MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, ser vice or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a li censed professional HVAC installer (or equivalent) or a service agency. WARNING The clean Air Act of 990 bans the intentional venting of refrigerant (CFCs, HCFCs, and HFCs) as of July, 99. Approved methods of recovery, recycling or reclaiming must be followed. Fines and/or incarceration may be levied for non-compliance. CAUTION As with any mechanical equipment, contact with sharp sheet metal edges can result in personal injury. Take care while handling this equipment and wear gloves and protective clothing. General Refer to the Product Specifications bulletin (EHB) for more product information. These instructions are intended as a general guide and do not supersede local or national codes in any way. Authorities having jurisdiction should be consulted before installation. The MWMA, MWMB, MA, MA, MB, MMDA, MCFA and MCFB indoor units are matched with a two to five port multi-zone outdoor heat pump unit to create a mini-split system that uses HFC-0A refrigerant.

2 Included Parts Check the components for shipping damage. If you find any damage, immediately contact the last carrier. Package contains the following: - Assembled (The assembled indoor unit will include accessories specific to the unit, see each indoor unit s section within this manual for accessories included with that unit.) - Assembled Unit and the following items: Parts Figure Qty Parts Figure Qty Parts Figure Qty Drain connector Installation and owner s manual ea. Seal Ring Adapters MPA08SM-*P MPB08SM-*P MLA08SM-*P adapt. /8 to / MPA00SM-*P MPB00SM-*P MLA00SM-*P adapt. /8 to / MPA0SM-*P MPB0SM-*P MLA0SM-*P adapt. /8 to / adapt. / to /8 MPA08SM-*P MPB08SM-*P adapt. /8 to / adapt. / to /8 Compatible s Voltage Voltage MWMA009S-*P 08/0V MA0S-*P 08/0V MWMA0S-*P 08/0V MMDA009S-*P 08/0V MWMA08S-*P 08/0V MMDA0S-*P 08/0V MWMA0S-*P 08/0V MMDA08S-*P 08/0V MA009S-*P 08/0V MMDA0S-*P 08/0V MA0S-*P 08/0V MCFB08S-*P 08/0V MA08S-*P 08/0V MCFA0S-*P 08/0V The,000 Btu indoor unit is only allowed to be connected to MPA08SM, MPB08SM and MLA0SM multi-zone outdoor units. Only second generation (-P) indoor units will work with MLA multi-zone outdoor units. Number Identification M P A 08 S M - P Series Type M = Mini-Split Unit Type L = Low Ambient Heat Pump P = Heat Pump Major Design Sequence A = st Generation B = nd Generation Nominal Cooling 08 =. ton 00 =. tons 0 = tons 08 = tons Refrigerant Circuits M = Multiple Circuits Refrigerant Type = HFC-0A Cooling Efficiency S = Standard Efficiency Voltage P = 08/0V- phase-0hz Minor Design Sequence = st Revision

3 Typical Multi-Zone System Components IMPORTANT - Condensate drain line must always be located at the bottom of the bundle.) Line set (wrapped in foam insulation) Wiring TAPE Condensate drain line (wrapped in foam insulation) Refrigerant, Condensate Line And Indoor / Cable (field-provided) Return Air Filter IMPORTANT - The refrigerant metering device for this system is located in the outdoor unit. This makes it necessary to insulate the refrigerant lines individually to prevent sweating. Supply Air UV-rated tape (field-provided) Indoor unit wiring connections (under access plate) MWMA009 Shown Up to ports depending on outdoor unit model Indoor unit type may vary Utility Bundle One per indoor unit MPA08SM Shown Unit Appearance May Vary by Access cover for power and control wiring connections See Unit wiring diagram for individual system wiring. 08/0V Unit Terminal Block L L Up to ports depending on outdoor unit model Port E Liquid line shut off valve line shut off valve Port D Liquid line shut off valve line shut off valve Port C Liquid line shut off valve line shut off valve Port B Liquid line shut off valve line shut off valve Condensate drain line (field-provided, one per indoor unit) Access cover for service valves MPA08SM shown Port A Liquid line shut off valve line shut off valve Liquid and vapor line service and shut off valves Figure. Typical System Shown

4 Unit Dimensions C D E B A TYPICAL APPEARANCE OF UNITS MPA08SM-*P MPA00SM-*P MPA0SM-*P MPA08SM-*P Unit of Measurement A B C D E inches -/ 7-/8 -/ -/8 mm inches 7-/ -/ -7/8 -/ mm inches -7/8-7/8 -/ -/8 mm MPB08SM-*P MPB00SM-*P MPB0SM-*P MPB08SM-*P MLA08SM-*P MLA00SM-*P MLA0SM-*P inches -/ 7-/8 -/ -/ mm inches 0-/ -/ -7/8 -/8-7/8 mm inches -/ -/ -/8-7/8 mm 00 0 inches 0-/8 -/ -7/8 -/8-7/8 mm inches -/8 -/ -/8-7/8 mm Figure. Unit Dimensions - Inches (mm) Unit Clearances (0) Air Inlet (0) (0) (0) 79 (007) Air Outlet Minimum rear clearance can be inches ( mm) when mounted on brackets and with no obstructions on the other three sides. Figure. Unit Clearances - Inches (mm)

5 Torque Requirements for Caps and Fasteners When servicing or repairing HVAC components, ensure the fasteners are appropriately tightened. Table. Torque Requirements provides torque values for fasteners. IMPORTANT Only use Allen wrenches of sufficient hardness (0Rc - Rockwell scale minimum). Fully insert the wrench into the valve stem recess. Service valve stems are factory-torqued from 9 ft.-lbs. ( N*m) for small valves, to ft.-lbs. ( N*m) for large valves) to prevent refrigerant loss during shipping and handling. Using an Allen wrench rated at less than 0Rc risks rounding or breaking off the wrench, or stripping the valve stem recess. See the Lennox Service and Application Notes C-08- for further details and information. Table. Parts Torque Requirements Recommended Torque U.S. Newton-Meter- N Service valve cap 8 ft.-lb. Sheet metal screws in.-lb. Machine screws #0 7 in.-lb. Compressor bolts 7 ft.-lb. 0 Gauge port seal cap 8 ft.-lb. Unit Installation Placement Considerations CAUTION In order to avoid injury, take proper precaution when lifting heavy objects. Consider the following when positioning the unit: In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the unit. In coastal areas, the coil should be cleaned with potable water several times per year to avoid corrosive buildup (salt) Some localities are adopting sound ordinances based on the unit s sound level registered from the adjacent property, not from the property where the unit is installed. Install the unit as far as possible from the property line When possible, do not install the unit directly outside a window. Glass has a very high level of sound transmission Install unit level Ground Level Building Structure Figure. Install Unit Level Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified Choose a location where the hot air discharged from the unit or the operation noise will not be a nuisance to neighbors Avoid installing the outdoor unit near a bedroom or other places where noise may cause a problem There must be sufficient space to carry the unit into and out of the site There must be unobstructed air flow around the air inlet and the air outlet The unit must not be installed in areas where a flammable gas leak may occur Install the outdoor unit a minimum of feet (m) away from any antenna, power cord (line), radio, telephone, security system, or intercom. Electrical interference and radio frequencies from any of these sources may affect operation Since water drains from the outdoor unit during various stages of operation, do not place anything which may be damaged by moisture under the unit Direct Sunlight, Rain, Snow and Ice Protection If the outdoor unit is subjected to prolonged exposure to direct sunlight with temperatures over 00 F (8 C) a canopy is recommended as illustrated in Figure. Unit on Pedestal (Stand) and Protective Canopy on page or Figure 0. Dog House-Style Shelter on page 7 IMPORTANT The construction of a canopy or shade is necessary because of an ambient limit control set to F (0 C) to protect the electronics. If the outdoor unit is placed in direct sunlight it is possible that the limit may activate and shut down the unit. Place unit away from overhanging roof lines which would allow water or ice to drop on, or in front of, coil or into unit. Construct a canopy as illustrated in Figure. Unit on Pedestal (Stand) and Protective Canopy on page

6 The unit base should be elevated above the depth of average snows as illustrated in Figure. Unit on Brackets above Snow Line on page In heavy snow areas, do not place the unit where drifting will occur as illustrated in Figure 7. Unit Air Flow Obstructed by Snow on page Carefully consider how to manage defrost water disposal to prevent ice from blocking walkways or creating a safety hazard near the outdoor unit as illustrated in Figure 8. Avoid Defrost Water Ice Hazard on page 79 in 007 mm Air Outlet in 0 mm Air Inlet Protective canopy Protective canopy Figure 7. Unit Air Flow Obstructed by Snow in 0 mm in 0 mm Air Inlet Air Outlet Pedestal (stand) Pedestal (stand) Side View Front View Figure. Unit on Pedestal (Stand) and Protective Canopy Figure 8. Avoid Defrost Water Ice Hazard Air Outlet Air Inlet Figure. Unit on Brackets above Snow Line Prevailing Winds Normally wind baffles are not required for a outdoor unit. However, in order to maximize reliability and performance, the following best practices should be followed. If unit coil cannot be installed away from prevailing winter winds, some method of protecting the coil is recommended. However, minimum clearances as reference in Figure. Unit Clearances - Inches (mm) on page must be observed at all times. Common application examples are: When prevailing winds are from the air inlet side, then position the wind barrier a minimum of inches (0 mm) from the unit as illustrated in Figure 9. Wind Barrier When prevailing wind is into the discharge side, then position the wind barrier a minimum 79 inches (007 mm) from the front of the unit as illustrated in Figure 9. Wind Barrier unit can be installed in a dog house style shelter as illustrated in Figure 0. Dog House-Style Shelter unit can be installed in a alcove or under a roof overhang as illustrated in Figure. Unit installed in Alcove

7 Prevailing Winter Winds from Air Inlet Side Wind Barrier Inlet Air Discharge Air Wind Barrier (0mm) Min. Distance 79 (007mm) Min. Distance Prevailing Winter Winds From Air Discharge Side Figure 9. Wind Barrier Buried Refrigerant Pipe Protection All refrigerant lines must be insulated regardless of if it is buried In addition to insulating each line of piping, buried lines must rest inside a sealed, watertight conduit The conduit must be designed so it cannot collect and retain water Unit Condensate Piping Condensate formed during the heating and defrost processes must be drained from heat pump units. Drain holes are provided in the base of the units to ensure proper drainage. Heat pumps must be raised when installed on a concrete pad or the ground to allow drainage to occur. If the heat pump unit is installed on wall mounting bracket, insert the provided drain connector into one of the inch ( mm) drain holes and attached a field-provided insulated drain hose to the connector. Use field-provided rubber plugs to cover any unused drain holes. in 0 mm in 0 mm in 0 mm in 0 mm NOTE - Minimum clearances shown. Figure 0. Dog House-Style Shelter in 0 mm in 0 mm NOTE - Minimum clearances shown. in 0 mm in 0 mm Drain Connector Chassis Figure. Condensate Drain Condensate Drain (location varies per model) Securing the Unit Slab or Roof Mounting Install the unit a minimum of inches (0 mm) above the roof or ground surface to avoid ice build-up around the unit. Place the unit above a load bearing wall or area of the roof that can adequately support the unit. Consult local codes for rooftop applications. CAUTION Roof Damage! This system contains both refrigerant and oil. Some rubber roofing material may absorb oil. This will cause the rubber to swell when it comes into contact with oil. The rubber will then bubble and could cause leaks. Protect the roof surface to avoid exposure to refrigerant and oil during service and installation. Failure to follow this notice could result in damage to roof surface. Figure. Unit installed in Alcove 7

8 Securing Unit to Slab, Frame, or Rails If the outdoor unit is installed on a field-provided slab or frame, use lag bolts or equivalent to secure the outdoor unit to the slab or frame. Four Field-provided Anchor Bolts Figure. Securing Unit to Slab Four Field-Provided Anchor Bolts Figure. Securing Unit to Rails Securing Unit To Hanging Brackets If the outdoor unit is installed on field-provided wall mounting brackets, use lag bolts or equivalent to secure the outdoor unit to the bracket. Minimum rear clearance can be reduced to inches ( mm) when mounted on brackets and with no obstructions on the other three sides. Allow for condensate disposal when placing units above one another. Air Outlet in mm Air Inlet Figure. Securing Unit to Brackets Both lines must be individually insulated.. The seal on the unit refrigerant piping connections should remain in place until the last possible moment. This will prevent dust or water from getting into the refrigerant piping before it is connected.. CAREFULLY adjust refrigerant piping connections to suit the application.. Slowly loosen one of the flare nuts to release the factory nitrogen charge from the indoor units only.. Remove the flare nuts from the connections on the unit and discard the seal from each of the piping connections.. Slide the flare nuts onto the ends of the field-provided refrigerant piping before using a suitable flaring tool to flare the end of the copper pipe.. Apply recommended HFC-0A refrigerant lubricant to the outside of the flared refrigerant lines. IMPORTANT The compressor in this unit contains PVE oil (Polyvinylether). PVE oil is formulated for hydrofluorocarbon (HFC) refrigerants, such as HFC- 0A, which this system contains. While it may have some miscibility properties with mineral-based oil and POE oil (Polyolester), it is not recommended to mix PVE oil with any other type of refrigerant oil. 7. Align the threaded connections with the flared refrigerant lines. Tighten the flare nuts lightly at first to obtain a smooth match as illustrated in Figure. Making Connections (Male to Female Connection) on page Once snug, continue another half-turn on each nut which should create a leak-free joint. A torque wrench may be used to tighten flare nuts using Table. Flare Nut Torque Recommendations on page 7 recommendations. Do not over-tighten a flared joint. Flared connections should always be accessible and must be insulated to prevent condensation. 9. After refrigerant piping has been installed and checked for leaks, apply insulation over all flared connections. Table. Refrigerant Piping and Indoor Unit Connection Sizes Size (Btuh) Liquid Line in. Line in / /8 000 / / 8000 / / 000 /8 /8 Refrigerant Piping Connections Field piping consists of two copper lines connecting the outdoor unit to the indoor unit. Table. Refrigerant Piping and Connection Sizes lists the connection sizes. The connections are made using the provided brass flare nuts at the end of the refrigerant piping connections. 8

9 A B CANT ON THE OUTSIDE OF THE FLARE MALE FLARE CONNECTION Figure. Making Connections (Male to Female Connection) IMPORTANT Always use two wrenches when tightening flare nuts to avoid twisting refrigerant piping. DO NOT over-tighten flare nuts. outdoor wire pipe L(ft) Unit D L(ft) Unit C Unit B L(ft) Unit A L(ft) A B C D indoor Unit D Unit C Unit B Unit A Figure 8. Pipe and Wire Each Zone Separately TO INDOOR UNIT TORQUE WRENCH BACKUP WRENCH TO OUTDOOR UNIT Figure 7. Tighten Flare Nut Installation CAUTION In order to avoid injury, take proper precaution when lifting heavy objects. C(/in) C(/8in) B(/in) B(/8in) A(/in) A(/in) Figure 9. Connecting Multiple Indoor Units Please refer to the installation instruction included with the indoor unit for setup. IMPORTANT Pipe and wire to each zone separately. Test each indoor unit separately to ensure proper operation. Connecting Multiple s The largest cpacity indoor unit must be connected to the lowest refirigerant connection ports on the outdoor unit. The,000 Btu indoor unit is only allowed to be connected to MPA08SM, MPB08SM and MLA0SM outdoor units. NOTE: Each indoor unit must be piped AND wired to the correct zone piping connections and wiring terminals. Make sure that indoor unit A is wired to the zone A terminal block and connected to the appropriate refrigerant pipe connections. 9

10 INDOOR UNIT INDOOR UNIT INDOOR UNIT Maximum Elevation - Unit BELOW s 9 ft. ( m) NOTE - Minimum Length - 0 ft. ( m) per NOTE - Maximum Length Includes ALL piping in measurement NOTE - Maximum Difference in Elevation Between s - ft. (0 m). Maximum Furthest OUTDOOR UNIT INDOOR UNIT ft. (0 m) for MPA 9 ft. ( m) for MLA and MPB Maximum Elevation - Unit ABOVE INDOOR UNIT Unit No. Maximum Number of s Connections - Liquid / MPA08SM-*P MPB08SM-*P MLA08SM-*P MPA00SM-*P MPB00SM-*P MLA00SM-*P MPA0SM-*P MPB0SM-*P MLA0SM-*P MPA08SM-*P MPB08SM-*P Two Three Four Five () / / /8 () / / /8 () / / /8 ()/ / / () / / /8 () / / / Total Length of All Piping 98 ft. (0 m) 8 ft. ( m) 97 ft. (0 m) (7 m) Maximum Length - Furthest Indoor Unit ft. (0 m) 8 ft. ( m) 98 ft. (0 m) 98 ft. (0 m) Figure 0. Multi-Zone Systems with All s 0

11 Indoor / Unit Match-Ups Each system is formed of one outdoor unit and a selection of indoor units as referenced in the Product Specifications (EHB). Only these combinations are allowed. NOTE: Each indoor unit must be piped AND wired to the correct zone piping connections and wiring terminals. Make sure that indoor unit A is wired to the zone A terminal block and connected to the appropriate refrigerant pipe connections. Table. MPA & MPB Piping Connections and Usage - MPA08SM & MPB08SM / liq + /8 / liq + /8 (Liquid x ) 0 (A) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). Table. MPA & MPB Piping Connections and Usage - MPA00SM & MPB00SM / liq + /8 / liq + /8 C / liq + /8 (Liquid x ) 08 (A) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit).

12 Table. MPA & MPB Piping Connections and Usage - MPA0SM & MPB0SM / liq + / / liq + /8 C / liq + /8 D / liq + /8 (Liquid x ) / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. Table. MPA & MPB Piping Connections and Usage - MPA0SM & MPB0SM / liq + / / liq + /8 C / liq + /8 D / liq + /8 (Liquid x ) 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit).

13 Table. MPA & MPB Piping Connections and Usage - MPA08SM & MPB08SM / liq + / / liq + / C / liq + /8 D / liq + /8 E / liq + /8 (Liquid x ) / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 0 (B) / in. x / in. 0 (A), /8 in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (C) / in. x /8 in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. Table. MPA & MPB Piping Connections and Usage - MPA08SM & MPB08SM / liq + / / liq + / C / liq + /8 D / liq + /8 E / liq + /8 (Liquid x ) 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 08 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 08 (C) / in. x / in. 08 (B) / in. x / in. 08 (C) / in. x / in. 0 (A), /8 in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in.

14 Table. MPA & MPB Piping Connections and Usage - MPA08SM & MPB08SM / liq + / / liq + / C / liq + /8 D / liq + /8 E / liq + /8 (Liquid x ) 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 08 (A) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 08 (A) / in. x / in. Table. MPA & MPB Piping Connections and Usage - MPA08SM & MPB08SM / liq + / / liq + / C / liq + /8 D / liq + /8 E / liq + /8 (Liquid x ) / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (E) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit).

15 Table 7. / liq + /8 / liq + /8 MLA Piping Connections and Line Set Usage - MLA08SM (Liquid x ) 009 (A) / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). Table 8. MLA Piping Connections and Line Set Usage - MLA00SM / liq + / / liq + /8 C / liq + /8 (Liquid x ) 009 (A) / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. Table 8. MLA Piping Connections and Line Set Usage - MLA00SM / liq + / / liq + /8 C / liq + /8 (Liquid x ) / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit).

16 Table 9. / liq + / / liq + / C / liq + /8 D / liq + /8 MLA Piping Connections and Line Set Usage - MLA0SM (Liquid x ) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 0 (B) / in. x / in. 0 (A), /8 in. x /8 in. 08 (B) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 0 (A), /8 in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. / in. x / in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. Table 9. / liq + / / liq + / C / liq + /8 D / liq + /8 MLA Piping Connections and Line Set Usage - MLA0SM (Liquid x ) 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. /8 x / in. gas pipe adapter is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit). / x /8 in. gas pipe adapter is required for line set connection to the 08 outdoor unit (furnished with outdoor unit).

17 Leak Test and Evacuation Air and moisture remaining in the refrigerant system will have undesirable effects as indicated below: Pressure in the system rises Operating current rises Cooling or heating efficiency drops Moisture in the refrigerant circuit may freeze Water may lead to corrosion of parts in the refrigeration system The line set between the indoor and outdoor units must be leak tested and evacuated to remove any noncondensables and moisture from the system. Leak Test Use the following procedure to test for system leaks:. Connect the manifold gauge set and dry nitrogen gas cylinder to the liquid and gas service ports.. Open valve on nitrogen cylinder.. Pressurize the system per the pressure test specifications in Table 0. Pressure Test Specifications.. Check that the system pressure remains stable. If there is any movement check system for leaks.. After the system is found to be free of leaks: Close valve on nitrogen cylinder. Relieve the nitrogen pressure by: loosening the charge hose connector at the nitrogen cylinder. When the system pressure is reduced to normal, disconnect the hose from the cylinder. IMPORTANT Use only oxygen-free nitrogen (OFN). Triple Evacuation Procedure A Micron or Torr gauge must be used for this procedure.. Discharge the oxygen-free nitrogen and evacuate the system to a reading of 8000 Microns (8 Torr) using all service valves.. Break the vacuum by allowing nitrogen into the port connections (liquid and gas line pipes) until a positive pressure is achieved.. Evacuate the system to a reading of 000 Microns ( Torr).. Break the vacuum by allowing nitrogen into the port connections (liquid and gas line pipes) until a positive pressure is achieved. Evacuate the system to a minimum reading of 00 Microns (0. Torr).. For a moisture-free system, ensure the vacuum is held without movement for a minimum of hours. 7. If vacuum fails to hold, carry out steps through until vacuum holds. Table 0. Pressure Test Specifications bar psig Minimum of 0 minutes bar 0 psig Minimum of 0 minutes bar 70 psig Minimum of 0 minutes bar 0 psig hour. Stress test to prove the integrity of the complete installation. bar 70 psig hours. Lower system pressure test, after confirmation No. was successfully completed. Wiring Connections IMPORTANT Install unit so that unit disconnect is accessible. Use specified wiring and cable to make electrical connections. Clamp cables securely and make sure that connections are tight to avoid strain on wiring. Insecure wiring connections may result in equipment failure and risk of fire. Wiring must be installed so that all cover plates can be securely closed. WARNING Electric Shock Hazard. Can cause injury or death. Unit must be rounded in accordance with national and local codes. Line voltage is present at all components when unit is not in operation. Disconnect all remote electric power supplies before opening access panel. Unit may have multiple power sources. CAUTION All terminal connections must be made as illustrated in the following diagrams. Improperly connected wiring could damage unit or cause communication errors between indoor and outdoor units. In the U.S.A., wiring must conform with current local codes and the current National Electric Code (NEC). In Canada, wiring must conform with current local codes and the current Canadian Electrical Code (CEC). Unit Refer to unit nameplate for minimum circuit ampacity and maximum over-current protection size Make all electrical power wiring connections at the outdoor unit Be sure to reattach all electrical box covers after connections are complete s Refer to the installation instruction included with the indoor unit for further details. 7

18 IMPORTANT All diagrams (Figure through Figure ) are typical wiring diagrams. Refer to the wiring diagram on the unit for actual wiring. 08/0V Unit Terminal Block 08/0V Terminal Block 08/0V Terminal Block L (A) (A) (A) (B) (B) (B) From Power Supply Unit Figure. Connection Diagram - Systems 0k and Below 08/0V Unit Terminal Block L (A) (A) (A) (B) (B) (B) (C) (C) (C) (D) (D) (D) (E) (E) (E) 08/0V Terminal Block 08/0V Terminal Block From Power Supply To E To Unit To C D Figure. Connection Diagram - Systems k and Above 8

19 INDOOR COIL OUTLET TEMP.SENSOR L-OUT T T T OUTDOOR TEMP. SENSOR OUTDOOR COIL TEMP. SENSOR COMPRESSOR DISCHARGE TEMP. CN CN8 CN CN CN9 B A ELECTRONIC EXPANSION VALVE L L (A) (A) (A) (B) (B) (B) WAY VALVE PAN CRANKCASE HEATER HEATER Figure. MPA08SM-*P Unit Wiring Diagram L-PRO LOW PRESSURE SWITCH H-PRO HIGH PRESSURE SWITCH INDOOR COIL OUTLET TEMP.SENSOR YELLOW CN8 T T T OUTDOOR TEMP. SENSOR OUTDOOR COIL TEMP. SENSOR COMPRESSOR DISCHARGE TEMP. CN CN C B A ELECTRONIC EXPANSION VALVE L (A) (A) (A) (B) (B) (B) (C) (C) (C) WAY VALVE PAN CRANKCASE HEATER HEATER Figure. MPA00SM-*P Unit Wiring Diagram 9

20 CN0 P OWER SUPPL Y COMP W V U TP FM DRIVER BOARD CN CN7 W V U CN CN CN 7 SV -WAY HEAT_Y HEAT_D ORANGE ORANGE CN CN CN0 ORANGE ORANGE CN CN0 CN CN MAIN BOARD CN CN A CN0 B CN C CN7 D CN8 M M M M EEV YELLOW L YELLOW CN T T H-PRO L-PRO 7 CN8 CN9 CN7 P- CN CN CN CN CN0 CN9 CN8 CN7 indoor coil outlet temp. sensor CODE COMP PART NAME COMPRESSOR CODE L PART NAME PFC INDUCTOR H-PRO L-PRO LOW PRESSURE SWITCH HIGH PRESSURE SWITCH EEV ELECTRIC EXPANSIVE VALVE T COMPRESSOR DISCHARGE TEMP. FM OUTDOOR DC FAN SV -WAY VALVE HEAT_Y HEAT_D CRANKCASE HEATER PAN HEATER T T CONDENSER TEMPERATURE SENSOR OUTDOOR AMBIENT TEMPERATURE SENSOR Figure. MPA0SM-*P Unit Wiring Diagram YELLOW W V U U V W COMP IPM & PFC BOARD CN Ferrite bead CH CN CN CN9 CN CN9 DCFAN CN8 CN CH 7 Ferrite bead CN7 CN DCFAN SV - W AY D Ferrite bead CH YELLOW CN P- CT CN CN9 CN CN C N 7 C N 8 L MAIN BOARD CN CN P- P- E CN D CN C CN B CN9 A CN7 WHITE L L XT XT (A) (A) (A) (B) (B) (B) (C) (C) (C) (D) (D) (D) (E) (E) (E) XT TO A TO B TO C TO D TO E CODE COMP CT PART NAME COMPRESSOR AC CURRENT DETECTOR D DIODE MODULE DCFAN,DCFAN OUTDOOR DC FAN HEAT_Y CRANKCASE HEATER HEAT_D PAN HEATER H-PRO HIGH PRESSURE SWITCH L PFC INDUCTOR L-PRO LOW PRESSURE SWITCH SV -WAY VALVE DISCHARGE TEMP. SENSOR OUTDOOR COIL TEMP. SENSOR T T T OUTDOOR TEMP. SENSOR HEA T_Y HEA T_D C N C N 0 C N C N 9 CN9 T T YELLOW H-PRO E D C CN CN0 CN B CN A CN TB-A B C D E CN CN8 L-PRO ELECTRONIC ELECTRONIC ELECTRONIC ELECTRONIC ELECTRONIC EXPANSION EXPANSION EXPANSION EXPANSION EXPANSION VALVE E VALVE D VALVE C VALVE B VALVE A E D C B A INDOOR COIL OUTLET TEMP. SENSOR T Figure. MPA08SM-*P Unit Wiring Diagram 0

21 BR OW N BL UE INDO OR COI L OUTL ET TEM P. SEN SOR OUTDOOR TEMPERATURE SE NSOR OUTDOOR COIL TEMPERATURE SEN SOR COMPRE SSOR DI SCHARG E TEMPER ATURE SENSOR BL UE BL UE WHIT E WHIT E HE AT HE AT RE AC TO R L L (A) (A) (A) (B) (B) (B) REACT0R R009A Figure 7. MPB08SM-*P Unit Wiring Diagram WHITE WHITE SV HEAT HEAT L (A) (A) (A) (B) (B) (B) (C) (C) (C) CRANKCASE HEATER PAN HEATER Figure 8. MPB00SM-*P Unit Wiring Diagram

22 ~ ~ ~ P OWE R S UP P LY CO MP W V U FM TP DRIVER BOARD CN C N9 W V U CN CN CN 7 SV -WAY VALVE HEAT_ HEAT_ CN CN CN0 RDE RDE CN CN0 CN CN MAIN B OA RD A CN0 B CN C CN7 D CN8 M M M M EXV EXV EXV EXV YELLOW L YELLOW CN T T H-PRO L-PRO 7 CN8 C N9 C N 7 P- CN CN C N C N CN0 CN9 C N 8 C N 7 CODE COMP PART NAME COMP RESSOR CODE L PART NAME PFC INDUCTOR SV EXV FM HEAT _ HEAT _ -WAY VALVE ELECTRIC EXPANSIO N VALVE OUTDOOR DC FAN CRANKCAS E HEAT ER PAN HEAT ER L-PRO TP TB T T LOW PRESSURE SWIT CH COMPRESSOR D ISCHARGE TEMPERAT URE SENSOR INDOOR COIL OUTLET TEMPERAT URE SENSOR OUTDOOR COIL TEMPERATU RE SENSOR OUTDOOR TEMPERAT URE SENSOR B LACK H-PRO HIGH PRESSURE SWIT CH Figure 9. MPB0SM-*P Unit Wiring Diagram YELLOW L YELLOW CH D CN CN CH CN CT CN P P CN CN P9 CN CN XT L L XT CODE COMP CT D EXV FM, FM HEAT _ PART NAME COMP RESSOR AC CURRENT DETECTOR DIODE MODULE ELECTRIC EXPANSIO N VALVE OUTDOOR DC FAN CRANKCAS E HEAT ER CH CN CN U V W MAIN BOARD CN CN9 HEAT_ H-PRO L L-PRO SV PAN HEATER HIGH PRESSURE SWIT CH PFC INDUCTOR LOW PRE SSURE SWIT CH -WAY VALVE V U W CO MP DR IVER B OARD FAN CH CN9 0 CN CN7 CN0 CN9 CN CN CN8 CN7 ORA NGE ORAN GE XT -WAY VALVE HEAT_ HEAT_ SV TP T T TB XT COMP RESS OR DISCHA RGE TEMP ERA TURE SENS OR OUTDOOR COIL TEMPERATU RE SENSOR OUTDOOR TEMPERAT URE SENSOR INDOOR COIL TEMPER ATUR E SEN SOR TERMINAL STRIP CN CON DC MOT OR DR IVER B OARD FM FM FAN FAN Figure 0. MPB08SM-*P Unit Wiring Diagram

23 INDOOR COIL OUTLET TEMP SENSOR OUTDOOR TEMP SENSOR OUTDOOR TEMP SENSOR D R IV E R B O A R D COMPRESSOR DISCHARGE TEMP SENSOR E X V E X V GN D P- INDUCTOR R07 SV WAY VALVE HE AT _ CR AN KC AS E HE AT ER HE AT _ PAN HE AT ER INDUCTOR R009A Figure. MLA08SM-*P Unit Wiring Diagram HE AT _ HE AT _ IN D O O R C O IL O U TL ET T E M P. S E N S O R GN D P- HEAT_ HEAT_ CRANKCASE HEATER COMPRESSOR DISCHARGE TEMP. SENSOR OUTDOOR COIL TEMP. SENSOR OUTDOOR TEMP. SENSOR INDOOR COIL OUTLET TEMP. SENSOR Figure. MLA00SM-*P Unit Wiring Diagram

24 AC CURRENT DETECTOR HE AT _ HE AT _ PAN HEATER COMPRESSOR DISCHARGE TEMP. SENSOR HE AT _ HE AT _ OUTDOOR COIL TEMP. SENSOR OUTDOOR TEMP. SENSOR INDOOR COIL OUTLET TEMP. SENSOR IND OO R C OIL OU TL ET TE MP. S EN SO R Figure. MLA0SM-*P Unit Wiring Diagram Unit Start-Up IMPORTANT Units should be energized hours before unit start-up to prevent compressor damage as a result of slugging.. Inspect all factory-installed and field-installed wiring for loose connections.. Verify that the manifold gauge set is connected.. Add additional refrigerant charge if required before opening valves and while system is still under a vacuum.. Open the liquid and gas line master valves and each individual port s service valve to release the refrigerant charge contained in outdoor unit into the system.. Replace the stem caps and tighten to the value listed in Table. Torque Requirements on page.. Check voltage supply at the outdoor unit terminal strip. The voltage must be within the range listed on the unit s nameplate. If not, do not start the equipment until you have consulted with the power company and the voltage condition has been corrected. 7. Refer to the included user guide to operate the system using the provided remote control. 8. Visually check for binding of both indoor and outdoor fans. Refrigerant Charge The outdoor unit is factory-charged with refrigerant. Calculate the additional refrigerant required according to the length of the liquid pipe (one way) between the outdoor unit and indoor unit connections. Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Table. Refrigerant Charge System Pre-charge Pipe Length Amount of Refrigerant to add Two-port 0 ft. ( m) 0. oz ((L ft + L ft) - 0 ft) 0.00 kg ((L m + L m) - m) Threeport 7 ft. ( m) Four-port 00 ft. (0 m) Five-port ft. (8 m) 0. oz ((L ft + L ft + L ft) - 7 ft) 0.00 kg ((L m + L m + L m) - m) 0. oz ((L ft + L ft + L ft + L ft) - 00 ft) 0.00 kg ((L m + L m + L m + L m) - 0 m) 0. oz ((L ft + L ft + L ft + L ft + L ft) - ft) 0.00 kg ((L m + L m + L m + L m + L m) - 8 m)

CFFWA-XX-1-U. Rev. 1.2

CFFWA-XX-1-U. Rev. 1.2 CFFWA-XX-1-U Rev. 1.2 CFFWA Universal Mount Fan Coils 12,000-60,000 BTUH -------------------------------------- CAUTION -------------------------------------- Care must be taken when handling sheet metal.

More information

Installation Instructions

Installation Instructions Installation Instructions AquaSnap 010-055 Chilled Water Storage Tank 50/60 Hz Part No: -900---001; -900---009; -900---010 CONTENTS INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................

More information

KM-201BAH KM-260BAH KM-201BWH KM-260BWH SELF-CONTAINED CRESCENT CUBER INSTRUCTION MANUAL L1F (100109)

KM-201BAH KM-260BAH KM-201BWH KM-260BWH SELF-CONTAINED CRESCENT CUBER INSTRUCTION MANUAL L1F (100109) SELF-CONTAINED CRESCENT CUBER KM-201BAH KM-260BAH KM-201BWH KM-260BWH INSTRUCTION MANUAL L1F015102 (100109) IMPORTANT Only qualified service technicians should install, service and maintain the product.

More information

FSFCA (Ductless Direct Expansion Fan Coil) Rev. 1.1

FSFCA (Ductless Direct Expansion Fan Coil) Rev. 1.1 FSFCA (Ductless Direct Expansion Fan Coil) Rev. 1.1 -------------------------------------- CAUTION -------------------------------------- Care must be taken when handling sheet metal. Sheet metal parts

More information

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT DHP MULTI-ZONE PRODUCT SPECIFICATIONS UP TO SEER UP TO DUCTLESS HEAT PUMP SYSTEMS UNITS FORM NO. DHPMULTI-00 (0/07) DHP MULTI-ZONE 8K / 0K / 6K / 8K Mid Efficiency (- SEER) Matches with all indoor units

More information

Instruction Manual. Ventilated Dry-Type Transformers. 600 Volts & Below

Instruction Manual. Ventilated Dry-Type Transformers. 600 Volts & Below Instruction Manual Ventilated Dry-Type Transformers 600 Volts & Below Instructions for the Safe Handling, Installation, Operation and Maintenance of Ventilated Dry-Type Transformers Table of Contents Paragraph

More information

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used

More information

Tindo Karra. Installation and Specifications Manual. Introduction

Tindo Karra. Installation and Specifications Manual. Introduction Tindo Karra Installation and Specifications Manual Introduction Thank you for choosing a Tindo Solar Module. Background to our name TINDO Tindo is a word from the Kaurna warra Aboriginal language which

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit HT-K - Horizontal Flue Gas System For GB125 Oil Condensing Boiler For trained and certified Installers Please read carefully prior to installation. 6

More information

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS DESCRIPTION FrostGuard 120 V preassembled self-regulating heating

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48- 60- 72- 96 long Installation Instructions Supreme Air DYNAMIC BARRIER Bench Fume Hood H50 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH50-SA 06/01 Part Number: IMAN-H50 Kewaunee Scientific Corporation

More information

HNC-120BA-L/R-S HNC-150BA-L/R-S HNC-180BA-L/R-S HNC-210BA-L/R-S

HNC-120BA-L/R-S HNC-150BA-L/R-S HNC-180BA-L/R-S HNC-210BA-L/R-S NO. S041-789 ISSUED: OCT. 26, 2009 REVISED: JAN. 28, 2014 HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BA-L/R-S HNC-150BA-L/R-S HNC-180BA-L/R-S HNC-210BA-L/R-S SERVICE MANUAL IMPORTANT Only qualified service

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

KM-61BAH KM-101BAH KM-151BAH KM-151BWH SELF-CONTAINED CRESCENT CUBER INSTRUCTION MANUAL L1M (100109)

KM-61BAH KM-101BAH KM-151BAH KM-151BWH SELF-CONTAINED CRESCENT CUBER INSTRUCTION MANUAL L1M (100109) SELF-CONTAINED CRESCENT CUBER KM-61BAH KM-101BAH KM-151BAH KM-151BWH INSTRUCTION MANUAL L1M006102 (100109) IMPORTANT Only qualified service technicians should install, service and maintain the product.

More information

SECTION LOW-VOLTAGE TRANSFORMERS

SECTION LOW-VOLTAGE TRANSFORMERS PART 1 GENERAL 1.1 DESCRIPTION SECTION 26 22 00 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // // if not applicable to project. Also, delete any other item or paragraph not

More information

High Temperature Aging Cell Instruction Manual

High Temperature Aging Cell Instruction Manual High Temperature Aging Cell Instruction Manual Part No. 760140001EA Rev. D TABLE OF CONTENTS Section Page Figure 1 General Information... 1 2 Safety Considerations... 3 3 Un-pressurized Testing Procedure...

More information

360 Quality Code. Recommendations for Container Pre-Trip Inspections February 2015

360 Quality Code. Recommendations for Container Pre-Trip Inspections February 2015 Preface These Recommendations relate to the 360 Quality Code prepared and released by the 360 Quality Association. The recommendations provide more detailed information in order to assist the specialized

More information

PACKAGED SYSTEMS INSTALLATION INSTRUCTIONS

PACKAGED SYSTEMS INSTALLATION INSTRUCTIONS PACKAGED SYSTEMS INSTALLATION INSTRUCTIONS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #FMF-03-333

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

2200-Lb. Semi-Electric Stacker OWNER S MANUAL 2200-Lb. Semi-Electric Stacker OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Liner Replacement Instructions:

Liner Replacement Instructions: Liner Replacement Instructions: Before beginning the replacement procedure... Be sure to disconnect electrical service to all of your electrical components of the pool. Use extreme caution when working

More information

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders GEP-6050 Rev. F 23777 Ref. I.D.: 8681 Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders WARNING USER SHOULD READ AND

More information

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ

More information

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ REFRIGERANT CONDENSERS Guide Specifications T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ September 5, 2012 Note: This Specification is for Allied Commercial T-Series 6- to 20-ton, outdoor air conditioner

More information

XAP Series Busduct Storage, Installation, and Maintenance

XAP Series Busduct Storage, Installation, and Maintenance Instruction Booklet IB Joint cover Tap-off Units Contents Description Introduction............................................................... Receiving...............................................................

More information

Operating & Maintenance Manual JEC JCP Series. Centrifugal Pumps

Operating & Maintenance Manual JEC JCP Series. Centrifugal Pumps Operating & Maintenance Manual JEC JCP Series Centrifugal Pumps JEC LTD. 408, Cheongyo-ri, Bibong-myun, Hwaseong-si, Gyeonggi-do, South Korea Tel: +82 31 355 0316 Fax: +82 31 355 0319 www.jecpump.com E-mail:

More information

Preparation and Installation of the MX-9T Rupture Disc / MX-9T / MX-9T-RH Holder Assembly

Preparation and Installation of the MX-9T Rupture Disc / MX-9T / MX-9T-RH Holder Assembly GEP-6077 Rev. D 102335 Ref. I.D.: 17293 Preparation and Installation of the MX-9T Rupture Disc / MX-9T / MX-9T-RH Holder Assembly WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE INSTRUCTIONS BEFORE

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25AGB-W AUG25ALD-W AUG25RLD-W AUY25AGB-W AUY25ALD-W AUY25RLD-W AUT25ALD-W AUT25RLD-W AUG30AGB-W AUG30ALD-W AUG30RLD-W

More information

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER 1. Preface OPERATIONS AND MAINTAINENCE MANUAL 1-800-444-8693 Operation and Maintenance Manual For Amcot LRC-H Cooling Tower & LRC-LNS

More information

Outdoor Enclosure. Installation, Operation and Maintenance Manual

Outdoor Enclosure. Installation, Operation and Maintenance Manual Outdoor Enclosure Installation, Operation and Maintenance Manual f r o m t h e H u m i d i f i c a t i o n E x p e r t s Ta b l e o f c o n t e n t s General information Product overview...3 Dimensions,

More information

BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS

BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED WATERFALLS R BRILLIANT WONDERS LED WATERFALL INSTALLATION INSTRUCTIONS CMP 25677 SERIES Brilliant Wonders LED WATERFALLS TABLE OF CONTENTS 1 Product Overview....2 1.1. Packing List...2 2 Safety.3 3 Installation Guide.....4

More information

Installation Instruction for DMEGC Photovoltaic Module

Installation Instruction for DMEGC Photovoltaic Module Content 1. PURPOSE... 1 1.1 GENERAL TERM... 1 2. SAFETY PRECAUTIONS FOR SOLAR PV SYSTEM INSTALLATION... 3 3. INSTALLATION CONDITION... 4 3.1 INSTALLATION LOCATION AND WORKING CONDITIONS... 4 3.2 SELECTION

More information

HRO-50 Water Purifier

HRO-50 Water Purifier HRO-50 Water Purifier Product Installation & Operation Manual Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd. Content Important Notes P2 Product Functions P3-P5 Installation Instructions

More information

READ THIS MANUAL CAREFULLY BEFORE ASSEMBLY, TESTING & OPERATING

READ THIS MANUAL CAREFULLY BEFORE ASSEMBLY, TESTING & OPERATING The Operator must thoroughly read and understand this manual before operating the dust collector or commencing any servicing. Care should be taken to follow all safety rules and warning instructions. READ

More information

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc Preparation and Installation of the ENVIRO-SEAL I Rupture Disc GEP-6019 Rev. AA 102335 Ref. I.D.: 10711 WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING RUPTURE DISC.

More information

Model m x 1.98 m NPRM with Roof Pads For 1.2 m Antenna Systems

Model m x 1.98 m NPRM with Roof Pads For 1.2 m Antenna Systems Installation Instructions 800026-0 Model 60057-03.98 m x.98 m NPRM with Roof Pads For.2 m Antenna Systems ASC Signal Corporation 35 Industrial Park Drive Smithfield, NC 27577 USA Telephone: +-99-934-97

More information

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012 Product Catalog Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz June 2012 SSP-PRC027-EN General Data Table 1. General Data 7½ - 20 Ton Condensing Units 60 Hz 7½ Tons 10 Tons 15 Tons

More information

Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL

Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL Manufacturer of Coolers, Freezers, Step-Ins, Refrigeration Trailers and Sliding Doors COOLER AND FREEZER INSTALLATION MANUAL http://www.walkincoolersandfreezers.com 786-286-2926 1 BEFORE INSTALLATION Please

More information

Ground Fault Protection. Medium Voltage Artificial Neutrals

Ground Fault Protection. Medium Voltage Artificial Neutrals Ground Fault Protection Medium Voltage Artificial Neutrals Installation and Maintenance Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472

More information

EXPRESS5800/1080Xd. Installation Procedures

EXPRESS5800/1080Xd. Installation Procedures EXPRESS5800/1080Xd () Installation Procedures Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable property

More information

Operating Instructions

Operating Instructions Operating Instructions Series B37000 Hose Reels BB37118 L CB37118 L EB37118 L12D BB37122 L CB37122 L EB37122 L12D BB37128 L CB37128 L EB37128 L12D Dimensional Data C A B D Part # A B C D BB/CB37118 L 31

More information

ChungHo Dealer Technical Guide

ChungHo Dealer Technical Guide ChungHo Dealer Technical Guide Recommendations Prior to Installation -Flush out the system -Check for leaks / hose connections -Test Board connections Installation Procedures -Basic POU Installation -Do

More information

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER: ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER: . INTRODUCTION This manual contains information that will allow to take

More information

Valance Installation. For Units with Beam Style Coils

Valance Installation. For Units with Beam Style Coils Valance Installation For Units with Beam Style Coils 1. Before installation of valance units, determine if drapes are to be used, or if any wall construction will protrude into room. If either drapes or

More information

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL Copyright: November 20, 2018 Revised: Serial No. Gripnail Corporation An Employee Owned Company 97 Dexter Road East Providence, Rhode Island 02914-2045

More information

LIFT FRONT CURVED GLASS HOT FOOD/DELI MERCHANDISERS Hot Temperature Service Display Cases

LIFT FRONT CURVED GLASS HOT FOOD/DELI MERCHANDISERS Hot Temperature Service Display Cases Installation & Service Manual LIFT FRONT CURVED GLASS HOT FOOD/DELI MERCHANDISERS Hot Temperature Service Display Cases Save the Instructions in this Manual for Future Reference!! This merchandiser conforms

More information

DAT Commercial ELECTRIC AIR HANDLERS FOR 7½ & 10-TON SPLIT SYSTEMS

DAT Commercial ELECTRIC AIR HANDLERS FOR 7½ & 10-TON SPLIT SYSTEMS DAT Commercial ELECTRIC AIR HANDLERS F 7½ & 0-TON SPLIT SYSTEMS Contents Nomenclature... Product Specifications... Airflow Data... Heating Kit Data...6 Dimensions...7 Wiring Diagrams...8 Standard Features

More information

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ

More information

Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons

Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons ontents Nomenclature... 2 Product Specifications... 3 Performance Data... 5 Wiring Diagram... 6 Dimensions... 8 Accessories...

More information

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil For

More information

Gerber M Series Site Requirements

Gerber M Series Site Requirements Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick

More information

SoliTek PV Modules INSTALLATION MANUAL

SoliTek PV Modules INSTALLATION MANUAL SoliTek PV Modules INSTALLATION MANUAL Version: 16 10 14 According to: IEC 61215 IEC 61730 For: SOLID PRO 300-310 W p SOLID PRO 250-260 W p SOLID PRO 150-160 W p Thank you for choosing SoliTek panels.

More information

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2 V 2.0 ASSEMBLY GUIDE Series 2 TABLE OF CONTENTS OVERVIEW General Specifications...1 Cautions and Disclaimers...1 Contents of Kit...1 Tools Required For Assembly...2 Time Required to Assemble...2 ASSEMBLING

More information

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 23 81 00 DECENTRALIZED HVAC EQUIPMENT A. The other Contract Documents complement the requirements of this section. The General requirements apply to the work

More information

2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG 2019 V1 SERAPHIM DG PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-2. TELEPHONE: +86-519-88776028 FAX: +86-519-88786181

More information

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL : 514.337.4415 LAVAL (QUEBEC) FAX : 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during

More information

3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide

3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide 3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide Note: Installer - please leave with owner/operator. SAFETY INFORMATION Read, understand, and follow all safety

More information

MODEL INSTALLATION INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard

More information

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting

More information

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG 016 V1 SERAPHIM ECLIPSE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-. TELEPHONE: +86-519-8877608 FAX: +86-519-88786181 MAILBOX: info@seraphim-energy.com

More information

MRI Chiller Installation Guidelines

MRI Chiller Installation Guidelines MRI Chiller Installation Guidelines *These Items are the responsibility of the installing contractor to complete prior to the startup of the MRI Chiller.* **Please refer to DTS chiller manual for further

More information

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS 1 Table of Contents SECTION 1 Unpacking... 3 1.1 Shipping... 3 1.2 Receiving... 3 SECTION 2 Installation... 3 SECTION 3 Inspection... 4 SECTION 4 Connection... 4 4.1 Neutral Lead... 5 4.2 Ground Lead...

More information

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

INSTALLATION INSTRUCTIONS CMP SERIES

INSTALLATION INSTRUCTIONS CMP SERIES INSTALLATION INSTRUCTIONS CMP 25677 SERIES 1. PRODUCT OVERVIEW Thank you for choosing our 25677 Series Brilliant Wonders LED Waterfall. This lighted waterfall will add a unique ambiance to your pool or

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Installation Instructions

Installation Instructions Installation Instructions Flue Gas System Basic Kit GA-K - Chimney Flue Gas System for GB125 Oil Condensing Boiler For trained and certified installers Please read carefully prior to installation. 6 720

More information

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT Page 220548-1 SECTION 220548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

A. Section includes busway and fittings including plug-in units.

A. Section includes busway and fittings including plug-in units. SECTION 26 25 00 ENCLOSED BUS ASSEMBLIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes busway and fittings including plug-in units. 1.2 REFERENCES A. Institute of Electrical and Electronics Engineers:

More information

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP Model T00718 REPAIR PARTS REF. PART DESCRIPTION 1 310883 Upper casing 2 310885 Motor housing 3 310889 Stator 4 310887 Shaft / rotor 5 310895 Mechanical seal 6 310892 Impeller 7 310893 Strainer 8 310890

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

Installation Instructions Snow Melt Mats

Installation Instructions Snow Melt Mats Installation Instructions Snow Melt Mats Contents page Section 1. Overview 1.1 Precautions... 236 1.2 Mat and components... 236 1.3 General accessories... 236 1.4 Tools recommended... 236 1.5 Site plan...

More information

Power Distribution Module Replacement Instructions

Power Distribution Module Replacement Instructions Power Distribution Module Replacement Instructions Introduction This publication describes the replacement procedure for the power distribution module (PDM) in 4100U and 4100ES Fire Alarm Control Panels

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT Page 230548-1 SECTION 230548 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Central Station Air Handler Specification

Central Station Air Handler Specification Central Station Air Handler Specification PART 1: GENERAL 1.01 WORK INCLUDED (Model CS 3 ) Mechanical Specification A. Provide complete air handling unit(s) suitable for indoor installation. Contractor

More information

Zehnder Carboline Radiant Heating and Cooling Ceiling Panels. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

Zehnder Carboline Radiant Heating and Cooling Ceiling Panels. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air Zehnder Carboline Radiant Heating and Cooling Ceiling Panels Installation, Operation and Maintenance Heating Cooling Fresh Air Clean Air ii General information 1 Safety considerations 1 Unpacking and preparation

More information

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016 FW66 FORESTRY WINCH FW66 19/02/2016 Owner s Manual TABLE OF CONTENTS INTRODUCTION ---------------------------------------------------------------------------------- 2 INTENDED USE -----------------------------------------------------------------------------------

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual Solarion M210T General Information This document contains important information for the installation of Solarion M210T solar modules from OC3 AG. Please read this document

More information

TECHNICAL SUPPORT MANUAL Fan Coils FSM2X, FSM4X

TECHNICAL SUPPORT MANUAL Fan Coils FSM2X, FSM4X Fan Coils FSM2X, FSM4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on

More information

PC-PH SERIES BTUH

PC-PH SERIES BTUH C O M I T A L E N A T I O N A L I N C. PC-PH SERIES 7000 18000 BTUH Installation Instructions Comitale National Inc. 1683 B Winchester Road Bensalem, PA 19020 215-244-9650 Fax: 215-244-9679 email: sales@comitalenational.com

More information

Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900)

Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900) Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900) 35 Green Street, PO Box 653, Malden, MA 02148 Tel: (781) 321-5409 - Fax (781) 321-4421 - Toll Free: (800) 343-3618 www.asahi-america.com

More information

VIBRATING CONVEYORS MODEL VMC

VIBRATING CONVEYORS MODEL VMC VM-3671 Installation, Operation and Maintenance Instructions VIBRATING CONVEYORS MODEL VMC ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1440 U.S.A. WORLD AUTHORITY IN ADVANCED TECHNOLOGY

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

H07 H09. BENCH FUME HOOD with Combination Sash. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

H07 H09. BENCH FUME HOOD with Combination Sash. Fume Hoods. Installation Instructions. 48- 60- 72- 96 long Installation Instructions Supreme Air BENCH FUME HOOD with Combination Sash H07 H09 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH07-SA 07/06 Part Number: IMAN-H07 FUME HOOD END PANEL

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

SECTION CONVECTORS

SECTION CONVECTORS SECTION 23 82 33 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

Festoon Manual Heavy Duty C-Track

Festoon Manual Heavy Duty C-Track Festoon Manual Heavy Duty C-Track 966300.3 Heavy Duty C-Track Manual CONDUCTIX INCORPORATED The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES,

More information

Drag Chain Conveyor Installation and Operation Manual

Drag Chain Conveyor Installation and Operation Manual Drag Chain Conveyor Installation and Operation Manual Material Handling Equipment Sales, Incorporated 310 S. Section Line Rd Delaware, OH 43015 Phone: (989) 430-4005 Fax: (740) 363-9004 WARRANTY MATERIAL

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

USER S OPERATING AND INSTRUCTION MANUAL

USER S OPERATING AND INSTRUCTION MANUAL Grand Rapids, Michigan, U.S.A. 49504-5298 USER S OPERATING AND INSTRUCTION MANUAL MODEL 738 MINI CHIP SLICER 0738S20000-CV INDEX Section Description Document No. Page No. SAFETY INSTRUCTIONS --------------------------------------

More information

Installation and Adjustment Manual

Installation and Adjustment Manual Ceiling Mount Unit Installation and Adjustment Manual Thank you for your purchase of this NEC ceiling mount unit. Please read this installation and adjustment manual carefully to ensure proper use. The

More information

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure

More information

2017 V1 SERAPHIM PHOTOVOLTAIC MODULE TUV VERSION B JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD.

2017 V1 SERAPHIM PHOTOVOLTAIC MODULE TUV VERSION B JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. 017 V1 SERAPHIM PHOTOVOLTAIC MODULE TUV VERSION B JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO. 1-. TELEPHONE: +86-519-8877608 FAX: +86-519-88786181

More information

INSTALLATION INSTRUCTIONS. MODEL Version SUMP PUMP

INSTALLATION INSTRUCTIONS. MODEL Version SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com VERSION Z MODELS 300500 SUMP PUMPS Your pump

More information

Operating Instructions April 2010 milltronics WD600

Operating Instructions April 2010 milltronics WD600 Operating Instructions April 2010 milltronics WD600 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

MUSC Psychiatric Hospital CRI Air-Cooled Chiller Replacement Project

MUSC Psychiatric Hospital CRI Air-Cooled Chiller Replacement Project MUSC Psychiatric Hospital CRI Air-Cooled Chiller Replacement Project H51-9832-FW-A ADDENDUM NO. 01 The following items shall take precedence over the drawings and specifications for the above named project

More information

PE21 AMBER DOUBLE SWING OWNER S MANUAL

PE21 AMBER DOUBLE SWING OWNER S MANUAL PE21 AMBER DOUBLE SWING OWNER S MANUAL - Not suitable for children under 36 months due to small parts, cords and the design of the product. - For children ages 3-12 and must be used under adult supervision.

More information

PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL

PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL - Not suitable for children under 36 months due to small parts, cords and the design of the product. - For children ages 3-12 years and must be used under adult

More information