OPDISYS Fiber to the Home - Solution

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "OPDISYS Fiber to the Home - Solution"

Transcription

1 OPDISYS Fiber to the Home - Solution

2 Optical distribution system OPDISYS -rack The OPDISYS -rack was specially designed for Fiber-To-The-Home (FTTH) applications. It is a modular system consisting of a basic rack, cable management, mandrel extension racks and gasblocker extension racks and fiber modules. Thanks to its design this system is very flexible. The extension racks can be ordered and combined individually according to the customer s needs. Each fiber module has a front plate with two types of uniform cut-out patterns into which snap-in angled holders fitting into the required adapter type can be inserted. This snap-in angled holder also ensures a 45 degree angle of the adapter is maintained. Each fiber module can be used as a left-side as well as a right-side fiber module. By default, there are protection tubes from the cable clamp to each individual module is installed by kink-resistant PBT-tubes. They ensure that the minimum curve radius of the cable loose tubes from the cable entry to the fiber modules will not be exceeded. The cable clamps are pre-installed either on the top or on the bottom of the rack and are used to secure the strain relief of the incoming cables. They serve further as a fixing point for the cable tubes. Optionally, the strain relief element of the incoming cable to be attached. Technical data: maximum fiber density: 960 fibers at SC, 1920 fibers at LC and E2000 comfortable patching with two-sided overlength patchcord storage optional extensions (for cable guidance and gasblocker integration) available as open and closed rack version removable and rotatable splice/patch fiber module fiber module frontplate with different cutouts and adapter mounting through snap-in angled holder available: SC, LC, E2000 (others on request) optional integration of gas-blockers on incoming tubes possible (on request) colour: RAL 7035, light grey material: Powder coated steel flammability: UL 94V-0 The OPDISYS -rack is the core component of every OPDISYS -system. Both, an open version as well as a closed version, are available. An open version rack is turned into a closed version rack by installing side panels and doors. The rack accommodates the fiber module carrier, the cable entry plates, all types of extension modules and, if a closed version is required, the side panels as well as the front doors. Various fixing sets (see information in the accessories section of this document) are available which allow you to mount the rack to either wall or ceiling or floor. It is possible to mount several racks next to each other back-to-back (requires only floor mounting) or next to each other (requires mounting both to floor and ceiling or wall for stability reasons). A stand-alone Single Row Rack should always be fixed to both floor and ceiling or wall.

3 Rack features: top or bottom cable entry possible top cover provides openings for cables (optionally with brushes) easy expansion with side-by-side or back-to-back mounting of racks solutions for cross-connect and interconnect configurations backside vertical cable guidance for incoming cables bending radius protection of 30mm for fibers and patchcords intelligent patchcord management vertical patchcord cable guidance on left and right side mandrels on left and right side of the rack provide sufficient space for patchcord overlength storage integrated patchcord management to adjacent racks avoids the usage of external ducts Dimensions & capacity - standard version (incl. mandrels) Rack height Rack width Rack weight (open / closed) Max. amount of modules Max. amount of terminations OPDISYS -rack 1000/40HU incl. mandrels, protective tubes OPDISYS -rack 1000/40HU 2200 mm 1000 mm 118 kg / 170 kg 80 Full-Size or 160 Half-Size 960 SC 1920 LC / E2000 Art. No OPDISYS -rack - possible extensions (on request) Gasblocker - extension rack When using blow-in systems, gasblockers are essential in order to protect the installation against gas and/or water entry. The gasblocker extension rack can accommodate the gasblockers. It has a built-in back panel, so no extra back panel is needed in order to turn it into a closed version. Rack doors, side and back panels If a closed rack version is required, doors and panels can be attached to rack. Each door has an opening angle of 180. The doors are equipped with an integrated lever and lock and have an A4 document holder on their inner side. Each side panel is useable for right as well as for left side mounting. Gasblocker - extension rack on request Panels / door set Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 3

4 OPDISYS -rack - accessories Fixing sets Several fixing sets are available to mount the rack to the wall, on the floor or to mount multiple racks side by side or back to back to each other. Each individual fixing set contains all necessary screws, mounting brackets, washers and anchor pins. Tool kit adapter holder pincer The adapter holder pincer is designed to easily remove the snap-in angled holder from the frontplate cutout of the OPDISYS fiber module. Thanks to its small and compact design it ensures the smooth removal of a snap-in angled holder without interfering with other connections. torx socket wrench draw wire or element The draw wire or element tool is necessary to insert the incoming fiber cable into the fiber protection tube which is fed up to the fiber optic module. This tool is required to install a OPDISYS -System. Fixing set, back-to-back or side-to-side Art. No Fixing set for double bottoms Art. No Fixing set base with leveling feet Art. No Tool kit Art. No OPDISYS -fiber modules The multi-circuit management fiber modules are used as combined splice & patch modules. They offer highest fiber density along with best maintainability. Maximum flexibility is guaranteed by metal frontplates and 45 angled adapter holders for all conventional adapter types. The fiber modules are available as full-size fiber modules with a height of 1HU. Fiber modules can be equipped with different adapter types or with a closed frontplate without adapters for a splice-through version (in this case, a loop- back connection of fibers can be done via splices). The material of the LSZH fiber modules is a Polycarbonate / ABS blend. The symmetrical design of the multi-circuit management fiber modules allows you to use the same module for left- and right-side mounting. A uniform module colour optimizes stock keeping, while individual threefold colour code labelling (on front, side and cover) provides fast and clear module and fiber identification. On request we can deliver each fiber module with a customized labelling of the top cover (index of all ports with description) as well as a labelling of the side of each Fiber Module (indication of the street and the building this module is assigned to) according to the customer s request. Also the labelling of the fiber module numbering can be done by us. fiber modules can be rotated by 90 and are removable from the rack incoming fibers and pigtails are stored in separate areas easy to snap in adapter holders allow comfortable cleaning of pigtail-connector ferrules by taking off the adapter holders. identical splice protection holder for both shrink and crimp splice protection two-sided, easy to remove transparent covers per fiber module bending radius protection for all fibers and pigtails overlength storage of incoming cable subtube is possible on the bottom side of the module Technical Data: Colour RAL 7035, light grey Material Powder coated steel Flammability UL 94V-0 Weight (full size module) 145 grams (without adapters and pigtails) Each Fiber Module is equipped with a frontplate, snap-in angled holders, rubber shrink/crimp splice protection holder, fiber protection pipe holder, two transparent covers, designation label, door latch and inserted adapters and pigtails.

5 Plug-in configuration - fully equipped SC LC E2000 Amount of adapters Amount of pigtails Max. amount of spices Heat shrink splice protection* Crimp splice protection* Max. amount of spices * Heat shrink splice protection or crimp splice protection are not included and must be ordered separately. Fiber module 24 LC/APC, 1HU Art. No Fiber module 24 E2000/APC, 1HU Art. No Fiber module 12 SC/APC, 1HU Art. No Fiber module for up to 48 splices, 1HU Art. No Cable clamp set Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 5

6 Patch cable PC LC/APC simplex, 2 mm Characteristics of LC/APC simplex: user-friendly audible latch to indicate proper mating push-pull locking plastic housing with zirconia ferrule standard IEC insertion loss (IL) for SM (typical) average value <0.15 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) strain relief 100 N PC LC/APC simplex 3 m Art. No PC LC/APC simplex 5 m Art. No PC LC/APC simplex 10 m Art. No PC E2000/APC simplex, 2 mm Characteristics of E2000/APC simplex: locks with locking lever automatic dust protection flap plastic housing with zirconia ferrule standard IEC insertion loss (IL) average value <0.10 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) PC E2000/APC simplex 3 m Art. No PC E2000/APC simplex 5 m Art. No PC E2000/APC simplex 10 m Art. No PC SC/APC simplex, 2 mm The patch cables consist of an inhouse cable with 2 mm outer diameter and is pre-assembled with two connectors. They are used to establish a connection between patch panels / cabinets or terminals. Because of their mechanical stability, patch cables can be used in cabinets, enclosures and with some restrictions in cable ducts. However, they may not be drawn in or injected. Characteristics of SC/APC simplex: automatic lock in adapter unlocks by pulling on housing ( push-pull ) plastic housing with zirconia ferrule standard IEC insertion loss (IL) (typical) average value <0.20 db (to reference connector) maximum value <0.30 db (to reference connector) return loss (RL) >65 db 8 polishing (APC-polishing) PC SC/APC simplex 3 m Art. No PC SC/APC simplex 5 m Art. No PC SC/APC simplex 10 m Art. No

7 Fiber optic cable A-DQ(BN)2Y CT - Outdoor cable, center unitube, D35-S15 outdoor cable rodent protection metal-free longitudinally water-tight A-DQ(BN)2Y CT 12E9/125 Art. No A-DQ(BN)2Y CT 24E9/125 Art. No Type number of numbers of tube-ø tenisle strength outer-ø weight fibers / tube fibers approx. mm max. N approx. mm approx. kg/km A-DQ(BN)2Y CT 12E9/ , ,5 72,8 A-DQ(BN)2Y CT 24E9/ , ,5 73,7 Central loose tube cable for outdoor applications. Rodent protected by glass rovings. This cable is used as low fiber count data cable in distribution networks and meets the demands of outdoor environments. Fibers according ITU-T G.652.D Construction center unitube strength members (aramide yarns) PE-sheath, UV-resistant, black with two orange longitudinal stripes Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colour red Laying usable for fixed laying in ducts or conduits and outdoors Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: torsion: kink, cable: kink, tube: min. bending radius: temperature range: water penetration: according to IEC E1 according to IEC E3 value: 3000 N/10 cm according to IEC E4 value: 5 Nm according to IEC E7 value: 5 cycles ±1 turn according to IEC E10 value: The cables do not form a kink when a loop is drawn together to a diameter of 100 mm. according to IEC E16 value: The loose tubes do not kink. according to IEC E11 value: R = 20 x D (cable outer diameter) according to IEC F1 storage and transport: -40 C up to +70 C laying: -5 C up to +60 C operation: -25 C up to +70 C according to IEC F5 value: No water on free end. OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 7

8 A-DQ(BN)2Y GGT - Outdoor cable, loose tube construction, D23-S20 outdoor cable rodent protection metal-free longitudinally water-tight A-DQ(BN)2Y GGT 2x12E9/125 Art. No A-DQ(BN)2Y GGT 4x12E9/125 Art. No A-DQ(BN)2Y GGT 6x12E9/125 Art. No A-DQ(BN)2Y GGT 8x12E9/125 Art. No A-DQ(BN)2Y GGT 10x12E9/125 Art. No A-DQ(BN)2Y GGT 12x12E9/125 Art. No A-DQ(BN)2Y GGT 8x24 E9/125 Art. No A-DQ(BN)2Y GGT 18x24E9/125 Art. No Type number of number of tubes number of tube-ø tensile strength outer-ø weight fibers/tube + fillers fibers approx. mm max. N approx. mm approx. kg/km A-DQ(BN)2Y GGT 2x12E9/ , ,2 141,7 A-DQ(BN)2Y GGT 4x12E9/ , ,2 145,3 A-DQ(BN)2Y GGT 6x12E9/ , ,5 160,0 A-DQ(BN)2Y GGT 8x12E9/ , ,8 182,5 A-DQ(BN)2Y GGT 10x12E9/ , ,3 214,0 A-DQ(BN)2Y GGT 12x12E9/ , ,0 251,0 A-DQ(BN)2Y GGT 8x24E9/ , ,5 221,8 A-DQ(BN)2Y GGT 18x24E9/ , ,5 335,4 Stranded loose tube cable for outdoor applications. Highly rodent protected by 2 layers of glass rovings. This cable is used as higher fiber count data cable in distribution networks and withstands environments with high mechanical demands. Fibers according ITU-T G.652.D Construction FRP-central element loose tubes, SZ-cabling (if necessary with fillers) dry filled cable core strength members (glass-rovings) ripcord PE-sheath, UV-resistant, black with two orange longitudinal stripes Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colours 1: red 2: green others: nature or white Filler colours black Laying usable for fixed laying in ducts or conduits and outdoors Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: torsion: kink, cable: kink, loose tube: min. bending radius: temperature range: water penetration: according to IEC E1 according to IEC E3 value: 3000 N/10 cm according to IEC E4 value: 10 Nm according to IEC E7 value: 5 cycles ±1 turn according to IEC E10 value: The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter. according to IEC E16 value: The loose tubes do not kink. according to IEC E11 value: R = 20 x D (cable outer diameter) according to IEC F1 storage and transport: -40 C up to +70 C laying: -5 C up to +60 C operation: -30 C up to +70 C according to IEC F5 value: No water on free end.

9 A-DQ(ZN)2Y Mini T - Mini cable, loose tube construction, D15-S05 outdoor cable metal-free longitudinally water-tight A-DQ(ZN)2Y Mini T 2x12E9/125 blue Art. No A-DQ(ZN)2Y Mini T 4x12E9/125 red Art. No A-DQ(ZN)2Y Mini T 6x12E9/125 violet Art. No A-DQ(ZN)2Y Mini T 8x12E9/125 pink Art. No A-DQ(ZN)2Y Mini T 12x12E9/125 grey Art. No Type number of number of tubes tube-ø tensile strength outer-ø weight fibers + fillers approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y Mini T 2x12E9/125 blue , ,6 29,1 A-DQ(ZN)2Y Mini T 4x12E9/125 red , ,6 30,0 A-DQ(ZN)2Y Mini T 6x12E9/125 violet , ,6 30,8 A-DQ(ZN)2Y Mini T 8x12E9/125 pink , ,5 44,5 A-DQ(ZN)2Y Mini T 12x12E9/125 grey , ,5 64,1 Stranded mini tube cable for laying into micro ducts. This cable is used in access networks as both connection between fiber distributers and house connection for multi dwelling units. Fibers according ITU-T G.657.A1. Due to both the deployed fibers and its light construction it is suitable for small bending radii. Construction central member, metal free loose buffer tube filled with a thixotropic gel, swellable aramid yarns dry filled cable core rip cord PE-sheath Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise Tube colours 1: red 2: green others: nature or white Filler colours black Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: according to IEC E1 compressive strength: according to IEC E3 value: 1000 N/10 cm impact strength: according to IEC E4 value: 5 Nm (3 impacts, 300 mm hammer radius) min. bending radius: according to IEC E11 values: static R = 10 x D, dynamic R = 20 x D (cable outer diameter) temperature range: according to IEC F1 storage and transport -30 C up to +60 C laying -5 C up to +50 C operation -30 C up to +60 C water penetration: according to IEC F5 value: 1 m (0,1 bar, 24 h) OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 9

10 A-DQ(ZN)2Y Mini CT - Mini cable, central unitube, D30-S04 outdoor cable metal-free longitudinally water-tight A-DQ(ZN)2Y Mini CT 12E9/125 yellow Art. No A-DQ(ZN)2Y Mini CT 24E9/125 blue Art. No Type number of number of tube-ø Zugfestigkeit outer-ø weight fibers/tube fibers approx. mm max. N approx. mm approx. kg/km A-DQ(ZN)2Y Mini CT 12E9/125 yellow , ,9 12,9 A-DQ(ZN)2Y Mini CT 24E9/125 blue , ,9 13,8 Central mini tube cable for laying into micro ducts. This cable is used in access networks as drop cable to house connections. Fibers according ITU-T G.657.A1. Due to both the deployed fibers and its light construction it is suitable for small bending radii. Construction center unitube strength members (aramide yarns) PE-sheath Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colour red Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: min. bending radius: temperature range: according to IEC E1 according to IEC E3 value: 1000 N/10 cm according to IEC E4 value: 1 Nm (3 impacts, 300 mm Hammer radius) according to IEC E11 value: static R = 20 x D (cable outer diameter) according to IEC F1 storage and transport -30 C up to +70 C laying -5 C up to +50 C operation -20 C up to +70 C

11 I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable - Inhouse cable, V06 inhouse cable metal-free halogenfree, flame retardant I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable Art. No Type number of tube-ø number of tubes tensile strength *) outer-ø weight fibers approx. µm + fillers max. N approx. mm approx. kg/km I-VQ(ZN)H 4E9/125 FTTH-Inhouse cable ,5 *) with reversible attenuation increase FTTH in-house cable, suitable for laying within buildings in both horizontal and vertical ways. This cable is suitable for direct assembling with connectors. Fibers according ITU-T G.657.A1. Construction 4 buffered fibers (silikon-coated, 600 microns) strength members (aramide yarns) FRNC-sheath according to IEC , UV-resistant Fiber colours red, green, yellow, blue Mantelfarbe grey Marking letter symbol of fiber type, meter marking, PENGG KABEL, year of manufacturing Technical Data standard: IEC tensile strength: according to IEC E1 compressive strength: according to IEC E3 value: 500 N/10 cm bending radius: static 15 x cable outer diameter dynamic 20 x cable outer diameter temperature range: storage and transport -25 C up to +70 C laying -5 C up to +50 C operation -5 C up to +50 C OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 11

12 Fiber optic enclosure SEC15 for max. 128 splices Description The SEC15 dome enclosure is particularly suitable for connecting fibre optic cables featuring a small number of fibres Enclosure for in-line connections and branch-offs Suitable for underground, duct, wall and pole/tower mounting Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement Storage of cut/uncut multi-fibre loose tubes Cable entries for max. 1 oval entry for 2x10-25 mm cables 3 entries for mm cables Splice cassettes (order separate) 8 x SK120S Degree of protection >IP68 Max. splice capacity Splice protection tube 128 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at the centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg Steel ball, 2 m fall, at the centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <240 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 2 kg Scope of delivery Base plate, dome, locking ring incl. snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation SEC15 for max. 128 splices Art. No

13 SEC23 Tubeless short for max. 288 / 432 splices Description Tubeless version suitable especially for Single Circuit (SC) and Single Element (SE). Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Tubeless laying of the fibres from entry to splice cassette In-line connection and branch-off enclosure Suitable for ground, duct, wall, pole and tower mounting Short version especially for manholes or cable ducts Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement An entry module permits fibre guidance to any desired cassette entry Cable entries for max. 1 oval entry for 2x10-25 mm cables 4 entries for mm cables 2 entries for mm cables Splice cassettes (order separate) 36 x SK123 (SE) or SK223 (SC) Available in cassette sets of 6 splice cassettes each max. 6 sets (3 units on either side). Splice cassettes engaged in a slanted position Pivoting splice cassettes (90 ) to provide easy access to each splice Degree of protection >IP68 Max. splice capacity 2x4 splices at each SK223 (SC) splices at each SK123 (SE) 432 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg steel ball, 2 m fall, centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <600 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 3.5 kg Scope of delivery Base plate, dome, locking ring with snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation, 2 entry modules incl. cover SEC23 Tubeless short for max. 288 / 432 splices Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 13

14 SEC23 Tubeless classic for max. 576 / 864 splices Description Tubeless version suitable especially for Single Circuit (SC) and Single Element (SE). Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Tubeless laying of the fibres from entry to splice cassette In-line connection and branch-off enclosure Suitable for ground, duct, wall, pole and tower mounting Suitable for uncut cables Assembly/disassembly of the dome without any tools Sealings can be used again Separate strain relief points for central strength member and Kevlar reinforcement An entry module permits fibre guidance to any desired cassette entry Cable entries for max. 1 oval entry for 2x10-25 mm cables 4 entries for mm cables 2 entries for mm cables Splice cassettes (order separate) 72 x SK123 (SE) or SK223 (SC) Available in cassette sets of 6 splice cassettes each ½ max. 12 sets (6 units on either side). Splice cassettes engaged in a slanted position Pivoting splice cassettes (90 ) to provide easy access to each splice Degree of protection >IP68 Max. splice capacity 2x4 splices at each SK223 (SC) splices at each SK123 (SE) 864 Tests according to DIN Draft 4/97 Mechanical strength Load (15 min) 1000 N at centre of the enclosure, contact area 5 cm 2 Impact (once) 1 kg steel ball, 2 m fall, centre of the enclosure Pressure resistance Permanent pressure 0.4 bar above atmospheric Tight from -40 C to +70C Tightness with cable Strain (15 min) 1000 N Shearing/bending (twice) Deflection 45 or a max. of 500 N bending force, Point of application 250 mm from cable entry Torsion (twice) ±90 rotation angle or a max. torque of 50 Nm, Point of application 500 mm from cable entry Vibration 168 hours; both cable ends fastened, Amplitude ±3 mm, frequency 10 Hz Temperature changes -40 C to +70 C, 10 times Immersion in wetting agent 168 hours External pressure resistance 4 m water column Water vapour permeation <600 µg/h at 10 C Material Base plate, dome, locking ring and snap-in lock Environmentally friendly, UV-resistant polypropylene Strain relief angle Stainless steel Cassette support Powder-coated aluminium sheet, RAL 7035 Weight approx. 4 kg Scope of delivery Base plate, dome, locking ring with snap-in lock, securing pin, sealing ring, cassette support, drying agent, instruction for installation, 2 entry modules incl. cover SEC23 Tubeless classic for max. 576 / 864 splices Art. No

15 Fiber optic enclosures - accessories Cable entry sets (shrinking) Sealing set for standard connection bushes of the SEC 15 and SEC 23 versions For sealing cables with a PE-jacket Excellent tightness and mechanical strength Material: Cross-linked polyolefine, inside coated with thermoplastic adhesive Scope of delivery: Heat-shrinkable sleeve, emery cloth, cable cleaning cloth, cable tie wraps, installation material; 1 additional branch-off clamp coming with the oval cable entry set Oval cable entry set 2x10-20 mm Art. No Round cable entry set mm Art. No Round cable entry set mm Art. No Microtube entries As an alternative to the shrinking entries there are microduct launches 16/12 mm 14/10 mm, 12/8 mm available on request. Microtube entries on request Splice cassette SK120 á 16 splices Stripping dimensions (cm): Windings Min. Max With the possibility for mounting the hinge: Splice storage for all kinds of optical fibres Splice cassettes can be piled one on top of the other With or without the possibility for mounting the hinge Installation of different splice protection holders is possible through the snap-on system Laying in an 8-shaped loop is possible Bending radius: >30 mm Capacity Splices 16 splice protection tubes Ø 2.5 mm (heat-shrinkable) Splice protection holders 2x...-SRH8 Reserve fibre length approx. 40 m Material: Polystyrene Weight: 36 g Scope of delivery: 1 Splice cassette (excl. splice protection holder, excl. hinge) Without the possibility for mounting the hinge: Splice cassette SK120 á 16 splices Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 15

16 Splice cassette set SK123 6xSE á 12 splices The splice cassette set serves for guiding fibres from the entry module to the splice cassette and for splice storage of all kinds of optical fibres Installation of max. 6 splice cassette sets in the SEC23 Tubeless short enclosure and max. 12 splice cassette sets in the SEC23 Tubeless classic enclosure Cassette base plate with guiding channels for fibres and fastening options for a max. of 6 splice cassettes LWL-SK123 (SE) Versions for heat-shrinkable (splice protection tubes) Material: Polycarbonate VL94HB, colour RAL 9001 Weight: 0,3 kg Scope of delivery: 1 cassette base plate, 6 LWL-SK123 splice cassettes Splice cassette set SK123 6xSE á 12 splices Art. No Splice cassette set SK223 6xSC á 2x4 splices The splice cassette set serves for guiding fibres from the entry module to the splice cassette and for splice storage of all kinds of optical fibres Installation of max. 6 splice cassette sets in the SEC23 Tubeless short enclosure and max. 12 splice cassette sets in the SEC23 Tubeless classic enclosure Cassette base plate with guiding channels for fibres and fastening options for a max. of 6 splice cassettes LWL-SK223 (SC) Versions for heat-shrinkable (splice protection tubes) Material: Polycarbonate VL94HB, colour RAL 9001 Weight: 0,47 kg Scope of delivery: 1 cassette base plate, 6 LWL-SK223 splice cassettes Splice cassette set SK223 6xSC á 2x4 splices Art. No Wall-mounting set for SEC15, SEC23 Fastening angle for convenient wall-mounting Material: Powder-coated 3-mm aluminium sheet, RAL 7035 Scope of delivery: Wall-mounting set SEC23 SEC15 SEC23 Short Wall-mounting set for SEC 15 Art. No Wall-mounting set for SEC 23 Art. No

17 Outdoor cabinet KVZ F5 1080/320 OPDISYS Technical characteristics: Material housing and base polycarbonate Color housing and base RAL 7038 Protection class IP54 Capacity of fiber modules 16 OPDISYS Modules (16HU) at a housing size (WxHxD) 998 x 754 x 310 Gas blocker permanently integrated Door with swivel handle, prepared for two half profile cylinder Fiber optic fixing kit made of stainless steel KVZ F5 1080/320 OPDISYS Art. No Fiber module 24 LC/APC, 1HU Art. No Fiber module 24 E2000/APC, 1HU Art. No Fiber module 12 SC/APC, 1HU Art. No Fiber module for up to 48 splices, 1HU Art. No KVZ small as splicing version - equipped with 2x6 splice cassettes sets of SEC23 on request OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 17

18 Cable manhole EK 428 LW 800x1400 Low weight An advantage when transporting and handling. Easy delivery to inaccessible sites, such as along railway lines or inner-city areas Minimal installation effort No heavy transporters or cranes required Modular construction Manhole depths and connection positions are variable by means of the combination of framework modules Superstructure about existing pipe extrusion lines Without any difficulty bonding of existing pipeline alignment through open side parts in connection with the accessory Through the low weight the bonding is acutely easy Practical product Infinitely variable height and angle compensation Exact-fit pipe connections by means of set break points Sealing elements for cables without tubing Stability High degree of stability with low inherent weight, resulting from the use of high-quality plastic Optimum embedding in the surrounding soil Mechanical protection of the top edge provided by hot-dip galvanised steel frame Material For all load-bearing elements made of plastic: Modified polycarbonate (PC) High temperature resistance Surface finish not critical affected by hot or melted asphalt High degree of stability Fireproof Corrosion-proof Highly resistant to chemicals Highly resistant to UV light and weathering Recyclable several times over

19 Fittings Up to 2 sleeves (SEC15 or SEC23) for direct buried fiber optic cables or micro tubes with swiveling telescopic sleeve holder for a optimum working position Manhole cover Manhole cover in various versions: Cast iron (with lock) - D400 (400 kn testing force) Steel filled with concrete (with lock) - D400 (400 kn testing force) Bulb plate (with screwed) - A15 (15 kn testing force) Accessories Under cover fuse for protection against damage to the fittings Monitoring system for central monitoring of access Dimensions and test classes clear dimension: 800 x 1400 mm External height: 935 mm Test class: D400 and A15 EK 428 LW 800x1400 with cast iron cover (consisting of 4 parts) Art. No EK 428 LW 800x1400 with bulb plate cover (consisting of 3 parts) Art. No EK 428 LW 800x1400 with steel cover on request Telescopic sleeve holder Art. No Other manhole types on request OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 19

20 House lead-in EK 459 for micro-tubes, gas-tight This house lead is specially designed for the sealing of fiber optic cable in the introduction in building walls. It is suitable for all wall types (DIN 1819T.4) as suitable for foundations made of waterproof concrete. The foaming principle guarantees a perfect seal. Technical characteristics: Required bore diameter of only 40 mm Cover a large range of diameters of m micro-tubes: 7-14 mm single introduction and 7 mm double insertion Wall thickness: 400 mm standard, others upon request Delivery option for micro-tube diameters from 2 to 8 mm Gas-tight and waterproof up to 4 m water column Due to funnel-shaped silicone sealing discs technology only minimum effort pushing in the micro-tube / fiber optic cable, therefore no risk of kinking the line About quick-grid-screw flange permanent pressing of the plastic sealing bead (outside of building) Fast and gentle on the material sealing the micro-tubes / fiber optic cables EK 459 for micro-tubes, gas-tight, for wall thicknesses up to 400 mm Art. No Other house lead-in on request

21 Microtube Micro tubes are made of high density polyethylene (HDPE) and Silicore (super smooth inner surface, co-extruded with HDPE, allows higher injection and retraction speeds and lengths) were prepared and used to protect optical fiber cable. Inner surface is made from permanent sliding material Silicore with a very low coefficient of friction and standardly with fine ribs. Outer microduct s surface is smooth. Microduct is not designed for permanent inner pressure. Microduct does not contain dangerous chemicals in accordance to the Directive 2006/1907/EC (REACH). Microduct meets requirements of the Directive 2002/95/EC (RoHS) - content of lead, cadmium, mercury, Cr VI, PBB und PBDE. General specification Parameter Value Standard, conditions Ovality max. 5% Internal standard, before coiling Inner coefficient of friction max. 0,1 Internal standard Visual examination free from defects Internal standard Crush - pressure force min N EN , E3, sample 200 mm, aktive 100 mm, ID deformation by 15%, speed 3 mm/min. Impact no damage after the test, dimens. in tolerances after recovery EN , method E4, striking surface radius 10 mm, impact energy 15 J, recovery time 1 h Thermal expansion 1, K 1 ISO , temperature range from -20 C to +70 C Longitudinal reversion max. 3% EN ISO 2505, oven, 110 C, 60 min. Transport and storage temperatures from -40 C to +70 C - Installation temperatures from -10 C to +50 C - Operating temperatures from -40 C to +70 C - Blowing pressure max. 20 bar max. 2 hours at max. +50 C Outdoor exposure (central eurpope conditions) max. 12 months - Microduct DB 7/4 - recommended cable outer diameter from 1,0 to 2,5 mm Parameter Value Standard, conditions Outer diameter (OD) 7±0,1 mm Internal standard Inner diameter (ID) min. 3,9 mm Internal standard Wall thickness (WT) min. 1,4 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 3,5 mm Burst pressure min. 70 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,1 mm EN , E3, sample 200 mm, aktive 100 mm, force 1718 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,04 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 4,7 - Weight 25 kg/km - Installation tensile force max. 350 N - Minimum bending 70 mm - OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 21

22 Microduct DB 10/6 - recommended cable outer diameter from 2,0 to 4,5 mm Parameter Value Standard, conditions Outer diameter (OD) 10±0,1 mm Internal standard Inner diameter (ID) min. 5,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 5,0 mm Burst pressure min. 70 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,5 mm EN , E3, sample 200 mm, aktive 100 mm, force 2100 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,19 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 5 - Weight 47,5 kg/km - Installation tensile force max. 680 N - Minimum bending 100 mm - Microduct DB 12/8 - recommended cable outer diameter from 4,0 to 6,5 mm Parameter Value Standard, conditions Outer diameter (OD) 12±0,1 mm Internal standard Inner diameter (ID) min. 7,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 6,5 mm Burst pressure min. 60 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 1,8 mm EN , E3, sample 200 mm, aktive 100 mm, force 1680 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,36 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 6 - Weight 59 kg/km - Installation tensile force max. 840 N - Minimum bending 120 mm - Microduct DB 14/10 - recommended cable outer diameter from 5,0 to 8,5 mm Parameter Value Standard, conditions Outer diameter (OD) 14±0,1 mm Internal standard Inner diameter (ID) min. 9,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 8,0 mm Burst pressure min. 50 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 2,1 mm EN , E3, sample 200 mm, aktive 100 mm, force 1400 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,61 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 7 - Weight 72 kg/km - Installation tensile force max N - Minimum bending 140 mm - Microduct DB 16/12 - recommended cable outer diameter from 7,0 to 10,0 mm Parameter Value Standard, conditions Outer diameter (OD) 16±0,1 mm Internal standard Inner diameter (ID) min. 11,9 mm Internal standard Wall thickness (WT) min. 1,9 mm Internal standard Blown ball test (BB-test) pass Internal standard, ball diameter 10,0 mm Burst pressure min. 40 bar EN ISO , 2 Crush - residual deformation max. 15% OD = max. 2,4 mm EN , E3, sample 200 mm, aktive 100 mm, force 1200 N, 3 mm/min., aktion 60 s, recovery 20 s Bending stiffness min. 0,94 N.m 2 Internal standard Standard Dimension Ratio (SDR = OD/WT) 8 - Weight 84 kg/km - Installation tensile force max N - Minimum bending 160 mm - Microduct 7/4 (for cables from 1,0-2,5 mm) Art. No Microduct 10/6 (for cables from 2,0-4,5 mm) Art. No Microduct 12/8 (for cables from 4,0-6,5 mm) Art. No Microduct 14/10 (for cables from 5,0-8,5 mm) Art. No Microduct 16/12 (for cables from 7,0-10,0 mm) Art. No

23 Metal free micro duct connector Body material: Polyamide Spring material: Polyacetal Seal material: NBR Temperature range: -20 C to +50 C Working pressure: max. 20 bar Lifespan: 25 years Standards: EN Available sizes (Dimension length / width / through bore / tensile force [N]) Connector for microducts 7/3.5 mm 42 / 17 / 3.5 / 150 N Connector for microducts 10/5.5 mm 48 / 20.5 / 5.5 / 250 N Connector for microducts 12/8 mm 52 / 23 / 8.0 / 530 N Connector for microducts 14/10 mm 60 / 25.5 / 10.0 / 1000 N Connector for microducts 16/12 mm 67 / 30 /12.0 / 1500 N Metal free micro duct connector 7 mm Art. No Metal free micro duct connector 10 mm Art. No Metal free micro duct connector 12 mm Art. No Metal free micro duct connector 14 mm Art. No Metal free micro duct connector 16 mm Art. No Metal free end stop Body material: Polyamide Spring material: Polyacetal Seal material: NBR Temperature range: -20 C to +50 C Impact resistance: N Working pressure: max. 20 bar Lifespan: 25 years Standards: EN Available sizes (Dimension length / width / tensile force [N]) End stop for 7 mm microducts 23 / 17.0 / 80 N End stop for 10 mm microducts 26 / 20.5 / 150 N End stop for 12 mm microducts 28 / 23.0 / 200 N End stop for 14 mm microducts 33 / 25.5 / 300 N End stop for 16 mm microducts 36.5 / 30.0 / 400N Metal free micro duct end stop 7 mm Art. No Metal free micro duct end stop 10 mm Art. No Metal free micro duct end stop 12 mm Art. No Metal free micro duct end stop 14 mm Art. No Metal free micro duct end stop 16 mm Art. No Divisible gasblock Body material: Seal material: Gas seal pressure: reinforced glassfiber polyamid TPE 0,5 bar Divisible gasblock 7 (for 2,5 mm cables) Divisible gasblock 10 (for cables from 2,5-3,9 mm) Divisible gasblock 12 (for cables from 5,6-6,5 mm) Divisible gasblock 14 (for 8,5 mm cable) Divisible gasblock 16 (for 8,5 mm cable) Art. No Art. No Art. No Art. No Art. No Microduct cutter and deburring tool For clean and safe construction of the microduct network, we recommend that you use the appropriate tools: Microduct cutter 4-12 mm Microduct shear 4-28 mm Deburring tool Microduct shear 4-28 mm Art. No Microduct cutter 4-12 mm Art. No Deburring tool Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 23

24 Interconnect case OM10 BEP The distribution enclosure serves as a termination for fiber optic cable to connector and for storing from splicing for max. 8 customers fibers (1 household) Small termination box, especially suitable where space is limited Suitable for indoor wall-mounting and installation in moist rooms Pull-out splice storage frame with splice protection holders Installation point for strain relief element (Kevlar) Provides sufficient space for multi-fibre loose tube reserves under the splice storage frame Entries Multi entry for 3 x I-VQ(ZN)H cable and PG9 cable gland Splice protection holder 1 SRH8 or 1 SWH12 Degree of protection of the empty enclosure IP54 Material Enclosure Polystyrene, similar to RAL 7035 Splice storage frame Powder-coated aluminium, RAL 7035 PG Cable entry gland Plastic Weight Approx. 0.7 kg Scope of delivery 1 Enclosure, 1 splice storage frame, 1 copy of Instructions for Installation, 1 PG9-cable gland, 2 cable tie wraps, 2 pigtail clips PC121, 1 SRH8/SWH12 splice protection holder OM10 BEP for max. 8 customer fibers (1 household), incl. 1 Stk. splice storage frame Art. No

25 RGV20 BEP The interconnect case RGV 20 BEP is used for distribution of the fibers in multiple dwellings to the specific house cabling for max. 96 customer fibers. The tubeless version is particularly suitable for Single Circuit (SC) and Single Element (SE) Single Circuit: Distribution of the fibres from one multi-fibre loose tube to several splice cassettes through fibre guiding channels Single Element: For multi-fibre loose tube management (multi-fibre loose tube upon multi-fibre loose tube) Tubeless laying of fibres from the entry to the splice cassette Enclosure for in-line connections and branch-offs Suitable for wall mounting Door is right-hinged and easy to remove Clip-down handle Door sealing inside Degree of protection IP 54 with PG cable entry Strain relief points for central strength member and Kevlar reinforcement Storage area for cut/uncut multi-fibre loose tubes The removable cassette-ground plate is used for fastening the multi-fibre loose tubes and also for assembling the splice cassette sets onto the mounting plate The entry module permits fibre routing to any cassette entry Cable entries PG cable entries Ø 8-10 mm (PG11) Ø mm (PG13) Ø mm (PG16) Ø mm (PG21) 24x Ø 3 mm (PG29) for I-VQ(ZN)H 12 x SK123 (SE) or SK223 (SC) Splice cassettes Available as sets of 6 splice cassettes each => max. 2 sets Splice cassettes are engaged in a slanted position Swing-type splice cassettes (90 ) provide easy access to each splice Permanent temperature Max. 150 C Material Enclosure Thermoformed, self-extinguishing, halogen-free, glass-fibre reinforced polyester, colour RAL 7035 Mounting-, Base plate Powder-coated sheet steel, RAL 7035 Patch-, Fastening angle Powder-coated sheet steel, RAL 7011 Weight Approx. 5,1 kg Scope of delivery 1 Cabinet incl. door, clip-down handle and sealing, 1 mounting plate, 1 base plate, 1 entry module with cover, 1 fastening angle, 1 Angle with holes, fastening screws 415 A 315 B 175 C RGV20 BEP basic casing empty Art. No RGV20 BEP for max. 48 customer fibers (11 households), incl. 1 splice cassettes set (see page 16) RGV20 BEP for max. 96 customer fibers (23 households), incl. 2 splice cassettes sets (see page 16) Art. No Art. No OTO ZT 2xLC/APC Fiber optic junction box for FTTH-inhouse cabling For surface wall mounting FTTH junction box for 1 to 4 fibers Consists of a metal mounting plate, a plastic housing with integrated fiber storage for cable and pigtail wires and integrated in the housing Shuttered 2x LC / APC adapters including pigtails Adapters with integrated laser protection Labeling field with transparent cover Color: white, similar to RAL 9010 Dimensions: 88x88x23 mm OTO ZT 2xLC/APC pigtails inserted - ready for splicing Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 25

26 Heat shrinkable fiber optic splice protector Outer shrink tube: transparent, both ends preshrunk to closing the gap between the two tubes Inner shrink tube: transparent EVA hot melt adhesive (Ethylene vinyl acetate) Stainless steel with rounded ends to avoid fiber damage Color transparent Operating temperature -45 C to +100 C Shrink temperature 110 C Tensile strength 18 MPa (acc. ASTM D2671) Ultimate elongation 700 % (acc. ASTM D2671) Density 0,94 g/cm3 (acc. ISO R1183D) Dielectric strength 25 kv/mm (acc. IEC 243) Dielectric constant 2,5 (acc. IEC 243) Longitudinal change ±5 % (acc. ASTM D2671) Marking Pengg_MM.JJJJ Type Outer shrink tube (shrunk) outer-ø D1 length L1 Inner shrink tube (unshrunk) outer-ø D2 length L2 pin-ø D3 Steel pin stainless length L3 SP/F25/2,5A 2,45 ±0,1mm 25 ±0,5mm 1,3 ±0,3mm 25 ±0,5mm 1,0 ±0,05mm 21 ±0,1mm SP/F45/2,5A 2,45 ±0,1mm 45 ±0,5mm 1,3 ±0,3mm 45 ±0,5mm 1,0 ±0,05mm 41 ±0,1mm Heat shrinkable fiber optic splice protector SP/F25/2,5A Heat shrinkable fiber optic splice protector SP/F45/2,5A Art. No Art. No Adapter LC/APC 8 duplex flange with shutter Adapter with flange or snap-on mounting with shutter Adapter LCdx/APC 8 duplex flange with shutter Art. No Fiber optic patch panel Designed to storage fiber optic cables and splicing cassettes Intended for installing in 19 rack system Enable fiber optic termination and distribution Model offered: Resetable and sliding Installation depth: 250 mm Material: steel Powder coated Colour: RAL 7035 (Light Grey) - other colours on request Universal splice cassette holding system: fixed & booklet mounting option Equipped with removable splice cassette holder and antitwist system By default with 1 or 6 duplex adapters and pigtails 19 Fiber optic patch panel 24/1LCdx/APC 8 SM 1xPG16/1xAB RAL7035 complete Art. No Fiber optic patch panel 24/6LCdx/APC 8 SM 1xPG16/1xAB RAL7035 complete Art. No

27 Fiber-Pigtail Pigtails with optical fiber (600 µm acrylate buffer) and LC/APC8 connector Description of LC/APC simplex: user-friendly audible latch to indicate proper mating push-pull locking plastic housing with zirconia ferrule standard IEC insertion loss (IL) for SM (typical) mean value < 0.15 db (to reference connector) max. value < 0.30 db (to reference connector) return loss (RL) > 65 db 8 SM-Angle (APC) polishing PT LC/APC8 1E9/125/600/rt 1m for OTO Art. No PT LC/APC8 1E9/125/600/gn 1m for OTO Art. No PT LC/APC8 1E9/125/600/ge 1m for OTO Art. No PT LC/APC8 1E9/125/600/bl 1m for OTO Art. No PT LC/APC8 1E9/125/600/rt 2m for patch panel Art. No PT LC/APC8 1E9/125/600/gn 2m for patch panel Art. No PT LC/APC8 1E9/125/600/ge 2m for patch panel Art. No PT LC/APC8 1E9/125/600/bl 2m for patch panel Art. No FTTH in-house cable, installation cable on a cardboard reel I-VQ(ZN)H 4E9/125 FTTH in house cable preassembled with 2 LC/APC 8 connectors PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No PT LC/APC8 2E9/125/600/ m excl. OTO Art. No OPDISYS Fiber to the Home - Solution 02/2016 by Pengg Kabel GmbH Technische Änderungen vorbehalten 27

28 Fiber optic cables Fiber optic passive components Fiber optic installation services Fiber to the home - solutions Telecommunication cables Railway cables Copper cable installation services PENGG KABEL GmbH Plant Optic Breitenfeldgasse Sankt Barbara Plant Copper Mariazellerstraße Kapfenberg Tel.: / Fax.: /

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

RN Optical Termination Panel (RN OTP)

RN Optical Termination Panel (RN OTP) RN Optical Termination Panel (RN OTP) General The RN Optical Termination Panel(RN OTP) is specifically designed to house optical splitters while also catering for fiber termination in a single enclosure.

More information

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts This Specification is property of SEC and subject to change or modification without any notice Page 1 of 17 CONTENTS Clause Page 1 GENERAL 4 1.1 Scope

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks

More information

UTILUX CABLE MANAGEMENT

UTILUX CABLE MANAGEMENT Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. UTILUX CABLE

More information

Welcome to the market leader for state-of-the-art micro duct systems

Welcome to the market leader for state-of-the-art micro duct systems Welcome to the market leader for state-of-the-art micro duct systems Dear gabocom customers and partners Cordial thanks for your interest in our products and systems. Before familiarizing you with these

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

HDPE Conduit Specification 2011

HDPE Conduit Specification 2011 General This specification covers the minimum requirements for HDPE conduit and is based on ASTM F 2160. HDPE Conduit is for use primarily in underground applications as conduit, innerduct, direct buried

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

TECHNICAL DATA SHEET GRILON TS V0

TECHNICAL DATA SHEET GRILON TS V0 TECHNICAL DATA SHEET GRILON TS V0 General product description Grilon TS V0 is an unreinforced, normal viscosity, self-extinguishing PA66 + PA6 injection moulding grade. Grilon TS V0 has the following important

More information

SPECIAL SPECIFICATION 1663 Fiber Optic Cable

SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1993 Specifications CSJ 0192-01-080 SPECIAL SPECIFICATION 1663 Fiber Optic Cable 1. Description. This Item shall govern for the furnishing and installation of fiber optic cable in designated locations

More information

OPTICAL FIBRE CABLE PERFORMANCE

OPTICAL FIBRE CABLE PERFORMANCE WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Conergy SolarFamulus II

Conergy SolarFamulus II Conergy SolarFamulus II Installation manual www.conergy.com Table of Contents Table of Contents SolarFamulus II for universal use on flat roofs 1 Introduction 1 1.1 Short description 1 1.2 Intended use

More information

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System 2004 Specifications Houston District SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System 1. Description. Furnish and place a Multi-Duct Conduit (MDC) system that is suitable for installation in an outdoor

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

Standard program overview fire doors

Standard program overview fire doors Fire doors Standard program overview fire doors Fire-resistant and fire-proof steel doors Product Dimensions in mm width/height (clear opening) Tested as fire-resistant door in acc. with DIN 4102 / EN

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm Large plastic pipe technology Large diameter pressure pipe up to DN/ID 5000 mm Powerful and designed according to YOUR specifications Large diameter pressure pipes No sagging and less wallthickness saves

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

New consumer units. Design and functionality in plain sight.

New consumer units. Design and functionality in plain sight. New consumer units. Design and functionality in plain sight. CONSUMER UNITS A wide range of stylish solutions for any type of masonry or plasterboard wall. Consumer unit with white blind cover Consumer

More information

Panel elements. Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements

Panel elements. Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements Panel elements Closed Panels Transparent Panels Non-Transparent Panels Mesh Panels Accessories for Panel Elements Panel elements Products in this section Acrylic Glass Polycarbonate PET-G Sheet Material

More information

Multigates made of ShieldLine Materials

Multigates made of ShieldLine Materials Trelleborg Moulded Components ChemLine FoodLine ShieldLine FrictionLine Multigates made of ShieldLine Materials IP66/67, IP65, IP55, IP54 Multigates Multigates are metal or plastic reinforced cable gland

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Design Standard Conduit for Electrical Systems

Design Standard Conduit for Electrical Systems Design Standard Purpose: This design standard has the purpose of creating a consistent application for the installation of conduits throughout the East Side Union High School District, therefore achieving

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

Fiber Optic Panels. 1 st Edition

Fiber Optic Panels. 1 st Edition Fiber Optic Panels 1 st Edition Introduction Cable management is an essential consideration in any successful fiber communications network. The FMT series fiber optic panel enables termination, termination/splicing,

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

Rail anchoring systems Introduction Bottom-up post-installed method Top-down cast-in method. Rail anchoring systems

Rail anchoring systems Introduction Bottom-up post-installed method Top-down cast-in method. Rail anchoring systems Rail anchoring systems Rail anchoring systems Introduction Bottom-up post-installed method Top-down cast-in method 09 / 2014 These pages are part of the Anchor Fastening Technology Manual issue September

More information

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual Dome Heat Shrinkable Seal Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual 1. Scope of application This Installation Manual suits for the Optic Splice Closure (Hereafter abbreviated as FOSC),

More information

Cable junction boxes with intrinsic fire resistance and insulation integrity

Cable junction boxes with intrinsic fire resistance and insulation integrity PASSION FOR POWER. Reliable power supply, even in the event of fire Cable junction boxes with intrinsic fire resistance and insulation integrity E90 For more information see www.hensel-electric.de Planning

More information

PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER, CABLE CLASS SM AND MM

PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER, CABLE CLASS SM AND MM METRIC MIL-PRF-85045/16C 17 June 2014 SUPERSEDING MIL-PRF-85045/16B 16 September 1999 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SINGLE (ONE) FIBER, CABLE CONFIGURATION TYPE 2 (OFCC), TIGHT BUFFER,

More information

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

New designed XLPE-insulated cables substituting paper-insulated pipe type cables MODERN CABLE SYSTEMS IN STEEL PIPES New designed XLPE-insulated cables substituting paper-insulated pipe type cables Volker AUE, Nexans Deutschland Industries, Germany, Volker.Aue@nexans.com Wilfried ROSEBROCK,

More information

MAKING MODERN LIVING POSSIBLE. Danfoss Pipes for Hydronic Floor Heating. Handbook DANFOSS HEATING SOLUTIONS

MAKING MODERN LIVING POSSIBLE. Danfoss Pipes for Hydronic Floor Heating. Handbook DANFOSS HEATING SOLUTIONS MAKING MODERN LIVING POSSIBLE DANFOSS HEATING SOLUTIONS Handbook Index Page Danfoss FH Pipes...................................................... 3 FH Composite pipes....................................................

More information

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply. I. References When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply. II. Listing The conduit shall be listed by

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

ENERGY-DISTRIBUTION. TwinLine N 44 The new system of floor-standing cabinets in IP44

ENERGY-DISTRIBUTION. TwinLine N 44 The new system of floor-standing cabinets in IP44 ENERGY-DISTRIBUTION TwinLine N 44 The new system of floor-standing cabinets in IP44 2 FLOOR-STANDING CABINETS TWINLINE N 44 2CPC 000 351 B0201 PRODUCT BENEFITS The new system of floor-standing cabinets

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 6/15/16 Updated division section from 16124 to 2605 - mgl44 13, removed references to other section 10/17/14

More information

Hoesch isodach integral Technical information

Hoesch isodach integral Technical information Technical information A company of ThyssenKrupp Steel tk Contents Page General 3 Main dimensions and properties 4 Corrosion protection 5 Thermal protection / Insulating core 5 Fire protection 5 Information

More information

Microcable & Microduct NEXT GENERATION FTTx ACCESS CABLE SYSTEMS

Microcable & Microduct NEXT GENERATION FTTx ACCESS CABLE SYSTEMS Microcable & Microduct NEXT GENERATION FTTx ACCESS CABLE SYSTEMS Pete Carapella Caribbean Cable & Telecommunications Association July, 2016 Solving the FTTP Challenge As operators around the world ramp

More information

Contents Overview. Pipe. Fittings. Features & benefits. Installation considerations. Tools & terminology

Contents Overview. Pipe. Fittings. Features & benefits. Installation considerations. Tools & terminology pexplus manual 1 pexplus Contents 2 3-6 7 8 8-11 12 13-16 17-18 19-25 Overview Pipe Fittings Features & benefits Installation considerations Tools & terminology Jointing instructions FAQ Pex fitting range

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

MDS TL4 Minimum Deflection Systems

MDS TL4 Minimum Deflection Systems MDS Approvals FHWA NCHRP 350 MASH-08 EN1317 H2 Bridge & Road STEEL BARRIER SYSTEMS Page 1 V11 Run-off-road crashes are one of the most common types of crashes in urban and highway environments. Installing

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

HIGH MAST CAMERA POLE ASSEMBLY GENERAL 10-3.24 HIGH MAST CAMERA POLE ASSEMBLY GENERAL The Contractor must furnish and install the following equipment for high mast camera pole assembly as described herein and as shown on the plans: 1. Camera

More information

MDS TL5 Minimum Deflection Systems

MDS TL5 Minimum Deflection Systems MDS Minimum Deflection Systems Approvals FHWA NCHRP 350 MASH EN1317 H4 MDS BARRIERS Bridge & Road STEEL BARRIER SYSTEMS Page Page 1 1 V11 MDS BARRIERS Run-off-road crashes are one of the most common types

More information

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S LOADING DOCK SYSTEMS LOADING DOCK SYSTEMS Loading dock systems enable

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm Series PV Single layer design, thermal conductivity k = 5 W/m 2 K For wall mounting by hanging and standing installation Torsion resistant, self-supporting casing without joints, corrosion and seawater

More information

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1 Hose protection Edition: 02/2008 Catalogue 1 12 Note All the information in this catalogue is based on the standards applicable at the time of publication and the regulations of the employers liability

More information

PETREX -CNT. Pipe systems for petrol stations Technical details

PETREX -CNT. Pipe systems for petrol stations Technical details PETREX - Pipe systems for petrol stations Technical details Contents 1.0 1.0 Contents 1.10 1.100 System description System description PETREX - 1.11 1.11.01 Product overview Piping, connections, fittings

More information

Luka Quality Assurance Manual (Eng)

Luka Quality Assurance Manual (Eng) Luka Quality Assurance Manual (Eng) Contents: 1 General... 3 1.01 Foreword... 3 2. Quality assurance standards for air ducts... 4 A.1.00 Rectangular galvanised steel ducts... 4 A.2.00 Embedded galvanised

More information

Expanded Beam Optical Termini

Expanded Beam Optical Termini 8D Series & ARINC 600 Series ELIOBEAM Fiber Optic Contact Expanded Beam Optical Termini The optical connection requirement for environmentally exposed mating cycles. Robust to contamination Large beam

More information

CABLE MANAGEMENT SOLUTIONS

CABLE MANAGEMENT SOLUTIONS CABLE MANAGEMENT SOLUTIONS Cope with any Cabling Challenge A PART OF No matter the application, COPE has COPE Ladder Tray is the cost-effective solution for power, control, instrumentation cable, and other

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATION FOR REINFORCED SOIL WALL SPECIFICATION FOR REINFORCED SOIL WALL 1.0 EXTENT OF WORK The work shall consist of Reinforced Soil walls built in accordance with this specification and in conformity with the lines, levels and details

More information

ProShell Support Profile for AS/RS and Transfer Cars. An Option for Conductix-Wampfler Conductor Rail Systems

ProShell Support Profile for AS/RS and Transfer Cars. An Option for Conductix-Wampfler Conductor Rail Systems for AS/RS and Transfer Cars An Option for Conductix-Wampfler Conductor Rail Systems Table of Contents System Description 4 System Advantages 5 Technical Data 6 Modular Concept 6 Basic Modules 7 ProShell

More information

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

31-SDMS-03 REV. 01 SPECIFICATIONS FOR 31-SDMS-03 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE CABINET FOR POLE MOUNTED TRANSFORMER This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Description

More information

FERROPLAST Panels: Underway on all roads. Configurator

FERROPLAST Panels: Underway on all roads. Configurator FERROPLAST Panels: Underway on all roads Configurator Trailer Services Technology FERROPLAST installed to meet your requirements. This brochure not only presents you with the many advantages of the long-lived

More information

CONFORMITY AND APPROVAL

CONFORMITY AND APPROVAL Polyester Enclosure Polyester Enclosure CONFORMITY AND APPROVAL Heal-moulded polyester enclosures, in grey colour RAL-9002. Self-extinguishable materials, as per ASTM D6. Extreme utilization temperatures:

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality

NASSAU Panorama. Showrooms. NASSAU Panorama 4.1. You know the Quality 4.1 Showrooms has been designed specially for buildings where a lot of natural light is required, as the windows do not have any vertical bars. The door appears elegant with its clean lines and lets lots

More information

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Custom-Designed Clamps. Machined Versions.  Online Configurator for Custom-Designed Clamps A56. Custom-Designed Clamps Machined Versions Custom-designed clamping systems for pipes, tubes, hoses, cables and other components according to customer`s specifications or based on developments, made of thermoplastics,

More information

POST TENSIONED SLABS. Imagineering the possibilities

POST TENSIONED SLABS. Imagineering the possibilities POST TENSIONED SLABS Imagineering the possibilities imagineering... CCL post - tensioned slab solutions represent continuous development through involvement in building structures worldwide. CCL systems

More information

TECHNICAL DATA SHEET GRILAMID L 20 LF GREY

TECHNICAL DATA SHEET GRILAMID L 20 LF GREY TECHNICAL DATA SHEET GRILAMID L 20 LF GREY General product description Grilamid L 20 LF grey is a medium viscosity graphite filled Polyamide 12 (PA12) grade suitable for both injection moulding and extrusion

More information

SX-FOSC-D-48 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

SX-FOSC-D-48 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) SX-FOSC-D-48 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) Installation Manual 1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated

More information

Heatshrink & Cable Repair Solutions

Heatshrink & Cable Repair Solutions PAGE EASI-SHRINK HEATSHRINK SLEEVING ZERO-HALOGEN HEATSHRINK SLEEVING DR-25 HEATSHRINK TUBING KYNAR HIGH TEMPERATURE HEATSHRINK HEATSHRINK KITS ADHESIVE LINED HEATSHRINK SLEEVING 347-348 349-350 351 352

More information

etwork etwork-/ethernet-/foc-cable

etwork etwork-/ethernet-/foc-cable etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet

More information

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) Installation Manual 1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated

More information

THE ADVANTAGES HDPE MANHOLES

THE ADVANTAGES HDPE MANHOLES NIC HDPE manholes are custom fabricated for many varied applications including municipal and industrial manholes, sewer and storm water manholes, leach ate collection, sewer lift stations, siphon structures,

More information

FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System

FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System Product Focus F.A.S.T. System can be installed independent of the floor system. Stackable to create multiple tiers. No tools required

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply. I. References When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply. II. Listing The conduit shall be listed by

More information

Modularity. Flexibility is maximized with basic modular components that combine to create many configurations.

Modularity. Flexibility is maximized with basic modular components that combine to create many configurations. Product Specification Document Date Published: September 17, 2004 AXIOM CONSOLE ABOUT AXIOM CONSOLE The ultimate in affordable modularity, the Axiom console family with its space age, structural polymer

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Logistics and industry. Consignment sales

Logistics and industry. Consignment sales Logistics and industry Consignment sales Saving time and money for consignment sales Wanzl - a renowned name in the trade for more than 50 years and still favoured today for its sophisticated universal

More information

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West Exposition East West CONTENTS 1 Notes on the Sika SolarMount 1 system (Exposition East West) for PV solar arrays 3 2 Setting up on site 3 3 Required Tools for mounting Sika SolarMount 1 to Sika roofing

More information

2016/17. hygienic product range brochure. the power in cable protection

2016/17. hygienic product range brochure. the power in cable protection WWW.FLEXICON.UK.COM 2016/17 hygienic product range brochure the power in cable protection Open to reveal more about our hygienic range Product Features & Benefits Introducing Flexicon s new range of hygienic

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET METRI MIL-PRF-85045/29B 9 June 2014 SUPERSEDING MIL-PRF-85045/29A 14 May 2009 PERFORMANE SPEIFIATION SHEET ABLE, FIBER OPTI, TWELVE/EIGHTEEN FIBER BUNDLE, BLOWN OPTIAL FIBER, ABLE ONFIGURATION TYPE 3 (ABLE

More information

Type II Environmental Declaration according ISO 14021:2001/A1:2011

Type II Environmental Declaration according ISO 14021:2001/A1:2011 Type II Environmental Declaration according ISO 14021:2001/A1:2011 Product: Hunter Douglas Panels Module 200-600mm Product code: 26005 Module 601-900mm Product code: 26025 Module 901-1200mm Product code:

More information

Fixed & Tilt-Over Cabinet Base TC & TCTO Range

Fixed & Tilt-Over Cabinet Base TC & TCTO Range TC & TCTO Range Technical Specification All dimensions in mm unless otherwise stated Standards Applicable - Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997 - General Steelwork: BS1449:1991,

More information

Versatile & High Performance LED

Versatile & High Performance LED logical Acciaio is Italian for steel, the element used in the overall construction; taking advantage of the durability and formability characteristics of steel. With the high percentage of reuse and recovery

More information

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03 mediatek Library and archive shelving systems Taking shelving to the next level BC004.03 mediatek Library and archive shelving systems The Mediatek range of shelving is designed to offer space efficient

More information

PSI Anti-Corrosion Tapes

PSI Anti-Corrosion Tapes Pipeline Accessories PSI Anti-Corrosion Tapes General Information Technical Data Requirement Specifications Application Instructions Certificates 1 The Systems PSI anti-corrosion tapes have been specially

More information

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages. 02 Stainless Steel Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution,

More information

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures BPG 42 The BPG range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

+44 (0)

+44 (0) Greenlee processing tools make your workshop mobile. This makes you much more flexible and efficient in plant and control cabinet construction. Friedrich Reusch 582 Special cutting tools 584 Machining

More information

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity Blue-Tip SCREW-BOLT Introduction Blue -Tip SCREW-BOLT anchors have many unique features and benefits that make this innovative anchor well suited for almost every application. Optimum performance is obtained

More information

Trenchless building entries Power and communication. Always. Reliable. Tight. cablepipebuildingentry+ Advantages:

Trenchless building entries Power and communication. Always. Reliable. Tight. cablepipebuildingentry+ Advantages: Always. Reliable. Tight. Advantages: no need to dig a trench on the outside of building can be fully installed from the inside of building ideal for applications where the connection line for the house

More information

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application Introduction Designed for Indoor and outdoor applications Non-tension tap and splice applications Used

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings Version:- 5.0 Date of Issue:- July 2017 Page 1 of 12 NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings 1. Purpose The purpose of this document is to outline the technical

More information

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the

More information