1 FS and FD Cast Device Boxes: Malleable Iron, Aluminum B Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles Compliance: CSA Listed

2 B-2

3 B-3 FS and FD Cast Device Boxes: Index Page Description 4-6 Single-Gang Device 4 Features 7, 8, 9 Covers 9 Covers, Locking 6 Dimensions 9 Plugs 9 Plugs, Locking 9, 14 Plug Receptacle Covers 10 Two-Gang Device 11 Covers 10 Dimensions 12 Three-Gang Device 12 Covers 12 Dimensions 13 Four-Gang Device 13 Covers 13 Dimensions 13 Gaskets Hubless Device 17 Dimensions 18, 19 Hub Arrangements 20 Pedestal Mounted Receptacles/Breakers

4 B-4 FS and FD Cast Device Boxes: Malleable Iron, Aluminum Applications Accommodate wiring devices such as switches and receptacles. Provide excellent service in areas where boxes are subject to rough usage. Serve as pull boxes for conductors. Permit access to conductors for maintenance. Provide openings for making splices. Allow connections for branch conduit runs. FS and FD blank bodies for special conduit-entrance arrangements. Features: All FS and FD Boxes Corrosion-resistant ideal for indoor and outdoor installations. Weatherproof, raintight and dust-tight when used with cast gasketed covers. FS and FD boxes take standard flush wiring devices. FD boxes take devices exceeding 1-5/8 in depth under fastening ears. Malleable iron for high tensile strength and ductility provides greater resistance to impact and shock. Both malleable iron and aluminum boxes have ridge top construction for positive cover/gasket/box fit. Accurately tapped, tapered threads for tight, rigid joints, ground continuity. Complete selection of covers, receptacles, plugs, gasket and accessories. Covers have captive stainless steel screws to speed installation, prevent freezing of screws. Ground screw at top of box for easy access. Features: Cast Hub Boxes Available in single, two and three gang and tandem. Smooth, rounded integral bushing in each hub protects conductor insulation. Features: FD Blank Bodies for Brazed Hubs or Drill and Tapped Entries Available in single, two, three and four gang boxes. Drill and tapped entries. Brazed threaded hubs for threaded conduit from 1/2" thru 1-1/2" and brazed union hubs from 1/2" thru 1-1/4". Smooth, rounded integral bushing in each hub protects conductor insulation. Ground screw at top of box for easy access. Standard Materials Cast Hub Device Boxes and Boxes for Drilling and Tapping: malleable iron or copper-free (4/10 of 1% max.) aluminum. Brazed Hubs: malleable iron. Covers: malleable iron, steel, or copper-free (4/10 of 1% max.) aluminum. Standard Finishes Malleable Iron Device Boxes: triplecoat (1) zinc electroplate, (2) dichromate, and (3) aluminum polymer enamel. Aluminum Device Boxes: aluminum polymer enamel. Malleable Iron Covers with Gaskets: triple-coat (1) zinc electroplate, (2) dichromate, and (3) aluminum polymer enamel. Steel Covers: zinc electroplate. Aluminum Covers: aluminum polymer enamel. Compliances CSA approved. Reference Data When ordering drilled and tapped openings or brazed hubs for blank bodies, refer to Ordering Information pages. Gasket is designed so that it wraps around ridge top of Appleton aluminum or malleable iron device box. Result is a positive seal against moisture.

5 B-5 FS and FD Single-Gang Cast Device Boxes: Malleable Iron, Aluminum FERROUS ALLOY COPPER-FREE ALUMINUM STD. Catalogue Catalogue ILLUSTRATION SIZE PKG. Number Wt. lbs. Number Wt. lbs. 1/2 20 FS FS-1A.64 3/4 20 FS-2 Shallow 2.25 FS-2A Shallow.75 } } 1 20 FS FS-3A.64 1/2 10 FD FD-1A.90 3/4 10 FD-2 Deep 2.60 FD-2A Deep.92 } } 1 10 FD FD-3A.94 1/2 20 FSA-1 Shallow 1.70 FSA-1A Shallow.57 3/4 20 FSA-2 } 1.60 FSA-2A }.58 1/2 10 FDA-1 Deep 2.10 FDA-1A Deep.70 3/4 10 FDA-2 } 2.00 FDA-2A }.67 1/2 20 FSC FSC-1A.70 3/4 15 FSC-2 Shallow 2.40 FSC-2A Shallow.80 } } 1 15 FSC FSC-3A.70 1/2 10 FDC FDC-1A.94 3/4 10 FDC-2 Deep 2.80 FDC-2A Deep.94 } } 1 10 FDC FDC-3A /2 20 FSCC-1 Shallow 1.70 FSCC-1A Shallow.57 3/4 15 FSCC-21* } 2.20 FSCC-21A* }.74 1/2 20 FSCT FSCT-1A.84 3/4 15 FSCT-2 Shallow 2.50 FSCT-2A Shallow.84 } } 1 15 FSCT FSCT-3A.75 1/2 10 FDCT FDCT-1A /4 10 FDCT-2 Deep 2.80 FDCT-2A Deep.94 } } 1 10 FDCT FDCT-3A 1.03 } Deep } Deep 1/2 10 FDD FDD-1A.74 3/4 10 FDD FDD-2A.77 3/4 15 FSL-2 Shallow 2.34 FSL-2A Shallow.78 Dimensions on page 6, Covers on pages 7, 8 & 9. Use FD Unilets for wiring devices exceeding 1-5/8" in depth under fastening ears. Maximum copper content less than 4/10 of 1%.

6 B-6 FS and FD Single-Gang Cast Device Boxes: Malleable Iron, Aluminum FERROUS ALLOY COPPER-FREE ALUMINUM STD. Catalogue Catalogue ILLUSTRATION SIZE PKG. Number Wt. lbs. Number Wt. lbs. } Shallow } Shallow 1/2 20 FSS FSS-1A.60 3/4 20 FSS FSS-2A.60 } Shallow } Shallow 1/2 15 FST FST-1A.82 3/4 15 FST FST-2A FDT-3 Deep 3.20 FDT-3A Deep 1.07 Dimensions for FS & FD Single Gang Devices } Shallow } Shallow 1/2 15 FSX FSX-1A.91 3/4 15 FSX FSX-2A.78 1/2 10 FDX FDX-1A /4 10 FDX-2 Deep 3.00 FDX-2A Deep 1.06 } } 1 10 FDX FDX-3A 1.17 Hub A B C D E Size FS FD 1/2 3/4 5/8 1-3/ /4 1-3/8 3/4 3/4 3/4 1-3/ /4 1-3/8 1 7/8 7/8 1-1/ /4 1-3/8 Covers on pages 7, 8 & 9. Use FD Unilets for wiring devices exceeding 1-5/8 in depth under fastening ears. Maximum copper content less than 4/10 of 1%.

7 B-7 FS and FD Single-Gang Cast Device Boxes: Malleable Iron, Aluminum Catalogue Std. Wt. lbs. ILLUSTRATION Number Description PKG. Per 100 Single Gang Covers FS-4* Blank Cover, Steel Electrogalvanized FS-5* Round Receptacle Cover, Steel Electrogalvanized. Hole dia. 1-7/16" FS-6* Duplex Receptacle Cover, Steel Electrogalvanized FS-8* Round Receptacle Cover, Steel Electrogalvanized. Hole dia. 1-5/8" FS-9* Tumbler Switch Cover, Steel Electrogalvanized **FSK-ITS-G Tumbler Switch Cover, Steel Electrogalvanized **FSK-1J Steel Cover for Pilot Lamp (with Ruby Jewel ) Other colour Jewels can be furnished if specified on order: Amber, Green & Opal Single Gang Vaportight Covers FS-100g Blank Cover, Ferrous Alloy Standard Toggle Switch and Receptacle Covers Copper-Free Aluminum FS-10g Spring Door Type with 1-7/16" dia. hole in housing FS-70g Spring Door, Duplex Receptacle FS-80g Double Spring Door, Duplex Receptacle 25 FS-128 External Operation of Tumbler Switch. Push Pull Operation ON or OFF * Available in Aluminum: Add suffix A to Catalog No. ** Also for use with multiple gang Unilets with individual cover openings, page B-17. *** Cadmium Finish. Other colour jewels can be furnished if specified on orders: Amber, Green and Opal. Maximum copper content less than 4/10 of 1%.

8 B-8 FS and FD Single-Gang Cast Device Boxes: Malleable Iron, Aluminum Catalogue Number Malleable Iron Aluminum Description Ridge Top Ridge Top Cast Covers Only Weatherproof Furnished with Gasket and stainless steel screws Rocker type for square handle tumbler or toggle switches FSK-1V FSK-1V-A For duplex flush receptacle with spring cover FSK-1VDR FSK-1VDR-A Operating type for square handle tumbler or toggle switches FSK-1VS FSK-1VS-A Gasket (Replacement) Neoprene for use with cast covers above and receptacle covers on page 9 FS-GKR-1N FS-GKR-1N Cast Covers Only Furnished with stainless steel screws less gasket For standard 2 or 3 wire duplex receptacles For round flush receptacles. Hole dia. 1-7/16" For square handle toggle switches FSK-1DR-C FSK-1R-Z FSK-1TS-C For square handle toggle switches (with protecting guard) FSK-1TSG-C FSK-1TSG-CA

9 B-9 FS and FD Receptacle Covers and Plugs for Single Gang Device Boxes Weatherproof, Raintight and Dust-tight. Malleable Iron and Aluminum Covers for Ridge Top Boxes Catalogue Number Receptacles Plug Receptacle Plug Pole/Wire Malleable Iron Aluminum Ridge Top Ridge Top Receptacle Cover has threaded aluminum cap. Plug has neoprene boot and aluminum fastening ring. Furnished with receptacle, neoprene gasket, stainless Steel screws. Non-Locking, U Shaped Grounding Type Receptacle takes U shaped or round grounding contact plugs 15 Amp, 125V NEMA NEMA 5-15R 5-15P 2P, 3W FSK5-15 FSK5-15-A FSWP Amp, 125V NEMA NEMA 5-20R 5-20P 2P, 3W FSK5-20 FSK5-20-A FSWP Amp, 250V NEMA NEMA 6-15R 6-15P 2P, 3W FSK6-15 FSK6-15-A FSWP Amp, 250V NEMA NEMA 6-20R 6-20P 2P, 3W FSK6-20 FSK6-20-A FSWP6-20 Also takes FSWP5-15 Plugs Also takes FSWP6-15 Plugs Locking Grounding Type 15 Amp, 125V NEMA NEMA L5-15R L5-15P 2P, 3W FSKL5-15 FSWPL Amp, 250V NEMA NEMA L6-15R L6-15P 2P, 3W FSKL6-15 FSWPL Amp, 277V NEMA NEMA L7-15R L7-15P 2P, 3W FSKL7-15 FSWPL7-15

10 B-10 FS and FD Two-Gang Cast Device Boxes: Malleable Iron, Aluminum FERROUS ALLOY COPPER-FREE ALUMINUM STD. Catalogue Catalogue ILLUSTRATION SIZE PKG. Number Wt. lbs. Number Wt. lbs. 1/2 10 FS-12 Shallow 2.70 FS-12A Shallow.90 3/4 10 FS-22 } 2.60 FS-22A }.87 1/2 10 FD FD-12A.90 3/4 10 FD-22 Deep 2.70 FD-22A Deep FD-32 } } 2.80 FD-32A.93 1/2 10 FSC-12 Shallow 3.00 FSC-12A Shallow /4 10 FSC-22 } 3.00 FSC-22A } /2 10 FDC FDC-12A.97 3/4 10 FDC-22 Deep 3.00 FDC-22A Deep 1.00 } } 1 10 FDC FDC-32A /2 3/4 10 FSD-212* Shallow 2.70 FSD-212A* Shallow.90 *Hubs at top of illustration are 1/2 Dimensions for FS & FD Two-Gang Devices Dimensions Tandem Devices Hub A B C D E Size FS FD 1/2 3/4 5/8 1-3/ /4 2-5/16 3/4 3/4 3/4 1-3/ /4 2-5/16 1 7/8 7/8 1-1/ /4 2-5/16 Covers on page 11. Maximum copper content less than 4/10 of 1%.

11 December 2006 FS and FD Two-Gang Cast Device Boxes: Malleable Iron, Aluminum B-11 Catalogue Std. Wt. lbs. ILLUSTRATION Number Description PKG. Per 100 Two-Gang Covers FS-42* Blank Cover, Steel Electrogalvanized FS-52* Round Receptacle Cover, Steel Electrogalvanized. Hole dia. 1-7/16" FS-62* Duplex Receptacle Cover, Steel Electrogalvanized FS-92* Tumbler Switch Cover, Steel Electrogalvanized FS-69* Combination Duplex Receptacle and Tumbler Switch Cover, Steel Electrogalvanized FS-65* Combination Duplex Receptacle with Single Receptacle, Steel Electrogalvanized Vaportight Covers Furnished with gasket and stainless steel screws FS-200g* Blank Cover, Ferrous Alloy FS-1282 Aluminum Cover with Operating Mechanism for external operation of Tumbler Switches. Push Pull operation, ON or OFF Gasket (Replacement) FS-GKR-2N Neoprene - for use with 2-gang cast covers above. * Available in Aluminum: Add suffix A to Catalog No. Maximum copper content less than 4/10 of 1%. December 2006

12 B-12 FS and FD Three-Gang Cast Device Boxes: Malleable Iron, Aluminum FERROUS ALLOY COPPER-FREE ALUMINUM STD. Catalogue Catalogue ILLUSTRATION SIZE PKG. Number Wt. lbs. Number Wt. lbs. FS Three-Gang Bodies 3/4 5 FSC-23 Shallow 3.60 FSC-23A Shallow FDC-33 Deep 4.00 FDC-33A Deep 1.33 Catalogue Std. Wt. lbs. ILLUSTRATION Number Description PKG. Per 100 Three-Gang Covers FS-43* Blank Cover, Steel Electrogalvanized FS-63* Duplex Receptacle Cover, Steel Electrogalvanized FS-93* Tumbler Switch, Steel Electrogalvanized FS-699* FS-669* Combination Duplex Receptacle and Tumbler Switch Cover, Steel Electrogalvanized Combination Duplex Receptacle and Tumbler Switch Cover, Steel Electrogalvanized Vaportight Covers Furnished with gasket and stainless steel screws FS-300g* Blank Cover, Ferrous Alloy FS-1283 Aluminum Cover external operation of Tumbler Switches. Push Pull operation, ON or OFF Dimensions for Three-Gang Devices Hub A B C D E Size FS FD 1/2 3/4 5/8 1-3/ /4 2-3/16 1 7/8 7/8 1-1/ /4 2-3/16 * Available in Aluminum: Add suffix A to Catalog No. Maximum copper content less than 4/10 of 1%.

13 B-13 FS and FD Four-Gang Cast Device Boxes: Malleable Iron, Aluminum ILLUSTRATION SIZE STD. PKG. FERROUS ALLOY FS Four-Gang Bodies 3/4 3/4" 5 See FDO-4 on page B-16 Catalogue ILLUSTRATION Number Description Four-Gang Covers FS-44* Blank Cover, Steel Electrogalvanized. Fits FSC-24 FS-64* FS-94* FK-94* Duplex Receptacle Cover, Steel Electrogalvanized. Fits FSC-24 Tumbler Switch Cover, Steel Electrogalvanized. Fits FSC-24 Tumbler Switch Cover, Steel Electrogalvanized. Fits FDO-4 listed on page 16 * Above covers attach to devices Vaportight Covers Furnished with gasket and stainless steel screws FS-400G FK-400G FS-400G* Blank Cover, Ferrous Alloy. Fits FSC-24 FK-400G* Blank Cover, Ferrous Alloy. Fits FDO-4 on page 16 * Above covers attach to box Gaskets FS4-GK FK4-GK FK4-GK For Covers for FDO-4 Unilets Sponge Neoprene FS4-OGK FS4-0GK For FS-400G and FS-1284 Covers with Gasket Mounting Groove Dimensions FS and FD Unilets Hub A B C D Size FS FD 1/2 3/4 5/8 1-3/ /4 1 7/8 7/8 1-1/ /4 * Available in Aluminum: Add suffix A to Catalog No. Cast Covers are copper free (Max copper content less than 4/10 of 1%).

14 B-14 Wet Location Receptacle Covers for NEMA Configuration Receptacles Available with NEMA Configuration Receptacles or as Covers Only. Covers also accommodate Toggle Switches Applications Meet CEC receptacle requirements for wet locations: A receptacle installed outdoors where <None>exposed to weather or in other wet locations shall be in a weatherproof enclosure, the integrity of which is not affected when the receptacle is in use (attachment plug cap inserted). For industrial, commercial or residential use as a general purpose receptacle or for powering portable equipment not exceeding medium duty ratings. Mounts on FS or FD device boxes or equivalents, either single gang or multiple gang with single gang openings. Features Provides full protection in damp or wet locations per CEC. Gasketed spring door cover closes tightly automatically to protect receptacle from moisture and dirt when not in use. With plug inserted, a heavy-duty gasket in throat of receptacle seals around it to keep out moisture and dirt. Receptacle interiors comply with NEMA Standards WD-1 and WD-5. Receptacle interiors are specification grade, back and side wired. Single cover units accommodate NEMA configuration receptacles for locking or non-locking blade plugs, or toggle switches. Duplex units accommodate one receptacle and one toggle switch or any combination of the two. Covers open all the way, permitting easy plug insertion and withdrawal. Also permits adequate access to cover screws for easy attachment of cover to FS, FD or other device box. Large head cover screws are captivated. Unique design of spring door hinge provides smooth action to eliminate the possibility of bending of its stainless steel shaft. Duplex units have a separated hinge shaft for each spring door cover to reduce stress on the shafts. Spring door cover puts pressure on plug (without tilting plug) to hold plug in best position for providing optimum weatherproof seal. Stainless steel hinge springs are completely enclosed inside and out for superior resistance against corrosion. Duplex Cover on FS box. EPDM gaskets provide superior resistance to the weather, ozone and temperatures between -50 F and 260 F. Die-cast copper-free cover assemblies with 2-coat baked EPOXY finish (electrostatically applied for uniform coverage) to provide protection against corrosion. Positive ground path assured for all exposed metal parts. Receptacle interiors grounded through an extra contact in all types. Selfgrounded in Duplex units. Standard Materials Cover and face plate: die-cast copper-free (4/10 of 1% max.) aluminum. Gaskets: ethylene propylene rubber (EPDM). Cover screws and hinge shaft and spring: stainless steel. FSK-SBA Adapter: steel plate with closed cell sponged neoprene gasket. Typical application with NEMA configuration receptacle and plug, mounted on an FS box. Gasket seals around plug, keeping out moisture and dirt. Spring door closes automatically when plug is withdrawn to protect receptacle. Single Cover on FS box. Standard Finishes Cover and face plate: two-coat baked gray EPOXY finish. FSK-SBA Adapter: zinc electroplate. Compliances CSA approved. U.S. Federal Specification W-C-586B. NEC OSHA Standards, Subpart S. NEMA Standards WD-1 (straight blade) and WD-5 (locking type). Reference Data For FS/FD Boxes, see pages B5 and B6. For additional Receptacle Covers, see page B9. Spring doors open wide for easy plug insertion and cover assembly (covers shown in open position for illustration only). This view shows gaskets that protect plugs. Gasket on bottom of cover prevents entry of moisture into device box (see gasket description on page 8).

15 FS and FD Cast Device Boxes: Malleable Iron, Aluminum B-15 Wire/ NEMA Catalogue Number Amp Pole Volts Configuration With Receptacle Cover Only Non-Locking, U Shaped Grounding Type 15 2P, 3W R FSKD5-15 FSK-WRD 15 2P, 3W R FSKD6-15 FSK-WRD 20 2P, 3W R FSKD5-20 FSK-WRD 20 2P, 3W R FSKD6-20 FSK-WRD Single Cover for Non-Locking and Locking Blade Plugs, with 1-3/8" Device Opening 15 2P, 3W R FSKJ5-15 FSK-WR1 15 2P, 3W R FSKJ6-15 FSK-WR1 20 2P, 3W R FSKJ5-20 FSK-WR1 20 2P, 3W R FSKJ6-20 FSK-WR1 15 2P, 3W 125 L5-15R FSKJL5-15 FSK-WR1 15 2P, 3W 250 L6-15R FSKJL6-15 FSK-WR1 15 2P, 3W 277 L7-15R FSKJL7-15 FSK-WR1 Single Cover for Locking Blade Plugs, with 1-19/32" Device Opening Accommodates NEMA configuration receptacles with 1-19/32" opening diameter. FSK-WR2 Single Cover for GFI GFI Cover Only FSK-WGF1 Single Cover for Toggle Switches (1-19/32" Opening) Accommodates Toggle Switch. Furnished with Toggle Switch Plate to provide protection from exposed terminal wires of Toggle Switch. FSK-WT2 Adapter/Gasket For mounting Receptacle Cover on Switch Boxes (not required on FS/FD Boxes). FSK-SBA Single Duplex Receptacle Cover mounted on Switch Box with FSK-SBA Adapter/Gasket *Covers shown in open position for illustration only. Spring door closes automatically when plug is withdrawn. NOTE: All receptacle covers have an overall height of 1.16" (2.9cm).

16 B-16 FS and FD Cast Device Boxes: Malleable Iron, Aluminum Material Single Gang Two Gang Three Gang Four Gang Ferrous Alloy Aluminum FDO-1 FDO-1A FDO-2 FDO-2A FDO-3 FDO-3A FDO-4 FDO-4A Features Thick wall on all four sides. Drill and tap anywhere on sidewalls. Ground screw at top of box for easy access. Two exterior mounting lugs. Fits standard sheet metal device covers with four mounting holes. Weatherproof when used with gasketed cast weatherproof device covers. Ferrous alloy. Available in copper free aluminum: add suffix A. Standard finish Aluminum Alcote Ordering Data To determine the catalogue numbers of FDO Unilets with drilled and tapped entries, the following information should be shown: 1. Establish the Unilet catalogue number from above. 2. Determine the arrangement of entries from the illustrations in Section B, page The symbols for the conduit entry diameter are shown to the right. Where no entry is required, the symbol X should be inserted. The Unilet catalogue number, illustration number and conduit entry information should be separated by dashes. Symbols for type and size of conduit entries Brazed Hubs Brazed Hubs Drilled and Back or Drilled and Back or Size Tapped Side Wall Size Tapped Side Wall 1/2 1 A 1-1/4 4 D 3/4 2 B 1-1/2 5 E 1 3 C 2 6 F Brazed Hubs may be used on all back openings. For boxes with union hubs order with drilled and tapped openings and order any male unions listed in Section I. Example: Unilet Selected FDO-2 conduit entry arrangement #19, ( see B19 page). Drilled and tapped entries A, B, and C are to be 1/2"; D is 1 : No entry location E, and F. Catalogue number will be: FDO XX. Dimensions

17 FS and FD Cast Device Boxes: Malleable Iron, Aluminum B-17 Catalogue Std. Wt. lbs. ILLUSTRATION Number Description PKG. Per 100 FD Unilets with Lugs Take Single-Gang Covers listed on page B3 and B8. FD depth 2-19/32" FD-1L Single-Gang FD-2L Two-Gang FD-3L Three-Gang FD-4L Four-Gang Dimensions of FD Unilets with Lugs 2-13/16 6-1/2 10-3/ /8 4-9/16 3-1/4 7/8 5-9/16 6-5/ /32 Dia. 5-3/ THRD. 9-7/ /8 Cadmium Finish. Maximum Hub Size 1-1/2" threaded, and 1-1/4" no-thread or union.

18 B-18 FS and FD Cast Device Boxes: Malleable Iron, Aluminum Hub Information Listed below are the various types of brazed hubs which may be used with the FD Unilets listed on page 17 and the FDO box listed on page 16. Threaded, no-thread and union hubs may be brazed at any desired location, and the illustrations showing typical hub arrangements are on page 19. The illustrations show a maximum of five hubs on any one side of a Unilet, but it is possible to place more than five hubs on the top and bottom of three and four-gang Unilets. Look at the chart below for the maximum hub diameter and the minimum hub spacing distance. This chart, together with the Unilet dimensions shown on pages 16 and 17 will enable you to figure the maximum number of hubs which may be used. The hubs will be symmetrically placed about the axis of the Unilets unless exact dimensions are specified on the order. Threaded No-thread No-thread For For For Electrical Size Rigid Conduit Rigid Conduit Metallic Tubing Union Maximum Hub Size Maximum Hub Diameter Maximum Distance Between Conduit Centres FS 1 3/4 3/4 3/4 FD 1-1/2 1-1/4 1-1/4 1-1/4 1/2 1-1/8 1-1/2 1-1/8 1-1/2 3/4 1-3/8 1-25/32 1-3/8 1-25/ /16 2-1/32 1-9/16 2-1/32 1-1/4 1-15/ / / /32 1-1/2 2-3/16 1/2 1-1/4 1-9/16 1-1/4 1-9/16 3/4 1-1/2 1-27/32 1-1/2 1-27/ /4 2-3/32 1-3/4 2-3/32 1-1/4 2-1/8 2-29/32 2-1/8 2-29/32 1-1/2 2-3/8 Order Information example: Unilet Selected FD-2L conduit entry arrangement #19, ( see page 17). Drilled and tapped entries A, B, and C are to be 1/2"; D is 1": No entry location E, and F. Catalogue number will be: FD-2L XX.

19 FS and FD Cast Device Boxes: Malleable Iron, Aluminum B-19 Ordering Data To determine the catalogue numbers of Unilets with drilled and tapped entries or hubs, the following information should be shown: 1. Unilet catalogue number from listings on page 16 or Sketch number of entry arrangement selected from illustrations below. 3. Entry symbols taken from the table shown on the bottom of this page. Start from the left on the top of the Unilet and continue in rotation clockwise around its body. Where no entry is required, the symbol X should be inserted. The three various divisions of the catalogue number should be separated by dashes. Ordering example: The Unilet selected is an FDO4 and the entry arrangement is sketch number 12. Entry A, B and C are to be 1/2" drilled and tapped for rigid conduit; D is to be a 1" hub and there is no entry at location E. The catalogue number will be as follows FDO CX. Single, Two, Three and Four-Gang (Front View and oriented as mounted) A TOP A A B A B C A B C D A B C D E B SIDES A B C C C E F G BOTTOM B D E F A A A B A B A B C A B C D A B C D E D B C B D C E D F E G F C C A A A A B A B A B C A B C B C H C B B F C H D C D G J D C E D F E F E D G F E A B C A B C D A B C D A B C D A B C D E A B C D E A B C D E K J D E M K E E M F L F O N F G H G F F E J H G F K J H G G F Symbols for type and size of conduit entries Brazed Hubs Brazed Hubs Drilled and Back or Drilled and Back or Size Tapped Side Wall Size Tapped Side Wall 1/2 1 A 1-1/4 4 D 3/4 2 B 1-1/2 5 E 1 3 C 2 6 F L K J H G M L K J H

20 B-20 FSH and FAH Weatherproof Receptacle and Breaker Assemblies For use with Rigid Conduit FSH and FAH Series Assemblies are used outdoors to supply power in remote areas such as: Garden Lighting Parking Lots Marinas Campsites Trailer Parks These units will accomodate devices and covers normally used on single gang FS and FD unilets. Catalogue Std. ILLUSTRATION Number Description PKG. Threaded 2" Mounting Hub FAHD-16** Double Face Fitting Only 2 Recommended mounting height 2 6 Featured 40 angle face uses standard covers FAHD-1611** FAHD-1612** FAHD-1613** Complete with Two Duplex Receptacles and Covers 2 Complete with One Duplex Receptacle and One Duplex Circuit Breaker for two 125V Circuits 2 Complete with One Duplex Receptacle and One 1-Pole 15 Amp Circuit Breaker 2 Aluminum* can be supplied on request: Add suffix A to Catalog No. *Copper free less than 4/10 of 1%. **Epoxy Coated

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction. S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated

More information

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC Applications To provide access to large and heavy conductors for pulling, splicing, maintenance and future changes / upgrades Allows connection of straight conduit runs, branch conduit runs and 90 bends.

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

Red Dot. Rigid Fittings. Table of Contents

Red Dot. Rigid Fittings. Table of Contents Table of Contents Conduit Unions Hazardous Locations... C2 C3 Conduit Fittings Hazardous Locations... C4 C5 Sealing Fittings Hazardous Locations... C6 C7 Conduit Hubs Raintight for Threaded Rigid Conduits...

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy. Material, Color, and Finish Color Gray 0 ELECTROSTATICALLY PAINTED BAKED POWDER COATED

S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy. Material, Color, and Finish Color Gray 0 ELECTROSTATICALLY PAINTED BAKED POWDER COATED 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy Catalog Number Manufacturer Description Weight per unit Product Category

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533-RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section includes conduit raceways, and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating 3 LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. eatures Intermateability UL Listed and CSA Certified interchangeability

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

PRODUCT CATALOG & BUYER S GUIDE

PRODUCT CATALOG & BUYER S GUIDE PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! Table of Contents Table of Contents Introduction Performance Matters!...4-15 Corrosion Protection...16 Conduit PVC

More information

PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN!

PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! Table of Contents Table of Contents Introduction Performance Matters!...4-15 Corrosion Protection...16 Conduit PVC

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 26 05 33 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes conduit and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and handholes.

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Receptacles,

More information

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry Expansion & Deflection Fittings SOLUTIONS for the Construction Industry TTINGS FI ST D LO C AF/AF8 SERIES e st d, in M a c h e d, As d in D e s i g n e d, b le the Casted Body with NPT hub size se m Ca

More information

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY SECTION 280528 - PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Metal conduits, tubing, and fittings. 2. Nonmetallic conduits, tubing, and fittings. 3.

More information

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit

More information

Flush Service Floor Boxes

Flush Service Floor Boxes Flush Service Floor Boxes PRODUCT SPECIFICATION: Flush Service Floor Boxes PART 1: Overview Considerations when writing specifications: Floor boxes are manufactured in various sizes, configurations and

More information

SECTION ELECTRICAL MATERIALS AND METHODS

SECTION ELECTRICAL MATERIALS AND METHODS SECTION 26 00 20 ELECTRICAL MATERIALS AND METHODS PART 1: GENERAL 1.01 WORK INCLUDED A. Furnish and install all conduit, conduit fittings and boxes to complete the installation of all electrically operated

More information

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit can

More information

ALUMINUM OR IRON CONDUIT BODIES

ALUMINUM OR IRON CONDUIT BODIES 7 SERIES ALUMINUM OR CONDUIT BODIES LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Features Intermateability UL Listed

More information

Unflanged Junction or Pull Boxes

Unflanged Junction or Pull Boxes UA12 Unflanged Junction or Pull Boxes Cast Iron Box For Surface Mounting - NEMA 4 Type YS Raintight - Watertight - Dust Tight UA12 Use: These boxes are general purpose enclosures listed by Underwriters

More information

OVERHEAD SERVICES - SECONDARY

OVERHEAD SERVICES - SECONDARY OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...

More information

8461C 4SQ, 1"RSD Rndopnw/Ers CVR

8461C 4SQ, 1RSD Rndopnw/Ers CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SQ, 1"RSD Rndopnw/Ers CVR Appleton/Oz Gedney Catalog Number Manufacturer Appleton/Oz Gedney Description Steel Square

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

Procurement Services SVC East Fowler Avenue Tampa, Florida (813) Procurement Services SVC 1073 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: https://www.usf.edu/business-finance/purchasing/public-bids/rfi.aspx October 12, 2018 Invitation to

More information

L-2 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit.

L-2 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. -2 Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. Applications ocations where receptacles are used with stationary or portable electrically operated devices such as lighting

More information

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SD1 4S Box 1"Ko 2-1/8DP Appleton/Oz Gedney Catalog Number 4SD1 Manufacturer Appleton/Oz Gedney Description Steel Square

More information

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used. SECTION 16110 RACEWAYS AND FITTINGS 1.00 RACEWAYS: All wiring shall be in raceways. Raceways shall be run in slabs, walls, above ceilings or exposed as indicated on drawings. Acceptable raceway and their

More information

Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market

Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market Intermatic.com Our durable lineup of die-cast, low-profile and plastic weatherproof covers offers rugged protection

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

SECTION CONDUITS AND BOXES

SECTION CONDUITS AND BOXES PART 1 GENERAL 1.01 DESCRIPTION A. Work covered by this section includes the furnishing and installation of conduits and boxes and the testing of the completed electrical systems 1.02 SUBMITTALS A. The

More information

SECTION RACEWAYS

SECTION RACEWAYS SECTION 16110 RACEWAYS PART 1 GENERAL 1.1 SYSTEM DESCRIPTION A. Provide a complete raceway system suitable for receiving wire and cable and continuous from outlet to outlet. System shall be complete with

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

a) Line and load compartments must be separated by a stable barrier.

a) Line and load compartments must be separated by a stable barrier. 1.00 GENERAL 1.01 The electric utility shall furnish and connect all meters, instrument transformers, test switches, and meter control wiring necessary to complete the meter installation. 1.02 The customer

More information

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein.

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein. 16470 PANELBOARDS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 16 An optional keynote to

More information

SPECIAL SPECIFICATION 1276 Pedestrain Overpass Lighting

SPECIAL SPECIFICATION 1276 Pedestrain Overpass Lighting 1993 Specifications CSJ 0074-06-199 SPECIAL SPECIFICATION 1276 Pedestrain Overpass Lighting 1. Description. This Item shall govern for furnishing and installing the various types of lighting fixtures,

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated.

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated. SECTION 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 -GENERAL 1.1 SUMMARY A. Section includes conduit and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and handholes.

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved PART 1 GENERAL 1.01 DESCRIPTION A. Provide all raceways, fittings, and boxes of specified type required for complete project. Install all systems in raceways unless specifically noted otherwise. Provide

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

VPL-3300B Commercial Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3300B Commercial Vertical Platform Lift Technical Specifications MODEL NUMBERS: Unenclosed VPL-3300B Series: Models VPL-3353B and VPL-3375B (DC-powered) 3-Gate VPL-3300B Series: Models

More information

Raceway and Boxes for Electrical Systems Page 1 of 7

Raceway and Boxes for Electrical Systems Page 1 of 7 Last Update: May 12, 2017 A. Conduits: Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which shall have stubs to

More information

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Knockout Location Knockout Size 4SSPLDR

More information

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS DAIMLERCHRYSLER MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS ISSUE DATE: 5/1/90 EFFECTIVE DATE: 2/4/92 REVIEW DATE:

More information

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches).

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches). H. The National Electric Code 2011 is hereby revised: 1. Article 230.70 (A) (1) Delete in its entirety and insert: 230.70 (A) (1) Readily Accessible Location. The service disconnect means shall be installed

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Greenbook Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 08-15-17 Rev. #06:

More information

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1 INDEX Page SECTION 1.0: SCOPE 1 1.1 Toronto Hydro Requirements 1 1.2 Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1 SECTION 3.0: DEFINITIONS AND THE INTERNATIONAL SYSTEM OF UNITS 1 3.1 Definitions

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal conduit B. Flexible metal conduit C. Liquid tight flexible metal conduit D. Electrical metallic tubing E. Non-metallic conduit F. Fittings and conduit bodies

More information

Introduction to Cast Junction Boxes

Introduction to Cast Junction Boxes UA2 Introduction to UA2 I Purpose of Enclosure Enclosures are used to protect personnel against accidental contact with enclosed electrical devices or connections and to protect the enclosed devices or

More information

A. American Society for Testing and Materials (ASTM): Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.

A. American Society for Testing and Materials (ASTM): Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft. SECTION 260000 ELECTRICAL PART 1- GENERAL 2.1 SUMMARY : Provide complete distribution systems for electrical power as shown on the drawings or required by other sections of these specifications. A. Work

More information

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, cabinets, and track busway for electrical wiring.

More information

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

SECTION PARK NON-SEGREGATED BUS SPECIFICATION Page 1 of 5 SECTION ------- PARK NON-SEGREGATED BUS SPECIFICATION 1.0 SCOPE 1.1. This specification describes assemblies of 600V, 5Kv and 15Kv non-segregated bus duct, which will be installed indoors and

More information

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System The Raceway Solutions System is an in-slab wire management product for delivering power, voice and data services

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section AUTOMATIC CONTROL VALVE INSULATED ENCLOSURE (HOT BOX)

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section AUTOMATIC CONTROL VALVE INSULATED ENCLOSURE (HOT BOX) Section 15959 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and the installation of Automatic Control Valve Insulated Enclosures (Hot Boxes) for control valves installed on water lines

More information

OPERATING PROCEDURE NO. 310

OPERATING PROCEDURE NO. 310 OPERATING PROCEDURE NO. 310 Related Operating Procedures: 310A; 310B; 310C; 310D SUBJECT: Conditions of Service Issued: February 10, 2014 Revised: March 28, 2016 OBJECTIVE: To establish the rules, regulations

More information

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC). SECTION 16111 CONDUITS PART 1 - GENERAL 1.01 DESCRIPTION A. General: Provide conduits, complete, as shown, specified or required per Contract Documents. Principal items include: 1. Rigid aluminum conduit.

More information

Section BUILDINGS, SHELTERS, ENCLOSURES

Section BUILDINGS, SHELTERS, ENCLOSURES Section 13121 BUILDINGS, SHELTERS, ENCLOSURES Part 1 GENERAL 1.1 SECTION INCLUDES 1.2 A. Pre-engineered buildings. B. Pre-engineered shelters. C. Pre-engineered enclosures. D. Electrical wiring and devices

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES OFFSET TYPE N.J. Specification No. Effective Date: July 1, 2001 New

More information

Project: Type: Qty: Optics. Series. Reflector Mounting Lamping Finish Voltage Options BLC - S BLC-L 21 1 /4" 36 1 /4" 3 1 /2" O.D.

Project: Type: Qty: Optics. Series. Reflector Mounting Lamping Finish Voltage Options BLC - S BLC-L 21 1 /4 36 1 /4 3 1 /2 O.D. Project: Type: Qty: Series Optics Mounting Lamping Finish Voltage Options Pole Series Finish Pole Options Series Optics Mounting Lamping Finish Voltage Options BLC Beta Lantern L S Flat Glass Lens Sagged

More information

SERIES VAP EXAMPLE: VAPRC2CL26TTTBKMV WATT CAT# APPLICATIONS FEATURES & BENEFITS SPECIFICATIONS ORDERING DATA

SERIES VAP EXAMPLE: VAPRC2CL26TTTBKMV WATT   CAT# APPLICATIONS FEATURES & BENEFITS SPECIFICATIONS ORDERING DATA APPLICATIONS The Mobern VAP Series of architectural lighting in applications to provide a luminaire which is aesthetically attractive and offers a vandal resistant performance. These applications include;

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree

More information

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION SECTION 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 - GENERAL 1.1 SUMMARY A. This section supplements all sections in this division, including pipe, fittings, valves, and connections for sprinkler

More information

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 23 81 00 DECENTRALIZED HVAC EQUIPMENT A. The other Contract Documents complement the requirements of this section. The General requirements apply to the work

More information

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 612 SEPTEMBER 1984 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES 612.01 SCOPE 612.02 REFERENCES 612.03 Not Used 612.04 Not Used

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

Switch Rack Assemblies

Switch Rack Assemblies Switch Rack Assemblies Applications: Free-standing switch rack assemblies are used: To provide a complete motor control center in one integrated package Outdoors and indoors In damp, wet or corrosive locations

More information

Youngstown State University

Youngstown State University SECTION 260533 - RACEWAYS PART 1 - GENERAL SUMMARY A. This section includes raceways for electrical wiring. Types of raceways in this section include the following: 1. Flexible metal conduit 2. Liquid

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

SECTION RACEWAYS AND BOXES

SECTION RACEWAYS AND BOXES SECTION 16110 RACEWAYS AND BOXES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 2476 JANUARY 1990 MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT 2476.01 SCOPE 2476.02 REFERENCES 2476.05 MATERIALS TABLE OF CONTENTS

More information

Project No: Pakenham Branch Library, Pakenham, Ontario Section

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 5 1 GENERAL 1.01 RELATED SECTIONS.1 Section 01 33 00 - Submittal Procedures..2 Section 01 78 00 - Closeout Submittals. 1.02 REFERENCES.1 American Society for Testing and Materials

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

TUFF-SEAL RSF SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSF Series Aluminum Flat Cable Cord Grips G 16

TUFF-SEAL RSF SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSF Series Aluminum Flat Cable Cord Grips G 16 TUFF-SEAL RSF SERIES ALUMINUM CORD RIPS RSF Series Aluminum Flat Cable Cord rips Tuff Seal RSF Cord rips are specially designed for heavy-duty, flat cable or festoon system applications. Unique to the

More information

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES O SERIES / 5 SERIES ALUMINUM OR MALLEABLE CONDUIT BODIES Suitable for wet locations when used with gasketed Federal Specification W-C-586D/A-A 50563. Suitable for use in hazardous location applications

More information

IRON CONDUIT BODIES 5-5/16 (135) 6-9/16 (167) 7-9/16 (192) 8-7/16 (214) 10-3/8 (264) 12-3/8 (314) 15-5/8 (397) 15-5/8 (397)

IRON CONDUIT BODIES 5-5/16 (135) 6-9/16 (167) 7-9/16 (192) 8-7/16 (214) 10-3/8 (264) 12-3/8 (314) 15-5/8 (397) 15-5/8 (397) KILLARK C Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Features Completely interchangeable with competative bodies, gaskets,

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump Pump Specifications 450 Series 1/2 hp Submersible Sump Pump 450_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 450-Series Dimensional

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE

More information

Liquidtight Flexible Metal Conduit Fittings For Control and Power Cable Applications. * U.L. and CSA not applicable.

Liquidtight Flexible Metal Conduit Fittings For Control and Power Cable Applications. * U.L. and CSA not applicable. For Control and Power Cable Applications Hub Conduit Dimensions (in.) Cat. No. Size Size A B C 5229* 1/4 1/4 27/32 1-3/8 15/32 5330* 3/8 5/16 63/64 1-3/8 15/32 * U.L. and CSA not applicable. Steel, malleable

More information

SECTION FIELD PANELS

SECTION FIELD PANELS Stanford University Facilities Design Guidelines SECTION 25 14 23 FIELD PANELS PART 1 - GENERAL 1.1 SUMMARY A. This section includes control panel and enclosure requirements for building control systems.

More information

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products. Grounding BURNDY Products E-44 TYPE GRC HIGH STRENGTH GROUND ROD CLAMP For Copper Cable to Rod High copper alloy ground connector for joining a range of cable to copper clad, galvanized steel, and stainless

More information

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building 2004 Specifications CSJ 0720-03-095 SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building 1. Description. Furnish and install Environmentally Controlled Communications Building

More information

ELECTRICAL SECTION 2

ELECTRICAL SECTION 2 ELECTRICAL SECTION 2 COMMON WORK RESULTS FOR ELECTRICAL PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. This Section includes raceways, conductors and cables, grounding materials, boxes, electrical identification

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

1993 Specifications CSJ SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets

1993 Specifications CSJ SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets 1993 Specifications CSJ 0331-04-050 SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets 1. Description. This Item shall govern for furnishing and installation of Equipment Cabinets for the Bridge Collapse

More information

Customer Owned Meter Enclosures for Self-Contained Watthour Meters

Customer Owned Meter Enclosures for Self-Contained Watthour Meters Revision No. 4 Page 1 of 15 SPECIFICATION Page 2 of 15 RECORD OF SPECIFICATION APPROVALS: This Specification is approved for the inclusion of subject products on the Florida Meter Group s Approved Metering

More information