1 GASCOGNE Implementation Guide Edition of August 21st, 2007 PMA by Arval ZA du Pays de Podensac CERONS - France Tel. +33 (0) Fax. +33 (0) commercial@pma.fr
2 SYSTEM DESCRIPTION The Gascogne panel is a piece of siding made of stainless or pre-coated galvanized steel with a nominal thickness of at least 1 mm. These panels fit together by their longitudinal edges, and the attachments are no longer visible after installation.(technical drawings nb.1&2+5) This panel is notably used for add-on siding, designed with a vertical or horizontal arrangement of joist between the panels. The macimum recommended span is 1.50 m between supports. This product can be used on new or renovated public or private buildings used for commercial or lodging purposes.(technical drawings nb.3&4) Gascogne siding does not participate in the general stability of the building (no wind bracing or anti-buckling functions). The support wall must provide the strength functions and stability of the façade and meet requirements in the matter of air permeability. TECHNICAL CHARACTERISTICS Manufacture: by bending (technical drawings nb.1 to 4) Useful width : 300 mm ± 1 mm. Nominal height : 75 mm +0 mm/-1 mm Length 1000 mm 5000 mm maximum +0mm/-3 mm MATERIALS Thickness (mm) Steel Stainless Steel 1 1 Grade Standard S320 GD + Z 225 or Z primary NF EN P X5 Cr Ni or X2 Cr Ni NF EN Protection Quality pre-coating colorissime ARVAL Post-coating by polyester dusting (mini 60µm depending on color) Possibility pre-coated Colorinox PVDF 36 µm Standard XP P34301 P P PMA should be consulted of the feasibility of various colors and surface appearances: Pre-coated and pearly steel: Colorissime color chart by Arval, Steel post-coated by dusting: RAL color chart.
3 FINISHING ELEMENTS They are manufactured from th same plates (same thickness, same quality of material) as the panels in a maximum lengths of 6 m. Various connections (technical drawings nb. 28 to 31) Outside and Re-entrant corners (technical drawings nb.16 to 24) Acroterion crown (technical drawings nb. 6 to 11 ) Flaps (technical drawings nb. 12 to 15 ) Window frames (technical drawings nb.25 to 27 ) ASSEMBLY PRINCIPLE GASCOGNE panels are designed to be installed on a ruled secondary frame allowing a ventilated fiom of air to flow between the panels and the support wall or possible thermal insulation. This frame is to satisfy the requirements of C.S.T.B. Book no JanuaryFebruary «General conditions for design and implementation of the metal framing and thermal insulation of add-on siding». This secondary frame is a construction element by itself and is not an integral part of the Gascogne process. Nevertheless, proper execution is a condition for the final result, notably as concerns the appearance of the facing. The presence of a secondary framing is systematically required, including in the case of double-skin sinding with metallic plates in internal skin. It serves as bearing and attachment support for the siding. PARTICULAR ARRANGEMENTS FOR THE FRAME No frame alignment of flatness erros can be compensated by the GASCOGNE panels themsleves. The allowable loads and spans of the GASCOGNE panels under normal climatic conditions have been determined by tests considering the following criteria :. Deflections of at most 1/200th of the span for the longitudinal edges. Safety coefficient with respect to ruin greater than 2 For aesthetic considerations, it is also advised to limit the spans to 1.5 m. GASCOGNE panels are installed and attached on metal rails with the following characteristics:. Bearing width of at least 40 mm. The thickness of the secondary frame sections must notably allow construction of assemblies with a minimum characteristic strenght of 300 dan. Normal wind loads allowable on GASCOGNE panels in 10/10ths steel, in dan/m², Pressure & Vaccuum Simple span 2 supports Vacuum Pressure 218 Span in (m) Continuity 3 supports or more Pressure Vacuum
4 Tests carries out on pre-coated steel panels (S320 GD + Z 225) Weight : 16,5 kg/m² For panels in stainless steel, a 20 mm pincer can achieve allowable loads comparable to those of panels in pre-coated steel. CONDITIONING AND TRANSPORT A delivery note is glued to each package stating: Customer order reference, Batch reference Customer name Type of product Facing thickness Bundle content (number and length) Color reference of pre-coated plates. GASCOGNE panels are packed on the production line. The weight of the bundles may in no case exceed 2.5 tons. GASCOGNE panels and their accessories are to be transported under conditions that preserve the integrity of the characteristics (shimmed up packages, carefully stacked and strapped, tarpaulin-covered trucks). ORGANISATION The PMA company is the product manufacturer and does not install the product. GASCOGNE panels are to be installed by constractors having the required professional qualifications. Design and studies prior to executing the facade are not incumbent on the maker PMA nor on the distributor companies. On request, PMA can provide technical assistance. The purpose of the present specification is not to give details on all points of implementation but to state the main technical definitions of the panels and their particular characteristics. To help in the study of the facades, it is complemented in the appendix with particular design suggestions and finishing elements. HANDLING, STORAGE AND MAINTENANCE Handling operations are carried out in consideration of the particular features of the products. They are to be handled vertically on edge. The panels are stored in bundles, slightly inclined in the longitudinal direction on a flat surface, without stacking more than two packags. Storage time on the work site is to be reduced to the minimum. The essential precaution consists in avoiding water from entering by runoff or condensation between the panels. Store sheltered from sunlight. The peel-off protective film covering GASCOGNE panels is to be removed as work advances, at the latest 15 days after shipment.
5 Metallic facades have to be normally maintainted in accordance with the prescriptions of the Professional Rules for Metallic Siding (article exterior maintenance). Although naturally cleanable by runoff of rainwater, if needed, they can be cleaned periodically with household detergent, without chlorine added, with no use of abrasive or solvent, followed by rinsing with fresh water. Mainteance notably consists of: Eliminating various vegetation (such as moss) and any incompatible matter that might be deposited on the facing surface. Repair of any localized degradation as soon as detected, such as incipient corrosion caused, for example, by exterior deterioration actions. Cutting and drilling Custom manufacture makes it possible to limit the cutting on the work site. As required, cutting operations on site are performed using the appropriate equipment (jigsaw, nibbler, fine-tooth saw). It is strictly prohibited to use a grinder wheel. Watch out to avoid hot particles from being incrusted on the coating. All dirt (filings, drilling chips, etc...) are to be eliminated immediately. DRAWINGS OF DETAILS OF PRINCIPLE The following drawings are examples of how singular point of GASCOGNE panels are treated. Any other solutions can be considered and studied by the installing contractor in consideration of the specific characteristics of the products.
6 For any further information, please consult us: IMPORTANT The content of this document is based on data relative to construction and to material properties. It is designed to assit PMA customers in implementing its products. Based on the construction processes and methods known at the time of its publication, this Implementation Guide cannot be considered final and may be revised and/or modified at any time. In case of doubt or difficulty, the user is asked to consult PMA before continuing his project.
7 TECHNICAL DRAWINGS Useful width 300 mm GASCOGNE panel steel 10/10 nb.1 GASCOGNE panel vertical section nb.2
8 GASCOGNE double-skin panel nb.3 GASCOGNE add-on siding nb.4
9 Sense of installation Attachment detail vertical section nb.5 Acroterion Crown nb.6
10 Acroterion crown Detail nb.7 en ml u m xi Ma gth 6 m 0 00 m Acroterion X, Y and Z as per request nb.8 Fish plate Thickness 1mm nb.9
11 Acroterion for double skin cladding nb.10 Acroterion for add-on siding nb.11
12 Flap vertical section ne Gascog Ruled secondary frame panel As requested Perforated flap Thickness 1mm Begining pin Thcikness 1mm nb.12 Perforated flap x ma h t ng Le m 0m th ng Le x ma mm Perforing following hight of the facade to be ventilated nb.13
13 Flap for double-skin cladding nb.14 Flap for add-on siding nb.15
14 Outside right corner nb.16 nb.17 nb.18 nb.19
15 Right outside corner nb.20 Right entrant corner nb.21
16 Right entrant corner Horizontal section Right entrant corner Gascogne panel nb.22 Splice piece nb.23 nb.24
17 Window frames nb.25 Window frames horizontal section Window frames vertical section Secondary ruled frame Gascogne panel Perforated lintel (ventilation+evacuation of moisture) Sealant Jamb against riser Jamb against riser Window rest flap Ventilation Gascogne panel nb.26 nb.27
18 Vertical divisor nb.28 Vertical divisor Thickness 1mm nb.29 Acroterion crown vertical section Lenght 6000 mm Vertical Divisor Acroterion Divisor X as the acroterion covers the divisor nb.30 Attention: For a use of the divisor the width of the acroterion (X) must be sufficient to cover the high part of the divisor. nb.31
ECAILLE Implementation Guide
-1- ECAILLE Implementation Guide Published 21 August 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr -2PRESENTATION
More informationMASCARET Implementation Guide
MASCARET Implementation Guide Edition of August 21st, 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr -2-
More informationST PRODUCTS Implementation Guide
ST PRODUCTS Implementation Guide Edition of 24 october 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr -2SYSTEM
More informationOXYGEN Implementation Guide
OXYGEN Implementation Guide Published on 21 August 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr PRESENTATION
More informationCASSETTE SP Implementation guide
CASSETTE SP Implementation guide Published on 21 August 2007 PMA by Arval ZA du Pays de Podensac 33720 CERONS - France Tel. +33 (0)5.57.98.14.50 Fax. +33 (0)5.57.98.14.60 commercial@pma.fr www.pma.fr PRESENTATION
More informationCASSETTE BS Specification book
CASSETTE BS Specification book Edition: April 2011 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval PRESENTATION OF THE SYSTEM
More informationKingspan Day-Lite Klick
Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation
More informationGENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS
I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green
More informationSECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES
SECTION 05440- PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section includes pre-engineered, pre-fabricated cold formed steel framing elements. Work includes:
More informationExterior System installation instructions
Exterior System installation instructions 11/20/14 WPS ES-400 & 500 INSTALLATION INSTRUCTION. The WPS ES-400 & 500 systems Façade panels are designed for use as an external wall cladding in conjunction
More informationPART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002
SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall
More informationProduction Technology
Introduction There has been a need to introduce new QUALITY PRODUCTS in the construction & Cold Storage industry in the region for many years. EIP was set up at Dubai Investment Park in the UAE to address
More informationRUUKKI FORMA DESIGN INSTRUCTION
www.ruukki.com RUUKKI FORMA DESIGN INSTRUCTION 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize
More informationArcwall. Rain Screen Wall System
Rain Screen Wall System is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines excellent performance
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationArcwall. Rain Screen Wall System
Arcwall Rain Screen Wall System Arcwall is an economical drained and back-ventilated rain screen system for both walls and soffits manufactured from formed aluminum or stainless plate. The system combines
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationOpus Interior wall facing system in zinc.
INTERIOR Opus Interior wall facing system in zinc. Registered design Specification and installation guide Presentation of the system Advantages The elegance of preweathered VMZINC Invisible fixing Individual
More informationSECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES
SECTION 05 44 00 (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES PART 1 GENERAL 1.1 SUMMARY A. Section includes pre-engineered, pre-fabricated cold-formed steel framing
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationFor more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding
New CI/SfB (41) R December 2008 Pictura High performance cladding Introduction The new Pictura coating system incorporates an additional surface treatment for Fibre Cement panels. The main characteristic
More informationSECTION COLD-FORMED METAL TRUSSES
SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAquaroc Fibre Cement Board
Fibre Cement Fibre Cement Description Characteristics is an asbestos-free, cellulose fibre reinforced cement board that is very dense with a non-porous surface. The excellent moisture resistant characteristics
More informationRUUKKI FAÇADE SYSTEMS
www.ruukki.co.uk RUUKKI FAÇADE SYSTEMS 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize the
More informationGA APPLICATION OF GYPSUM SHEATHING
1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior
More informationSECTION STAINLESS STEEL WALL PANELS
SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.
More informationSECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES
SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.
More informationPromistyl 3005T - roofing
Metal Cladding Panel reference Arval Globalroof Promistyl 3005T ribbed face fix composite fire rated roofing panels Arval Promistyl 3005T Manufacturer ArcelorMittal Lammerdries 82440 Geel Belgium web site:
More informationBEARING METAL STUD FRAMING
L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or
More informationRAINSCREEN CLADDING. Bespoke secret fix Rainscreen cladding system available in range of materials and finishes. Delivering your design
RAINSCREEN CLADDING Bespoke secret fix Rainscreen cladding system available in range of materials and finishes. Delivering your design Bailey Rainscreen cladding systems provide a bespoke solution to your
More informationResysta Wall Cladding Installation Guidelines
Resysta Wall Cladding Installation Guidelines NOTE: Proper planning of the wall cladding layout is essential for ease of installation of wall cladding boards and wall cladding components. Thoroughly read
More informationGuideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
More informationThermaSteel Corporation ASSEMBLY MANUAL
ThermaSteel Corporation ASSEMBLY MANUAL TABLE OF CONTENTS 1- INTRODUCTION 1.1 THERMASTEEL TM WALL PANELS 1.2 Drawing and Element Numbers 2- ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation of Foundation
More informationSPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)
SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF Two Sided Structurally Glazed Curtain Walling (Horizontal Structural joints) Issue date Revision Comment R0 Draft 05/05/09 R1 Approved
More informationSECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS
SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationSamrat External Wall Cladding.
Samrat External Wall Cladding www.samratcladage.com Wall Cladding Dictionary Meaning A covering or coating on a structure or material. Definition Is an application of one material over another to provide
More informationFundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL
Fundamentals of Insulated Panel Installation MBCEA 2016 Clearwater, FL Fundamentals of Insulated Panel Installation Industrial Roof & Walls Not Architectural Not Cold Storage Topics Preparation Installation
More informationExternal Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185
Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
More informationSECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE
SECTION 08 33 00 SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2013 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2013 Application and Finishing of Gypsum Panel Products. Each
More informationBioclimatic Pergola with ajustable blades
Technical documentation V4 Bioclimatic Pergola with ajustable blades Summary Pages The bioclimatic pergola with adjustable blades Key words: ADAPTABILITY and MODULARITY Optimize your installation DTS study
More informationVertigo Cladding Board
Installation guide Vertigo Cladding Board Geolam: a stunning alternative to wood cladding Vertigo is a composite wood cladding board requiring minimum maintenance. Durable and fade resistant, it will not
More information1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights
1 Exam Prep Application and Finishing of Gypsum Board GA-216-2016 Tabs and s These 1 Exam Prep Tabs are based on the Gypsum Association GA-216-2016 Application and Finishing of Gypsum Panel Products. Each
More informationSPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling
SPECIFICATION For the Supply and Installation of BRITAL UN-4-76 Four Sided Unitized Structurally Glazed Curtain Walling Issue date Revision Comment 07/05/09 R0 Draft 11/05/09 R1 Approved for Issue R1 Amended
More informationSculpted 3D Minimal. Rain Screen Wall System
Sculpted 3D Minimal Rain Screen Wall System Metalwërks Sculpted frees designers to create iconic facades more easily and affordably than ever before by elevating three-dimensional wall panels to entirely
More informationdanpalon glazing system - housing Product BRANZ APPRAISAL No. 526 (2006) Scope Everlight NZ Ltd P O Box Whenuapai Waitakere 0662 Auckland
Product 1.1 The Danpalon Polycarbonate Glazing System is designed for use as roof and wall glazing in housing and similarly constructed buildings. Danpalon is available in two profile types, Danpalon Multicell
More informationSYSTEM W-H 1100 Wall cladding. Metal product
SYSTEM W-H 1100 Wall cladding Metal product :::: 3 WALL CLADDING SYSTEM W-H 1100 APPLICATION AREA n Acoustic element n Cladding or covering element n Architectural room-design element n Combination of
More informationSECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS
SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationHome Depot Page 1 of 5 HDPB Humacao, PR 10/19/09
PART 1 - GENERAL 1.01 SUMMARY A. Types of cold-formed metal framing units include the following: 1. C-shaped steel studs B. Related work specified elsewhere includes but may not be limited to: 1. Section
More informationECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals
ECOPLY BARRIER FOR STEEL s Technical Assessments of products for building and construction. Carter Holt Harvey Plywood Limited Private Bag 92-106 Auckland Tel: 0800 326 759 Fax: 09 633 1582 Web: www.chhwoodproducts.co.nz
More informationPlanning and installation instructions
Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...
More informationFlushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide
Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal
More informationSRP-AirOutshield UV Issued:
SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing
More informationSECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS
SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2810 Reissued 02/2018 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationEQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.
This specification has been numbered, organized and formatted in accordance with the MasterFormat, Section Format and Page Format documents published jointly by Construction Specifications Institute (CSI)
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationSECTION FIBER CEMENT SIDING. A. Furnish and install CERACLAD fiber cement rain screen siding system.
SECTION 07466 FIBER CEMENT SIDING PART 1 GENERAL 1.1 SCOPE A. Furnish and install CERACLAD fiber cement rain screen siding system. 1.2 RELATED SECTIONS A. Division 06 - Wood and plastics B. Section 07210-
More informationSandwich panel SPA Product description
Sandwich panel SPA Product description Ruukki offers a sandwich panel system that combines an attractive appearance with excellent thermal insulation and fire-resistance. The panels are of a lightweight,
More informationA. Meet at Project site <insert number> days before starting installation.
SECTION 074643 - COMPOSITION SIDING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Engineered wood cladding. 2. Soffit panels. 3. Trim and fascia. 4. Sealant. 5. Weather barrier. 6. Flashing. 1.2
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationProduct Guide Specification
ALGRIP Manufactured by April 2017 104 North Maple Avenue P.O. Box 646 Leola, Pennsylvania 17540 Toll Free 800-345-8170 Fax 717-656-2041 Website www.algrip.com / www.rosstechnology.com E-mail sales@rosstechnology.com
More informationAmeriplate. Rain Screen Wall System
Ameriplate Rain Screen Wall System Efficiency and fascinating free-floating effects are hallmarks of Metalwërks Ameriplate wall systems. With Ameriplate, the cut edges of the face plate material are the
More informationSiding Installation Manual for: Color Natura Rustica Rivets
Siding Installation Manual for: Color Natura Rustica Rivets 1 Ventilated Siding, Principle For easy handling of the Panels use when mounting Ventilated Siding systems consist of five main components: 1
More informationC. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with
SECTION 06 17 53 PART1 - GENERAL 1.01 A. SUMMARY Section Includes installation of the following products which have been purchased and delivered to the project site under a separate contract: 1. Wood roof
More informationINSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene
INSTALLATION MANUAL METAL INSULATED PANELS -ROXUL -Expanded Polystyrene Insulated Metal Panels London Eco-Metal Manufacturing Inc. **Also see Eco-Metal s Handling Manual** These instructions are provided
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationCONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.
SECTION NUMBERS AND TITLES IN THIS SPECIFICATION UTILIZE MASTERFORMAT 2004. THIS SPECIFICATION GUIDE IS WRITTEN ACCORDING TO THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) THREE-PART SECTION FORMAT (1998)
More informationGold Bond BRAND Gypsum Sheathing
BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant
More informationA. Product Data: For each type of cold-formed steel framing product and accessory.
SECTION 05400 - COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior non-load-bearing wall framing. 1.2 ACTION SUBMITTALS A. Product Data: For each type of cold-formed
More informationCl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.
Cl/SfB 1 (4-) RJ7 1 1 1 July 2010 Cempanel BUILDING BOARD CEMENT PARTICLE BOARD Cempanel Class 0 cement particle board with excellent impact, fire and acoustic properties. Its durability, consistently
More informationH92 RAINSCREEN CLADDING
TO BE READ WITH PRELIMINARIES/GENERALCONDITIONS TYPES OF CLADDING Plasmet PR-200 Aluminium Rainscreen System comprising of 3mm thick polyester powder coated cassette panels with riveted aluminium fixing
More informationZINC. Product Data Sheet
ZINC Benchmark Zinc system is available in two different cassette options in a range of finishes and is installed onto a specifically designed Benchmark. Images above courtesy of VMZinc FAÇADE DATA Materials
More informationECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017
ECOPLY RIGID AIR Amended 21 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Carter Holt Harvey Plywood Ltd Private Bag 92-106 Auckland Tel: 0800 326 759 Fax:
More informationCentral Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS
Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society
More information70S - 132S SUN LOUVRE. Sun Control Systems
70S - 132S SUN LOUVRE www.luxalon.com Sun Control Systems Luxalon 70S - 132S Sun Louvre System Description The Luxalon 70S and 132S Sun Louvre system consist of sturdy Z-shaped panels. The panels are used
More informationCERTIFICATE No VTT-C Date of issue
NAME OF PRODUCT CERTIFICATE No VTT-C-9190-12 Date of issue 3.12.2012 CERTIFICATE HOLDER ACTIS SA Avenue de Catalogne 11300 Limoux France MANUFACTURER ACTIS SA PRODUCT DESCRIPTION is a vapour control multifoil
More informationTable of Contents. Certificates and approvals Colour palette...52
Table of Contents "krono-plan" facade systems...2 1. Introduction...3 2. Facade system...4 3. Gaps and joints between the Kronoplan laminate panels...5 4. Corners...6 5. Visible joints. Aluminium structure
More informationSECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM
SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationFlotation Docking Systems, Inc.
GENERAL SPECIFICATIONS The following data outlines the design calculations and specifications around which Flotation Docking Systems, Inc. products are constructed. The use of such information for contract
More informationOmniplate Barrier Wall System
is an economical barrier wall system with visible caulk joints at all horizontal and vertical panel joints. As a barrier wall, serves as the primary weather barrier for the building envelope. It can be
More informationInstallation guidelines System: Cofraplus 220
Edition: February 2012 Installation guidelines System: Cofraplus 220 ArcelorMittal Construction International Industriestrasse 19 8112 Otelfingen / Zürich Switzerland www.arcelormittal.com/arval Summary
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationSECTION COLD-FORMED METAL FRAMING
SECTION 05.40.00 COLD-FORMED METAL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Cold-formed metal framing for: B. Exterior load-bearing steel stud walls. 1. Interior load-bearing steel stud walls. 2.
More informationHEAVY STEEL CONSTRUCTION
HEAVY STEEL CONSTRUCTION PRE-ENGINEERED PRE ENGINEERED STEEL BUILDINGS Prismatic Constructions Work Shops, Storage Buildings etc. Figure 1 Figure 2 Prismatic steel constructions can be manufactured as
More informationOS-ALD ACOUSTIC LOUVERS
OPTIMA Acoustic Louvers Overview OPTIMA Acoustic Louvers are designed to provide optimal acoustic performance (noise reduction) with minimal airflow restrictions. OS-ALD acoustic Louvers are typically
More informationFabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Klick KS500 DLKK
Fabrications, Safety & Lighting Solutions Kingspan Day-Lite KS500 DLKK Applications Kingspan Day-Lite is a secret-fix wall light system typically suited for vertical applications. Featuring an innovative
More informationSECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS
SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationSpecifying Pre-Engineered CFS Floor and Roof Trusses 551f-98
Archived Technical Note Cover Page Cold-Formed Steel Engineers Institute (CFSEI) Technical Notes are reviewed and revised on a regular basis. Often, during the review process, the evaluation of the note
More informationA M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N
A M E R I C A N A R C H I T E C T U R A L AAMA 2410-13 Standard Practice for Installation of Windows with an Exterior Flush Fin Over an Existing Window Frame M A N U F A C T U R E R S A S S O C I A T I
More informationSeries 3000 Pocket Doors
Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification
More informationSECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS
SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM
SYSTEM TEN66 INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630) 355-4995 www.omnis-panels.com
More informationSECTION METAL ROOF PANELS
SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof
More informationSECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE
SECTION 08 33 00 SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More information