Fascia Systems S. Old Peachtree Rd Norcross, GA (800) Copyright 2010, Innovative Metals Company, Inc.

Size: px
Start display at page:

Download "Fascia Systems S. Old Peachtree Rd Norcross, GA (800) Copyright 2010, Innovative Metals Company, Inc."

Transcription

1 Fascia and Coping Systems 4648 S. Old Peachtree Rd Norcross, GA (800) Copyright 2010, Innovative Metals Company, Inc.

2 Any Building In Any Place At Any Time Could Be Called Upon to Protect the Contents Within The turn of the century brought a rash of severe weather events and the promise of a dynamic climate that will continue to produce these natural assaults. Experts around the world agree that we are at the precipice of an extreme weather era. Whether due to global warming or simply following cyclical trends, it seems clear that the frequency and severity of high-velocity wind events will continue to place demands on our structural environment. Some of the more notorious storms of the decade precipitated intensive study of the vulnerability of roofing systems by organizations such as the Roofing Industry Committee on Weather Issues (RICOWI) and Factory Mutual Global (FM). These studies revealed that the vast majority of all weather-related losses (75%) were due to roof failures, and of those, more than half were due to perimeter failure. As a result, building codes and standards have evolved to demand better design and performance of roofing systems. The 2003 and subsequent editions of the International Building Code (IBC) contain provisions requiring edge-metal flashings (copings, fascia, gravel stop) to be designed and installed in accordance with ANSI/ SPRI ES-1, Wind Design Standard for Edge Systems Used with Low Slope Roof Systems Edge securement for low-slope roofs. Low-slope membrane roof system metal edge securement, except gutters, shall be designed and installed for wind loads in accordance with Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1, except the basic wind speed shall be determined from Figure Although these studies and the adoption of the ES-1 standard by IBC are most directly attributable to the destruction inflicted by hurricanes, events such as straight-line winds and tornadic activity associated with common seasonal storms inflict widespread damage each year. FEMA has divided the United States into four zones that reflect the number and strength of extreme windstorms encountered in each region. The tables to the right clearly illustrate that no area is immune to wind-related roofing damage. R Copyright 2010, Innovative

3 That s Why We Bring You PerformaEdge A line of performance-inspired Edge Systems from IMETCO ES-1 Certification Edge Systems from IMETCO have successfully passed the three tests required by the ANSI/SPRI ES-1 standard: 1. RE-1: Roof Edge Termination Test The RE-1 test evaluates the perimeter attachment to a minimum holding power of 100 pounds per foot. The membrane is pulled at a 45-degree angle to the roof deck to simulate a billowing. Failure occurs when the membrane detaches from the edge termination, or the termination detaches from its mounting. 2. RE-2: Pull-off Test for Metal Edge Flashing RE-2 evaluates the strength of the metal edge flashing to ensure that the fascia system meets or exceeds the building s calculated design wind pressure. An incremental load is applied to the face of the specimen and held for 60 seconds, then removed and increased in increments of 25 psf until 150 psf, then increments of 10 psf are applied thereafter. The results must meet or exceed the calculated design pressure of the building. Failure occurs with securement loss of any component of the roof edge, or deformation that would hinder weather protection at the edge. 3. RE-3: Pull-off Test for Metal Wall Coping RE-3 evaluates the strength of a metal coping cap to ensure that it meets or exceeds the building s calculated design wind pressure. Incremental loads are applied as with the RE-2 test, where the load is applied to the face and top simultaneously. Failure occurs with the securement loss of any component of the roof edge system, or deformation that would hinder weather protection at the edge. 3 Metals Company, Inc. (800)

4 ES-FX Series Fascia IMETCO s line of Edge Systems includes our strongest and most versatile fascia, the ES-FX. This extruded aluminum fascia is compatible with most of the roof systems marketed today. From multi-ply built-up roofs to single ply systems to thicker modified bituminous membranes, the ES-FX fascia system can easily adjust to each one. Face dimensions of the ES-FX fascia system provide coverage for up to three nailers. Engineered with its VariTight TM flashing component, ES-FX allows for installation with various roof membrane types and thicknesses without any penetration of the membrane. The VariTight TM screws supplied with the system allow for removal and replacement of the fascia cover in retrofit applications, helping to reduce costs and to expedite project completion. The consistent and crisp lines of the extruded cover cannot be matched by a formed product. 1" 2 1/2" SPECIFY 1 3/4" ES-FX Fascia FASCIA COVER x 10'-0" 6" CONCEALED SPLICE EACH JOINT 18"o.c. (by IMETCO) VARI-TIGHT FLASHING (by IMETCO) CANT DAM x 10'-0" MEMBRANE FLASHING (by OTHERS) 1 1/4" ROOFING 12" o.c. MAX. (by OTHERS) 1 1/4" ROOFING 18" o.c. MAX. (by OTHERS) ANSI/SPRI ES-1 approved Tested face dimensions up to 10 inches Engineered 3-piece design allows various roof membrane thicknesses 20-year Blow-Off / Leak-Tight warranty available 20-year finish warranty available 10-foot standard length 22-gauge galvanized steel cant dam Fascia fasteners included Concealed 6-inch splice plate Heavy gauge extruded aluminum cover Post-coated Kynar standard and custom colors Mill finish available Corners & accessories mitered and welded in factory Does not penetrate roof membrane Fully welded radii available Product: ES-FX600 ES-FX700 ES-FX775 ES-FX850 ES-FX925 ES-FX1000 Face Size: 6.0 inches 7.0 inches 7.75 inches 8.5 inches 9.25 inches 10.0 inches R Copyright 2010, Innovative

5 ES-F Series Fascia The old-school gravel stop and fascia of the past is no longer acceptable for most roof systems of today. Fascia systems must be tested and approved to meet the ANSI/SPRI ES-1 standard as required by the IBC. Once again, with its line of fully tested Edge Systems, IMETCO demonstrates its commitment to our customers by providing a full line of performance-inspired fascia and coping for use with built-up, single ply, and modified roofing systems. SPECIFY 1/2" 1 1/2" ES-F Fascia FASCIA COVER x 10'-0" FASCIA CANT x 10'-0" 6" CONCEALED SPLICE EACH JOINT MEMBRANE FLASHING (by OTHERS) 1 1/4" ROOFING 12" o.c. MAX. (by OTHERS) Features and Benefits: ANSI/SPRI ES-1 approved Tested face dimensions up to 9½ inches Two-piece design 10-foot standard lengths (other lengths available) 22-gauge galvanized steel cant dams Concealed 6-inch splice plate Factory fabricated corners and accessories Does not penetrate the roof membrane No exposed fasteners Installs securely with various membrane thicknesses 20-Year Blow-Off/Leak-Tight Warranty available 20-Year Finish Warranty available Materials and Coatings.040,.050 &.063 aluminum 24- and 22-gauge galvanized steel 24- and 22-gauge stainless steel Pre-finished Kynar coated aluminum & steel standard Post-coated Kynar custom colors available 1 3/4" 1/2" Product: ES-F500 ES-F650 ES-F800 ES-F /4" ROOFING 12" o.c. MAX. (by OTHERS) Face Size: 5.0 inches 6.5 inches 8.0 inches 9.5 inches Metals Company, Inc. 5 (800)

6 ES-C Series Coping Edge Systems from IMETCO are engineered for performance. A leader in highly engineered structural standing seam metal roofing, IMETCO understands the need for tested and secure metal Edge Systems. IMETCO tests our coping system based on the real-life ANSI/SPRI ES-1 method to meet or exceed your specific project requirements. That s why our ES-C Series Coping system is one of the strongest in the industry. Features and Benefits: ANSI/SPRI ES-1 approved Tested wall widths up to 24 inches Tested face dimension up to 6 inches Snap on design 10-foot standard lengths (other lengths available) Install on wood nailers, masonry or steel parapet walls Heavy-gauge galvanized steel anchor plates (5 o.c. standard placement) Anchor plate fasteners included Concealed 6-inch splice plate with butyl sealant tape Mitered & fully welded corners, end caps, transitions, etc. Single slope and peaked profiles Fully welded radii 20-Year Blow-Off/Leak-Tight Warranty available 20-Year Finish Warranty available Materials and Coatings.040,.050,.063,.080 &.125 aluminum 24- and 22-gauge galvanized steel 24- and 22-gauge stainless steel Pre-finished Kynar coated aluminum and steel standard Post-coated Kynar custom colors available "B" "B" 1 3/8" 1 3/4" 1/8" ES-C Sloped Coping COPING COVER x 10'-0" 6" CONCEALED SPLICE EACH JOINT ANCHOR 5'-0" o.c. "A" (ACTUAL WALL WIDTH) ES-C Peaked Coping "A" (ACTUAL WALL WIDTH) COPING COVER x 10'-0" (4) FASTENERS PER ANCHOR PLATE 3/4" 1/4" 6" CONCEALED SPLICE EACH JOINT ANCHOR 5'-0" o.c. (4) FASTENERS PER ANCHOR PLATE "C" CLEARANCE FOR WALL VARIATIONS 5/8" 3/4" "C" 1/8" CLEARANCE FOR WALL VARIATIONS R Copyright 2010, Innovative

7 EZ Edge Formed Line EZ Edge Sloped and Peaked Coping 5/8" 5/8" 5/8" IMETCO s EZ Edge line combines quality with economy. These products offer proven reliability and pleasing aesthetics at a lower cost than performance-inspired edge systems. For use with built-up, single-ply and modified roofing systems, all of the EZ Edge products are available with a 20- year Kynar finish warranty. EZ-Edge fascia and coping is available with a weather-tight warranty up to 10 years. "B" "C" "B" "A" "A" (ACTUAL WALL WIDTH) 7/8" EZ Edge Formed Fascias and Extender 7/8" "C" Features and Benefits: Factory fabricated and field proven Standard & project-specific profiles & sizes Simple, strong design 10-foot standard lengths (other lengths available) Concealed 6-inch splice plates Factory-made corners, end caps, etc. Mitered and fully welded corners, end caps, transitions, etc. available Welded radius coping, fascia & gutter 20-Year Finish Warranty available 4" 4" SPECIFY 1 1/2" EQUAL 1 1/2" EQUAL 1 1/2" EZ Edge A and D Style Gutter, and Downspout Materials and Coatings.032,.040,.050,.063,.080 &.125 aluminum 24- and 22-gauge galvanized steel 24-gauge stainless steel Pre-finished Kynar coated aluminum and steel standard Post-painted Kynar custom colors available 1" 1" 1" 1" 1" 1" 2" 1" 7 Metals Company, Inc. (800)

8 IMETCO s 28 standard, designer and premium colors are all cool colors, with SR measurements of.25 or better. Custom colors and specialty finishes are also available. Ask your IMETCO representative for more information. Standard Collection Irish Mist Almond Suede Emerald Forest Blue Sapphire Tuscan Slate Epic Bronze Solar White Cadet Gray Sandstone Chestnut Georgian Brick Opal Star Colonial Red Silver Cloud Wedgewood Weathered Copper Designer Collection Iron Mountain Cardinal Red Carolina Coast Natural Patina Caribbean Coral Merlot The Total Solution IMETCO offers a full line of metal roofing, wall, and edge systems and accessories. Be sure to ask your representative for information about other products and solutions from IMETCO, such as: Series 300 Standing Seam Metal Roofing System Precision engineering for long-term weather-tight performance Rigorously tested to be leakproof and to withstand hurricane-force winds Ideal for structural or architectural applications One-piece clip facilitates unlimited thermal movement 2⅜-inch high symmetrical seam with a separate, easy-to-install seam cap Factory-applied hot-melt sealant that remains isolated from the clip Can be curved or tapered Total Metal Roof & Deck System Premium Collection Platinum Silver Roman Copper Brite Copper Champagne Preweathered Galvalume Galaxy Blue Signature Collection* Antiqu Bronze Artisan Steel IMETCO Series 300 standing seam metal roofing Martin Fireproofing Perform-A-Deck metal roof deck system Tested to resist extreme winds and impact from wind-born debris, as recommended by FEMA 361: Design and Construction Guidance for Community Safe Rooms Single source warranty covers complete assembly Prestige Collection* AquaBlock Underlayment Acrylic Galvalume United Zinc: Glacier Gray United Zinc: Onyx Black TextureMatte Stainless Steel Copper Copper Patina Field Stone Quartz The colors above are for reference only. To select your final color, please request a metal color sample. Heat tolerant (250+ f) Engineered for metal and tile roofing Self-adhering, self-sealing 100% SBS-modified 90-day exposure resistance The IMETCO Advantage For more than a decade, we at IMETCO have enjoyed our reputation as a manufacturer committed to providing products of only the highest quality. Our staff comprises expertise in metal roofing, design, engineering, testing, code compliance, manufacturing, and more. Above all, our staff excels in providing unparalleled customer service. At IMETCO, your satisfaction is our only measure of success! * Signature and Prestige Collections are available for select products. Special conditions may apply. Contact your IMETCO representative for more information. Galvalume is steel pre-treatment and a registered trademark of Biec International Inc. Hylar is a fluorocarbon paint finish available on our metal products, and is a registered trademark of Ausimont USA Inc. Kynar is a fluorocarbon paint finish available on our metal products, and is a registered trademark of Elf Atochem North America Inc. FM (Factory Mutual) is a world leader in property loss prevention and control engineering, research, and training. Its research-based recommendations set new standards that reduce the chance of property loss due to fire, weather conditions, and failure of electrical or mechanical equipment. It is a registered trademark of Factory Mutual Global, and must be identified as such whenever referred to in print. Series 300 and all other trademarks are owned by Innovative Metals Company, Inc. (IMETCO) S. Old Peachtree Rd Norcross, GA (p) s (f)

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

4648 S. Old Peachtree Rd. Norcross, GA (p) (f)

4648 S. Old Peachtree Rd. Norcross, GA (p) (f) 4648 S. Old Peachtree Rd. Norcross, GA 30071 800.646.3826 (p) 770.908.2264 (f) 1 R0311 The Test of Time Timeless elegance, proven performance, strength and versatility make Series 300 the metal roofing

More information

TremLock TM. Coping. A Pre-engineered Metal Coping System. oofing

TremLock TM. Coping. A Pre-engineered Metal Coping System. oofing oofing 7.3 A Pre-engineered Metal System oofing A Pre-engineered Metal System TremLock is a pre-engineered metal coping system designed with no exposed fasteners to accommodate movement. Basic Use: TremLock

More information

GARLAND METAL SOLUTIONS. Honest Performance... Trusted Protection

GARLAND METAL SOLUTIONS. Honest Performance... Trusted Protection GARLAND METAL SOLUTIONS Honest Performance... Trusted Protection COMPLEMENTING YOUR DESIGNS BEAUTIFULLY Intelligently designed and inherently beautiful, Garland s premium metal solutions provide honest

More information

Fascia Systems. oofing 7.1

Fascia Systems. oofing 7.1 Systems oofing 7.1 TremLock TM A Pre-engineered, Non-Penetrating Metal Edge System oofing TremLock TM Pre-engineered, Non-penetrating Metal Edge System The TremLock is a pre-engineered, non-penetrating

More information

Malarkey s well-designed, competitively-priced Endura products can assist with completing projects ON TIME AND ON BUDGET.

Malarkey s well-designed, competitively-priced Endura products can assist with completing projects ON TIME AND ON BUDGET. Malarkey s well-designed, competitively-priced Endura products can assist with completing projects ON TIME AND ON BUDGET. Ridge Vent Multi-Ply or Modified Vented Fascia Raised Profile RP Tapered Version

More information

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations. ms1505 SECTION 07 60 00 - Page 1 PART 1 GENERAL 1.01 SECTION INCLUDES A. Coping flashing and cleats. B. Counterflashings at roof edge. C. Counterflashings at roof-mounted mechanical equipment, vent stacks,

More information

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920 SECTION 07620 - FLASHING AND SHEET METAL PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: Provide all flashing and sheet metal not specifically described in other Sections of these Specifications but

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

Sheet Metal Flashing and Trim

Sheet Metal Flashing and Trim University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 076200 - Sheet

More information

Counterflashing. oofing 7.2

Counterflashing. oofing 7.2 oofing 7.2 TremLock TM Surface Mounted A Pre-engineered Metal oofing TremLock TM Surface Mounted A Pre-engineered Metal The TremLock Surface Mounted, designed to work with all types of flashing membranes,

More information

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES March 26, 2017 Page 1 DESCRIPTION PRODUCT FEATURES Factory fabricated metal wall or soffit cladding with related flashings and accessory components. Online brochure available at: http://www.lenmak.com.

More information

Town of Gordonsville, Virginia Board of Architectural Review Agenda Item Summary March 4, 2015

Town of Gordonsville, Virginia Board of Architectural Review Agenda Item Summary March 4, 2015 Town of Gordonsville, Virginia Board of Architectural Review Agenda Item Summary March 4, 2015 AGENDA ITEM 6a New Business AGENDA TITLE: Consideration of COA for 308 N. High Street DISPOSITION: [X] Action

More information

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing. SECTION 076200 - FLASHING AND SHEET METAL PART 1 GENERAL 1.1 SECTION INCLUDES: A. Provide all labor, equipment, and materials fabricate and install the following. 1. Edge strip and flashing. 2. Counterflashings

More information

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights 1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 07 71 00 ROOF SPECIALTIES SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable in the

More information

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION ROOF MOUNTED ATTIC EXHAUST VENT SECTION 07 72 00 ROOF MOUNTED ATTIC EXHAUST VENT **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING Section 07 10 00 ROOFING AND WATERPROOFING Page 07 10 00-1 1. GENERAL REQUIREMENTS A. Indicate applicable American Society for Testing and Materials (ASTM) specification in this section. 01. Fire resistance

More information

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION 6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING SYSTEMS REQUIREMENTS ROOFING TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2 Group Elements. This

More information

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION 6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING SYSTEMS REQUIREMENTS ROOFING TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2 Group Elements. This

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS SECTION 08620 COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SPRI Updates and Improves Roof Edge Standards

SPRI Updates and Improves Roof Edge Standards DETAILS WRITTEN BY BY MIKE CHUCK ENNIS HOWARD, P.E. SPRI Updates and Improves Roof Edge Standards he effect of high winds on roofs is a complex phenomenon, and inadequate wind uplift design is a common

More information

Span-Lok hp, Curved Span-Lok, & SpanSeam Guide Specifications

Span-Lok hp, Curved Span-Lok, & SpanSeam Guide Specifications Span-Lok hp, Curved Span-Lok, & SpanSeam Guide Specifications MANUFACTURER - AEP SPAN 2141 Milwaukee Way, Tacoma, WA 98421, 800-733-4955 10905 Beech Avenue, Fontana, CA 92337 This Guide Specification is

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION

6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING B30 GENERAL SYSTEM DESCRIPTION 6. ENGINEERING SYSTEMS REQUIREMENTS B30 ROOFING SYSTEMS REQUIREMENTS ROOFING TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2 Group Elements. This

More information

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

Sapphire Metal Tile Roofing System

Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing System Sapphire Metal Tile Roofing Benefits of Sapphire Metal Tile - Beauty and function - Tile Beauty, Steel Strength, Lasts a lifetime - Excellent long term investment - Pays

More information

Give Your Great Roof the. Leading Edge. Metal Edge and Drainage Components

Give Your Great Roof the. Leading Edge. Metal Edge and Drainage Components Give Your Great Roof the Leading Edge Metal Edge and Drainage Components M E T A L E D G E A N D D R A I N A G E C O M P O N E N T S Exceptional Details for Exceptional Roofs. Even the World s Best Roof

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

LOG COLLEGE MIDDLE SCHOOL

LOG COLLEGE MIDDLE SCHOOL PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted plastic glazed skylights. B. Refer to roofing system sections for roofing accessories to be built into the roofing system

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

Buncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations

Buncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations Index of Drawings General G.00 COVER SHEET G.0 KEY PLAN 70 Westport Road G.0 STAGING PLAN ROOF AREAS: A, B, B, D, D, H, H, H, L AND L Architectural A.0 ROOF PLAN: AREA A, B AND B A.0 ROOF PLAN: AREA D,

More information

DIVISION 07 - THERMAL & MOISTURE PROTECTION

DIVISION 07 - THERMAL & MOISTURE PROTECTION DIVISION 07 - THERMAL & MOISTURE PROTECTION DESIGN CRITERIA General Design Requirements: 1. When designing roof access ladders and stairways to roof shall not be alternating tread type. 2. Provide 18 gauge

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification

More information

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors. PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Manufactured exterior cupolas. 2. Manufactured dormers. 3. Historical locomotive weather Vane. 1.2 PERFORMANCE REQUIREMENTS A. General:

More information

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES March 26, 2017 Page 1 DESCRIPTION PRODUCT FEATURES Factory fabricated metal wall siding/cladding with related flashings and accessory components. Online brochure available at: http://www.lenmak.com BASIC

More information

SECTION TURBINE VENTILATORS

SECTION TURBINE VENTILATORS SECTION 07 72 00 TURBINE VENTILATORS **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to suit your particular project.

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

SHEET METAL ROOF TEST REPORT

SHEET METAL ROOF TEST REPORT SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA

More information

Metal Roof Panels

Metal Roof Panels University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal

More information

a division of NCI Standing Seam Roof Systems

a division of NCI Standing Seam Roof Systems a division of NCI Standing Seam Roof Systems Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per square foot. When long life is required

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section. SECTION 10 5300 ALUMINUM WALKWAY COVERS Part 1 General 1.01 Related Documents A. The requirements of Division 1 specifications shall apply to work specified in the section. 1.02 References A. International

More information

ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services Addenda Dated: 01/16/2018 PURPOSE: The purpose of this Addenda #5 is to provide a

More information

SECTION METAL ROOF AND SOFFIT PANELS

SECTION METAL ROOF AND SOFFIT PANELS Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for

More information

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition

More information

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011 SECTION 07553 ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Elastomeric roofing membrane (EPDM), conventional application at low slope roof

More information

TremLock Metal Roofing and Wall Solutions

TremLock Metal Roofing and Wall Solutions TremLock Metal Roofing and Wall Solutions ROOFING & BUILDING MAINTENANCE TABLE OF CONTENTS PRODUCT SYSTEMS OVERVIEW APPLICATION TremLock Roofing and Wall Solutions...4-5 STANDING SEAM TremLock T-138 Roof,

More information

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC. 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ER 520 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00 00 THERMAL

More information

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS VELUX SECTION 08 62 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Dynamic dome unit skylight with formed curb counterflashing for mounting on site-built or prefabricated roof curbs, for flat, low-slope and

More information

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science Notes: Drawing Index T-1 Title R-1 Roof Plan - Existing Conditions R-2 Roof Plan - New D-1 Roof Details D-2 Roof Details S1.0 Safety Anchor Plan Building 709 Bull Street Columbia, 1 10/13 T-1 (Title Page)

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

Call for any further details including but not limited to material, temper, thickness, paint and design.

Call for any further details including but not limited to material, temper, thickness, paint and design. Material: extruded aluminum Fabrication Method: welded and mechanically fastened Finish: 2 part polyurethane paint powder coated Kynar finish available upon request Decking: aluminum interlocking pan Standard

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION

SECTION PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION Awning Works Inc Aluminum Decking Walkway Cover Specification CSI- Division 10 SECTION 10530 PRE-ENGINEERED EXTRUDED ALUMINUM DECKING WALKWAY COVERS SPECIFICATION PART 1 GENERAL 1.01 DESCRIPTION OF WORK

More information

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

July Minimum Fastening Requirements (Fully Adhered)... 5

July Minimum Fastening Requirements (Fully Adhered)... 5 EPDM POCKET GUIDE Mule Hide Products EPDM Field Installation Guide Mechanically Fastened and Fully Adhered Systems July 2017 Insulation Attachment Page Minimum Fastening Requirements (Fully Adhered)...

More information

WICOMICO COUNTY BOARD OF EDUCATION

WICOMICO COUNTY BOARD OF EDUCATION GLEN AVENUE ELEMENTARY SCHOOL RO REPLACEMENT PROJECT NUMBER: PSC #.00.9 SR CURRENT CODES: 05 INTERNATIONAL BUILDING CODE 05 INTERNATIONAL MECHANICAL CODE NATIONAL STANDARD PLUMBING CODE (MBPS) 05 EDITION

More information

DREXEL METALS CLIPS AND ACCESSORIES SIMPLIFYING METAL ROOFING SYSTEMS ARCHITECTURAL COMMERCIAL RESTORATION/CUSTOM

DREXEL METALS CLIPS AND ACCESSORIES SIMPLIFYING METAL ROOFING SYSTEMS ARCHITECTURAL COMMERCIAL RESTORATION/CUSTOM DREXEL METALS CLIPS AND ACCESSORIES SIMPLIFYING METAL ROOFING SYSTEMS Your machine makes one component of the total metal roof system. Drexel Metals has invested millions of dollars to ensure our metal

More information

Dist. by: BEST MATERIALS Ph:

Dist. by: BEST MATERIALS Ph: Dist. by: BEST MATERIALS Ph: 800-474-7570 www.bestmaterials.com Email: Sales@BestMaterials.com FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE Distributed by: BEST MATERIALS Distributed by:

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS VP ROOF SYSTEMS style SSR ROOF SYSTEM INTERLOCKING PANELS provide LONG TERM WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS 3 high ribs and 24 panel width allow for positive water drainage Available

More information

C. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense.

C. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense. PART 1: GENERAL 1.01 Scope Of Standard 1.03 Reference Standards 1.04 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for

More information

Grimes Elementary School Renovation September 7, 2010 Houston Independent School District SECTION 102800 - TOILET, BATH, AND LAUNDRY ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general

More information

P R O D U C T - S P E C

P R O D U C T - S P E C P R O D U C T - S P E C Drylight TM Skylight Specification Section 08600 Skylights June 2008 This PRODUCT-SPEC is intended to provide specifiers with guidelines to properly specify Carlisle s Drylight

More information

CREATIVE BUILDING SUPPLY

CREATIVE BUILDING SUPPLY CREATIVE BUILDING SUPPLY CBS P.O. BOX 299 50 PROSPECT ST. LAKEWOOD, N.J. 0870 PH.: 732 367-6333 FAX: 732 367-9568 E-MAIL: jimv@cbssheetmetal.com Meet The CBS Family: Creative Building Supply was founded

More information

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 07 72 00 ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING Project Name: Jefferson City Jaycees Fairgrounds Main Building Roof Replacement Project Site Address: 1445 Fairgrounds Road, Jefferson City, MO 65109 Project Contact: Randy Weaver Project Contact phone

More information

SHEET METAL FLASHING AND TRIM

SHEET METAL FLASHING AND TRIM SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES A. Mechanically attached system with thermoplastic roofing membrane. B. Insulation, flat and tapered. C. Flashings. D.

More information

DL-200. Specifications

DL-200. Specifications DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 3-6587 (562) 699-03 www.icc-es.org ESR-3743 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL

More information

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING EXARC Skylights, Inc (800) 247-5934 3793-B North Peachtree Road (770) 451-4352 Chamblee, GA 30341 fax(770) 451-4934 EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING PART 1 GENERAL 1.1 RELATED

More information

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016 PART 1: GENERAL 1.01 Scope Of Standard 1.02 Reference Standards 1.03 Quality Control A. This standard provides general guidance concerning the specific preferences of the Sam Houston State University for

More information

SECTION METAL ROOF & WALL PANELS

SECTION METAL ROOF & WALL PANELS This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2000 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a

More information

Wall Louvers (10200)

Wall Louvers (10200) Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses.

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 07620 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System TCC-1 Pipe Penetration System TCC-3 Pipe Penetration System TCC-5 Pipe Penetration System 54 years of excellence... www.thybar.com 82 Table of Contents General Information 84 Specifications 85 Assembly

More information

Perimeter edge metal for low slope roofs. Copings, gravel stops, roof edging, gutters, downspouts, reglets and trims.

Perimeter edge metal for low slope roofs. Copings, gravel stops, roof edging, gutters, downspouts, reglets and trims. Perimeter edge metal for low slope roofs. Copings, gravel stops, roof edging, gutters, downspouts, reglets and trims. Cumming Aquatic Center Photo Courtesy G. Gotfredson Metal Edge Systems engineered and

More information

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS) ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES 1.. 3. Scope

More information

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR SECTION 07 72 00 ELECTRICAL POWER ATTIC EXHAUST VENTILATOR **This is a CSI Three-Part Specification using CSI MasterFormat 2004-2010 Section Numbers and Titles. This specification must be edited to delete

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Engineering Services Program

Engineering Services Program Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International Building

More information

SSL-175. Specifications

SSL-175. Specifications SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES

More information

Options In Flashing for Asphaltic and Single-Ply Systems Brochure

Options In Flashing for Asphaltic and Single-Ply Systems Brochure Options In Flashing for Asphaltic and Single-Ply Systems Brochure Updated: 1/12 www.gaf.com OPTIONS IN FLASHING for Asphaltic and Single-Ply Systems www.gaf.com All roofing professionals recognize that

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural roofing system of preformed steel panels. B. Fastening system. C. Factory finishing. D. Accessories and miscellaneous components.

More information

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

FACE CFP - HORIZONTAL PANELS - OPTION 'B' - Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF

More information

Firestone UltraPly TPO The light colored roofing choice

Firestone UltraPly TPO The light colored roofing choice TM Firestone UltraPly TPO The light colored roofing choice TPO Roofing Systems Firestone UltraPly TPO roofing systems Firestone: over a century of experience Firestone Building Products entered the commercial

More information

NRM-7000 Guide Specifications

NRM-7000 Guide Specifications NRM-7000 Guide Specifications MANUFACTURER www.nuraymetals.com sales@nuraymetals.com 800-700-7228 SECTION 07 411 PREFORMED ROOF & WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes complete system

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS 1. PART 1 GENERAL 1.1 WORK INCLUDED: 1. Provide labor, material, equipment and services to furnish and install aluminum windows shown on drawings and specified herein. Window

More information

SECTION FLASHING AND SHEET METAL

SECTION FLASHING AND SHEET METAL PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 60 00 1. Use section only for NCA projects. 2. Delete or edit text in // // if not applicable to project. Also delete any other paragraph not applicable in the

More information