CAREX "Australia's Premier Health & Aged Care Expo"April 7th 2011
|
|
- Maud King
- 6 years ago
- Views:
Transcription
1 FOODSERVICE COMPLIANCE WITH AUSTRALIAN STANDARDS Presented by: Brian J. Lennox FCSI CAREX "Australia's Premier Health & Aged Care Expo"April 7th
2 FOODSERVICE COMPLIANCE WITH AUSTRALIAN STANDARDS In aged care foodservice operations there is no right or wrong method of delivery. The method of food delivery is determined by a number of factors; The type of resident, low, high or extra service? Religious and cultural demands, the financial demographic of the resident and staffing restraints to name a few. The method of production can be based on a limited number of methods. - Cook fresh - Cook chill/regeneration - A combination cook fresh/cook chill Today, we are looking not at these points but at the building fabric and associated fittings THAT SUPPORT THE PROPOSED METHOD OF SERVICE. 2
3 Have you seen equipment looking like this? 3
4 Or, what about this? 4
5 5
6 All of these pictures are non compliant with Australian Standards When we talk about Australian Standards in foodservice we are referring to; AS Design, Construction & fit-out of food premises. This document can be purchased from We also look at Safe Food guidelines & standards such as AS4586 flooring, AS3000 electrical wiring & BCA guidelines for the safe egress of cold rooms. Notes... 6
7 Points of discussions & review We want to look at the key points that are raised in a large percentage of projects. The safe egress from cold rooms Wall construction & finishes Wall & floor finishes Hand basins what type and where are they required. Pipe work and electrical conduit Domestic refrigeration can they be used in a Servery or pantry situation? 7
8 Safe egress of cold rooms BCA Clause GP1.3 States that a cold room needs to have a means of alerting and/or communicating with persons on the outside of the room and be open able from the inside. In addition to that it stipulates that a strong or secured room (which a cold room is deemed to be) will have internal lighting, controllable from the inside. A large percentage of cold rooms currently DO NOT COMPLY. This is a real issue as it is a potential OH&S risk. 8
9 Wall construction & finishes In accordance with AS in section notes that walls in foodservice areas need to be of a solid construction. This prevents the harbourage of vermin and pests in these walls. Walls can be finished in accordance with table 3.2 of the standard. This table has been added to the documents provided to you all today. 9
10 Wall finishes Wall finishes need to be in line with AS table 3.2. In short they need to cleanable, not collect grease or dust, be free of buckles and ledges and have a smooth finish. Wall tiles don t need to be white. 10
11 Floor finishes Floor finishes need to be in line with AS4586 and be slip rated in line with this with this standard. Floor and wall junction needs to be coved in line with AS section 3.1 Notes... 11
12 Hand basins Hand basins need to be hands free. This means no levered tap ware. Water can be dispensed via a knee push panel or an electric sensor. Where should a hand basin be positioned? Hand basins are to be provided in all parts of the facility where food is handled (As section 4.4.1) Hand basins are to be provided in utensil washing areas (AS section 4.4.1) Be accessible and no further that 5 meters from where food is handled. Be complete with a soap and towel dispenser installed over it. If possible have hot and cold water installed under it. Notes
13 Pipe work and electrical conduit To comply with AS all pipe work needs to be installed in standoff brackets. All copper pipe work need to be painted in epoxy based paint or chromed to reduce issues relating to copper oxidization poisoning. This applies to cool room drain lines, electrical conduit, copper gas and water lines, gas lines and fire suppression pipe work. Pipe work must be cleanable and not collect duct, grease and dirt. Notes... 13
14 Domestic refrigeration can they be used in a servery or pantry situation? Victorian Legislation actually restricts the Use of Domestic Kitchens for Production of Food for Sale and dispensing. Most domestic refrigerators do not have temperature reading devises and are designed for domestic use. This means that they are designed to be opened far less than a commercial refrigerator. In turn this means they eventually cost more to run and struggle to regain temperature. We do not recommend domestic refrigeration in aged care operations. Notes
15 Conclusion The care of our elderly is the most important factor in delivering a quality foodservice today. The building fabric and associated fitting AND THE CORRECT USE AND INSTALLATION of these items assists in meeting that demand. Thank you 15
SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)
SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) Construction Criteria The unit costs for the Physical Fitness Center (Exercise Room) space type are based on the construction quality and design features in
More informationMilk and Dairy Products
Industry Guide to Good Hygiene Practice Milk and Dairy Products Regulation (EC) No. 852/2004 The hygiene of foodstuffs Regulation (EC) No. 853/2004 Hygiene rules for food of animal origin Regulation (EC)
More informationGUIDELINES FOR SANITARY DESIGN AND CONSTRUCTION OF MILK PRODUCTS PLANTS (rev )
Milk and Dairy Food Safety Branch 1220 N Street, Sacramento, CA 95814 GUIDELINES FOR SANITARY DESIGN AND CONSTRUCTION OF MILK PRODUCTS PLANTS (rev. 10-20-2011) The outline below lists sanitary requirements
More informationASEAN Guidelines on GMP for Traditional Medicines / Health Supplement
ASEAN Guidelines on GMP for Traditional Medicines / Health Supplement Prepared by: PHILIPPINES Approved by: ASEAN TMHS GMP Task Force Endorsed by: ASEAN TMHS Product Working Group OUTLINE 1. Principle
More informationOvernight Prep Table Storage
Overnight Prep Table Storage Debunking the myth of safe & effective overnight prep table storage Food Storage Options in Today s Foodservice Industry Today s foodservice industry has put a large emphasis
More informationAppendix II FSEP Prerequisite Program Checklist
Appendix II FSEP Prerequisite Program Checklist Appendix II - FSEP Prerequisite Program Checklist Establishment Name Registration Number: CFIA Auditor: Review the establishment s written prerequisite
More informationADVANCED.fst FOOD SAFETY TRAINING IN CANADA PRETEST
ADVANCED.fst FOOD SAFETY TRAINING IN CANADA PRETEST PART 1 THE CHALLENGE TO FOOD SAFETY What is the difference between clean and sanitary? Clean means Sanitary means Name seven potentially hazardous foods.
More informationContracted Scope ABC of the Carolinas Excellence in Construction Awards Carolinas HealthCare System CMC Kitchen Healthcare.
Contracted Scope Provide a detailed description of your scope for this project. Responses should include: type of construction; size of project; contract value; length of project; and percentage of labor
More informationIN OUT COS NO NA R 10 Food and warewashing equipment approved, properly designed, constructed and installed.
SOUTHERN NEVADA HEALTH DISTRICT Page 1 of 5 FOOD ESTABLISHMENT INSPECTION 280 SOUTH DECATUR BLVD LAS VEGAS, NV 89107 702-759-1258 (DIRECT PLAN REVIEW) 702-759-1110 (DIRECT FOOD OPS) 702-759-1000 (24 HOURS)
More information35.0 Sterile Supply Unit (SSU)
35.0 Sterile Supply Unit (SSU) 35.1 Introduction 35.1.1 General A Hospital must provide adequate facilities for cleaning, sterilisation and storage of equipment and instruments to ensure the care and safety
More informationRENOVATIONS & REFURBISHMENTS
RENOVATIONS & REFURBISHMENTS This Activity received funding from the Department of Industry as part of the Energy Efficiency Information Grants Program The nature of the tourism and hospitality industries
More informationJACKSON COUNTY, MISSOURI FOOD ESTABLISHMENT PLAN REVIEW APPLICATION FOR A NEW MOBILE UNIT Plan Review / Pre-Opening Inspection Fee $300
Date: JACKSON COUNTY, MISSOURI FOOD ESTABLISHMENT PLAN REVIEW APPLICATION FOR A NEW MOBILE UNIT Plan Review / Pre-Opening Inspection Fee $300 Permit Fees Permit fees are determined by using a priority
More informationMODULE 14: Off-site Transport and Storage of Healthcare Waste
MODULE 14: Off-site Transport and Storage of Healthcare Waste Module Overview Define external transport of healthcare waste Describe requirements for off-site transport of healthcare wastes including training
More informationSHS Building Consultants. Ph Job Details. Photograph shows the front elevation of the residence.
Practical Completion Report Inspection date 1 st January Client Mohit Vir Job Details Address Lot 3349 Limone street Aveley. W.A. Photograph shows the front elevation of the residence. DESCRIPTION OF THE
More informationAUSTRALIAN TRAINING SOLUTIONS Assessment Tool Cover Sheet: Food Safety ONLINE
AUSTRALIAN TRAINING SOLUTIONS Assessment Tool Cover Sheet: Food Safety ONLINE Units of Competency: SITXFSA001 Use hygiene practices for food safety Training Package: From SIT16 Tourism, Travel & Hospitality
More informationTable of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities
Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)
More informationTicking Form - Lodge - 1 -
Swaziland Tourism Authority Registration of Accommodation Establishments Ticking Form Lodge Name of Establishment: Name of Contact / Manager: Reference number: 1 Guest rooms Single/Double/Family 1.2 Size
More informationSECTION COOLING TOWER
PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue
More informationAQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters
AQUATITE Revision Date: september 2007 Description Bondall AquaTite is a grey, brushable, waterproofing coating that forms a flexible yet tough, seamless membrane. This single pack product exceeds the
More informationEvergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program
Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program The following table provides a brief description of the documentation that will be required of successful LIHTC
More informationST ANNE S CATHOLIC CHURCH EXISTING CONDITIONS REPORT 84 AUSTIN ROAD, SEAFORD
EXISTING CONDITIONS REPORT 84 AUSTIN ROAD, SEAFORD JULY 2016 INTRODUCTION This report has been prepared to assist with the review of the existing conditions at the existing St Anne s Catholic Church at.
More information3. Sanitary Plumbing Single Stack System
3. Sanitary Plumbing Single Stack System On completion of this section, students should be able to: Design, install and develop bills of quantities for the Single Stack Systems for domestic, commercial
More informationWhat you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations
What you need to know about 6 Star 6 Star for new homes, home renovations, alterations, additions and relocations Introduction From 1 May 2011, all new homes, home renovations, additions, alterations and
More informationFood sanitation and hygiene
Food sanitation and hygiene Food sanitation implies Cleanliness Preparing Storing & Serving of food & water Food sanitation is essential aspect of food preparation Some items need particular attention
More informationBUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS. March 2014
BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS March 2014 Energy Safe Victoria (ESV) continues to receive complaints concerning defective builder s construction supplies.
More informationSTEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS
GUIDE FOR TIMBER AND CONCRETE FLOORS EDITION: APRIL 2016 IMPORTANT: This guide is for the installation of a Step Up shower base on a timber or concrete floor. If you require a walk in (flush with floor)
More informationKIOSK DESIGN CRITERIA
KIOSK DESIGN CRITERIA ADDENDUM LOG July, 2008 Full Update September, 2011 Content update (image replacements and content additions) November, 2011 Grammar corrections, minor cleanup. (5, 11) January, 2012
More informationGeneral Guidance for Developing, Documenting, Implementing, Maintaining, and Auditing an SQF System
General Guidance for Developing, ing, Implementing, Maintaining, and Auditing an SQF System Module 11: Good Manufacturing Practices for Processing of Food Products SQF Code, Edition 7.2 JULY 2014 2014
More informationW i s d o m S m a r t C o l l e c t i o n. Inspiration series
W i s d o m S m a r t C o l l e c t i o n Inspiration series Inspiration 30 Area Calculations INSPIRATION 30 This home has 13.5 been designed to fit a m lot width 11510mm Itemised Floor Areas Garage Porch
More informationMETHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES
This Document is designed to cover best practice installation methods for the installation of a class 2/3 waterproof membrane system to external concrete balconies in accordance with AS 4654.2 PRELIMINARY
More informationRetail Foodservice. Meeting the unique demands of the industry
Retail Foodservice Meeting the unique demands of the industry By 2022 prepared food purchases in the retail segment are expected to grow 10% Percentage of grocery shoppers that visit with the sole intent
More informationSanitation Standard Operating Procedures. New Juice Co
Sanitation Standard Operating Procedures New Juice Co 123 Petunia Drive Anywhere, CA 98765 1. SAFETY OF THE WATER THAT COMES INTO CONTACT WITH FOOD OR FOOD-CONTACT SURFACES, OR IS USED IN THE MANUFACTURE
More informationIntegrated Pest Management in Section 8 Multifamily Housing 1
Integrated Pest Management in Section 8 Multifamily Housing 1 Integrated Pest Management in Section 8 Multifamily Housing Cockroaches 1 Outline What they are What they eat Where they live How to think
More informationPLYMOUTH BOARD OF EDUCATION
PLYMOUTH BOARD OF EDUCATION PURPOSE: Green cleaning products have increased in importance, as health studies have documented what adverse effects most commercial chemical cleaning products have, not only
More informationN O V E M B E R
General Guidance for Developing, ing, Implementing, Maintaining, and Auditing an SQF System Module 11: Good Manufacturing Practices for Processing of Food Products SQF Code, Edition 8 N O V E M B E R 2
More informationZip Freestanding Chilled Water Systems
Installation and Operating Instructions Zip Freestanding Chilled Water Systems Affix Model Number Label Here 81507 GP 81507 - Zip Freestanding Chilled Water Systems - Installation & Operating Instructions
More informationMEZZAFLOR - SPACE TO WORK.
MezzaFloor Brochure.indd 1 MezzaFloor Brochure.indd 2 MezzaFlor design, supply and install mezzanine floors for the warehouse storage, laboratory s, boardrooms, cool rooms, dust free storage and office
More informationThe Design of the Suspended T-bar Ceilings in accordance with AS for the New Royal Adelaide Hospital
The Design of the Suspended T-bar Ceilings in accordance with AS 1170.4 for the New Royal Adelaide Hospital J. Woodside BEng, MEng Sc, F.I.E.Aust, F.A.S.C.E, F.I.C.E, F.I Struc.E Principal, J Woodside
More informationWater Quality in East Chicago. December 12, 2016
Water Quality in East Chicago December 12, 2016 What is lead? Lead is a toxic colorless, odorless, and tasteless metal It is found throughout the environment In the past lead was often used in: Paint Gasoline
More informationApplied Maintenance Supplies & Solutions
Applied Maintenance Supplies & Solutions SM Inventory Management, Vending and More Applied Maintenance Supplies & Solutions (Applied MSS SM) brings lean principles to your management of MRO consumables
More informationRLP approved 11 April 2013 QuickBayt Spray Fly Bait Page 1 of 8 CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING
RLP approved 11 April 2013 QuickBayt Spray Fly Bait Page 1 of 8 Main panel CAUTION KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING QuickBayt Spray Fly Bait ACTIVE CONSTITUENTS:
More informationThis policy will generally explain the following in regards to the City sewerage collection systems:
CITY OF SACO POLICY ON SEWER AND STORMWATER BACK-UPS PURPOSE The purpose of this policy is to explain how and why sewer or stromwater backups occur, what to do in the event a homeowner has a backup, and
More informationMODULAR BUILDING SPECIFICATIONS
Use Group A - Assembly B Business E Education I - Institutional Construction Type Type II Non Combustible Type V - Wood Floor 12 Outrigger Frame with Cross members Frame: 12 Perimeter Steel Main Beams
More informationSILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION
SILASEC WP0001 REVISED: JANUARY 2002 DESCRIPTION Bondall Silasec is a concentrated liquid waterproofing compound designed to be used with Portland type A or type GP cements to form a permanent waterproof
More informationKEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT
KEVIN BURNS HOMES PRACTICAL COMPLETION REPORT VISUAL BUILDING INSPECTION REPORT No. 764 CLIENT: PROPERTY ADDRESS: Jindalee DATE: 25 November 2016 WEATHER: Fine ARRIVAL TIME: 8.15am DEPARTURE TIME: 10.30am
More informationVERMONT MAPLE SUGAR MAKERS ASSOCIATION 491 East Barnard Road South Royalton, VT SUGARING OPERATIONS CERTIFICATION SCORE SHEET
VERMONT MAPLE SUGAR MAKERS ASSOCIATION 491 East Barnard Road South Royalton, VT 0068 802-498-7767 mgordon@vermontmaple.org SUGARING OPERATIONS CERTIFICATION SCORE SHEET Business Name: Number of Taps Address:
More informationSOUTHERN NEVADA HEALTH DISTRICT
SOUTHERN NEVADA HEALTH DISTRICT Page 1 of 5 FOOD ESTABLISHMENT INSPECTION 280 SOUTH DECATUR BLVD LAS VEGAS, NV 89107 702-759-1258 (DIRECT PLAN REVIEW) 702-759-1110 (DIRECT FOOD OPS) 702-759-1000 (24 HOURS)
More informationFire protecting windows close to boundaries
Fire protecting windows close to boundaries product solutions Q1 Queensland Hyundai Head Office Sydney Digital Life Labs Melbourne ANZ Head Office Melbourne Stockhome, Stocklands HQ Sydney T: 1300 655
More informationKelly Village Apartments 3118 Green Houston, Texas 77020
Kelly Village Apartments 3118 Green Houston, Texas 77020 Houston Housing Authority J. Allen Management Managing Agent Scope for Kelly Village Unit #1125 Overall Scope: Demolition, Renovation, and Restoration
More informationProcurement services. real
Procurement services MAKE A real IMPACT Make a real impact That s what our procurement frameworks can do for you. They re designed to bring genuine, cashable cost efficiencies to your public sector work
More informationBasic Design Considerations for a Laboratory. The Ministry of Health & Family Welfare, under the Drugs & Cosmetics Act, laid down
Basic Design Considerations for a Laboratory Archana Salil, Director and Principal Architect- Arena Consultants The Ministry of Health & Family Welfare, under the Drugs & Cosmetics Act, laid down Good
More information6.1 Introduction to Wastewater Issues
Section 6: Water Pollution This Section will help you: Understand if you generate industrial wastewater; Understand where your wastewater goes; Make sure you meet requirements for floor drains; Properly
More informationRevision Date: February 28,
FACILITY SERVICES - REQUIREMENTS FOR PLUMBING, FIRE PROTECTION, HVAC, AND ELECTRIC DOCUMENTS 2007 Edition, Published April, 2007, Revision Date: February 28, 2018 FS-1. SEPARATE DOCUMENTS REQUIRED.2 SEPARATION
More informationWALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof
WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS DESCRIPTION BASIC STRUCTURE Foundation Super Structure Internal Walls External Walls Roof RCC footing Framed Structure 200 & 100 mm Solid Concrete Blocks
More informationASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET
EP IDE KE GU IS TH ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET Asbestos could be in the house or building you are working on right now. Left alone, it isn t dangerous. However, once disturbed, tiny
More informationAppendix B. Sanitation Performance Standards
Appendix B Sanitation Performance Standards The following are excerpts from FSIS Directive 11000.1 (FSIS, 2000). A. Grounds and Pest Control 1. What are the regulatory performance standards for grounds
More informationStand construction regulations Horecava 2018:
Stand construction regulations Horecava 2018: The stand construction regulations are an addition to the Specific Terms and Conditions Horecava 2018. The Stand Design department of RAI Amsterdam does assist
More informationBAMCO Food Safety Guidelines
BAMCO Food Safety Guidelines Bon Appétit Management Company Farm to Fork Program Produce Supplier Quality Assurance Requirements GENERAL REQUIREMENTS FOR ALL FIRMS / FACILITIES IMPLEMENTATION OF A FOOD
More informationNUISANCE AND GENERAL SANITATION REGULATION
Province of Alberta PUBLIC HEALTH ACT NUISANCE AND GENERAL SANITATION REGULATION Alberta Regulation 243/2003 With amendments up to and including Alberta Regulation 162/2014 Office Consolidation Published
More informationSPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER
SPECIFICATIONS FOR THE INSTALLATION OF REDUCED PRESSURE BACKFLOW PREVENTERS AND CONCRETE VAULTS FOR METERS 4 AND LARGER Updated January 2018 RP-2 Installation Specifications 1. In W.H.U.D s service area
More informationWaterproofing Handbook
Waterproofing Handbook Wet-seal R Your Waterproofing Specialists Your Waterproofing Specialists Basic Hand Book for Waterproofing Builder s/client Responsibilities Safe Working Site Duty Of Care The Builder/Client
More informationUFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-07 16 19 (January 2007) ---------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-07 16 19 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System
SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF WELDED SYSTEM PART 1 GENERAL 1.1 SECTION
More informationTraining Modules on Food Safety Practices for Aquaculture. Food Safety Practices for Aquaculture
Training Modules on Food Safety Practices for Aquaculture Food Safety Practices for Aquaculture Introduction This module is part of a training program on Food Safety Practices for the Aquaculture Industry.
More informationFor Sale. 42 Prospect Road, Portstewart, BT55 7LQ. Offers Over 189,500. Property Overview
For Sale 42 Prospect Road, Portstewart, BT55 7LQ Offers Over 189,500 Property Overview - Situated close to Portstewart Strand beach and golf courses - Modernised by current owners - Excellent residential
More informationDAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone
Revised: 1/29/16 DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone Professional painter formula Paint in 20 minutes Spray paint immediately Crack resistant Reduced dirt pick-up Won t shine through paint
More informationPIP STF05520 Details for Pipe Railing for Walking and Working Surfaces
TECHNICAL CORRECTION January 2017 Structural PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process
More informationRapini Pty Ltd - Master Logotype March 2011 Process 541C Cyan C TEM S Y VING S WIRE SHEL
WIRE SHELVING SYSTEM 01 INTRODUCTION Rapini delivers an easy and economical way to solve a variety of storage, supply management and inventory control issues with Static and Mobile Wire Shelving Systems.
More informationPortaFloor PRO Rollable Event Flooring Installation and Maintenance Guide
PortaFloor PRO Rollable Event Flooring Installation and Maintenance Guide Copyright 2011 Sport Court, International, Inc. Copyright 2011 Sport Court, Inc. PortaFloor is a registered trademark of Sport
More informationOperational Guideline: Design and Construction of Dairy Premises and Equipment 13 April 2006
Te Pou Oranga Kai O Aotearoa Operational Guideline: Design and Construction of Dairy Premises and Equipment 13 April 2006 New Zealand Food Safety Authority PO Box 2835, Wellington, New Zealand 13 September
More informationInstallation Instructions
Installation Instructions Before you begin, you will need the following tools and supplies: A clean or new 5 gallon bucket. You will need to either replace or clean your bucket after each 5 kits or before
More informationSECTION CERAMIC TILE
SECTION 09300 CERAMIC TILE PART 1 GENERAL 1.1 SCOPE A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions, Division 00 & 01 Specification Sections,
More informationInstallation Guide Details correct as of December 2013
Installation Guide Details correct as of December 2013 Pre-installation checklist Solid/Screed floors 1. Insulation fitted neatly and stable with all gaps and joints taped 2. If using liquid screed, a
More informationTECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.
More informationRFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES
RFP/GRC/LSV/2017-003: RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES 1/7 The Contractor shall consider in his price all costs or expenses of all requirements stipulated
More informationSeamless colour and sheen
GLASS SPLASHBACKS Seamless colour and sheen Glass splashbacks are the ultimate choice in providing a perfect finish for your home that is durable, beautiful, colourful and easy to clean! This amazing finish
More informationAsbestos in Your Home
Asbestos in Your Home Your guide on where it may be used and what to do if it s in your home the facts Sandbourne Housing Association Registered Office: Beech House, 28-30 Wimborne Road, Poole, BH15 2BU
More informationBudget Estimate Basic Tenant Improvement
Building work rules, conditions and insurance: 1. Review the work rules. If they are not available no budget should be provided. 2. Hours available for construction 3. Insurance requirements 4. Entities
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More informationBCA Section J Compliance Report. Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown
BCA Section J Compliance Report Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown Prepared by: Gradwell Consulting ABN 68 872 791 784 Sustainability Consultants PO Box
More informationEVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN
EVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN - CREDIT(S) EARNED ON COMPLETION OF THIS COURSE WILL BE REPORTED TO AIA CES FOR AIA MEMBERS.
More informationSCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD AND
SCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD Zotos Place, 37 Old Kilcullen Road, Bryanston P O Box 68012, Bryanston, 2021 Tel: 011 463 2124 Fax: 011 463 2129 AND ERF: TOWNSHIP:
More informationADVANCED.fst FOOD SAFETY TRAINING IN CANADA PRETEST - ANSWERS
ADVANCED.fst FOOD SAFETY TRAINING IN CANADA PRETEST - ANSWERS PART 1 THE CHALLENGE TO FOOD SAFETY 1. What is the difference between clean and sanitary? Clean means free of visible soil, food residue and
More informationProperty Maintenance Capability Statement
Property Maintenance Capability Do you manage the maintenance for a commercial or industrial property? Do you find it hard to get tradesmen when you need them most? Do you have a preventive maintenance
More informationDetailing guide for senior living facilities
Detailing guide for senior living facilities Creating an integrated system with Altro flooring and wall cladding is an ideal solution for areas in which hygiene and water resistance are a top concern.
More informationFood Code References on the Food Establishment Inspection Report
Supervision 1. PIC present, demonstrates knowledge, and performs duties 2-101.11 Assignment 2-102.11(A), B) and (1), (4)-(16) Demonstration 2-103.11 (A)-(O) Person-In-Charge-Duties 2. Certified Food Protection
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationFACILITIES CRITERIA (FC) NAVY AND MARINE CORPS DINING FACILITIES
FACILITIES CRITERIA (FC) NAVY AND MARINE CORPS DINING FACILITIES APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED FACILITIES CRITERIA (FC) NAVY AND MARINE CORPS DINING FACILITIES Any copyrighted material
More informationAttachment 3 Statement of Work Statement PROJECT NUMBER MA DIRECTORATE OF PUBLIC WORKS FORT BRAGG, NORTH CAROLINA
Request for Task Order Proposal Number: Attachment 3 Statement of Work Statement PROJECT NUMBER MA-00006-15 DIRECTORATE OF PUBLIC WORKS FORT BRAGG, NORTH CAROLINA PROJECT TITLE: Restore one Men s and one
More informationGENERAL INSTALLATION GUIDELINES
GENERAL INSTALLATION GUIDELINES VIEW ACTIS HYBRID VIDEOS ON General information HYBRIS is an insulation material generally used for roof, wall, ceiling and suspended timber floor applications. HYBRIS is
More informationCONSTRUCTION OF HOUSES WITH ACCESSIBILITY FACILITIES FOR PERSONS WITH DISABILITIES
CONSTRUCTION OF HOUSES WITH ACCESSIBILITY FACILITIES FOR PERSONS WITH DISABILITIES Introduction When constructing houses, it is important to design them with simple designs to enable persons with disability
More informationDrug Store Registration Audit Checklist
S.N. Specifications Article No. in the pharmacy law of 1983 Federal Decrees, Circular No. or International Standards (GPP,GSP,GDP) Requirements are met Requirements are not met Remarks 1 A registered pharmacist
More informationFacility Design for Pharmacy Operation. Full-Scale Nuclear. Slides are not to be reproduced without permission of author.
Facility Design for Pharmacy Operation Full-Scale Nuclear in a Hospital Setting Neil A. Petry, MS, RPh, BCNP, FAPhA Clinical i l Assistant t Professor in Radiology Director, Radiopharmacy Services Duke
More informationARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE
ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE MANNINGTON COLORFIELDS SHEET RUBBER FLOORING Section 09 65 16 Sheet rubber Flooring (Thermoset Rubber) Created May 2012 Mannington Mills, Inc. P. O. Box
More informationEncapsulated, Sealed & Closed Crawlspace Installation Manual
YourCrawlSpace, Inc. 1007 Johnni4 Dodds Blvd. Mt. Pleasant, SC 29464 Toll Free: 877-44-CRAWL (27295) Local: (843) 593-1115 Encapsulated, Sealed & Closed Crawlspace Installation Manual Copyright 2017 Your
More informationW i s d o m S m a r t C o l l e c t i o n. Newton series
W i s d o m S m a r t C o l l e c t i o n Newton series 9160mm Newton 18 Area Calculations Itemised Floor Areas Area Ground Floor 141.98 sqm 21.56 sqm Porch 2.27 sqm 165.81 sqm 17.7 sq Optional Alfresco
More informationfirst flush water diverters water quality first downspout, post/wall mounted and in-ground diverters
water quality first downspout, post/wall mounted and in-ground diverters Available in kit form just add PVC pipe Simple, effective and easy to install Includes Slow Release Control Valve - empties after
More informationACBC Floor Mounted Active Beam
Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More information8.7 PSYCH PREFERRED MANUFACTURER LIST
2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 8.7 PSYCH PREFERRED MANUFACTURER LIST This list is a compilation of products that have proven successful on Michigan
More information