Invisi II. 242 For further information visit or call The more stars the more water efficient WATER RATING

Size: px
Start display at page:

Download "Invisi II. 242 For further information visit or call The more stars the more water efficient WATER RATING"

Transcription

1 A joint government and industry program Licence No When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to: Invisi II 4.5/3 litre Inwall/Under Counter/ Induct/Inceiling Installation. 1.8 litre Single Flush Urinal Inwall/Under Counter/ Induct/Inceiling Installations. A 4.5/3 litre dual flush plastic cistern suitable for inwall, under counter, induct and inceiling applications. The cistern features a number of contemporary button design options with concealed fixing that are pneumatically operated for ease of operation and installation. The push buttons can be activated remotely up to 4 metres from the cistern, ideal for care and custom applications. The cistern incorporates Caroma Smartflush water saving technology. For installation flexibility the cistern, bracket and specially designed waste pipe have been developed to be installed in a standard 90mm metal or timber stud wall applications.the cistern is adjustable to 6/3 litre dual flush. Extended pneumatic hoses are additional and supplied separately Code No Alternatively the extended hose is also supplied with the Remote Mounting Box Kit Code No Invisi II Installations: Inwall The cistern can be fitted within a minimum cavity of 90mm with service access within the room via the standard or large button panel. A range of access panel kits are available to suit dual flush, single flush and remote push button positions. Under Counter The cistern can be fitted under counter with a minimum cavity depth of 90mm for front mount button installations and 100mm from the finished wall face to the counter's internal front face, for top mount button installations, as illustrated in Invisi II following pages (not suitable for urinals). Induct The cistern is suitable for behind the wall installations in a single service duct, as illustrated in following pages. Inceiling The cistern is suitable for mounting in the ceiling duct where access is provided for adjustment and servicing. This installation requires the fabrication of a using 40mm DWV and Flush Pipe Extension components contained in the Remote Mounting Box Kit Code No , as illustrated in following pages. Due to the high head height, only nominated Caroma boxed rim pans should be used with this installation. Invisi II Buttons Buttons and access plate are not included with the cistern, see following pages for available options. The more stars the more water efficient WATER RATING Water Consumption 1.8 litres per flush per stall For further information visit or call

2 Invisi II Inwall/Under Counter/Induct/Inceiling Cistern For wall faced pan applications, Code No For wall faced pan installations the cistern is simply mounted in position with the two brackets supplied which are screwed to the studwork. Invisi II Under Counter For wall hung pan applications, Code No The D.403 Invisi II WH Bracket is supplied for concrete floors or stud wall installations. Note: The bracket system is suitable for installation only where non compressible wall materials are used. Invisi II Inwall/Induct/Inceiling Cistern For wall hung pan applications, Code No The D.402 Invisi II WH Bracket is supplied for concrete floors or stud wall installations. Note: The bracket system is suitable for installation only where non compressible wall materials are used. Invisi II Structural Brick Wall For structural brick walls the cistern is fixed inwall and the wall hung pan is fixed using the D.788 Sanifix Bolt Through the Wall Bracket. Invisi II Urinal Single Flush: The Invisi II 3 star, 1.8 litre single stall urinal cistern is supplied with instructions for conversion to suit two stall and three stall, and 0.8 litre applications. A copper sparge adapter is included in place of a. Important: Working pressure is minimum 30kPa to maximum 1000 kpa flow pressure. Installation: Refer to Important Information for Plumbers section. Colours: White, chrome and satin chrome button options available, see following page Water inlet connection To centre line of buttons Note: Cistern height can be increased to 3m with additional extension kit (adjustable) 205 max. Studs 400mm 420mm flush pipe support For further information visit or call

3 Invisi II Buttons and Plates (suitable for cistern access) Invisi II Round Plate and Buttons Code No W Code No C Code No S Invisi II Rectangle Plate and Buttons Code No C Code No S Invisi II Round Care Plate and Raised Buttons Code No C Code No S Invisi II Rectangle Single Flush Plate and Button Code No C Code No S Invisi II Blank Access Plate Code No C Code No S Invisi II Custom Buttons (cistern requires alternative access) Ø67 78 Invisi II Round Custom Buttons Code No C Code No S Invisi II Rectangle Custom Buttons Code No C Code No S 78 Invisi II Round Single Flush Custom Button Code No C Code No S Invisi II Access Panel Options for Inwall Applications (Buttons supplied separately) 470 Invisi II Rectangle Single Flush Custom Button Code No C Code No S Ø67 Ø67 34 Invisi II Round Care Raised Buttons Code No C Code No S Large Access Panel Top Code No Large Access Panel Single Flush Bottom Code No Large Access Panel Blank Code No Note: Large access panels are recommended for double brick wall installations. Invisi II Remote Mounting Box Kit includes 2 x 4m pneumatic hose with extension componentsfor use with induct or remote mounted button installations. Code No m pneumatic hose. Code No (2 hoses required for remote dual flush installations) 6mm min. mm max. wall lining thickness 5mm min. mm max. wall thickness 5mm min. mm max. wall thickness Remote Button Plate Installation Standard button plate Installation Custom Button Installation 244 For further information visit or call

4 Under Counter Wall Faced Invisi II Smartflush Suite Installation 410 min. isolating valve supplied allows for side and back water connections 25 to top of support noggin A B C (+65 for Odourvac option suitable for front push only) Pan foot level Accurate positioning of the waste pipe relative to studwork is essential. Leda wall faced pan illustrated. A B C Cube Geo Leda Finished wall 90mm min. front button installation 100mm min. top button installation Top mount buttons Bench thickness mm max. for top push buttons Front mount buttons support Note: Access to cistern internals can be achieved through either front or top mount button plate option. Under Counter Wall Hung Invisi II Smartflush Suite Installation 410 min. isolating valve supplied allows for side and back water connections min. 915 min. for Odourvac option suitable for front push only Finished floor Accurate positioning of the waste pipe relative to studwork is essential. Metro wall hung pan illustrated. Cube 408 Walvit 405 Metro mm min. front button installation 100mm min. top button installation A Top mount buttons Front mount buttons Finished wall Bench thickness mm max. for top push buttons Note: The bracket system is suitable for installation only where non compressible wall materials are used. A Note: Access to cistern internals can be achieved through either front or top mount button plate option. For further information visit or call

5 Inwall Wall Faced Invisi II Smartflush Suite Installation Frame isolating valve supplied min. to underside of noggin and buttons 90 min. 6 min. max. wall thickness 25 to top of flush pipe support noggin 582 Supplied (adjustable from ) Supplied (adjustable from ) 395 Pan foot level support 185 Accurate positioning of the waste pipe relative to studwork is essential. Leda wall faced pan illustrated. Recommended 90 setout ( range) Note: Access to cistern internals can be achieved through button plate. Uniconnector Inwall Wall Hung Invisi II Smartflush Suite Installation Frame isolating valve supplied min. to underside of noggin and buttons 90 min. 6 min. max. wall thickness ref Finished floor Accurate positioning of the waste pipe relative to studwork is essential. Cube wall hung pan illustrated. Wall hung bracket suitable for structural slab or stud wall installation Spacer if required (not supplied) For 100mm UPVC DWV connection use Caroma Invisi II wall hung waste connector 170 max. from finished wall with Invisi II WH pan connector Note: The waste pipe must be accurately centralised in the cavity to achieve a minimum dimension of 90mm. Stud fixing bolt kit (not supplied) Note: Access to cistern internals can be achieved through button plate. Stud wall installation (for non-structural floor) Note: The bracket system is suitable for installation only where non compressible wall materials are used. 246 For further information visit or call

6 Induct Wall Faced Invisi II Smartflush Suite Installation isolating valve supplied 135 max. with flush pipe 5 min. max. wall lining thickness Remote mounted plate and buttons Service duct (Cistern to be installed backwards for service duct access) 25 to top of flush pipe support noggin 582 Supplied (adjustable from ) Supplied (adjustable from ) 395 Pan foot level Use extension kit for higher installation support Accurate positioning of the waste pipe relative to studwork is essential. Leda Wall Faced pan illustration. Uniconnector Recommended 90 setout ( range) Induct Wall Hung Invisi II Smartflush Suite Installation isolating valve supplied 5 min. max. wall lining thickness Remote mounted plate and buttons 135 max. with (Supplied) Service duct (Cistern to be installed backwards for service duct access) Wall hung bracket suitable for structural slab or stud wall installation (Use D788 for structural wall installation) 408 ref 0 Finished floor Accurate positioning of the waste pipe relative to studwork is essential. Cube Wall Hung pan illustrated. For 100mm UPVC DWV connection use Caroma Invisi II wall hung waste connector 170 max. from finished wall with Invisi II WH pan connector Structural Wall Installation (Option) Note: The waste pipe must be accurately centralised in the cavity to achieve a minimum dimension of 90mm. D788 Sanifix Bolt through wall bracket Code No Note: The bracket system is suitable for installation only where non compressible wall materials are used. For further information visit or call

7 Inceiling Wall Faced Invisi II Smartflush Suite Installation with Remote Mounting Box Kit Invisi II Flush Pipe Extension Kit 70mm Cavity (components supplied with Remote Mounting Box kit) Invisi II Flush Pipe Extension Kit 90mm Cavity (components supplied with Remote Mounting Box kit) Cistern Adaptor Kee Seal Breather Tube 40mm PVC DWV Pipe Cut to length and solvent weld (not supplied) 40mm 90 PVC DWV elbow (not supplied) 40mm PVC DWV Pipe Cut to length and solvent weld (not supplied) Cistern Adaptor Kee Seal Breather Tube 40mm PVC DWV Pipe Cut to length and solvent weld (not supplied) Flush pipe Adaptor Flush Pipe (with cistern) frame stopcock supplied 90 Invisi II cistern Ceiling void Ceiling access Where the ceiling space is restricted the Invisi II can be dropped into the wall cavity. 4 metres long (max.) pneumatic tube (Included with Remote Mounting Box kit) 40mm DWV fabricated Note: Minimum wall cavity 70mm if cistern is inceiling. 90mm if cistern is inwall cavity. 150mm if uniconnector is inwall cavity. 4.5 min. max. wall cladding thickness Remote mounted plate and buttons 3m max. Flush pipe extension kit to top of support noggin Recommended push button position Pan foot level support Leda Wall Faced pan illustrated. Uniconnector Recommended 90 setout ( range) For 100mm UPVC DWV connection use Caroma Uniconnector PVC adaptor Vinidex Code No For further information visit or call

8 4.5/3 Litre Toilet Suites For 4.5/3 litre the bucket is preset. Connect the pneumatic hoses to both the half flush and full flush positions. 4.5L 6/3 Litre Toilet Suites For 6/3 litre flush remove outlet valve from cistern and bucket (see below), refit outlet valve in cistern. Connect the pneumatic hoses to both the half flush and full flush positions. Cut the 4 tabs to remove bucket 1.8 Litre Single Flush Single Stall Urinal For 1.8 litre flush the bucket is preset. Connect the pneumatic hose to the full flush position. 0.8 Litre Single Flush Single Stall Urinal For the 0.8 litre flush adjust the bucket to the 0.8 litre mark. Adjust water level to appropriate mark on cistern tank. Connect the pneumatic hose to the full flush position. 3.8 Litre Single Flush TwoStall Urinal For 3.8 litre flush adjust the bucket to the 3.8 litre mark and reset the water level to the corresponding mark on the cistern tank. Connect the pneumatic hose to either flushing position. 1.8L 5.8 Litre Single Flush 3 Stall Urinal Conversion For 5.8 litre flush remove outlet valve from cistern and bucket (see below). Connect the pneumatic hose to either flushing position. Cut the 4 tabs to remove bucket For further information visit or call

9 Flush Pipe Extension Components (included in Remote Mounting Box Kit) Invisi II Flush Pipe Extension 90mm Cavity (components supplied with Remote Mounting Box Kit) Breather Tube Cistern Adaptor 40mm PVC DWV Pipe Cut to length and solvent weld to adaptors (not supplied) Flush pipe Adaptor (Supplied) Flush Pipe (with cistern) Kee Seal Invisi II Flush Pipe Extension 70mm Cavity (components supplied with Remote Mounting Box Kit) Kee Seal Breather Tube Cistern Adaptor 40mm PVC DWV Pipe Cut to length and solvent weld (not supplied) 40mm 90 PVC DWV elbow (Not supplied) 40mm PVC DWV Pipe Cut to length and solvent weld (not supplied) Breather Tube Outlet Valve Cistern Base 250 For further information visit or call

10 Inwall/Induct Urinal Invisi Invisi II II Installation Inwall Urinal Suite Frame isolating valve supplied 90mm min. cavity, 70mm min. for inceiling installation 6 min. max. wall thickness Finished wall Blank access panel 500 min. 335 to access panel Invisi II Cistern Reducer to Ø40 copper pipe Ø40 Flush pipe 18 Ø20 sparge pipe Single flush plate and button Vitreous China Grate 438 * 597 D.170 Concealed Fixing Bracket centre Finished floor standard 129 disabled * 650mm recommended standard height. 400mm recommended disabled height (no pedestal). Leda urinal illustrated. Induct Urinal Suite 5 min. max. wall lining thickness Service duct (Cistern to be installed backwards for service duct access) For further information visit or call

pricing and technical information caroma marc newson bathroom collection

pricing and technical information caroma marc newson bathroom collection pricing and technical information caroma marc newson bathroom collection collection one freestanding bath CMN8W, freestanding bath filler CMN92010C, shower mixer CMN92003C, rail shower with overhead CMN92008C3A,

More information

Our slimmest cistern. Sigma 75 concealed toilet cistern for back to wall pans

Our slimmest cistern. Sigma 75 concealed toilet cistern for back to wall pans Our slimmest cistern Sigma 75 concealed toilet cistern for back to wall pans Geberit concealed cisterns. Easy to install, tough and low maintenance. 75 mm Geberit has the most extensive product range of

More information

BATHROOM RANGE TOILETS BASINS SPAS BATHS TOILET SUITES

BATHROOM RANGE TOILETS BASINS SPAS BATHS TOILET SUITES BATHROOM RANGE 1 TOILETS SPAS BATHS inspiring choices for your bathroom CONTENTS 3 contents It s the stand-out fixtures that determine the style of a bathroom; the basin, the vanity, the toilet suite,

More information

PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design.

PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design. PARISI S Innovative Rimless Toilets feature the latest Technology in Flushing, Hygiene and Design. Powerful Clean The PARISI innovative rimless toilets are the first in Australia to ensure optimum hygiene

More information

What s new in toilets? Taller cisterns!

What s new in toilets? Taller cisterns! product update Feb 2014 What s new in toilets? Taller s!.com.au maxim II STO-17 position 745mm replaces maxim STO-10W-S lagoa II STO-16 position 745mm replaces lagoa STO-10W limni II STO-15 position 745mm

More information

Concealed Flushing and Installation Systems. PERFORMANCE AND INNOVATION

Concealed Flushing and Installation Systems. PERFORMANCE AND INNOVATION Concealed ing and Installation Systems. PERFORMANCE AND INNOVATION 2 Thinking about saving water? Think GROHE. 3 Water, our most vital resource. Few people realize how much water they flush down their

More information

Geberit Duofix. Need a frame for every application? There s a Geberit for it.

Geberit Duofix. Need a frame for every application? There s a Geberit for it. Geberit Duofix Need a frame for every application? There s a Geberit for it. We ve got it covered The smart way to install sleek modern looking wall-hung toilets is with Geberit Duofix frame systems. Neatly

More information

SYSTEMS IDEAL FOR YOUR PROJECT SANITARY SYSTEMS STRENGTH YOU CAN TRUST

SYSTEMS IDEAL FOR YOUR PROJECT SANITARY SYSTEMS STRENGTH YOU CAN TRUST SANITARY SYSTEMS SANITARY SYSTEMS HOTELS OFFICES SYSTEMS IDEAL FOR YOUR PROJECT COMPRESSION WASTE TRAPS WC CONNECTORS FLOOR DRAINAGE SANITARY SYSTEMS STRENGTH YOU CAN TRUST HOSPITALS & CARE HOMES SCHOOLS

More information

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC TABLE OF CONTENTS Pictorial Index Product Recommendations Water Closet Carriers Matching Water Closet & Carrier Closet Carrier Selection & Battery Set-Up Stud & Nipple Adjustment to Finished Wall Anchoring

More information

Appendix 4. Bills of Quantities

Appendix 4. Bills of Quantities Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic

More information

BOQ for Plumbing, Sanitary Works

BOQ for Plumbing, Sanitary Works BOQ for Plumbing, Sanitary Works Page of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) SANITARY FIXTURES a Providing & Fixing star white colour vitreous china wall mounted wc with heavy duty

More information

Duravit Vero toilet with Geberit Monolith in White Glass. Geberit Product Catalog May 2013

Duravit Vero toilet with Geberit Monolith in White Glass. Geberit Product Catalog May 2013 Duravit Vero toilet with Geberit Monolith in White Glass Geberit Product Catalog May 2013 Table of Contents Geberit Installation Systems Product features, installation scenarios, system components Page

More information

Technology. Enabling Design. Geberit Duofix Carrier

Technology. Enabling Design. Geberit Duofix Carrier Technology Enabling Design Geberit Duofix Carrier Geberit is Behind It All! With millions of installations throughout the world, the message is clear: the Geberit Duofix Carrier allows unique design without

More information

1.04 SUBMITTALS PLUMBING FIXTURES

1.04 SUBMITTALS PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

The ultra-low profile shower deck that s both stylish and easy to fit

The ultra-low profile shower deck that s both stylish and easy to fit The ultra-low profile shower deck that s both stylish and easy to fit for wet rooms you can trust Designed with YOU in mind As a home-owner you will appreciate the new aqua4ma linear Shower Deck for its

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 40 00_PLUMBING FIXTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Water closets. 2. Urinals. 3. Lavatories. 4. Sinks. 5.

More information

Typical detail: New roof with breathable underlay

Typical detail: New roof with breathable underlay New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop

More information

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

THE INSTALLING INSTRUCTION FOR CONCEALED TANK THE INSTLLING INSTRUCTION FOR CONCELED TNK Important remind: 80mm300kgf FFL ccessories List:. Please read through this Instructions carefully prior to installation, and our company shall not be responsible

More information

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems. PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,

More information

Installation Instructions

Installation Instructions For Bar Mixers & Bath Shower Mixers Installation Instructions Installers please note these instructions are to be left with the user 2180388E June 2008 CONTENTS Page Introduction 1 Safety warnings 1 Main

More information

K FAIRFAX BATH & SHOWER TRIM SET ALSO K-T12007, K-12014, K-T Codes/Standards Applicable Specified model meets or exceeds the following:

K FAIRFAX BATH & SHOWER TRIM SET ALSO K-T12007, K-12014, K-T Codes/Standards Applicable Specified model meets or exceeds the following: Features Metal construction Brass valve bodies Rite-Temp pressure-balancing diaphragm design High-temperature limit setting for added safety Pressure-balancing mechanism of one-piece diaphragm cartridge

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount Revised Schedule B as per corrigendum no. SASB/NIT/Works/818/2016/09 dated 28.01.2016. SCHEDULE B (FINANCIAL BID) B- a FABRICATION AND SUPPLY OF 200 EUROPEAN TYPE TOILETS (Rate to be quoted in Rupees both

More information

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A SPECIFICATIONS AND SCHEDULE OF QUANTITIES Name of work: Renovation of toilets in main building near molecular biology lab Sl Rate Amount Schedule A 1 Demolishing concrete in cement mortar including disposal

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES SECTION 15440 - PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, are a part of this Section. 1.02 SUMMARY A.

More information

Air flue duct for use with ecotec boilers

Air flue duct for use with ecotec boilers For the installer Flue installation instructions Air flue duct for use with ecotec boilers Concentric System Ø 80/5 (Galvanized steel air duct/plastic flue duct) GB Contents Notes on the documentation

More information

has been built on the quality of what we do. Today, Caroma is one of the nation s most recognised and trusted names.

has been built on the quality of what we do. Today, Caroma is one of the nation s most recognised and trusted names. bathrooms We ve come a long way. In 70 years of creating and styling Australian bathrooms, our reputation has been built on the quality of what we do. Today, Caroma is one of the nation s most recognised

More information

In-Wall Tank and Bowl Carrier System With Dual Flush Technology Geberit Model No Flush Volume: 1.6 / 0.8 GPF / 3.

In-Wall Tank and Bowl Carrier System With Dual Flush Technology Geberit Model No Flush Volume: 1.6 / 0.8 GPF / 3. D400-00 07-00 965.94.00.0 (00) In-Wall Tank and owl Carrier System With Dual Flush Technology Geberit Model No..78.00. Flush Volume:.6 / 0.8 GPF - 6.0 /.0 LPF Product Data Product Specifications - For

More information

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work

More information

Element D Services Plumbing

Element D Services Plumbing Fixtures PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses plumbing fixtures, trim and associated accessories. Refer to MD Anderson Cancer Center Master Construction Specification Sections for additional

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

W i s d o m S m a r t C o l l e c t i o n. Aristotle series

W i s d o m S m a r t C o l l e c t i o n. Aristotle series W i s d o m S m a r t C o l l e c t i o n Aristotle series 8490mm Aristotle 16 Area Calculations ARIstotle 16 Itemised Floor Areas Ground Floor Garage Porch Outdoor Leisure Area 118.22 sqm 20.04 sqm 1.53

More information

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers. SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping

More information

Affordable Quality - Easy Build. Building Specifications. Kitset Homes. latitudehomes.co.nz

Affordable Quality - Easy Build. Building Specifications. Kitset Homes. latitudehomes.co.nz Building Specifications Kitset Homes KITSET MATERIAL & SERVICE LIST (specifications are subject to change from time to time) PERMIT PLANS Permit Plans Ready to submit to local council based on information

More information

Basic Measuring and Calculations. Formulas, Workings Hints and Tips

Basic Measuring and Calculations. Formulas, Workings Hints and Tips Basic Measuring and Calculations Formulas, Workings Hints and Tips Start by writing down the formula When working out mathematics Ensure you show all working out (Marks will be awarded for working out)

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

W i s d o m S m a r t C o l l e c t i o n. Inspiration series

W i s d o m S m a r t C o l l e c t i o n. Inspiration series W i s d o m S m a r t C o l l e c t i o n Inspiration series Inspiration 30 Area Calculations INSPIRATION 30 This home has 13.5 been designed to fit a m lot width 11510mm Itemised Floor Areas Garage Porch

More information

Schluter -KERDI-DRAIN

Schluter -KERDI-DRAIN Schluter -RONDEC Finishing and edge-protection profile with a rounded reveal surface. Schluter -RONDEC is a finishing and edge-protection profile for tiled edges and outside corners of tiled surfaces.

More information

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these

More information

Contents Overview. Pipe. Fittings. Features & benefits. Installation considerations. Tools & terminology

Contents Overview. Pipe. Fittings. Features & benefits. Installation considerations. Tools & terminology pexplus manual 1 pexplus Contents 2 3-6 7 8 8-11 12 13-16 17-18 19-25 Overview Pipe Fittings Features & benefits Installation considerations Tools & terminology Jointing instructions FAQ Pex fitting range

More information

BUILD A SHOWER CUBICLE

BUILD A SHOWER CUBICLE BUILD A SHOWER CUBICLE Building a shower cubicle requires some experience in carpentry and tiling. You also need a degree of expertise in wiring and plumbing in order to install a shower unit. By all means

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

Child Friendly Schools in Rwanda

Child Friendly Schools in Rwanda Child Friendly Schools in Rwanda Typical drawings of school building and toilet block Approved by MINEDUC/UCEFS Eng. Warren Habimana UNICEF Rwanda PO Box 381, Kigali Education section: tel. +250 592750-55

More information

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red Plant Areas External plant must meet the following noise suppression requirement as adopted by the Landlord: 1. Air handling units 45db measured at 3metres from source. 2. Heat rejection plant 45db measured

More information

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies. Place D Orléans Transitway Section 10 11 35 1231 Place D Orléans Dr, Ottawa, ON. SLIDING DISPLAY BACKDROPS City of Ottawa Project No. CR008042 Page 1 of 2 1 GENERAL 1.01 REFERENCES.1 Underwriters' Laboratories

More information

RD6000 Kitchen Range

RD6000 Kitchen Range RD6000 Kitchen Range Water, life s essential ingredient Raindance water filter systems provide an unlimited supply of pure, clean and healthy water for less than the cost of bottled water. Raindance drinking

More information

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

Engineering Design Center. Standard Drawings. 1st Edition -January 2016 Engineering Design Center Standard Drawings 1st Edition -January 2016 Golden State Water Company Standard Drawings 1/11/2016 Table of Contents PART A STANDARD DRAWINGS Section I Pipeline Construction P-1

More information

Rediflow Concrete Gas Flue System

Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow Concrete Gas Flue System Rediflow the complete gas flue block system Red Bank s range of Rediflow pre-cast concrete gas flue block system manufactured to BS EN

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

NEW CODE DESCRIPTION PART NO LIST PRICE CODE DESCRIPTION PART NO LIST PRICE LIST PRICES EFFECTIVE. Vogue. F & P Wholesale.

NEW CODE DESCRIPTION PART NO LIST PRICE CODE DESCRIPTION PART NO LIST PRICE LIST PRICES EFFECTIVE. Vogue. F & P Wholesale. 80 BOILERS NATURAL GAS Ideal Vogue Combi Ideal Vogue System CODE DESCRIPTION PART NO CURRENT LIST LIST PRICE PRICES CODE DESCRIPTION PART NO CURRENT LIST LIST PRICE PRICES COMBI OCTOBER 2016 NOVEMBER 2016

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Passive chilled beams QPVA and QPBA

Passive chilled beams QPVA and QPBA Passive chilled beams QPVA and QPBA Functions Cooling Controls The Flexicool QPVA and QPBA passive chilled beams provide for the cooling in a room. QPVA (width 570 mm ) and QPBA (width 430 mm ) are broad

More information

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

BUILDING SKILLS. Building Skills : Basic Painting. Building Skills : Plaster & Tiler. Course Content : Course Content : Duration : 10 Days

BUILDING SKILLS. Building Skills : Basic Painting. Building Skills : Plaster & Tiler. Course Content : Course Content : Duration : 10 Days Building Skills : Basic Painting Use and maintain hand tools Prepare new wall surfaces Prepare old wall surfaces Coat new wall surface with P. V. A Prepare wooden & metal surface (Door & Frame) for enamel

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Crimp-ON Pex Plumbing System

Crimp-ON Pex Plumbing System WATER & GAS DR BRASS stainless steel sleeve witness opening double o Ring Crimp-ON Pex Plumbing System August 2011 09 Oschin Bush O-Ring Crimp DL brochure.indd 1 2/08/11 4:56 PM ELSON proudly presents

More information

Keylar Shelving (QLD) Pty Ltd

Keylar Shelving (QLD) Pty Ltd Wall Strip Shelving Garage Option This product requires some assembly Wall Strip Shelving is an economical way of providing wall mounted shelving for any light duty application and is for indoor use only.

More information

This consumes a high amount of space, and exacerbates the susceptibility of fully ventilated stacks to rapid pressure changes.

This consumes a high amount of space, and exacerbates the susceptibility of fully ventilated stacks to rapid pressure changes. Trickle-Down effect: Understanding the latest, space-saving developments in water management Introduction Plumbing and sanitary systems are a central part of any building project, and consume significant

More information

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards Laboratory Standards These criteria include general planning guidelines. They are intended for use of Designers during the design phases of the project. Planning Assumptions Overview In order to maximize

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

+44 (0)

+44 (0) Greenlee processing tools make your workshop mobile. This makes you much more flexible and efficient in plant and control cabinet construction. Friedrich Reusch 582 Special cutting tools 584 Machining

More information

Toggle Adjustable Tables Price List. August 20, 2014 Updated March 25,

Toggle Adjustable Tables Price List. August 20, 2014 Updated March 25, Toggle Adjustable Tables Price List August 20, 2014 Updated March 25, 2015 800-424-2432 2 General Information TOGGLE TABLE Laminate; 1-1/4" round vinyl bullnose edge; 1-1/2" radius corner (54B) Laminate;

More information

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions. SECTION 07710 MANUFACTURED ROOF SPECIALTIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof drains for new roofing. B. Roof drains for reroofing. C. Roof drains for retrofitting into existing roof drains.

More information

FLUE KIT INSTALLATION MANUAL

FLUE KIT INSTALLATION MANUAL FLUE KIT INSTALLATION MANUAL 7 76 9 55 ROOM SEALED TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR USE WITH WORCESTER GREENSTAR GAS-FIRED APPLIANCES: Greenstar FS

More information

Drainage and Erosion Control

Drainage and Erosion Control Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Know-how from Switzerland

Know-how from Switzerland Know-how from Switzerland Geberit. Swiss Know-How and Sustainability. Who wouldn t appreciate more space in the bathroom? Nothing says luxury more than a well designed bathroom. A concealed cistern will

More information

SECTION VIBRATION ISOLATION

SECTION VIBRATION ISOLATION SECTION 15240 VIBRATION ISOLATION PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15450 - Plumbing Equipment. 2. 15510 - Piping (HVAC). 3. 15515 Valves, Hangers, and Specialties. 4. 15540 - Pumping

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT Page 220529-1 SECTION 220529 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Terrain HDPE. Product Guide

Terrain HDPE. Product Guide TAGIG1-PT JULY 2009 Terrain HDPE Product Guide Terrain HDPE BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE No. 07/4479 A modern high density polyethylene system with many advantages over cast iron and other

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

Concrete Slab-on-Ground

Concrete Slab-on-Ground Concrete Slab-on-Ground This training package provides information on concrete slab-on-ground construction, including reinforcement, formwork, mix, placement and curing, for village infrastructure and

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

RD01 WHAT S IN THE BOX INSTALLATION MANUAL

RD01 WHAT S IN THE BOX INSTALLATION MANUAL INSTALLATION MANUAL RD0 WHAT S IN THE BOX Rain Director control panel with mode indicators, programming buttons and control valves and 0 V AC to V wall adapter. Control panel measures 80mm W x 70mm H x

More information

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypLyner (walls) Metal framed wall lining system. GypLyner. GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal

More information

Wet Room Floor Solutions

Wet Room Floor Solutions Wet Room Floor Solutions The Benefits of UniSlope Wet Room systems Luxurious Lifestyle Open plan bathroom that creates a more attractive space. Complements contemporary design. UniSlope Highline Custom

More information

ANNEXURE B SECTION 1

ANNEXURE B SECTION 1 ANNEXURE B SECTION 1 HOUSING SPECIFICATIONS 1. Houses 1.1. Roofs Material: Architect approved concrete tiles @ 17,5 degree pitch on SABS approved underlay Colour: As per Architects. 1.2. Rainwater goods

More information

Assembly Instruction. FLAMRO Variant N II A / N II KS

Assembly Instruction. FLAMRO Variant N II A / N II KS Assembly Instruction / N II KS Please respect the permit specifications. All documents may be downloaded from www.flamro.com/services/downloads. It is assumed that - any damage to the seal will be repaired

More information

W i s d o m S m a r t C o l l e c t i o n. Newton series

W i s d o m S m a r t C o l l e c t i o n. Newton series W i s d o m S m a r t C o l l e c t i o n Newton series 9160mm Newton 18 Area Calculations Itemised Floor Areas Area Ground Floor 141.98 sqm 21.56 sqm Porch 2.27 sqm 165.81 sqm 17.7 sq Optional Alfresco

More information

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth P33 Zero Clearance Direct Vent Gas Fireplace P33 WITH THE FLUSH OR BAY FRONT Model P33-NG4 P33-LP4 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure

More information

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions. 15240 VIBRATION ISOLATION ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 230548 An optional keynote

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual 1 1 Introduction This manual gives guidance on how to install the CPM Group Perfect manhole system

More information

Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision.

Design. Boral CinemaZone Fact Sheet. Windows. Acoustic sealants. Sound absorptive panels. Ventilation. Floor coverings. The vision. Windows Like doorways, windows can be a significant source of sound leakage. For maximum isolation, windows should either be removed or built over internally - leaving the house facade unaffected. If natural

More information

How to fill in your Timber Frame Order Form

How to fill in your Timber Frame Order Form How to fill in your Timber Frame Order Form 1 General Would you like us to check slab or design the building to Architects drawings? Check Slab: Is the Slab in place already, if so has your architect checked

More information

RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) OF THR 8th PRIMARY SCHOOL TOILETS IN MYTILENE. Annex A - BILL OF QUANTITIES 1/9

RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) OF THR 8th PRIMARY SCHOOL TOILETS IN MYTILENE. Annex A - BILL OF QUANTITIES 1/9 RFP/GRC/LSV/2017-005: RENOVATION (CIVIL WORKS) OF THR 8th PRIMARY SCHOOL TOILETS IN MYTILENE Annex A - BILL OF QUANTITIES 1/9 The Contractor shall consider in his price all costs or expenses of all requirements

More information

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting MARKETING PROPERTY-PROJECT SERVICES STD - D905 VOLUME 2 Service Station Construction SPECIFICATION Section 10 Rendering, Plasterboard & Fibre Cement Sheeting Index 10.1 Extent of Work 10.2 Rev 07.8 General

More information

SI T T FST

SI T T FST SI 440-600-700-700T-780-780T-900-1100 Freestanding TAPER TOP Open Fire - Wood Burner Installation Instructions Note: FLUE SYSTEMS Casing. Flue System may require to be Doubled Lined to Comply. Ref ASNZS:2918:2001

More information

SECTION PLUMBING PIPING SYSTEMS

SECTION PLUMBING PIPING SYSTEMS SECTION 15300 PLUMBING PIPING SYSTEMS PART 1 - GENERAL 1.01 SPECIAL NOTICE A. Each contractor shall read all relevant documents, become familiar with the job, the scope of work, type of general construction,

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm) Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

TECHNICAL INFORMATION SHEET NUMBER 1a

TECHNICAL INFORMATION SHEET NUMBER 1a BASIC BUILDING REQUIREMENTS FOR THE CONSTRUCTION OF TRADITIONAL SQUASH COURTS Building Requirements The dimensions of a singles or doubles court is shown on the attached diagram. Width and length of the

More information

PH6000. Key Features

PH6000. Key Features Phenolic Locker Series PH6000 Key Features ½ inch doors and end panels Durable, backed by a 20 year warranty. Ideal choice for wet-use areas including pools and recreation centers Graffiti resistant, permanent

More information