Mechanical Connectors Product Overview

Size: px
Start display at page:

Download "Mechanical Connectors Product Overview"

Transcription

1 Product Overview Split-Bolt Connectors Service Post Connectors Mechanical Service Entrance Connectors Parallel Groove Connectors Insulated Conductor Connectors Two-Bolt Connectors Cross Tap Clamps/Dead End Clamps Hot Line Clamps Multi-Bolt Connectors AMT Connectors Copper Mechanical Connectors Anti-Rotational Connectors Dual-Rated Mechanical Connectors Miscellaneous Hardware Locktite Connectors Tap Connectors for Code Copper Conductors

2 Mechanical Connectors Product Overview Type H, HPS, HPW Copper Split Bolt Connectors Pages 4-42 Type APS, AAW, CA Aluminum Split Bolt Connectors Pages 4-44 Type SP Split Bolt Pages 4-46 Type N, NPW Service Entrance Connectors Page 4 Type MS Neutral Span Clamp Page 4 Blackburn ViceLock Page 48 Type PAC, PAE, PC, K Parallel Groove Connectors Pages 49- Type IPC Insulation Piercing Connectors Page 2 Type PT Insulated Phase Line Connectors Page 2 Type 2B, 2BX, 2BW Two-Bolt Connectors Pages -4 Type XT Cross Tap Clamp Page Type DLC Dead-End Clamps Page Type HLC, PGH Hot Line Clamps Page Type 4B, 6B Multi-Bolt Connectors Page AMT Connectors Page 8 Type L, TL Copper Mechanical Connectors Pages 9-60 Type S Copper Splice Page 60 Type STC, BTC Copper Mechanical Connectors Page 6 Type ADR Dual-Rated Mechanical Connectors Pages Type ASL Dual Rated Mechanical Connectors Pages 6-68 Type ASR Splicer Reducer Page 69 Type BX Rectangular Connectors Page 69 Type GP, GT Aluminum Parallel Tap Connectors Page 0 Type TC Insulating Covers Page Type BB, HN, SW Silicon Bronze Hardware Page 2 LOCKTITE Connectors Pages -80 Tap Connectors Page Thomas & Betts Corporation. Specifications are subject to change without notice.

3 Split Bolt Connectors or copper to copper connections. Bolt and nut of high strength corrosionresistant bronze alloy. Pressure bar is copper through 40H; copper alloy is used for 0 kcmil and above. Bolt and nut of hex design up to 0 kcmil. Tested and Listed to U.L. 486A requirements. Type H High Strength Split Bolt Connectors Conductor Range (AWG or kcmil) Range for Min. Tap Equal Main with One Dimensions (in.) Cat. No. and Tap Max. Main A B C D 9H 0 str. 2 sol. 4 sol H 8 str. 0 sol. 4 sol H* 8 str. 2 sol. 6 str H 6 sol. 8 sol. 4 sol H* 6 sol. 0 sol. 6 str H 4 sol. 8 sol. 4 sol H* 4 sol. 8 sol. 6 str H sol. 8 sol. 6 str H* 4 str. 8 sol. 6 str H 2 sol. 6 sol. 4 sol H* 2 sol. 6 sol. 4 sol H 2 str. 6 sol. 4 sol. 6.0 H** 2 str. 6 sol. 4 sol H /0 str. 4 sol. 4 sol H 2/0 str. 2 sol. 4 sol H 4/0 str. 2 sol. 6 sol H 20 kcmil str. 8 sol M 0 kcmil 20 kcmil /0 str M 00 kcmil 400 kcmil 2/0 str M 0 kcmil 600 kcmil 4/0 str M 000 kcmil 800 kcmil 4/0 str * Will accommodate wires of maximum size. ** Will accommodate #2 str. wires. The H bolts are not U.L. Listed or CSA Certified. U.L. recognizes solid and stranded conductor configurations for sizes #8 and smaller and stranded configurations only for sizes #6 and larger. Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 4

4 Mechanical Split Bolt Connectors Blackburn or use on copper, aluminum and ACSR conductors. Most connectors are U.L. Listed and CSA Certified for copper conductor only. Bolt and pressure bar of copper alloy completely tin plated. Contoured spacer of electrolytic copper up through 4/0; bronze alloy 0 and above, all tin plated. Blackburn Contax recommended when used on aluminum conductor. Type HPS Plated Split-Bolt Connectors with Spacer Conductor Range (AWG or kcmil) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Dimensions (in.) Cat. No. ACSR Copper or Aluminum A B C D 9HPS 0 str. 2 sol. 2 sol HPS 8 str. 2 sol. 2 sol HPS 8 6 sol. 2 sol. 2 sol HPS sol. 2 sol. 2 sol HPS sol. 8 sol. 8 sol HPS 2 8 str. 8 sol. 8 sol HPS 6 /0 str. 6 sol. 6 sol HPS /0 6 2/0 str. 6 str. 6 sol HPS 4/0 4 4/0 str. 4 sol. 4 sol HPS /0 0 kcmil /0 str. 2 sol HPS* 9. /0 00 kcmil /0 str. /0 str HPS* /0 0 kcmil 4/0 str. 2/0 str HPS* kcmil 00 kcmil 4/0 str * Not CSA Certified. U.L. 486A A or use on combinations of copper, aluminum and ACSR conductors. Bolt and pressure bar of high strength copper alloy completely tin plated; spacer and washer of electrolytic copper up through 4/0; bronze alloy 0 and above, all tin plated. Contoured spacer and bell mouth washer distributes pressure over large area of conductor. Large contoured spacer provides wide separation between copper and aluminum conductors. Blackburn Contax recommended when used with aluminum conductor. Type HPW Plated Split-Bolt Connectors with Spacer and Washer Conductor Range (AWG or kcmil) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Dimensions (in.) Cat.No. ACSR Copper or Aluminum A B C D 6HPW 8 6 sol. 2 sol. 2 sol HPW sol. 2 sol. 2 sol HPW sol. 8 sol. 8 sol HPW 2 8 str. 8 sol. 8 sol HPW 6 /0 str. 6 sol. 6 sol HPW /0 6 2/0 str. 6 sol. 6 sol HPW 4/0 4 4/0 str. 4 sol. 4 sol A D C B Thomas & Betts Corporation. Specifications are subject to change without notice.

5 Split Bolt Connectors Accommodates all aluminum and copper conductor combinations. 6 bolts cover the range from #0 to 4/0 AWG. Can be installed with standard wrenches. Corrosion resistant tin plated aluminum. Tested and listed to U.L. 486B, 90 C requirements. Type APS Aluminum Dual-Rated Split Bolts Conductor Range Dimensions (in.) Cat. No. Equal Main & Tap A B C D E APS str APS str APS str APS /0-4 str APS2 2/0-4 str APS4 4/0-2 str APS0* 0 kcmil-4 str APS00* 00 kcmil-2 str * Square head design not CSA certified Blackburn or all aluminum applications. Bolt, nut, pressure bar and contoured spacer of aluminum alloy. Large contoured spacer gives wide separation. Nut anodized to prevent thread galling. Blackburn Contax recommended when used on aluminum conductor. Type AAW Aluminum Split-Bolt Connectors with Spacer and Washers Conductor Range (AWG) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Dimensions (in.) Cat. No. ACSR Aluminum A B C D 6AAW sol. 8 sol. 0 sol AAW sol. 8 sol. 8 sol AAW 2 8 str. 8 sol. 8 sol. 6.0 AAW 4 /0 str. 2 sol. 4 sol AAW /0 4 2/0 str. 2 sol. 4 sol AAW 4/0 4 4/0 str. 4 sol. 4 sol Thomas & Betts Corporation. Specifications are subject to change without notice. 4

6 Split Bolt Connectors Blackburn Bolt, nut and washer of high-strength aluminum alloy; pressure bar and contoured spacer of electrolytic copper. Spacer is completely tin plated. Bolt and nut are anodized to prevent seizing of threads and reduce galvanic corrosion when in contact with copper conductor. Contoured spacer and bell mouth washer distributes pressure over large area of conductor. Blackburn Contax recommended with this Connector. Type CA Aluminum Split-Bolt Connectors with Spacer and Washer Conductor Range (AWG) Range for Min. Tap Equal Main with One and Tap Max. Main Dimensions (in.) Cat. No. Copper or Aluminum A B C D 6CA 4 sol. 6 sol. 4 sol. 2 sol CA 2 sol. 4 sol. 2 sol. 0 sol CA str. 4 sol. str. 8 sol. 6.0 CA /0 str. 2 sol. /0 str. 6 sol CA 2/0 str. 2 sol. 2/0 str. 6 sol CA 4/0 str. 2/0 sol. 4/0 str. 4 sol Thomas & Betts Corporation. Specifications are subject to change without notice.

7 Service Post Connectors Application The Blackburn line of Service Post Connectors is designed for applications including steel structure, fence post or transformer grounding involving one or two cables. Service Posts can also be used to tap one or two cables from bus bar. Construction and Ratings Bolts used in the Service Post are machined from high conductivity bronze alloy while the nuts are coldformed from high strength, corrosion resistant copper alloy. Pressure bars are copper through 4/0 size, while copper alloy is used for 0 mcm size and above. Bolts and nuts are of the traditional Blackburn hex design for easy installation. Service Post Connectors are available in sizes accommodating AWG copper conductor ranges of #2-00 kcmil stranded (4mm2-240mm2) and #2-#2 solid (4mm2-mm2). The line includes single conductor and double conductor connectors. or copper to copper connections. or grounding of steel structures, fence posts, transformers using one or two cables. or tapping one or two cables from bus bar. Hex design bolts are machined from high conductivity bronze alloy. Nuts and pressure bars are coldformed from high-strength copper or copper alloy. U.L. 486A and U.L. 46 Listed. Single and Double Conductor Short Stud Conductor Range AWG mm 2 Maximum Diameter Stranded Solid Range Cat. No. Dimensions (in.) max. min. max. min. (in.) SP-S SP-D Stud Size A AA B C D E SP0DS SP0SS 4 20 x 6 6 4mm 2 0mm 2 4mm SPDS SPSS 4 20 x 6 2 0mm 2 6mm 2 0mm 2 6mm SP2DS SP2SS 6 8 x 6 2 6mm 2 6mm 2 6mm 2 6mm SPDS SPSS 6 x mm 2 6mm 2 mm 2 6mm SP4DS SP4SS 6 x mm 2 6mm 2 mm 2 0mm 2 / SPDS SPSS x mm 2 mm 2 mm 2 2/ SP6DS SP6SS x mm 2 mm 2 mm 2 4/ SP8DS SP8SS x mm 2 mm 2 0 /0.-. SP9DS SP9SS x mm 2 0mm 2 00 / SP0DS SP0SS 4 0 x mm 2 9mm 2 Blackburn Single Conductor Short Stud Double Conductors Short Stud 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 4

8 Service Post Connectors Single and Double Conductor Long Stud Conductor Range AWG mm 2 Maximum Diameter Stranded Solid Cat No. Dimensions (in.) Range max. min. max. min. (in.) SP-S SP-D Stud Size A AA B C D E Blackburn SP0SL SP0DL 4 20 x 6 6 4mm 2 0mm 2 4mm SPSL SPDL 4 20 x 6 2 0mm 2 6mm 2 0mm 2 6mm SP2SL SP2DL 6 8 x 6 2 6mm 2 6mm 2 6mm 2 6mm SPSL SPDL 6 x mm 2 6mm 2 mm 2 6mm SP4SL SP4DL 6 x mm 2 6mm 2 mm 2 0mm 2 / SPSL SPDL x mm 2 mm 2 mm 2 2/ SP6SL SP6DL x mm 2 mm 2 mm 2 4/ SP8SL SP8DL x mm 2 mm 2 0 /0.-. SP9SL SP9DL x mm 2 0mm 2 00 / SP0SL SP0DL 4 0 x mm 2 9mm 2 Single Conductor Short Stud Double Conductors Short Stud Thomas & Betts Corporation. Specifications are subject to change without notice.

9 Mechanical Service Entrance Connectors Types N and NPW Service Entrance Connectors Conductor Range (AWG) ACSR Copper Dimensions (in.) Cat. No. max. min. max. min. A B C H Bolt Head Service entrance connectors with bodies and screws of high-strength copper alloy; NPW is tin plated. Type NPW has phosphor bronze washer, tin plated to protect conductor and distribute pressure. Type NPW can be used on ACSR conductor Slotted hex head screw. 0N 0NPW 0 str. 4 sol N 6NPW str. 0 sol N 4NPW str. 6 sol NPW str. 6 sol Type N A A Type NPW Washer on Type NPW only Blackburn Type MS Neutral Span Clamp Conductor Range ACSR AWG Cat. No. Main Tap Main Tap MS4 4/0 4 /0 6 4/0 str. 2 sol. /0 str. 6 sol. A combination aerial cable neutral parallel groove connector and dead-ending clamp that accommodates up to four service drops. Used in situations where house is not adjacent to pole. Taps may be installed later independent of existing connections. Castings are of high strength aluminum alloy; hardware is galvanized steel; one piece construction Thomas & Betts Corporation. Specifications are subject to change without notice. 4

10 Parallel Groove Connectors ViceLock NEW Blackburn GET A GRIP! With our new bronze vise type connectors that come in numerous sizes and offer a wide variety of features which will save you time and money. Blackburn Bronze ViseLock Connectors Create a superior electrical connection. Eliminate the need for costly or heavy tools. Install fast and easy. Make a permanent connection. Easily installed with live line tools. Advantages Vibration resistant. Easy to install without crossthreading. V-Grooves for easy conductor alignment. Increased bolt strength due to a full thread engagement design. The high pressure - torque ratio assures a low electrical resistance connection. Helps to reduce your inventory by accepting a wide range of conductors. Specification Information Bellcore Approved. Silicon Bronze material (CDA96000) for higher yield strength. Offer Stainless Steel hardware for large sizes. Superior Electrical Performance. ANSI Standards. ocus Applications Distribution Loads. Service Bonding. Tap Connections. Ground Connections. Also has a grounding capability with a variety of Cable Tray, Channel and Strut applications. Cross Reference Information Blackburn 2 Conductors Wire Range* Inner Ctn. Master Ctn. Competitor Cross Ref. Cat. No. Max. Min. Decimal (in.) Qty. Qty. ARGO RELIABLE VGC68 #6 SOL #0 SOL GC-006 BVC-6 VGC68SH #6 SOL #0 SOL GC-006SH VGC44 #4 STR. #8 SOL GC-004 BVC-4 VGC2 #2 SOL #6 SOL GC-002 BVC-2 VGC2 #2 STR. # SOL GC-002S BVC-2S VGC200 /0 STR. #4 SOL GC-020 BVC-20 VGC020 2/0 STR. # SOL GC-020S BVC-20S VGC4040 4/0 STR. # SOL GC-040 BVC-40 *Wire range indicates each connector s ability to accommodate two wires of the same size shown in the MAX or MIN columns Thomas & Betts Corporation. Specifications are subject to change without notice.

11 Parallel Groove Connectors Type PAA One and Two-Bolt Aluminum Parallel Groove Clamps or use on copper, aluminum and ACSR conductors. Order pre-filled with oxide inhibitor for use on copper to aluminum. Clamps are high-strength, heat treated cast aluminum alloy. Galvanized steel carriage bolt, nut and lockwasher are standard; for hex head bolts add suffix. PAA9 is extruded aluminum alloy, furnished with hex head bolt. Conductor Range Conductor Diameter Cat. No. Main Tap Main Tap Dimensions (in.) Bolt Standard Prefilled ACSR AL/CU ACSR AL/CU max. min. max. min. H L W Size PAA str. 6 sol str. 6 sol PAA9 /0 6 /0 str. 6 sol. /0 6 /0 str. 6 sol PAA4 PAA49 /0 6 /0 str. 6 sol. /0 6 /0 str. 6 sol PAA PAA9 /0 8 /0 str. 8 sol. /0 8 /0 str. 8 sol PAA6 PAA69 /0 8 2/0 str. 8 sol. /0 8 2/0 str. 8 sol PAA0 PAA /0 400 /0 str. /0 6 AR /0 6 AR /0 8 /0 str. 8 sol PAA2 PAA29 4/0 2 4/0 str. 2 sol. 4/0 2 4/0 str. 2 sol PAA400* PAA4009* 6.4 /0 400 /0 str. /0 6 AR /0 6 AR 6.4 /0 400 /0 str Blackburn * PAA 400 and 4009 are two bolt clamps. AR = Over armor rod RUS Listed. Cast PAA PAA9 Type PAC Aluminum Parallel Groove Clamps with Cast Copper Liner Aluminum body cast around pronged copper liner effectively seals out moisture. Corrosion resistant; copper conductor is in contact with copper aluminum conductor surrounded by aluminum; clamp provides wide physical separation of conductors reducing possibility of galvanic corrosion; aluminum bodies are pressure cast of corrosion resistant alloy; steel bolt and lockwasher are galvanized, and the nut is nickel plated. One piece construction; no loose parts to assemble during installation; copper inserts always face each other; carriage bolts urnished standard. or hex head bolt add suffix. Conductor Range Cat. No. Main Tap Conductor Diameter Dimensions (in.) Standard Prefilled ACSR AL Copper Main Tap H W L PAC4 # PAC49 /0 8 /0 str. 8 sol. /0 str. 8 sol / /0 str. PAC PAC9 /0 str. 8 sol /0 6 AR /0 6 AR RUS Listed Thomas & Betts Corporation. Specifications are subject to change without notice. 49

12 Parallel Groove Connectors Type PAE Parallel Groove Clamps, Extruded Type Extruded parallel groove clamps for use on aluminum to aluminum or aluminum to cop-per connections with oxide inhibitor. Tin plating (-P) or wax dip (-6) must be specified for without oxide inhibitor filled connectors. Standard PAE clamp is supplied with contax (-9) and galvanized steel hardware. Alll connectors can be installed with live line tools. Options: - Aluminum hardware -P Tin plating -6 Wax dip for oxide protection Example: Cat. Number for PAE 22 with Contax and aluminum hardware is PAE Blackburn Conductor Diameter (in.) Galvanized Aluminum Conductor Range Main Tap Dimensions (in.) Steel Bolt Bolt Cat. No. Main Tap max. min. max. min. ig. H W L B A Thd. Size. Thd. Size PAE /0 ACSR 6 sol. 6 AR 2/0 ACSR 6 sol. 6 AR UNC 6 UNC PAE /0 ACSR 2 sol. 4-6 AR 4/0 ACSR 2 sol. 4-6 AR UNC 6 UNC PAE ACSR /0 str. 2/0 str. 6 sol. 2/0 6 AR 6 AR UNC UNC PAE kcmil-9. 4/0 ACSR 2 sol. ACSR 6.4 2/0 AR 4-6 AR UNC UNC PAE ACSR /0 str. /0 ACSR 2 str. 2/0 6 AR 6 AR UNC UNC PAE ACSR /0 str. 9. ACSR /0 str. 2/0 6 AR 2/0 6 AR UNC UNC PAE kcmil 9. 2/0 str. 6 sol. ACSR 6.4 2/0 AR 6 AR UNC UNC PAE kcmil ACSR /0 str. ACSR 6.4 2/0 AR 2/0 6 AR UNC UNC PAE kcmil kcmil 9. ACSR 6.4 2/ AR ACSR 6.4 2/0 AR UNC UNC RUS Listed. ig. ig. 2 ig. ig. 4 ig. ig Thomas & Betts Corporation. Specifications are subject to change without notice.

13 Parallel Groove Connectors Type PC Two-Bolt Parallel Groove Clamp A copper alloy parallel groove clamp; hex head bolts with square shank of silicon bronze, spring washers also of silicon bronze. Square shank bolts prevent turning while tightening. Contour of casting permits use of socket wrench if desired. Large contact area increases conductance. No special tools required. Not recommended for aluminum conductor Conductor Range Conductor Diameter AWG or kcmil (in.) Main Tap A B Cat. No. max. min. max. min. max. min. max. min. PC20 20 str. 4 sol. 20 str. 4 sol f z 2j e c Blackburn Cast of high strength copper alloy. urnished with silicon bronze hex washer head bolt. Parallel groove design; no need to remove bolt for installation. Only one size for all requirements from No. 8 solid copper to /0 ACSR or 2/0 copper. Available plated, unplated or with plating in one groove. Type K Jumper Clamps Plated Groove Copper Groove Cat. No. Max. Min. Max. Min. K /0 ASCR 2 SCG amerductor 6 galv. strand 2/0 str. 6 ACSR copper 2SCG 6 amerductor Copperweld* 8 solid iron 2A Copperweld* 8 solid copper 9-2D Copperweld* etc. Plated with plating removed from one groove. or use with aluminum, amerductor, or galvanized steel strand to copper or copper bonded steel wires. Either Groove Cat. No. Max. Min. /0 ACSR 6 ACSR K2 2 SCG amerductor 2 SCG 6 galvanized amerductor steel strand 8 solid iron Clamp plated. or use with amerductor, aluminum, or galvanized steel stranding. Either Groove Cat. No. Max. Min. K 2/0 str. copper 6 copperweld* 2A copperweld* Clamp, not plated. or copper to copper connections. * Trademark of Copperweld. 8 solid copper 9 D copperweld* etc Thomas & Betts Corporation. Specifications are subject to change without notice.

14 Insulated Conductor Connectors Blackburn Performs as a splice or tap for non-tension applications up to 600 Volts depending on the size of the connector. Eliminates need for conductor insulation stripping. Self-insulated for hot line applications. No taping required after installation. or copper to copper, copper to aluminum and aluminum to aluminum applications. U.L. 486B Listed AL9CU (90 C rated). or use on insulated conductor only. Six connector line covers the range from #0-00 kcmil. Type IPC Talon Insulation Piercing Connectors AL or CU Conductor Range AWG/mm 2 No. Dimensions (in.) Cat. No. Main Tap Bolts ig W H L IPC02* / IPC4 4/0 /0 / IPC44 4/0 /0 4/0 / IPC04* / IPC 0 4/0 0 4/ IPC4 0 4/0 4/ * 600 Volt Rating (All others 00 Volt). ig. ig. 2 Type PT Insulated Phase Line Connectors Number Conductor Range of Main Tap Cat. No. Taps AWG ACSR AWG ACSR PT49 4 4/0 str. 2 str. 2/0 2 /0 str. 6 sol. 2-6 Takes up to 4 taps; taps may be added later without interrupting service or removing cover. Stainless steel hardware may be tightened with 9 6" wrench or with hexagonal Allen wrench, provided with each standard package. Impact resistant cover and clamp clearly marked with easy to read cable ranges. Extended insulating shields make cable stripping easier. Prefilled with Blackburn Contax Thomas & Betts Corporation. Specifications are subject to change without notice.

15 Two-Bolt Connectors Castings and bolts of high-strength copper alloy. Cap is removable; neoprene washers capture each bolt in bottom casting, aiding installation. U.L. 486A Listed for copper conductor only. Type 2B Two-Bolt Connector without Spacer Conductor Range (AWG or kcmil) Conductor Main Tap Diameter (B) Bolt Dimensions (in.) Cat. No. max. min. max. min. max. min. Head L H D 2B0 /0 str. 2 str. /0 str. 0 sol B20BB 2/0 str. 2 str. 2/0 str. 8 sol B40 4/0 str. /0 str. 4/0 str. 6 sol B0 0 kcmil 4/0 str. 0 kcmil 4 sol B00 00 kcmil 0 kcmil 00 kcmil 4 sol B kcmil 600 kcmil 800 kcmil 2 sol B kcmil 0 kcmil 000 kcmil 2 sol U.L. 486A Blackburn Type 2BX One-Piece Two-Bolt Connector without Spacer Conductor Range (AWG or kcmil) Conductor Main Tap Diameter (B) Bolt Dimensions (in.) Cat. No. max. min. max. min. max. min. Head L H D Castings and bolts of high-strength copper alloy. One piece construction. ree bolt is held in place with neoprene washer during installation. One extra length bolt allows top casting to swing free over two conductors of maximum range. U.L. 486A Listed for copper conductor only. 2B0X /0 str. 2 str. /0 str. 0 sol B20X 2/0 str. 2 str. 2/0 str. 8 sol B40X 4/0 str. /0 str. 4/0 str. 6 sol B0X 0 kcmil 4/0 str. 0 kcmil 4 sol B00X 00 kcmil 0 kcmil 00 kcmil 4 sol B800X 800 kcmil 600 kcmil 800 kcmil 2 sol B000X 000 kcmil 0 kcmil 000 kcmil 2 sol U.L. 486A Thomas & Betts Corporation. Specifications are subject to change without notice.

16 Two-Bolt Connectors Blackburn U.L. 486A Listed for copper conductor only. or use on copper conductors only. Castings and bolts of high-strength copper alloy; spacer of ductile, high-conductivity copper alloy. One-piece construction; contoured spacer is ringed and swings easily over the conductor. Type 2BW One-Piece Two-Bolt Connector with Spacer Conductor Range (AWG or kcmil) Conductor Diameter Main Tap A B Bolt Dimensions Cat. No. max. min. max. min. max. min. max. min. Head L H E 2B0W /0 str. 2 str. /0 str. 0 sol B20W 2/0 str. 2 str. 2/0 str. 8 sol B40W 4/0 str. /0 str. 4/0 str. 6 sol B0W 0 kcmil 4/0 str. 0 kcmil 4 sol B00W 00 kcmil 0 kcmil 00 kcmil 4 sol B800W 800 kcmil 600 kcmil 800 kcmil 2 sol B000W 000 kcmil 0 kcmil 000 kcmil 2 sol Type 2BPW One-Piece Two-Bolt Connector with Spacer Conductor Range (AWG or kcmil) Conductor Dia. Main Tap A B Bolt Dimensions Cat. No. max. min. max. min. max. min. max. min. Head L H E 2B0PW /0-2 /0-6 /0 str.-2 str. /0 str.-2sol /2 /6 /8 2B20PW 2/0-2 2/0-6 2/0 str.-2 str. /0 str.-2sol /2 /6 /8 2B40PW 4/0-/0 4/0-6 4/0 str.-/0 str. 4/0 str.-/0sol /6 2 /2 2 /8 2B0PW 0-4/ /0 0-4 sol /4 2 /8 2 /2 2B00PW sol /4 2 /4 2 /4 2B800PW sol /4 2 /2 /4 2B000PW sol /6 2 /2 /4 / /6 /6 /8 /2 /2 /2 /8 U.L. 486A Listed for copper conductor only. or use on copper, aluminum and ACSR conductors Thomas & Betts Corporation. Specifications are subject to change without notice.

17 Cross Tap Clamps/Dead End Clamps Type XT Clamp for Tee Tap, Cross, Parallel and End-to-End Connectors Conductor Range (AWG or kcmil) Conductor Diameter Main Tap A B Dim. (in.) Bolt Cat. No. max. min. max. min. max. min. max. min. L H W Size XT2 4/0 str. str. 2 str. 6 sol XT 4/0 str. str. 4/0 str. str XT2 00 kcmil 20 kcmil 2 str. 6 sol XT22 00 kcmil 20 kcmil 4/0 str. str XT2* 00 kcmil 20 kcmil 00 kcmil 20 kcmil XT* 000 kcmil 00 kcmil 00 kcmil 20 kcmil XT4* 000 kcmil 00 kcmil 000 kcmil 00 kcmil A multi-purpose connector; castings of copper alloy; bolts of silicon bronze. Design allows for free wrench rotation which speeds installation. or tin-plated style add suffix P to Cat. Number e.g. XT2P. * 4 bolt clamps 6 Blackburn Type DLC Single U Bolt Aluminum ittings Top and bottom pressure pads cast of high strength, heat treated, aluminum silicon alloy. Extra long separating spacer of highly conductive aluminum; spacer interlocks with U bolt will not drop out. Spring action counteracts cold flow. No special tools required for installation. Suitable for deadend loop connections. Hardware of high-strength galvanized steel. or use on copper, aluminum and ACSR conductors. Order pre-filled with oxide inhibitor (suffix 9) for use on aluminum to copper. Conductor Range Conductor Diameter ACSR AWG or kcmil A B Dimensions (in.) Cat. No. Main Tap Main Tap max. min. max. min. W L H E DLC206 2/0 6 2/0 6 2/0 str. 6 sol. 2/0 str. 6 sol DLC2 4/0 2 6 AR 4/0 / /0 str /0 str DLC2 6.4 /0 6.4 /0 /0 6 AR /0 6 AR 9. /0 str. 9. /0 str RUS listed 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

18 Hot Line Clamps Blackburn Eye-bolt coated with high temperature grease, assuring easy turning in all weather conditions. Available prefilled with oxide-inhibiting Contax and individually packaged; add suffix 9 to Cat. Number. HLC208 Series is for 2/0 8 main line conductor. HLC94 Series is for 9. kcmil 6 main line conductor. Type HLC Hot Line Clamps (Protected Thread) Conductor Range or Wire Main Tap Cat. No. Combination ACSR AWG or kcmil ACSR AWG Bronze Body Copper to HLC208 Copper 2/0 8 2/0 Plated Bronze General Body Purpose HLC208P 2/0 6 2/0 8 2/0 6 2/0 8 Plated Aluminum General Body Purpose HLC208AP9 2/0 6 2/0 8 2/0 6 2/0 8 Bronze Body Copper to HLC94 Copper sol. 4/0 6 sol. Plated Bronze General Body Purpose HLC94P sol. /0 6 4/0 6 sol. Plated Aluminum General Body Purpose HLC94AP sol. /0 6 4/0 6 sol. RUS Listed. Type PGH Center Bolt Parallel Groove Hot Tap Clamps Incorporates the superior design features of parallel groove clamps, time-proven for their reliable performance. Protected threads; wide temperature range lubricant prevents seizing. Tap wire positively secured to clamp during installation and removal by hex head bolt and pressure pad; main and tap clamped securely as clamp is tightened. Available prefilled with Contax, add suffix 9. Copper clamps are for use on copper conductors only. ig. ig. 2 ig. Conductor Range Conductor Diameter Center Dimensions Cat. No. Main Tap Main Tap Bolts (in.) Std. Pre-filled ACSR AWG ACSR AWG max. min. max. min. No. Dia. ig. W H L Aluminum Clamps PGH29 2/0 8 2/0 str. 8 sol. /0 8 /0 str. 8 sol PGH4 PGH /0 6 AR 40 4 sol. /0 6 4/0 str. 6 sol PGH / AR 000 4/0 str sol PGH629* 84 4/ AR 000 4/0 str sol Copper Clamps PGH PGH9 2/0 str. 8 sol. 2/0 str. 8 sol * PGH629 has two hex head bolt and pressure pad tap conductor retainers. AR-with Armor Rod Thomas & Betts Corporation. Specifications are subject to change without notice.

19 Multi-Bolt Connectors Types 4B, 6B One Piece Multi-Bolt Connectors Cap and pressure plate of cast aluminum alloy; spacer of high conductivity aluminum. High strength aluminum alloy bolts and lock washers prevent seizing. One piece construction eliminates loose parts during installation. or use on copper, aluminum and ACSR conductors. actory filled with Contax oxide inhibitor. Conductor Range Conductor Diameter No. ACSR AWG or kcmil A B Dimensions (in.) of Cat. No. Main Tap Main Tap max. min. max. min. W H T L E Bolts 4B29 4/0 4 4/ str sol B49 9. /0 9. /0 4 /0 str. 4 /0 str B Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

20 AMT Connectors NEW AMT Connectors The high quality and built-in flexibility of the new Blackburn AMT Connectors reduce the cost of field installations on splices, taps, and terminations. They re easy and quick to install, and provide superior insulation that lasts the life of the connection. eatures and Benefits: PVC insulation eliminates insulation failures and reduces outage costs. UV resistant material. Compact design provides space efficiencies. UL Listed. Blackburn Cat. No. Description ig. UPC Std. Ctn. AMTD0066 Insulated Six Hole Both Sides or 00-#6 AWG AMTD006 Insulated ive Hole Both Sides or 00-#6 AWG AMTD0064 Insulated our Hole Both Sides or 00-#6 AWG AMTD006 Insulated Three Hole Both Sides or 00-#6 AWG AMT00 Insulated Two Hole Same Side or 00-#6 AWG AMTD006 Insulated Six Hole Both Sides or 0-#0 AWG AMTD00 Insulated ive Hole Both Sides or 0-#0 AWG AMTD004 Insulated our Hole Both Sides or 0-#0 AWG AMTD00 Insulated Three Hole Both Sides or 0-#0 AWG AMTS006 Insulated Six Hole Same Side or 0-#0 AWG AMTS00 Insulated ive Hole Same Side or 0-#0 AWG AMTS004 Insulated our Hole Same Side or 0-#0 AWG AMTS00 Insulated Three Hole Same Side or 0-#0 AWG AMT0 Insulated Two Hole Same Side or 0-#0 AWG AMTS2008 Insulated Eight Hole Same Side or 20-#0 AWG AMTD2006 Insulated Six Hole Both Sides or 20-#0 AWG AMTD200 Insulated ive Hole Both Sides or 20-#0 AWG AMTD2004 Insulated our Hole Both Sides or 20-#0 AWG AMTD200 Insulated Three Hole Both Sides or 20-#0 AWG AMTT20 Insulated Two Hole Opposite Sides for 20-#0 AWG AMT20 Insulated Two Hole Same Side for 20-#0 AWG AMTS44 Insulated our Hole Same Side for #4-#4 AWG AMTTC4 Insulated Two Hole Opposite Sides for #4-#4 AWG AMTC4 Insulated Two Hole Same Side for #4-#4 AWG AMTT20 Insulated Two Hole Opposite Sides for 2/0-#4 AWG AMT20 Insulated Two Hole Same Side for 2/0-#4 AWG AMTSR00 Insulated Aluminum Splice 00-#0 AWG AMTSR0 Insulated Aluminum Splice 0-#6 AWG AMTSR20 Insulated Aluminum Splice 20-#6 AWG AMTSR0 Insulated Aluminum Splice /0-#4 AWG ig. ig. 2 ig. ig. 4 ig Thomas & Betts Corporation. Specifications are subject to change without notice.

21 Copper Mechanical Connectors Type L Single Conductor, One Hole Mount Cat. No. Conductor Range Dimensions (in.) Socket Hex max. min. L W H D J E G L* 8 str. 4 sol. 6 L0* 4 str. 4 sol L2 L2H /0 str. 8 sol L20 L20H 20 kcmil 6 str L400BB L400H 00 kcmil 4/0 str. L60 L60H 000 kcmil 00 kcmil Copper Mechanical Connectors or copper conductors. Screws are plated steel. Compact design. Add suffix P to cat. number for tin plating. One-piece construction for strength and durability. Excellent for confined quarters. Cat. Nos. L400 and L60 are cast from high strength bronze alloy. Cat. Nos. L, L0, L2 and L20 are cold forged from pure electrolytic copper with 99% conductivity. * Sizes L and L0 have screwdriver slot head screws only. U.L. 486A Blackburn Type L Single Conductor, Two Hole Mount Cat. No. Conductor Range Dimensions (in.) Socket Hex max. min. L W H D K E G J L22 L22H /0 str. 4 str L202 L202H 20 kcmil /0 str. 6 L4002 L4002H 00 kcmil 4/0 str. 6 L602 L602H 000 kcmil 00 kcmil U.L. 486A Cast from high strength bronze alloy. or use where large contact area is required to provide a more secure mounting Thomas & Betts Corporation. Specifications are subject to change without notice. 9

22 Copper Mechanical Connectors Type TL Two Conductor, Two Hole Mount Cat. No. Conductor Range Dimensions (in.) Socket Hex max. min. L W H D K E G J TL20 TL20H 20 kcmil /0 str TL400 TL400H 00 kcmil 4/0 str TL60 TL60H 000 kcmil 00 kcmil our hole NEMA tang on TL60. U.L. 486A Conveniently terminates parallel conductors. Blackburn Type S Copper End-to-End Splice Connector Conductor Range Dimensions (in.) Cat. No. max. min. L W H J I S00BB str. 4 sol. 6 6 S22BB* 4/0 str. str S400BB 00 kcmil 4/0 str * Not U.L. Listed. Cast of high strength copper alloy. Plated steel socket head set screws Thomas & Betts Corporation. Specifications are subject to change without notice.

23 Copper Mechanical Connectors Type STC Copper Single Conductor, One Hole Mount (Straight Tang) ig. Conductor Range Dimensions (in.) Cat. No. No. max. min. L W H E D STC04* 0 AWG 4 AWG 6 6 STC str. 4 AWG 9 6 STC str. 4 AWG STC str. 8 str. 4 STC02 /0 str. 2 str STC04 /0 str. 4 str Uniquely designed pressure bar and notched v-bottom collar provide a vise-like grip between conductor and terminal. U.L. 486A tested for copper conductor. Made of electrolytic seamless copper. Screws are zinc plated steel. STC402 4/0 str. 2 str. 2 2 STC 0 kcmil /0 str. 4 STC0 00 kcmil /0 str. 6 STC kcmil 600 kcmil 2 2 * Not CSA Listed. D W Blackburn E ig. ig. 2 ig. Type BTC Copper Single Conductor, One Hole Mount (Offset Tang) ig. Conductor Range Dimensions (in.) Cat. No. No. max. min. L W H E D BTC04* 0 AWG 4 AWG 6 4 BTC str. 4 AWG 2 BTC str. 8 str. 2 BTC02 /0 str. 2 str. 2 BTC04 /0 str. 4 str BTC402 4/0 str. 2 str BTC 0 kcmil /0 str. 4 2 BTC0 00 kcmil /0 str BTC kcmil 600 kcmil *Not CSA Listed E DIA. ig. ig. 2 ig Thomas & Betts Corporation. Specifications are subject to change without notice. 6

24 Anti-Rotational Connector NEW Anti-Rotational Connector Thomas & Betts new Anti-Rotational Connectors are designed with a rib on the bottom that keeps the connectors from turning, so there s no need to apply excessive torque and there s no danger of loosening connectors. The unique no turn rib provides a secure connection that eliminates conductor pinching that results from connector movement. The new no turn design feature solves a unique problem for electricians and installers. Larger conductors tend to get damaged in overtorque conditions, and connectors are prone to loosen in applications where there is vibration such as motor loads. Inspectors and local standards boards are requiring electricians and installers to make provisions to eliminate these conditions, and Blackburn Anti-Rotational Connectors are the solution. Blackburn Std./Outer Cat. No. Description Net Each Wt./00 UPC ig. ADR2-AR 2/0-4AWG, b Bolt Hole 2/ ig. ADR0-AR 00MCM-6AWG, k Bolt Hole 2/ ig. ADR-AR 0MCM-6AWG, j Bolt Hole 2/ ig. ADR60-AR 600MCM-2AWG, d Bolt Hole 6/ ig. ADR-2-AR 0MCM-6AWG, c Bolt Hole 6/ ig.2 ADR60-2-AR 600MCM-2AWG, d Bolt Hole 4/ ig.2 ig. ig Thomas & Betts Corporation. Specifications are subject to change without notice.

25 Dual-Rated Mechanical Connectors Type ADR ALCÜL Single Conductor, One-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G Slotted Screw ADR6 6 str. 4 AWG 4 4 ADR2 2 str. 4 AWG ADR /0 str. 4 AWG or copper and aluminum conductors. Easy installation no special tools required. Tin plated for low contact resistance. U.L. 486B tested, AL9CU Rated. All aluminum bodies. Slotted screw on lugs up through 2/0 str.; 6 socket screw on sizes 20 through 0 kcmil; c hex socket on sizes 00 kcmil and above. ADR2 2/0 str. 4 AWG Socket Screw ADR2 20 kcmil 6 str. 2 ADR0 00 kcmil 6 str. 2 ADR 0 kcmil 6 str ADR0 00 kcmil 4 str ADR kcmil 2 str kcmil 4 str. ADR6004* (2) 20 kcmil (2) /0 str ADR kcmil 00 kcmil 4 6 ADR kcmil 00 kcmil Blackburn * Not U.L. or CSA Listed. øe Bolt Hole W BKB CU9AL D L G H Type ADR ALCÜL Single Conductor, Two-Hole Mount* Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G ADR-2 # 0 kcmil 6 str ADR60-2D 600 kcmil 2 str. 6 ADR80-2D 800 kcmil 00 kcmil ADR99-2D 000 kcmil 00 kcmil * NEMA spacing: 4" centers # U.L. Listed. Connectors accommodating conductors 600 kcmil and larger have double row of set screws ( D suffix). E Bolt Size 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

26 Dual-Rated Mechanical Connectors Blackburn Type ADR ALCÜL Single Conductor, Switchgear Mount* Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G ADR2-2S 20 kcmil /0 str ADR-2S 0 kcmil 4 str ADR0-2S 00 kcmil 400 kcmil ADR80-2DS 800 kcmil 00 kcmil ADR99-2DS 000 kcmil 0 kcmil * NEMA Spacing: f" centers except ADR2-2S: " centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws ( D suffix). E Bolt Size Type ADR ALCÜL Two Conductor, One-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G I ADR-2 /0 str. 4 AWG ADR2-2* 2/0 str. 4 AWG ADR kcmil 6 str ADR-2 0 kcmil 6 str ADR kcmil 2 str ADR kcmil 00 kcmil ADR kcmil 00 kcmil * Not CSA Listed. U.L. 486B AL9CU E Bolt Size Thomas & Betts Corporation. Specifications are subject to change without notice.

27 Dual-Rated Mechanical Connectors Type ADR ALCÜL Two Conductor, Two-Hole Mount* Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G I ADR-22** 0 kcmil 6 str ADR60-22D 600 kcmil 2 str ADR80-22D 800 kcmil 00 kcmil ADR99-22D 000 kcmil 00 kcmil * NEMA Spacing: 4" centers. ** U.L. Listed. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B, AL9CU W L I G H Blackburn D f E Bolt Size Type ADR ALCÜL Three Conductor,Two-Hole Mount** Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G I ADR str. 4 AWG ADR-2 /0 str. 4 AWG ADR-2* /0 str.. 6 str ADR2-2* 20 kcmil 6 str ADR-2* 0 kcmil 6 str ADR0-2* 00 kcmil 4 str ADR60-2D 600 kcmil 2 str ADR80-2* 800 kcmil 00 kcmil ADR99-2* 000 kcmil 00 kcmil * U.L. Listed. ** NEMA Spacing: 4" centers except ADR02-2; centers and ADR-2; centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B, AL9CU E Bolt Size f 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

28 Dual-Rated Mechanical Connectors Type ADR ALCÜL Three Conductor, our-hole Mount** Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G I Blackburn ADR str. 4 AWG 2 6 ADR-4 /0 str. 4 AWG ADR-4 /0 str. 6 str ADR2-4* 20 kcmil 6 str ADR-4* 0 kcmil 6 str ADR0-4* 00 kcmil 4 str ADR60-4D 600 kcmil 2 str ADR80-4* 800 kcmil 00 kcmil ADR99-4* 000 kcmil 00 kcmil * U.L. Listed. ** NEMA Spacing: 4" centers except ADR02-4; " centers and ADR-4; " centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B AL9CU f E Bolt Size Type ADR ALCÜL Three Conductor, our-hole Mount* Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D E G I ADR kcmil 6 str ADR-44 0 kcmil 6 str ADR60-44D 600 kcmil 2 str ADR80-44D 800 kcmil 0 kcmil * NEMA Spacing: 4" centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). E f Bolt Size Thomas & Betts Corporation. Specifications are subject to change without notice.

29 Dual-Rated Mechanical Connectors Type ASL ALCÜL Two Conductor, One-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D Mtg. Hole Dia. ASL kcmil 6 str. 2 6 u DIA. i c Blackburn Type ASL ALCÜL Two Conductor, Two-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D ASL kcmil 2 str ASL kcmil /0 str U.L. 486B AL9CU i c c u DIA. 2 HOLES 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

30 Dual-Rated Mechanical Connectors Type ASL ALCÜL Three Conductor, Two-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D I ASL kcmil 2 str ASL-2 0 kcmil /0 str Blackburn i u DIA. 2 HOLES c Type ASL ALCÜL our Conductor, Two-Hole Mount Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H D I ASL kcmil 2 str ASL-42 0 kcmil /0 str i c u DIA. 2 HOLES Thomas & Betts Corporation. Specifications are subject to change without notice.

31 Dual-Rated Mechanical Connectors Type ASR ALCÜL Splicer Reducer with Solid Barrier Wire Stop Conductor Range (AL or CU) Dimensions (in.) Cat. No. max. min. L W H I ASR024* 2 str. 4 AWG ASR4* /0 str. 4 AWG 9 2 ASR kcmil 6 str. 2 ASR06 0 kcmil 6 str. 2 4 ASR2** 0 kcmil 20 kcmil * Slotted screws ** Two set screws per end. Not CSA Certified. U.L. 486B AL9CU W L I H Blackburn Type BX ALCÜL Rectangular Connectors Conductor Style & Boss Range Size of Hole Dimensions (in.) Cat. No. max. min. Boss Tapped L W H BX CU Square 2AL.229 in BX4 /0 4CU Square 2AL.229 in Recognized component in accordance with U.L. 486B standard 90 C rating. Anti-rotational boss Thomas & Betts Corporation. Specifications are subject to change without notice. 69

32 Dual-Rated Mechanical Connectors Type GP Aluminum Dual Rated Mechanical Connectors Parallel Tap Connectors Conductor Range (AL or CU) Dimensions (in.) Cat. No. Main Tap W L H Blackburn GP-2* 2 2 str. 4 4 GP-0 /0 2 / GP /0 / GP / GP-0 0 4/ GP GP GP /0 4 2 * Slotted screw, tap side. To include insulating cover add suffix WC. No cover available for GP-0-. Type GT Aluminum Dual Rated Mechanical Connectors Parallel Tap Connectors Conductor Range (AL or CU) Dimensions (in.) Cat. No. Main Tap W L H GT-2* 2 2 str. 4 4 GT-0 /0 2 / GT /0 / GT / GT-0 0 4/ GT GT * Slotted screw, tap side. To include insulating cover add suffix WC Thomas & Betts Corporation. Specifications are subject to change without notice.

33 Dual-Rated Mechanical Connectors Type TC Insulating Covers for GP-GT Dimensions (in.) Use with Cat. No. Colour L W H Connector TC-2 Yellow GP-2, GT-2 TC-0 Grey GP-0, GT-0 TC-20 Red 2 9 GP-20, GT-20, GP-20-0, GT-20-0 TC-0BB Yellow 2 2 GP-0, GT-0 TC-00 Blue GP-00, GT-00 TC-0 Orange 4 2 GP-0, GT-0 Blackburn Tightening Torque Values for Aluminum Dual Rated Socket Screw Connectors AWG or AWG or Circular Tightening Torque in in-lb Circular Tightening Torque in in-lb Mil Size Screw Driver Wrench Mil Size Screw Driver Wrench / / / / Thomas & Betts Corporation. Specifications are subject to change without notice.

34 Miscellaneous Hardware Blackburn or tin-plated silicon bronze hardware, add suffix P to Cat. Number. Bolts 2" long or less have full thread; longer bolts have 2" of thread, except b" 20 bolts have b" min. thread. Type BB Silicon Bronze Hardware Hex Head Bolts Cat. No. Length Diameter and Threads per inch (in.) b" 20 j" 8 c" 6 d" 200BB 00BB 00BB 000BB 4 2BB 2BB 02BB 4 0BB 0BB 00BB 4 BB BB 0BB 2 200BB 200BB 0200BB BB 22BB 22BB 022BB 2 20BB 20BB 020BB 2 4 2BB 2BB 02BB 00BB 00BB 000BB 4 2BB 02BB 0BB 00BB Type HN Bronze Hex Nuts Diameter Cat. No. and Threads per inch 400HN HN HN 6 000HN Type SW Bronze Split Lockwashers Cat. No. Bolt Size (in.) 400SW 4 00SW 6 00SW 000SW Type W Bronze lat Washers Bolt Sizes O.D. I.D. Thickness Cat. No. (in.) (in.) (in.) (in.) 4040W W W W Type BW Belleville Washers 02 Series Stainless Steel Bolt Size O.D. I.D. Thickness Height Cat. No. (in.) (in.) (in.) (in.) (in.) 000BW Thomas & Betts Corporation. Specifications are subject to change without notice.

35 LOCKTITE Connectors Code Copper Conductor (for 600V) Each standard one-hole lug fits many sizes of copper cable, thus only nine lug sizes are required to accommodate all cables from #4 to 000 kcmil. Easily installed with a key wrench. Saddle and cable socket make direct, all around, low resistance contact with cable. Convenient peep hole permits easy inspection. One-Bolt Hole Cable Dimensions (in.) Cat. No. Size G A B C D J 00 4 to 8 d a l d a w s 00 8 to 4 d a e d a w s 00 4 to d e m e r X 009 to 2/0 c n m b i k 0 2/0 to 4/0 c 2c b s u w 0 4/0 to 00 d 2f d i j w e 0 00 to 00 d h L c X m f 0 00 to 0 d A 2i e u 2a 09 0 to 000 e 4j 2v g v 2X i With ilister Head Screw. All others, hex socket screws. G Bolt Size C Blackburn J B D A One-Bolt Hole lag Type Cable Dimensions (in.) Cat. No. Size G A B C D J E 00-AL 8 to 4 b a e d a w s d With ilister Head Screw Bolt holes and spacings listed are standard, but lugs with blank tongues can be furnished. or torque requirements see page C. G Bolt Size E C A J B D 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

36 LOCKTITE Connectors Code Copper Conductor (for 600V) Blackburn The outstanding LOCKTITE lug features of easy installation, high conductivity and wide cable range are available in this lug with a long tongue adapted for two bolts. G Bolt Size H C One-Bolt Hole 90 Upright Cable Dimensions (in.) Cat. No. Size G A B C D J 00-UAL 8 to 4 b a e d a d s 00-UAL 4 to b y m e r m X 009-UAL to 2/0 c 2o m b n k 0-UAL 2/0 to 4/0 c 2d b s a w With ilister Head Screw. All others, hex head screws. Bolt holes and spacings listed are standard, but lugs with blank tongues can be furnished. Two-Bolt Hole Cable Dimensions (in.) Cat. No. Size G A B C D J H to 8 b L b d a v s e to 4 b f b d a w s e to b 2b k e r g s f 2009 to 2/0 c 2g n m b u k 20 2/0 to 4/0 c a 2 s n k 20 4/0 to 00 c c 2a i j l k to 00 c d 2a c X B k to 0 d 4x f u 2a l d to 000 d 4B g v 2X l d With ilister Head Screw. All others, hex head screws. or torque requirements see page C. J B D A These two-hole lugs are furnished with bolt holes and spacings to fit equipment supplied with NEMA type connector mounting pads. G Bolt Size H C Two-Bolt Hole NEMA Drilled Cable Dimensions (in.) Cat. No. Size G A B C D J H to c 2m 2 f r g k 2209 to 2/0 d n b L l f 22 2/0 to 4/0 d 4a s s l f 22 4/0 to 00 d 4i i j v l f to 00 d 4g d c X m l f to 0 d p d f u 2a l f to 000 d b d v 2a l f or torque requirements see page C. J B D A Thomas & Betts Corporation. Specifications are subject to change without notice.

37 LOCKTITE Connectors Code Copper Conductor (for 600V) Double and triple barrel LOCKTITE lugs have same features as single barrel: screw tightening, serrated saddle, built-in lock washer. Double Barrel/Triple Barrel NEMA Drilled 600V Applications Cable Dimensions (in.) Cat. No. Size ig. G A B C D E H J 200BD 4 to 8 A b 2i f e a L s e v 200BD 8 to 4 A b 2d 2 a s e w 200BD 4 to A c 2m 2 b r b k C 2009BD to 2/0 A d 4k d d b l e f u 20BD 2/0 to 4/0 A d 4e d f s f e f n 20BD 4/0 to 00 A d 4f d 2 j 2a e f l 20BD 00 to 00 A d c n 2d X 2d e f m 20BD 00 to 00 B d x 4 4 u 2n e f 2a 209BD 0 to 000 B d B 4 4 v b e f 2X 20TB 2/0 to 4/0 C d 4e c 2d s 2f e f n 20TB 4/0 to 00 C d 4f d j b e f w 20TB 00 to 00 D d c 4 4 X f e f m 20TB 00 to 0 D d x 4 4 u 4c e f 2a 209TB 0 to 000 D d B 4 4 v 4m e f 2X With ilister Head Screw or torque requirements see page C. Bolt Size Bolt Size Blackburn E C E H C A B H A B H J D J D ig. A ig. B Bolt Size Bolt Size E C E H C A B H A B H J D J D ig. C ig. D 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

38 LOCKTITE Connectors Code Copper Conductor (for 600V) Blackburn Two-way connectors join two cables end to end. Cables are held by saddle, tightened by screws. Lock washers are built in. Two-Way Connectors Cable Dimensions (in.) Cat. No. Size A E J 20 4 sol. to 8 sol. a c v 20 8 sol. to 4 str. c d w 20 4 sol. to str. e e B 209 sol. to 2/0 g f o 2 2/0 to 4/0 2j n b 2 4/0 to 00 2l a d 2 00 to 00 2f b A 2 00 to 0 a d 2h 29 0 to 000 g L 2s With ilister Head Screw or torque requirements see page C. A E J These taps are designed for one-man installation. Tap hangs on main while the branch is being inserted and the screw tightened. Tee-Parallel Taps Cable Size Dimensions (in.) Cat. No. Main Branch A B C 0 00 to 00 2 to /0 2d f b 0 4/0 to 00 h g e 0 2 to /0 2m n b 0 00 to 0 4/0 to 00 c 2h e to 0 4 2h 2h or torque requirements see page C. C B A Thomas & Betts Corporation. Specifications are subject to change without notice.

39 LOCKTITE Connectors Code Copper Conductor (for 600V) or stranded, solid, flexible and other types of cables, each lug takes a range of wire sizes. Bolt holes and spacings listed are standard, but lugs with blank tongues will be furnished, if specified, without extra charge. Tandem Type Two-Bolt Hole NEMA Drilled Cable Dimensions (in.) Cat. No. Size G A B C D J H 200TL 4 to c l 2 f r C k 2009TL to 2/0 d 4n b p l f 20TL 2/0 to 4/0 d c s j l f 20TL 4/0 to 00 d e i j l l f 20TL 00 to 00 d 6X d c X e f 20TL 00 to 0 d 6z d f u 2a e f J G Bolt Size H B C D Blackburn A Ground Bus Taps for 4" Copper Bus Bar or easy installation in hard-to-reach places, these bar taps eliminate the necessity of drilling holes in the ground bus. They can be placed quickly at any location, and the only installing tool is a key wrench. A standard LOCKTITE lug grip securely holds the tapping cable. Wire Size Dimensions (in.) Cat. No. (in.) A B Bus Thickness 20 8 to 4 2b f b to 2l f b 209 to 2/0 2f f b 20 2/0 to 4/0 2f f b 2 4/0 to 00 2g f b to 00 f b or torque requirements see page C. B A 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

40 LOCKTITE Connectors Code Copper Conductor (for 600V) * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-0 and 0-8 code sizes. Pigtail Connectors Cable Dimensions (in.) Cat. No. Size ig. A J 0 0 to 8 A d w 0 8 to 6 B f B 09 6 to 4 B g o 4 to 2 B h b to 2/0 B i d 2/0 to 4/0 B j A or torque requirements see page C. Blackburn A J ig. A ig. B Stud Connectors Each connector will accommodate a wide range of conductor sizes. Installation is simple and the convenient pigtail is easy to tape. * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-0 and 0-8 code sizes. Type MS Cable Dimensions (in.) Stud Cat. No. Size G A B D E Size (in.) 00-T 4 to c 6 c A g e f c T to 2/0 c 6 e g f f c 6 0-T 2/0 to 4/0 d e h i g d 0-T 4/0 to 00 d g i c h d 0-T 00 to 00 d 2q j d b d E B A D Thomas & Betts Corporation. Specifications are subject to change without notice.

41 LOCKTITE Connectors Code Copper Conductor (for 600V) Standard tapping is shown in diagrams. Other tapping can be furnished for specific requirements. * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-8 and 8-4 code sizes. Stud Connectors (continued) emale Type L Cable Dimensions (in.) Stud Cat. No. Size ig. G A B Size (in.) 26 4 to 8 A c 6 p e c to 4 A c 6 h e c to B c 6 v f c to B d v f d 26 2/0 to 4/0 B d 2i m d With ilister Head Screw A G B A G B Blackburn ig. A ig. B T&B Recommended Tightening Torque Screw Size of Wrench Driver Conductor Torque Torque Ranges in.-lbs. in.-lbs. 4 to to 4 4 to 2 to 2/0 0 2/0 to 4/ /0 to to to to Thomas & Betts Corporation. Specifications are subject to change without notice. 9

42 LOCKTITE Connectors Code Copper Conductor (for 600V) LUG-IT connectors are designed to grip the cable firmly between the strong body and the serrated copper tongue. Double laps at the top give greater thread strength and lock the screw when it is tight. The copper tongue makes a low resistance terminal. LUG-IT Lugs One Hole, Offset Tongue Cable Dimensions (in.) Cat. No. Size G A B C D 0 4 to 6 #0 i d c.064 r 40 8 to 2 b k e d.08 b *0 4 to 2/0 b m m f.0 c *60 /0 to 4/0 c 2w p.28 d * Aluminum body Hex head bolt Add suffix G to above Cat. No s for lug connector with green screw for grounding identification. or torque requirements, see page C. Blackburn B C A D Cone Screw Lugs Wire Dimensions (in.) Torque Cat. No. Range G A B C D E (in.-lbs.) The conically shaped screw compresses the copper conductor so that each strand is forced to carry its own share of the load. Equal pressure is exerted on each conductor strand and the cone screw assures high pull-out and low resistance #0 m k c p c i 20 * b q e l a x s * /0 c y B z i A c /0 c g C n i O c c 2o C r c /0-00 d 2f b X s v l 00 Add suffix G to lug Cat. No. 00, 00, 00, and 04 for lug with green screw for grounding identification. U.L. ile No. E-9609 *Indicates screwdriver torque; all others indicate torque wrench. G Bolt Size C B A D E Thomas & Betts Corporation. Specifications are subject to change without notice.

43 Tap Connectors for Code Copper Conductor HINJON Junior taps are the most economical, easiest to install, approved connector for large to small branch taps. Jaws with all-around-grip automatically adjust to size of main and branch. ast, simple installation is accomplished with screw driver or pliers and fitting is easily taped. HINJON Junior Tee-Parallel Taps Cable Size Dimensions (in.) Cat. No. Main Branch A B C 0 8 to 4 4 to 8 h g e 09 4 to /0 4 to 4 b L /0 to 4/0 4 to 4 f c B 2 8 to e l B 00 to 00 4 to 4 g m B max. A max. C T&B Recommended Tightening Torque Size of Wrench Screwdriver Conductor Torque Torque Ranges in.-lbs. in.-lbs. 4 to to 4 4 to 2/0 0 2 to 4/0 200 to /0 to Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 8

44 Blackburn Thomas & Betts Corporation. Specifications are subject to change without notice.

45 Grounding Product Overview E-Z Ground Grounding Connectors Grounding Connectors E-Z Ground Compression Connectors , 9-99 Cast Copper Connectors for Grounding , 00 Ground Rod Clamps and Ground Rod Accessories , 06 Ground Clamps Ground Plates Mechanical Grounding Connectors Grounding Conduit Hubs lexible Braid lexible Braid Selection Guide Grounding Accessories

46 Grounding Grounding Connectors and Accessories Product Overview igure 6 Page 8 igure 8 Page 8 igure 6-6 Page 88 igure 6-8 Page 88 C-Taps Page 89 Blackburn C-Crimp Page 89 Type GR Pigtail Connectors Page 90 Grounding Studs Page 9 I-Beam Page 92 Two Way Connector Page 92 Grounding Plate Page 9 Ground Bus Bar Connector Page 9 Snap Tap Connector Page 96 Type GRD, GG Ground Grid Connectors Pages 9-00 Type GG, GGH, JAB, G Ground Rod Clamps Pages 0-02 Type DGC Drive-on Ground Clamps Page Type GUV U-Bolt Ground Clamps Page 0 Ground Electrode Boxes Page 0 Sectional Ground Rod Couplings Page 06 Ground Plate Page 0 Type GTC Tower Ground Clamps Page 08 Parallel Connectors Page 09 Type SP Service Post Connectors Pages 09-0 Type TTC Transformer Tank Grounding Connector Page 0 Cast Bronze Ground Clamps Pages -4 Type CH Conduit Hubs Page Type B lexible Braid Connectors Pages 6- Metallic Gradient Control Mat Page 8 Type J lexible Ground Clamp Page Thomas & Betts Corporation. Specifications are subject to change without notice.

47 Grounding E-Z Ground Grounding Connectors Compression Method Grounding Connectors Save 0-% In Time and Labor Costs This installation method results in a long lasting low installed cost connection. You can install it and forget it. Before compression, typical cable connector cross section of cable and connector consists of about % metal and 2% air. After Thomas & Betts method compression, the cross section shows 00% metal with virtually no air spaces. Thomas & Betts introduces a method of compression to replace exothermic welding and its associated disadvantages. This compression method is designed to provide quick, reliable connections for grid grounding at significantly lower installed costs since compression connectors install in less time, in any weather, and are unaffected by moisture, reducing downtime. In addition, our compression connectors for grid grounding require no special training for installation. They are made of high conductivity wrought and cast copper, and are used for connecting and tapping cross grid, loop lines, and ground rods for direct burial or concrete embedded ground grid systems. The Thomas & Betts compression system uses standard electrical connector installation tools. Eliminates exothermic welding. Reduces labor and labor costs. Minimize possibility of poor connections. Meets all applicable specifications Thomas & Betts grid and ground rod connectors satisfy the requirements of NEC 20-0 for connecting to the Grounding Electrode System. They also meet the requirements of U.L. Std. 46, U.L. Std. 486 CSA Std. C22.2 No. 4 and CSA Std. C22.2 No. 6 being acceptable as grounding and bonding equipment suitable for direct burial. Thomas & Betts grid and ground rod connectors also satisfy the recommended practice for the selection of grounding connector joints described in IEEE 8 standard for qualifying permanent connections used in substation grounding. The connectors conform to the following IEEE Standard 8 requirements: 0 C current cycling reeze-thaw test Accelerated aging Nitric acid/salt spray. Mechanical, tensile and electromagnetic force (EM) criteria. Install in any weather cut downtime. Enhance safety. Easy to install no special training. Reliable installations through compression connections The Thomas & Betts method, utilizing compression tools with matching dies, forms the connector and conductor into a solid, homogeneous mass to provide an optimum electrical bond between connector and conductor. The dies are designed to produce a circumferential, hex-shaped compression rather than a simple indent. The circumferential compression creates a large area of high pressure contact between cable and connector which, in turn, assures high conductivity, low resistance, and high pullout values exceeding all industry requirements. Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 8

48 Grounding Grounding Connectors Blackburn Thomas & Betts offers its complete line of grid-ground compression connectors. Our EZ Ground connectors are designed for direct burial and offer a safe, efficient alternative to exothermic welding products. Grid ground installations do not require explosive charges, and can be installed in various climate conditions. These range taking products will reduce the number of connectors and dies needed for your installation. Thomas & Betts E-Z Ground products meet all applicable standards (IEEE8, UL46, CSA 22.2). Connectors are pre-filled with oxide inhibitors and sealed. C-Taps igure 6-6 Connectors 9 Grounding Plate 2 igure 8 6 GG Connectors 0 Pigtail Connectors Steel Grounding Stud TBG Series Lug I Beam Clamp 4 igure 6-8 Connectors 8 Splice/2-Way/Connector 2 igure 6 Connector Thomas & Betts Corporation. Specifications are subject to change without notice.

49 Grounding EZ Ground Compression Connectors Main H igure 6 Compression Ground Tap Connector Tap T MEETS IEEE 8 REQUIREMENTS Application Cable to Rebar Application Dimensions (In.) Dies for TBM 4M, 00A Cat. No. Main Tap A Ground Rod B Cable Range T H or TBMI 48 /0 STR kcmil #4 SOL. - #2 STR. # Rebar /8 #4 SOL. - #2 STR. f" n" G86R or /2" - /8" ROD thru /2 #4 Rebar 4860 /0 STR kcmil /0 STR. - 2/0 STR. # Rebar /8 /0 STR. - 2/0 STR. f" 2i" G86R or /2" - /8" ROD thru /2 #4 Rebar 486-CK /0 STR kcmil /0 STR kcmil # Rebar /8 /0 STR kcmil f" 2i" G86R or /2" - /8" ROD thru /2 #4 Rebar 48 #6 SOL. - #2 STR. #6 SOL. - #2 STR. f" 2l" 0A kcmil - 00 kcmil #4 SOL. - #2 STR. # Rebar /8 f" n" G26R or /8" - /4" ROD thru /4 #6 Rebar kcmil - 00 kcmil /0 STR. - 2/0 STR. # Rebar /8 /0 STR. - 2/0 STR. f" 2a" G26R or /8" - /4" ROD thru /4 #6 Rebar kcmil - 00 kcmil /0 STR kcmil # Rebar /8 /0 STR kcmil f" 2i" G26R or /8" - /4" ROD thru /4 #6 Rebar kcmil - 00 kcmil 0 kcmil - 00 kcmil # REBAR /8 0 kcmil - 00 kcmil c" 2k" G2R or /8" - /4" ROD thru /4 #6 Rebar * Tin plated version available of galvanized ground rods. Add suffix -TP Blackburn B igure 8 Compression Ground Rod Tap Connector A T H MEETS IEEE 8 REQUIREMENTS Dimensions (In.) Cat. No. A Ground Rod B Cable Range T H Dies for TBM4M 00A or TBMI GR2-202 d" 2 AWG-2/0 AWG g" n" G2R GR8-202 e" 2 AWG-2/0 AWG g" O" G2R GR4-202 f" 2 AWG-2/0 AWG g" 2i" G2R GR-202 " 2 AWG-2/0 AWG g" 2l" G2R GR d" /0 AWG-20 kcmil g" n" G2R GR e" /0 AWG-20 kcmil g" 2a" G2R GR f" /0 AWG-20 kcmil g" 2i" G2R GR-4020 " /0 AWG-20 kcmil g" 2k" G2R GR e" kcmil g" 2a" G2R GR f" kcmil g" 2k" G2R GR-0000 " kcmil g" 2W" G2R Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 8

50 Grounding EZ Ground Compression Connectors Element A L D g" L Element B f" MEETS IEEE 8 REQUIREMENTS Blackburn igure 6 to 8 Compression Ground Rod to Grid Connectors Dies for TBM4M, 00A Dimensions (In.) or TBMI Cat. No. A Ground Rod B Cable Range D L Element A Element B 48LR2* d" 2 AWG-20 kcmil j" 2d" G86R G2R 488LR2* d" 20 kcmil-00 kcmil j" 2d" G26R G2R 486LR8* e" 2 AWG-20 kcmil j" 2d" G86R G2R 489LR8* e" 20 kcmil-00 kcmil j" 2d" G26R G2R 48LR4* f" 2 AWG-20 kcmil d" 2e" G86R G2R 4900LR4* f" 20 kcmil-00 kcmil d" 2e" G26R G2R 490LR00 " 2 AWG-20 kcmil d" 2e" G86R G2R 4920LR00 " 20 kcmil-00 kcmil d" 2e" G26R G2R *Tin plated version available of galvanized ground rods. Add suffix -TP. L Element A D g" Element B igure 6 to 6 Compression Ground Grid Connectors L Die Selection for Element A Element B Element B to Element B to Dimensions (In.) TBM4M, 00A or TBMI Cat. No. Cable to Cable Ground Rod Rebar D T T-T A B 48L #6SOL-#2STR #6SOL-#2STR g" f" f" 0A 0A 486L #STR-20 kcmil #6SOL-#2STR d"-e" /8-/2" #-#4 Rebar g" f" f" G86R 0A 48L #2STR-20 kcmil #2STR-20 kcmil d"-e" /8-/2" #-#4 Rebar g" f" f" G86R G86R 488L 20 kcmil-00 kcmil #6SOL-#2STR e"-d" /8-/4" #-#6 Rebar g" f" f" G26R 0A 489L 20 kcmil-00 kcmil #2STR-20 kcmil e"-d" /8-/4" #-#6 Rebar g" f" f" G26R G86R 4900L 20 kcmil-00 kcmil 20 kcmil-00 kcmil e"-d" /8-/4" #-#6 Rebar g" a" a" G2R G2R Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E f" MEETS IEEE 8 REQUIREMENTS Thomas & Betts Corporation. Specifications are subject to change without notice.

51 Grounding EZ Ground Compression Connectors H C-Taps Cat. No. Main Tap H (in.) L (in,) Dies for TBM4M, 00A or TBMI * Crimps CTP22 #6 SOL. - #2 STR. #6 SOL. - #2 STR.**.6. HBKC CTP202 # STR. - 2/0 STR. #6 SOL. - #2 STR.**.4. 0A CTP2020 # STR. - 2/0 STR. # STR. - 2/0 STR..4. 0A CTP2020 /0 STR kcmil #6SOL. - 2/0 AWG**.9. G86R CTP2020 /0 STR kcmil /0 STR kcmil G86R CTP kcmil #6 SOL. - 2/0 AWG** G2R 2 CTP kcmil /0 STR kcmil G2R 2 CTP kcmil kcmil G2R Material: High Conductivity Copper. *Cat. No. 00 adapter required if using TBMI and XX series dies. **#6 AWG branch must be doubled. L MEETS IEEE 8 REQUIREMENTS Blackburn H Copper C-Crimps Wire Combinations Installing Die Dimensions (in.) Connector No. Run Tap Die Index TBM4M, 00A, TBMI L H BC48 6 SOL. - 4 STR. 8 SOL.-8 STR. BG OR e B8CR G I BC46-BB 6 SOL. - 4 STR. 6 SOL.-6 STR. BG OR e B8CR G f BC44 6 SOL. - 4 STR. 4 SOL.-4 STR. BG OR e B8CR G J BC24 2 SOL. - 2 STR. 8 SOL.-4 STR. C HBKC f BC22 2 SOL. - 2 STR. 2 SOL.-2 STR. C HBKC f Y BC202 /0 SOL. - 2/0 STR. 8 SOL.-2 STR. E or O HO n j BC2020-BB /0 SOL. - 2/0 STR. /0 STR.-2/0 STR. E or O HO n X BC402 /0 STR. - 4/0 STR. 6 SOL.-2 STR. or D HD h e BC4020 /0 STR. - 4/0 STR. /0 SOL.-2/0 STR. or D HD h e BC4040 /0 STR. - 4/0 STR. /0 SOL.-4/0 STR. or D HD h e Does not meet IEE8 Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 89

52 Grounding EZ Ground Compression Connectors Blackburn Pigtail Connectors When connecting cable to ground rod for direct burial or in concrete, the connector shall be wrought copper with min. conductivity of 99% I.A.C.S., such as Thomas & Betts series GR2-06. Hex compression with die code embossing shall be used. igure-8 connectors Hex compression intimately bonds cable directly to ground rod. Conforms to IEEE std. 8 U.L. 46 MEETS IEEE 8 REQUIREMENTS Cat. No. Cable Range Ground Rod Die Code for TBM4M, 00A or TBMI GR2-06 One Cable: /0 to 6 AWG d" 8H Two Cables: 2 to 6 AWG GR8-406 One Cable: 4/0 to 6 AWG e" 8H Two Cables: 2 to 6 AWG GR4-400 One Cable: 4/0 to /0 AWG f 99H Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E Thomas & Betts Corporation. Specifications are subject to change without notice.

53 Grounding EZ Ground Compression Connectors Structural Grounding Stud(s) TYPE TBGS These ground studs may be welded to steel structures with minimal construction welding equipment and connected to grounding conductors with the appropriate Thomas & Betts grounding connectors. The knurled portion of the stud will ensure excellent mechanical pull-out and electrical continuity for the integrity of the grounding circuit. Cat. No. Rod Size TBGS-4 b" TBGS-8 c" TBGS-8 e" TBGS-4 f" Specifications: These studs are made of high strength steel and coated with corrosion resistant copper cyanide. Intersecting medium knuring (2.0" long).2" Dia Intersecting medium knuring (2.0" long).60" Dia Blackburn Minimum flat contact surface WIDTH 0.80 LENGTH.2 Minimum flat contact surface WIDTH 0.0 LENGTH.2 TBGS-4 TBGS " Dia." Dia Intersecting medium knuring (2.0" long) Intersecting medium knuring (2.0" long) Minimum flat contact surface WIDTH LENGTH.2 TBGS-8 Minimum flat contact surface WIDTH 0.0 LENGTH.2 4 TBGS Thomas & Betts Corporation. Specifications are subject to change without notice. 9

54 Grounding EZ Ground Compression Connectors I Beam Ground Clamp I-beam ground clamp for connecting ground cable to I-beam, or any " max. structural steel member without welding or drilling. Breakaway bolt head shears at predetermined torque to assure tight connection. Heavy duty compression lug provides excellent current carrying capabilities. Surface of steel must be cleaned in accordance with the installation instruction sheet provided with the product. Connector Material: High conductivity cast copper bright dip. Clamp Material: Drop forged high grade steel, zinc plated. MEETS IEEE 8 REQUIREMENTS Blackburn TBMI Installing Tool, Cat. No. Wire Range Die Code IBG2-0 2 thru /0 AWG BG /0 thru 4/0 AWG 8 Hydraulic tooling with hex crimp dies. Satisfies requirements of NEC20-8 and 20-9 for connecting to the grounding electrode system. Material Cast Copper inish Electro-Tin Plated Cast Copper Two Way Connector Applications Heavy Duty Cable Die Cat. No. Size Die Code 04 8AWG AWG AWG AWG 4 08 AWG 4 09 /0AWG 4 0 2/0AWG 66 /0AWG /0AWG kcmil 6 0 kcmil kcmil kcmil 2 Use hydraulic tools with hex dies Thomas & Betts Corporation. Specifications are subject to change without notice.

55 Grounding EZ Ground Compression Connectors Ground Plates Cat. No. igure Cable Range H Dies GP kcmil e" G86R GP kcmil 4r" G26R GP kcmil e" G86R GP kcmil 4r" G26R MEETS IEEE 8 REQUIREMENTS 2 f A 2X d- UNC b f /4 4X d- UNC Blackburn c-6 UNC H Cable Range c-6 UNC H Cable Range igure igure Thomas & Betts Corporation. Specifications are subject to change without notice. 9

56 Grounding Cast Copper Connectors for Grounding Ground Clamp Ground Wire Rod Bolt Die Cat. No. Size Diameter (in.) Rebar # (in.) Size (in,) Code CC2C-4R #2-# AWG d or e 4 b -Brown CCC-4R # AWG d or e 4 b -Green CC0C-6R /0 AWG e or f 6 c 42-Pink CC20C-6R 2/0 AWG e or f 6 c 4-Black CC40C-6R 4/0 AWG e or f 6 c 4-Purple U.L. 46 Approved for direct burial. Blackburn Crimps to cable, clamps to ground rod and rebar. Provides a permanent, reliable connection. Uses standard Color-Keyed hand and hydraulic tools. Color-coded for easy installation die selection. Material: High conductivity wrought copper urnish with stainless steel hardware, 4" washers, bolts and nuts. Hex Die Die Wt. Inches Wire Bolt Code Unit Std. per Cat. Die Cat. No. Range Hole No.* Quan. Pkg. 00 No. Code No. L L2 D C H 0L /0-2/0 AWG c" *4 66 4p y s c 06L 4/0-20 kcmil c 8H **06 8H 4d 4p j c * TM4M, 00A, TBMI with hex crimp dies. **TBMI with hex crimp dies only. or terminating or connecting continuous runs of copper cable to flat surfaces, i.e., cable trays, structures, and busbar. The captivated Keeper Bar design extends the cable range, and helps hold cable prior to crimping, thereby facilitating installation. Saddles are marked with conductor size and die code. Conductor can be assembled to saddle with standard dies and hydraulic tools. Material: High conductivity cast copper G Bolt size D H C G2040R2 Series Connectors (for round posts) These connectors bond copper conductors to steel or aluminum fence post or top rail of round fence posts. They provide a quick, dependable installation at low installed cost, and use no incendiary materials. Material: U bolt steel Body cast copper alloy Grid to ence Grounding Clamps Steel & Alum. Ground Die Line Post Cat. No. Cable Range Code Range G2040R2 2/0-/0-4/0 6 2" G2040R2 2/0-/0-4/0 6 2d" G2040R 2/0-/0-4/0 6 " G20R2 2--/0 66 2" G20R2 2--/0 66 2d" G20 2--/0 66 " Install with hydraulic tooling with hex crimp dies. Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E Thomas & Betts Corporation. Specifications are subject to change without notice.

57 Grounding EZ Ground Compression Connectors NEW eatures and Benefits ast and easy installation Superior low-resistance, high-conductivity connections Uses conventional compression tools Produces a permanent connection with any combination of copper from #6 to #2 solid or stranded copper conductor, to a b" copper bus bar UL and CSA certified The unique patent pending design of Thomas & Betts new EZ-Ground Bus Bar Connector cuts your installation time in half, with results that are superior to conventional connectors. Installation can be completed in less than two minutes with one easy crimp! The connector attaches directly to the bus, saving the labor-intensive process of drilling and tapping. The unique jaw interface of the EZ- Ground Bus Bar Connector grips the copper bus, resulting in a low-resistance, high-conductivity connection. The EZ-Ground Bus Bar Connector can be used in OEM applications or Bus Bar Connector telecom applications cellular, PCS and others. It provides a continuous ground to the copper bus bar making it ideal for hut and tower applications. The design allows for installation in virtually any position horizontal or vertical, and it is suitable for inside and outside plant use. Installation can be completed using any T&B compression tool that accepts U-shaped die sets and is rated 2 ton or higher. Made from pure wrought copper and pre-filled with oxide inhibitor, the EZ-Ground Bus Bar Connector has proven performance and quality. Bus Bar Conductor Standard UPC Cat. No. (po) Range Ctn. Code GBBC22 b #2 AWG-#2AWG GBBC26 b #6 AWG-#2AWG Blackburn Use w/one WIRE #2 AWG.0 Use w/2nd WIRE #2 AWG Use this side of the connector when using only one wire..40 /4 Bus GBBC22 Use this side of the connector only when using two wires. Use w/one WIRE #2-#6 AWG.0 Use w/2nd WIRE #6 AWG.40 /4 Bus GBBC Thomas & Betts Corporation. Specifications are subject to change without notice. 9

58 Grounding EZ Ground Compression Connectors SnapTap Connector Blackburn Designed for bonding and grounding applications using copper, steel strand and ground rod, this unique connector can be easily installed using channel locks or pliers. It is a snap to assemble no special tools are required. Made from highstrength aluminum alloy with tin plating, the connector has excellent electrical and mechanical characteristics. An electrically superior pressure fit connection is achieved in seconds without expensive tooling. The connector is also easy to disassemble requiring only a flat-head screwdriver to release the connected body. The one-piece design keeps parts together minimizing loss of components prior to assembly. Simply separate the pieces and snap them in place for the installation. There is an audible snap indicating the connection is complete and that you have a proper installation. Tested according to UL46, these connectors exceed performance requirements. Packaging Connector Description Standard Inner Outer Order Cat. No. Main Branch Pack Pack Quantity JP62 No. 2 AWG Sol Copper No. 6 AWG Sol Copper JP66 No. 6 AWG Sol Copper No. 6 AWG Sol Copper JP46 b" Steel Strand No. 6 AWG Sol Copper JP66 j" Steel Strand No. 6 AWG Sol Copper JP86 c" Steel Strand No. 6 AWG Sol Copper JP26 d" Steel Strand No. 6 AWG Sol Copper JP26G d" Ground Rod No. 6 AWG Sol Copper JP264 b" Steel Strand Two-No. 6 AWG Sol Copper JP266 j" Steel Strand Two-No. 6 AWG Sol Copper JP268 c" Steel Strand Two-No. 6 AWG Sol Copper JP262G* d" Ground Rod Two-No. 6 AWG Sol Copper Note: All Tooless Connectors are UL listed. Only items with (*) are CSA listed. Bend back and forth to separate INSTALL SEPARATION POINT BODY PIECE IG. BODY PIECE General Usage Instructions Separate No special tools required. Use ordinary parallel jaw pliers to separate the connector into two parts. Hold one side of connector with pliers and bend opposite side back and forth until parts separate. (see fig. ) Caution: Be careful not to pinch fingers or thumb when separating parts. Keep fingers out of bend path when bending part against plier jaws. ends with a wire brush or emery cloth if necessary. 2. Place each conductor into the grooves in BODY piece. Press conductors with pliers to align and seat into grooves. (see fig. 2). Hold the conductors and BODY piece until it stops. Use parallel jaw pliers and grip the SNAP and BODY pieces as shown. (see fig. ). Apply pressure until connector snaps into place. Visually inspect snap to verify full insertion. The connection is now complete. (see fig. 4) Removal The connector can be disassembled using a flat-head screwdriver to pry the SNAP piece from BODY piece. IG. 2 Installation. Strip the insulation from each conductor. Be careful not to nick the conductor. Clean the conductor BODY PIECE SNAP PIECE IG. PIVOT GROOVE IG Thomas & Betts Corporation. Specifications are subject to change without notice.

59 Grounding EZ Ground Compression Connectors Cable to Cable or Rod High conductivity wrought copper, one piece construction for cable to cable, cable to rod, T and X connections. Suitable for direct burial or in concrete. One piece construction. Connects cable to cable and cable to rod, T and X connections. Suitable for direct burial or in concrete. Replaces exothermic welds. Conforms to IEEE standard 8. U.L. 46. Cable to Cable Range Rod to Cable Ground Cat. No. Main Die Code Branch Die Code Rod Die Code Cable Die Code GG2-2 #2 or # 4 #2 or # 4 GG0-0 /0 4 /0 4 GG /0 or /0 60 #2 4 GG /0 or /0 60 /0 4 GG /0 or /0 60 # 0 GG /0 or 20 #2 4 d" #2 or # 4 # 0 e" 80H #2 or # 0 GG /0 or 20 /0 4 d" /0 6 e" 80H GG /0 or 20 2/0 or /0 60 d" 2/0 or /0 60 e" 80H 2/0 or /0 60 GG /0 or 20 4/0 or 20 d" 4/0 or 20 e" 80H 4/0 or 20 GG kcmil 8 4/0 or 20 e" 80H 00 8 f" 8H 00 8 GG kcmil f" GG kcmil 8H 0 80H e" 8H 0 80H f" GG kcmil 8H 2/0 or /0 60 e" 8H 2/0 or /0 60 f" GG0-0 0 kcmil 80H 0 80H Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 9

60 Grounding EZ Ground Compression Connectors Type GRD Cable to Cable Connector Blackburn or Copper cable to cable ground grid connections Cast of high conductivity bronze alloy Suitable for direct burial Conductor Size Main Tap Installation Information max. min. max. min. Ground Hyd. No. Dimensions (in.) Cat. No. max. min. (mm 2 ) (mm 2 ) max. min. (mm 2 ) (mm 2 ) Rod Tool Die Crimps A B C GRD JB2HA B09CH 2 /2 /6 /6 GRD20 2/0 / /0 /0 6.4 JB2HA B0CH /6 /8 GRD / /0 /0 6.4 /8 JB2HA B2CH 2 /8 /6 /6 kcmil GRD / / /8 JB2HA B2CH 2 /8 /6 /6 kcmil kcmil Thomas & Betts Corporation. Specifications are subject to change without notice.

61 Grounding EZ Ground Compression Connectors L Nom. L2 Nom. Grounding Grid Connectors Heavy Duty Cast Copper Rod to Cable Installing Die Code Overall Rod to Cable Range Cable to Cable Range for TBM4M, 00A or TBMI Dimension (in.) Cat. No. Rod Size (in.) Cable Range Main Branch Rod Barrel Cable Barrel L L2 0 /0-2/0 AWG /0-2/0 AWG 66 g g 09 d-e 2- AWG 4/0-20 kcmil 2- AWG 8H 4H 4q 4l 060 d-e /0-2/0 AWG 4/0-20 kcmil /0-2/0 AWG 8H 8H 4k 4j 06 d-e 4/0-20 kcmil 4/0-20 kcmil 4/0-20 kcmil 8H 8H 4k 4j 069 f /0-2/0 AWG 00-0 kcmil /0-2/0 AWG 06H 66 4x 4x 0 f 4/0-20 kcmil 00-0 kcmil 4/0-20 kcmil 06H 06H b 4A 0 /0-2/0 AWG 00 kcmil /0-2/0 AWG 2H 66 4m 4g 0 4/0-20 kcmil 00 kcmil 4/0-20 kcmil 2H 8H 6l kcmil 00 kcmil 00 kcmil 2H 2H i i Cat. No. 00 adapter as required for all,00 Series dies, not for 600 Series. Ground rods 4/0-20 wire barrels suitable for d" smf e" rod 00 kcmil wire barrels suitable for " rods kcmil wire barrels suitable for e" rods Hydraulic tools only Does not meet IEE8 Blackburn or connecting perpendicular runs of stranded copper cable to ground rod. Material: Heavy duty cast copper Two Cables to Ground Rod TBMI TBMI Die for Die for Ground Cable Size Ground Cable Overall Dim. (in.) Rod Cat. No. Main Tap Rod Dia. Code L L2 Code 06-8GR 20 or 4/0 20 or 4/0 e" & d" 8H 4n b 8H 06-4GR 20 or 4/0 20 or 4/0 f 8H 4n f 06H Installs with Hydraulic Tools with hex crimp dies. Does not meet IEEE8 L Nom. L Nom. L2 Nom. Copperweld* Conductors & Rebar for Use with Cast Copper Connectors Cable Size Reinforcing Rod Size Copper Weld Conductor Size 2, AWG #8 or #6 /0, 2/0 AWG # c ( #8) or k ( #) 4/0, 20 kcmil #4 k (9 #9) or ( #) 00-0 # y (9 #8) or e ( #4) 00 kcmil #6 m (9 #6) * Reg. Trademark Copperweld Corporation U.L. Listed for use with cast copper connectors. Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 99

62 Grounding Cast Copper Connectors for Grounding Rise Cable lag Connector 600V Applications Material: High Conductivity Wrought Copper inish: Plain Riser cable flag connectors provide a low cost method of connecting directly to bus bar, eliminating an interface connection. All bolt holes are " on " centers. Riser cable flag connectors provides a low cost method of connecting directly to bus bar, eliminating an interface connection. All bolt holes are " on " centers. Material: High Conductivity Wrought Copper Blackburn T&B ig. Cable Color Die No. Of Material Dimensions (in.) Cat. No. No. Size Key Code Crimps THK. (in.) A B C #2-# GL2-0/24 PINK 42 p e 4 2j /24 /0 BLACK 4 GL0-20 2/0 AWG ORANGE 0 22/24 BLACK 4 p e 4 2j 2/24 BLACK 4 4/0-20 kcmil 2/24 GL /24 0/24 0 kcmil RED 2 q 4 b 4 b 2k GL0 60/24 N/A 80 2 q 4b 4d 2c /24 00 kcmil GL00 92/24 0 kcmil BROWN 94 2 q b 4g 2c 00/24 GL0,2 2 2/24 600/24 BLACK 06 4 q 8e 4f 2e NOTES:. TBMI only. 2. Both U barrels must be crimped to a single, continuous out length of conductor. It is not to be used as a splice. Installing tools: T&B Cat. No. TBMI, TBMBSCR, 00A, TBM4M, and TBM4BSCR hydraulic tools only. c" dia bolt holes on " centers A B A B C C Tooling: Pg. E8-E02 Die Selector Chart: Pg. E0-E igure igure Thomas & Betts Corporation. Specifications are subject to change without notice.

63 Grounding Ground Rod Clamps and Ground Rod Accessories Type JAB Ground Rod Clamps Dimensions (in.) Cat. No. A A Screw Socket Hex Nominal Wire Range (max.) (max.) Thread Set Head Rod Dia. max. min. Socket Hex Size Screw Bolt (in.) (mm) max. min. (mm 2 ) (mm 2 ) Screw Bolt UNC-2A B C D JABH Cast of high strength corrosion resistant copper alloy Both hex head and socket set screws available Long bearing surface of clamp on ground wire secures ground connection U.L. Listed for direct burial JAB2* JAB2H 2. 2 str. 0 sol JAB8 JAB8H.8 /0 str. 8 sol JAB4 JAB4H /0 str. 8 sol JAB4C /0 str. 8 sol to 9.0 JAB JABH 2.0 4/0 str. 8 sol * Not CSA listed Add suffix P to Cat. No. for tin plated clamp. Blackburn E D A dependable ground connection offered at a substantial saving Cast of high strength corrosion-resistant copper alloy Hex head bolts Simplified compact design will make a lasting, trouble-free connection U.L. Listed for direct burial Type G Budget Line Ground Clamps Dimensions (in.) Screw Nominal Wire Range A Thread Rod Dia. max. min. (max.) Size Cat. No. (in.) (mm.) max. min. (mm 2 ) (mm 2 ) Bolt UNC-2A B C D E G* 9. 4 str. 0 sol G str. 0 sol G.8 2 str. 0 sol G str. 0 sol * Not U.L. Listed RUS Listed Add suffix P to Cat. No. for tin plated clamp Thomas & Betts Corporation. Specifications are subject to change without notice. 0

64 Grounding Ground Rod Clamps and Ground Rod Accessories Blackburn Cast of high strength corrosion-resistant copper alloy; two types of screws available; type GG has a socket set screw; type GGH has a hex head bolt loating pressure bar distributes pressure evenly over a large area of the ground wire Axial groove keeps wire and rod in perfect alignment Types GG and GGH Heavy Duty Ground Rod Clamps Dimensions (in.) Cat. No.* A A Screw Socket Hex Nominal Wire Range (max.) (max.) Thread Set Head Rod Dia. max. min. Socket Hex Size Screw Bolt (in.) (mm) max. min. (mm 2 ) (mm 2 ) Screw Bolt UNC-2A B C GG2 GG2H 2. 2 str. 8 sol GG8 GG8H.8 2 str. 8 sol GG4H /0 str. 8 sol * Add suffix P to catalogue number for tin plated clamp. GG4H has no pressure bar or axial groove. Socket Size =.29 Width Across lats = Type GG Type GGH Type DGC Drive-On Ground Clamps Cat. No. Ground Rod Size Ground Wire Size DGC8-44 (..6) or 2 #4 sol. DGC8-66 (..6) or 2 #6 sol. DGC8-46 (..6) #4 sol. #6 sol. RUS Listed Drive-on design provides easy tool free installation, high reliability compression fit connection, and room for one or two ground leads High strength copper alloy provides increased tensile strength and long term corrosion resistance for direct burial applications U.L. 486A and U.L. 46 Listed RUS Listed Thomas & Betts Corporation. Specifications are subject to change without notice.

65 Grounding Ground Clamps Waterpipe Ground Clamps Ground Wire Water Pipe Cat. No. Size Size 2-TB #6, #4, #2 d", f", " or rebar 4-0 -TB #6, #4, #2 b", d" or 2" 4 #6, #4, #2 2d", " or d" -TB #6, #4, #2 4", 4d" or " 6 #6, #4, #2 6" Malleable iron. #6 #2 AWG ground wire. Blackburn Waterpipe Ground Clamps Ground Wire Water Pipe Cat. No. Size Size 902 #4-4/0 AWG d" " 90 #4-4/0 AWG b" 2" 904 #4-4/0 AWG 2d" d" 90-TB #4-4/0 AWG 4" " 906-TB #4-4/0 AWG 6" 90 #4-4/0 AWG 8" 908 #4-4/0 AWG 0" 909-TB #4-4/0 AWG 2" 902BU* #4-4/0 AWG d" to " 90BU* #4-4/0 AWG b" to 2" 904BU* #4-4/0 AWG 2d to d" 90BU* #4-4/0 AWG 4" to " 906BU* #4-4/0 AWG 6" 90BU* #4-4/0 AWG 8" 908BU* #4-4/0 AWG 0" 909BU* #4-4/0 AWG 2" *UL Listed for Direct Burial 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 0

66 Grounding Ground Clamps Blackburn High conductivity wrought copper construction. Compresses #8 AWG through 4/0 AWG cable and clamps onto pedestal posts up to " diameter square and 4" round. Can be used as an X or T configuration cable to post. Material: High Conductivity Copper Signal Reference Grid Connector Installing Tools and Die Codes TBM4M and TBMI Conductor Die Cat. Die Color Cat. No. Range No. Code Code SRG8-4 # Grey #6 to #4 28 Brown SRG2- #2 & # Pink SRG0-20 /0 & 2/0 0 0 Orange SRG0-40 /0 & 4/0 4 Purple Signal Reference Grid Clamp Wire Cat. No. Description Range 900 f" Square to " Round #8-#4 900BP (Bulk Pack) f" Square to " Round #8-#4 U.L. ile No. E-060 Approved for grounding and bonding per U.L. 46. Secures signal reference grid wire to raisedfloor support posts. Range-taking design: accepts #8 to #4 AWG grid wire; fits " round and 4" square trade size support posts. Lay-in feature means no kinks or bends. Quick, easy installation. Only one screw to tighten. Allows grid wire to make direct, low resistance contact with support posts. Material: Stamped steel, zinc plating Thomas & Betts Corporation. Specifications are subject to change without notice.

67 Grounding Ground Clamps U.L. 46 Listed for direct burial. or connecting copper or copper clad steel grounding conductor to ground rod or pipe. Excellent for connecting multiple electrodes with a single cable as in substation grounding. All components are cast or forged from copper alloy. Specially designed spacer provides proper alignment between cable and electrode and affords more positive contact area. U-Bolt Ground Clamps Conductor Nominal Rod IPS Pipe Dimensions Range (cu) Size (in.) Size (in.) (in.) Cat. No. max. min. max. min. max. min. A B C GUV f" e" c" 2m l 2b GUV82 2/0 4 f" e" c" 2m l 2b GUV /0 f" e" c" 2m l 2b GUV " g" f" d" 2f l 2e GUV82 2/0 4 " g" f" d" 2f l 2e GUV /0 " g" f" d" 2f l 2e GUV b" a" " j l 2f GUV82 2/0 4 b" a" " j l 2f GUV d" c" b" k 9l 2n GUV82 2/0 4 d" c" b" k l 2n GUV /0 d" c" b" k l 2n GUV g" e" d" n 9l i GUV82 2/0 4 g" e" d" n l i GUV /0 g" e" d" n l i GUV c" 2" 2" 4k l L GUV202 2/0 4 2c" 2" 2" 4k l L GUV /0 2c" 2" 2" 4k l L GUV222 2/0 4 2g" 2d" 2d" 4n l 4i GUV /0 2g" 2d" 2d" 4n 9l 4i GUV02 2/0 4 d" " " l l 4m GUV /0 d" " " l l 4m GUV22 2/0 4 4" d" d" 6h l d GUV402 2/0 4 4d" 4" 4" 6j l L GUV /0 4d 4" 4" 6j l L * or tin plating add suffix P to Cat. No. Contact factory for price and availability. U.L. does not list tin plated bronze grounding devices. Blackburn A B C Ground Electrode Boxes Wt/ 00 Standard Cat. No. Description lb. kgs. package 628 Pregalvanized steel Hot dip galvanized gauge steel. 0 inches diameter, 2 inches depth Thomas & Betts Corporation. Specifications are subject to change without notice. 0

68 Grounding Ground Rod Clamps and Ground Rod Accessories Type C Sectional Ground Rod Couplings Size Thread Cat. No. (Nominal Diameter) Size 0C " " UNS 0LC* " L 9 6" 2 UNS 60C* " " UNS 0C* 4" 4" 0 UNS 80C* " " 8 UNS *U.L. Listed 46 (42H). CSA lists rods " and larger, 0 and longer. Blackburn Threaded couplings are of high strength, corrosion-resistant alloy; streamlined design reducesdriving friction; couplings are tapped so that they may be used on all standard threaded sectional rods RUS Listed. Type DS Driving Studs Size Thread Cat. No. (Nominal Diameter) Size 0DS " " UNS 0LDS* " L 9 6" 2 UNS 60DS* " " UNS 0DS* 4" 4" 0 UNS 80DS* " " 8 UNS Driving Studs of high strength steel may be used with all standard threaded couplings *U.L. Listed 46 (42H). CSA lists rods " and larger, 0 and longer. REA Listed. Threadless Coupling or joining non-threaded, sectional, copper bonded, steel ground rods Coupling is manufactured of a high strength, corrosion resistant, copper alloy Threadless Couplings and Driving Cap Dimensions (in.) Cat. No. Description Length Diameter 0LCNT* " L Threadless Coupling CNT2* " Threadless Coupling CNT* 4" Threadless Coupling DSNT " Threadless Driving Cap *U.L. Listed. See the new ground rod driver in the Installation Tools section, pg. E00. Threadless Driving Cap Prevents mushrooming of ground rod while driving to insure proper fit of coupling Driving cap is manufactured of high strength, hardened steel Thomas & Betts Corporation. Specifications are subject to change without notice.

69 Grounding Ground Plates Galvanized Ground Plates Cat. No. Description Conductor Range 06TB Galvanized ground plates 8 sol. to /0 str. 06BTB Galvanized ground plates with JAB8H connector 8 sol. to /0 str. RUS Listed. 4" thick, hot-dipped galvanized Can be as efficient as two ground rods (2-0' x ") Must be buried at least 600mm (24") below finish grade level according to CEC Rule 0-02 More efficient than butt wrapping poles Made of electrolytic sheet copper Built-in high pressure connector for ground lead, or supplied with #6 AWG copper pigtail pre-attached Plates are grooved for trapping moisture Type GP Copper Pole Bottom Ground Plates for Multigrounded Neutral Construction Pigtail Wire Range min. max. Diameter of Plate Cat. No. min. max. (mm 2 ) (mm 2 ) (in.) (mm) GP00 d 9 GP0 8 2 sol GP4 4 6 GP00 GP008 GP08 #6 AWG solid CU Pigtail with 8" conductor #6 AWG solid CU Pigtail with 8" conductor #6 AWG solid CU Pigtail with 8" conductor d 9 d Blackburn Type PB Copper Pole Ground Plates Wire Range Surface Area Cat. No. max. min. inished Size sq. in. PBGW 2/0 str. 0 sol. x 6 PBH 4 str. 4 sol. x 6 RUS Listed. Installed on butt end of utility poles to provide an economical, low resistance neutral ground. Installed cost considerably less than buttwrapped poles. Plate portion fabricated of.02 pure copper. PBGW connector is eye-bolt type, cast of corrosion resistant aluminum bronze alloy, with silicon bronze nut and lock washer. Riveted all copper terminal lug is an integral part of the PBH, and provides the means of connection to the grounding conductor Thomas & Betts Corporation. Specifications are subject to change without notice. 0

70 Grounding Mechanical Grounding Connectors Type GTC Tower Ground Clamps Conductor Range max. min. Channel Dimension (in.) Cat. No. max. min. (mm 2 ) (mm 2 ) Thickness A B D E G H R GTC 2/0 str. 4 sol Blackburn Bolt has square shank to prevent turning and allow clamp to be tightened with one wrench GTC 2 and 24 are two-piece clamps for connecting ground lead cable to flat metal surface; ideal for grounding substations on tower footings Castings are of high strength, corrosion resistant copper alloy GTC and 4 are economical one-piece clamps which perform the same function as two-piece clamps except the under pad support is omitted and conductor is connected directly to tower Add suffix L to Cat. No. for " channel thickness GTC4 20 kcmil 2/0 str GTC2 2/0 str. 4 sol GTC24 20 kcmil 2/0 str Type GTC and 4 Type GTC 2 and 24 6 c nut Split Washer lat Washer c Bolt with Ribbed neck and Phillips recessed head CTG20 Wide Range Tower Ground Clamp Wide Range Cat. No. (2 sides) Height Width Depth Nut (lats) #2 sol. (.28 Dia.) CTG20 20 kcmil (. Dia.) Tin plate body Galvanized hardware or use with aluminum or copper conductors. In aluminum or galvanized steel cable tray. Ribbed neck on the bolt prevents rotation during tightening if.440 dia. hole is used NEW Lay-in Lug Connector These grounding connectors are manufactured with high strength 606-T6 aliminum alloy to insure both maximum strength and conductivity. Dual rated for both copper and aluminum conductor. The open-faced design allows the installer to quickly lay-in the grounding conductor as a jumper to multiple conduits with no break in the ground conductor. igure Cond. Range Stud Dimensions AWG Size H W L Cat. No. ig. No. in. (mm 2 ) in. (mm) in. (mm) in. (mm) in. (mm) LL LL04 / LL06 2 / LL C Rating (486B Listed) igure Thomas & Betts Corporation. Specifications are subject to change without notice.

71 Grounding Mechanical Grounding Connectors Bronze Jumper Clamps Max. Min. Max. Min. Plated Plated Unplated Unplated Cat. No. Groove Groove Groove Groove K /0 ACSR 2 SCG 6 ACSR 2 SCG 2/0 str. copper 8 solid copper amerductor amerductor 6 Copperweld* 9 D 6 galv. strand 8 solid iron 2A Copperweld* Copperweld* etc. or all combinations of aluminum, copper and Steel conductors Cast of high strength bronze alloy urnished with silicon bronze bolt and lockwasher lockwasher minimized loosening of installed clamp Parallel groove design; no need to remove bolt for installation Only one size for all requirements from No. 8 solid copper to /0 ACSR or 2/0 copper Service Post Connectors * Trademark of Copperweld Steel Co. Plated with plating removed from one groove. or use with alumum, amerductor, or galvanized steel strand to copper or copper bonded steel wires. Q a s Blackburn Application The Blackburn line of Service Post Connectors are designed for applications including steel structure, fence post or transformer grounding involving one or two cables. Service Posts can also be used to tap one or two cables from bus bar. Construction & Ratings Bolts used in the Service Post are machined from high conductivity bronze alloy while the nuts are coldformed from high strengh, corrosion resistant copper alloy. Pressure bars are copper through 4/0 size, while copper alloy is used for 0 kcmil size and above. Bolts and nuts are of the traditional Blackburn hex design for easy installation. Service Post Connectors are available in sizes accommodating AWG copper conductor ranges of #2 _ 00 kcmil stranded (4 mm2-240 mm2) and #2- #2 solid (4 mm2 - mm2). Both short and long stud versions are available. The line includes single conductor and double conductor connectors. or copper to copper connections or grounding of steel structures, fence posts or transformers using one or two cables or tapping one or two cables from bus bar Hex design bolts are machined from high conductivity bronze alloy Nuts and pressure bars are cold-formed from high-strength copper or copper alloy UL 486A and UL 46 Listed Type DS Service Post Connectors, Short Stud Cat. No. Conductors AWG mm 2 Maximum Double Single Stranded Solid Diameter Conductor Conductor max. min. max. min. Range (in.) Stud Size SP0DS SP0SS mm 2 4mm 2 0mm 2 4mm x SPDS SPSS mm 2 6mm 2 0mm 2 6mm x SP2DS SP2SS mm 2 6mm 2 6mm 2 6mm x SPDS SPSS mm 2 6mm 2 mm 2 6mm x SP4DS SP4SS mm 2 6mm 2 mm 2 0mm x SPDS SPSS / mm 2 mm 2 mm x 4 SP6DS SP6SS 2/ mm 2 mm 2 mm x 4 SP8DS SP8SS 4/0 9mm 2 mm x SP9DS SP9SS 0 /0 0mm 2 0mm 2.. x SP0DS SP0SS 00 /0 240mm 2 9mm x Thomas & Betts Corporation. Specifications are subject to change without notice. 09

72 Grounding Mechanical Grounding Connectors Blackburn or copper to copper connections or grounding of steel structures, fence posts, transformers using one or two cables or tapping one or two cables from bus bar Hex design bolts are machined from high conductivity bronze alloy Nuts and pressure bars are cold-formed from high-strength copper or copper alloy U.L. 486A and U.L. 46 Listed Pressure bars are copper through 4/0 size; copper alloy is used for 0 kcmil size and above Available in sizes accommodating AWG copper conductor ranges of #2 00 kcmil stranded (4mm 2 240mm 2 ) and #2 #2 solid (4mm 2 mm 2 ) Line includes single conductor and double conductor connectors Type SP Service Post Connectors, Long Stud Cat. No. Conductors AWG mm 2 Maximum Double Single Stranded Solid Diameter Conductor Conductor max. min. max. min. Range (in.) Stud Size SP0DL SPDL SP2DL SPDL SP4DL SPDL SP6DL SP8DL SP9DL SP0SL SPSL SP2SL SPSL SP4SL SPSL SP6SL SP8SL SP9SL SP0DL SP0SL mm 2 4mm 2 0mm 2 4mm mm 2 6mm 2 0mm 2 6mm mm 2 6mm 2 6mm 2 6mm mm 2 6mm 2 mm 2 6mm mm 2 6mm 2 mm 2 0mm 2 / mm 2 mm 2 mm 2 2/ mm 2 mm 2 mm 2 4/0 9mm 2 mm 2 0 /0 0mm 2 0mm 2 00 /0 240mm 2 9mm x x x x x.8.29 x x x.. x x 4 Transformer Grounding Connectors are cast of high conductivity bronze; " stud fits all standard EEI-NEMA distribution transformers Eye bolt on TTC2 rotates to accommodate cable in either vertical or horizontal direction One size connector to handle full range of grounding conductors from #8 through 2/0 str. No special tools required Type TTC Transformer Tank Ground Connectors Conductor Range Stud Thread max. min. Size Dimensions (in.) Cat. No. max. min. (mm 2 ) (mm 2 ) UNC-2A A B C TTC2 2/0 str. 8 sol TTC str. 0 sol TTC4 str. 0 sol TTC2P 2/0 str. 8 sol TTCP* str. 0 sol TTC4P* str. 0 sol RUS Listed. * Tin Plated. TTC2 TTC4 TTC Thomas & Betts Corporation. Specifications are subject to change without notice.

73 Grounding Mechanical Grounding Connectors Aluminum Water Pipe Clamp Water Conductor Dimensions Steel Aluminum Pipe Range (in.) Clamp Wire Cat. No. Size max. min. A B C Screw Screw AJ - /0 str. #4 sol slot AJ kcmil # socket AJ kcmil # socket U.L. listed for both copper and aluminum conductors to steel pipe and copper water tubing or connecting grounding conductor to either steel or copper pipe, rod or tubing Tin plated for corrosion resistance or use with copper or aluminum conductor Type AJ Type AJ2 Blackburn Budget Price Cast Bronze Clamp Water Conductor Dimensions Pipe Range (in.) Cat. No. Size max. min. A B C JJR to #4 str. #0 sol. 2 Add suffix C to Cat. No. to specify plating. 2 Similar to above but lighter in construction Die Cast Clamps Conductor Water Pipe Range Cat. No. Size max. min. BJ- - #2 str. #0 sol. BJA* - #6 AWG #8 AWG * Not U.L. Listed Budget price clamps Made of die cast zinc alloy with zinc plated screws Model BJA for use with armored cable 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

74 Grounding Mechanical Grounding Connectors Cast Bronze Clamps Water Conductor Dimensions Pipe Range (in.) Cat. No. Size max. min. A B C D E G JA to #6 sol. #0 sol JA-2 4 to 2 #6 sol. #0 sol JA to 4 #6 sol. #0 sol Add suffix C to Cat. No. to specify plating. Blackburn or connecting armored cable to water pipe Clamping portion similar to standard J clamp Special pressure bar grips armor or outer cable insulation to lessen chances of grounding conductor being pulled out Zinc plated screws Cast Bronze Clamps for Conduit Water Conductor Dimensions Conduit Pipe Range (in.) Cat. No. Size Size max. min. A B C D E G or grounding rigid conduit systems Continuity from rigid conduit system to ground provided by cast bronze threaded conduit hub Hub swings 60 for easy alignment Heavy brass washer provides protection for clamped grounding conductor Zinc plated screws Cast bronze pipe clamping portion identical to that used in JA clamp JP-2 to #6 sol. #0 sol JP-22 4 to 2 #6 sol. #0 sol JP to 4 #6 sol. #0 sol JP-4 4 to #2/0 str. #0 sol JP to 2 #2/0 str. #0 sol JP to 4 #2/0 str. #0 sol JP- to #/0 str. #0 sol JP-2 4 to 2 #/0 str. #0 sol JP to 4 #/0 str. #0 sol Add suffix C to Cat. No. to specify plating Thomas & Betts Corporation. Specifications are subject to change without notice.

75 Grounding Mechanical Grounding Connectors Cast Bronze Clamps with Copper Strap Water Conductor Conduit Pipe Range Cat. No. Size Size max. min. JPS-2-6 sol. 0 sol. JPS-4 4-2/0 str. 0 sol. JPS- - /0 str. 0 sol. Add suffix C to Cat. No. to specify plating. or grounding rigid conduit systems Same features as JP clamp plus ease of alignment afforded by flexible copper strap Strap helps protect conduit system from water system vibrations Zinc plated screws U.L. 46 Listed for direct burial High strength, high conductivity copper alloy (over 80% copper) To connect copper ground wire to water pipe, copper tubing, or ground rods Cast Bronze Ground Clamps Water Pipe Conductor Cat. No. Size Range JD - #2 str.-#0 str. J2D 4-2 #2 str.-#0 str. Blackburn Type J Cast Bronze Ground Clamps Water Pipe Conductor Range Dimensions (in.) Cat. No. Size max. min. A (max.) B C or connecting grounding conductor to water pipe or copper tube Cast of high strength, highly conductive copper alloy Screws plated for corrosion resistance UL listed J to 2 str. 0 sol J2BB 4 to 2 2 str. 0 sol. 4 6 J224 2 to 4 4 str. 0 sol J6 4 4 to 6 4 str. 0 sol Thomas & Betts Corporation. Specifications are subject to change without notice.

76 Grounding Mechanical Grounding Connectors Type JPT Cast Bronze Clamps for Conduit Water Conductor Range Cat. No. Conduit Size Pipe Size max. min. JPT " to " JPT2 " or 4" EMT 6 sol. 0 sol. " Rigid 4" to 2" JPT4 2 " to 4" Blackburn Pipe clamping portion identical to JA clamp Pressure bar type conduit hub adjusts to fit " or 4" EMT or " rigid conduit Hub swings 60 for ease of alignment Brass washer provides positive contact with grounding conductor Zinc plated screws Conduit Hubs Ground Wire Conduit Cat. No. Size AWG Size 90 #8 to #2 /2" Conduit 940 #8 to #2 /4" Conduit 90 #8 to #/0 " Conduit 9 #8 to #4/0 /4" Conduit 960 #8 to #4 Armored Wire Material: Malleable iron Rugged cast bronze threaded hub Provides positive connection between rigid conduit and water system in conjunction with J clamp Type CH Bronze Conduit Hubs Conduit Size Conductor Range Cat. No. (in.) max. min. CH2 /2 6 sol. 0 sol. CH4 /4 2/0 str. 0 sol. CH /0 str. 0 sol Thomas & Betts Corporation. Specifications are subject to change without notice.

77 Grounding Grounding Conduit Hubs Blackburn Budget Line Ground Clamps Dimensions (in.) Nominal Wire Range A Thread Cat. Rod Dia. max. min. (max.) Size No. (in.) (mm) max. min. (mm 2 ) (mm 2 ) Bolt UNC-2A B C D G* 9. 4 str 0 sol G str 0 sol Type G A dependable ground connection offered at a substantial saving; cast of high strength corrosion-resistant copper alloy. Hex head bolts. Simplified compact design will make a lasting, trouble-free connection. G#.8 2 str 0 sol G str 0 sol.6.2-6> 6 * Not U.L. Listed # REA ListedAdd Add suffix P to Cat. No. for tin plated clamp. Request pricing Ground Clamp Water Pipe, Copper Cat. Tubing Grd. No. Material Size Rod Size 826 M.I. ", 4" "-" 846 Bronze ", 4" "-" 849 Brass "-" O.D. 840* M.I. ", 4" or " Blackburn or armored and unarmored wire or unarmored copper wire #6, #4. or copper and aluminum conductors; for 4 thru 2 cu. unarmored copper wire corrosive and outdoor use. U.L. approved for direct burial. * #8 thru #4 AWG. Not CSA Certified Ground Clamps for K&L Grade Copper Tubing Only Ground Water Pipe Cat. Wire & Ground Rod No. Range Size/Desc. 844* #8-#4 "-" 888 #8-#4 "-" also rebar 4-0 * With Steel Screws ** With Bronze Screws, Not CSA Certified or U.L. U.L. approved for direct burial. Silicon Bronze Screws. Swivel cable tray clamps for aluminum and steel trays with regular or reinforced flanges. Serrations and biting teeth on clamping saddle provides a high quality bond between conduit and clamp. " to 6" sizes that can be clamped to any position in a 90 arc. Hardened steel screws bite into tray and provide positive bond. Malleable iron hub and steel u-bolt accepts conduit from any angle. Swivel Tray Clamp Cat. Conduit No. Size 6209 "- 4" 62 "- 4" 624 "-2" "-" 628 "-4" 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

78 Grounding lexible Braid lexible Braids Type B lexible Braids Dimensions Blackburn * Certified C22.2 No. 4 Grounding & Bonding Equipment. Listed UL46 and UL486A Grounding & Bonding Equipment. No. of C D E Circular Bolt Braids in errule Distance Cat. No. Mils Hole errule Thickness Width Length Ctr. to Ctr. BB2-* b N/A BC2-* k N/A BD2-* 6800 k N/A BD2* 6800 k B2D2-* 600 k N/A B2D2* 600 k BD2-* k N/A BD2* k BXD2-* 0600 l N/A BXD2* 0600 l B2XD2-* 2200 l N/A B2XD l BXD2-* 6800 l N/A BXD2* 6800 l BE2-* l N/A BE2* l B2E2-* 6000 l N/A B2E2* 6000 l BE l B4E l B l B l B l B l BG l B2G l BG l B4G l Catalog number shown in 2" lengths. Standard lengths offered in 6, 2, 8, 24, 0, and 6 inches (end to end). Change the 2 in the above catalog numbers to the desired length. (-) indicates bolt hole per ferrule. See amperage tables on page as a reference for grounding and bonding, or continuous current applications. B4 series is not listed/certified. or custom flexible braids, contact Customer Service. C D E Tin-plated copper braids and ferrules for high conductivity and corrosion resistance. lexible copper braids for use in substation and grounding applications. lexible braids allow for linear expansion, equipment vibration, and offset connections. lexible Braid in a Roll 0 foot minimum Cat. No. Circular Mils. Thickness (in.) Width (in.) BBRL BCRL BDRL BXDRL errules or lugs not included Thomas & Betts Corporation. Specifications are subject to change without notice.

79 Grounding lexible Braid Selection Guide Minimum Size lexible Braid for Continuous Current Applications Circular Amperage Circular Amperage Cat. No. Mils Capacity Cat. No. Mils Capacity BB BC BD BD B2D B2D BD B BXD BXD B2XD B2XD BXD BXD Grounding and Bonding Applications Minimum Size Conductors for Bonding Raceways and Equipment Rating or Setting of Overcurrent Device in Circuit Ahead of Equipment, Conduit, Etc. Copper Wire Not Exceeding Amperes Circular Mils (6 AWG) (4 AWG) ( AWG) (2 AWG) ( AWG) (/0) (2/0) (/0) (4/0) Based on table 6 C.E.C. BE BE B2E B2E BE B4E B B B B BG B2G BG B4G Minimum Size of Bare Copper Grounding Conductor Maximum Maximum ault Duration Available with Exothermic Weld, Short Circuit Compression or Bolted Joint Current 0. Seconds.0 Second Amperes Circular Mils Circular Mils Based on table C.E.C. Size calculated in accordance with IEEE No. 80. Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

80 Grounding Grounding Accessories Metallic Gradient Control Mat Wt/00 Standard Cat. No. Description lb kg package 6466 Mat with connectors Mat without connectors ft. x 6 ft. hot dip galvanized mat is made from 6"x6" welded mesh, /4" diameter. Silicone bronze connector, bolt, nut and lockwasher. To reduce risk and prevent build up of dangerous potential differences between high voltage equipment or structures and the user standing on the ground surface. CEC Rule 6-08 Blackburn Type J lexible Ground Clamp Copper Ground Wire Size Pipe Size (in.) Copper Tube Size (in.) Cat. No. max. min. max. min. max. min. J 2 8 /4 /8 /4 /2 Type J or connecting to steel pipe or copper water tube Accommodates ", ", 4", ", 4", pipe sizes and ", 4",, 4", copper water tube sizes Accommodates copper ground wire #8 through #2 Specially designed T bolt 22 gauge soft copper strap with unique locking slots Hex head nuts may be tightened with standard wrench or special telephone company hex head driver Thomas & Betts Corporation. Specifications are subject to change without notice.

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2

More information

GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER

GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER ALUMINUM GA9000 Recommended for aluminum or aluminum to copper distribution, service or tap connections. Add Suffix

More information

General Terms and Conditions

General Terms and Conditions General Terms and Conditions MINIMUM ORDER CARGE PER ITEM $200.00 PRICES All prices are subject to change without notice and orders will be billed at prices in effect at the time of shipment. TRANSPORTATION

More information

TABLE OF CONTENTS. Type HFB-P1... A-22. Type HFB-N... A-23. Types KA-U, KKA-U... A-24. Type K2A-U... A-25. Types K3A-U, KK3A-U...

TABLE OF CONTENTS. Type HFB-P1... A-22. Type HFB-N... A-23. Types KA-U, KKA-U... A-24. Type K2A-U... A-25. Types K3A-U, KK3A-U... BURNDY Mechanical A-1 TABLE OF CONTENTS Types KS, KS-3 & SC... A-4 Type KSU............ A-5 Type KSA............ A-6 Types KVS, KVSU...... A-7 Types KVSW, KVS-A... A-8 Type QPX............ A-9 Type QPX-Y.........

More information

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS B-2 Performance The terminals and splices in this catalog are approved, per MIL-T-7928 and/or UL 486, where indicated. Table 1 shows the performance requirements for terminals used in military and commercial

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products. H W U J B L T Substation Bolted TABLE OF CONTENTS COPPER SUBSTATION Introduction............... L-3 Type HFBW Bar Clamp............... L-13 Type NT Tube to Tube.............. L-4 Type HFB-P1 Bar Clamp...............

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS GUY-GRIP Dead-end NOMENCLATURE Please visit our web site at www.preformed.com for additional literature.guy-grip Dead-end Application Procedure - SP2045 Cross-over Marks: (A) Indicate starting point for

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

Meter Connection Products: Overview

Meter Connection Products: Overview : Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature

More information

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers Design Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the American Standard Code for Pressure Piping. Hanger Design Pipe hangers are of advanced design

More information

Grounding Systems. Table of Contents. EZGround

Grounding Systems. Table of Contents. EZGround EZGround Grounding Systems Table of Contents Thomas & etts offers a complete range of grounding products including mechanical, compression and exothermic systems. Whatever the application, there is a Thomas

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS 4. GENERAL SECONDARIES & SERVICES 4.- INDIVIDUAL PHASE SECONDARY OVERHEAD LINE EXTENSIONS 4.- SECONDARY AND SERVICE CABLE SPLICES 4.- INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 4.- 4. POLE ATTACHMENTS

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE The Contractors Choice the Contractors Choice Founded in 1958, with locations in Tulsa and Broken Arrow, Oklahoma. is part of the Quality Brands of Continental Industries. TABLE OF CONTENTS THE PROCESS...4

More information

Welcome to Douglas County PUD

Welcome to Douglas County PUD Welcome to Douglas County PUD We are committed to providing the best possible utility services at the lowest possible cost consistent with sound business principles. To better serve you, please fill out

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. This section governs the products and execution requirements relating to furnishing and installing grounding and

More information

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application Introduction Designed for Indoor and outdoor applications Non-tension tap and splice applications Used

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated

More information

Series 2000PV Mechanical Joint Restraint for PVC Pipe

Series 2000PV Mechanical Joint Restraint for PVC Pipe Series 2000PV Mechanical Joint Restraint for PVC Pipe Features and Applications: For restraining plain end PVC pipe at mechanical joint fittings and appurtenances Sizes 3 inch through 36 inch Sizes 42

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

Material and Process. Specification

Material and Process. Specification s 146-67- 1 of 7 Document By: Title Name 1. Purpose 1.1 This document defines approved revision levels of Material and Process specifications used by Onboard Systems. This list is for supplier reference

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

hors Anc Eaton's B-Line series fasteners 183

hors Anc Eaton's B-Line series fasteners 183 183 Glossary Prefix - Description Screw Dia. Length Suffix ACB - Concrete Anchor Bolt 4 - #4 75-3 /4" AN - Acorn Nut ACPD - Bang-IT 6 - #6 81-13 /16" CH - Combo Head ACPW - Wood-Knocker 8 - #8 87-7 /8"

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed

More information

Suffix for Disc Material Size A B C I.D. O.D. B.C. Holes Black White

Suffix for Disc Material Size A B C I.D. O.D. B.C. Holes Black White Wet-R-Dri Valve A TA STYLE LIGHTWEIGHT COMPACT VERSATILE B I.D. Size Standard Model Detent Model Standard Material Max. Working Body Disc Pressure WD00 AL B. WD0 AL B. Aluminum WD00 GI B. WD0 GI B. Grey

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

Thermocouples and Accessories Product Catalog

Thermocouples and Accessories Product Catalog Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry

More information

PTFE Pipe Slide Assemblies

PTFE Pipe Slide Assemblies PTFE Slide Assemblies Overview Application Anvil PTFE pipe slide assemblies are designed to support the pipe and provide for lateral and axial movement due to thermal expansion and contraction of the piping

More information

TABLE OF CONTENTS BURNDY. Overhead Distribution TAP CONNECTORS H-3 - H-20 H-21 - H-40 H-41 - H-43

TABLE OF CONTENTS BURNDY. Overhead Distribution TAP CONNECTORS H-3 - H-20 H-21 - H-40 H-41 - H-43 BURNDY Overhead Distribution TABLE OF CONTENTS TAP CONNECTORS Mechanical (Bolted) Compression Transformer and Equipment H-3 - H-20 H-21 - H-40 H-41 - H-43 COMPRESSION SPLICES Service Entrance Neutral Jumper

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

Large cable sizes stronger than pipe/strut

Large cable sizes stronger than pipe/strut Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant

More information

Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available

More information

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Page no. :1 of 11 SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Prepared by: Eng. T. Lev (-חתום-) Checked by: I. Bester (-חתום (- Approved by: Eng. Y. Samoocha (-חתום (- 1 Page no.

More information

SECTION TAPPING SLEEVES AND VALVES

SECTION TAPPING SLEEVES AND VALVES SECTION 33 12 16.17 TAPPING SLEEVES AND VALVES PART 1: GENERAL 1.01 SCOPE Furnish, install and test all tapping sleeves, tapping valves, and tapping saddles as shown on the Drawings. 1.02 RELATED WORK

More information

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves UL / FM TAPPING VALVE SECTION Rev. 2-15 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D.

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD HOLE SAMPLING & MONITORING MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com HOLE SAMPLING & MONITORING TABLE OF CONTENTS HOLE SAMPLING & MONITORING OVERVIEW...2 SPLIT

More information

CLASS I & II HEAVY DUTY EQUIPMENT CATALOG

CLASS I & II HEAVY DUTY EQUIPMENT CATALOG CLASS I & II HEAVY DUTY EQUIPMENT CATALOG 901 Sibley Highway Saint Paul, MN 55118-1792 651-455-7661 1-800-777-1230 GENERAL INFORMATION INTRODUCTION: THOMPSON LIGHTNING PROTECTION, INC. CAME INTO BEING

More information

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

CHEMICAL /4 3/8 to 5/8 /8 3/4 to 1-1/4 1 10 194 ASTM A193 GRADE B7 HIGH-STRENGTH CARBON, ZINC PLATED (ASTM B 633 YELLOW DICHROMATE) B7 (AISI 414) anchor rod is supplied with nuts meeting the requirements of ASTM Specification A 194, Grade 2H (ASTM

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing CPO 2:1 Shrink Ratio Thin-Wall Tubing, Non-Lined Flame-retardant, cross-linked polyolefin Continuous operating temperature: -55 C to 135 C Shrink temperature of 120 C Meets UL and CSA standards; MIL-DTL-23053/5

More information

FLEXTRAY Wire Basket - Splicing Accessories

FLEXTRAY Wire Basket - Splicing Accessories D-7 B-Line series Cable Tray Systems Washer is staked to bolt, holding part stationary during installation Fewer parts to handle For use with all tray widths and sizes Finishes : EG, BLE BLE suffix indicates

More information

SECTION SLUICE GATES

SECTION SLUICE GATES SECTION 11100 SLUICE GATES PART 1--GENERAL Fill in the blank with a short description of sluice gate usage, i.e., for isolation of wastewater, or for tank drainage, or for control of water surface. 1.01

More information

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties Stainless steel describes a family of steels highly resistant to tarnishing and rusting that contain at least two

More information

Technical Specification for Live Line Tap Connectors

Technical Specification for Live Line Tap Connectors Ergon Energy Corporation Limited Technical Specification for Live Line Tap ETS-06-01-01 Check this is the latest Process Zone version before use. Specification ETS 06-01-01 Ver 1 Contents 1. Purpose and

More information

NUCLEAR. Nuclear Reactor Pressure Vessel Seals

NUCLEAR. Nuclear Reactor Pressure Vessel Seals NUCLEAR Nuclear Reactor Pressure Vessel Seals SEALING CONCEPT Technetics Group is the world s leading manufacturer of Nuclear Reactor Pressure Vessel (RPV) Closure Head Seals. In addition, Technetics Group

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe MEGALUG Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts Nominal

More information

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

MASTERSPEC - SHORT FORM. B. See Division 5 Section Metal Stairs for steel tube railings associated with metal stairs. SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated

More information

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free WAGO CAGE CLAMP Technology, Can Help Reduce Costs and Increase Safety in Your Applications! Contents Reduce Costs 4 Increase

More information

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4 x 4 x 3/8 Brace. C8 x 4.25 Strut. WT9 x 17.5. Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution DURA-BLOK rooftop supports BRTS-17 B-LINE SERIES DURA-BLOK A complete rooftop support solution DURA-BLOK rooftop solutions support DURA-BLOK supports are made of 100% recycled rubber and are designed to

More information

TUFFALOY. Resistance Welding Products. Leader in the Industry Since Catalog 2014

TUFFALOY. Resistance Welding Products. Leader in the Industry Since Catalog 2014 Catalog 2014 Resistance Welding Products Leader in the Industry Since 1937 Resistance Welding Equipment & Supplies Service Sales Consulting Seminars table of contents RESISTANCE WELDING PRODUCTS The little

More information

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv K-LINE INSULATORS LIMITED TORONTO, ONTARIO, CANADA Catalogue D-DS DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv ISO9001 SAI GLOBAL FILE No. 000117 Distribution Silicone Insulators

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

7Terminals and Splices

7Terminals and Splices Introduction Product Facts No need f inhibit agents, thanks to our dry crimp technique Terminating/splicing capabilities f stranded aluminum wire, plus splicing of aluminum wire to copper wire conducts

More information

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number:

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number: Catalog number: / / Electrical Module Finish See page 2 Specifications Dimensions Models 50 to 70 watt HID Medium Base Lamps 13 to 42 watt Compact Fluorescent 60 watt Incandescent 150 watt Halogen 27 LED

More information

DURA-BLOK is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility.

DURA-BLOK is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility. is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility. Channels are through bolted on all sizes for added strength and a 1

More information

INDUSTRIAL TEMPERATURE SENSORS

INDUSTRIAL TEMPERATURE SENSORS Temperature s INDUSTRIAL TEMPERATURE SENSORS Temperature s APPLIED SENSOR TECHNOLOGIES A DIVISION OF UNITED ELECTRIC CONTROLS T E M P S E N S O R - B - 0 2 Temperature s Temperature s index Subject Page

More information

DURA-BLOK Rooftop Supports

DURA-BLOK Rooftop Supports Cooper B-Line s new line of DURA-BLOK products gives you a versatile and long-term solution for all your roof top support needs. Designed with flexibility in mind, Dura-Blok is ideal for roof top support

More information

Section 906. STRUCTURAL STEEL

Section 906. STRUCTURAL STEEL 906.01 Section 906. STRUCTURAL STEEL 906.01. General Requirements. Finished rolled shapes must be free from imperfections that affect strength and durability in accordance with ASTM A 6. Rolled shapes

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : PHM-12 ARC WELD GUN PART NO. : PHM-12 (PHM-12-RS) SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@

More information

ROLLING RACK. Simple Security

ROLLING RACK. Simple Security Simple Security The graceful design and high security of the Rolling Rack has made this type of bike rack a standard for many schools and communities. The Rolling Rack can be used as a single-sided or

More information

Fixings, bonds and clamps

Fixings, bonds and clamps Square tape clamp Material 25 x 3mm Copper 0.12kg CT105-H 25 x 6mm Copper 0.30kg CT110-H 50 x 6mm Copper 0.60kg CT115-H Manufactured from high quality copper and aluminium alloys. Simple to install, providing

More information

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket

SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket 1993 Specifications CSJ 0331-04-045 SPECIAL SPECIFICATION 4900 Sacrificial Cathodic Protection Pile Jacket 1. Description. This Item shall govern for the furnishing, installing and energizing a sacrificial

More information

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4. Installation, Operation, and Maintenance Instructions MODEL 3200 / 3201 March 2002 CONTENTS 1.0 GENERAL 1.1 Model Number ----------------------------------------------------------------------------------------------

More information

Box Rail. Single Box Rail Bracket

Box Rail. Single Box Rail Bracket HANGERS & RAILS Box Rail Accordion Door Hangers Max. Door Weight (SWL) 450 lbs Meets ANSI/BHMA A156.14, Grade 1. Rail is carefully formed to give an even tread to hanger wheels. Packaging: Bundled without

More information

GroundTrac. Installation Manual

GroundTrac. Installation Manual APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

Features 1.34 In Width X 1.53 In Height X 1.13 Recp gang Stainless Steel/304 Stainless Steel

Features 1.34 In Width X 1.53 In Height X 1.13 Recp gang Stainless Steel/304 Stainless Steel 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 93101 1G 430SS Receptacle Plate Cooper Wiring Devices Catalog Number 93101 Manufacturer

More information

American Metal Specialties, Inc.

American Metal Specialties, Inc. American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information