Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

Size: px
Start display at page:

Download "Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide"

Transcription

1 Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016

2 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels and building envelope solutions. Insulated panels serve as energy efficient, state-of-the-art alternative to traditional construction. This document serves as installation guidelines for the BENCHMRK by Kingspan Flushglaze 7500 window system. Disclaimer This installation guide is only to be used in conjunction with panel installation drawings and Kingspan recommended details. Details shown in project shop drawings take precedence over any similar information in this manual. Shop drawings may be prepared either by Kingspan or by the panel contractor. Kingspan Technical Service Department is available to assist the panel contractor in the review of shop drawings. This guide is intended to provide the panel contractor with recommended methods, procedures and guidelines for the installation of the Flushglaze 7500 window system for architectural applications. Information presented is accurate but may not cover all situations, building conditions and/or details of your specific project. Consult Kingspan Technical Services where this guide does not cover your unique construction requirements. It is the sole responsibility of the project engineer and panel installer to ensure specified air and weather tightness of a building by good design and workmanship in accordance with approved drawings using only the appropriate type of sealants. It is the sole responsibility of the owner s representative and panel installer to maintain quality workmanship in accordance with approved shop drawings to ensure the best performance of the wall system. Kingspan recommends installers read this document fully before receiving the panels on the job site. Installation classes are available through Kingspan s Technical Services Department. Please call for more information. Follow the architect s approved shop drawings and engineering calculations for your project specific fastening patterns. The engineer of record is responsible for verifying applicable design loads and panel fastening requirements. ll safety procedures, including adequate fall protection, are the responsibility of the panel contractor. 2

3 CONTENTS Introduction 4 Installation 6 3

4 1. INTRODUCTION FLUSHGLZE FETURES Flushglaze 7500 provides integration with curtainwall type window construction for thru-tube applications. Includes a wide array of panel adapter extrusions, curtainwall components and modified panel edge options to suit specific window / panel applications. Designed to preserve and maintain the same weather proofing principles as insulated metal panels. 1. Versatile system that readily adapts itself to different construction needs. Window head 2. ll components are thermally broken. 3. Well suited for steel thru-tube clad-over applications as well as aluminum thru-tubes. 4. ppealing in both aesthetics and function with no secondary flashings or additional sight lines. 5. Window systems are reglazable without dismantle of insulated metal panel system. Window sill 6. Integrates with Designwall, 2000 Shadowline and 2000 Ribbed. Snap cover 4

5 2. INSPECTION UPON DELIVERY FLUSHGLZE 7500 Flushglaze 7500 components are carefully packaged then shipped on flat bed trailers to the construction site. When a shipment is received, check all items against the shipping document for quantities, dimensions, colors, transit damage, etc. Document any shortage of materials or damage on the bill of lading and have it signed by the driver. It is the receiver s responsibility to make any damage claims immediately. Please note that although every effort is made to prevent shipping damage, Kingspan is not responsible for damage which may occur during transportation, delivery, storage or on-site handling. 3. STRUCTURL LIGNMENT FLUSHGLZE Review shop drawings prior to installation to verify that structural members are in the correct location. 3.2 Installer must examine the alignment of the structural steel before installation of the window system. The walls must be square, and support members to which extrusions are attached must be in the same plane, flat and free of obstructions such as weld marks, bolts or screw heads. Support members shall be: a. Plus or minus 1 /8 (3.17 mm) in 5 feet (1524 mm) in any direction along plane of framing. b. Plus or minus 1 /4 (6.35 mm) in 20 feet (6096 mm) cumulative in any direction along plane of framing. c. Plus or minus 1 /2 (12.7 mm) from framing plane on any elevation. d. Plumb or level within 1 /8 at all changes of wall direction for preformed corner panel applications. ny variance from tolerances can affect performance, aesthetics, and installation and must be reported to the general contractor, and corrected by the responsible party before panel installation begins. 5

6 4. INSTLLTION FLUSHGLZE Slip the tube cover extrusion over each steel tube from the back side at window locations. Run verticals 3 past head and sill. 4.2 Fasten tube cover extrusions to the steel tubes with #14 fasteners above head and below sill. 6

7 4.3 Install shear blocks at all horizontal member locations with appropriate stainless steel fasteners. 4.4 Seal face, top, bottom and screw tracks of shear blocks with high grade silicone. 7

8 4. INSTLLTION FLUSHGLZE Install two piece open-back horizontal interior members onto shear blocks per standard curtainwall application fit between vertical tube covers. C Screw through the front with appropriate stainless steel fasteners into the shear blocks to hold the horizontal members in place. B Slide the horizontal onto the shear block. D Snap on the cover plate to complete the horizontal. 8

9 4.6 B If the veneer extrusion was not part of the horizontal member, install the veneer extrusions at this time onto the horizontal members using appropriate stainless steel fasteners every 12 on center. Install veneer extrusions onto the vertical members using appropriate stainless steel fasteners every 12 on center stop short of horizontal members at the top and bottom of window. C D Notch the vertical veneer extrusions at the top and bottom horizontal members (do not notch for intermediate horizontals). Seal over all fasteners with silicone sealant. 9

10 4. INSTLLTION FLUSHGLZE B Install interior gaskets onto all veneer extrusions and horizontal members. Seal at all gasket corners. Install plastic joint plug fillers (zone plugs) set in silicone sealant at all intermediate intersections within the window frame where the veneer extrusion is not continuous. C t the top and bottom of the window frame, install ssg bridge and plastic joint plug filler set in silicone sealant to connect the veneer extrusions. B Seal at gasket corner 10

11 4.8 B Field cut panels to suit. Install the sill adapter extrusion with the thermally broken glazing channel onto the cut panel bed, sealed in urethane sealant. C D ttach the adapter with pop rivets on the front and back every 12 on center and run a bead of continuous butyl sealant along the backside of the panel and the extrusion to meet the vertical sealants of the panel system. Install the panels below the window sill. lternatively, a modified glaze in edge panel may be manufactured for this condition. Sill adapter extrusion Bed seal in urethane sealant Pop rivet every 12 Modified edge with thermally broken glazing seal Continuous butyl sealant 11

12 4. INSTLLTION FLUSHGLZE Install thermally broken head adapter extrusion with starter clips and appropriate fasteners at each vertical support. C Install non-skinning butyl sealant to the back leg of the window head adapter extrusion. B If the head adapter extrusion must be spliced, use 3 /8 thick urethane foam compression pads with peel off backing at all extrusion splices (compress 33% to 1 /4 ). D 1 /4 weep holes must be drilled in the front leg of the adapter extrusion every 24 on center. Foam splice pad Continuous butyl sealant Starter clip Insulative foam blocking 1 /4 weep holes at 24 on center 12

13 4.10 Install panels above window head. 13

14 4. INSTLLTION FLUSHGLZE Setting blocks (2 per lite near each bottom corner of the window) to be provided by Kingspan and placed by glazer. C Glass to be furnished and installed by others under separate glazing contract. B Setting blocks to be located per approved shop drawings or dead load charts. Setting blocks 14

15 4.12 Install pressure plates with exterior glazing gaskets, thermal break gasket and appropriate stainless steel fasteners every 9 on center. Effectively connect all seals with silicone at corners. Torque all screws to 95 to 100 pounds. *Note: Before installing pressure plates apply a generous amount of sealant to the face of the joint plugs and SSG bridges. C D Run the horizontals continuous and fit the vertical pressure plates between the horizontals. Seal between all pressure plates and head / sill end cap. This seal is to join and adhere to the joint plug and ssg bridge seals. B There must be two 5 /16 weep holes per daylight opening in the pressure plate approximately 1 left and right of the mullion. 5 /16 weep holes Fastener every 9 Thermal break gasket Exterior glazing gasket 15

16 4. INSTLLTION FLUSHGLZE B Install the cover caps over the top of the pressure plates. There must be two 5 /16 weep holes per daylight opening approximately 1 left and right of each mullion. C Run the horizontals continuous and fit the verticals between the horizontals. 5 /16 weep holes 16

17 4.14 n angular mending plate is required at the jamb of the windows. Caulk this mending plate to the window frame using non-skinning butyl tube sealant the full height of the jamb. B This sealant must be married to the top glazing gaskets at the window head and the bottom glazing gaskets at the window sill. This will complete a continuous perimeter seal at the window to panel connection. Mending plate angle sealed to window jamb 17

18 NOTES 18

19 NOTES 19

20 BENCHMRK Support BENCHMRK By Kingspan Columbus, OH, US Modesto, C, US Caledon, ON, C Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof.

Installation Instructions

Installation Instructions Installation Instructions 400SS Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised June 2016 dependable@tubeliteinc.com Page 1 TABLE OF

More information

Series Silicone structural glazed. Installation Instructions

Series Silicone structural glazed. Installation Instructions Series 5600 Silicone structural glazed Installation Instructions Part NO. Y306 May 2016 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines 3-4 II. Perimeter Applications. 5 III. Anchor Installation.

More information

Series Silicone structural glazed curtain wall. Installation instructions

Series Silicone structural glazed curtain wall. Installation instructions Series 5900 Silicone structural glazed curtain wall Installation instructions Part NO. Y354 July 2015 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines.. 3-4 II. Perimeter Application..... 5-6

More information

YCW 250 I-Beam Curtain Wall System Installation Manual

YCW 250 I-Beam Curtain Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS INSTALLATION NOTES..................................... Page ii PARTS DESCRIPTION Framing

More information

Duracast Pressure Plate Installation Instructions

Duracast Pressure Plate Installation Instructions July 2015 EFCO CORPORATION 7/2015 PART NO. YW45 1 TABLE OF CONTENTS SECTION S-5600 / S-5900 DURACAST PRESSURE PLATE PAGE I. General Notes and Guidelines. 3-4 II. Glazing Preparation & Installation... 5

More information

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS SECTION E INDEX CURTAINWALL FRAMING SYSTEMS E PAGE DESCRIPTION 0 CURTAINWALL FRAMING SPECIFICATION 0 SERIES /" () WIDE THERMALLY IMPROVED CURTAIN WALL FRAMING SYSTEM FOR SEALED UNIT GLAZING. 00 SERIES

More information

Series Outside glazed curtain wall. Installation instructions

Series Outside glazed curtain wall. Installation instructions Series 5900 Outside glazed curtain wall Installation instructions Part NO. Y350 July 2015 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines 3-4 II. Perimeter Application...... 5-6 III. Anchor

More information

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV

More information

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13)

1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13) 1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE 162-904 (16 Pages) E.C.#95449-095 (09/09/13) KAWNEER COMPANY, INC., 2006 1600 WALL SYSTEM 2 INDEX PAGE PARTS IDENTIFICATION ---------------------------

More information

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

ESTIMATING/TAKE-OFF AND ORDERING GUIDE MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL 1 ESTIMATING/TAKE-OFF AND ORDERING GUIDE 2 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 INDEX PAGE PART IDENTIFICATION ------------------------------------------------------------

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

YOW 250 T Window System

YOW 250 T Window System MegaTherm Glass Fiber With 6/6 Nylon Thermal Break YOW 250 T SYSTEM DESCRIPTION YOW 250 T PERFORMANCE FEATURES 2-1/2 Overall Depth MegaTherm Thermal Break Separate Interior/Exterior Finish Options Variations:

More information

SERIES 5600PG PREGLAZABLE CURTAINWALL

SERIES 5600PG PREGLAZABLE CURTAINWALL SERIES 5600PG PREGLAZABLE CURTAINWALL Part Y56P EFCO 2016 Y56P Page 1 Section Page 1. General notes and Guidelines. 3-4 2. Parts Identification.. 5-8 3. Setting and Anchoring Units.... 9-13 4. Horizontal

More information

SWING DOOR SPECIFICATION

SWING DOOR SPECIFICATION SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

SECTION STAINLESS STEEL WALL PANELS

SECTION STAINLESS STEEL WALL PANELS SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.

More information

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope. SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV

More information

SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM

SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2 TRIM INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0200 GENERAL INSTALLATION NOTES Recommended

More information

KARRIER PANEL - BRICK

KARRIER PANEL - BRICK KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK

More information

Proper Installation of Insulated Metal Wall Panels

Proper Installation of Insulated Metal Wall Panels Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also

More information

Window Installation Instructions Fixed Systems with Subframes

Window Installation Instructions Fixed Systems with Subframes STANDARD PROCEDURE No. I-103 Window Installation Instructions Fixed Systems with Subframes Examined, Accepted and Approved By: D Ray VanNess Title: President SUBJECT: Window Installation Instructions Page

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

Guardian Wall Panel Installation Manual

Guardian Wall Panel Installation Manual Guardian 275 4 Wall Panel Installation Manual Guardian 275 4 Wall Panel Installation Manual This instructional manual provides General Installation Instruction. Installers should refer to the "as-built"

More information

7000 Series Curtain Wall Information Specifications

7000 Series Curtain Wall Information Specifications 7000 Series Curtain Wall Information Specifications Information All framing members shown in this section, unless noted otherwise, are stock items in dark bronze or clear anodic coatings and are available

More information

PART IDENTIFICATION...

PART IDENTIFICATION... 2 1600 WALL SYSTEM 4 INDEX JUNE, 2010 E.C. 95468-36 PAGE PART IDENTIFICATION............................. 3, 4 MATERIAL TAKE-OFF GUIDE....................... 5 PERIMETER DETAILS..............................

More information

Installation Guide Single-Hung, Picture & Shapes Non-Impact & Impact Resistant Florida Flange Windows

Installation Guide Single-Hung, Picture & Shapes Non-Impact & Impact Resistant Florida Flange Windows Non-Impact & Impact Resistant Florida Flange Windows americancraftsmanwindows.com Project Requirements: Read guide before starting installation. Read all warnings and cautions during installation. Check

More information

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262) Rytec Corporation One Cedar Parkway Jackson, WI 53037 1-888-GO-RYTEC (262) 677-9046 WWW.Rytecdoors.com Pharma-Swing Model Number PSW12002 SECTION 08300 HIGH PERFORMANCE FIBERGLASS SWING DOOR PAIR PART

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information Building Codes Structural Sealants Perimeter Sealants Material Handling Cleaning Materials

More information

Thin Brick Façade. Façades Installation Guide

Thin Brick Façade. Façades Installation Guide Thin Brick Façade Façades Installation Guide October 2016 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels. Insulated panels serve as energy efficient,

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

SPECIAL NOTES: EXCLUSIONS: THE FOLLOWING ITEMS ARE NOT SUPPLIED - SEE SEPARATE SAMPLES FOR GLASS MAKE UP.

SPECIAL NOTES: EXCLUSIONS: THE FOLLOWING ITEMS ARE NOT SUPPLIED - SEE SEPARATE SAMPLES FOR GLASS MAKE UP. SPECIAL NOTES: - SEE SEPARATE SAMPLES FOR GLASS MAKE UP. A/C ACCESS CONTROLLED A.F.F. C L B.O.M. DIM. D.L.O. D.L. D.O. EL. F.D. F.F. G.C. ABOVE FINISHED FLOOR BOTTOM OF MULLION CENTER LINE DIMENSION DAYLIGHT

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification

More information

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002 SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall

More information

Window Installation Instructions Hung Window Systems with Receptor Pan

Window Installation Instructions Hung Window Systems with Receptor Pan STANDARD PROCEDURE No. I-110 Window Installation Instructions Hung Window Systems with Receptor Pan Examined, Accepted and Approved By: D Ray VanNess Title: President SUBJECT: Window Installation Instructions

More information

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc. Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT Report Number: C0271.01-450-44 Rendered to: Tubelite Inc. Walker, Michigan MODEL DESIGNATION: 400 Series Curtainwall with 4 Sided SSG PRODUCT

More information

Metafor Panel System Installation Guide

Metafor Panel System Installation Guide Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE

More information

Series B450 Guide Specification

Series B450 Guide Specification Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com STOREFRONT SERIES B450 Shear Block Air Infiltration:

More information

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as

More information

200 / 300 SERIES PANELS COLD STORAGE

200 / 300 SERIES PANELS COLD STORAGE CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES

More information

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE Isoleren Installation Guide ALL INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE Table of Contents

More information

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

ESTIMATING/TAKE-OFF AND ORDERING GUIDE SEPTEMBER, 2017 E.C. 95514-022 1 ESTIMATING/TAKE-OFF AND ORDERING GUIDE 2 INDEX AUGUST, 2017 PAGE PARTS IDENTIFICATION --------------------------- 3,4 MATERIAL TAKE-OFF ------------------------------ 5

More information

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames. SECTION 08410 ALUMINUM ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Aluminum doors and window wall frames. B. Related Sections: 1. Section 08480 Balanced Doors 2. Section

More information

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING

ARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING EXARC Skylights, Inc (800) 247-5934 3793-B North Peachtree Road (770) 451-4352 Chamblee, GA 30341 fax(770) 451-4934 EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING PART 1 GENERAL 1.1 RELATED

More information

SERIES ET350 STRIP WINDOW SYSTEM

SERIES ET350 STRIP WINDOW SYSTEM INSTALLATION INSTRUCTIONS SERIES ET350 STRIP WINDOW SYSTEM Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0297 HANDLING, STORAGE, AND PROTECTION OF ALUMINUM The following

More information

PRODUCT SPECIFICATION SERIES 4500T THERMALLY BROKEN ALUMINUM SLIDING BALCONY DOOR

PRODUCT SPECIFICATION SERIES 4500T THERMALLY BROKEN ALUMINUM SLIDING BALCONY DOOR 08 2 1 SLIDING ALUMINUM FRAMED GLASS DOOR PART 1 - GENERAL A high-quality thermally broken aluminum balcony sliding door designed for residential high rise construction. 1.1 SUMMARY A. Section Includes:

More information

PINNACLE 600/650 HIGH PERFORMANCE CURTAIN WALL apexfacades.com. apexfacades.com 1.2 Pinnacle Pg- 1. Printed on 12/12/17

PINNACLE 600/650 HIGH PERFORMANCE CURTAIN WALL apexfacades.com. apexfacades.com 1.2 Pinnacle Pg- 1. Printed on 12/12/17 1.866.970.5948 apexfacades.com PINNACLE 600/650 apexfacades.com 1.2 Pinnacle Pg- 1 HIGH PERFORMANCE CURTAIN WALL THIS PAGE INTENTIONALY LEFT BLANK apexfacades.com 1.2 Pinnacle Pg- 2 Series Curtain Wall

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels ZINC CENTRIA Concept Series Metal Wall Panels are a versatile design choice for wall cladding panels. They are manufactured with a variety of profiles and five

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL TEchnical bulletin PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION.......................................................................

More information

Designwall 2000/4000. Façades Installation Guide

Designwall 2000/4000. Façades Installation Guide Designwall 2000/4000 Façades Installation Guide July 2017 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels and building envelope solutions. Insulated

More information

Heavy Commercial / Architectural Projected Windows Series L900T AW150

Heavy Commercial / Architectural Projected Windows Series L900T AW150 Heavy Commercial / Architectural Projected Windows Series L900T AW150 Section 08520...Aluminum Windows PART 1: WORK INCLUDED GUIDE SPECIFICATION A. The conditions of the contract and applicable sections

More information

3000 Series Bay/Bow Windows

3000 Series Bay/Bow Windows 3000 Series Bay/Bow Windows 3000 SERIES FIBERGLASS - Min 4 0 3 0 Max 8 0 5 0 Bay picture Bay awning (refer to casement/awning section for maximum vent size) - Min 4 0 3 0 Max 8 0 5 0 (refer to casement/awning

More information

Exterior System installation instructions

Exterior System installation instructions Exterior System installation instructions 11/20/14 WPS ES-400 & 500 INSTALLATION INSTRUCTION. The WPS ES-400 & 500 systems Façade panels are designed for use as an external wall cladding in conjunction

More information

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual Technical Glass Products Architectural Specification Manual 800.426.0279 fireglass.com FIREFRAMES ALUMINUM SERIES INTERIOR APPLICATION ONLY Fireframes Aluminum Series combined with Pilkington Pyrostop

More information

Kingspan Day-Lite Klick

Kingspan Day-Lite Klick Insulated Panel Envelope Systems Roof Wall Façades Lighting Rooftop PV Coldstore Structural Products Cleanrooms UK & Ireland Kingspan Day-Lite Klick Installation Guide Page 2 Accessories Overview Designation

More information

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year. ESR-1015 Issued November 1, 2003 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California

More information

Series 8100 Horizontal Slider HS-C x 1524 ( 71 x 60 )

Series 8100 Horizontal Slider HS-C x 1524 ( 71 x 60 ) 1.01 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract, and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution Insulated Panels North America Universal Barrier Wall Solution 2 Universal Barrier Wall Solution About is a cost effective universal barrier wall alternative solution to traditional multicomponent wall

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM SECTION 07400 TERRA COTTA CLAY TILE RAINSCREEN SYSTEM PART 1 GENERAL 1.01 WORK INCLUDED A. The terra cotta clay tile elements and aluminum support system shall be manufactured by NBK Keramik GmbH as represented

More information

Operable / Fixed Skylight Milgard Aluminum Window

Operable / Fixed Skylight Milgard Aluminum Window Skylight Operable / Fixed Skylight Milgard Aluminum Window The Series Skylight has been specifically designed to provide maximum thermal efficiency by incorporating a special polyurethane barrier between

More information

Window Installation Instructions Series 1000 Steel Replica Window

Window Installation Instructions Series 1000 Steel Replica Window STANDARD PROCEDURE No. I-300 Window Installation Instructions Series 1000 Steel Replica Window Examined, Accepted and Approved By: D. Ray VanNess Title: President SUBJECT: Window Installation Instructions

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing

More information

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window Skylight Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window The Series Skylight has been specifically designed to provide maximum thermal efficiency by incorporating a special polyurethane

More information

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES WINDOW REPLACEMENT GUIDELINES GENERAL 1. Complete and receive approval for WCA s Unit Modification Application for window replacement. 2. Obtain a permit for replacement window installation from the City

More information

MPG Series 2250T Thermally Broken Aluminum Window

MPG Series 2250T Thermally Broken Aluminum Window SECTION 08520 ALUMINUM WINDOWS P a g e 1 MPG Series 2250T Thermally Broken Aluminum Window PART 1 GENERAL 1.01 Work Included A. Furnish and install aluminum architectural windows complete with hardware

More information

Guide Specifications- Section

Guide Specifications- Section Guide Specifications- Section 084113 LaCantina ALUMINUM Folding Door System PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum and glass folding door system with fingertip operation up to 52 wide and 10

More information

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM

More information

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows 3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows 3000 SERIES FIBERGLASS - Min 1 6 2 9 Max 4 0 7 0 - Min 3 0 2 9 Max 8 0 7 0 Double-Hung Double Double-Hung - Min 4 6 2 9 Max 12 0 7 0 Minimum

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

SPECIFICATIONS SECTION 08600

SPECIFICATIONS SECTION 08600 PART 1 GENERAL 1.1 SECTION INCLUDES A. Design, engineering, production drawings, and documents. Detailed design and attachment of metal-framed skylight will be provided as noted in the following specifications.

More information

Model 8000 Double Hung H-C x 2311 (56 x 91 )

Model 8000 Double Hung H-C x 2311 (56 x 91 ) 1.00 GENERAL PROVISIONS: PART 1 - GENERAL A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work with that of all construction contractors

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SECTION DETAILS (MECHANICALLY ASSEMBLY) COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY) SECTION DETAILS (DOOR ASSEMBLY)

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier.

Installation Guidelines for all Quaker products with nail fins New construction nail fin installation with a drainable weather resistant barrier. www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New

More information

SIGNATURE SERIES UNIT WALL

SIGNATURE SERIES UNIT WALL SIGNATURE SERIES UNIT WALL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! 01 TABLE OF CONTENTS SHEET GENERAL INFORMATION Product Use Protection and Storage Check Material

More information

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8 AIR SPACE 3 1 2 SCALE = FULL SIZE Since 906 Series The Series is a heavy triple glazed church window incorporated into a " thermally broken frame. The thermal break is achieved with the use of Thermal Strip technology. Two different aluminum

More information

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR PART 1 - GENERAL 08 13 16 ALUMINUM DOORS (Outswing Aluminum-Framed Glass Doors) A high-quality thermally broken aluminum balcony outswing door designed for residential high rise construction. 1.1 SUMMARY

More information

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM SYSTEM TEN66 INSTALLATION DATA & DETAILS Omnis Panels, Inc. Architectural Building Panels 22 East Chicago Avenue Suite 210 Naperville, Illinois 60540 (800) 450-6099 (630) 355-4040 Fax: (630) 355-4995 www.omnis-panels.com

More information

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used

More information

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8 SLIDING WINDOW PAGE 1 PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have

More information

Model 2000 Single Hung H-HC x 2515 (60 x 99 )

Model 2000 Single Hung H-HC x 2515 (60 x 99 ) Architect to edit the items in red. PART 1 - GENERAL 1.01 GENERAL PROVISIONS: A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. B. Coordinate work

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

3310, 3315, 3310U, 3315U, 3371 & 3371U Picture Windows

3310, 3315, 3310U, 3315U, 3371 & 3371U Picture Windows 3310, 3315, 3310U, 3315U, 3371 & 3371U Picture Windows 3000 SERIES FIBERGLASS - Min 1 0 1 0 Max 8 0 6 0 - Min 2 0 1 0 Max 8 0 6 0 2-lites vertical 2-lites horizontal - Min 1 0 2 0 Max 8 0 6 0 - Min 3 0

More information

Window Installation Instructions: Sliding Window Systems with Frame Master Receptor

Window Installation Instructions: Sliding Window Systems with Frame Master Receptor STANDARD PROCEDURE No. I-181 Window Installation Instructions: Sliding Window Systems with Frame Master Receptor Examined, Accepted and Approved By: D. Ray Van Ness Title: President SUBJECT: Window Installation

More information

200 Singleton Drive Waxahachie, Texas T: F:

200 Singleton Drive Waxahachie, Texas T: F: 200 Singleton Drive Waxahachie, Texas 75165 T: 972-937-9651 F: 972-937-0405 Page 2-D4 United States Aluminum SERIES 4250T AND 4250 CURTAIN WALL TABLE OF CONTENTS PAGE GENERAL NOTES...2-D4 and 3-D4 FRAME

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

SECTION Motor Operated Horizontal Sliding Sound Control Door

SECTION Motor Operated Horizontal Sliding Sound Control Door SECTION 08 34 73 Motor Operated Horizontal Sliding Sound Control Door PART 1 GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of the Contract, including general and Supplementary Conditions

More information

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties

More information

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

apexfacades.com apexfacades.com. Keystone Pg- 1

apexfacades.com apexfacades.com. Keystone Pg- 1 1.866.970.5948 apexfacades.com apexfacades.com K E Y S T O N 1.2E H I G H 5 0 0 P E R F O R M A N C E Keystone Pg- 1 2 C U R T A I NPrintedW A L L on 04/03/18 THIS PAGE INTENTIONALY LEFT BLANK apexfacades.com

More information