Invisi II Dual Flush/Single Flush Inwall/Under Counter/Induct/Inceiling Cistern. CI/SfB (74.4) n6 Date October 2014

Size: px
Start display at page:

Download "Invisi II Dual Flush/Single Flush Inwall/Under Counter/Induct/Inceiling Cistern. CI/SfB (74.4) n6 Date October 2014"

Transcription

1 The more CI/SfB (74.4) n6 Date October 2014 Invisi II Dual Flush/Single Flush Inwall/Under Counter/Induct/Inceiling Cistern Supersedes all previous issues The more stars the more water efficient WATER RATING A joint government and industry program Licence No Water Consumption 1.8 litres per flush per stall When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to: stars the more water efficient WATER RATING A joint government and industry program Licence No litres per full flush litres per half flush 3.5 litres per average flush When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to:

2 Invisi II Invisi II 4.5/3 Dual Flush Inwall/Under Counter/ Induct/Inceiling Installation 1.8 Single Flush Urinal Inwall/Induct/Inceiling Installations Shown with D.403 Invisi II Wall Hung Pan Bracket and Invisi Dual Flush Plate and Buttons. A 4.5/3 litre dual flush plastic cistern suitable for inwall, under counter, induct and inceiling applications. The cistern features a number of contemporary button design options with concealed fixing that are pneumatically operated for ease of operation and installation. The push can be activated remotely up to 4 metres from the cistern, ideal for care and custom applications. The cistern incorporates Caroma Smartflush water saving technology. For installation flexibility the cistern, bracket and specially designed waste pipe have been developed to be installed in a standard 90mm metal or timber stud wall applications. The cistern is adjustable to 6/3 litre dual flush. Extended pneumatic hoses are additional and separately Code No Alternatively the extended hose is also with the Remote Access Mounting Box kit Code No Invisi II Dual Flush Installations: Inwall The cistern can be fitted within a minimum cavity of 90mm with service access within the room via the standard or large button panel. A range of access panel kits are available to suit dual flush, single flush and remote push button positions. Under Counter The cistern can be fitted under counter with a minimum cavity depth of 90mm for front mount button installations and 100mm from the finished wall face to the counter's internal front face, for top mount button installations, as illustrated in Invisi II page 4 (not suitable for urinals). Induct The cistern is suitable for behind the wall installations in a single service duct, as illustrated Invisi II page 6. Inceiling The cistern is suitable for mounting in the ceiling duct where access is provided for adjustment and servicing. This installation requires the fabrication of a flush pipe using 40mm DWV and Flush Pipe Extension components contained in the Remote Mounting Box Kit Code No , as illustrated Invisi II pages 7 and 9. Due to the high head height only nominated Caroma boxed rim pans should be used with this installation. Invisi II Buttons Buttons and access plate are not included with the cistern, see Invisi II page 3 for available options. Invisi II Inwall/Under Counter/Induct/Inceiling Cistern For wall faced pan applications, Code No For wall faced pan installations the cistern is simply mounted in position with the two brackets which are screwed to the studwork. Invisi II Under Counter For wall hung pan applications, Code No The D.403 Invisi II WH Bracket is for concrete floors or stud wall installations. The bracket system is suitable for installation only where non compressible wall materials are used. Invisi II Inwall/Induct/Inceiling Cistern For wall hung pan applications, Code No The D.402 Invisi II WH Bracket is for concrete floors or stud wall installations. The bracket system is suitable for installation only where non compressible wall materials are used. Invisi II Structural Brick Wall For structural brick walls the cistern is fixed inwall and the wall hung pan is fixed using the D.788 Sanifix Bolt Through the Wall Bracket. Invisi II Urinal Single Flush: The Invisi II 3 star, 1.8 litre single stall urinal cistern is with instructions for conversion to suit two stall and three stall, and 0.8 litre applications. A copper sparge adapter is included in place of a flush pipe. Working pressure is minimum 30kPa to maximum 1000 kpa flow pressure. Colours: White, chrome and satin chrome button options available see Invisi II page 3. Dimensions: All dimensions are in millimetres and are subject to normal manufacturing tolerances. Caroma pursues a policy of continuing improvement in design and performance of its products. The right is therefore reserved to vary specifications without notice Water inlet connection To centre line of Note: Cistern height can be increased to 3m with additional flush pipe extension kit (adjustable) 205 max. flush pipe support Studs 400mm 420mm

3 Invisi II Page 3 Invisi II Buttons and Plates (suitable for cistern access) Invisi II Round Dual Flush Plate and Buttons Code No W Code No C Code No S Invisi II Rectangle Dual Flush Plate and Buttons Code No C Code No S Invisi II Round Care Dual Flush Plate and Raised Buttons Code No C Code No S Invisi II Rectangle Single Flush Plate and Button Code No C Code No S Invisi II Blank Access Plate Code No C Code No S Invisi II Custom Buttons (cistern requires alternative access) Invisi II Round Dual Flush Custom Buttons Code No C Code No S Invisi II Rectangle Dual Flush Custom Buttons Code No C Code No S Invisi II Round Single Flush Custom Button Code No C Code No S Invisi II Rectangle Single Flush Custom Button Code No C Code No S Invisi II Access Panel Options for Inwall Applications (Buttons separately) Large Access Panel Dual Flush Top Code No Note: Large access panels are recommended for double brick wall installations. Large Access Panel Single Flush Bottom Code No mm min. mm max. wall lining thickness 5mm min. mm max. wall thickness 5mm min. mm max. wall thickness Invisi II Remote Mounting Box Kit includes 2 x 4m pneumatic hose with flush pipe extension components For use with induct or remote mounted button installations. Code No m pneumatic hose Code No (2 hoses required for remote dual flush installations) Remote Button Plate Installation Standard button plate Installation Custom Button Installation

4 Invisi II Page 4 Under Counter Wall Faced Dual Flush Installation isolating valve, allows for side and back water connections A B C Cube Geo Leda to top of flush pipe support noggin A B min. C (+65 for Odourvac option suitable for front push only) 90mm min. front button installation 100mm min. top button installation Front mount Finished wall Top mount flush pipe support Bench thickness mm max. for top push Pan foot level Leda Wall Faced pan illustrated Note: access to cistern internals can be achieved through either front or top mount button plate option. Under Counter Wall Hung Dual Flush Installation A isolating valve, allows for side and back water connections Metro 408 Cube 408 Walvit min. 850 min. 915 min. for Odourvac option suitable for front push only A 90mm min. front button installation 100mm min. top button installation Front mount Finished wall Top mount Bench thickness mm max. for top push Finished floor Metro Wall Hung pan illustrated Note: access to cistern internals can be achieved through either front or top mount button plate option. The bracket system is suitable for installation only where non compressible wall materials are used.

5 Invisi II Page 5 Inwall Wall Faced Dual Flush Installation 90 min Frame isolating valve min. to underside of noggin and 6 min. max. wall thickness 582 Supplied (adjustable from ) min Frame isolating valve min. to underside of noggin and 6 min. max. wall thickness to top of flush pipe support noggin 965 Supplied (adjustable from ) Pan foot level flush pipe support Leda Wall Faced pan illustrated Uniconnector Note: access to cistern internals can be achieved through button plate. Recommended 90 setout ( range) Inwall Wall Hung Dual Flush Installation Spacer if required (Not ) 947 Stud fixing bolt kit ( Not ) Wall hung bracket suitable for structural slab or stud wall installation Cube Wall Hung pan illustrated Stud wall installation (For non-structural floor) The bracket system is suitable for installation only where non compressible wall materials are used. 408 ref Finished floor 40 For 100mm UPVC DWV connection use Caroma Invisi II wall hung waste connector 170 max. from finished wall with Invisi II WH pan connector Note: access to cistern internals can be achieved through button plate. 213

6 Invisi II Page 6 Induct Wall Faced with Remote Mounting Box Kit isolating valve 135 max. with flush pipe 5 min. max. wall lining thickness Remote mounted plate and Service duct (Cistern to be installed backwards for service duct access) 582 Supplied (adjustable from ) 25 to top of flush pipe support noggin Supplied (adjustable from ) 395 Pan foot level Use flush pipe extension kit for higher installation flush pipe support Leda Wall Faced pan illustrated Uniconnector Recommended 90 setout ( range) Induct Wall Hung with Remote Mounting Box Kit 135 max. with flush pipe isolating valve 5 min. max. wall lining thickness Remote mounted plate and Service duct (Cistern to be installed backwards for service duct access) Structural Wall Installation (Option) D788 Sanifix Bolt through wall bracket Code No ref Finished floor The bracket system is suitable for installation only where non compressible wall materials are used. Wall hung bracket suitable for structural slab or stud wall installation (Use D788 for structural wall installation) Cube Wall Hung pan illustrated For 100mm UPVC DWV connection use Caroma Invisi II wall hung waste connector 170 max. from finished wall with Invisi II WH pan connector The waste pipe must be accurately centralised to achieve a minimum wall cavity dimension of 90mm.

7 Invisi II Page 7 Inceiling Wall Faced with Remote Mounting Box Kit frame Invisi II Flush Pipe Extension 70mm Cavity (components with remote mounting box kit) Kee Seal Cistern Adaptor Breather Tube Cut to length and solvent weld (not ) 40mm 90 PVC DWV elbow (not ) Cut to length and solvent weld (not ) Invisi II Flush Pipe Extension 90mm Cavity (components with remote mounting box kit) Cistern Adaptor Kee Seal Breather Tube Cut to length and solvent weld (not ) Flush pipe Adaptor Flush Pipe (with cistern) isolating valve 90 Invisi II cistern Ceiling void Ceiling access 40mm DWV fabricated flush pipe Where the ceiling space is restricted the Invisi II can be dropped into the wall cavity. 4 metres long (max.) pneumatic tube (Included with remote mounting box kit) Note: Minimum wall cavity 70mm if cistern is inceiling. 90mm if cistern is in wall cavity. 150mm if uniconnector is in wall cavity. 4.5 min. max. wall cladding thickness 3m max. Remote mounted plate and 395 Flush pipe extension kit 25 to top of flush pipe support noggin Recommended push button position Pan foot level 25 flush pipe support 185 Leda Wall Faced pan illustrated Uniconnector Recommended 90 setout ( range) For 100mm UPVC DWV connection use Caroma Uniconnector PVC adaptor Vinidex Code No.785

8 Invisi II Page 8 4.5/3 LITRE DUAL FLUSH - Toilet Suites For 4.5/3 litre the bucket is preset. Connect pneumatic hoses to both the half flush and full flush positions. 4.5L 6/3 LITRE DUAL FLUSH - Toilet Suites For 6/3 litre flush remove outlet valve from cistern and bucket (see below), refit outlet valve in cistern. Connect the pneumatic hoses to both the half flush and full flush positions. Cut the 4 tabs to remove bucket 1.8 LITRE SINGLE FLUSH - Single Stall Urinal For 1.8 litre flush the bucket is preset. Connect the pneumatic hose to the full flush position. 0.8 LITRE - Single Stall Urinal For the 0.8 litre flush adjust the bucket to the 0.8L mark. Adjust water level to appropriate mark on cistern tank. Connect the pneumatic hose to the full flush position. 3.8 LITRE - 2 Stall Urinal For 3.8 litre flush, adjust the bucket to the 3.8L mark, and reset the water level to the corresponding mark on the cistern. Connect the pneumatic hose to either flushing position. 1.8L 5.8L LITRE SINGLE FLUSH - 3 Stall Urinal Conversion For 5.8 litre flush remove outlet valve from cistern and bucket (see below), refit outlet valve in cistern. Connect the pneumatic hose to either flushing position. Cut the 4 tabs to remove bucket

9 Invisi II Page 9 Flush pipe Extension Components (included in Remote Mounting Box Kit) Invisi II Flush Pipe Extension 90mm Cavity (components with remote mounting box kit) Breather Tube Cistern Adaptor Cut to length and solvent weld to adaptors (Not ) Flush pipe Adaptor Breather Tube Outlet Valve Flush Pipe ( with cistern) Kee Seal Invisi II Flush Pipe Extension 70mm Cavity (components with remote mounting box kit) Breather Tube Cistern Adaptor Cut to length and solvent weld (Not ) Cistern Base Kee Seal 40mm 90 PVC DWV elbow (Not ) - cut to length and solvent weld (Not )

10 Invisi II Page 10 Inwall/Induct Urinal Invisi II Installation Inwall Urinal Suite Induct Urinal Suite Frame isolating valve 6 min. max. wall thickness Finished wall 90mm min. cavity. 70mm min. for inceiling installation 5 min. max. wall lining thickness Service duct (Cistern to be installed backwards for service duct access) Blank Access plate 500 min. 335 to access panel Remote single flush push button Invisi II Cistern Ø20 sparge pipe 18 Reducer to Ø40 copper pipe Ø40 Flush pipe 65 Vitreous China Grate * 597 D.170 Concealed Fixing Bracket centre * mm recommended standard height. 400mm recommended disabled height (no pedestal). Finished floor standard 129 disabled

Invisi II. 242 For further information visit or call The more stars the more water efficient WATER RATING

Invisi II. 242 For further information visit  or call The more stars the more water efficient WATER RATING A joint government and industry program Licence No. 0001 When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to: Invisi II 4.5/3 litre Inwall/Under Counter/

More information

WALL HUNG WALL FACED CARE

WALL HUNG WALL FACED CARE WALL HUNG WALL FACED CARE invisible by choice CAROMA INVISI SERIES II TOILET SUITES ADD A WHOLE NEW DIMENSION TO BATHROOM DESIGN. WITH THE PLUMBING AND THE CISTERN OF THE TOILET SUITE SMARTLY HIDDEN BEHIND

More information

Points Available Points Claimed CIR Submitted N 1 0 N 1 1 N

Points Available Points Claimed CIR Submitted N 1 0 N 1 1 N Green Star Office Interiors v1.1 Water Wat-1 Potable Water Efficiency Points Available Points Claimed CIR Submitted 12 12 N 1 0 N 1 1 N Credit Criteria Up to twelve points are awarded where it is demonstrated

More information

TOILET SUITES SPACE SAVING SIMPLICITY

TOILET SUITES SPACE SAVING SIMPLICITY TOILET SUITES SPACE SAVING SIMPLICITY The new Fowler Icon Series II is toilet technology at its very best. Designed to perform, it s also designed to impress with sleek lines, smooth curves and smart styling.

More information

pricing and technical information caroma marc newson bathroom collection

pricing and technical information caroma marc newson bathroom collection pricing and technical information caroma marc newson bathroom collection collection one freestanding bath CMN8W, freestanding bath filler CMN92010C, shower mixer CMN92003C, rail shower with overhead CMN92008C3A,

More information

Our slimmest cistern. Sigma 75 concealed toilet cistern for back to wall pans

Our slimmest cistern. Sigma 75 concealed toilet cistern for back to wall pans Our slimmest cistern Sigma 75 concealed toilet cistern for back to wall pans Geberit concealed cisterns. Easy to install, tough and low maintenance. 75 mm Geberit has the most extensive product range of

More information

PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design.

PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design. PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design. Powerful Clean The PARISI innovative rimless toilets are the first in Australia to ensure optimum hygiene

More information

optional parts for geberit Duofix carrier

optional parts for geberit Duofix carrier geberit Duofix carrier.335.00.5 Installation accessories for concealed tank and carrier for wall-hung toilet. Accessories shall be for alternate frame installation and connection sets between carrier and

More information

Urbane Collection. caroma.co.nz

Urbane Collection. caroma.co.nz Urbane Collection caroma.co.nz caroma 02 03 urbane collection Urbane Collection Caroma Urbane Collection is a combination of functionality and design unity, ideal for a range of tastes. Consisting of toilet

More information

INTELLIGENT BATHROOM SOLUTIONS. specify.caroma.com.au

INTELLIGENT BATHROOM SOLUTIONS. specify.caroma.com.au INTELLIGENT BATHROOM SOLUTIONS We ve been an iconic Australian brand for over 75 years. From developing the first two-button Dualflush ceramic toilet in the world, to creating the award-winning ultra-low

More information

What s new in toilets? Taller cisterns!

What s new in toilets? Taller cisterns! product update Feb 2014 What s new in toilets? Taller s!.com.au maxim II STO-17 position 745mm replaces maxim STO-10W-S lagoa II STO-16 position 745mm replaces lagoa STO-10W limni II STO-15 position 745mm

More information

FORMA COLLECTION.

FORMA COLLECTION. FORMA COLLECTION. www. 2 Forma Collection Forma Collection 3 FORMA COLLECTION The Australian designed Forma basins and toilet suites distinctly encapsulates contemporary style with its communion of curvature

More information

BATHROOM RANGE TOILETS BASINS SPAS BATHS TOILET SUITES

BATHROOM RANGE TOILETS BASINS SPAS BATHS TOILET SUITES BATHROOM RANGE 1 TOILETS SPAS BATHS inspiring choices for your bathroom CONTENTS 3 contents It s the stand-out fixtures that determine the style of a bathroom; the basin, the vanity, the toilet suite,

More information

Concealed Flushing and Installation Systems. PERFORMANCE AND INNOVATION

Concealed Flushing and Installation Systems. PERFORMANCE AND INNOVATION Concealed ing and Installation Systems. PERFORMANCE AND INNOVATION 2 Thinking about saving water? Think GROHE. 3 Water, our most vital resource. Few people realize how much water they flush down their

More information

Geberit Duofix. Need a frame for every application? There s a Geberit for it.

Geberit Duofix. Need a frame for every application? There s a Geberit for it. Geberit Duofix Need a frame for every application? There s a Geberit for it. We ve got it covered The smart way to install sleek modern looking wall-hung toilets is with Geberit Duofix frame systems. Neatly

More information

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC TABLE OF CONTENTS Pictorial Index Product Recommendations Water Closet Carriers Matching Water Closet & Carrier Closet Carrier Selection & Battery Set-Up Stud & Nipple Adjustment to Finished Wall Anchoring

More information

Technology. Enabling Design. Geberit Duofix Carrier

Technology. Enabling Design. Geberit Duofix Carrier Technology Enabling Design Geberit Duofix Carrier Geberit is Behind It All! With millions of installations throughout the world, the message is clear: the Geberit Duofix Carrier allows unique design without

More information

Liano Collection. caroma.com.au

Liano Collection. caroma.com.au Liano Collection caroma.com.au caroma Liano Collection The newest additions to the Caroma Liano Collection a range of toilet suites, matte black tapware and accessories showcasing the very latest in design

More information

Shower and Floor Gullies SECTION

Shower and Floor Gullies SECTION Shower and Floor Gullies SECTION Shower and Floor Gullies 9 General Information McAlpine has responded to market conditions and customer demand by producing an extensive range of Shower and Floor Gullies

More information

SYSTEMS IDEAL FOR YOUR PROJECT SANITARY SYSTEMS STRENGTH YOU CAN TRUST

SYSTEMS IDEAL FOR YOUR PROJECT SANITARY SYSTEMS STRENGTH YOU CAN TRUST SANITARY SYSTEMS SANITARY SYSTEMS HOTELS OFFICES SYSTEMS IDEAL FOR YOUR PROJECT COMPRESSION WASTE TRAPS WC CONNECTORS FLOOR DRAINAGE SANITARY SYSTEMS STRENGTH YOU CAN TRUST HOSPITALS & CARE HOMES SCHOOLS

More information

Technology in bathrooms

Technology in bathrooms Technology in bathrooms Water saving with Geberit toilet flush... The world-wide use of water is increasing rapidly. In regions dominated by low water supply and an ever increasing population, an acute

More information

Wall-hung? We re right behind you.

Wall-hung? We re right behind you. Geberit Duofix Wall-hung? We re right behind you. The easy way to install the modern bathroom look your customers want. How easy? Find out more about Duofix from the professionals who already fit the system.

More information

194 SUPPORT FRAMES & CISTERNS

194 SUPPORT FRAMES & CISTERNS 194 SUPPORT FRAMES & CISTERNS SUPPORT FRAMES & CISTERNS Modern bathroom design enhances a natural feeling of light and space that can convert the smallest of bathrooms into a luxurious retreat. WC wall

More information

SUPPORT FRAMES & CISTERNS

SUPPORT FRAMES & CISTERNS SUPPORT FRAMES & CISTERNS Modern bathroom design enhances a natural feeling of light and space that can convert the smallest of bathrooms into a luxurious retreat. WC wall frames and concealed cisterns

More information

Appendix 4. Bills of Quantities

Appendix 4. Bills of Quantities Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic

More information

BOQ for Plumbing, Sanitary Works

BOQ for Plumbing, Sanitary Works BOQ for Plumbing, Sanitary Works Page of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) SANITARY FIXTURES a Providing & Fixing star white colour vitreous china wall mounted wc with heavy duty

More information

AS LN. WMKA SAI Global / ISC

AS LN. WMKA SAI Global / ISC TROPICAL XL2015 Short-projection wall-face WC suite Universal water entry LH rear or LH or RH side AS 1172.1-1172.2 LN. WMKA 30025 SAI Global / ISC The TROPICAL suite is all vitreous china, providing an

More information

Liano Collection. caroma.co.nz

Liano Collection. caroma.co.nz Liano Collection caroma.co.nz caroma caroma.co.nz 03 Liano Collection The newest additions to the Caroma Liano Collection a range of toilet suites, matte black tapware and accessories showcasing the very

More information

PROPOSED PUBLIC TOILET FACILITIES PEGASUS TOWN, SITE PLAN. 38 colombo street, christchurch. ph fax

PROPOSED PUBLIC TOILET FACILITIES PEGASUS TOWN, SITE PLAN. 38 colombo street, christchurch. ph fax FOR TODD PROPERTY PEGSUS TOWN LTD SITE PLN 1 190 1,910 190 610 190 1,910 190 Exterior recessed soffit light x 6 ( Switched from daylight sensor ) Mag lock to door. Mag lock to door. 190 2,210 190 llproof

More information

Duravit Vero toilet with Geberit Monolith in White Glass. Geberit Product Catalog May 2013

Duravit Vero toilet with Geberit Monolith in White Glass. Geberit Product Catalog May 2013 Duravit Vero toilet with Geberit Monolith in White Glass Geberit Product Catalog May 2013 Table of Contents Geberit Installation Systems Product features, installation scenarios, system components Page

More information

1.04 SUBMITTALS PLUMBING FIXTURES

1.04 SUBMITTALS PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

CHANGE ROOM & SPORTING AMENITIES

CHANGE ROOM & SPORTING AMENITIES CHANGE ROOM & SPORTING AMENITIES OUTDOOR TEAM SPORTS AMENITIES FOR SPORTING CLUBS Architecturally designed change room, restroom, shower, kiosk and equipment storage facilities for team sports. Standard

More information

CI/SfB (22.3) Rn8. wall panelling and access systems

CI/SfB (22.3) Rn8. wall panelling and access systems CI/SfB (22.3) Rn8 clipclad wall panelling and access systems 02 Grant Westfield Clipclad 03 Clipclad Grant Westfield Ltd is a leading manufacturer of panel products for demanding interiors. Having combined

More information

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial DRAINS: BATH,, SHOWER &, S COMMERCIAL SHOWER DRAINS GENERAL PURPOSE DRAINS FIT-FLUSH CLEAN-OUTS BATH WASTES BATH WASTES KITS/PARTS/COMPONENTS BATH DRAIN BODIES/ASSEMBLIES BATH DRAIN KITS/PARTS/COMPONENTS

More information

The ultra-low profile shower deck that s both stylish and easy to fit

The ultra-low profile shower deck that s both stylish and easy to fit The ultra-low profile shower deck that s both stylish and easy to fit for wet rooms you can trust Designed with YOU in mind As a home-owner you will appreciate the new aqua4ma linear Shower Deck for its

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 40 00_PLUMBING FIXTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Water closets. 2. Urinals. 3. Lavatories. 4. Sinks. 5.

More information

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1 16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories

More information

BILL OF QUANTITY PART-III CIVIL WORKS ITEM NO. DESCRIPTION UNIT QTY RATE AMOUNT

BILL OF QUANTITY PART-III CIVIL WORKS ITEM NO. DESCRIPTION UNIT QTY RATE AMOUNT Page 1 BILL OF QUANTITY PART-III CIVIL WORKS ITEM NO. DESCRIPTION UNIT QTY RATE AMOUNT 1 Providing and fixing door Closer/Bottle type Each 10 2 Providing and fixing door Stopper Each 10 Providing and placing

More information

Viega Eco Plus WC corner element. Instructions for Use. Viega Eco Plus from 07/2007. en_int

Viega Eco Plus WC corner element. Instructions for Use. Viega Eco Plus from 07/2007. en_int Viega Eco Plus WC corner element Instructions for Use Viega Eco Plus Model Year built: 8141.2 from 07/2007 en_int Viega Eco Plus WC corner element 2 from 23 Table of contents Table of contents 1 About

More information

Get to know us. Understanding people and their requirements that is what motivates

Get to know us. Understanding people and their requirements that is what motivates Understanding people and their requirements that is what motivates In this spirit, and with our customers in mind, we develop products and services that offer more room for creativity and convenience in

More information

E N I G M A COLLECTION

E N I G M A COLLECTION E N I G M A COLLECTION dorf.com.au 2 DORF.COM.AU 3 ENIGMA MIXERS Enigma exudes a sense of wellbeing with its bold, geometric looks and sleek proportions. // 01 // 04 Engima Basin Mixer // 01 (Black) 6480.905A

More information

Waterplex. Creative Rainwater Solutions 0800 RAINSAC ( )

Waterplex. Creative Rainwater Solutions 0800 RAINSAC ( ) Waterplex Creative Rainwater Solutions www.ecosac.co.nz www.reosac.co.nz 0800 RAINSAC (724 672) Creative Rainwater Solutions for New Zealand Homes Waterplex Group New Zealand s premier rainwater bladder

More information

CIVIL/INTERIOR RENOVATION WORKS OF BASEMENT-2 AT ADMINISTRATIVE OFFICE, SHIMLA

CIVIL/INTERIOR RENOVATION WORKS OF BASEMENT-2 AT ADMINISTRATIVE OFFICE, SHIMLA CIVIL/INTERIOR RENOVATION WORKS OF BASEMENT-2 AT ADMINISTRATIVE OFFICE, SHIMLA FINANCIAL BID/PRICE BID/SHEDULE OF QUANTITIES Sl.No. Description of Item Quantity Rate (Rs) Unit Amount (Rs) 1 Providing and

More information

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems. PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,

More information

DETAILED ESTIMATE FOR S & P OF PROPOSED 2 No. LABORATORY AT S. N. BOSE NATIONAL CENTRE FOR BASIC SCIENCES AT SALTLAKE, KOLKATA.

DETAILED ESTIMATE FOR S & P OF PROPOSED 2 No. LABORATORY AT S. N. BOSE NATIONAL CENTRE FOR BASIC SCIENCES AT SALTLAKE, KOLKATA. DETAILED ESTIMATE FOR S & P OF PROPOSED 2 No. LABORATORY AT S. N. BOSE NATIONAL CENTRE FOR BASIC SCIENCES AT SALTLAKE, KOLKATA. 1 Supplying fitting and fixing G.I. pipes TATA make with all necessary accessories,

More information

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount Revised Schedule B as per corrigendum no. SASB/NIT/Works/818/2016/09 dated 28.01.2016. SCHEDULE B (FINANCIAL BID) B- a FABRICATION AND SUPPLY OF 200 EUROPEAN TYPE TOILETS (Rate to be quoted in Rupees both

More information

Wall-mounted systems. By SCHELL. For professional sanitary rooms.

Wall-mounted systems. By SCHELL. For professional sanitary rooms. Wall-mounted systems. By SCHELL. For professional sanitary rooms. Installation technology Wall-mounted systems. By SCHELL. Installation technology for modern sanitary rooms. SCHELL is a recognised manufacturer

More information

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

THE INSTALLING INSTRUCTION FOR CONCEALED TANK THE INSTLLING INSTRUCTION FOR CONCELED TNK Important remind: 80mm300kgf FFL ccessories List:. Please read through this Instructions carefully prior to installation, and our company shall not be responsible

More information

Concrete Soffit Direct Fix

Concrete Soffit Direct Fix Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration

More information

Typical detail: New roof with breathable underlay

Typical detail: New roof with breathable underlay New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop

More information

Clipclad - Wall Panelling And Access Systems

Clipclad - Wall Panelling And Access Systems Clipclad - Wall Panelling And Access Systems Clipclad Alongside our design team Wills + Watson Associates Westfield Washrooms have developed Clipclad as the ultimate solution to precision wall panelling.

More information

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A SPECIFICATIONS AND SCHEDULE OF QUANTITIES Name of work: Renovation of toilets in main building near molecular biology lab Sl Rate Amount Schedule A 1 Demolishing concrete in cement mortar including disposal

More information

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens. SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS

More information

1. Section "Residential Plumbing Fixtures" for residential sinks.

1. Section Residential Plumbing Fixtures for residential sinks. SECTION 224216.16 - COMMERCIAL SINKS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INSTALLATION MANUAL CO-AXIAL VERTICAL FLUE KIT FOR SEELEY INTERNATIONAL BRAEMAR ECO-SUPERSTAR SH18, SH25 & WF25 HEATERS

INSTALLATION MANUAL CO-AXIAL VERTICAL FLUE KIT FOR SEELEY INTERNATIONAL BRAEMAR ECO-SUPERSTAR SH18, SH25 & WF25 HEATERS INSTALLATION MANUAL CO-AXIAL VERTICAL FLUE KIT FOR SEELEY INTERNATIONAL BRAEMAR ECO-SUPERSTAR SH18, SH25 & WF25 HEATERS Employers and Employees Responsibility The installation and maintenance of gas space

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE TRUMPF MEDICAL SYSTEMS Inc. Charleston, SC PRE-INSTALLATION GUIDE FOR CEILING MOUNTED EQUIPMENT MANAGEMENT SYSTEMS, SURGICAL / EXAM LIGHTS, AND FLAT PANELS EMS and Light Pre-installation Guide File: 110720

More information

FIRE RATING MATERIAL FIXING NOTES

FIRE RATING MATERIAL FIXING NOTES FIRE RATING MATERIAL FIXING NOTES FIRE RATING MATERIAL FIXING NOTES... 1 External Wall Systems... 2 Non load bearing steel stud walls... 3 LOAD-BEARING STEEL STUD WALLS... 3 NON LOAD-BEARING TIMBER STUD

More information

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions Thermatile Ten-Twelve Radiant Panels Installation instructions 2 IOM 53, Issue 6 - Thermatile TEN-TWELVE Contents Page 1 General 3 1.1 Description 3 1.2 Receipt and Preparation 3 1.3 Storage and Handling

More information

Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Product Data Installation Product Specifications Geberit Model No..08.xx. Features Water consumption: Dual flush

More information

Uniclass L721:N341. CI/SfB (74) X (L61) Tougher than stainless, styled like ceramic. UK Manufactured Heavy Duty Sanitaryware

Uniclass L721:N341. CI/SfB (74) X (L61) Tougher than stainless, styled like ceramic. UK Manufactured Heavy Duty Sanitaryware Uniclass L721:N341 Tougher than stainless, styled like ceramic. CI/SfB (74) X (L61) UK Manufactured Heavy Duty Sanitaryware Dudley Resan Unique sanitaryware and accessories that are tougher than stainless

More information

K FAIRFAX BATH & SHOWER TRIM SET ALSO K-T12007, K-12014, K-T Codes/Standards Applicable Specified model meets or exceeds the following:

K FAIRFAX BATH & SHOWER TRIM SET ALSO K-T12007, K-12014, K-T Codes/Standards Applicable Specified model meets or exceeds the following: Features Metal construction Brass valve bodies Rite-Temp pressure-balancing diaphragm design High-temperature limit setting for added safety Pressure-balancing mechanism of one-piece diaphragm cartridge

More information

Urbane Showers, Mixers and Accessories. caroma.co.nz

Urbane Showers, Mixers and Accessories. caroma.co.nz Showers, Mixers and Accessories caroma.co.nz caroma 02 Introducing the Caroma Collection - a combination of functionality and design unity, ideal for a range of bathroom spaces. Now consisting of showers,

More information

Installation Instructions

Installation Instructions For Bar Mixers & Bath Shower Mixers Installation Instructions Installers please note these instructions are to be left with the user 2180388E June 2008 CONTENTS Page Introduction 1 Safety warnings 1 Main

More information

RESAN RANGE. The new Dudley Resan range of sanitaryware and accessories provides an extremely reliable damage resistant solution in every application.

RESAN RANGE. The new Dudley Resan range of sanitaryware and accessories provides an extremely reliable damage resistant solution in every application. FOR DETILS OF OUR FULL PRODUCT RNGE, PLESE VISIT WWW.DUDLEYBTHROOMPRODUCTS.CO.UK 53 RESN RNGE The new Dudley Resan range of sanitaryware and accessories provides an extremely reliable damage resistant

More information

CYPRUS STONEX SHOWER FLOORS

CYPRUS STONEX SHOWER FLOORS page 1 of 14 Arena lanco Cemento Pizarra SPECIFICATIONS Recommended use Material Colour Availability Outlet Position Waste Type ase Height Size Availability & Weight Features Domestic, Hotel and Commercial

More information

FOREST PLACE 59 UNITS ERF 5586 PARKLANDS

FOREST PLACE 59 UNITS ERF 5586 PARKLANDS ANNEXURE "C" MATERIAL AND FINISHES SPECIFICATION FOREST PLACE 59 UNITS ERF 5586 PARKLANDS 1. FOUNDATIONS AND STRUCTURE Foundation walls are to be built in strict accordance with the municipal building

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

30mm Height Linear Drain Shower Trays

30mm Height Linear Drain Shower Trays Installation Instructions 30mm Height Linear Drain Shower Trays 9. Parts Supplied Description Qty Shower Tray Parts Supplied (Fitting Kit) Description Qty Description Qty Shower Drain Base Fix-KST Adhesive

More information

Basic Measuring and Calculations. Formulas, Workings Hints and Tips

Basic Measuring and Calculations. Formulas, Workings Hints and Tips Basic Measuring and Calculations Formulas, Workings Hints and Tips Start by writing down the formula When working out mathematics Ensure you show all working out (Marks will be awarded for working out)

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, are a part of this Section. 1.02 SUMMARY A.

More information

HZ501 & HZ502. White and Chrome Bottle trap Installation Instructions

HZ501 & HZ502. White and Chrome Bottle trap Installation Instructions TABLE OF CONTENTS Product Overview.. 2 How to Order.. 2 Product Specifications.. 2 Tools Required.. 2 Safety Instructions 3 Visual Check.. 3 Hygihose Installation. 3 Hygitrap Installation.. 5 Duct Connection

More information

Fixed & Tilt-Over Cabinet Base TC & TCTO Range

Fixed & Tilt-Over Cabinet Base TC & TCTO Range TC & TCTO Range Technical Specification All dimensions in mm unless otherwise stated Standards Applicable - Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997 - General Steelwork: BS1449:1991,

More information

Clipclad Wall Panelling And Access Systems

Clipclad Wall Panelling And Access Systems Clipclad Wall Panelling And Access Systems WASHROOM SOLUTIONS TECHNICAL DATASHEET Clipclad Westfield Washrooms developed Clipclad as the ultimate solution to precision wall panelling. Clipclad allows the

More information

PLUMBING FIXTURES

PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

(52.9) Rev 1.0 November 2009 John Newton & Co. Ltd. NEWTON SYSTEM 500 TITAN-PRO WHITE - PUMPING SYSTEM FOR NEWTON SYSTEM 500 INSTALLATION MANUAL

(52.9) Rev 1.0 November 2009 John Newton & Co. Ltd. NEWTON SYSTEM 500 TITAN-PRO WHITE - PUMPING SYSTEM FOR NEWTON SYSTEM 500 INSTALLATION MANUAL Cl/SfB 993 (52.9) X Rev 1.0 November 2009 John Newton & Co. Ltd. NEWTON SYSTEM 500 TITAN-PRO WHITE - PUMPING SYSTEM FOR NEWTON SYSTEM 500 INSTALLATION MANUAL INTRODUCTION CONTENTS The Titan-Pro White Pumping

More information

MONOLITH. Basin System. installation + maintenance

MONOLITH. Basin System. installation + maintenance MONOLITH Basin System installation + maintenance contents 3 Monolith 5 4 Components List 5 Technical Data 6 Before you Install 10 Installation 14 ADA Compliance 15 Operation 15 Maintenance 16 Cleaning

More information

VICONNECT. The clever connection

VICONNECT. The clever connection VICONNECT The clever connection Manufacturer: Product category: Type: Model: Registration number: Water Efficiency Criteria Flush volume 6,0 l Flush volume 5,0 /,0 l With flush stop function Dual flushing

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

In-Wall Tank and Bowl Carrier System With Dual Flush Technology Geberit Model No Flush Volume: 1.6 / 0.8 GPF / 3.

In-Wall Tank and Bowl Carrier System With Dual Flush Technology Geberit Model No Flush Volume: 1.6 / 0.8 GPF / 3. D400-00 07-00 965.94.00.0 (00) In-Wall Tank and owl Carrier System With Dual Flush Technology Geberit Model No..78.00. Flush Volume:.6 / 0.8 GPF - 6.0 /.0 LPF Product Data Product Specifications - For

More information

S pecifications and I nclusions

S pecifications and I nclusions S pecifications and I nclusions STRUCTURAL / EXTERNAL / GARAGE FLOORING BUTLERS PANTRY (House Specific) A choice of feature front doors Brickwork over windows (house/facade specific) Aluminum stacker or

More information

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. SECTION 13 PIPE, TUBE AND PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. 1.02 QUALITY ASSURANCE

More information

W i s d o m S m a r t C o l l e c t i o n. Aristotle series

W i s d o m S m a r t C o l l e c t i o n. Aristotle series W i s d o m S m a r t C o l l e c t i o n Aristotle series 8490mm Aristotle 16 Area Calculations ARIstotle 16 Itemised Floor Areas Ground Floor Garage Porch Outdoor Leisure Area 118.22 sqm 20.04 sqm 1.53

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction Pipeline Accessories PSI Wall Sleeves General Information Selection Guide Technical Data Installation Instruction 1 PSI Wall Sleeves made of steel General Information An economic method to seal hydrostatically

More information

Urbane Showers, Mixers and Accessories. caroma.com.au

Urbane Showers, Mixers and Accessories. caroma.com.au Showers, Mixers and Accessories caroma.com.au caroma 02 urbane collection Shower Range Introducing the Caroma Collection - a combination of functionality and design unity, ideal for a range of bathroom

More information

Section 12 Hydraulics.

Section 12 Hydraulics. Design Guidelines Section 12 Hydraulics. www.canterbury.ac.nz/learningresources Standards in the Design Guidelines Suite Design Standard Guidelines Index: 01 General 02 Architecture 03 Audio Visual 04

More information

PND Training Hall Conex Building, Kabul ABSTRACT OF COST

PND Training Hall Conex Building, Kabul ABSTRACT OF COST PND Training Hall Conex Building, Kabul ABSTRACT OF COST A Civil Works All work items shall be carried as per drawing, specification and instruction of the Engineer. 1 Sub-structure Works Earthwork in

More information

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE Model P33-NG10 P33-LP10 P33E-NG10 P33E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) 5 W.C. (1.25 kpa) 11 W.C. (2.74 kpa) Manifold

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work

More information

BLOCKWORK All reinforced concrete blockwork is be constructed in accordance with AS 3700 and a relevant engineers report. A damp proof course ( DPC ) is to be provided 150mm above ground. BRICKWORK All

More information

Element D Services Plumbing

Element D Services Plumbing Fixtures PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses plumbing fixtures, trim and associated accessories. Refer to MD Anderson Cancer Center Master Construction Specification Sections for additional

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved SECTION 22 14 00 - PLUMBING DRAINAGE AND CONTAINMENT Copyright 1998-2017 Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. SLOT shaped, non-grated,

More information

COMPRESSED AIR FITTINGS

COMPRESSED AIR FITTINGS COMPRESSED AIR FITTINGS A push-fit system of fittings and pipe which means a compressed air system can be installed quickly and easily with much reduced production down time. It is also easy to rearrange

More information

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 04 05 PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Over floor trunking 0 300 9 0 300 93 0 38 00 Conform to standard EN 50085-- For creating a link between trunking, column,

More information

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these

More information