COMcheck Software Version Interior Lighting Compliance Certificate

Size: px
Start display at page:

Download "COMcheck Software Version Interior Lighting Compliance Certificate"

Transcription

1 COMcheck Software Version Interior Lighting Compliance Certificate Project Information Energy Code: Project Type: 2012 IECC New Construction Construction Site: 224 First Ave Eaton, CO Additional Efficiency Package Owner/Agent: Designer/Contractor: Lawrence Smith SRB Consulting Engineering, LLC 312 Cullison Ridge Rd Windsor, CO Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Municipal Rooms (Courthouse) Total Allowed Watts = 4169 Proposed Interior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) 1-Municipal Rooms (Courthouse) LED 1: A: 6" LED Recessed Can: Other: LED 2: B: 4" LED Recessed Can: Other: LED 3: C: 4' LED Strip Light: Other: LED 4: D: 2x4 Volumetric Troffer: Other: LED 5: E: Decorative LED Pendant: Other: LED 6: F: 6" LED Wall Washer: Other: LED : G23: 23' LED Tape Light: Other: LED 8: P16: 16' LED Direct/Indirect Pendant: Other: Track lighting 1: T8: 8' Track, LED Heads, 60W Limite: Wattage based on current limiting device capacity Track lighting 2: T12: 8' Track, LED Heads, 60W Limite: Wattage based on current limiting device capacity Linear Fluorescent 1: (E): Existing 2x4, 3-Lamp Parabolic: 48" T8 32W: Electronic: Linear Fluorescent 2: (R): Relocated 2x4, 3-Lamp Parabolic: 48" T8 32W: Electronic: Linear Fluorescent 3: (R): Relocated 8' Strip: 48" T8 32W: Electronic: Total Proposed Watts = of

2 Interior Lighting PASSES: Design 2% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date 2 of

3 COMcheck Software Version Inspection Checklist Energy Code: 2012 IECC Requirements: 6.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.ID C103.2 [PR4] 1 C406 [PR9] 1 Plan Review? Comments/Assumptions Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) 3 of

4 Section # & Req.ID 1 [EL22] 2 C [EL23] 2 C [EL15] 1 3 [EL16] 2 C [EL1] 3 2 [EL18] 1 3 [EL20] 1 3 [EL21] 1 C [EL4] 1 C405.3 [EL19] 3 C405.4 [EL6] 1 C [EL8] 1 Rough-In Electrical Inspection? Comments/Assumptions Automatic controls to shut off all building lighting installed in all buildings. Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Lighting controls installed to uniformly reduce the lighting load by at least 50%. Daylight zones provided with individual controls that control the lights independent of general area lighting. Sleeping units have at least one master switch at the main entry door that controls wired luminaires and switched receptacles. Occupancy sensors installed in required spaces. Primary sidelighted areas are equipped with required lighting controls. Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Separate lighting control devices for specific uses installed per approved lighting plans. Fluorescent luminaires with odd numbered lamp configurations that are within 10 feet center to center (if recess mounted) or are within 1 foot edge to edge (if pendant or surface mounted) shall be tandem wired. Exit signs do not exceed 5 watts per face. Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Additional Comments/Assumptions: Exception: Lighting controlled by occupancy sensors. Exception: Areas that are controlled by an occupancy sensor. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) 4 of

5 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) 5 of

6 Section # & Req.ID C [FI16] 3 C303.3, C [FI1] 3 Final Inspection? Comments/Assumptions Furnished as-built drawings for electric power systems within 30 days of system acceptance. Furnished O&M instructions for systems and equipment to the building owner or designated representative. C [FI18] 1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. See the Interior Lighting fixture schedule for values. C408.3 [FI33] 1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) 6 of

7 of

Compliance Certificate

Compliance Certificate REScheck Software Version 4.6.4 Compliance Certificate Project RESIDENCE Energy Code: 2009 IECC Location: Perkasie, Pennsylvania Construction Type: Single-family Project Type: New Construction Conditioned

More information

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST ENVELOPE REQUIREMENTS Project: Date: Instructions RECOMMENDED: List performance values, note exceptions that were applied, or provide other

More information

new equipment & construction

new equipment & construction Note: All fluorescent fixtures must have High formance or Reduced Wattage (HP/RW) lamps & ballast systems or a T5 lamp and ballast systems to be eligible for a fluorescent incentives. Facility lighting

More information

Compliance Certificate

Compliance Certificate REScheck Software Version 4.6.2 Compliance Certificate Project Sample Energy Code: 2012 IECC Location: Coeur d'alene, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor

More information

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2) MANDATORY MEASURES CONTROLS (Reference: Sub-Chapter 4, Section 130.2) BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS The BUG system is used to evaluate luminaire performance in relation to lighting trespass,

More information

Compliance Certificate

Compliance Certificate REScheck Software Version 4.6.3 Compliance Certificate Project Energy Code: 2012 IECC Location: Frederick, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area:

More information

LIGHTING TECHNICAL SHEET

LIGHTING TECHNICAL SHEET GENERAL INFORMATION LIGHTING TECHNICAL SHEET SMECO's Business Solutions program is designed to help commercial and industrial customers maximize energy efficiency and manage energy costs. With cost-saving

More information

REScheck Software Version Compliance Certificate

REScheck Software Version Compliance Certificate REScheck Software Version 4.3.1 Compliance Certificate Project Title: Chow Residence Renovation Energy Code: 2009 IECC Location: Boston, Massachusetts Construction Type: Single Family Project Type: Addition/Alteration

More information

BUILDING LIGHTING Modeling Requirements Appendix G. 1 Exceeding Standard ASHRAE Learning Institute

BUILDING LIGHTING Modeling Requirements Appendix G. 1 Exceeding Standard ASHRAE Learning Institute BUILDING LIGHTING Modeling Requirements 90.1-2007 Appendix G 1 Exceeding Standard 90.1-2007 2003-2008 ASHRAE Learning Institute Appendix G: Modeling Requirements Lighting - Proposed Design Lighting System

More information

Bulbs and Ballast. Regular Product : Bulbs and Ballast

Bulbs and Ballast. Regular Product : Bulbs and Ballast Bulbs and Ballast Bulbs and Ballast Bulbs and Ballast Rating: Not Rated Yet Ask a question about this product Description In the past decade, tremendous advances have been made in the efficiency of virtually

More information

NONRESIDENTIAL LIGHTING Key Changes to mandatory and prescriptive lighting requirements in California s 2016 Building Energy Efficiency Standards

NONRESIDENTIAL LIGHTING Key Changes to mandatory and prescriptive lighting requirements in California s 2016 Building Energy Efficiency Standards LIGHTING BEST PRACTICES WHAT S NEW IN THE 2016 CODE? NONRESIDENTIAL LIGHTING Key Changes to mandatory and prescriptive lighting requirements in California s 2016 Building Energy Efficiency Standards California's

More information

Light levels should be appropriate for the task and per the following guide in Part 1 - General.

Light levels should be appropriate for the task and per the following guide in Part 1 - General. DIVISION 16 - ELECTRICAL Section 16510 - Lighting Design Introduction Lighting utilizes approximately 40% of the electrical energy consumed here at the university. In order to conserve the energy it is

More information

Lighting Rebates 2017 New Construction Rebate Application

Lighting Rebates 2017 New Construction Rebate Application 2017 New Construction Rebate Application Business Member Information Business Name Installation Address City, State, Zip Contact Name Email Phone Number Account Number Application Check List Rebate application

More information

New Construction Lighting Application. Application Process. Details & Instructions

New Construction Lighting Application. Application Process. Details & Instructions New Construction Lighting Application Details & Instructions PSO provides technical assistance and rebates to assist businesses in making energy saving upgrades. Review details and requirements* at PowerForwardWithPSO.com.

More information

Rhode Island Commercial Codes FAQs

Rhode Island Commercial Codes FAQs Rhode Island Commercial Codes FAQs When does the new code go into effect? The new suite of building codes (including the new state energy conservation code, SBC-8) was adopted on July 1, 2013. A brief

More information

Lighting Calculator 3.3 Program Offerings

Lighting Calculator 3.3 Program Offerings Lighting Calculator 3.3 Program Offerings Series A: T8 Linear Fluorescent Series A covers both interior and exterior linear fluorescent lighting including 4, 8 T8 and irregular size products. A1-30% Linear

More information

Lighting and Daylighting for The 21 st Century School

Lighting and Daylighting for The 21 st Century School Lighting and Daylighting for The 21 st Century School James R Benya PE FIES IALD LC BENYA LIGHTING DESIGN Development funded by Acuity Brands and Finelite This program is registered with the AIA/CES for

More information

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building 2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building Building Department 52700 Van Dyke, Shelby Township, MI 48316 Phone (586) 731-5969 Fax (586) 803-2099 building@shelbytwp.org

More information

IECC Commercial Significant Changes Summary Tier I

IECC Commercial Significant Changes Summary Tier I 2009-2015 IECC Commercial Significant Changes Summary Tier I The first change is in the layout of the book. Instead of having Chapters 1-3 that applied to all projects and then having Chapter 4 Residential

More information

Increased Energy Savings with Advanced Lighting and Controls RESNET Building Performance Conference February 27 th, 2013

Increased Energy Savings with Advanced Lighting and Controls RESNET Building Performance Conference February 27 th, 2013 Increased Energy Savings with Advanced Lighting and Controls 2013 RESNET Building Performance Conference February 27 th, 2013 Lighting Power Densities & Calculate Energy Savings in Multifamily Projects

More information

SUMMARY OF SERVICES & INCENTIVES

SUMMARY OF SERVICES & INCENTIVES SMALL BUSINESS PROGRAM 2017 SUMMARY OF SERVICES & INCENTIVES Effective through December 31, 2017 Last updated February 1, 2017 EFFICIENCY INCENTIVES SUMMARY The Focus on Energy Small Business Program offers

More information

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street CITY OF ANDERSON BUILDING AND CODES 601 South Main Street Plan Review Notes (STREET ADDRESS) ANDERSON, SC Plan Review Number: Building Plans prepared by: Plans Signed by: Project Name: Plans Received:

More information

Retrofit Lighting Rebate Application. Application Process. Details & Instructions. Equipment Eligibility

Retrofit Lighting Rebate Application. Application Process. Details & Instructions. Equipment Eligibility Retrofit Lighting Rebate Application Details & Instructions PSO provides technical assistance and rebates to assist businesses in making energy saving upgrades. Review details and requirements* at PowerForwardWithPSO.com.

More information

National Electrical Manufacturers Association Guidance on Energy Policy Act Commercial Building s Tax Deduction Certification Letters.

National Electrical Manufacturers Association Guidance on Energy Policy Act Commercial Building s Tax Deduction Certification Letters. National Electrical Manufacturers Association Guidance on Energy Policy Act Commercial Building s Tax Deduction Certification Letters October 3, 2006 1 National Electrical Manufacturers Association Guidance

More information

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:

More information

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2008 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

Hardin County Planning and Development Commission

Hardin County Planning and Development Commission Location by Climate Zone: Hardin County (per Table N1101.2), and the entire state of Kentucky is located in Climate Zone 4, the HDD is 4000 to 4999. Building Requirements; Building Thermal Envelope The

More information

Duke Energy Corporation

Duke Energy Corporation Commercial Audit for Account: 12345-56789 Thank you for completing the Duke Energy Corporation Business Energy Check. We hope the information and recommendations provided will assist you in managing your

More information

LIGHTING DISTRIBUTOR INSTANT REBATE PROGRAM

LIGHTING DISTRIBUTOR INSTANT REBATE PROGRAM Lighting Distributor Instant Rebate Program Program Year 2016 (July 1, 2016 June 30, 2017) The Hawaii Public Utilities Commission has contracted with Leidos Engineering, LLC to administer the Hawaii Energy

More information

LED Applications. Presented for: Waste Reduction Partners. Presented by: Thomas D. Mull, PE, PEM, CEM Carolina Consulting Group, Inc.

LED Applications. Presented for: Waste Reduction Partners. Presented by: Thomas D. Mull, PE, PEM, CEM Carolina Consulting Group, Inc. Presented for: Waste Reduction Partners Presented by: Thomas D. Mull, PE, PEM, CEM Carolina Consulting Group, Inc. Interior Applications New & Retrofit Interior Applications New & Retrofit LED Benefits

More information

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE Changes to the Minnesota Commercial Energy Code Presented by: Andy Thielen, PE Warning! The following is an outline of proposed code changes. There is no guarantee that the final code adopted by the State

More information

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments Use of these instructions with a residential data collection

More information

Forum M: Top 10 Cost Reduction Strategies for Science Facility Operations and Maintenance

Forum M: Top 10 Cost Reduction Strategies for Science Facility Operations and Maintenance Forum M: Top 10 Cost Reduction Strategies for Science Facility Operations and Maintenance Forum M: Top 10 Cost Reduction Strategies for Science Facility Operations and Maintenance Presentation Outline

More information

TSR LIGHTING, ST PAUL, MN JEFF BOUMEESTER

TSR LIGHTING, ST PAUL, MN JEFF BOUMEESTER TSR LIGHTING, ST PAUL, MN JEFF BOUMEESTER LEAD THE LED LIGHTING REVOLUTION to obsolete energy-inefficient lighting. 2014 Cree, Inc. All rights reserved. 2 The Rising Cost of Lighting Lighting accounts

More information

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS Presented by: Shaunna Mozingo, Colorado Code Consulting WHAT CAN WE EXPECT TO SEE? Some consensus on enough is enough for now - No real roll backs, no real

More information

SECTION LUMINAIRES AND ACCESSORIES

SECTION LUMINAIRES AND ACCESSORIES SECTION 16500 LUMINAIRES AND ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to

More information

E3T Energy. Task/Vertical/Ambient Lighting. Emerging Technologies Showcase

E3T Energy. Task/Vertical/Ambient Lighting. Emerging Technologies Showcase 1 Task/Vertical/Ambient Lighting Showcase September 18, 2013 Presenters: Jerry Mix Finelite, Inc Kelly Cunningham California Lighting Technology Center Welcome. Today s webinar is being recorded and will

More information

Village of Glen Ellyn Basement Remodeling Project Guidelines

Village of Glen Ellyn Basement Remodeling Project Guidelines Village of Glen Ellyn Basement Remodeling Project Guidelines Existing unfinished basement space is often remodeled to create more habitable (living, sleeping, eating, dining) space in a home. Building

More information

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949) CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA 92691 (949) 470-3054 KITCHEN REMODELS A permit is required for kitchen remodels that include removal and replacement

More information

Lighting Rebates Rebate Application

Lighting Rebates Rebate Application Rebate Application Coop Logo Here Business Member Information Business Name Installation Address City, State, Zip Contact Name Email Phone Number Account Number Rebate Recipient To release the rebate incentive

More information

PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016

PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016 PacifiCorp s Planned Changes to wattsmart Business in Idaho May 2016 PacifiCorp is planning modifications to the wattsmart Business energy efficiency incentive program, which is offered through Schedule

More information

Bringing a little sunshine into our lives

Bringing a little sunshine into our lives Bringing a little sunshine into our lives Hybrid Solar Lighting K.L.C.N. Kumara chathurangaliyanage@hotmail.com Computing and Information System Sabaragamuwa University. 1 Hybrid Sola Lighting System Solution

More information

National Electrical Manufacturers Association

National Electrical Manufacturers Association National Electrical Manufacturers Association Guidance on 2005 Energy Policy Act (as modified in 2015) Commercial Building s Tax Deduction Certification Letters Revised April 14, 2016 National Electrical

More information

Boulder City NV Prepared by (Print Name) Signature Date

Boulder City NV Prepared by (Print Name) Signature Date City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy

More information

ANSI/ASHRAE/IESNA Standard /2001/2004 Energy Standard for Buildings Except Low-Rise Residential Buildings

ANSI/ASHRAE/IESNA Standard /2001/2004 Energy Standard for Buildings Except Low-Rise Residential Buildings ANSI/ASHRAE/IESNA Standard 90.1-1999/2001/2004 Energy Standard for Buildings Except Low-Rise Residential Buildings Larry Spielvogel, PE Past Chair Standard 90.1-1999/2001/2004 Developed jointly by the

More information

Emerging Lighting Technologies and Applications: Combining the New with the Tried and True

Emerging Lighting Technologies and Applications: Combining the New with the Tried and True Emerging Lighting Technologies and Applications: Combining the New with the Tried and True Karl Johnson, California Institute for Energy Efficiency Don Aumann, California Energy Commission Judie Porter,

More information

LIGHTING EQUIPMENT 2018 ILLINOIS FOR YOUR BUSINESS REBATE APPLICATION

LIGHTING EQUIPMENT 2018 ILLINOIS FOR YOUR BUSINESS REBATE APPLICATION LIGHTING EQUIPMENT 2018 ILLINOIS FOR YOUR BUSINESS REBATE APPLICATION Instructions: Fill out form completely and sign. Attach itemized invoices and supporting documentation, if applicable. Failure to complete

More information

Solano Community College District Lighting Standards

Solano Community College District Lighting Standards Solano Community College District Lighting Standards Prepared for: Solano Community College 4000 Suisun Valley Road Fairfield, CA 94534 FINAL SUBMITTAL 1-29-2016 Approved 3-16-16 by Board of Trustees Kitchell

More information

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16 JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16 Welcome! This course is designed to provide an overview of the most significant changes to the 2010 edition of the Florida

More information

HEALTHCARE & SCHOOL LIGHTING

HEALTHCARE & SCHOOL LIGHTING HEALTHCARE & SCHOOL LIGHTING Lighting & Control Solutions SLGUS.COM TD Recessed Troffer One Of The Best Value Low-Profile LED Luminaire Popular center-basket design features with an elegant design, shallow

More information

LATEST UPDATES TO TITLE 24 & TITLE 20 AUGUST 2017

LATEST UPDATES TO TITLE 24 & TITLE 20 AUGUST 2017 LATEST UPDATES TO TITLE 24 & TITLE 20 AUGUST 2017 IMPACTS OF LATEST UPDATES TO TITLE 24 & TITLE 20 Presented by: Chris Primous - VP of National Accts and Industry Relations, MaxLite California Title 24

More information

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other This information must be on the drawing documents not attached to plans. The following Compliance statements must be on the drawings: 2009 International Energy Conservation Code Statement of acknowledgement

More information

2016 Commercial Efficiency Program

2016 Commercial Efficiency Program Existing Building Rebate Application, Version 2.0 The Commercial Efficiency Program offers rebates to commercial, industrial, institutional, educational, municipal or multi-family building customers who

More information

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy.

STREET LIGHTING. Springville City Power standard street lights will be installed in accordance with Springville City Power's Line Extension Policy. General The following general requirements shall apply to street lights installed in new underground residential subdivisions or developments located within the service area of Springville City Power (within

More information

This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this

This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this sustainability standard 1 This presentation is protected. 2 This

More information

NC ECC Commercial Training June 2011

NC ECC Commercial Training June 2011 Mathis Consulting Company North Carolina Energy Conservation Code: Commercial Prescriptive Provisions Mathis Consulting Company Building Solutions Chris Mathis 100+ Years of Experience as Building Scientists,

More information

Designing with Energy-Efficient Lighting

Designing with Energy-Efficient Lighting Designing with Energy-Efficient Lighting Why Care? Why Care? Reducing energy use helps decelerate climate change by preventing greenhouse gas emissions As energy prices continue to rise, the importance

More information

Building Construction Occupations

Building Construction Occupations Job Ready Assessment Blueprint Building Construction Occupations Test Code: 2011 / Version 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Safety and General Knowledge

More information

the weidt group Implementation Rates of Energy Conservation Measures for Health Care Buildings collaboration analysis research

the weidt group Implementation Rates of Energy Conservation Measures for Health Care Buildings collaboration analysis research Implementation Rates of Energy Conservation Measures for Health Care Buildings the weidt group collaboration analysis research WWW.TWGI.COM HIGH PERFORMANCE BUILDINGS PAGE 1 THE WEIDT GROUP 2007 15 TH

More information

WARNING: Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component.

WARNING: Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component. WARNING! RISK OF FIRE OR ELECTRICAL SHOCK Disconnect power before installing or servicing. WARNING: Risk of fire or electrical shock. Luminaire wiring, power supply, or other electrical parts may be damaged

More information

IWF Safety Guidelines

IWF Safety Guidelines 2018 The purpose for the display rules and height restrictions is to provide visibility to all exhibitors. At the same time, these regulations should maintain the inherent benefits of differing exhibit

More information

Next Generation Lighting Systems Page 1 of INDOOR Competition Two Entrant Guide

Next Generation Lighting Systems Page 1 of INDOOR Competition Two Entrant Guide 2017 INDOOR Competition Two Easily Installed and Configured LED Troffer Conversion (Retrofit) Kits with Luminaire Integrated Sensors and Controls Entrant Guide Next Generation Lighting Systems Page 1 of

More information

LIGHTING. The floodlight conforms to the DRB-approved standards for security lights in the cluster.

LIGHTING. The floodlight conforms to the DRB-approved standards for security lights in the cluster. objective/goal To select and locate security lighting (floodlights) so as to illuminate the subject property and minimize the impact of glare onto neighboring properties. Review Process if your project

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CS 15-0l SCOPE: Street Lighting improvements shall be constructed in conformance with Section 86, Signals, Lighting and Electrical Systems, of the CALTRANS

More information

ELECTRICAL SYSTEMS. TEST YOURSELF QUESTIONS: Answer Key. CHAPTER 1: Sustainability in Electrical Systems

ELECTRICAL SYSTEMS. TEST YOURSELF QUESTIONS: Answer Key. CHAPTER 1: Sustainability in Electrical Systems ELECTRICAL SYSTEMS TEST YOURSELF QUESTIONS: Answer Key CHAPTER 1: Sustainability in Electrical Systems 1. What are the benefits of sustainability in green building design? The benefits of sustainability

More information

Luminaire & Controls Selection Guide I N C E N T V E S. Duke Energy Indiana

Luminaire & Controls Selection Guide I N C E N T V E S. Duke Energy Indiana Luminaire & Controls Selection Guide i n d i a n a I N C E N T I V E S Duke Energy Indiana Energy Solutions Your Cooper Lighting is at the forefront in transforming the lighting industry and setting an

More information

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN To aid in communication between yourself, the inspectors, and the plans examiners, we have prepared this sample plan to assist in the preparations of your plan for window and door replacement. Follow the

More information

LIGHTING SUPPLY (SE MICHIGAN) SPECIAL BUY CLOSEOUT

LIGHTING SUPPLY (SE MICHIGAN) SPECIAL BUY CLOSEOUT SPS2GFSVI332UNVH3 Fluorescent Troffer 2X4 Closeout Electronic Fluorescent Recessed 2x4 Troffer - 120V-277V, Spec Grade, Uses (3) F32T8 Lamps Not Included, White Fixture 16 $36.00 2SPG432-FS12-UNV-1/4-EB10R

More information

Association of Energy Engineers. A Practical Guide to LED Product Selection & Applications

Association of Energy Engineers. A Practical Guide to LED Product Selection & Applications Association of Energy Engineers A Practical Guide to LED Product Selection & Applications Joe Stoner January 25, 2018 What we will cover Types of LED s LED Metrics Controls ASHRAE 90.1-2010 Types of LED

More information

8 Dec 10. Project Address: 1304 West Pipeline Road Hurst, TX 76053

8 Dec 10. Project Address: 1304 West Pipeline Road Hurst, TX 76053 Duane Meyers AIA Architect Texas badlands & beyond... 8 Dec 10 8 Dec 10 Five Guys Burgers & Fries @ Shops @ NE Mall Plan eview esponse City of Hurst Edward Fisher, Commercial Building Inspector 1505 Precinct

More information

Daylight Dimming Systems: Studies in Energy Savings and Efficiency

Daylight Dimming Systems: Studies in Energy Savings and Efficiency Daylight Dimming Systems: Studies in Energy Savings and Efficiency Lynn Schrum, Danny S. Parker, and David B. Floyd, Florida Solar Energy Center Three studies were conducted at Florida Solar Energy Center

More information

Michigan Energy Code Training and Implementation Program

Michigan Energy Code Training and Implementation Program Michigan Energy Code Training and Implementation Program 1.0 Hour Advanced Program Course Number 16202 Residential Energy Plan Review School of Planning, Design & Construction Michigan State University

More information

CLARIS. Think Outside The Tube. LED RETROFIT KITS Revolutionary By Design

CLARIS. Think Outside The Tube. LED RETROFIT KITS Revolutionary By Design Think Outside The Tube CLARIS Revolutionary By Design CLARIS LED Retrofit Kits are designed for quick and easy replacement of fluorescent tubes within existing troffers. LED Living Technology s Retrofit

More information

Efficient Lighting Design- PCC Summer Sustainability Institute

Efficient Lighting Design- PCC Summer Sustainability Institute Efficient Lighting Design- PCC Summer Sustainability Institute Efficient Lighting Design Importance of efficient lighting Lighting science Color quality Lighting design Light sources CFLs Fluorescent fixtures

More information

Suggested Environmental Considerations for Lighting Equipment

Suggested Environmental Considerations for Lighting Equipment Suggested Environmental Considerations for Lighting Equipment Below are suggested environmental considerations for lighting equipment for health care that can be used to inform purchasing decisions in

More information

INSIDE RESCheck / COMCheck

INSIDE RESCheck / COMCheck INSIDE RESCheck / COMCheck What You Need to Know About UA NEBOEA October 2014 Don Vigneau, AIA Emeritus - Presenter IECC Compliance - Four Options Prescriptive R-Value and U-Factor R-values Table R402.1.1

More information

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications. For purchases made on or after January 1, 2016

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications. For purchases made on or after January 1, 2016 EXHIBIT 1 Washington Home Energy Savings Program Measures, s, and For purchases made on or after January 1, 2016 Per unit incentives for specific Energy Efficiency Measures (EEMs) are listed in the program

More information

Bi-Level Office Lighting with Occupancy Sensors

Bi-Level Office Lighting with Occupancy Sensors FINAL REPORT E3T Emerging Technology Assessment Bi-Level Office Lighting with Occupancy Sensors January 2011 Prepared for: This publication contains material written and produced for public distribution.

More information

PECO Smart Ideas for Your Business

PECO Smart Ideas for Your Business Follow This Easy Process: Step 1: Verify your Eligibility Applicant must verify that they are a business customer of PECO (commercial, industrial, governmental, institutional, and non-profit). Multifamily

More information

High Piled Combustible Storage Guideline

High Piled Combustible Storage Guideline Moreno Valley High Piled Combustible Storage Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 5, 2017 Rev: 7-28-16 City of Moreno Valley Fire Department Page 1 of 19 High Piled Storage

More information

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY H-4. Policy Subject: Number Page. CONSERVATION OF ENERGY H-4 1 of 7

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY H-4. Policy Subject: Number Page. CONSERVATION OF ENERGY H-4 1 of 7 CONSERVATION OF ENERGY H-4 1 of 7 : It is the policy of the Board of Supervisors that all County departments are responsible for conserving energy. The following departmental responsibilities are instituted

More information

2018 Manufactured Homes and Factory Built Housing

2018 Manufactured Homes and Factory Built Housing 2018 Manufactured Homes and Factory Built Housing Routt County Regional Building Department (RCRBD) is a Participating Jurisdiction in the Mobile Home Inspection Program (MHIP) approved by the Colorado

More information

T5 Tube UL, cul Pending DLC Pending (T5 Tube is compatible for the traditional ballast tube)

T5 Tube UL, cul Pending DLC Pending (T5 Tube is compatible for the traditional ballast tube) T5 Tube Light Ideal for decorative and ambient lighting in retail outlets, hotels, warehouses, government buildings, and multi-unit residences T5 Tube UL, cul Pending Light DLC Pending (T5 Tube is compatible

More information

Michigan Energy and Cost Savings

Michigan Energy and Cost Savings BUILDING TECHNOLOGIES PROGRAM Michigan Energy and Cost Savings for New Single and Multifamily Homes: 2012 IECC as Compared to the Michigan Uniform Energy Code 1 2012 IECC AS COMPARED TO THE MICHIGAN UNIFORM

More information

ENERGY INVESTIGATION. Energy Investigation Organization

ENERGY INVESTIGATION. Energy Investigation Organization Energy Investigation Organization A. Building Information, Energy Costs, and Energy Sources This section includes general questions about the school building, as well as questions about energy costs and

More information

Case Study Network Based Lighting Management Systems for Intelligent and Smart Buildings. Client NetApp India Pvt Limited Bangalore

Case Study Network Based Lighting Management Systems for Intelligent and Smart Buildings. Client NetApp India Pvt Limited Bangalore Case Study Network Based Lighting Management Systems for Intelligent and Smart Buildings Client NetApp India Pvt Limited Bangalore NetApp, Inc. (NetApp), incorporated in April 1992, is a provider of storage

More information

A. This Section includes lighting design criteria, interior and exterior luminaires, lamps and ballasts, as well as related installation guidelines.

A. This Section includes lighting design criteria, interior and exterior luminaires, lamps and ballasts, as well as related installation guidelines. SECTION 265000 LIGHTING This document is provided as a reference for the design professionals working for the University of Pennsylvania. This document should not be used directly as written project specifications.

More information

Questions & Answers. Amendments to Ontario Electrical Safety Code 23 rd Edition/2002

Questions & Answers. Amendments to Ontario Electrical Safety Code 23 rd Edition/2002 Questions & Answers Amendments to Ontario Electrical Safety Code 23 rd Edition/2002 When do the new rules become effective? Ontario amendments to the Ontario Electrical Safety Code 23 rd Edition/2002 comes

More information

COMPANY PROFILE. ledlivingtechnology.com AFFORDABLE LED SOLUTIONS HIGHEST QUALITY LIGHTING

COMPANY PROFILE. ledlivingtechnology.com AFFORDABLE LED SOLUTIONS HIGHEST QUALITY LIGHTING ledlivingtechnology.com COMPANY PROFILE LED Living Technology is the commercial lighting sister company of Metaphase Technologies Inc., the industry leader in manufacturing cutting-edge LED solutions for

More information

Compliance to the IgCC. September 29, 2011

Compliance to the IgCC. September 29, 2011 Bringing Outcome-Based Compliance to the IgCC September 29, 2011 Outcome-Based Codes: Any code requirement or code enforcement mechanism based on actual outcomes in buildings after they have been occupied.

More information

CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist

CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist CALGREEN NON-RESIDENTIAL BUILDING Plan Submittal Checklist VERSION 1.0 REVISED 12/19/16 New non-residential buildings shall be designed to include the green building mandatory measures specified in this

More information

Retrofit Lighting Opportunities September 12, 2012

Retrofit Lighting Opportunities September 12, 2012 Retrofit Lighting Opportunities September 12, 2012 Agenda Why Focus on Lighting? Lighting Technologies LED versus other Lighting Technologies LED Performance Requirements Case Studies Benefits & Savings

More information

Prescriptive Checklist for the 2015 Washington State Energy Code

Prescriptive Checklist for the 2015 Washington State Energy Code Prescriptive Checklist for the 2015 Washington State Energy Code Chapter 51-11R WAC STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2015 EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE, RESIDENTIAL

More information

Lutron High Bay Fixture Solutions

Lutron High Bay Fixture Solutions Lutron High Bay Fixture Solutions Lutron High Bay Fixture Solutions Why high bay fixtures? Lutron high bay fixtures enhance light quality and provide energy-efficient alternatives to traditional HID fixtures.

More information

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DEEMED SAVINGS TECHNICAL ASSUMPTIONS Product: Prescriptive rebates will be offered for replacement lighting equipment. New Construction rebates will be offered for new facilities or spaces overhauled for a new purpose. Custom rebates are

More information

Article 10 - ADMINISTRATIVE SECTION

Article 10 - ADMINISTRATIVE SECTION Article 10 - ADMINISTRATIVE SECTION 10.1 TITLE These Administrative Regulations along with the requirements included in the 2005 Edition of the National Electrical Code (NFiPA-70-2005) as approved by the

More information

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

Commercial Remodel Permit

Commercial Remodel Permit Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each

More information

CALGREEN NON-RESIDENTIAL BUILDING Checklist

CALGREEN NON-RESIDENTIAL BUILDING Checklist CALGREEN NON-RESIDENTIAL BUILDING Checklist REVISED 11/18/14 New non-residential buildings shall be designed to include the green building mandatory measures specified in this checklist. This checklist

More information