4 N E X T G E N E R A T I O N
|
|
- Mark Higgins
- 5 years ago
- Views:
Transcription
1 N X T N R A T O N lectronically nhanced Solenoid Valves rass and Stainless Steel odies 1/" - 2" NPT 2/2 3/2 /2 SRS eneration eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement) Lower power operation Voltage ranging uilt-in surge suppression limination of A hum ncrease in A and operating temperatures Low solenoid temperature rise Longer coil life due to lower operating temperatures and electrical surge suppression Solenoid approvals to UL, SA, and directives Available with lass, ivision 2 coils ( prefix) RoS 2 ompliant Nominal Ambient Temp. Ranges 1 to 10 (-10 to 60 ) or 8262/8263/831 Series: -13 to 10 (-25 to 60 ) ow to order ind the valve that you are looking for in the provided specifications tables. The tables contain the following information designed to help you in making your selection: Pipe Size Orifice ia. v low ^ ) Operating Pressure ifferential (psi) Max. Agency Air-nert as Water Light 300 SSU Max luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ Agency Wattage Approx. Shipping Weight (lbs.) Min. 1/2 5/ P09 m When ordering a valve product, specify the ASO base catalog number (x. 8210P09). This number will always be 8 digits long. hoose one of the three operating voltage ranges (100-20V/50-60z/, 2-120V/50-60z/ or 12-2/) and add it to the base catalog number (x. 8210P V/50-60z/). f you want to enhance the product with one or more of the options allowed in the Optional eatures hart for that catalog number, please add the appropriate prefix or suffix (as shown): LTRONALLY NAN Pipe Size Orifice ia. Solenoid Options ase atalog Number Resilient Materials Other Standard Rebuild Kit lass, ivision 2 oil rass Stainless Steel NR KM 1/2 5/8 8210P09 - l V J N - - V MO M Optional lass, ivision 2 solenoid (x. 8210P V/50-60z/) f an KM elastomer and manual operator are required, add VMO to the back of the base catalog number. (x. 8210P09VMO 2-120V/50-60z/) When ordering a rebuild kit for a valve, supply the rebuild kit number as shown in the table. (x ) When ordering a rebuild kit for a valve with a suffix, add the suffix to the appropriate standard rebuild kit. (x. The rebuild kit for the above valve with KM is V) All constructions are available with prefix for lass, ivision 2 requirements. PM R Oxygen Service PT Urethane Vacuum Manual Operator Mounting racket rass Stainless Steel When ordering a replacement coil, select from the following: Voltage Range Valve Prefix Replacement oil Part Number V/50-60z/ * 2-120V/50-60z/ * 12-2/ * V/50-60z/ * 2-120V/50-60z/ * 12-2/ * Solenoid nclosures Standard: Watertight, Types 1, 2, 3, 3S,, and X. Optional: lass, ivision 2 for azardous Locations and Watertight, Types 3, 3S,, X. (To order, add prefix to catalog number.) Note See ngineering Section for valve parts in contact with fluids and additional information. 105
2 2/2 3/2 /2 SRS eneration LTRONALLY NAN 2-Way eatures Two-way (2/2) eneration solenoid valves have one inlet port and one outlet port ontrol of air, water, light oil, and non-corrosive media Normally closed (opens when energized) and normally open (closed when energized) operation Pipe sizes 1/8 to 2 inch Operating Pressure ifferential (psi) 2-Way Specifications (nglish units) Pipe Size 106 Orifice ia. v low Min. Air-nert as Max. Water Max Agency Agency Wattage Light 300 SSU luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ eneral Service - Normally losed 1/8 3/ R175 ƒ 1 l 1/8 3/ R099 ƒ 1 l /8 3/ R277 1 m 8262R178 1 m 1/8 1/ R105 1 m 8262R17 1 m 1/8 1/ R077 1 m / 3/ R107 ƒ 2 l / 3/ R181 ƒ 2 l 1/ 3/ R109 2 m 8262R183 2 m 1/ 1/ R232 2 m 8262R185 2 m 1/ 5/ R202 2 m 8262R220 2 m 1/ 7/ R208 2 m 8262R226 2 m 1/ 9/ R212 2 m 8262R230 2 m 1/ 9/ R078 2 m / 5/ P /8 1/ R115 3 m 8263R191 3 m 3/8 5/ R200 3 m 8263R193 3 m 3/8 7/ R12 3 m 8263R332 3 m 3/8 9/ R210 3 m 8263R333 3 m 3/8 5/ P /8 5/ P093 m /8 5/ P006 l /2 3/ P P /2 5/ P09 m /2 5/ P087 7 l 1/2 5/ P007 m / 5/ P088 7 l 3/ 3/ P095 7 m / 3/ P003 8 m / 3/ P P00 10 m / 1 1/ P m /2 1 1/ P m / P l eneral Service - Normally Open 1/8 3/ R155 ƒ 1 l 8262R168 ƒ 1 l 1/8 3/ R156 1 l 8262R169 1 l 1/8 3/ R128 1 l 8262R236 1 l 1/8 1/ R129 1 l 8262R237 1 l 1/ 3/ R161 ƒ 2 l 8262R199 ƒ 2 l 1/ 3/ R260 2 l 8262R130 2 l 1/ 3/ R261 2 l 8262R13 2 l 1/ 1/ R262 2 l 8262R138 2 l 1/ 5/ R263 2 l 8262R12 2 l 1/ 7/ R26 2 l 8262R18 2 l 1/ 9/ R265 2 l 8262R152 2 l 3/8 1/ R070 3 l 8263R080 3 l 3/8 5/ R071 3 l 8263R081 3 l 3/8 7/ R072 3 l 8263R082 3 l 3/8 9/ R073 3 l 8263R083 3 l 3/8 5/ P l /2 5/ P03 15 l / 3/ P l / 3/ P l m = Safety Shut-off Valve. l = eneral Purpose Valve
3 2/2 3/2 /2 SRS eneration 2-Way Specifications (Metric units) Operating Pressure ifferential (bar) Pipe Orifice Kv low Max. Max Agency Agency Wattage Size ia. (mm) actor (m 3 /h) Min. Air-nert as Water Light 300 SSU luid Temp. rass onst. Ref. UL Stainless Steel onst. Ref. UL A/ eneral Service - Normally losed 1/ R175 ƒ 1 l 1/ R099 ƒ 1 l / R277 1 m 8262R178 1 m 1/ R105 1 m 8262R17 1 m 1/ R077 1 m / R107 ƒ 2 l / R181 ƒ 2 l 1/ R109 2 m 8262R183 2 m 1/ R232 2 m 8262R185 2 m 1/ R202 2 m 8262R220 2 m 1/ R208 2 m 8262R226 2 m 1/ R212 2 m 8262R230 2 m 1/ R078 2 m / P / R115 3 m 8263R191 3 m 3/ R200 3 m 8263R193 3 m 3/ R12 3 m 8263R332 3 m 3/ R210 3 m 8263R333 3 m 3/ P / P093 m / P006 l / P P / P09 m / P087 7 l 1/ P007 m / P088 7 l 3/ P095 7 m / P003 8 m / P P00 10 m / P m / P m P l eneral Service - Normally Open 1/ R155 ƒ 1 l 8262R168 ƒ 1 l 1/ R156 1 l 8262R169 1 l 1/ R128 1 l 8262R236 1 l 1/ R129 1 l 8262R237 1 l 1/ R161 ƒ 2 l 8262R199 ƒ 2 l 1/ R260 2 l 8262R130 2 l 1/ R261 2 l 8262R13 2 l 1/ R262 2 l 8262R138 2 l 1/ R263 2 l 8262R12 2 l 1/ R26 2 l 8262R18 2 l 1/ R265 2 l 8262R152 2 l 3/ R070 3 l 8263R080 3 l 3/ R071 3 l 8263R081 3 l 3/ R072 3 l 8263R082 3 l 3/ R073 3 l 8263R083 3 l 3/ P l / P03 15 l / P l / P l m = Safety Shut-off Valve. l = eneral Purpose Valve LTRONALLY NAN 107
4 2/2 3/2 /2 SRS eneration 2-Way Optional eatures hart ase atalog Number Resilient Materials and Suffix Options Other Standard Rebuild Kit LTRONALLY NAN Pipe Size Orifice ia. rass Stainless Steel Ammonia Silicone ree ry Air NR LT NR KM 1/8 3/6 8262R099 ƒ 8262R175 ƒ - S l - - M W W 1/8 3/6 8262R155 ƒ 8262R168 ƒ - S l - - M W W 1/8 3/6 8262R R169 N S - l A V J N T M /8 3/ R R178 N S - l A V J N T - MS M /8 3/ R R236 N S - l A V J N T M /8 1/8 8262R R17 N S - l A V J N T - V MS M /8 1/8 8262R S - - l M /8 1/8 8262R R237 N S - l A V J N T - V - M / 3/6 8262R107 ƒ 8262R181 ƒ - S l - - M W W 1/ 3/6 8262R161 ƒ 8262R199 ƒ - S l - - M W W 1/ 3/6 8262R R130 N S - l A V J N T M / 3/ R R183 N S P l A V J N T - - MS M / 3/ R R13 N S - l A V J N T M / 1/8 8262R R18 N S P l A V J N T - - MS M / 1/8 8262R R138 N S - l A V J N T M / 5/ R R220 N S P l A V J N T - - MS M / 5/ R R12 N S - l A V J N T M / 7/ R R226 N S P l A V J N T - - MS M / 7/ R R18 N S - l A V J N T M / 9/ R R230 N S P l A V J N T - V MS M / 9/ R R152 N S - l A V J N T - V - M / 9/ R S - - l M / 5/ P l A /8 1/8 8263R R191 N S - l A V J N T - - MS M /8 1/8 8263R R080 N S - l A V J N T M /8 5/ R R193 N S - l A V J N T - - MS M /8 5/ R R081 N S - l A V J N T M /8 7/ R R332 N S - l A V J N T - - MS M /8 7/ R R082 N S - l A V J N T M /8 9/ R R333 N S - l A V J N T - - MS M /8 9/ R R083 N S - l A V J N T M /8 5/ P l /8 5/8 8210P l - V J N - - V MO M /8 5/8 8210P l - V J N - - V - M /8 5/8 8210P l - V J N MO M /2 3/8 8223P P l /2 5/8 8210P l - V J N - - V MO M /2 5/8 8210P l - V J N - - V - M /2 5/8-8210P l - V J N MO M /2 5/8 8210P l - V J N MO M / 5/8-8210P l - V J N MO M / 3/ 8210P l - V J N - - V MO M / 3/ 8030P l - V J N MO M / 3/ 8210P l - V J N - - V - M / 3/ 8030P l - V J N M / 3/ 8223P l P l - V J N MO / 1 1/8 8210P l - V J N MO /2 1 1/ 8210P l - V J N MO / 8210P l - V J N MO l = Standard. Other options may be available. All option combinations may not be available. Please consult your local ASO contact. Valve contains PT main disc; Pressure rating reduced by 25%; Pressure rating limited to 250 psi; Valve contains Nylon 11 piston. ƒ ast UR disc supplied as standard, limits min. ambient temp. to 32 (0 ). uel gas service only; Ambient Temp. -0 to 10, luid Temp. -0 to 167 ; as capacity for 8262R077 is 18,700 tu/hr, for 8262R078 53,500 tu/hr based on 1" W.. 2" W.. nlet Pressure, 1000 tu/cu.ft. or more, 0.6 Specific ravity as. N suffix only available for Stainless Steel constructions. 12-2V V A/, V A/. PM R Oxygen Service PT Urethane Vacuum Manual Operator Mounting racket rass Stainless Steel 108
5 2/2 3/2 /2 SRS eneration imensions: inches (mm) onst. Ref. 1 in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm [8].69 [18] MOUNTN OLS LOW onst. Ref. 1 ANPT OT NS.59 [15] MOUNTN OLS M5 TRA.25 [6.] MN. ULL TRA PT. 2 OLS OR MOUNTN. onst. Ref. 2 ANPT OT NS LTRONALLY NAN.3 [9].87 [22.2] MOUNTN OLS.87 [22.2] MOUNTN OLS onst. Ref. 3 LOW M5 TRA.30 [7.6] MN. ULL TRA PT. 2 OLS OR MOUNTN. onst. Ref., 7, 15, 16, 17 ANPT OT.57 [1].75 [19] MOUNTN OLS.81 [20.6] MOUNTN OLS LOW M5 TRA.2 [6] MN. ULL TRA PT. 2 OLS OR MOUNTN ANPT OT NS PORT 2 109
6 2/2 3/2 /2 SRS eneration imensions: inches (mm) onst. Ref. 5, 6, 9 onst. Ref. 8 LTRONALLY NAN onst. Ref. 10 onst. Ref. 11, 12 onst. Ref. 18 ANPT OT NS 110
7 ngineering nformation eneration lectronically nhanced Solenoids ( eneration) All Redat eneration solenoid valves are rated for continuous duty under the operating conditions outlined within this section. oil Operating Voltage Ranges All coils are designed for industrial operating voltages and can be used on the following voltage ranges: Voltage Range Minimum Voltage Maximum Voltage V/50 or 60z/ lectrical Specifications 2 Watt lectronic oils Type Maximum Ambient Temperature 10 Maximum ycle Rate Standard oil lass of nsulation 1 Operation/ Second Power onsumption The eneration solenoid power rating is 1.0 watt of power for 12-2V and 1.5 watts for 2-120V A/, and V A/ V/50 or 60z/ / only The coils with voltage ranges of and 2-99 have three lead wires, 2 inches long (2 red for power input, and one green lead for grounding where necessary). These two versions are not polarity sensitive. The coil with a voltage range of 12-2/ has 3 lead wires, one red, one black, and one green. This coil is polarity sensitive. The red lead is the positive, black is the negative, and green is the ground wire. This solenoid is also polarity protected. Reversing the polarity will not damage the coil, but the coil will not function until the correct polarity is applied. Note: The voltage range is also suitable for battery charging circuits designed around a 125/ nominal voltage range. Magnet wire - lass insulation Lead wire - UL and SA listed 600 volt leads, 6 strand, 18awg, P coated Overmold LP obbin-lp 85 NNRN
8 ngineering nformation eneration The advanced technology used in the eneration coil includes electronic circuitry which may limit the compatibility with certain control system components. The following issues need to be considered when specifying an output card or device to operate the eneration coil. An initial inrush current spike is drawn by the eneration coil. This inrush spike is 72 msec in duration, which is sufficient time for the core to reach the plugnut. The electrical requirement then drops to the holding value. nrush urrent: The power source, wiring, and output device used need to have surge ratings equal to or greater than the inrush current value (appropriate to the voltage range) specified in the table below. nrush urrent Rating oil Version Peak nrush urrent (Amps) 12-2/ /50-60z/ /50-60z/ 0.32 Maximum uration = 72 ms olding urrent: The power source, wiring, and output device used need to have continuous current ratings equal to or greater than the holding current value (appropriate to the voltage range) specified in the table below. The eneration coil is suitable for systems using supervisory currents that do not exceed the drop-out currents noted in the table below. Supervisory/Leakage urrent Rating oil Version rop-out urrent (ma) 12-2/ /50-60z/ /50-60z/ 7 mportant: Supervisory and leakage currents above the drop-out current listed with cause improper operation. onsult your local ASO Sales office for additional assistance. Solenoid nclosures The eneration solenoid coil is fully encapsulated using upont Zenite Liquid rystal Polymer resin (LP). Zenite (LP) is a thermoplastic polyester resin which exhibits several advantages over other thermoplastics. The advantages include excellent resistance to a wide range of organic solvents and automotive fluids*, resistance to impact, and long term retention of properties at continuous-use temperatures. *hemical resistance of Zenite LP may not be suitable for all applications. Zenite LP is not suitable for caustic solution. Please consult ASO for appropriate product solutions. Zenite is a registered Trademark of upont o. olding urrent Rating NNRN 86 oil Version 12-2/ 2-120/50-60z/ /50-60z/ nput Voltage Average olding urrent (Amps) Average olding Volt-Amps (VA) Supervisory/Leakage urrents: The leakage current is defined as a current that is supplied from an output device when the device is in its off or de-activated state. Redat eneration Solenoids are available as: eneral Purpose/Watertight ntended for indoor and outdoor use and provides protection classifications from NMA Types 1 through X. lass, ivision 2 for azardous Locations/Watertight Meets Types 1 through X and is UL listed and SA certified for lass, ivision 2, roups A,,, and and lass, ivision 2, roups and. Operating temperature code TA (120 ).
9 ngineering nformation eneration Valve Specifications Maximum Ambient Temperature The maximum ambient temperature is 10 (60 ). This limit is based on continuous energization with the maximum fluid temperatures as shown on each catalog page. Response Time Response time from fully closed to fully open or vice versa depends on valve size, operating mode, fluids, temperature, inlet pressure, and pressure drop. The response times for eneration are defined as: Small direct acting valves 10 to 60 msec Large direct acting valves 25 to 90 msec nternally pilot operated valves: - Small diaphragm types 20 to 100 msec - Large diaphragm types 80 to 150 msec - Small piston types 80 to 150 msec - Large piston types 105 to 200 msec Operation on liquids has relatively little effect on small direct acting valves, however, response times of large direct acting and internally piloted valves may be lengthened by 50% to 100%. Manual Operators Manual operators are provided to operate the valves manually when electric actuation is not provided. There are two basic types of manual operators, momentary and maintained. To determine which type of manual operator is available for your valves, please see the Optional eatures hart on the relevant valve catalog page. Once it is determined that the subject valve can accommodate a manual operator, the chart below will tell you the type of manual operator. The chart also references the relevant cutaway illustration. utaway llustrations Series Number onst. Ref. Manual Operator Suffix Manual Operator Type llustration Number MO Maintained , 7, 10, 11, 12 MO Maintained MS Maintained MS Maintained MS Maintained , 6 MO Maintained MO Momentary MS Maintained MO Momentary MS Maintained , 3, MO Maintained MO Maintained 5 87 NNRN
10 ngineering nformation eneration Valve Parts in ontact with luids Series ody Seals and iscs isc older ore uide Springs Shading oil 8030 rass NR Stainless Steel opper Stainless Steel NR Stainless Steel Silver rass NR Stainless Steel opper Stainless Steel PT, NR Stainless Steel Silver rass NR, PA, PT Stainless Steel opper Stainless Steel NR Stainless Steel Silver 8262P Stainless Steel UR Stainless Steel Silver 8262R Stainless Steel UR Stainless Steel Silver 8262R Stainless Steel UR Stainless Steel Silver 8262R Stainless Steel UR Stainless Steel Silver 8262R Stainless Steel UR Stainless Steel Silver 8262 rass NR Stainless Steel opper 8262R077 rass LT NR - - nconel opper 8262R078 rass LT NR - POM nconel opper Stainless Steel NR Stainless Steel Silver 8263 rass NR Stainless Steel opper Stainless Steel NR, KM - POM 302 Stainless Steel Silver 831 rass NR, KM - POM 302 Stainless Steel opper 8316 rass NR POM POM 302, 17-7P Stainless Steels opper 8317 rass NR, KM, R - POM 302, 17-7P Stainless Steels opper Stainless Steel NR POM POM 302 Stainless Steel Silver 8320 rass NR POM POM 302 Stainless Steel opper 8321 rass NR POM POM 302 Stainless Steel opper 83 rass NR POM POM 302, 17-7P Stainless Steels opper 835 rass NR, PA - POM 302 Stainless Steel opper Stainless Steel NR, PA - POM 302 Stainless Steel opper 8551 Anodized Aluminum NR, PA - POM 302 Stainless Steel opper Note: All core tubes are 305 stainless steel and all cores and plugnuts are 30 stainless steel. 8210P033, 8210P03, and 8210P035 with PA isc older NNRN 88
4 N E X T G E N E R A T I O N
N X T N R A T O N lectronically nhanced Solenoid Valves rass and Stainless Steel odies 1/4" - " NPT / 3/ 4/ SRS eneration eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement)
More informationElectronically Enhanced Solenoid Valves
lectronically nhanced Solenoid Valves ( eneration) Redat eneration is the future of solenoid valve technology, designed and manufactured to provide new capabilities. The eneration of solenoid valves provides
More information/ 3/ 4/ SRS eneration 3-Way eatures Three-way (3/) eneration solenoid valves have three ports and two orifices. When one orifice is open, the other is
N X T N R A T O N lectronically nhanced Solenoid Valves rass and Stainless Steel odies 1/4" - " NPT / 3/ 4/ SRS eneration eatures ncrease in pressure ratings to A levels on all products (up to a 500% improvement)
More information2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical
ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel
More informationSPEIFITIONS pipe orifice flow coefficient Kv operating pressure differential (bar) level BP prefix optional solenoids basic catalogue number max. (PS)
SOLENOI VLVES direct operated core disc /4 N U NO / Series 4 FETURES ompact valve intended for single-acting actuator control coil for general service applications oils interchangeable without dismantling
More informationP630 HIGH FLOW GAS REGULATOR
P60 HIGH FLOW GAS REGULATOR P60 HIGH FLOW GAS REGULATOR Stainless Steel Internals are Standard Steel Units comply with NACE MR0 Durable Powder Coated Exterior Wide Range of Flow Capacities The P60 is a
More informationTechnical Data Body Construction Materials Aluminum, brass, steel, 303 or 316 stainless steel O-ring Materials
200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing
More informationMiniature I/P, E/P Transducer
Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional
More informationRCI 400 Series Actuators
PNEUMATIC RCI 400 Series Actuators TECHNICAL DATA SHEET The Remote Control RCI 400 Series offers a lower cost alternative to our highly successful scotch yoke design. The addition of this product broadens
More informationDisplacer Type Liquid Level Switches
isplacer Type Liquid Level es S R I P T I O N Magnetrol displacement type level switches offer the industrial user a wide choice of alarm and control configurations. very unit utilizes a simple buoyancy
More informationASME Code Filter Vessels Compressed Air & Gas Filtration
SME ode Filter Vessels ompressed ir & Gas Filtration Large apacity SME Vessels Finite's filter vessels eliminate oil, water, and particulate contamination from large flows of compressed air and gas. Finite
More informationP600 Pressure Regulator
P00 Pressure Regulator The BelGAS P00 series is a direct operated, pressure reducing regulator that can be used as a pressure loaded regulator, switching valve, or monitoring regulator. Available with
More informationGUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems.
INSTRUMENTATION SPECIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationSolenoid valve 2/2 way N.O. With pilot control
Solenoid valve 2/2 way N.O. With pilot control 21W3Z190 21W7Z500 PRESENTTION: S.V. with pilot control for interception of fluids compatible with the construction materials. minimum operational pressure
More informationASME Code Filter Vessels
SME ode Filter Vessels ompressed ir & Gas Filtration Large apacity SME Vessels Finite's fi lter vessels eliminate oil, water, and particulate contamination from large fl ows of compressed air and gas.
More informationDCV Wafer check valves
V Wafer check valves V wafer check valves to prevent reverse flow... The Spirax Sarco range of V wafer check valves provides an effective minimal maintenance free solution for the prevention of reverse
More informationACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4
ESSORIES LT000 lock form flow regulators (uni-directional) /8 & /4 LT00 lock form flow regulators (bi-directional) /8 & /4 LT70 Quick exhaust valves /8 & /4 LS/50, L/50 Heavy duty non-return valves /4...
More informationMaximum Inlet Pressure. 400 psig (27,6 bar), For higher inlet pressures, up to 1000 psig (69 bar), see Bulletin 71.2:99.
Introduction Maximum Inlet Pressure The Type 99 regulator typically provides fuel gas to boilers, furnaces, ovens, mixers, and large commercial or institutional installations. 400 psig (27,6 bar), or higher
More informationUNIVERSAL PRODUCT LINE: STAINLESS STEEL MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
SERIES 827A Section 703 Page 703. TABLE OF CONTENTS Features & Benefits...2 Model Number Key...2 Port Location Options...2 Cutaway View & Pump Features...3 Materials of Construction...4 Special Materials
More informationUNIVERSAL PRODUCT LINE: CAST IRON MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
UNIVERSAL PRODUCT LINE: SERIES 8124A Section 1403 Page 1403.1 Issue A TABLE OF CONTENTS Features & Benefits...2 Model Number Key...2 Materials of Construction...4 Special Materials & Options Selection
More informationMicro Hydro Electric Generators
Micro Hydro Electric Generators Harris Pelton Turbines ES and D Turgo Generators Pressure Drop in Pipe Flow Rate Through Various Nozzles We offer a variety of small hydroelectric generators that are designed
More informationVIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.
Page 635.1 Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps Operating 1: Series 8124A Model H8124A Nominal Flow Temp. 2 Viscosity (GPM) 15-200 (M 3 /hr.) 3.4-45 (PSI) To 200 PSI (Bar) To 14 Bar (
More informationPRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES
Master Pneumatic regulators are made in a wide range of sizes to suit nearly all industrial requirements for pneumatic pressure regulation. Good pressure regulation is essential to the efficient use of
More informationdiaphragm valves DV1 Series 2-Way Diaphragm Valves Typical Applications Analytical Instrumentation Petrochemical Pharmaceutical Chemical
DV1 Series 2-Way Diaphragm Valves The DV1 Series Diaphragm Valves are totally free of springs, bellows, packing, o-rings and lubricants in the process wetted area. Metal-to-metal seals to atmosphere ensure
More informationService and installation must be performed by a trained/experienced service technician.
CATALOG DRAFT 09.18.2013 Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance
More informationnicrom e l e c t r o n i c
G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com
More informationHusky 515 Acetal AOD Pump
Husky 515 AOD Pump Please Contact Us With Any Questions 604 988 7151 sales@cpesystems.com www.cpesystems.com Husky 515 Plastic Pumps Air-Operated Double Diaphragm Ordering Information D X X X X X Diaphragm
More informationRosemount 1152 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment
More informationHEAVY-DUTY CAPPED SEAL
HEAVY-DUTY CAPPED SEAL Featuring special anti-extrusion technology TECHNICAL DETAILS The Hallite Capped T seal is a compact, double-acting, high-performance piston seal design capable of handling the high
More informationCOMBINATION AIR VALVE
MINING DIVISION COMBINATION AIR VALVE FOR HIGH FLOW D-6NS SERIES DESCRIPTION The D-6NS Series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The air release
More informationAccessories - Universal Safety Heads
Accessories - Universal Safety Heads Pressures to 110,000 psi (7584 bar) Safety Heads/Rupture Discs - Safety Heads and Rupture Discs offer an economical and dependable relief port to guard against system
More informationDP Series Low Pressure Pneumatic Diaphragm Valves 316L SS/ASTM A479. Machine finished. FC-01 Standard Cleaning and Packaging
iaphragm Valves iaphragm Valves V-0 P Series ow Pressure Pneumatic iaphragm Valves Features Minimum particle generation and dead space Fully contained seat to provide excellent resistance to swelling and
More informationVIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.
VIKING Section 635 Page 635.1 Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps Model H8124A Operating Range1: Series 8124A Nominal (GPM) 15-500 Flow (M 3 /hr.) 3.4-114 Pressure (PSI) To 200 PSI Range
More informationOverview. Benefits. Applications. Tantalum Through-Hole Capacitors Hermetically Sealed T252 Series Axial MIL PRF (CSR33 Style)
Tantalum Through-Hole apacitors Hermetically Sealed Overview The hermetically sealed T252 Series solid tantalum capacitors offer high capacitance-to-volume ratios and are offered in standard MIL style
More informationHusky 716 Aluminum. Please Contact Us With Any Questions
Husky 716 Aluminum Please Contact Us With Any Questions 604 988 7151 sales@cpesystems.com www.cpesystems.com Husky 716 Metal Pumps Air-Operated Double Diaphragm Ordering Information D X X X X X Diaphragm
More informationMSP300 Pressure Transducer
SPECIFICATIONS Analog Output or 14-Bit Digital Pressure with 11-Bit Temperature Output One Piece Stainless Steel Construction Low Cost 17-4PH or 316L Stainless Steel Customizable FEATURES One Piece Stainless
More informationTEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions
Technology Solutions TEK-B AR 3800E Multivariable Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Bar 3800E is an
More informationPolyethylene Tubing. Series E: Instrument Grade FDA, NSF Listed Series EB: Ultraviolet Light Resistant
Polyethylene Series : Instrument rade, NS Listed Series : Ultraviolet Light Resistant eatures Made from 100% virgin resin material hemically resistant and flexible High molecular weight resin provides
More informationTantalum Through-Hole Capacitors Hermetically Sealed T245 Series Axial High Temperature Solder (CSR23 Style)
Tantalum Through-Hole apacitors Hermetically Sealed Overview The KEMET standard MIL case hermetically sealed T245 Series (Extended apacitance Range) is compact, ruggedly built and designed for miniaturized
More informationMechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G
Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree
More informationSECTION GENERAL-DUTY VALVES FOR WATER-BASED FIRE-SUPPRESSION PIPING
PART 1 GENERAL SECTION 21 0523 GENERAL-DUTY VALVES FOR 1.01 SECTION INCLUDES A. Two-piece ball valves with indicators. B. Bronze butterfly valves with indicators. C. Iron butterfly valves with indicators.
More informationSAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.
SAF Filters flow rates filtration degrees water for cleaning min. operating pressure up to 400 m³/h (1760 US gpm) 800- micron less than 1% of the total flow bar (30 psi) The automatic self-cleaning filter
More informationDH Series High Pressure Springless Diaphragm Valves. Special Cleaning and Packaging 316L SS/ASTM A479. Machine finished
V-9 iaphragm Valves iaphragm Valves s Valves & Regulators H Series High Pressure Springless iaphragm Valves Features Metal-to-metal diaphragm seal Elgiloy diaphragm to provide high strength and corrosion
More informationpressure regulators Back Pressure Regulators
Back Pressure Regulators Index Safety Warning Inside Front Cover BP-3 Series 1 BP-6 Series 4 BP-8 Series 7 BP-8LF Series 10 CBP-3 Series 13 LB-1 Series 16 SBPR Series 19 BP-60 Series 22 BP-66 Series 25
More informationA REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
AIR OPERATED DOUBLE DIAPHRAGM PUMPS PRODUCT CATALOG A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
More information( )
(-800-49-886) OVERVIEW WATTCO tubular elements are the most versatile and best suited solutions to a large number of applications. This is why they are found in major modern heating applications and are
More informationTAF, SAF & EBS Screen Filters
TM ilters T, S & S Screen ilters Pre-engineered V iltration Solutions Self-cleaning, packaged filter systems designed to save you time and money flow rates filtration degrees inlet/outlet diameter operating
More informationFN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring
Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long
More informationSTANDARD RANGES (ALL INTERMEDIATE RANGES ARE STANDARD) Range (psi) Range (Bar) Gage/Compound 0 to to to to to to t
SPECIFICATIONS Analog Output or 14-Bit Digital Pressure with 11-Bit Temperature Output One Piece Stainless Steel Construction Low Cost 17-4PH or 316L Stainless Steel Customizable FEATURES One Piece Stainless
More informationdiaphragm valves Diaphragm Valves
Diaphragm Valves Index Safety Warning Inside Front Cover 2-way Diaphragm Valves Pneumatic Actuated Valves 4 DV Series- How to Order Matrix 7 Disclaimers Inside Back Cover GO Regulator PO Box 4866 Spartanburg,
More informationModulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING.
Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationFS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.
S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationAir Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants
N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard
More informationSeries Regulators - Pressure Reducing
26-1200 Series Regulators - Pressure Reducing D26120540X012 Specifications For other materials or modifications, please consult TESCOM. 3600 and psig 248 and 414 bar Outlet Pressure To maximum inlet Design
More informationpackless valves Packless Valves Index Bellows & Diaphragm
Packless Valves Bellows & Diaphragm Index 0300 Series (Bellows) 1 4100 Series (Bellows) 4 4200 Series (Bellows) 8 4500 Series (Bellows) 11 4600 Series (Diaphragm) 13 DV1 Series (Diaphragm) 17 HOKE PO Box
More informationParticulate Filters. Filter Function. Exclusive Dense Pack Element Design. Optional Components
Particulate ilters Inlet Outlet Monnier particulate filters remove solid and liquid contaminants from compressed air. The proper selection and use of compressed air filters will prevent many short and
More informationInstallation of CSST Gas Piping Systems
(What Inspectors Need To Know) May 2016 Conventional Arc-Resistant CSST Product Standard National Standard ANSI LC-1 Performance-based standard Listed system installed in accordance with manufacturer s
More informationHusky 307 Polypropylene AOD Pump
Husky 307 AOD Pump Please Contact Us With Any Questions 604 988 7151 sales@cpesystems.com www.cpesystems.com Husky 307 Plastic Pumps Technical Specifications Husky 307 Plastic Pumps Acetal Maximum fluid
More informationVAPORIZING REGULATORS
VAPORIZING REGULATORS Instrument/Analyzer Products Catalog 4512/USA October 2003 VAPORIZING REGULATORS Instrument/Analyzer Products Catalog 4512/USA October 2003 table of contents Veriflo Division...................
More informationThe system is capable of operating in (3) three modes, each with (2) two different dose modes.
Integrated Leachate Pumping Systems www.leachator.com info@leachator.com Introduction The Leach-Rite Dispersal System installed in your landfill is a unique system for dispersing leachate back into the
More informationRosemount 1153 Series D Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4388 Rev BA INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1974 and IEEE Std 344-1975 5.0 x 10 7 rads TID gamma radiation 7 g ZPA seismic 420 F (215.6 C) steam temperature
More informationVALVES. Prospector Series Poppet Valves 1/4" to 2" Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves
2 High flow - Cv of 1.2 to 49.5 Durable, robust construction Two mounting styles: inline or subbase 1/4" to 2" ports (SPP or PTF threads) Wide range of ir Pilot Operators available Four functional types:
More informationMEDIUM PRESSURE FILTERS LPF Series Inline Filters 725 psi up to 74 gpm
LPF Series Inline Filters 725 psi up to 74 gpm Hydraulic Symbol A B E6 Features LPF filters are manufactured with cast aluminum head and aluminum cold formed bowls. Aluminum alloy is water tolerant - anodization
More information8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.
SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional
More informationP133 Pressure Regulator
P33 Pressure Regulator Suitable for Monitoring Balanced Supply Valve Wide Pressure Range Offering The P33 is a direct operated pressure reducing regulator with external pressure registration used in commercial
More informationLIQUID LEVEL SWITCHES
LIQUID LEVEL SWITCHES Our Liquid Level switches come in a number of sizes and materials for use in a variety of industrial applications and other end-user solutions. Every switch is sealed with our patented
More information1604/2609/3609 TYPE 1604/2609/3609. First Edition API 682 Type C Sealol Metal Bellows Seals. Product Description. Performance Capabilities
A Inner Bellows Assembly B Insert C Inner Mating Ring D Packing E low Guide Inner Gland G Spiral Wound Gasket H Pumping Ring I Outer Bellows Assembly J Packing ollower K Sleeve L Outer Gland M Outer Mating
More informationKEYSTONE SERIES GR RESIlIENT SEATED BUTTERFly VAlVES GRF
A heavy duty double flanged concentric design resilient seated butterfly valve FEATURES GENERAL APPLICATION These valves are for water or air service where a drop-tight shut-off and double flanged body
More informationBaumann 16, 32, 54, and 70 Pneumatic Actuators
Baumann Pneumatic s Product Bulletin Baumann 16, 32,, and 70 Pneumatic s Baumann actuators are single acting, pneumatic actuators with spring-return action. They are compact, multi-spring actuators with
More informationPRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.
PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts
More informationAIR OPERATED DOUBLE DIAPHRAGM PUMPS
AIR OPERATED DOUBLE DIAPHRAGM PUMPS PRODUCT CATALOG A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
More informationTEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions
Technology Solutions TEK-B AR 3120B Smart Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Bar 3120B Smart Gauge
More informationCROSBY H-SERIES DIRECT SPRING SAFETY VALVES
DIRECT SPRING SAFETY VALVES Direct spring safety valves that provide comprehensive overpressure protection for ASME Boiler and Pressure Vessel Code Section I, and Section VIII steam safety applications
More informationCompressed Air Filters Sample Filters
Compressed Air Compressed Air Sample Balston Sample Protect Sensitive Analyzers Balston Gas and Liquid Sample Analyzer protect analyzers from sample impurities by removing solids and liquids from gases
More informationflow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow
Pelmar Engineering Ltd. Tel. (888) 754-639, (416) 88-1736 E-mail: sales@pelmareng.com Web site: www.pelmareng.com SAF Filters The automatic self-cleaning filter - suitable for more applications than ever
More informationBulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators
Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...
More informationTUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU
TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact
More informationExternal Cage Displacer Actuated Liquid Level Switches
xternal age Displacer ctuated Liquid Level Switches D S R I P T I O N High Pressure Liquid Level Switches are displacer actuated units, utilizing a single switch mechanism for level alarm or control functions.
More informationAPT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)
Range and Sensor Limits Refer to Table 1 Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum
More informationD5100 Industrial Differential Pressure Transducer
316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections DESCRIPTION The
More informationRS232 & RS449 Compatible
Press 89 Series D Sub.109" x " Grid SPIFITIONS RS232 & RS449 ompatible Press D-Subminiature connectors are preassembled for easy one-step assembly to the board. ontacts are individually removable and replaceable
More informationThe T262 Series is ideal for filtering applications and in defense power supplies where low ESR is essential.
Tantalum Through-Hole apacitors Hermetically Sealed Overview KEMET s T262 Series (SR21 Style) hermetically sealed solid tantalum capacitors are qualified to MIL 39003/09. This series is similar to KEMET's
More informationCONOFLOW HIGH-PRESSURE REGULATOR - HP500 Pressure Reducing - Diaphragm Type - High Purity
CONOFLOW HIGH-PRESSURE REGULATOR - HP500 Pressure Reducing - Diaphragm Type - High Purity The HP500 Regulator is a self-contained, diaphragm sensing high purity regulator. A broad offering of materials
More informationLow Pressure Molding Overview. Henkel Electronics
Low Pressure Molding Overview Henkel Electronics Agenda 1 Technology 2 Process 3 Solutions 2 Agenda Low Pressure Molding Overview of Technology Definition Value Proposition Applications Processing Equipment
More informationDistinctive Characteristics
Distinctive Characteristics Power and logic level capabilities available to suit varying applications. Light Duty Miniature Toggles Series E High torque bushing prevents rotation and separation from metal
More informationD-060 PN 16 D-060-C PN 16 D-062 PN 25 D-065 PN 40. A.R.I. FLOW CONTROL ACCESSORIES Ltd. Combination Air Valve for High Flow. Description.
D-00 PN Water Supply D-00- PN D-0 PN D-0 PN 0 ombination ir Valve for High Flow us-d00wtr- Description The D-00 series ombination ir Valve has the features of both an air release valve and an air & vacuum
More informationSECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE
METAL-ENCLOSED BUS MEDIUM VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install the equipment as specified herein and as shown on the contract drawings. The medium
More informationTechnical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications
Technical Datasheet Pressure Switch Models: CS2 & CS4 Key Features Compact and rugged design. Stainless steel weatherproof enclosure IP66 / NEMA 4X Hermetically sealed SPDT or microswitch ATEX / IECEx
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals
More informationSECTION CHEMICAL FEED SYSTEM
SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary
More informationEBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow
EBS Filters flow rates filtration degrees water for cleaning min. operating pressure up to 7200 m³/h (32000 US gpm) 800-10 micron less than 1% of the total flow 2 bar (30 psi) The largest automatic self-cleaning
More information3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white
3-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A a b c d e f a c (cont d) e (cont d) f (cont'd) Protection Rating
More informationCompressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features
Compressed Coalescing Balston Microfiber Filter Assemblies Balston Coalescing Compressed protect your equipment and delicate instruments from the dirt, water, and oil usually found in compressed air. Balston
More informationFloat valves Types SV 4, SV 5 and SV 6
Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia
More information5100 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction
5100 SERIES HERMETICALLY SEALED THERMOSTAT PROBE Introduction The 5100 series is a single pole, single throw, snap-action, hermetically sealed temperature control designed for applications requiring high
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE N.J. Specification No. Effective Date: July 1, 2001 New
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More information