Typical detail: New roof with breathable underlay
|
|
- Oswald Burke
- 6 years ago
- Views:
Transcription
1 New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop at head of wall 6. Breathable roof tile underlay Habitable space: plasterboard and skim/vcl with taped joints VCL to be carefully cut and sealed around struts, ceiling joists and penetrations); batten/counter batten rafters as necessary to achieve insulation depth, confirm rafter strength sufficient to receive counter battening and boarding if required. Loft space only, non habitable: insulated between and over rafters to achieve target U-value. WALLTITE may remain exposed. 5
2 Existing roof with breathable underlay. WALLTITE CL00 insulation to achieve target U-value. Plasterboard and skim (optional). Unventilated air space. WALLTITE returned to insulated cavity stop at head of wall 5. Non-combustible cavity stop, well bedded and sealed Habitable space: plasterboard and skim/vcl with taped joints (VCL to be carefully cut and sealed around struts, ceiling joists and penetrations); batten/counter batten rafters as necessary to achieve insulation depth, confirm rafter strength sufficient to receive counter battening and boarding if required. Loft space only, non habitable: insulated between and over rafters to achieve target U-value. WALLTITE may remain exposed in a non-habitable loft space. Repair all roof defects and thoroughly overhaul where necessary prior to spraying. 5
3 Room in a roof insulation. 00mm x 50mm rafter. Unventilated air space. Plasterboard and skim. Flooring 5. WALLTITE CL00 insulation to achieve target U-value 5 Habitable space: plasterboard and skim/vcl with taped joints VCL to be carefully cut and sealed around struts, ceiling joists and penetrations); batten/counter batten rafters as necessary to achieve insulation depth, confirm rafter strength sufficient to receive counter battening and boarding if required. Loft space only, non habitable: insulated between and over rafters to achieve target U-value. WALLTITE may remain exposed.
4 External industrial roof. ELASTOSPRAY insulation to achieve target U-value. Metal deck. Roof beams
5 New roof with board insulation. WALLTITE CL00 insulation between rafters to achieve target U-value. Over rafter PIR board insulation (minimum 50mm thick). Breathable roof tile underlay. Counter-batten 5. Unventilated air space 6. Plasterboard and skim 5 Habitable space: plasterboard and skim/vcl with taped joints VCL to be carefully cut and sealed around struts, ceiling joists and penetrations); batten/counter batten rafters as necessary to achieve insulation depth, confirm rafter strength sufficient to receive counter battening and boarding if required. Loft space only, non habitable: insulated between and over rafters to achieve target U-value. WALLTITE may remain exposed. 6
6 New timber frame wall Plasterboard and skim. Vapour control layer to be lapped over at floor level and returned to window reveal and jambs. Unventilated air space. Sheathing ply 5. Breather membrane 6. WALLTITE CL00 insulation to achieve target U-value 7. 50mm air gap 8. Noggin to support plasterboard 9. Sill plate 0.. Treated timber cill support fixed to timber frame, clad and protected in with insulation set above Allow for differential movement at ALL openings, i.e. at window cill and window heads, as recommended by the timber frame manufacturer/uktfa/trada: to accommodate differential movement and provide weather resistant and durable joint.
7 Existing solid wall. 5mm WALLTITE behind studwork. Treated timber studs set off by wall by brackets. WALLTITE CL00 insulation between and behind studwork to achieve target U-value. Unventilated air space 5..5mm vapour check wallboard and skim finish At corners of internal and external walls to rooms, set frame to external wall back from corner a minimum of 5mm and set batten to line with vapour check wall boarding to receive board end to internal wall. 5
8 Existing solid wall. WALLTITE CL00 insulation between and behind studwork to achieve target U-value. Galvanised metal frame independent of the wall. Unventilated air space..5mm vapour check wallboard and skim finish
9 New cavity wall. Insulated cavity closer to be well sealed at edges. WALLTITE CV00 insulation injected into cavity to achieve target U-value. Lightweight blockwork. Cavity tray 5. New masonry brick Habitable space: plasterboard and skim/vcl with taped joints (VCL to be carefully cut and sealed around struts, ceiling joists and penetrations); batten/counter batten rafters as necessary to achieve insulation depth, confirm rafter strength sufficient to receive counter battening and boarding if required. Loft space only, non habitable: insulated between and over rafters 7to achieve target U-value. WALLTITE may remain exposed. 5
10 External soffit insulation. WALLTITE CL00 insulation to achieve target U-value. Suspended ceiling `
11 Ground floor insulation (concrete slab) 5 60mm.. Separating layer 500 gauge DPM returned up wall at perimeter. WALLTITE returned to form wall perimeter insulation. Screed 5. DPM set below slab 6. Sand blinding 7. Well consolidated hardcore 8. Concrete slab 8 7 6
12 Drilling patterns for cavity widths between 0 mm and 50 mm 0.7m (three bricks) Drilling patterns for cavity widths between 50 mm and 00 mm 0.8m (two bricks) 0.8m (six bricks) 0.m (three bricks) 0.8m (two bricks) Top of insulation at roof level 0.0 (five bricks) 0.m (three bricks) Top of insulation at roof level Drilling pattern at roof level 0.6m (½ bricks) Drilling pattern at roof level Staggered drilling pattern Staggered drilling pattern 0.8m (two bricks) Door or window opening 0.m (four bricks) Distance greater above door or window to avoid lintel 0.m (four bricks) Party line 0.6m (½ bricks) Drilling pattern at a party wall 0.6m (½ bricks) Door or window opening 0.m (three bricks) 0.m (three bricks) Party line 0.6m (½ bricks) Drilling pattern at a party wall Door and window frame drilling pattern 0.m typical (one brick) Door and window frame drilling pattern
Garage Conversion - Between and Under Joist Applications
Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,
More informationTW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork
Insulation CI/SfB (21.9) Rn7 M2 First Issue May 2017 e with retaining clip TW50 STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY 25 mm / 50 mm residual cavity Kingspan Thermawall TW50 Outer
More informationSITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT
SETTING OUT Correct to boundaries Correct to building lines? Diagonals accurate? Levels correct? EXCAVATIONS Adjoining structures OK? Centres of foundations line with walls? Bottoms of trenches uniform,
More informationCI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings
Insulation CI/Sfb (2 ) Rn7 M2 Fourth Issue June 2011 Product Selector INSULATION FOR ROOFS, WALLS & FLOORS Visit our brand new website: www.kingspaninsulation.co.uk Low Energy Low Carbon Buildings Kingspan
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More informationThe Celotex Handy Guide
The Celotex Handy Guide celotex.co.uk When you choose Celotex, you re choosing a unique level of service, support, online tools and aftercare. In fact, some of that support is in your hands right now.
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More informationTECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9
MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account
More informationInsulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings
Insulation Second Issue November 2016 Quick Guide Building a better Kingdom together. Low Energy Low Carbon Buildings 2 Contents Page About Kingspan Insulation 4 Product Range 5 Building Regulations /
More informationNU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)
September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More informationConstruction details:
Extension Specifications, 23 Nightingale Avenue Floor area (internal): 27.6m 2 Gross floor area: 31.9m 2 Construction details: Walls Construction from inside: (Option A) wet plaster (airtightness layer
More informationHow to fill in your Timber Frame Order Form
How to fill in your Timber Frame Order Form 1 General Would you like us to check slab or design the building to Architects drawings? Check Slab: Is the Slab in place already, if so has your architect checked
More informationURSA MINERAL WOOL URSA Cavity Batts
s 073_Layout 1 02/10/2017 10:18 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail : ursauk@ursa.com
More informationThermal Laminate Board.
Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly
More informationREFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES
CI/SfB (47) Ln6 Uniclass Pr_25_57_10_68 January 2018 REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES................................ ........................................................ REFLECTIVE TECHNOLOGY
More information9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :
Aalto! / ENG + ARC Asuinrakennusten rakenneratkaisut Requirements : Sound insulation requirements : Thermal insulation requirements : 1 Wall structures : Concrete wall : Concrete outer cover (with cavities)
More informationPITCHED ROOF SOLUTIONS
PITCHED ROOF SOLUTIONS, airtightness and moisture management solutions for pitched roof rafter applications. isover.co.uk Pitched Roof Solutions Building extra living space within the attic is a great
More informationBuilding Regulations for the Conservation of Fuel & Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel & Power ENGLAND EXISTING BUILDINGS OTHER THAN DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents
More informationMulti-layer Insulation Blanket for use in Walls
To order Superquilt online for free delivery within the UK Mainland visit www.ecohome-insulation.com or call 0844 9919949 To order Superquilt online for delivery within Europe and pay online by Euro visit
More informationEcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.
Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System
More informationHOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD
HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES WITH PLASTERBOARD GTEC THERMAL BOARD 1 BUILDING INSULATION THE REGULATIONS Building regulations are in place to drive improvements in thermal efficiency,
More informationTimber Separating Walls 3.3.3
3.3.3 Timber Separating Walls CONSTRUCTION DETAILS 246 INTRODUCTION Timber double stud walls are commonly used as separating walls, providing fire safety and acoustic separation between dwellings. This
More informationInstallation instructions Thin, flexible multi-foil insulation
The original BBA certified multi-foil Installation instructions Thin, flexible multi-foil insulation Below rafter 0.18 solutions Below 100 rafter + 70 foiled 70 foiled 165.5 spacer batten min 10 38 batten
More informationIntroduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.
Introduction This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will satisfy
More informationSuspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System
More informationGypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.
GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent
More informationSection 11 FIRE STOPPING
Section 11 This section highlights the key points relating to Fire Stopping. It is imperative that sites teams understand the importance of fire stopping and check it is completed correctly. It is to be
More informationCI/SfB (23) Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Joist end Fitting Aluminium Foil Bubble Insulation General Purpose Insulation Dry Lining Insulation
More informationBuilding Design Data
Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the
More informationSOUTH ELEVATION OF CLASSROOMS. NORTH ELEVATION OF CLASSROOMS (section through hall) HaysomWardMiller Architects CLASS ELEVATIONS
SOUTH ELEVATION OF CLASSROOMS NORTH ELEVATION OF CLASSROOMS (section through hall) CLASS ELEVATIONS 7 Downing Place, Cambridge, CB2 3EL, UK T: 01223 578545 F: 01223 351955 E: info@haysomwardmiller.co.uk
More informationCeiling Attenuation Class Systems SYSTEMS 280
SYSTEMS 280 Ceiling Attenuation Class Ceiling Attenuation Class (CAC) ceiling systems display resistance to sound passing up and over a wall. The sound insulation rating given for the ceiling system indicates
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationXtratherm Thin-R Thermal Liner (XT/TL Grade)
CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate
More informationSTRUCTURAL TIMBER ASSOCIATION
Version 2.0 - August 2016 STRUCTURAL TIMBER ASSOCIATION Building solutions in timber Delivering building control through local authorities Technical support for the STA pocket guide kindly provided by
More informationReal Stone Cladding mm sandstone ashlar. Thin Sandstone Ashlar Catalogue
12 15 20 mm sandstone ashlar Thin Sandstone Ashlar Catalogue 12 15 20 mm ashlar 1 SANDSTONE ASHLAR 12 15 20 MM Ashlar sandstone is the most desired and expensive stone finish for any facade. It is now
More informationMATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19
SCANDIA-HUS FACT SHEET NO. 4 MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19 THIS FACT SHEET SHOULD BE READ IN CONJUNCTION WITH OUR SHELL ERECTION SCHEDULE FACT SHEET NO. 13 -
More informationGypLyner (walls) Metal framed wall lining system. GypLyner.
GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal
More informationLimiting thermal bridging and air leakage: Robust construction details for dwellings and similar buildings. robust details
DEFRA Department for Environment, Food & Rural Affairs DTLR TRANSPORT LOCAL GOVERNMENT REGIONS Limiting thermal bridging and air leakage: Robust construction details for dwellings and similar buildings.
More informationGarage Conversions. Technical Issues
Garage Conversions Introduction: if you need more space and you do not want to move house you may wish to consider converting your garage. Your home is probably your most valuable asset so it is important
More informationBENCHMARK Evolution Axis
Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL
More informationSOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals
SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY BRANZ Appraisals Technical Assessments of products for building and construction. Product 1.1 is a self-adhesive, synthetic underlay for use over rigid wall
More informationCo-extruded 3 Layer Films
Co-extruded 3 Layer Films INTRODUCING THE NEW GUNDLE SABS RANGE OF 3 LAYER CONSTRUCTION MEMBRANES Multi-layer co-extrusion has the following advantages: It has a cross-linking effect between the different
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationFeature Zone IECC 2009 IECC
Feature Zone 3 2006 IECC 2009 IECC Window U factor 0.65 0.50 Skylight U factor 0.65 0.65 Window SHGC 0.40 0.30 Ceiling R value 30 30 Wood frame R value 13 13 Mass wall R value 1 5 5/8 Floor R value 19
More informationDay Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red
Plant Areas External plant must meet the following noise suppression requirement as adopted by the Landlord: 1. Air handling units 45db measured at 3metres from source. 2. Heat rejection plant 45db measured
More informationGypLyner UNIVERSAL Metal framed wall lining system
Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system
More informationSOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014
SOLITEX EXTASANA WALL PROTECTION MEMBRANE Amended 06 May 2014 BRANZ Appraisals Technical Assessments of products for building and construction. Pro Clima Australia Pty Ltd PO Box 924 Gosford NSW 2250 Australia
More informationSITE MAIN ROUTES AGRICULTURE AGRICULTURE SCHOOLS MASTER PLAN
CULTIVATING COMFORT URBAN SITE MAIN ROUTES AGRICULTURE SCHOOLS AGRICULTURE MASTER PLAN GENTRIFICATION AGRICULTURE INTERVENTION NEW AXIS COMMERCIAL TRAIN STATION MASTER PLAN SITE PLAN MIXED USE PUBLIC
More information0331 Brick and block construction
0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To
More informationGypLyner UNIVERSAL Metal framed wall lining system
Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury
More informationBASF Polyurethane - Walltite Isolation Wärmedämmung
IRISH AGRÉMENT BOARD CERTIFICATE NO. 13/0377 BASF Polyurethanes UK Ltd Wimsey Way, Somercotes Alfreton, Derbyshire, DE55 4NL, UK Tel: +44 (0) 1773 601166 Fax: +44 (0) 1773 602089 Web site: www.walltite.basf.co.uk
More informationThe Passive Fire Protection Handbook
The Passive Fire Protection Handbook The UK s comprehensive guide to passive fire protection Chapter Ceilings, Floors and Roofs AUGUST 0 The Passive Fire Protection Handbook Contents Chapter : Introduction
More informationExternal Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185
Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR
More informationSpecialists in Acoustic Flooring and House to Flat Conversions
Sound Solution Consultants Ltd Po Box 755 Capel St Mary Ipswich Suffolk IP9 2WF Tel No: 0845 5212096 Fax No: 0845 5212097 Email: mpconsultservice@aol.com Specialists in Acoustic Flooring and House to Flat
More informationAIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.
AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW www.stromatech.com AIR BARRIER DESIGN PRINCIPLES Building Regulations Approved Document Parts L1A & L2A currently requires that new buildings have to achieve a
More informationThe World of Floor Technology
The World of Floor Technology THE POSI-JOIST TECHNICAL HANDBOOK FEATURING An Introduction to Posi-Joist Installation Guidance Posi-Joist Applications throughout your building Acoustic Performance & Separating
More informationGENERAL INSTALLATION GUIDELINES
GENERAL INSTALLATION GUIDELINES VIEW ACTIS HYBRID VIDEOS ON General information HYBRIS is an insulation material generally used for roof, wall, ceiling and suspended timber floor applications. HYBRIS is
More informationProduct Information Sheet
Product Information Sheet Product Name ISOVER Metac - high performance insulation Metac G3 Touch is a high performance low lambda mineral wool insulation roll with both excellent thermal and acoustic properties.
More informationFutureproof solutions. Your Guide to Building Energy Ratings (BER)
Futureproof solutions Your Guide to Building Energy Ratings (BER) Contents Building regulations uncovered 02 BER chart 04 Explanation of terms used 05 Summary chart 06 Solid ground floor 08 Partial fill
More informationThe extra strong, extra durable, sound resistant system that you can direct fix to
C0 Partitions The extra strong, extra durable, sound resistant system that you can direct fix to All our systems are covered by SpecSure when using genuine Gyproc and Isover products gyproc.ie Utilising
More informationDefinition of Wall. A continuous, vertical structure Thin relatively to its length and height
Walls & Partition Learning Objectives Briefly explain the functions & functional requirements of walls Differentiate and compare between load bearing and non-load bearing walls Briefly describe the characteristics,
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationJune Residential New Build Render and cladding walls
June 2010 Residential New Build 2.5.4 Render and cladding walls Residential new build 2.0 Residential New Build Render and Clad Contents Introduction find online page Solution optimiser and pathfinder
More informationStaggered stud acoustic partition system
C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework
More informationSECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.
SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered
More informationTRISO-SUPER 10 INSTALLATION GUIDELINES
2009 Edition ACTIS THIN MULTIFOIL INSULATION INSTALLATION GUIDELINES ROOFS ATTICS EUROPEAN TECHNICAL APPROVAL IN PROCESS Registration N 12.01/12 2 Contents Technical characteristics 2 Essential rules of
More informationPowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide
PowerDeck F PIR insulation for Warm Flat Roofs. Product Guide Introduction The Company. Driven by a culture of innovation, technical competence and flair, Recticel Insulation Products is dedicated to raising
More informationEXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,
More informationFloors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited
Floors Walls Roofs APPLICATION: Basements PRODUCTS: Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board Vencel Resil Limited Head Office: Infinity House, Anderson Way, Belvedere,
More informationACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings
ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory
More informationISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Typically RMS Class 1 Wood frame walls, floors, and roof deck Brick Veneer, wood/hardiplank siding, stucco cladding Wood frame roof with wood decking and typical
More information155 & 220 Beam Flooring Systems
155 & 220 Beam Flooring Systems Benefits Minimum site preparation - just remove topsoil and vegetation to provide a minimum 75mm void or 150mm for clay between underside of floor and ground surface. No
More informationCross Laminated Timber (CLT)
Cross Laminated Timber (CLT) Lesson Learning Objectives To provide an awareness of the use of cross laminated timber (CLT) in multistorey construction. To develop an awareness of how CLT panels are fixed
More informationXtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)
CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as
More informationFloors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited
Floors Walls Roofs APPLICATION: Internally Lined Pitched Roof PRODUCTS: Jablite Premium board Jablite board Vencel Resil Limited Head Office: Infinity House, Anderson Way, Belvedere, Kent DA17 6BG Tel:
More informationCivil Engineering Construction Chapter 5
Civil Engineering Construction Chapter 5 Introduction to Floor Dr Mohamad Syazli Fathi Department of Civil Engineering UTM RAZAK School of Engineering & Advanced Technology UTM International Campus August
More information84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.
84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes 90 System Components installation/ SYSTEM COMPONENTS INSTALLATION ADVICE LAPPING and JOINTING
More informationPurAcell Isolation Wärmedämmung
CI/SfB (29) IRISH AGRÉMENT BOARD CERTIFICATE NO. 16/0389 EKO-Vision Building Products Ltd. Syngefield Business Park Birr, Co. Offaly T: +353 579122827 W: www.ekovisionltd.com E: Info@ekovisionltd.com PurAcell
More informationLimiting Thermal Bridging and Air Infiltration Acceptable Construction Details
Limiting Thermal Bridging and Air Infiltration Acceptable Construction Details Government of Ireland 2008 July 2008 INTRODUCTION This guide to Acceptable Construction Details (ACDs) is intended to help
More informationAND ACCESSORIES FOR DRYWALL CONSTRUCTION
STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR
More informationDETAILS. Developed by
S Developed by LEGEND LEGENDE LEGENDA LÉGENDE ENGLISH DEUTSCH ESPAGNOL FRANCAIS Straw Ecococon panel XPS Extrude polystyrene Cork EPS Expanded polystyrene STEICOprotect / universal STEICOfloor, STEICOtherm
More informationFIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250
FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC
More informationMeasuring Walls in Accordance with ARM4 - An Introductory Demonstration
Dublin Institute of Technology ARROW@DIT Other Resources School of Surveying and Construction Management 2017-11-20 Measuring Walls in Accordance with ARM4 - An Introductory Demonstration Tony Cunningham
More informationSECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.
SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient
More informationSECTION NON-STRUCTURAL METAL FRAMING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationHalfen systems for the support and restraint of brickwork
Halfen Brickwork Support Systems Halfen systems for the support and restraint of brickwork Introduction Halfen is a leading supplier of channel fixing systems and building components, with manufacturing
More informationCHAPTER 7: Superstructure
CONTENTS 7.1 EXTERNAL MASONRY WALLS 7.2 STEEL FRAME 7.3 TIMBER FRAME 7.4 WINDOWS AND DOORS 7.5 CHIMNEYS 7.6 BALCONIES 7.7 CLADDING 7.8 ROOF STRUCTURE 7.9 ROOF COVERINGS - TRADITIONAL SLATE AND TILES 7.10
More informationSTEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN
STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME
More informationWALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START
CLICK TO START About Knauf Metal Knauf Metal is part of the Knauf Group, leaders in lightweight construction materials, and a major supplier and manufacturer of metal building systems to the Australian
More informationSpecification Guide INSULATION EXCELLENCE
Specification Guide INSULATION EXCELLENCE Floors CONTENTS RECTICEL RAISING THE STANDARDS 03 RECTICEL PIR THE ADVANTAGES 04 RECTICEL HIGH PERFORMANCE IN FLOORS 05 EUR THANE GP 06 TYPICAL INSTALLATION EUR
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationRESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST
This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general
More informationURSA MINERAL WOOL URSA Acoustic Roll
- 073_Layout 1 02/10/2017 10:19 Page 1 URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail
More informationV1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide
V1/0715/AI/TDO1 KORE Loft Insulated Flooring System Design Guide KORE Loft Insulated Flooring System Key Features Excellent thermal performance for the lifetime of the building Sheets tongue and grooved
More informationLOFT CONVERSIONS. and the BUILDING REGULATIONS. Simplified Guidance
A City and County of Swansea Dinas a Sir Abertawe Environment Department The Guildhall, Swansea SA1 4PE Tel No: (01792) 635636 Fax No: (01792) 648079 e-mail: www.swansea.gov.uk/bcon Minicom: (01792) 635609
More informationFire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.
( ) is a new and innovative system designed to provide high performance separating walls between units and apartments in low-rise residential and commercial projects. provides exceptional fire and acoustic
More informationDuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2
DuPont Tyvek Air Barrier Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3 General
More informationPARKSIDE QUARRIES Ltd
5mm min. vent space soffit lining optional 20x20 bead optional cavity vents formed to top course of veneer 2 5 Wall ties screw fixed over underlay to structural frame and positioned within 300mm or two
More informationBenefits of off site manufacture
Case Study Benefits of off site manufacture Jocelyn Park, Somerset Jocelyn Park is a housing development owned and managed by South Somerset Homes Housing Association. There are 64 homes on site designed
More information