GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER

Size: px
Start display at page:

Download "GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER"

Transcription

1 GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER ALUMINUM GA9000 Recommended for aluminum or aluminum to copper distribution, service or tap connections. Add Suffix G to catalog number for neoprene grommets. Grommet holds spacer bar in place during installation. Sealant is recommended on all connectors. Optional snap-on cover Optional - Class AA temperature rated per ANSI C119.4 Body Aluminum Alloy Spacer Aluminum Hardware Aluminum Alloy (std.) or Stainless Steel ( SS suffix) Options: Snap-On Cover (See Column) (B-Suffix) Torque-Head Bolts (Add O Suffix) Grommets G suffix L Inhibitor applied (std.) AA - Class AA rated Ex: GA900GAASSB or GA9041GLOB3 G Grommet Suffix Optional grommet aids in positioning spacer bar. See note below. 1 SINGLE BOLT ALUMINUM CONNECTORS CONDUCTOR RANGE RUN TAP MAX. MIN. MAX. MIN. AL. OR CU. ACSR STANDARD CLASS AA ACSR AL. ACSR AL. ACSR AL. OR CU. GA9003L** GA9003AA 4 Sol. 6 8 Sol. 4 Sol. 6 8 Sol. GA900L** GA900AA 1 Str. 6 6 Sol. 1 Str. 6 1 Sol. GA900LSS** GA900AASS 1/0 /0 Str. 6 6 Sol. 1/0 /0 Str. 6 6 Sol. GA9040L** GA9040AA 4/0 4/0 Str. 1 Str. 4/0 4/0 Str. 1 Str. GA9041L** GA9041AA 4/0 4/0 Str. 1 Str. /0 /0 Str. 6 6 Sol. GA9405L GA9405AA 3/0 3/0 Str. 4 4 Str. 4 Str. 1 Sol. GA9400L GA9400AA 336, ,500 3/0 4/0 Str. 336, ,500 3/0 4/0 Str. GA9401L GA9401AA 336, ,500 3/0 4/0 Str. 4/0 66, Sol. GA984L** GA984AA 666, ,000 4/0 66,800 /0 /0 6 6 Sol. GA9843L** GA9843AA 666, ,000 4/0 66,800 4/0 4/0 1 Str. CONNECTORS FOR SPECIAL APPLICATIONS A INCHES 7/8 (.7) 1-1/8 (8.63) 1-1/4 (31.81) 1- (38.18) 1- (38.18) 1- (38.18) -1/16 (5.50) -1/16 (5.50) (50.90) (50.90) 1-1/8 GA9404L GA9404AA 4/0 4/0 4 4 Str. 10 Sol. 1 Sol. (8.63) 3 GA9844L 666, , , , , ,500 4/0 66,800 (76.35) 3 GA9954L GA9954AA 795,000* 954, , ,400 1/0 (76.35) B INCH- ES 1-1/4 (31.81) 1 7/8 (47.7) 1 -/8 (47.7) - (69.99) 3- (85.89) 1-7/8 (47.7) 3- (89.08) 4 (101.80) 3- (9.6) 3- (9.6) 1-7/8 (47.7) 3 (76.35) 3 (76.35) C INCH- ES 1- (44.54) -1/8 (54.08) - (60.44) 3-1/8 (79.53) 3-1/8 (79.53) - (63.63) 3- (89.08) 3- (89.08) 3- (95.44) 3- (95.44) -1/8 (54.08) 4- (10.89) 4 (10.89) AP- PROX. WT. EACH LBS. (KG) *795 ACSR 6/7 ** RUS Listed Feature: G Soft flexible grommets hold the spacer bar in position for easy installation of the run and tap. The grommets do not interfere with the smooth operation of the connector..17 (.08).3 (.10).34 (.15).55 (.5).58 (.6).44 (.0).78 (.35).84 (.38).80 (.36).88 (.40).39 (.18) 1.4 (.56) 1.4 (.56) INSULATED SNAP-ON COVER GA9000B** GA9000B** GA9000B** GA9000B3** GA9000B3** GA9000B** GA9000B3** GA9000B3** GA9000B3** GA9000B3** GA9000B** GA9000B5** GA9000B5**

2 ALUMINUM GA9000 GENERAL USE VISE TYPE, TWO- BOLT EXTENDED RANGE ALUMINUM ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER Heavy duty construction for aluminum to aluminum or aluminum to copper conductor connections. Sealant is recommended for all connections. Body Aluminum Alloy Spacer Aluminum Hardware Aluminum Alloy (std.) or Stainless steel ( SS Suffix) A Dimension depends on bolt extension/conductor size opening. G Grommet Suffix Optional grommet aids in positioning spacer bar. See note below. GA9000Bx Series Snap-On Cover RUN CONDUCTOR RANGE INCHES AP- PROX. WT. EACH LBS. (KG) * For insulated Snap-On Cover order Catalog No. GA9000B4. 6/7 ACSR Feature: G Soft flexible grommets hold the spacer bar in position for easy installation of the run and tap. The grommets do not interfere with the smooth operation of the connector. TAP MAX. MIN. MAX. MIN. STAN- DARD CLASS AA ACSR AL. ACSR AL. ACSR AL. OR CU. ACSR AL. OR CU. GA950GL* GA950GAA* 477, ,000 4/0 4/0 477, ,000 4/0 4/0 GA951GL* GA951GAA* 477, ,000 4/0 50,000 4/0 66, Str. GA980GL GA980GAA 795, , , , , , , ,000 GA981GL GA981GAA 795, , , , , ,000 3/0 4/0 GA9100GL GA9100GAA 1,7,000 1,500, , ,000 1,7,000 1,500, , ,000 GA9101GL GA9101GAA 1,7,000 1,500, , , , , , ,400 (NOMI- NAL) A 4 (101.80) 4 (101.80) 5- (139.98) 5- (139.98) 5- (146.34) 5- (146.34) B 4-1/4 (108.16) 4-1/4 (108.16) 4- (114.53) 4- (114.53) 6-1/4 (159.06) 6-1/4 (159.06) C - (63.63) - (63.63) - (69.99) - (69.99) -7/8 (73.17) -7/8 (73.17) 1.44 (.65) 1.5 (.69).40 (1.09).30 (1.04) 4.50 (.04) 4.60 (.09)

3 GENERAL USE VISE TYPE COPPER TO COPPER For copper connections-splice, Loop deadend or service entrance tap or grounding connections One piece design for easier, faster installation Bolt head design for use with standard ratchet wrench Vise design achieves high connector pressure with low wrench force GC5000 SERIES Options: Body Copper Alloy Hardware Stainless Steel or Silicon Bronze Alloy Suffix P Tin-plated 3 TOP VIEW SIDE VIEW CONDUCTOR RANGE MAX. CONDUCTORS MIN. CONDUCTORS DIA. RANGE ( COND. COMBO.) DIA. EA. COND. MIN. - MAX. A B C WT. EA. LB (KG) BOLT HEAD (HEX.) GC5008SH* #8 STR. #11 SOL (.3-3.7) 7/8 (.7) (15.91).06 (.03) GC5006** GC5006SH* #6 SOL. #10 SOL ( ) 1 (5.45) (15.91) (19.09).09 (.04) (10) GC5004** #4 STR. #8 SOL ( ) 1-1/4 (31.81) 7/8 (.7).16 (.07) GC500** # SOL. #6 SOL. GC500S** # STR. #5 SOL. GC500** 1/0 STR. #4 SOL ( ) ( ) ( ) 1- (34.99) 1- (41.36) 1-7/8 (47.7) (19.09) 1 (5.45) 1-1/8.18 (.08) (8.63).8 9/16 (14) GC500S** /0 STR. #3 SOL ( ) (50.90) 7/8 (.7) 1-1/4 (31.81) (.13) GC5040** 4/0 STR. #1 SOL ( ) -1/8 (54.08) 1 (5.45) 1- (34.99).48 (.) * SH suffix indicates a slotted hex-head bolt. **RUS Listed For tin-plated bronze connectors, add suffix P to catalog number (not available on GC5006S, GC5006SH and GC5008SH) Note: All connectors will accept one or two of the conductors listed and any combination in between.

4 GC SERIES GC100/ 00/5000 GENERAL USE GROUNDING AND BONDING VISE TYPE For copper to copper connections or conductor to conductor and conductor/cable sheath to bar. Copper Alloy Stainless Steel or Silicon Bronze slotted head hex GC5000 Series 4 GC71* RANGE INCHES CONDUCTOR COMBINATIONS CABLE BOLT SHEATH A B C RUN TAP BONDING DIA. WRENCH Sol 6 Str to 3 pair GC5006SH* to 3 pair GC5006 ** to 3 pair GC5004 ** (5.45) 1 (5.45) 1 (5.45) 1 to 3 pair 1-1/4 1 5 pair GC500** 6- * Slotted Head Bolt Complies with UL-467 and ETL listed **RUS Listed (31.81) 1- (35.00) (15.90) (15.90) (15.90) (15.90) (19.08) (19.08) (19.08) (19.08) 7/8 (.6) 1 (5.45) 1/4 (6.36) 1/4 (6.36) 1/4 (6.36) 5/16 (7.95) 5/16 (7.95) (10) (10) (10) 9/16 (14) 9/16 (14) WT LB (KG).08 (.04).09 (.04).09 (.04).16 (.07).18 (.08) For Figure 8 or IM Cable Insulation Piercing The piercing teeth of the connector puncture the messenger insulation during tightening to form a positive ground without skinning. GC167 CATA- LOG MESSENGER DIAMETER GROUND TAP A INCHES B C DIA. BOLT WRENCH WT LB (KG) GC167 GC167P ( ) ( ) 1- (41.36) 1-1/4 (31.81) 1 (5.45) 5/16 (7.95) 9/16 (14).1 (.10) *Suffix P Tin-Plated Bronze

5 GENERAL USE GROUNDING AND BONDING VISE TYPE For Bonding Ribbon, Braid and Tape Bonding ribbon or braid to bonding ribbon, braid, conductor, or bus and tape to messenger. GC164 GC164P Plated Bronze BONDING RIBBON OR BRAID CONNECT Ribbon or Braid TO Ribbon, Braid, #6 or Bus A 1 (5.45) INCHES B (15.90) C 1 (5.45) DIA. 1/4 (6.36) BOLT WRENCH (10) WT LB (KG).1 (.05) GC164 For Ground Rods ROD DIA. INCHES RANGE CONDUC- TOR A INCHES B C DIA. BOLT WRENCH WT LB (KG) 5 GC68 1/4 ( ) 6-1/0 1 (5.45) 1- (35.00) (9.54) 9/16 (14).43 (.19) * Torque head bolts available for tamperproof, removeable connection. Complies with UL-467 and ETL listed GC68 For Lashing Wire Connect small diameter lashing wires to messengers. MESSENGER DIAMETER RANGE LASHING WIRE INCHES CONNECT TO A B C DIA. BOLT WRENCH WT LB (KG) GC166 GC166P ( ) All Sizes 1- (38.18) 7/8 (.6) 1 (5.45) 1/4 (6.36) (10).16 (.07) Suffix P- Plated Bronze For Guy Strand Aluminum bodied connectors for connecting galvanized or aluminum clad strand to copper conductors. Vise Type Parallel Connector. GA9003L** GA900L** LC5AXB* ** LC5AXB ** STRAND RANGE (IN.) 1/4 (6.36) 1/4 ( ) 1/4 ( ) CONDUCTOR RANGE INCHES A 7/8 (.6) 1-1/8 (8.63) PARALLEL GROOVE TYPE /0 8 - (60.44) B 1-1/4 (31.81) 1-7/8 (47.7) 1- (41.36) C 1- (44.54) -1/8 (54.08) 1- (35.00) WT LB (KG).17 (.08).3 (.10).0 (.09) GC166 GA9000 Series * Inhibitor Protected and Individually Packaged Standard Bimetallic Liner on Tap Side Copper **RUS Listed LC50 Series

6 KUL KUL Clamp - Tin-Plated Bronze Clamp with Interlocking Jaws Tin plated for corrosion protection High strength copper alloy Half-inch hex head silicon bronze bolt Application: 1/4-7/16 strand #8 - #/0 copper wire 6 KUL14716BG (Top) KUL14716 (Bottom) *GC09 is furnished with bronze jam nut on stud. +Add Suffix P for Tin-plated Version (Minimum purchase quantities may apply) **RUS Listed DESCRIPTION PACKAGING KUL % tin plated Standard Packaging: 100/box. No Minimum Order KUL14716BG Tin plated with one bare bronze groove Standard Packaging: 100/box. No Minimum Order Provides a permanent vibration proof connection. The large flat surface of the male casting provides secure mounting, while the V shaped conductor groove assures alignment of grounding connector.

7 GROUNDING CONNECTOR WIRE TO ROD OR PIPE GC/C03 Bronze alloy ground clamp for grounding copper cable parallel to a ground rod or tube. Suitable for Direct Burial GC Casting Bronze Alloy Hardware Stainless Steel C03 Casting Galvanized Steel Hardware Zinc Plated LISTED 61L 7 COPPER CABLE RANGE ROD DIA. GC4 #8 Sol. #4 Str. GC5G5 #10 Sol. # Str. C Heavy Duty C Heavy Duty #8 Sol. /0 Str. #8 Sol. /0 Str. INCHES L H W J 1-7/8 13/16 (15.88) (47.6) (0.64) (9.5) 1-19/3 9/3 (15.88) (40.39) (3.11) (9.5) 1-1/8-7/8 1-15/3 (8.6) (73.0) (37.3) (1.7) 1-1/8-7/8 1-15/3 (8.6) (73.0) (37.3) (1.7).09 (.04).11 (.05).34 (.15).30 (.14)

8 GC00 SERIES GENERAL USE VISE TYPE GROUND CLAMP LIGHTNING ARRESTER GROUND For grounding applications Provided with standard -13 threaded studs and flat surfaces for easy one wrench installation Note: Body Copper Alloy Hardware Stainless Steel Lightning Arrester type installations, see DC-11. GC07 FIGURE 1 TYPE 8 GC07-GC09 GC07+** (Fig. 1) GC08+ (Fig. 1) GC09*+ (Fig. 1) CONDUCTOR RANGE 6 Sol. To 1/0 Str. 4 Str. To /0 Str. 3 Sol. To 4/0 Str. GROUNDING CONNECTOR INCHES A B C D E 1-1/4 (31.81) 1-5/16 (33.40) 1- (38.18) (19.09) 13/16 (0.68) 1-1/8 (8.63) 1-7/8 (47.7) 1-7/8 (47.7) 1- (44.54) (1.73) (1.73) (1.73) 5/16 (7.95) 5/16 (7.95) 5/16 (7.95) WT LB (KG).1 (.10).9 (.13).40 (.18) *GC09 is furnished with bronze jam nut on stud. +Add Suffix P for Tin-plated Version (Minimum purchase quantities may apply) **RUS Listed The large flat surface of the male casting provides secure mounting, while the V shaped conductor groove assures alignment of grounding connector.

9 GROUND CLAMP CONDUCTOR TO TRANSFORMER TANK TYPE GTCL: 90 GROUND CONDUCTOR MOUNT Bronze alloy ground clamp for tapping copper conductor to transformer tank Tapered threads at base of stud ensure positive locking and electrical contact without lockwashers GTCL Bronze Alloy Bronze Alloy Silicon Bronze Alloy or Stainless Steel Add suffix TP for tin-plated version. COPPER CABLE RANGE INCHES L H W J WT. EACH LBS. (KG) 9 GTCL3A* #10 Sol. #1 Str. 7/8 (.) 1- (38.1) 1- (34.9) (9.5).0 (.09) GTCL34A* #8 Sol. /0 Str. 1 (5.4) 1-7/8 (47.6) 1-17/3 (38.89) (9.5).5 (.11) *RUS Listed GROUND CLAMP CONDUCTOR TO TRANSFORMER TANK TYPE GTCS: 90 OR STRAIGHT GROUND MOUNT Bronze alloy ground clamp for tapping copper conductor to transformer tank Tapered thread at base of stud ensures positive locking and electrical contact without lockwashers. Hex wrenching surface above tapered thread provides easy installation. GTCS Casting Bronze Alloy Eyebolt Bronze Alloy Hardware Silicon Bronze Alloy or Stainless Steel Add suffix TP for tin-plated version. COPPER CABLE RANGE INCHES L H W J WT. EACH LBS. (KG) GTCS1 #10 Sol. #1 Str. 1-1/8 (8.58) 1- (41.8) 1-7/8 (47.6) (9.5).9 (.13) GTCS34A #8 Sol. /0 Str. 1-1/4 (31.75) 1-7/8 (47.6) -1/4 (57.7) (9.5).34 (.15) GTCS41 #6 Sol. 50 MCM 1- (41.8) - (60.3) - (63.5) (1.7).45 (.0)

10 LAT, GC07LA LIGHTNING ARRESTER GROUNDING TERMINALS TYPE LAT AND GC07LA DISTRIBUTION ARRESTER TERMINALS (See also Page DC7) This versatile bronze connector can be mounted to a drilled plate, structure or bar using a -16 cap screw. It can also be screwed onto a -16 bushing stud and secured in place with the included jam nut. The eyebolt can be positioned within the body to allow either vertical or horizontal conductor entrances. Casting Bronze Alloy Eyebolt Bronze Alloy Hardware Silicon Bronze Alloy Brass jam nut 10 STUD SIZE CONDUCTOR RANGE O.D. LENGTH INCHES WT. EACH LAT Sol. - /0 Str O.D (43) 40 (18) Add suffix TP for tin-plated connector This connector is intended primarily for bottom termination of lightning arresters to ground. May also be employed on top connections. Note: Casting Bronze Alloy Eyebolt Bronze Alloy Hardware Stainless Steel See pages DC-9 DC-10 for application details. STUD SIZE GC07LA - 16 Add suffix P for tin-plated connector CONDUCTOR RANGE O.D. #6 Sol. - 1/0 Str ( ) mm WT. 100 (9.9)

11 TYPE APD ARC PROTECTION FOR COVERED PRIMARY CONDUCTOR ALUMINUM APD The APD helps prevent lightning induced burndowns of covered overhead aluminum primary conductors and allows users to comply with Article 76 of the National Electric Safety Code, 1981 Edition. The device protects covered conductor by shielding it from the usual concentration of arc energy generated during a lightning strike. Without the device, such arcs can puncture the conductor cover and ground to the neutral leaving a short section of conductor strands that are either completely destroyed or badly eroded and seriously weakened. (Conventional overcurrent protection equipment does not operate fast enough to protect these lightning exposed conductors.) APD lightning protectors add mass of the correct shape to the conductor in the area where it absorbs the terminus of arc energy. It is thus a partially sacrificed component during each strike yet retains enough of its original mass and configuration to accommodate several strikes without losing effectiveness or allowing the adjacent line insulator to be splattered with damaging metallic particles. APD lightning protectors are both laboratory tested and field proven with the same successful results. They are offered in two models. The high energy APD-80 model is designed to withstand multiple operations at 1,000 amperes fault current for ten (10) cycles without conductor damage. A low-energy APD-57 model is available for applications where fuses limit the destructive energy by clearing the fault more rapidly than circuit breakers. 11 Note: Castings Aluminum Alloy Hardware APD57 Galvanized Steel APD80 Stainless Steel A radial circuit requires an APD protector on the load side of the insulator only, while other circuit configurations, such as loops, require that they be installed on both sides of the line insulator. In both situations, they must be installed on all conductor phases and positioned outside the end of a tie wire. The covering must be stripped away over this distance including the area within the confines of a tie wire. Since an arc from one phase to the neutral will often expand to fault all three phases, the device must be installed on all three phases. (WITH INHIBITOR) MAX. O.D. OF CABLE JACKET INCHES CONDUCTOR RANGE O.D. IN INCHES DIMENSION B INCHES WT. 100 (1) APD57XB (Fused circuits) #1-4/0 STR. AAC #-4/0 ACSR (7) 4 (11) APD80XB 1.00 / Str. AAC 1/0-477 (18/1) ACSR (48) 66 (30) (1) This item is suitable for use on fused circuits only. Specifically, it should not be installed on lines protected by circuit breakers because of their relatively slow interrupting rate.

12 BXS TINNED ALUMINUM OR TRANSFORMER SPADE TERMINALS TYPE AXS & BXS ALUMINUM AXS Secured by jam nut to bushing stud. Recommended when copper terminals are connected (Use AXS style for aluminum terminals.) Terminal lug mounting holes are 9/16 diameter with 1- NEMA spacing. Jam nuts are usually supplied by the transformer manufacturer and are not furnished unless specified. 1 Notes: - Bronze Alloy (tin-plated) - Aluminum Alloy (tin-plated) (1) Terminals for 1-1/4 1 bushing studs can be furnished with a 1/4 0 tapped hole in the outer end to attach an insulated suspension support rod for mechanical support. Add suffix -MS for this option. () Add suffix JN to specify a factory applied brass jam nut. X FORMER STUD SIZE GENERAL DESCRIPTION & FIELD APPLICATION BXS58N -11 Two Holes in Line NEMA Spaced INCHES LENGTH WIDTH HEIGHT WT (130) 1.37 (35) 0.31 (8) 70 (3) BXS10N 1-14 For Use With One Hole Lugs 5.06 (19) 1.93 (49) 0.34 (9) 14 (64) BXS584N (16) 1.37 (35) 0.31 (8) 10 (54) BXS104N AXS584NTP Four Holes in Line NEMA Spaced For Use With One Hole Lugs 8.56 (18) 8.50 (16) 1.93 (49) 1.37 (35) 0.34 (9) 0.31 (8) 15 (98) 36 (16) AXS104NTP (18).00 (50) 0.34 (9) 65 (9) BXS58BN (136) 3.50 (89) 0.5 (6) 13 (60) BXS10BN 1-14 Two Sets of NEMA Spaced Holes Mounts Up to 4 Two-Holed Lugs 5.87 (149) 3.50 (89) 0.37 (9) 60 (118) AXS58BNTP (136) 3.50 (89) 0.5 (6) 39 (18) BXS583BN (168) 3.50 (89) 0.37 (9) 56 (116) BXS103BN 1-14 Three Sets of NEMA Spaced Holes Mounts Up to 6 Two-Holed Lugs 7.00 (178) 3.50 (89) 0.37 (9) 315 (143) AXS103BNTP (178) 3.50 (89) 0.37 (9) 94 (43) BXS584BN -11 Four Sets of NEMA Spaced Holes 8.37 (13) 3.50 (89) 0.37 (9) 330 (150) BXS104BN 1-14 Mounts Up to 8 Two-Holed Lugs 8.75 () 3.50 (89) 0.37 (9) 36 (164) Three Sets of NEMA Spaced Holes BXS13BN 1-1/4-1 Mounts Up to 6 Two-Holed Lugs Or 7.1 (181) 3.50 (89) 0.37 (9) 345 (156) Up to 1 Two-Holed Lugs If Stacked Four Sets of NEMA Spaced Holes BXS14BN 1-1/4-1 Mounts Up to 8 Two-Holed Lugs Or 9.1 (3) 3.50 (89) 0.37 (9) 445 (0) Up to 16 Two-Holed Lugs If Stacked Six Sets of NEMA Spaced Holes BXS16BN 1-1/4-1 Mounts Up to 1 Two-Holed Lugs Or (356) 4.00 (10) 0.50 (13) 970 (440) Up to 4 Two-Holed Lugs If Stacked Eight Sets of NEMA Spaced Holes BXS18BN 1-1/4-1 Mounts Up to 16 Two-Holed Lugs Or (445) 4.00 (10) 0.50 (13) 1300 (590) Up to 3 Two-Holed Lugs If Stacked

13 OVERHEAD TRANSFORMER PAD ADAPTER CONNECTORS TIN-PLATED FLAG ADAPTERS USE W/EYEBOLT (GTCL/GTCS) TYPE SECONDARY BUSHING TERMINALS VF Bronze terminal adapter for connecting a flat pad to NEMA secondary transformer terminal Optional for use with Type GTCL or GTCS terminals. Bronze Alloy (tin-plated) 13 NEMA DRILLED PAD & ROD DESCRIPTION TRANSFORMER SIZE RATING (SINGLE PHASE) INCHES L DIA. WT. 100 VF440 4 Hole 4 x 4 x 1/4 Pad (75) 5-15 KVA VF640 6 Hole 3 x 5-1/4 x 1/4 Pad (57) (13) 180 (8) VF Hole 4 x 4 x 1/4 Pad (98) 5-50 KVA VF Hole 3 x 5-1/4 x 1/4 Pad (70) (0) 31 (105) VF Hole 4 x 4 x 1/4 Pad (111) 75 KVA VF Hole 3 x 5-1/4 x 1/4 Pad (10) (1) 60 (118) VF Hole 4 x 4 x 1/4 Pad (14) 100 KVA VF Hole 3 x 5-1/4 x 1/4 Pad (10) (5) 37 (148)

14 ALUMINUM UTSB SET SCREW BAR TRANSFORMER CONNECTORS TOGGLE LATCH For connecting secondary underground applications to transformer studs. Innovative Toggle Latch mechanism provides unmatched ease of installation, along with superior electrical performance. One part accepts both -11 and 1-14 threads. Reduced inventory; one part accepts both -11 and 1-14 thread transformer studs. Oxide Inhibiting Compound provided as standard in stud and tap holes. 5/16 allen set screws provide constant pressure on conductors. Testing meets or exceeds ANSI C119.6 Class A tests. Redundant ground ports provided for use on neutral phase connections. Toggle nut is across flats, fits standard GP3 Speed Wrench. 14 Note: Body Aluminum Alloy Hardware High Strength Steel Boot/Cover Poly-vinyl Chloride (PVC) Not suitable for submersible installations. TRANS- FORMER STUD SIZES MAIN PORTS CONDUCTOR RANGE STREET LIGHT PORT REDUNDANT GROUND MAIN PORTS STREET LIGHT PORTS GROUND PORTS PACKAGING PER BOX UNITS WEIGHT (LBS) UTSB8500L -11 & 1-14 #6 SOL MCM #1 SOL - 1/0 SOL #1 SOL - # SOL NOTE: Add suffix C for clear PVC cover included in package UTSB8500CL. Factory applied inhibitor (HTJC) included standard. Cover Part Number: CTL8500

15 SET SCREW BAR TRANSFORMER CONNECTORS TOGGLE LATCH ALUMINUM UTZB For connecting secondary underground applications to transformer studs. Innovative Toggle Latch mechanism provides unmatched ease of installation, along with superior electrical performance. Reduced inventory; one part accepts both -11 and 1-14 thread transformer studs. Oxide Inhibiting Compound provided as part of standard in stud and tap holes. Allen head set screws (fits 5/16 allen wrench) provide constant pressure on conductors. Meets or exceeds ANSI C119.6 Class A tests. Toggle nut is across flats, fits standard GP3 Speed Wrench. Note: Body Aluminum Alloy Set Screws Aluminum Alloy Hardware High Strength Steel Boot/Cover Poly-vinyl Chloride (PVC) Not suitable for submersible installations. 15 Units are expressed in inches (millimeters) TRANSFORMER STUD SIZES MAIN PORTS CONDUCTOR RANGE STREET LIGHT PORT MAIN PORTS STREET LIGHT PORTS PACKAGING PER BOX UNITS WEIGHT (LBS) UTZB6500L -11 & 1-14 #6 SOL MCM #1 SOL - 1/0 SOL NOTE: Add suffix C for kit with stud bar & clear PVC cover (UTZB6500CL). Factory applied inhibitor (HTJC) included standard. Cover Part Number: CZTL6500

16 GC8000 GENERAL USE VISE TYPE PARALLEL GROOVE For copper to copper conductor - splice, loop deadend or service entrance taps. Castings Copper Alloy Hardware Stainless Steel Galvanized Steel Silicon Bronze 16 *CONDUCTOR RANGE (AWG) MAIN MIN. SOL. STR. SOL. INCHES A B C BOLT SIZE BOLT HEAD (HEX) WT. GC800*GL (34.99) 1 1/4 (31.81) 7/8 (.7) 5/16 (7.95) 9/16 (14.3).16 (.07) GC8010*GL 1/ (38.18) 1 (34.99) 1 (5.45) 5/16 (7.95) 9/16 (14.3).4 (.11) GC800*GL 3/0 /0 8 1 (44.54) 1 (34.99) 1 1/8 (8.63) 5/16 (7.95) 9/16 (14.3).33 (.15) GC8040*GL 4/0 4/0 6 (60.44) 1 (38.18) 1 (38.18) (9.54) 9/16 (14.3).6 (.8) For Tin-plated Connectors replace * with P in Catalog Number. **RUS Listed *Conductor Range Each size will close on two of the maximum size conductors, one minimum and one maximum size, or combinations in between. Inhibitor Protected and Bagged All connectors come with factory installed HTJC inhibitor and individually packaged.

17 GENERAL USE PARALLEL GROOVE ALUMINUM MULTIPLE U-BOLTS WITH COPPER LINER ALUMINUM LCC For aluminum to copper conductor connections only. Sealant (XB) is recommended on all connections. Body Top member 356-T6 Aluminum Alloy Spacer Aluminum Alloy with a metallurgically bonded Copper liner Bottom Member High Strength Bronze Hardware Galvanized Steel FIGURE 1 FIGURE FIGURE NUM- BER LCC111XB 1 CONDUCTOR RANGE INCHES MAIN TAP L W H #6 Sol. /0 Str. AAC #8 Sol. /0 (6/1) ACSR #8 Sol. /0 Str. CU -5/16 (58.74) 3- (88.90).77 (.35) 17 LCC1XB 1 1/0 Str. 400 MCM AAC 1/0 (6/1) (18/1)ACSR #4 Sol. 4/0 Str. CU - (63.50) -11/16 (68.6) 4 (101.60) 1.11 (.50) LCCXB 1/0 Str. 400 MCM AAC 1/0 (6/1) (18/1) ACSR #4 Sol. 4/0 Str. CU 3-7/8 (98.43) - (69.85) 4 (101.60) 1.68 (.76) LCC31XB 1 1/0 Str. 400 MCM AAC 1/0 (6/1) (18/1) ACSR 1/0 Str. 500 MCM CU - (63.50) -11/16 (68.6) 4 (101.60) 1.4 (.56) LCC4XB 1/0 Str. 400 MCM AAC 1/0 (6/1) (18/1) ACSR MCM CU 4-1/8 (104.78) -11/16 (68.6) 4-1/4 (107.95).10 (.95) LCC33XB MCM AAC MCM ACSR 1/0 Str. 400 MCM CU 4- (117.48) 3-1/16 (77.79) 4- (117.48).88 (1.31) GENERAL USE PARALLEL GROOVE ALUMINUM THREE CENTER BOLTS WITH COPPER LINER ALUMINUM LC600 For aluminum to copper conductor connections only. Sealant (XB suffix) is recommended on all connections. Body 356-T6 Aluminum Alloy Hardware Hot Dip Galvanized Steel Tap Liner Copper, Metallurgically Bonded LC677XB CONDUCTOR RANGE INCHES 1/0 (19) MCM AAC 1/0 300 MCM ACSR 1/0 (7) 50 Str. CU 4- (111.13) -5/16 (58.74) - (63.5) (1.7) 1.35 (.61)

18 ALUMINUM LC50 & LC80 GENERAL USE PARALLEL GROOVE ALUMINUM SINGLE CENTER BOLT For aluminum to aluminum and aluminum to copper conductor splice/ tap connections. Sealant (XB) is recommended on all connections. Body Aluminum Alloy Hardware Galvanized Steel 18 FIGURE LC51AXB** 1 LC51CXB** 1 LC5AXB** 1 LC5CXB** 1 LC53AXB** LC83AXB** **RUS Listed ALUMINUM LC500 & LC800 FIGURE CONDUCTOR RANGE Notes: 1) For connectors without sealant, delete suffix XB. ) Add suffix GP for a tin-plated connector. 3) Plastic Cover Available. (See Type PTC Cover) INCHES #8 Sol. 1/0 Str. AAC #8 1/0 ACSR #8 Sol. 1/0 Str. AAC #8 1/0 ACSR #8 Sol. /0 Str. AAC #8 /0 ACSR #1 Sol. 400 MCM AAC # MCM ACSR #1 Sol. 400 MCM AAC # MCM ACSR MCM AAC MCM ACSR #8 Sol. # Str. AAC #8 # ACSR #8 Sol. # Str. Cu #8 Sol. 1/0 Str. AAC #8 1/0 ACSR #8 Sol. 1/0 Str. Cu #8 Sol. /0 Str. AAC #8 /0 ACSR #8 Sol. /0 Str. Cu #8 Sol. /0 Str. AAC #8 /0 ACSR #8 Sol. /0 Str. Cu #1 Sol. 400 MCM AAC # MCM ACSR #1 Sol. 400 MCM Cu #8 Sol. /0 Str. AAC #8 /0 ACSR #8 Sol. /0 Str. Cu GENERAL USE PARALLEL GROOVE ALUMINUM SINGLE CENTER BOLT WITH COPPER LINER 1-1/8 (8.58) 1-1/4 (31.76) 1- (34.93) 1- (38.1) 1-13/3 (35.7) 1-17/3 (38.89) 1-1/3 (4.07) -11/3 (51.60) -11/3 (59.53) -17/3 (64.9) 1- (38.10) -1/4 (57.15) - (63.50) - (69.85) 5/16 (8.0).14 (.06).19 (.09). (.10).8 (.13).41 (.19).54 (.4) FIGURE LC511AXB** 1 LC5AXB** 1 LC54XB 1 LC811AXB** 1 LC8XB LC833XB** **RUS Listed FIGURE 1 For aluminum to copper conductor connections only. Sealant (XB) is recommended on all connections. CONDUCTOR RANGE Body Aluminum Alloy Hardware Galvanized Steel Tap Liner Copper metallurgically bonded INCHES #6 Sol. 1/0 Str. AAC #8 1/0 ACSR #6 Sol. 1/0 Str. AAC #8 1/0 ACSR #6 Sol. 1/0 Str. AAC #8 1/0 ACSR #1 Sol. 400 MCM AAC # MCM ACSR #1 Sol. 400 MCM AAC # MCM ACSR MCM AAC MCM ACSR FIGURE #8 Sol. # Str. Cu #8 Sol. 1/0 Str. Cu 1/0 Str. 4/0 Str. Cu #8 Sol. 1/0 Str. Cu #8 Sol. /0 Str. Cu #8 Sol. /0 Str. Cu 1-1/8 (8.58) 1- (34.93) 1-3/16 (30.16) 1-1/4 (31.75) -1/4 (57.15) - (63.50) 1-5/16 (33.34) 1-1/3 (4.07) 1-5/3 (45.4) -1/3 (51.59) -7/3 (56.36) -17/3 (64.9) 1- (38.10) -1/4 (57.15) - (63.50) - (69.85) 5/16 (8.0).14 (.06). (.10).4 (.11).9 (.13).46 (.1).54 (.4)

19 GENERAL USE PARALLEL GROOVE ALUMINUM MULTIPLE CENTER BOLTS For aluminum to aluminum and aluminum to copper conductor splice/tap connectors. Sealant (XB) is recommended on all connections. ALUMINUM LC60/GA600 Notes: Body Aluminum Alloy Hardware Galvanized Steel 1) For connectors without sealant, delete suffix XB. ) Add suffix GP for a tin-plated connector. FIGURE 1 FIGURE FIGURE NO. CONDUCTOR RANGE INCHES GA670L 1 LC66AXB 1 LC67AXB 1/0 400 AAC 1/ (18/1) ACSR 1/0 (19) 400 MCM AAC 1/ (18/1) ACSR 1/0 400 AAC 1/ (18/1) ACSR 1/0 (19) 400 MCM AAC 1/ (18/1) ACSR 1/0 Sol. 400 MCM Cu 3-1/4 (8.71) 3- (88.90) 5-1/4 (133.35) -1/4 (57.6) - (60.44) - (66.80) - (69.85) - (69.85) - (63.5).60 (.7) 1.10 (.50) 1.30 (.59) 19 LC68AXB MCM AAC (18/1) 477 (30/7) ACSR MCM AAC (18/1) 477 (30/7) ACSR MCM Cu 5-1/4 (133.35) -13/16 (71.44) - (63.5) 1.90 (.86) GENERAL USE PARALLEL GROOVE ALUMINUM SINGLE U-BOLT ALUMINUM LC70 For aluminum to aluminum and aluminum to copper conductor splice/ tap connections and also aluminum or ACSR loop dead-ends. Sealant (XB) is recommended on all connections, except loop dead-ends. Body Top, spacer & bottom members Aluminum Alloy Hardware Galvanized Steel LC71B** LC7B LC73B LC74B** LC75B LC77B **RUS Listed CONDUCTOR RANGE INCHES #6 Sol. /0 Str. AAC #8 /0 ACSR #6 Sol. /0 Str. AAC #8 /0 ACSR 1/0 Sol. 400 MCM AAC 1/ MCM ACSR 1/0 Sol. 400 MCM AAC 1/ MCM ACSR MCM AAC MCM ACSR MCM AAC (45/7) ACSR #6 Sol. /0 Str. AAC #8 /0 ACSR #6 Sol. /0 Str. AAC #8 /0 ACSR #6 Sol. 1/0 Str. AAC #8 1/0 ACSR 1/0 Sol. 400 MCM AAC # MCM ACSR #6 Sol. 1/0 Str. AAC #8 1/0 ACSR MCM AAC (45/7) ACSR -1/4 (57.15) - (69.85) - (69.85) 3-1/4 (8.55) 3- (88.90) -1/4 (57.15) - (66.68) - (66.68) 3 (76.0) 3- (85.73) 3-1/4 (8.55) 3- (85.73) 4 (101.60) 4 (101.60) 4- (117.48) 5- (136.53) (15.88).43 (.0).77 (.35) 1.1 (.51) 1.1 (.55) 1.43 (.65) 1.97 (.89)

20 ALUMINUM LCU10 GENERAL USE PARALLEL GROOVE ALUMINUM TWO U-BOLT For aluminum to aluminum and aluminum to copper conductor splice/ tap connections. Sealant (XB) is recommended on all connections. Note: Body Top, spacer & bottom members Aluminum Alloy Hardware Aluminum Alloy For connectors without sealant, delete suffix XB. 0 LCU13XB LCU15XB LCU16XB CONDUCTOR RANGE INCHES 1/0 Str. 400 MCM AAC 1/ (18/1) ACSR MCM AAC MCM ACSR 1/0 Str. 400 MCM AAC 1/ (18/1) ACSR 1/0 Str. 400 MCM Cu 1/0 Str. 400 MCM AAC 1/ (18/1) ACSR 1/0 Str. 400 MCM Cu MCM AAC MCM ACSR MCM Cu 4-1/8 (104.78) 4- (117.48) 4- (117.48) -11/16 (68.6) 3-1/16 (77.79) 3-7/16 (87.31) 4- (114.30) 4-7/8 (13.83) 5- (139.70) (15.88) 1.07 (.49) 1.84 (.83) 1.86 (.84)

21 GENERAL USE PARALLEL GROOVE ALUMINUM 3 U-BOLT ALUMINUM LCU700 For aluminum to aluminum and aluminum to copper conductor splice/ tap connections. Sealant (XB) is recommended on all connections. Body Top, spacer & bottom members Aluminum Alloy Hardware Aluminum Alloy 1 LCU70055XB LCU70063XB LCU70064XB LCU70065XB LCU70066XB LCU70074XB LCU70076XB LCU70077XB LCU70085XB LCU70086XB LCU70087XB LCU70088XB LCU XB LCU XB LCU XB CONDUCTOR RANGE INCHES MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC ACSR MCM AAC MCM ACSR 4/0 Sol. 350 MCM AAC 3/ (18/1) ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR MCM AAC MCM ACSR 5-7/8 (149.3) 6- (171.45) 6- (171.45) 6- (171.45) 6- (171.45) 8 (03.0) 8 (03.0) 8 (03.0) 9- (31.78) 9- (31.78) 9- (31.78) 9- (31.78) 10 (54.0) 10 (54.0) 10 (54.0) 3-1/8 (79.38) 3-5/16 (84.14) 3-5/16 (84.14) 3-5/16 (84.14) 3-5/16 (84.14) 3-7/8 (98.43) 3-7/8 (98.43) 3-7/8 (98.43) 4-1/8 (104.78) 4-1/8 (104.78) 4-1/8 (104.78) 4-1/8 (104.78) 4- (111.1) 4- (111.1) 4- (111.1) 4-11/16 (119.06) 5-1/8 (130.18) 5-1/8 (130.18) 5-1/8 (130.18) 5- (139.70) 6 (15.40) 6 (15.40) 6- (161.93) 5- (146.05) 6- (161.93) 6- (161.93) 6- (161.93) 7 (177.8) 7 (177.8) 7 (177.8) (15.88) (15.88) (15.88) (15.88) (15.88) (19.05) (19.05) (19.05) (19.05) (19.05) (19.05) (19.05) (19.05) (19.05) (19.05).87 (1.30) 3.5 (1.47) 3.5 (1.47) 3.50 (1.59) 3.50 (1.59) 6.35 (.88) 6.50 (.95) 6.50 (.95) 8.50 (3.86) 8.50 (3.86) 8.75 (3.97) 8.75 (3.97) 7.85 (3.53) 7.85 (3.53) 6.85 (3.08)

22 /ALUMINUM SBS GENERAL USE SPLIT BOLT WITH SEPARATOR BAR: ALUMINUM AND For copper to copper conductors. Note: Copper Alloy, Electro Tin-Plated VERSA-SEAL oxide inhibiting compound is recommended for use with Al/Cu parallel connectors. * Hex Head design for maximum tool ease of use. LISTED 61L CONDUCTOR RANGE OF EQUAL MAIN & TAP (AWG OR MCM) MIN. TAP WITH INCHES MIN. MAX. ONE MAX. MAIN BOLT SIZE F W H SBS6 8 6* 14 7/16 SBS SBS /16 SBS10 4 1/ /16 SBS0 /0 8 SBS30 1 3/0 8 7/8 SBS SBS350 / /0 1- SBS /0 1- (15.88) 13/16 (0.63) 7/8 (.) 15/16 (3.81) 1-1/16 (6.97) 1-1/4 (31.75) 1- (34.93) 1- (38.01) 1- (44.45).49 (1.45).71 (18.03).75 (19.05).79 (0.07).87 (.10) 1.10 (7.94) 1.10 (7.94) 1. (30.99) 1.34 (34.04) 1.06 (6.9) 1.4 (31.5) 1.44 (36.58) 1.73 (43.94) 1.71 (43.43).13 (54.10). (56.39).56 (65.0).95 (74.93) 0.06 (.03) 0.09 (.04) 0.1 (.05) 0.18 (.08) 0.1 (.10) 0.35 (.16) 0.39 (.18) 0.60 (.7) 0.85 (.39) *AL9CU (90 C Rated) Not UL Listed or CSA certified for aluminum to copper connections. UL listed for copper connections only.

23 GENERAL USE SPLIT BOLT CONNECTOR SBN For copper to copper conductors. Body Copper Alloy LISTED 61L *Solid Conductor CONDUCTOR RANGE OF EQUAL MAIN & TAP (AWG OR MCM) MIN. TAP WITH INCHES MIN. MAX. ONE MAX. MAIN BOLT SIZE F W H SBN SBN6 8 6* 16 7/16 SBN SBN /16 SBN10 4 1/ /16 SBN0 /0 14 SBN30 1 3/0 8 7/8 SBN SBN350 / /0 1- SBN /0 1-9/16 (14.9) (15.88) 13/16 (0.63) 7/8 (.) 15/16 (3.81) 1-1/16 (6.97) 1-1/4 (31.75) 1- (34.93) 1- (38.01) 1- (44.45).47 (1).49 (1.45).71 (18.03).75 (19.05).79 (0.07).87 (.10) 1.10 (7.94) 1.10 (7.94) 1. (30.99) 1.34 (34.04) GENERAL USE PARALLEL GROOVE SINGLE CENTER BOLT For copper (Cu), Copperweld (CW) and guy strand (GS) connections..85 (1.59).91 (3.11) 1.16 (9.46) 1.5 (31.75) 1.54 (39.1) 1.69 (4.93).09 (53.09).09 (53.09).36 (59.94).83 (71.88) ST 0.04 (.0) 0.05 (.0) 0.08 (.04) 0.09 (.04) 0.14 (.06) 0.19 (.09) 0.30 (.14) 0.34 (.15) 0.51 (.3) 0.73 (.33) 3 Note: Body High Strength Bronze Alloy Hardware Silicon Bronze or Stainless Steel Add Suffix TP for Tin-Plated Version. ST3 ST4 CONDUCTOR RANGE (AWG) INCHES #8 Sol. /0 Str. Cu #8 A /0 F CW 1/8 7/16 CW/GS #6 Sol. 4/0 Str. Cu #6A 4/0 F CW 1/4 9/16 CW/GS #8 Sol. /0 Str. Cu #9 D /0 F CW 1/8 7/16 CW/GS #6 Sol. 4/0 Str. Cu #6A 4/0 F CW 1/4 9/16 CW/GS /8 (.) 15/16 (3.8) 1- (38.1) 1-7/8 (47.6) 1- (38.1) 1- (38.1) 5/16 (7.9) (9.5). (9.98).30 (13.61)

24 K, K_L GENERAL USE PARALLEL For copper to copper conductor connections. LISTED 61L Note: Body High Strength Bronze Alloy Retaining Ring Neoprene Rubber Hardware Silicon Bronze TP = Tin-Plated Version. 4 CONDUCTOR RANGE (AWG) INCHES K1 #4 Str. 1/0 Str. Cu #8 Sol. 1/0 Str. Cu K #3 Str. /0 Str. Cu #8 Sol. /0 Str. Cu K3 #1 Str. 4/0 Str. Cu #8 Sol. 4/0 Str. Cu K41 /0 Str. 350 MCM Cu #8 Sol. 350 MCM Cu K5 3/0 Str. 500 MCM Cu #8 Sol. 500 MCM Cu K MCM Cu #8 Sol. 800 MCM Cu K MCM Cu #8 Sol MCM Cu * For equal length bolts (Separable), Add L Suffix. For Tin-Plating, add TP Suffix - Consult Factory. KR 15/16 (3.81) 1-1/16 (6.99) 1-1/8 (8.58) 1- (34.93) 1- (38.10) 1- (41.8) 1-5/16 (33.34) 1- (41.8) 1- (44.45) -1/8 (53.98) -1/4 (57.15) - (63.50) 3 (76.70) GENERAL USE PARALLEL WITH SEPARATOR 1-5/16 (33.34) 1-1/3 (4.07) 1-15/16 (49.1) - (60.33) -11/16 (68.6) 3-3/16 (80.96) 3-11/16 (93.66) For copper to copper conductor connections. 5/16 (7.94) (15.88).15 (.06).9 (.13).40 (.18).655 (.30).80 (.36) 1.00 (.45).13 (.97) LISTED 61L Body High Strength Bronze Alloy Separator Copper Alloy Retaining Ring Neoprene Rubber Hardware Silicon Bronze CONDUCTOR RANGE (AWG OR MCM) INCHES KR1 #4 Str. 1/0 Str. Cu #8 Sol. 1/0 Str. Cu KR #3 Str. /0 Str. Cu #6 Sol. /0 Str. Cu KR3 #1 Str. 4/0 Str. Cu #6 Sol. 4/0 Str. Cu KR4 /0 Str. 350 MCM Cu #4 Sol. 350 MCM Cu KR5 3/0 Str. 500 MCM Cu #4 Sol. 500 MCM Cu KR MCM Cu # Str. 800 MCM Cu KR MCM Cu 1/0 Str MCM Cu * For equal length bolts (Separable), Add L Suffix. For Tin-Plating, add TP Suffix - Consult Factory. 15/16 (3.81) 1-1/16 (6.99) 1-1/8 (8.58) 1- (34.93) 1- (38.10) 1- (41.8) 1-5/16 (33.34) 1- (41.8) 1- (44.45) -1/8 (53.98) -1/4 (57.15) - (63.50) 3 (76.70) 1- (38.10) 1-5/3 (45.4) -1/8 (53.98) -9/16 (65.09) -15/16 (74.61) 3-7/16 (87.31) 4 (101.60) 5/16 (7.94) (15.88).18 (.08).35 (.16).43 (.19).78 (.35).86 (.39) 1.5 (.57).45 (1.11)

25 GENERAL USE PARALLEL GROOVE SINGLE U-BOLT LC1000 For copper to copper conductor connections. Body Halves High Strength Bronze Alloy Separator Copper Alloy Hardware Silicon Bronze * Add TP Suffix for Tin-Plated Connector CONDUCTOR RANGE (AWG OR MCM) For copper to copper conductor connections. INCHES LC100* # Sol. /0 Str. Cu # Sol. /0 Str. Cu LC1003* #1 Sol. 4/0 Str. Cu #1 Sol. 4/0 Str. Cu LC1004 1/0 Sol. 300 MCM Cu 1/0 Sol. 300 MCM Cu 1- (38.10) 1- (44.45) 1-15/16 (49.1) -5/16 (58.74) - 7/16 (61.91) GENERAL USE PARALLEL GROOVE U-BOLT - (69.85) 3 (76.0) 3- (88.90).65 (.9) 1.00 (.45) 1.15 (.5) LC Body Halves High strength Bronze alloy Separator Copper alloy Hardware Silicon bronze CONDUCTOR RANGE (AWG OR MCM) INCHES LC1133 #1 Sol. 4/0 Str. Cu #1 Sol. 4/0 Str. Cu LC /0 Sol. 350 MCM Cu 1/0 Sol. 350 MCM Cu LC1155 4/0 Sol. 500 MCM Cu 4/0 Sol. 500 MCM Cu LC MCM Cu MCM Cu LC MCM Cu MCM Cu - (69.85) 3-1/4 (8.55) 3- (85.73) 3- (9.08) 4 (101.60) 1-15/16 (49.1) - (63.50) - (66.68) -15/16 (74.61) 3-1/16 (77.79) 3 (76.0) 3- (9.5) 4 (101.60) 4- (114.30) 5 (17.00) 1.60 (.73).5 (1.0).40 (1.09).90 (1.3) 3.6 (1.64)

26 XP GENERAL USE PARALLEL GROOVE 4 WAY, /4 BOLT For copper to copper conductors cross, tee, parallel or end to end connections. Note: Body Members High Strength Bronze Alloy Separator Copper Alloy Hardware Silicon Bronze or Stainless Steel Add suffix TP for tin-plated connector. 6 LISTED 61L FIGURE 1 FIGURE FIGURE NO. CONDUCTOR RANGE (AWG OR MCM) INCHES XP #1 Str. 4/0 Str. Cu #1 Str. 4/0 Str. Cu XP /0 Str. 500 MCM Cu 4/0 Str. 500 MCM Cu XP MCM Cu 4/0 Str. 500 MCM Cu XP MCM Cu MCM Cu 1-7/8 (47.63) - (63.50) 1-7/8 (47.63) - (63.50) -9/16 (65.09) 3-3/16 (80.96) 3- (85.73) 3-11/16 (93.66).70 (.3) 1.40 (.64) 1.70 (.77).40 (1.09)

27 GENERAL USE PARALLEL GROOVE MULTIPLE CENTER BOLT LC400 For copper to copper conductor connections. Note: Body High Strength Bronze Alloy Hardware Silicon Bronze or Stainless Steel Add suffix TP for tin-plated Connector. FIGURE 1 FIGURE NO. FIGURE CONDUCTOR RANGE (AWG OR MCM) INCHES LC40 1 #4 Sol. 4/0 Str. Cu #4 Sol. 4/0 Str. Cu LC405 1 #4 Sol. 4/0 Str. Cu #4 Sol. 4/0 Str. Cu LC # Sol. 300 MCM Cu # Sol. 300 MCM Cu LC404 4/0 Str. 500 MCM Cu 4/0 Str. 500 MCM Cu LC MCM Cu MCM Cu -9/3 (57.94) -13/16 (71.44) 3-1/8 (79.38) 4- (111.13) 5-1/8 (130.18) 1-7/3 (46.83) -1/4 (57.15) - (66.68) 3- (88.90) -1/4 (57.15) -1/4 (57.15) -1/4 (57.15) - (66.68) 3- (85.73).8 (.37) 1.38 (.6) 1.79 (.81).99 (1.36) 4.70 (.13) 7 GENERAL USE PARALLEL GROOVE SINGLE CENTER BOLT LC1600 For copper to copper conductor connections. Note: Body High Strength Bronze Alloy Hardware Silicon Bronze or Stainless Steel Add suffix TP for tin-plated Connector. CONDUCTOR RANGE (AWG OR MCM) INCHES LC1601 1/0 Sol. 4/0 Str. Cu #8 Sol. #1 Str. Cu LC160 1/0 Sol. 400 MCM Cu #8 Sol. 3/0 Str. Cu - (60.33) 1- (44.45) -1/4 (57.15) - (69.85).58 (.6) 1.05 (.48)

28 SNAP TAP PLASTIC COVER PLASTIC PTC PTC Snap-on covers for aluminum compression taps. PTC51 & 5 Snap-on covers for mechanical center bolt taps. Black Plastic 8 PTC51 PTC PTC** DESCRIPTION For use on D die AC s or any H-frame connectors up to long, VCP-43A, VCP-44 VAC-1040 and VAC (.0318) **RUS Listed PTC51** For use on center bolt connectors LC-51A, LC-51C, LC5A, LC511A and LC-5A.05 (.036) PTC5** For use on center bolt connectors LC-5C, LC-81A, LC-811A, LC (.037)

Index GROUNDING CONNECTORS. TYPE WB Ground Rod Clamps. TYPE G/SRC Ground Rod Clamps. Heavy-Duty Clamps. Standard-Duty Clamps (Universal)

Index GROUNDING CONNECTORS. TYPE WB Ground Rod Clamps. TYPE G/SRC Ground Rod Clamps. Heavy-Duty Clamps. Standard-Duty Clamps (Universal) TYPE B Ground Rod Clamps Heavy-Duty Clamps GROUNDING CONNECTORS R30117 For direct burial. For connecting ground wire to driven rod. Designed to maintain proper alignment between ground wire and rod. Cast

More information

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products. Grounding BURNDY Products E-44 TYPE GRC HIGH STRENGTH GROUND ROD CLAMP For Copper Cable to Rod High copper alloy ground connector for joining a range of cable to copper clad, galvanized steel, and stainless

More information

Phone: Fax:

Phone: Fax: SEPTEMBER 2007 www.nsiindustries.com Phone: 800.321.5847 Fax: 800.841.5566 Mechanical Connectors Dual Rated Single & Double Lugs........................ 1 Panelboard Lugs............................ 1

More information

F4P lay-in lugs SERIES SPECIFICATION

F4P lay-in lugs SERIES SPECIFICATION F4P lay-in lugs SERIES SPECIFICATION Lay-in lugs are ideal for both grounding and continuous loop applications. Made of aluminum alloy and tin plated for low contact resistance, they are suitable for use

More information

OTHER DISTRIBUTION ONE PIECE WILDLIFE PROTECTOR

OTHER DISTRIBUTION ONE PIECE WILDLIFE PROTECTOR OTHER STRIBUTION ONE PIECE WILDLIFE PROTECTOR Designed to provide protection for equipment bushing from accidental contact by squirrels, birds or other wildlife. Hinged construction for easy installation

More information

QTY 7/374 8/346 11/375 12/348 17/298 18/324 19/ / /472 24/473 3 QTY

QTY 7/374 8/346 11/375 12/348 17/298 18/324 19/ / /472 24/473 3 QTY PAGE 20 BUTT SPLICES - COPPER Produced from high conductivity seamless copper tubing Marked with die index and color coded Tin plated to provide corrosion resistance SC SERIES Standard Barrel 5808 SC 8

More information

PART 4 ORANGE SECTION

PART 4 ORANGE SECTION PART 4 ORANGE SECTION BOLTED CONNECTORS BOLTED CONNECTORS 4-1 AERIAL CONNECTORS ALUMINIUM SERVICE TAP SL-4/12 SL-7/19 Conductor Range Run Diameter Tap Diameter 7/3.00 to 9mm to 7/1.75 to 7/4.75 14.3mm

More information

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14 SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

GROUNDING. Ground-Lok CLAMP SYSTEM SERRATED HEAD - (COMPONENTS)

GROUNDING. Ground-Lok CLAMP SYSTEM SERRATED HEAD - (COMPONENTS) PAGE 70 GREAVES EXCLUSIVE Ground-Lok CLAMP SYSTEM SERRATED HEAD - (COMPONENTS) BRONZE WATER PIPE CLAMPS Interchangeable clamps and adapters provide versatility Matching serrations assure positive lock

More information

Mechanical Connectors Product Overview

Mechanical Connectors Product Overview Product Overview......................... 40 Split-Bolt Connectors.................. 4-44 Service Post Connectors................ 4-46 Mechanical Service Entrance Connectors...... 4 Parallel Groove Connectors.............

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

Bolted Connectors & Terminals

Bolted Connectors & Terminals Disconnect Tee Connecr Type ADT5 75 Body 90 Nom. Function: ADT connecrs provide a convenient means of connecting lugged service conducrs overhead mains conducrs. Construction: Body - High strength cast

More information

SECTION GROUNDING

SECTION GROUNDING SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS SECTION 26 05 26 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide labor, materials, equipment, and incidentals as shown, specified, and

More information

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT

TEMPORARY PROTECTIVE GROUNDING EQUIPMENT TEMPORARY PROTECTIVE GROUNDING EQUIPMENT TEMPORARY PROTECTIVE GROUNDING EQUIPMENT NOTE: When ordeing assemblies of grounding products, please make sure all items included in the assembly are only from

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017 SECTION 27 05 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

New Product Flyer Introduction

New Product Flyer Introduction Dec. 5, 2013 New Product Flyer Introduction Preferred Lightning Protection, Inc. is excited to introduce our newest products and capabilities. Following are several new products with current inventories

More information

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building 2004 Specifications CSJ 0720-03-095 SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building 1. Description. Furnish and install Environmentally Controlled Communications Building

More information

ANDERSON HUBBELL POWER SYSTEMS FARGO

ANDERSON HUBBELL POWER SYSTEMS FARGO REFERENCE DATA ALUMINUM AND BRONZE CONNECTORS...-1 RECOMMENDED TYPES OF HARDWARE AND INALLATION MOUNTING... - AMPACITY RATINGS, BOLTED PAD CONNECTIONS...-5 CATALOG NUMBER SUFFIXES FOR SPECIAL FEATURES...

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

OVERHEAD SERVICES - SECONDARY

OVERHEAD SERVICES - SECONDARY OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

SECTION SIGNAL SYSTEMS MISCELLANEOUS PRODUCTS

SECTION SIGNAL SYSTEMS MISCELLANEOUS PRODUCTS SECTION 18360 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for miscellaneous components and products for signal systems. 1.02 REFERENCE STANDARDS A. American National Standards Institute

More information

Mechanical Connectors Product Overview

Mechanical Connectors Product Overview Product Overview......................... 40 Split-Bolt Connectors.................. 4-44 Service Post Connectors................ 4-46 Mechanical Service Entrance Connectors...... 4 Parallel Groove Connectors.............

More information

Table of Contents. Connector Manufacturing Co. US Page 1

Table of Contents. Connector Manufacturing Co.   US Page 1 Table of Contents 2AB2 15 2AB 15 2ABV 20 2BC 39 3AB2 17 3AB4 17 3ABV 20 4ABV 20 6ABV 20 A A1B2 13 A2B2 16 A3B2 18 A4B4 19 AB-50-S 11 AB-70-S 11 AB-112-R 12 AB-112S 11 AB-125-R 12 AB-125S 11 AB-250S 11

More information

A veteran-owned company

A veteran-owned company GALVAN Electrical Products Catalog galvanelectrical.com A veteran-owned company TAbLE of CoNTENTS by Product Category Ground Rods.................................... 6-9 Ground Plates & Ground Rod Driver...................

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers Design Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the American Standard Code for Pressure Piping. Hanger Design Pipe hangers are of advanced design

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

Mechanical Connectors

Mechanical Connectors Table of Contents Split-Bolt Connectors...A2A4 Parallel Groove Connectors...A5A7 Insulation Piercing Connectors... A8 Two-Bolt Connectors... A9A10 AMT Connectors... A11A13 ual-rated Mechanical Connectors...

More information

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION SECTION 16-372 SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION 1. GENERAL SPECIFICATIONS The work of this Section includes furnishing all labor, equipment, materials (unless specifically identified as Owner-furnished)

More information

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels. Threaded stud and

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels. Threaded stud and 1496-1497.qxp 12/16/2013 8:44 PM Page 1497 Cam-Lok J Series Connectors or NEMA 4 Cam-Lok J Series Connectors are specifically designed to meet the needs of demanding portable applications. J Series Plugs

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

SECTION FIELD PANELS

SECTION FIELD PANELS Stanford University Facilities Design Guidelines SECTION 25 14 23 FIELD PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section includes control panel and enclosure requirements for building control systems.

More information

Splices COOPER POWER SERIES. Connectors Catalog Data CA325007EN. Contents

Splices COOPER POWER SERIES. Connectors Catalog Data CA325007EN. Contents Connectors Catalog Data CA325007EN Supersedes March 2016 COOPER POWER SERIES Contents Description Page Single-tension sleeves... 2 Dual-tension sleeves... 2 Tension sleeves... 3 Jumper sleeves... 4 Bare

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

CHAPTER 13 GROUNDING AND BONDING

CHAPTER 13 GROUNDING AND BONDING GROUNDING AND BONDING CHAPTER 13 GROUNDING AND BONDING Grounding and bonding must be in accordance with Article 250 of the National Electrical Code (NEC). Bonding is defined in the NEC as the permanent

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Greenbook Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 08-15-17 Rev. #06:

More information

VERSAtile ALUMINUM COMPRESSION TERMINAL TYPE VCEL

VERSAtile ALUMINUM COMPRESSION TERMINAL TYPE VCEL VERSAtile UMINUM COMPRESSION TERMIN TYPE VCEL UMINUM VCEL For use with either VERSA-CRIMP or conventional compression tools For size-for-size replacements for original equipment set screw mechanical lugs,

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables. Issued 2005/06/01 Section 16122 Wire and Cables (0 1000V) Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 16151 Wire and Box Connectors 0 1000 1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods

More information

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry Expansion & Deflection Fittings SOLUTIONS for the Construction Industry TTINGS FI ST D LO C AF/AF8 SERIES e st d, in M a c h e d, As d in D e s i g n e d, b le the Casted Body with NPT hub size se m Ca

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

SECTION EARTHING AND EARTH FAULT PROTECTION

SECTION EARTHING AND EARTH FAULT PROTECTION SECTION 16660 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the construction and assembly of a complete electrical earthing

More information

Compression Grounding Copper E Crimps

Compression Grounding Copper E Crimps ELT Compression Grounding Copper E Crimps Manufactured from copper alloy Clearly marked with wire size and die index Range taking UL Listed and CSA Certified for grounding and bonding May be used in ground

More information

SECTION PART 1 GENERAL

SECTION PART 1 GENERAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Grounding of electrical systems and equipment and basic requirements for ground for equipment, circuits, and systems.

More information

SECTION FACILITY LIGHTNING PROTECTION

SECTION FACILITY LIGHTNING PROTECTION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 41 00 FACILITY LIGHTNING PROTECTION SPEC WRITER NOTE: Delete between //----//if not applicable to project. Also delete any other item or paragraph not applicable

More information

DISTRIBUTION TRANSFORMER SPECIFICATION #

DISTRIBUTION TRANSFORMER SPECIFICATION # DISTRIBUTION TRANSFORMER SPECIFICATION #1212.03 15kV Single Phase Submersible Transformer Stainless Steel 12/2/2011 Page 1 of 8 1. SCOPE This specification covers single-phase submersible transformers

More information

SECTION SECONDARY UNIT SUBSTATIONS

SECTION SECONDARY UNIT SUBSTATIONS SECTION 26 12 16 SECONDARY UNIT SUBSTATIONS PART 1 GENERAL 1.1 SUMMARY This section describes metal-clad, indoor or outdoor, secondary unit substations with integral primary fused disconnect switches,

More information

PRODUCT LINE TABLE OF CONTENTS. Blue highlighted items are industry standard and most frequently ordered.

PRODUCT LINE TABLE OF CONTENTS. Blue highlighted items are industry standard and most frequently ordered. BURNDY Overhead PRODUCT LINE TABLE OF CONTENTS TAP CONNECTORS Mechanical (Bolted)............ H-3 - H-17 Compression................ H-18 - H-37 Transformer and Equipment..... H-38 - H-40 COMPRESSION SPLICES

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS [OR WOOD] PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

Repair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL

Repair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL SECTION 16601 LIGHTNING PROTECTION SYSTEM PART 1 GENERAL 1.1 SCOPE A. Furnish and install all materials and labor required to provide a complete functional lightning protection and common ground system

More information

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS B-2 Performance The terminals and splices in this catalog are approved, per MIL-T-7928 and/or UL 486, where indicated. Table 1 shows the performance requirements for terminals used in military and commercial

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

RE: City of Claremore, OK, BH Substation Bid #SB Addendum #1 and Clarifications ( )

RE: City of Claremore, OK, BH Substation Bid #SB Addendum #1 and Clarifications ( ) January 28, 2013 TO ALL BIDDERS RE: City of Claremore, OK, BH Substation Bid #SB-2013-01 Addendum #1 and Clarifications (023515003) This letter is to provide Addendum #1 and Clarifications for the above

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

Unit Price Labor. INSTALL 138KV DISCONNECT SWITCH WITH MOTOR OPERATOR AND AUXILIARY SWITCHES ON EXISTING STRUCTURE 1 ea.

Unit Price Labor. INSTALL 138KV DISCONNECT SWITCH WITH MOTOR OPERATOR AND AUXILIARY SWITCHES ON EXISTING STRUCTURE 1 ea. SUBSTATION B UPGRADE CONSTRUCTION MAJOR MATERIAL NOTES: Contractor to fill in line item column "Est. Qty." for items left blank. Construction Unit No. Description Est. Qty. Unit Labor 100 INSTALL 138KV

More information

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products. H W U J B L T Substation Bolted TABLE OF CONTENTS COPPER SUBSTATION Introduction............... L-3 Type HFBW Bar Clamp............... L-13 Type NT Tube to Tube.............. L-4 Type HFB-P1 Bar Clamp...............

More information

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013. PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 26 0519 A. Single conductor building wire. B. Metal-clad cable. C. Wiring connectors. D. Electrical tape. E. Wire pulling lubricant. F. Cable ties. 1.2 RELATED

More information

Compression Connectors

Compression Connectors Table of Contents The Homac and lackburn brands by Thomas & etts provide compression connectors for wires ranging from # AWG to 500 kcmil. Choose from a vast array of dual-rated aluminum lugs, copper lugs,

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

56-SDMS-01 REV. 01 SPECIFICATIONS FOR 56-SDMS-01 REV. 01 SPECIFICATIONS FOR 13.8KV UNIT SUBSTATIONS This specification is property of SEC and subject to change or modification without any notice CONTENTS PAGE No. 1.0 SCOPE 3 2.0 CROSS REFERENCES

More information

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

TOWER & ANTENNA Product Catalog

TOWER & ANTENNA Product Catalog TOWER & ANTENNA Product Looking for Reliable Solutions to your Communications Network Needs? COMMUNICATIONS Product Fiber Optic, Copper, Demarcation, Bonding, Strand and Cable Solutions for the Communications

More information

CD Capacitor Discharge The Process

CD Capacitor Discharge The Process CD Capacitor Discharge The Process. CD. Capacitor Discharge Why CD Studs are better CD. Capacitor Discharge General Specifications Weld Base: CD. Stud Load/Torque Strengths Stud Material Stud Size Maximum

More information

GLENWOOD PLACE 2 MAR 2015

GLENWOOD PLACE 2 MAR 2015 PART 1 - GENERAL 1.01 SUMMARY: SECTION 16110 RACEWAYS A. Description: 1. Provide continuous conduit systems - beginning at the service point, to all distribution equipment and to every outlet and piece

More information

Flextray - Accessories

Flextray - Accessories Flextray - 40 Flextray - Protects cable from debris and dust Adds security to cable installation Easy bend-over tabs secure cover to trays Available for 2 (50mm) to 24 (600mm) wide trays Comes in 118 (2997mm)

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5 Thermal Solutions Worldwide SECTION C Industrial Thermocouples and RTDs Straight Base Metal Thermocouple Elements C1 Angle Base Metal Thermocouple Elements C2 Straight Noble Metal Thermocouple Elements

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

Bundling, Insulating and Sealing Products

Bundling, Insulating and Sealing Products Product Facts Plastic cable wrap provides an easy way to bundle cable, wire, tubing or hoses Helps protect bundles against abrasion caused by vibration Coiled wrap allows wiring harness breakouts Nylon

More information

Standard of Practice - Campus Electrical Distribution System

Standard of Practice - Campus Electrical Distribution System A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all

More information

SECTION CHAIN LINK FENCING

SECTION CHAIN LINK FENCING SECTION 02835 - CHAIN LINK FENCING 1.0 GENERAL 1.1 Furnish and install chain link fencing complete in place with gates and accessories as specified herein and as shown on the Contract Drawings. 1.2 Reference

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

Cutouts and Fuse Links Equipment to protect against faults and over-current conditions on power distribution systems. Open-Type Cutouts Linkbreak Cutouts Loadbreak Cutouts Cutout-Arrester Combinations

More information

SECTION OVERHEAD CONDUCTOR RAIL

SECTION OVERHEAD CONDUCTOR RAIL SECTION 34 23 06 OVERHEAD CONDUCTOR RAIL PART 1 - GENERAL 1.1 DESCRIPTION This Section describes and specifies the performance requirements to design, furnish, install, test, and place into satisfactory

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

600 GROUNDING 9/12/2018

600 GROUNDING 9/12/2018 00 GOUNDING //0 C N C N,N C N,N N TN0 C TN C TN C TN Installation of Grounding Assemblies Basic Units - Grounding Basic Units - Copperweld Grounding - Pole Ground epair Static Wire History/Policy Static

More information

Customer Owned Meter Enclosures for Self-Contained Watthour Meters

Customer Owned Meter Enclosures for Self-Contained Watthour Meters Revision No. 4 Page 1 of 15 SPECIFICATION Page 2 of 15 RECORD OF SPECIFICATION APPROVALS: This Specification is approved for the inclusion of subject products on the Florida Meter Group s Approved Metering

More information

04.00 GENERAL SECONDARIES & SERVICES SECONDARY AND SERVICE CABLE SPLICES INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 04.

04.00 GENERAL SECONDARIES & SERVICES SECONDARY AND SERVICE CABLE SPLICES INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 04. 4. GENERAL SECONDARIES & SERVICES 4.- TIE COLOR CODING 4.-6 SECONDARY AND SERVICE CABLE SPLICES 4.- INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 4.- 4. POLE ATTACHMENTS POLE ATTACHMENT DEVICES NEUTRAL

More information

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM) Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 03300 - Cast-in-Place Concrete.2 Section 05121 - Structural Steel for Buildings.3 Section 05500 - Metal Fabrications 1.2 REFERENCES.1

More information

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes. CHAPTER 35 SERVICES SECTION E3501 GENERAL SERVICES E3501.1 Scope. This chapter covers service conductors and equipment for the control and protection of services and their installation requirements. E3501.2

More information

TEMPORARY METER POLE INSTALLATION

TEMPORARY METER POLE INSTALLATION TEMPARY METER POLE INSTALLATION MEMBER PROVIDED Location to be made by REMC within 50' of our transformer or existing service Temporary pole to be properly braced 24" 3 wire weatherhead (located 24" from

More information

Section 5 Panels & Accessories

Section 5 Panels & Accessories Contents Section 5 Panels 74-76 Stiffener/Handle 79 Wire Mesh 75 Sliding Door Guide 80 Panel Mounting locks 77 Rolling Door Guide 81 Mesh Retainers 78 ifold Door Glide 82-83 Mesh Clamp 79 T-Clips 84 Panels

More information

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE The Contractors Choice the Contractors Choice Founded in 1958, with locations in Tulsa and Broken Arrow, Oklahoma. is part of the Quality Brands of Continental Industries. TABLE OF CONTENTS THE PROCESS...4

More information

Water & Industrial Products Catalog

Water & Industrial Products Catalog Water & Industrial Products Catalog www.smith-blair.com info@smith-blair.com Phone: 800..9705 or 870.77.527 After Hours Number: 90.277.998 Fax: 800.8.792 or 870.77.52 EMERGENCY PHONE 90.277.998 In the

More information

LIGHTNING PROTECTION SYSTEM EARTHING SYSTEM ELECTRICAL ACCESSORIES

LIGHTNING PROTECTION SYSTEM EARTHING SYSTEM ELECTRICAL ACCESSORIES LIGHTNING PROTECTION SYSTEM EARTHING SYSTEM ELECTRICAL ACCESSORIES AIR TERMINAL AIR TERMINAL FIXING BASE (flat) Material Aluminium / Copper Model Al-300-16 / Cu-300-16 Model Al-16 / GM-16 Diameter 16mm

More information

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section. Copyright 2016 Metal Roof Innovations, Ltd. www.s-5.com SECTION 26 31 00.01 PHOTOVOLTAIC COLLECTOR ATTACHMENT SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Photovoltaic Collector Attachment

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

onlinecomponents.com

onlinecomponents.com FSPDB FSPDB IP20 Finger Safe Power Distribution Block Reference Designation Nb. wire Nb. wire Materials Pckg inlets outlets X232803C FSPDB4A 335A 1/1 16 to 185mm 2 1x 185mm 2 to 16mm 2 1x 185mm 2 to 16mm

More information