PG 123 TM Framing 1. Optional Features Optional vertical covers 1/4" (6.4) infill adaptors
|
|
- Alexander Brooks
- 6 years ago
- Views:
Transcription
1 JNURY, 0 E 99-0 PG TM Framing FETURES Features Structural silicone glazed - captured head and sill cans IsoWeb TM thermal barrier (glass reinforced nylon) " (.) infill system Dual finish capability Rain screen Screw Spline joinery Square cut corners (no miters, no notching) Stock length or factory fabricated Pre-glazed / pre-assembled construction Installed from the interior +/- /" (.) live load deflection Permanodic TM anodized finishes in seven choices Painted finishes in standard and custom choices Optional Features Optional vertical covers /" (.) infill adaptors Kawneer ompany, Inc., 00 Product pplications Ribbon windows Multi-lite punched openings For specific product applications, onsult your Kawneer representative.
2 PG TM Framing LNK PGE JNURY, 0 E 99-0 Kawneer ompany, Inc., 00
3 JNURY, 0 E 99-0 PG TM Framing INDEX rchitects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. PITORIL VIEW... SI FRMING DETILS... MISELLNEOUS FRMING... WIND LOD HRTS..., 8 DEDLOD HRTS... 8 END RETION HRTS... 9 THERML HRTS Kawneer ompany, Inc., 00 LWS ND UILDING ND SFETY ODES GOVERNING THE DESIGN ND USE OF GLZED ENTRNE, WINDOW, ND URTIN WLL PRODUTS VRY WIDELY. KWNEER DOES NOT ONTROL THE SELETION OF PRODUT ONFIGURTIONS, OPERTING HRDWRE, OR GLZING MTERILS, ND SSUMES NO RESPONSIILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m meter cm centimeter mm millimeter s second Pa pascal MPa megapascal
4 PG TM Framing PITORIL VIEW JNURY, 0 E 99-0 SSG OPTIONL PPLIED OVER Kawneer ompany, Inc., 00
5 JNURY, 0 E 99-0 PG TM Framing SI FRMING DETILS SLE " = '-0" -/" (.) " (.) Kawneer ompany, Inc., 00 -/" (.)
6 PG TM Framing MISELLNEOUS DETILS JNURY, 0 E 99-0 SLE " = '-0" 90 o ORNERS INSIDE o ORNERS OUTSIDE OUTSIDE INSIDE /" DPTOR T SPNDREL RE Kawneer ompany, Inc., 00 SILL SSG JM
7 JNURY, 0 E 99-0 PG TM Framing WIND LOD / DED LOD HRTS WIND LOD HRTS Mullions are designed for deflection limitations in accordance with M TIR- of L/ up to '-" and L/0 +/" above '-". These curves are for mullions WITH HORIZONTLS and are based on engineering calculations for stress and deflection. llowable wind load stress for LUMINUM, psi (0 MPa), STEEL 0,000 psi (0 MPa). harted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0. per SE/SEI. / increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEDLOD HRTS Horizontal or deadload limitations are based upon /8" (.) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying chart is calculated for " (.) thick glass supported on two setting blocks placed at the loading points shown. Kawneer ompany, Inc., 00
8 8 PG TM Framing WIND LOD HRTS JNURY, 0 E 99-0 These charts are based on lateral support no more than " apart. Lateral support can be horizontal mullions or lateral buckling clips*. Mullions are designed for L/ deflection limitation. These curves are for mullions WITH or WITHOUT HORIZONTLS and are based on engineering calculations for stress and deflection. llowable wind load stress for LUMINUM, psi (0 MPa), STEEL 0,000 psi (0 MPa). harted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon normal wind load utilized in allowable stress design. conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0. per SE/SEI. / increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information WITH HORIZONTLS. E D WIDTH IN FEET (with 800 Mullion lips) WITHOUT HORIZONTLS. E D WIDTH IN FEET WITH HORIZONTLS. E D llowable Stress Design Load LRFD Ultimate Design Load = 0 PSF (90) PSF (80) = 0 PSF (0) 0 PSF (00) = 0 PSF (90) PSF (00) D = 0 PSF (00) 8 PSF (000) E = 0 PSF (880) 00 PSF (90) (with /8" x " STEEL R and 800 Mullion lips) 0 WITHOUT HORIZONTLS 9 8. E D Kawneer ompany, Inc., 00 WIDTH IN FEET WIDTH IN FEET *Engineering interpretation of lateral brace points may vary. Verify the acceptance of lateral buckling clips with project specifications, applicable building codes or consulting engineer, if applicable.
9 JNURY, 0 E 99-0 PG TM Framing 9 WIND LOD / DEDLOD HRTS WIND LOD HRTS Mullions are designed for L/ deflection limitations. These curves are for mullions WITHOUT HORIZONTLS and WITHOUT LTERL UKLING LIPS and are based on engineering calculations for stress and deflection. harted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon normal wind load utilized in allowable stress design. conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0. per SE/SEI. / increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. llowable Stress Design Load LRFD Ultimate Design Load = 0 PSF (90) PSF (80) = 0 PSF (0) 0 PSF (00) = 0 PSF (90) PSF (00) D = 0 PSF (00) 8 PSF (000) E = 0 PSF (880) 00 PSF (90) (With "No" Lateral uckling lips) WITHOUT HORIZONTLS. E D WIDTH IN FEET DEDLOD HRTS Kawneer ompany, Inc., 00 Horizontal or deadload limitations are based upon /8" (.) maximum allowable deflection at the center of an intermediate horizontal member. The accompanying chart is calculated for " (.) thick glass supported on two setting blocks placed at the loading points shown = / POINT LODING = / POINT LODING = /8 POINT LODING WIDTH IN FEET
10 0 PG TM Framing END RETION HRTS JNURY, 0 E WITH HORIZONTLS. E D WIDTH IN FEET llowable Stress Design Load LRFD Ultimate Design Load = 0 PSF (90) PSF (80) = 0 PSF (0) 0 PSF (00) = 0 PSF (90) PSF (00) D = 0 PSF (00) 8 PSF (000) E = 0 PSF (880) 00 PSF (90) WITHOUT HORIZONTLS 9 8. D E For applications beyond limitations of the above charts, nchor lips (800) are required Kawneer ompany, Inc., 00
11 JNURY, 0 E 99-0 PG TM Framing THERML HRTS Generic Project Specific U-factor Example alculation (Percent of Glass will vary on specific products depending on sitelines) (ased on single bay of Window Wall) '-0" D.L.O. '-0" D.L.O. '-0" D.L.O. Example Glass U-Factor = 0. Total Daylight Opening Total Projected rea '-8" F.W. tu/hr ft F = (' x ') + (' x ') = ft = (Total Daylight Opening + Total rea of Framing System) = '-8" x 9'-" = 8.8 ft 9'-" F.H. Percent of Glass = (Total Daylight Opening Total Projected rea) = ( 8.8)00 = 9% System U-Factor vs Percent of Glass rea 0.80 Kawneer ompany, Inc., 00 OG U-Factor EXMPLE (NOT FOR DESIGN) System U-Factor (TU/hr/ft / F) % Vision rea /Total rea % 0 ased on 9% glass and center of glass U-Factor of 0. System U-Factor is equal to 0.9 tu/hr ft F
12 PG TM Framing THERML HRTS Note: Values in parentheses are metric. OG = enter of Glass. harts are generated per MM 0 JNURY, 0 E 99-0 Kawneer ompany, Inc., 00
13 JNURY, 0 E 99-0 PG TM Framing THERML HRTS Kawneer ompany, Inc., 00
14 PG TM Framing THERML PERFORMNE MTRIX (NFR SIZE) JNURY, 0 E 99-0 Thermal Transmittance (TU/hr ft F) Glass U-Factor Overall U-Factor " GLZING WITH LUMINUM PRESSURE PLTE NOTE: For glass values that are not listed, linear interpolation is permitted.. U-Factors are determined in accordance with NFR 00.. SHG and VT values are determined in accordance with NFR 00.. Glass properties are based on center of glass values and are obtained from your glass supplier.. Overall U-Factor, SHG, and VT Matricies are based on the standard NFR specimen size of,000 mm wide by,000 mm high (8-/" by 8-/"). SHG Matrix Glass SHG Overall SHG Visible Transmittance Glass VT Overall VT Kawneer ompany, Inc.,
JULY, 2016 E.C
JULY, 06 E.. 979-0 Architects - These concepts have been expanded and modified to afford you design freedom. Please contact your Kawneer representative for further assistance. The extrusions and window
More informationTMS 114 XT TECHNICAL MANUAL
TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES is center set flush glazed systems that are 4 1/2" deep with a 2" wide sightline Glaze from the outside or inside Screw spline or shear block fabrication Glazing
More informationSeries 510-I Thermal Heavy Commercial Projected Window
Windows Curtain Walls Entrances Storefronts Series 510-I Thermal 2-7 16 Heavy Commercial Projected Window Configurations Project-In Project-Out Casement Fixed Series 510-I retains an AAMA Architectural
More informationTMS 152 / 152T / 152XT TECHNICAL MANUAL
TMS 152 / 152T / 152XT TECHNICAL MANUAL BLANK PAGE FEATURES FEATURES TMS 152 (non-thermal), 152T (single thermal barrier), and 152XT (double thermal barrier) are front set flush glazed systems that are
More informationArchitectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.
Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT Report Number: C0271.01-450-44 Rendered to: Tubelite Inc. Walker, Michigan MODEL DESIGNATION: 400 Series Curtainwall with 4 Sided SSG PRODUCT
More informationANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.
ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT Rendered to: MASTER WINDOW SYSTEMS, INC. SERIES/MODEL: Master 1000 Sliding Window PRODUCT: PVC Horizontal Sliding Window Summary of Results Title Test Specimen
More informationSWING DOOR SPECIFICATION
SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified
More informationSeries 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window
Windows Curtain Walls Entrances Storefronts Series 3500 Thermal Series 3900 Fixed Thermal 3 1 4 rchitectural Grade Horizontal Sliding Window Configurations X X XX X XX Fixed Series 3500 retains an M rchitectural
More informationSeries 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window
E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE BLAST GRADE Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** 3 7 8 Heavy Commercial Hung Thermal Window
More informationDesigning Glass to Resist Wind and Snow Loads
One of the design requirements of glass used in buildings is to resist the loads created by wind and snow. ASTM E1300-02: Standard Practice for Determining Load Resistance of Glass in Buildings provides
More informationTR-700 Window Wall. Multifaceted Window System for Flexible Design
TR-700 Window Wall Multifaceted Window System for Flexible Design The Admiral at the Lake, Chicago, Illinois, USA Architect: Perkins + Will, Dallas, Texas, USA Window Installer: Softer Lite Window Company,
More informationE-Wall System 5800, 5800-I
Windows Curtain Walls Entrances Storefronts E-Wall System 5800, 5800-I The beauty of EFCO s E-Wall Silicone Gasket curtain wall system is the simplicity in which it is installed. There are no internal
More informationEFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs
EFFECTIVE JULY, 2010 TRIFAB VG 451/451T 1 EC 97909-19 08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 RELATED
More informationTEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window
TEST REPORT Report No.: D8932.01-301-44 Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-08,
More informationArchitectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION
Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division
More informationThe Aluminum Framed Monumental Folding/Paired Panel System
INTRODUCTION SL45 The Aluminum Framed Monumental Folding/Paired Panel System The SL45 is a monumental, standard aluminum folding or paired panel system. As a folding system, it is designed to provide an
More informationSeries Heavy Commercial Projected Window
Windows Curtain Walls Entrances Storefronts Series 510 2-7 16 Heavy Commercial Projected Window Configurations Project-In Project-Out Casement Pivot Top-Hinged Fixed Series 510 retains an AAMA Architectural
More informationGUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM
1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY
More informationProject: North Charleston City Hall, North Charleston, SC
0- ALUINU Table of Contents STOR WALL Series IW50 SECTION PAGE SPECIFICATIONS...0- and 0- TECHNICAL DATA...04- SPECIAL FEATURES...05- TYPICAL DETAILS FOR 7/6" () GLAZING...06- TYPICAL DETAILS FOR -/6"
More informationBlast Curtain Wall Installation Analysis
August 11, 2005 57402.01-122-34 JAR/STS 1 US Aluminum BR3250 Blast C.W. Blast Curtain Wall Installation Analysis Subject: BR3250 Blast Curtain Wall System ATI Report 57402.01-122-34 Rendered to: International
More informationSignature Series 5 Lap SECTION ALUMINUM WINDOWS
Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this
More informationALUMINUM (800) (866) BLAST MITIGATION. BR604/BR606/BT601 Storefront BR7500/BW7600/BW8000 BW8100/BW8200 Windows Accessory Hardware
BLAST MITIGATION BR60/BR606/BT601 Storefront BR700/BW7600/BW8000 BW8/BW800 Windows Accessory Hardware Toll ree Phone Service (800) 6-11 Toll ree ax Service (866) 6-99 U.S. and Canada usalum.com BLAST MITIGATION
More informationBEARING METAL STUD FRAMING
L-1 Section 05410 Long Form Specification LOAD BEARING METAL STUD FRAMING This section includes axially loaded steel studs, with unique slotted top channels, usually of 0.91, 1.2 and 1.5 mm (16, 18, or
More informationYES SSG TU Vent Window System
YES SSG TU VENT SYSTEM DESCRIPTION 3-1/2" Overall Depth Flat and Pocket Frame Options Variations: Casement Outswing Projected Outswing 1" Glazing Optional Screens YES SSG TU VENT PERFORMANCE FEATURES AAMA/WDMA/CSA
More informationTEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio
Architectural Testing TEST REPORT Report No.: B2739.02-501-47 Rendered to: TREMCO, INCORPORATED Beachwood, Ohio PRODUCT TYPE: Air Barrier System SERIES/MODEL: ExoAir 230, ProGlaze ETA System 1, Spectrem
More information6110 Horizontal Sliding Windows
6110 Horizontal Sliding Windows Half-vent Half-vent below Half-vent above Single-vent HALF-VENT - Min 2 0 1 0 Max 6 0 5 0 HALF-VENT ABVE - Min 2 0 2 0 Max 6 0 6 0 HALF-VENT BELW - Min 2 0 2 0 Max 6 0 6
More informationMASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
More informationArchitectural Systems for Building Facades. Leader and Expert in High Performance Curtain walls systems
Architectural s for Building Facades Leader and Expert in High Performance Curtain walls systems STEKAR CURTAIN WALLS SYSTEMS Definition: A SYSTEM IS A SET OF ELEMENTS THAT INTERACT WITH ONE ANOTHER ACCORDING
More informationCustom fabrication in two weeks or less, guaranteed.
Custom fabrication in two weeks or less, guaranteed. Ask us how Ramco can now fabricate hardware on all manufacturers blank doors in 2 weeks or less. ramcometals.com got lead times? Ramco offers custom
More informationPW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall
Manufacturer: Coral Architectural Products 3010 Rice Mine Road Tuscaloosa, AL. 35406 Voice: (800) 772-7737 Fax: (800) 443-6261 SECTION 08900 ALUMINUM CURTAIN WALL This suggested guide specification has
More informationEME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER MIAMI-DADE APPROVED MIAMI-DADE COUNTY, FLORIDA NOTICE OF ACCEPTANCE NUMBER:
More informationGold Bond BRAND Gypsum Sheathing
BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant
More informationSL35 Introduction. NanaWall SL35 The Standard Aluminum Framed Folding System
SL35 Introduction NanaWall SL35 The Standard Aluminum Framed Folding System The SL35 is an aluminum folding panel system designed to provide a moving glass wall for openings as wide as 39. It is a top-hung
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1114 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 07 00
More informationSPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
More informationSECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.
1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation
More informationBuilt to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames
Frames Section Contents General Frame Construction Profiles F-1.0 Typical Jamb & Sill Profiles F-2.0-2.1 Frame Welding Elevations F-3.0 Frame Elevations F-4.0-4.2 Custom Frame Elevations Panel Types +
More informationSECTION 1043 FENCE MATERIAL
SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance
More informationT700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)
T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) FEATURES 1.) Available Configurations -Single hung -Oriel style (optional) 2.) Main frame / Sash -Drop-in glazing
More informationGuideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
More informationSAVANNAH TRIMS st STREET N., SUITE 4 LAKE PARK, FLORIDA
M.O. R.O. F.S. A.F.F. STL ALUM HORIZ VERT ELEV. N.T.S. G.. ARH. P.S.F. REQ'D TYP. ABBREVIATIONS MASONRY OPENING ROUGH OPENING FRAME SIZE DAYLIGHT OPENING ABOVE FINISHED FLOOR STEEL ALUMINUM HORIZONTAL
More informationGUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM
1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00
More informationEDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
More informationVinyl Windows and Doors
Install Atrium 0UZ[PSS *VUÄKLUJL Vinyl Windows and Doors Atrium Vinyl Windows A Commitment to Excellence Since 1948 Welcome the beauty of The Vinyl Advantage Vinyl is the ideal material for engineering
More informationICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015
ICC-ES Evaluation Report ESR-1694 Reissued March 2014 This report is subject to renewal March 1, 201 www.icc-es.org (800) 423-687 (62) 699-043 A Subsidiary of the International Code Council DIVISION: 07
More informationAwning Windows Montecito New Construction Window
Awning Windows Montecito New Construction Window Full awning Double-top awning Double awning Double-bottom awning FULL DOUBLE BOTTOM/TOP DOUBLE AWNING - Min 1 3 1 4 Max 4 6 3 0 AWNING - Min 3 0 1 6 Max
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationCasement Windows Montecito New Construction Window
Casement Windows Montecito New Construction Window Full casement Double-bottom casement FULL DOUBLE/SINGLE DOUBLE CASEMENT - Min 1 6 1 0 Max 3 0 5 0 or 2 6 6 0 CASEMENT - Min 3 0 1 6 Max 6 0 5 0 or 5 0
More informationThe Alternative to Storefront. Gerkin Model 58F
The Alternative to Storefront Gerkin Model 58F Why do we need an alternative? To provide windows with factory glazing To eliminate water leaks To eliminate the need for sill flashing w/ end dams To reduce
More information6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing
6 Drainable Louver Section Page Number Catalogue Page 2 Page 7 Performance Data Page LP-12 Page LP-13 Submittals Drawing 237947 Update to Louvers Catalog C-1.0 April 2010 Louvers General Product Overview
More information7520 Casement Windows
Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum
More informationSECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove
Duo-Gard Industries Inc. 40442 Koppernick Road Canton, Michigan 48187 Phone (734) 207-9700 Fax (734) 207-7995 www.duo-gard.com SECTION 08 45 13 Structured Polycarbonate Panel Assemblies Series 3500 BPC
More informationESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drain gutters in the head
More information3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows
3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows 3000 SERIES FIBERGLASS - Min 1 6 2 9 Max 4 0 7 0 - Min 3 0 2 9 Max 8 0 7 0 Double-Hung Double Double-Hung - Min 4 6 2 9 Max 12 0 7 0 Minimum
More informationThe TKI success kit. The excellently thought-out aluminium profi le system for windows, doors and façades.
The TKI success kit The excellently thought-out aluminium profi le system for windows, doors and façades. Presented by MKF Metallbaukontor Frankfurt GmbH More than 40 years of excellent system engineering
More informationESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver Drainable Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More informationASD OF CONCRETE MASONRY LINTELS BASED ON THE 2012 IBC/2011 MSJC. TEK 17-1D Structural (2011) Related TEK: 14-7C, 14-13B, 17-1C, 17-2A
n information series from the national authority on concrete masonry technology SD OF CONCRETE MSONRY LINTELS BSED ON THE 2012 IBC/2011 MSJC TEK 17-1D Structural (2011) INTRODUCTION Lintels and beams are
More informationDIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS
DIVISION 8 OPENINGS SECTION 08 51 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information4-5/8" Offset Projected Architectural Thermal Aluminum Windows. Project In TR-740 (AW-PG80-AP) or Project Out TR-750 (AW-PG80-AP)
4-5/8" Offset Projected Architectural Thermal Aluminum Windows Project In TR-740 (AW-PG80-AP) or Project Out (AW-PG80-AP) TR-700 Window Wall Multifaceted Window System for Flexible Design The Admiral at
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1015 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 07 00
More informationSPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT
SPECIFICATION GUIDE SLIDING CLOSET DOOR INTERIOR SLIDING GLASS DOOR PART 1 - PRODUCT 1.1 MANUFACTURER A. COXUSA 4755 E. Zinfandel Court, Suite D Ontario, California 91761 909.545.8900 eddie.coxusa@icloud.com
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3435 Reissued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationNanaWall HSW60 - Thermally Broken Aluminum Framed Single Track Sliding System
TABLE OF CONTENTS HSW60 NanaWall HSW60 - Thermally Broken Aluminum Framed Single Track Sliding System Introduction................................................................................1 Technical
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationDIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC.
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3505 Issued 04/2017 This report is subject to renewal 04/2018. DIVISION: 10 00 00 SPECIALTIES
More informationYCW 250 I-Beam Curtain Wall System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS INSTALLATION NOTES..................................... Page ii PARTS DESCRIPTION Framing
More informationEDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Stationary Louver K Blade is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates drainable head, K style blades,
More informationField Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector
mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40)799-4200 Main Runner with
More informationA typical structural glazing system is composed of a number of essential components:
DESIGN COMPONENTS FOR STRUCTURAL GLAZING A typical structural glazing system is composed of a number of essential components: 1. Structural framing or support structure 2.!Glass! 3. Structural silicone
More informationDuracast Pressure Plate Installation Instructions
July 2015 EFCO CORPORATION 7/2015 PART NO. YW45 1 TABLE OF CONTENTS SECTION S-5600 / S-5900 DURACAST PRESSURE PLATE PAGE I. General Notes and Guidelines. 3-4 II. Glazing Preparation & Installation... 5
More informationSERIES DESCRIPTION MODEL PAGE
Storm Window Index Exterior storm window features increased durability and ultimate thermal protection. Performance Exterior storm window offers more standard features than other storm windows on the market.
More informationPRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW
08 46 3 GLAZED ALUMINUM WINDOW WALL PART - GENERAL A high-quality thermally broken 4 ½ aluminum window wall designed for residential high rise construction.. SUMMARY A. Section Includes: Glazed Aluminum
More informationESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)
Application and Design Thin-line Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth
More informationArchitects and Designers Should Understand Loads Exerted By Rolling Doors
rchitects and Designers Should Understand Loads Exerted y Rolling Doors It is important for architects and building designers to understand the loads that rolling doors exert on the wall above the opening
More informationCentral Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS
Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society
More informationAN ARCHITECT S GUIDE TO NAFS USING THE NORTH AMERICAN FENESTRATION STANDARD IN CANADA
AN ARCHITECT S GUIDE TO NAFS USING THE NORTH AMERICAN FENESTRATION STANDARD IN CANADA MAY 2017 Al Jaugelis, B.Sc.Arch. The material provided in this guide is for information and suggestion only. The greatest
More informationPicture/Radius Windows Montecito New Construction Window
Picture/Radius Windows Montecito New Construction Window Picture window Half-round Round?top/picture Picture?window gable Picture?window octagon Quarter?Round Round?top PICTURE WINDOW - Min 1 6 1 6 Max
More informationNanaWall Matching Windows and Doors Table of Contents
NanaWall Matching Windows and Doors Table of Contents Matching Windows and Doors Cross Sections and Maximum Frame Charts Introduction.............................................................. 1 NanaWall
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationINSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1" TRIM OFFICE PARTITIONS
INSTALLATION INSTRUCTIONS SRIS 87 CNTR GLAZD WITH 1" TRIM OFFIC PARTITIONS Phone: (800) 21-61 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M020 HANDLING, STORAG, AND PROTCTION OF The following
More informationAlply CLASSIC WALL Architectural Insulated Panel Wall System
SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationAQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals
AQUARIUS CONDOMINIUM 2751 SOUTH OCEAN DRIVE HOLLYWOOD, FLORIDA 33019 40 YEAR RESTORATION PROJECT & RELATED WORK Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals ENGINEER S PROJECT # 7478-16
More informationU-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report
U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 5/25/2016 REPORT DATE: 6/2/2016 Client: Product Line: Specification:
More informationDIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 97 Reissued /7 This report is subject to renewal /8. DIVISION: 05 00 00 METALS SECTION:
More information5.0 Daylighting Analysis (Breathe Study)
5.0 Daylighting Analysis (Breathe Study) 69 5.0 Daylighting Analysis (Breathe Study) 5.1 Background contains approximately 150 patient recovery rooms. Of these 96 are located around the perimeter of the
More informationMODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS
MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes
More informationFully framed glass panels
Fully framed glass panels design elements G1 Fully framed glass panels G1 design The G1 is a fully framed balustrade solution suiting a refined and deliberate architectural style. Rather than minimising
More informationSliding Patio Doors Brickmould Vinyl
TABLE OF CONTENTS Specifications... 7-2 QuickSpecGuide... 7-3 Elevations/Sizes: 1/8 Scale 2-WideSlidingPatioDoors... 7-4 GlazingOptions: 3 Scale... 7-5 Grille Patterns... 7-6 SectionDetails: 6 Scale...
More informationSTOREFRONT, CURTAINWALL & ENTRANCES
2007 STOREFRONT, CURTAINWALL & ENTRANCES 14.02 14000 Series Flush Glaze Guide Specifications General Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2937 Reissued 05/2016 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL
More informationREBCO ALUMINUM WINDOWS
REBCO ALUMINUM WINDOWS When you are looking for the perfect windows to enhance your building's facade, you can count on REBCO's experienced staff to assist you with product selection and design as well
More informationVeka Evolutions Commercial Window Program
interior/exterior accessory grooves aluminum reinforcement galvanized steel reinforcement Veka Evolutions Commercial Window Program VEKA Inc. is proud to introduce the Evolutions line of commercially rated
More informationThermal Bridging and Whole Building Energy Performance
Thermal Bridging and Whole Building Energy Performance Steve Murray, P.Eng. PMP Morrison Hershfield May 8 & 9, 2013 1 Acknowledgments The real work for ASHRAE 1365 RP was done by others in MH s Vancouver
More informationELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM
RUSKIN 3900 Dr. Greaves Rd. Grandview, MO 64030 (816) 761-7476 FAX (816) 966-1655 ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM STANDARD CONSTRUCTION FRAME 6 (152) deep, 6063T5 extruded aluminum
More information3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.
1 General This glazing specification outlines the general considerations for glazing as used in security glazing applications (ballistic, bomb blast and burglary resistance). 2 Materials Minimum requirements
More informationDesign Manual and Catalog of Steel Deck Products STEEL DECK INSTITUTE MEMBER
Design Manual and Catalog of Steel Deck Products s STEEL DECK INSTITUTE MEMBER Manufacturers of products History CMC Joist & Deck is a leading producer of steel deck, open-web steel joists, long span steel
More information