LOCATION MAP SCALE: 1" = 80 INDEX OF SHEETS

Size: px
Start display at page:

Download "LOCATION MAP SCALE: 1" = 80 INDEX OF SHEETS"

Transcription

1 P 9 ST ST W W DR E E E SLAS MELROSE MELROSE ELMORE ADDITION pg WALFORD ELMORE LAMONT CLEVELAND FCGS SCHOOL LOT ELMORE LAMONT COURT PLAYGROUND ENCHMARKS (NAVD 1988) M #1 "X" SET IN SOUTHEAST OLT OF FIRE HYDRANT ±2' WEST OF CLEVELAND. ELEV.= RESERVE EDDINGTON DR LANTERN DR M #2 " "CHISELED ON NORTH SIDE OF LIGHT POLE ASE IN THE A&W PARKING LOT, 200' WEST OF CLEVELAND. ELEV.= GREENWICH DERYSHIRE FCGS 1671 CHADWICK DR SPECIFICATIONS FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\TITLE SHEET-PLAN SET.DWG" : SD "5/30/ :17 AM" LAYOUT "DOSD - TITLE" : PRINTED "6/5/2017 8:55 AM" COTA PR LOCATION MAP NO SCALE STANDARD CONSTRUCTION DRAWINGS /1/ /1/ /1/ /1/ /1/ /1/13 S.S.23 2/17/ /1/13 AA-S102 AA-S112 AA-S125A AA-S133A AA-S139 AA-S142 AA-S149 AA-S1 PLAN PREPARED Y: CT TRRS DARRELL S. MILLER REGISTERED ENGINEER LOCATION MAP SCALE: 1" = 80 SITE CIVIL PLANS NUMER 17-MAY INDEX OF SHEETS TITLE SHEET C1.01 GENERAL NOTES C2.01 GENERAL NOTES C2.02 TYPICAL DETAILS C3.01 TYPICAL DETAILS ALTERNATE C3.01A MAINTENANCE OF TRAFFIC PLAN C3.02 MAINTENANCE OF TRAFFIC NOTES C3.03 EXISTING SITE LAYOUT C4.01 DEMOLITION PLAN C5.01 PAVING PLAN C6.01 PAVING PLAN ALTERNATE C6.01A CC-PLANS STORM TITLE SHEET C7.01 PROPOSED PLAN C7.02 PARKING LOT GRADING PLAN C7.03 STORM SEWER PROFILE SHEET C7.04 STORMTECH DETAILS C7.05 STORMTECH AND MANHOLE DETAILS C7.06 STORMWATER POLLUTION PREVENTION PLAN C7.07 STORMWATER POLLUTION PREVENTION NOTES C7.08 STORMWATER POLLUTION PREVENTION PLAN DETAILS C7.09 LANDSCAPING PLANS PLANTING PLAN L1.01 KEY LAYOUT PLAN L2.01 LAYOUT PLAN ENLARGEMENT L2.02 LAYOUT PLAN ENLARGEMENT L2.03 MATERIALS PLAN L3.01 LANDSCAPE DETAILS L4.01 LANDSCAPE DETAILS L4.02 SIGN DETAILS L4.03 ELECTRICAL PLANS ELECTRICAL NOTES E1.01 ELECTRICAL SITE LAYOUT E2.01 ELECTRICAL DETAILS E3.01 APPROVALS: SIGNATURES ELOW SIGNIFY ONLY CONCURRENCE WITH THE GENERAL PURPOSE AND GENERAL LOCATION OF THE PROJECT. ALL TECHNICAL DETAILS REMAIN THE RESPONSIILITY OF THE ENGINEER PREPARING THE PLANS. CITY ENGINEER/ADMINISTRATOR, DIVISION OF DESIGN AND CONSTRUCTION ADMINISTRATOR, DIVISION OF POWER ADMINISTRATOR, DIVISION OF WATER ADMINISTRATOR, DIVISION OF SEWERAGE & DRAINAGE RELATED PLAN SETS: DRAWER E: 3163-E PRELIMINARY SITE COMPLIANCE: FINAL SITE COMPLIANCE: COUNTY ENGINEER, FRANKLIN COUNTY CHIEF DEPUTY ENGINEER, FRANKLIN COUNTY THE CONSTRUCTION AND MATERIALS SPECIFICATIONS (CMSC), 2012 EDITION INCLUDING ALL SUPPLEMENTS THERETO, SHALL GOVERN ALL CONSTRUCTION ITEMS THAT ARE A PART OF THIS PLAN UNLESS NOTED OTHERWISE. DEVELOPER/ CENTRAL OHIO TRANSIT AUTHORITY 33 N. HIGH STREET COLUMUS, OH. 432 CONTACT: RIAN WEISS WEISSD@COTA.COM Matt Selhorst COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT ADDRESS: 3573 CLEVELAND. NOI PERMIT # SCALE: NONE SHEET: C1.01 SITE COMPLIANCE PLAN # P (614) F (614) Darrell Miller, PE Know what's R

2 FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\GEN_NOTES.DWG" : SD "5/17/2017 2:59 PM" LAYOUT "GEN NOTES" : PRINTED "6/5/2017 8:55 AM" 432 P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT GENERAL NOTES SCALE:NONE SHEET: C2.01 SITE COMPLIANCE PLAN #

3 FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\GEN_NOTES.DWG" : SD "5/17/2017 2:59 PM" LAYOUT "GEN NOTES (2)" : PRINTED "6/5/2017 8:55 AM" 432 P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT GENERAL NOTES SCALE: NONE SHEET: C2.02 SITE COMPLIANCE PLAN #

4 ASE ID FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\TYP_SECTIONS.DWG" : SD "5/17/2017 7:55 AM" LAYOUT "TYPICAL SECTIONS" : PRINTED "6/5/2017 8:55 AM" IORETENTION ESTIMATE OF QUANTITIES ITEM UNIT TOTAL PAY ITEM PLANTING SOIL CY* 143 SPECIAL SAND CY STONE DIAPHRAGM CY AGGREGATE CY FARIC SY UNDERDRAIN LF P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT TYPICAL DETAILS SCALE: NONE SHEET: C3.01 SITE COMPLIANCE PLAN #

5 ALTERNATE ID #1 FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\TYP_SECTIONS ALTERNATE.DWG" : SD "5/17/2017 6:59 AM" LAYOUT "TYPICAL SECTIONS" : PRINTED "6/5/2017 8:55 AM" IORETENTION ESTIMATE OF QUANTITIES ITEM UNIT TOTAL PAY ITEM PLANTING SOIL CY* 143 SPECIAL SAND CY STONE DIAPHRAGM CY AGGREGATE CY FARIC SY UNDERDRAIN LF P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT TYPICAL DETAILS ALTERNATE SCALE: NONE SITE COMPLIANCE PLAN # SHEET: C3.01A

6 WALFORD STREET CLEVELAND NUE LEGEND N SIGN DETAILS PRIVATE DRIVE FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\MOT PLAN.DWG" : SD "5/17/2017 2:56 PM" LAYOUT "MOT" : PRINTED "6/5/2017 8:55 AM" NORTHERN LIGHTS SHOPPING CENTER CLEVELAND NUE 432 P (614) F (614) PROJECT TITLE: COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT MOT PLAN SCALE:1"=" SHEET: C3.02 CONTRACT DRAWING NO. Know what's R

7 FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\MOT PLAN.DWG" : SD "5/17/2017 2:56 PM" LAYOUT "MOT-NOTES" : PRINTED "6/5/2017 8:55 AM" 432 P (614) F (614) PROJECT TITLE: COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT MOT NOTES SCALE:NONE SHEET: C3.03 CONTRACT DRAWING NO.

8 ELMORE. WALFORD STREET N EX. CAR WASH & DRIVE THRU FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\SITE LAYOUT_SHT.DWG" : SD "5/30/ :26 AM" LAYOUT "EX. LAYOUT" : PRINTED "6/5/2017 8:56 AM" W ST S G LEGEND PRIVATE DRIVE PRIVATE DRIVE NORTHERN LIGHTS SHOPPING CENTER 432 P (614) F (614) LEE'S AUTO SALES & SERVICE COTA RT - NORTHERN LIGHTS PARK AND RIDE LOT EXISTING SITE LAYOUT CLEVELAND NUE PROJECT AREA MAP (NO SCALE) SCALE:1"=40" SHEET: C4.01 SITE COMPLIANCE PLAN # Know what's R

9 N FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\DEMO PLAN.DWG" : SD "5/30/2017 9:31 AM" LAYOUT "DEMO PLAN" : PRINTED "6/5/2017 8:56 AM" 432 P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT DEMOLITION PLAN 0 30 SCALE: 1" = 30' SHEET: C5.01 SITE COMPLIANCE PLAN #

10 ASE ID N FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\ROLLER COMPACTED CONCRETE PLAN.DWG" : SD "5/30/2017 9:31 AM" LAYOUT "PROP. LAYOUT" : PRINTED "6/5/2017 8:56 AM" COORDINATE TALE POINT # NORTHING EASTING COORDINATE TALE POINT # NORTHING EASTING P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT PAVING PLAN SCALE:1"=20' Know what's SITE COMPLIANCE PLAN # SHEET: C6.01 R

11 ALTERNATE ID #1 N FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\ALTERNATE PAVING PLAN.DWG" : SD "5/30/2017 9:31 AM" LAYOUT "PROP. LAYOUT" : PRINTED "6/5/2017 8:56 AM" P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT PAVING PLAN ALTERNATE SCALE:1"=20' Know what's SITE COMPLIANCE PLAN # SHEET: C6.01A R

12 PLAYGROUND DR E E ESTIMATE OF QUANTITIES WALFORD ST ELMORE LAMONT W MELROSE W FCGS 1668 SCHOOL LOT LAMONT E MELROSE ELMORE CLEVELAND COURT LANTERN DR EDDINGTON DR DERYSHIRE FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\CC PLAN SET\TITLE SHEET- CC PLAN SET.DWG" : SD "5/30/ :18 AM" LAYOUT "DOSD - TITLE" : PRINTED "6/5/2017 8:56 AM" LOCATION MAP NO SCALE ENCHMARKS (NAVD 1988) M #1 "X" SET IN SOUTHEAST OLT OF FIRE HYDRANT ±2' WEST OF CLEVELAND. ELEV.= M #2 " "CHISELED ON NORTH SIDE OF LIGHT POLE ASE IN THE A&W PARKING LOT, 200' WEST OF CLEVELAND. ELEV.= SPECIFICATIONS THE CONSTRUCTION AND MATERIALS SPECIFICATIONS (CMSC), 2012 EDITION INCLUDING ALL SUPPLEMENTS THERETO, SHALL GOVERN ALL CONSTRUCTION ITEMS THAT ARE A PART OF THIS PLAN UNLESS NOTED OTHERWISE. DEVELOPER/ CENTRAL OHIO TRANSIT AUTHORITY 33 N. HIGH STREET COLUMUS, OH. 432 CONTACT: RIAN WEISS WEISSD@COTA.COM Matt Selhorst P (614) F (614) Darrell Miller, PE PLAN PREPARED Y: STANDARD CONSTRUCTION DRAWINGS /1/ /1/14 S.S.23 2/17/ /1/ /1/ /1/ /1/ /1/13 CONTROL/OUTLET STRUCTURE NO. NOI PERMIT # DARRELL S. MILLER REGISTERED ENGINEER AA-S102 AA-S133A AA-S142 AA-S NUMER 17-MAY-2017 INDEX MAP SCALE: 1" = 100' SITE DATA TALE TOTAL SITE AREA: TOTAL DISTURED AREA: PRE-DEVELOPED IMPERVIOUS POST-DEVELOPED IMPERVIOUS APPROVALS: SIGNATURES ELOW SIGNIFY ONLY CONCURRENCE WITH THE GENERAL PURPOSE AND GENERAL LOCATION OF THE PROJECT. ALL TECHNICAL DETAILS REMAIN THE RESPONSIILITY OF THE ENGINEER PREPARING THE PLANS. APPROVAL FOR STORM SEWERS ONLY. CITY ENGINEER/ADMINISTRATOR, DIVISION OF DESIGN AND CONSTRUCTION ADMINISTRATOR, DIVISION OF POWER ADMINISTRATOR, DIVISION OF WATER ADMINISTRATOR, DIVISION OF SEWERAGE & DRAINAGE AC 1.74 AC 1.36 AC 1.09 AC RELATED PLAN SETS: DRAWER E: 3163-E SITE COMPLIANCE: SUMMARY OF POST-CONSTRUCTION STORMWATER CONTROL FACILITIES AA-S112 AA-S125A AA-S139 AA-S1 PLAN VIEW AND DETAIL PAGE NUMERS FOR MP CONTROL FUNCTION DRAINAGE AREA TO CONTROL FACILITY (ACRES) 1 C5.02,C8.03 FLOOD CONTROL FACILITY TYPE STORMTECH CHAMERS 2 C5.02 WATER QUALITY ISOLATOR ROW COUNTY ENGINEER, FRANKLIN COUNTY CHIEF DEPUTY ENGINEER, FRANKLIN COUNTY GREEN INFRASTRUCTURE (SQUARE FEET) 3 C3.01,C5.02 WATER QUALITY IORETENTION 2702 LOCATION STORMTECH CHAMERS INDEX OF SHEETS TITLE SHEET C7.01 PARKING PLAN C7.02 PARKING LOT GRADING PLAN C7.03 STORM SEWER PROFILE SHEET C7.04 STORMTECH DETAILS C7.05 STORMTECH AND MANHOLE DETAILS C7.06 STORMWATER POLLUTION PREVENTION PLAN C7.07 STORMWATER POLLUTION PREVENTION NOTES C7.08 STORMWATER POLLUTION PREVENTION PLAN DETAILS C YEAR DETENTION TALE VOLUME REQUIRED (AC-FT) VOLUME USED (AC-FT) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT SCALE: NONE SHEET: C7.01 CONTRACT DRAWING NO. CC ELEVATION Know what's R

13 N FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\SITE LAYOUT_SHT.DWG" : SD "5/30/ :26 AM" LAYOUT "PROP. LAYOUT" : PRINTED "6/5/2017 8:57 AM" CROSSWALK DETAIL N.T.S. A A 432 P (614) F (614) COTA RT - NORTHERN LIGHTS PARK AND RIDE LOT PROPOSED SITE LAYOUT CLEVELAND NUE SCALE:1"=20' Know what's SITE COMPLIANCE PLAN # SHEET: C7.02 R

14 N FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\SITE GRADING.DWG" : SD "5/30/ :16 AM" LAYOUT "PROP. LAYOUT" : PRINTED "6/5/2017 8:57 AM" PRIVATE DRIVE P (614) F (614) CLEVELAND NUE COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT PARKING LOT GRADING PLAN SCALE:VARIES SITE COMPLIANCE PLAN # Know what's SHEET: C7.03 R

15 FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\PROFILE_SHT.DWG" : SD "5/30/ :16 AM" LAYOUT "LAYOUT (1)" : PRINTED "6/5/2017 8:57 AM" 432 P (614) F (614) COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT STORM SEWER PROFILE SHEET

16 MATERIAL LOCATION D C A AASHTO M43 DESIGNATION DESCRIPTION FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE OTTOM OF FLEXILE PMENT OR UNPD FINISHED GRADE AOVE. NOTE THAT PMENT SUASE MAY E PART OF THE 'D' LAYER. ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PMENT SUGRADE REQUIREMENTS. FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMEDMENT STONE ('' LAYER) TO 24" [610 mm] AOVE THE TOP OF THE CHAMER. NOTE THAT PMENT SUASE MAY E A PART OF THIS LAYER. GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, < 35% FINES. MOST PMENT SUASE MATERIALS CAN E USED IN LIEU OF THIS LAYER. EMEDMENT STONE SURROUNDING THE CHAMERS FROM THE FOUNDATION STONE TO THE 'C' LAYER AOVE. FOUNDATION STONE ELOW CHAMERS FROM THE SUGRADE UP TO THE FOOT (OTTOM) OF THE CHAMER. COMPACTION/DENSITY REQUIREMENT PREPARE PER ENGINEER'S PLANS. PD INSTALLATIONS MAY H STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 CLEAN, CRUSHED, ANGULAR STONE, NOMINAL SIZE DISTRIUTION ETWEEN 3/4-2 INCH [19-51 mm] MIN. VOID SPACE = 40% CLEAN, CRUSHED, ANGULAR STONE, NOMINAL SIZE DISTRIUTION ETWEEN 3/4-2 INCH [19-51 mm] MIN. VOID SPACE = 40% EGIN COMPACTION AFTER 24" [610 mm] OF MATERIAL OVER THE CHAMERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 12" [305 mm] MAX LIFTS TO A MIN. 95% STANDARD PROCTOR DENSITY. NO COMPACTION REQUIRED. MC-40 STORMWATER CHAMER SPECIFICATIONS PLATE COMPACT OR ROLL TO ACHIEVE A 95% STANDARD PROCTOR DENSITY CHAMERS SHALL E STORMTECH MC-40 OR APPROVED EQUAL. 2. CHAMERS SHALL E MADE FROM VIRGIN, IMPACT-MODIFIED POLYPROPYLENE COPOLYMERS. 3. CHAMER ROWS SHALL PROVIDE CONTINUOUS, UNOSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT PANELS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION. 4. ONCE LAYER C IS PLACEDANY SOIL/MATERIAL CAN E PLACED IN LAYER D UP TO THE FINISHED GRADE. MOST PMENT SUASE SOILS CAN E USED TO REPLACE THE MATERIALS REQUIREMENTS OF LAYER C OR D AT THE DESIGN ENGINEER'S DISCRETION. D IF REQUIRED 7. *TO OTTOM OF FLEXILE PMENT. FOR UNPD INSTALLATIONS, WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 30" (762 mm) 24" (610 mm) MIN* C 9" (229 mm) TYP 100" (2540 mm) 12" (305 mm) TYP 24" (610 mm) MIN* 7.0' (2.13 m) MAX 12" (305 mm) MIN " (24 mm) ONLY CHAMERS THAT ARE APPROVED Y THE ENGINEER WILL E ALLOWED. THE SHALL SUMIT (3 SETS) OF THE FOLLOWING TO THE ENGINEER FOR APPROVAL EFORE DELIVERING CHAMERS TO THE PROJECT SITE: 7.0' (2.13 m) MAX DEPTH OF STONE TO E DETERMINED Y DESIGN ENGINEER 9" (229 mm) MIN *TO OTTOM OF FLEXILE PMENT. FOR UNPD INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 30" (762 mm). CHAMERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F 2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMERS". " (24 mm) A PMENT DESIGN (PER ENGINEER'S DRAWINGS) THE STRUCTURAL DESIGN OF THE CHAMERS, THE STRUCTURAL ACKFILL AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD RIDGE DESIGN SPECIFICATIONS, SECTION ARE MET FOR: 1) LONG-DURATION DEAD LOADS AND 2) SHORT-DURATION LIVE LOADS, ASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. a. A STRUCTURAL EVALUATION Y A REGISTERED STRUCTURAL ENGINEER THAT DEMONSTRATES THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD RIDGE DESIGN SPECIFICATIONS, SECTION ARE MET. b. STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL CROSS SECTION IS ASED. 12" (305 mm) MIN ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONE 12" MIN THE SHALL PROVIDE THE CITY CERTIFIED REPORTS FROM A CERTIFIED LAORATORY VERIFYING THE AGGREGATE FOR THE WATER DETENTION LAYERS OF THE STORMWATER DETENTION FACILITY MEETS OR EXCEEDS 40% VOID SPACE. PMENT AND SUASE DESIGN (Y ENGINEER) MOST PMENT SUGRADE MATERIALS CAN E USED IN LIEU OF REQUIREMENTS FOR LAYERS C & D GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES, COMPACT IN 12" (305 mm) MAX LIFTS TO 95% STANDARD PROCTOR DENSITY. SEE THE TALE OF ACCEPTALE FILL MATERIALS. 1. PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO E CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: 2. AS AN ALTERNATE TO PROCTOR TESTING AND FIELD DENSITY MEASUREMENTS ON OPEN GRADED STONE, STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS CHAMERS SHALL E DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMERS" NOMINAL 3/4" - 2" (19 mm - 51 mm) CLEAN, CRUSHED, ANGULAR STONE (AASHTO M43 #3 & #4 STONE SIZES ALLOWED) 3, 4 3, 4 CHAMERS SHALL MEET ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMERS. 8. 9" (229 mm) MIN DESIGN ENGINEER IS RESPONSILE FOR ENSURING THE REQUIRED EARING CAPACITY OF SUGRADE SOILS MC-40 END CAP DEPTH OF STONE TO E DETERMINED Y DESIGN ENGINEER 9" (229 mm) MIN 12" (305 mm) TYP 100" (2540 mm) THE INSTALLED CHAMER SYSTEM SHALL PROVIDE THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD RIDGE DESIGN SPECIFICATIONS SECTION FOR EARTH AND LIVE LOADS, WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. THE INSTALLATION OF CHAMERS SHALL E IN ACCORDANCE WITH THE MANUFACTURER'S LATEST INSTALLATION INSTRUCTIONS. MC-40 TYP CROSS SECTION ACCEPTALE FILL MATERIALS: STORMTECH MC-40 CHAMER SYSTEMS MC-40 CHAMER " (24 mm) 59.4" (09 mm) 48.3" (1227 mm) INSTALLED ED PERIMETER 90.2" (2291 mm) 100" (2540 mm) V CREST UPPER JOINT CORRUGATION DUAL WALL PERFORATED HDPE UNDERDRAIN PIPE VENT HOLES V STIFFENING RI WE LOWER JOINT CORRUGATION C FOUNDATION STONE ENEATH CHAMERS STONE EDDING UNDER DRAINAGE PIPE C ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) 30.7" (781 mm) INSTALLED SECTION A-A MC-40 END CAP TO OUTLET CONTROL STRUCTURE CREST STIFFENING RI MC-40 END CAP FOOT NOMINAL CHAMER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) CHAMER STORAGE MINIMUM INSTALLED STORAGE* NOMINAL WEIGHT NOMINAL END CAP SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) END CAP STORAGE MINIMUM INSTALLED STORAGE* NOMINAL WEIGHT CATCH ASIN OR MANHOLE 32.8" (832 mm) 35.1" (891 mm) 52" (1321 mm) UILD ROW THIS DIRECTION FOUNDATION STONE ENEATH CHAMERS NUMER AND SIZE OF UNDERDRAINS PER ENGINEER'S DESIGN SECTION lbs [54.4 kg] 12" [305 mm] MIN. 90.2" x 59.4" x 30.7" [2291 mm x 09 mm x 781 mm] MC-40 END CAP 120 lbs [54.4 kg] 12" [305 mm] MIN. NOTE: MANIFOLD STU MUST E LAID HORIZONTAL FOR A PROPER FIT IN THE END CAP OPENING. OUTLET PIPE FOUNDATION STONE ENEATH CHAMERS PART NUMERS ENDING WITH "" ARE FOR STUS AT OTTOM OF END CAP. PART NUMERS ENDING WITH "T" ARE FOR STUS AT TOP OF END CAP. SUMP DEPTH TD Y DESIGN ENGINEER 24" (0 mm) HDPE ACCESS PIPE REQUIRED. USE FACTORY PRE-CORED END CAPS. 2 LAYERS OF ADS 3WTM WOVEN GEOTEXTILE ETWEEN FOUNDATION STONE AND CHAMERS. 10.3' (3.1 m) MIN. WIDE STRIPS MC-40 ISOLATOR ROW PROFILE STONE EDDING UNDER DRAINAGE PIPE ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) 100.0" x.0" x 48.3" [2540 mm x 24 mm x 1227 mm] *ASSUMES 9" (229 mm) STONE FOUNDATION, 9" (229 mm) ROW SPACING, 12" (305 mm) STONE AOVE, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY. PART # MC40REPE06T MC40REPE06 MC40REPE08T MC40REPE08 MC40REPE10T MC40REPE10 MC40REPE12T MC40REPE12 MC40REPET MC40REPE MC40REPE18T MC40REPE18 MC40REPE24T MC40REPE24 MC40REPE30 MC40REPE36 MC40REPE42 DUAL WALL PERFORATED HDPE UNDERDRAIN PIPE A COVER PIPE CONNECTION TO END CAP WITH ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) STU 6" [0 mm] 6" [0 mm] 8" [200 mm] 8" [200 mm] 10" [2 mm] 10" [2 mm] 12" [300 mm] 12" [300 mm] " [375 mm] " [375 mm] 18" [4 mm] 18" [4 mm] 24" [0 mm] 24" [0 mm] 30" [7 mm] 36" [900 mm] 42" [10 mm] 42.54" [1081 mm] 40." [1029 mm] 38.37" [975 mm] 35.69" [907 mm] 32.72" [831] 29.36" [746 mm] 23.05" [590 mm] C 0.86" [22 mm] 1.01" [26 mm] 1.13" [29 mm] 1.55" [39 mm] 1.70" [43 mm] 1.97" [ mm] 2.26" [57 mm] 2.95" [75 mm] 3.25" [83 mm] 3.55" [90 mm] A FILE "P:\00_6100\ _COTA RT\CIVIL\PLANS\PLAN SET DWG'S\STORMTECH DETAILS.DWG" : SD "5/30/ :16 AM" LAYOUT "LAYOUT (1)" : PRINTED "6/5/2017 8:57 AM" ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONE STONE EDDING UNDER DRAINAGE PIPE ADS 1 NON-WOVEN GEOTEXTILE (OR EQUAL) UNDERDRAIN TO MAINTAIN POSITIVE DRAINAGE TO MANHOLE SECTION C-C MC-40 UNDERDRAIN DETAIL C 1. CUSTOM INVERT LOCATIONS ON THE MC-40 END CAP CUT IN THE FIELD ARE NOT RECOMMENDED FOR PIPE SIZES GREATER THAN 10" (2 mm). 2. THE INVERT LOCATIONS IN COLUMN '' ARE THE HIGHEST POSSILE FOR THE PIPE SIZE. ADVANCED DRAINAGE SYSTEMS, INC. 70 INWOOD ROAD, SUITE 3 ROCKY HILL, CT 067 PHONE: FAX: NOTE: ALL DIMENSIONS ARE NOMINAL MC-40 TECHNICAL SPECIFICATIONS COTA RT: NORTHERN LIGHTS PARK AND RIDE LOT STORMTECH DETAILS 432 P (614) F (614)

MC-3500 & MC-4500 Design Manual StormTech Chamber Systems for Stormwater Management

MC-3500 & MC-4500 Design Manual StormTech Chamber Systems for Stormwater Management StormTech MC-3500 Chamber MC-3500 & MC-4500 Design Manual StormTech Chamber Systems for Stormwater Management THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS Call StormTech at 860.52.88 or 888.82.264

More information

StormTech Construction Guide

StormTech Construction Guide A division of StormTech solid end caps and pre-cored end caps StormTech chambers StormTech manifolds and fittings Acceptable fill materials per Table 1 Woven and non-woven geotextiles 80-7 DC REQUIRED

More information

StormTech Construction Guide

StormTech Construction Guide Stormtech MC-3500 Construction Guide 12/31/14 11:18 AM Page 1 M /M 00 35 C- A division of REQUIRED MATERIALS AND EQUIPMENT LIST 00 45 C- StormTech Construction Guide Detention Retention Water Quality Acceptable

More information

MC-3500 and MC-4500 Design Manual

MC-3500 and MC-4500 Design Manual MC-3500 / MC-4500 MC-3500 and MC-4500 Design Manual StormTech Chamber Systems for Stormwater Management Table of Contents 1.0 Product Information...2 2.0 Foundations for Chambers...8 3.0 Required Materials/Row

More information

StormTech Construction Guide

StormTech Construction Guide M /M 00 35 C- A division of REQUIRED MATERIALS AND EQUIPMENT LIST 00 45 C- StormTech Construction Guide Detention Retention Water Quality Acceptable fill materials per Table 1 Woven and non-woven geotextiles

More information

StormTech Construction Guide

StormTech Construction Guide REQUIRED MATERIALS AND EQUIPMENT LIST An 80-7 DC 0/ 74 C/S 10-3 SC StormTech Construction Guide company ~ Bc^a\CTRW b^[xs T]S RP_b P]S _at R^aTS T]S RP_b ~ Bc^a\CTRW RWP\QTab ~ Bc^a\CTRW \P]XU^[Sb P]S

More information

StormTech Construction Guide An company

StormTech Construction Guide An company SC-160LP StormTech Construction Guide An company REQUIRED MATERIALS AND EQUIPMENT LIST IMPORTANT NOTES: A. This installation guide provides minimum requirements for proper installation of chambers. Non-adherence

More information

PROJECT NAME: LOMBARDO CENTER STORMWATER RETENTION MODIFICATION PROJECT NUMBER: APPLICATION: MAJOR SITE PLAN #14376

PROJECT NAME: LOMBARDO CENTER STORMWATER RETENTION MODIFICATION PROJECT NUMBER: APPLICATION: MAJOR SITE PLAN #14376 AUGUST 20, 2014 PROJECT NAME: STORMWATER RETENTION MODIFICATION PROJECT NUMBER: 1999007247 APPLICATION: MAJOR SITE PLAN #14376 Met with staff 8/28/14, DRC on 9/8/14 1. DEPARTMENT: ENGDRN - STORMWATER REVIEW

More information

PRODUCT CATALOG MC-4500 SC-740 MC-3500 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS

PRODUCT CATALOG MC-4500 SC-740 MC-3500 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS PRODUCT CATALOG MC-4500 MC-3500 SC-740 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS STORMTECH SUBSURFACE STORMWATER MANAGEMENT TABLE OF CONTENTS Product Features and Benefits... 5 SC-160LP...6

More information

StormTech Product Catalogue

StormTech Product Catalogue StormTech Product Catalogue The Most Advanced Name in Drainage Systems StormTech Subsurface Stomwater Management Table of Contents Subsurface Stormwater Management...2 Specifications and Product Comparison...3

More information

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information.

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information. Product Catalogue Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information. StormTech Subsurface Stomwater Management Table of Contents

More information

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information.

Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information. Product Catalogue Not intended for design layouts; refer to the appropriate Design Manual for specific chamber design information. Subsurface Stomwater Management Specifications and Product Comparison

More information

Product Catalog. company SC-310 DC-780 SC-740 MC-3500 MC-4500

Product Catalog. company SC-310 DC-780 SC-740 MC-3500 MC-4500 An company SC-310 DC-780 SC-740 MC-3500 Product Catalog This catalog is not intended to provide requirements for design or installation of StormTech chambers. Refer to the appropriate StormTech Design

More information

Subsurface Sport Turf Applications

Subsurface Sport Turf Applications ADS Terms and Conditions of Sale are available on the ADS website, www.ads-pipe.com Advanced Drainage Systems, the ADS logo, and the Green Stripe, are registered trademarks of Advanced Drainage Systems,

More information

CULTEC STORMWATER CHAMBER SYSTEMS

CULTEC STORMWATER CHAMBER SYSTEMS DRAINAGE SOLUTIONS SINCE 1908 CULTEC STORMWATER CHAMBER SYSTEMS RETENTION / DETENTION / INFILTRATION ENVIRONMENTAL PROTECTION COST-EFFECTIVE LAND USE EASY TO INSTALL ARMTEC.COM CULTEC STORMWATER MANAGEMENT

More information

Installation Instructions. StormTech Chamber System for Stormwater Management

Installation Instructions. StormTech Chamber System for Stormwater Management SC-310/SC-740 Chambers Installation Instructions StormTech Chamber System for Stormwater Management Before You Begin REQUIRED MATERIALS AND EQUIPMENT LIST Acceptable nominal 3 4" 2" (19-51 mm) clean, crushed,

More information

Design Manual StormTech. Chamber Systems for Stormwater Management

Design Manual StormTech. Chamber Systems for Stormwater Management Design Manual StormTech Chamber Systems for Stormwater Management Table of Contents 1.0 Introduction...2 2.0 Product Information...3 3.0 Structural Capabilities...6 4.0 Foundation for Chambers...8 5.0

More information

PROJECT AT THE DENVER

PROJECT AT THE DENVER POROUS ASPHALT DEMONSTRATION PROJECT AT THE DENVER WASTEWATER BUILDING Ken A. MacKenzie, P.E. Manager, Master Planning Program Urban Drainage and Flood Control District 36 th Annual Rocky Mountain Asphalt

More information

StormTech DC-780 Chamber

StormTech DC-780 Chamber StormTech DC-780 Chamber DC-780 Chamber Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a costeffective method to save

More information

Installation Instructions StormTech Chamber System for Stormwater Management

Installation Instructions StormTech Chamber System for Stormwater Management Installation Instructions StormTech Chamber System for Stormwater Management Before You Begin REQUIRED MATERIALS AND EQUIPMENT LIST Acceptable 3 4" 2" (20-50 mm) clean, crushed, angular stone per Tables

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular

More information

EXISTING CONDITIONS. Town of Bedford, NH Sand Volleyball Courts Existing Conditions Sheet 2 of 5 GENERAL NOTES

EXISTING CONDITIONS. Town of Bedford, NH Sand Volleyball Courts Existing Conditions Sheet 2 of 5 GENERAL NOTES GENERAL NOTES 1. THE CONTRACTOR SHALL VERIFY AND DETERMINE THE LOCATION, SIZE AND ELEVATION OF ALL EXISTING UTILITIES SHOWN OR NOT SHOWN ON THESE PLANS PRIOR TO THE START OF ANY CONSTRUCTION. THE CONTRACTOR

More information

4.8. Subsurface Infiltration

4.8. Subsurface Infiltration 4.8. Subsurface Infiltration Subsurface infiltration systems are designed to provide temporary below grade storage infiltration of stormwater as it infiltrates into the ground. Dry wells, infiltration

More information

TOWN CENTER PARKING LOT AT

TOWN CENTER PARKING LOT AT PARCEL ID #: 26-20-0-5AR-0A00-006C AT TUSKAWILLA ROAD & TREE SWALLOW ROAD LEGAL DESCRIPTION C1.0 COVER C2.0 SWPPP PLAN C.0 SITE GRADING PLAN C4.0 GENERAL DETAIL L1.0 LANDSCAPE PLAN PLANS DESCRIPTION Franklin

More information

Design Manual. StormTech. Chamber Systems for Stormwater Management

Design Manual. StormTech. Chamber Systems for Stormwater Management SC-310/SC-740 Chambers Design Manual StormTech Chamber Systems for Stormwater Management Table of Contents 1.0 Introduction...2 2.0 Product Information...3 3.0 Structural Capabilities...6 4.0 Foundation

More information

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.0 Standard Specifications GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.1 Unless otherwise specifically set forth herein or in the Gwinnett County Standard Drawings, all of the materials, methods of the

More information

4.8. Subsurface Infiltration

4.8. Subsurface Infiltration 4.8. Subsurface Infiltration Subsurface infiltration systems are designed to provide temporary below grade storage infiltration of storm water as it infiltrates into the ground. Dry wells, infiltration

More information

SECTION TRENCHING

SECTION TRENCHING SECTION 31 23 17 TRENCHING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Excavating trenches for utilities and utility structures. 2. Bedding. 3. Backfilling and compacting to subgrade elevations.

More information

CONSTRUCTION PLANS FOR ENTERPRISE RENTAL CAR

CONSTRUCTION PLANS FOR ENTERPRISE RENTAL CAR CONSTRUCTION PLANS FOR VICINITY MAP (NOT TO SCALE) DEVELOPER/OWNER: CHRISTOPHER SLOVAN ENTERPRISE HOLDINGS, INC. 284 MALLORY STATION RD, SUITE 120 FRANKLIN, TN 37067 PH: 615-309-9621 DAVIDSON CO., TENNESSSEE

More information

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18) Page 1 of 8 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks

More information

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM SECTION 32 32 23 SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM PART 1: GENERAL 1.01 Scope Work includes furnishing all materials, labor, equipment, and supervision to install a Stonebridge segmental

More information

MagnumStone Specifications Gravity

MagnumStone Specifications Gravity MagnumStone Specifications Gravity SPECIFICATION FOR MAGNUMSTONE GRAVITY MECHANICALLY STABILIZED EARTH SYSTEM PART 1: GENERAL.01Description The work consists of supplying and installing all aspects of

More information

(a) This specification shall govern the implementation, performance, material and fabrication

(a) This specification shall govern the implementation, performance, material and fabrication CSI Specification Article I. GENERAL Section 1.01 Scope (a) This specification shall govern the implementation, performance, material and fabrication pertaining to the Sub surface Stormwater Storage System.

More information

SECTION STORM SEWER PIPE

SECTION STORM SEWER PIPE SECTION 4200 - STORM SEWER PIPE 4200.1 SCOPE: This section covers the requirements for all labor, equipment and materials for the installation of storm sewers pipes. Trenching guidelines are provided in

More information

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH DIVISION 32 EXTERIOR IMPROVEMENTS SECTION 32 32 23.13 SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH PART 1: GENERAL 1.01 Scope of Standards A. This standard provides general

More information

GEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT

GEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT PLACE TWO STANDARD CONNECTORS IN EACH UNIT AS SHOWN (VERTICAL ORIENTATION) INSERT TWO CONNECTORS PER HORIZONTALLY ORIENTED BLOCK; INSERT ONE CONNECTOR PER VERTICALLY ORIENTED BLOCK SHIM BETWEEN BLOCK COURSES

More information

Inlet Protection. Fe= (Depends on soil type)

Inlet Protection. Fe= (Depends on soil type) 3.4 DESIGN CRITERIA: KEY CONSIDERATIONS Evaluate drainage patterns to ensure inlet protection will not cause flooding of roadway, property or structures Never block entire inlet opening Size according

More information

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM Anchor Vertica SECTION 02832 CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Retaining wall system constructed of concrete segmental retaining wall units. B. Geosynthetic

More information

TOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. June 1984

TOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. June 1984 1 TOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION June 1984 1. DEFINITIONS APPROVAL, APPROVED, ACCEPTED OR WORDS OR TERMS OF SIMILAR MEANING: Written approval of the Highway Superintendent. BASE

More information

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Permeable Articulating

More information

TYPE "A" CATCH BASIN

TYPE A CATCH BASIN 27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,

More information

SECTION FILL AND BACKFILL

SECTION FILL AND BACKFILL PART 1 GENERAL 1.1 SECTION INCLUDES A. Filling, backfilling, and compacting for building volume below grade, footings, slabs-on-grade, paving, site structures, and utilities within the building. B. Backfilling

More information

and Green Infrastructure

and Green Infrastructure Key Benefits of StormTech Volumetric Reduction of Stormwater Through Infiltration Stormwater Quality Through Patented Isolator TM Row (TSS, TP and TPH removal) Reduction of Thermal Impacts Proven, Third

More information

PERMEABLE INTERLOCKING PAVERS

PERMEABLE INTERLOCKING PAVERS PERMEABLE INTERLOCKING PAVERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subgrade Preparation B. Placement of Storage Aggregate C. Placement of Filter Aggregate D. Placement of Bedding Course E. Placement

More information

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1 Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2

More information

Handling and Installation Instructions

Handling and Installation Instructions Handling and Installation Instructions SUPERTANK Water Reclamation Solutions, LLC Unloading and Handling NOTE: It is the responsibility of the installer to follow OSHA safety guidelines during the installation,

More information

A. This section includes the furnishing and installation of a foundation drainage system.

A. This section includes the furnishing and installation of a foundation drainage system. PAGE 334613-1 SECTION 334613 SPECIFIER: This Section is written to specify a drainage system for buildings, which normally includes a drain installed around the perimeter of a building or basement, but

More information

SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM

SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM MagnumStone Specifications Geogrid Reinforced SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM PART 1: GENERAL 1.01 Description The work consists of supplying

More information

BMP 6.4.4: Infiltration Trench

BMP 6.4.4: Infiltration Trench BMP 6.4.4: Infiltration Trench An Infiltration Trench is a leaky pipe in a stone filled trench with a level bottom. An Infiltration Trench may be used as part of a larger storm sewer system, such as a

More information

StormTech SC-310 Chamber (not to scale) Nominal Chamber Specifications

StormTech SC-310 Chamber (not to scale) Nominal Chamber Specifications StormTech SC-310 Chamber Designed to meet the most stringent industry performance standards for superior structural integrity while providing designers with a cost-effective method to save valuable land

More information

Appendix B.2. Construction Specifications for Infiltration Practices

Appendix B.2. Construction Specifications for Infiltration Practices Appendix B.2 Construction Specifications for Infiltration Practices B.2.A Infiltration Trench General Notes and Specifications An infiltration trench may not receive run-off until the entire contributing

More information

Contents. General Notes

Contents. General Notes DESIGN GUIDE 1 Contents 1.0 Introduction 2.0 Product Information 3.0 Manufacturing Standards 4.0 Structural Response 5.0 Foundation 6.0 System Materials 7.0 Connections 8.0 Pretreatment 9.0 Additional

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 321216 - ASPHALT PAVING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Contents. General Notes

Contents. General Notes DESIGN GUIDE 1 Contents 1.0 Introduction 2.0 Product Information 3.0 Manufacturing Standards 4.0 Structural Response 5.0 Foundation 6.0 System Materials 7.0 Connections 8.0 Pretreatment 9.0 Additional

More information

PROPOSED SEGMENTAL RETAINING WALLS ARGONAUT RETAIL VILLAGE - PHASE I PENSACOLA, FLORIDA

PROPOSED SEGMENTAL RETAINING WALLS ARGONAUT RETAIL VILLAGE - PHASE I PENSACOLA, FLORIDA CERTIFICATE AUTHORIZATION: 2 24 ANCHOR WALL ENGINEERING, LLC MATERIAL NOTES. Concrete Retaining Wall Units: "Anchor Diamond Pro Retaining Wall Units" as manufactured by Block USA under license from Anchor

More information

SECTION EARTHWORK

SECTION EARTHWORK SECTION 02200 EARTHWORK PART 1 - GENERAL 1.01 WORK INVOLVED A. Provide all labor, materials and equipment as required for all excavation, grading, providing borrow materials, hauling, placing and compacting

More information

Rethinking Water Management Systems

Rethinking Water Management Systems Rethinking Water Management Systems Table of Contents Introduction... 1 PIPE-R Reservoir System Installation Procedure... 2 Product Delivery and Assembly... 2 Site Layout and Excavation... 3 Preparation

More information

CHAPTER 2. Restricted Residential ½ Street** Design Speed 25 MPH 25 MPH 25 MPH 25 MPH 40 MPH 50 MPH 55 MPH

CHAPTER 2. Restricted Residential ½ Street** Design Speed 25 MPH 25 MPH 25 MPH 25 MPH 40 MPH 50 MPH 55 MPH CHAPTER 2 201 ROADS 201.1 General This section is to assist the designer in determining what is needed for the design of roads in public rights-of-way. For these standards, the terms used are: Restricted

More information

FLORIDA ENGINEERING AND ENVIRONMENTAL SERVICES, INC. ARMANDO CABRE, P.E. PROFESSIONAL ENGINEER NO

FLORIDA ENGINEERING AND ENVIRONMENTAL SERVICES, INC. ARMANDO CABRE, P.E. PROFESSIONAL ENGINEER NO ARMANDO CABRE, P.E. PROFESSIONAL ENGINEER NO. 66807 SAFETY OF THE TRAVELLING PUBLIC AND THE SAFETY OF HIS/HER PERSONNEL. OR HIS REPRESENTATIVE SHALL BE RESPONSIBLE FOR THE CONTROL AND SAFETY REGULATIONS

More information

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT SECTION 32 14 13 19 PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Permeable Articulating

More information

LANDSCAPE RETAINING WALLS

LANDSCAPE RETAINING WALLS SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9070 - Landscape Retaining Walls LANDSCAPE RETAINING WALLS PART - GENERAL.0 SECTION INCLUDES A. Modular Block Retaining Walls

More information

Specifying Asphalt Pavement the ODOT Way

Specifying Asphalt Pavement the ODOT Way Ohio Department of Transportation John R. Kasich, Governor Jerry Wray, Director Specifying Asphalt Pavement the ODOT Way David Miller, P.E. Office of Pavement Engineering Workshop on Design and Rehabilitation

More information

Dawson County Public Works 25 Justice Way, Suite 2232, Dawsonville, GA (706) x 42228

Dawson County Public Works 25 Justice Way, Suite 2232, Dawsonville, GA (706) x 42228 Dawson County Public Works 25 Justice Way, Suite 2232, Dawsonville, GA 30534 (706) 344-3500 x 42228 DAWSON COUNTY STORM WATER REVIEW CHECKLIST Project Name: Property Address: Engineer: Fax #/Email: Date:

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 02222 - EXCAVATION, BACKFILL, AND COMPACTION FOR UTILITIES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Excavating trenches for the installation of utilities and stormwater detention facilities. B.

More information

ENGINEERING REVIEW CHECKLIST City of Mount Clemens

ENGINEERING REVIEW CHECKLIST City of Mount Clemens (To be completed by the Developer s & Submitted with ing Plans) DATE: PROJECT NAME: Site Plan Approved: Date DESIGN ENGINEERING COMPANY: ing Company Contact Information: Name: Phone: Email: Owner Contact

More information

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM CornerStone Specifications Geogrid Reinforced SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL 1.01 Description The work consists of supplying and installing

More information

ODOT Design & Construction Requirements for MSE Walls

ODOT Design & Construction Requirements for MSE Walls ODOT Design & Construction Requirements for MSE Walls Peter Narsavage, P.E. Foundation Engineering Coordinator Ohio Department of Transportation Office of Structural Engineering 2006 Ohio Transportation

More information

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY INFORMATIONAL NOTES: READ THESE NOTES EFORE USING THESE S. USE THESE S AS A ASIS FOR THE PREPARATION OF STRUCTURE LAYOUTS AND CONTRACT DRAWINGS. ALL SUPPORTS LOCATED WITHIN THE CLEAR ZONE MUST E SHIELDED

More information

TOWN OF MOUNT PLEASANT WESTCHESTER COUNTY, NEW YORK

TOWN OF MOUNT PLEASANT WESTCHESTER COUNTY, NEW YORK TOWN OF MOUNT PLEASANT WESTCHESTER COUNTY, NEW YORK COST EVALUATION FOR ROLLING HILLS AREA WATER MAIN EXTENSION PROFESSIONAL CONSULTING, LLC. Octagon 10, Office Center 1719 Route 10, Suite 225 Parsippany,

More information

GRAVITY SEGMENTAL RETAINING WALL

GRAVITY SEGMENTAL RETAINING WALL [NOTE TO SPECIFICATION WRITER: This guide specification for the use of gravity segmental retaining walls (with no soil reinforcement) was developed based on the use of an aggregate or unreinforced concrete

More information

Fabrication and Installation Table of Contents

Fabrication and Installation Table of Contents Fabrication and Installation Table of Contents HDPE AQUASHIELD PRODUCTS 2 Fabrication and Installation 2 System Fabrication 3 Aqua-Swirl Installation 4 Step 1 Excavation and Bedding 4 Step 2 Pipe Connection

More information

SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS

SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS 12.1 The subdivider shall construct and install the improvements in accordance with the County's Standards for Construction Plans and Specifications

More information

5/25/2017. Lumpkin Detention Basin Houston, Texas By Brian Whitney, P.E., CFM Victor Rendon. Lumpkin Basin. Lumpkin Road Overall Description

5/25/2017. Lumpkin Detention Basin Houston, Texas By Brian Whitney, P.E., CFM Victor Rendon. Lumpkin Basin. Lumpkin Road Overall Description Lumpkin Detention Basin Houston, Texas By Brian Whitney, P.E., CFM Victor Rendon TEXAS FLOODPLAIN MANAGEMENT ASSOCIATION April 27, 2017 PROJECT LOCATION PROJECT VICINITY MAP Lumpkin Road Overall Description

More information

50.20 Drainage Structure Design

50.20 Drainage Structure Design 50.20 Drainage Structure Design All drainage structures, with the exception of bridges, culvert bridges and, in some cases, culverts, shall be designed for HS20-44 loading. Refer to Section 50.22 for design

More information

Appendix J: Storm Conveyance Design Parameters

Appendix J: Storm Conveyance Design Parameters Appendix J: Storm Conveyance Design Parameters Drain Commissioner 39 February 2005 STORM DRAINAGE DESIGN CRITERIA A. STORM SEWERS 1. The required discharge capacity shall be determined by the Rational

More information

HDPE PERFORATION GUIDE PERFORATIONS PER AASHTO M252/M294

HDPE PERFORATION GUIDE PERFORATIONS PER AASHTO M252/M294 PERFORATIONS GENERAL Lane s perforated pipe offerings follow the AASHTO classification system and conform to AASHTO requirements for size, spacing and placement of the perforations. It is not the intent

More information

E.P. CLARKE ELEMENTARY SCHOOL SITE IMPROVEMENTS

E.P. CLARKE ELEMENTARY SCHOOL SITE IMPROVEMENTS o:\projects\2016\ ep clarke elementary circulation\cad\_civil\ TL.dwg, 1, /5/2016 2:5:02 PM, mle, 1:1 NOTES: Sheet List Table SHT NO. DESCRIPTION COUNTY KEY OFFICIALS LOCAL UTILITIES CALL MISS DIG PROJECT

More information

SECTION FOUNDATION DRAINAGE

SECTION FOUNDATION DRAINAGE SECTION 33 41 13 SPEC WRITER NOTES: Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

SECTION 1 GENERAL NOTES

SECTION 1 GENERAL NOTES ISSUE DATE NOVEMBER 1st, 2011 SECTION 1 Page List Page Number Page Title COVER COVER GN-01 PAGE 1 GN-02 PAGE 2 GN-03 PAGE 3 GN-04 PAGE 4 GN-05 PAGE 5 GN-06 PAGE 6 GN-07 PAGE 7 : 1. (CCU) STANDARD SPECIFICATIONS

More information

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS SECTION 13100 MECHANICALLY STABILIZED EARTH RETAINING WALLS PART 1 -- GENERAL 1.01 THE REQUIREMENT A. Includes all labor, material, equipment, testing and submittals required to design and complete construction

More information

Rhode Island Stormwater Design and Installation Standards Manual

Rhode Island Stormwater Design and Installation Standards Manual Rhode Island Stormwater Design and Installation Standards Manual Public Workshop Infiltration (Including Permeable Paving) March 24, 2011 Infiltration Section 5.3: Appendix F.3 & H.1 Approved WQ BMPs Infiltration

More information

imm PACKAGE CONTENTS LIUUtilms

imm PACKAGE CONTENTS LIUUtilms STORMTECH ISOLATOR ROW Manufactured Treatment Device Submission Virginia BMP Clearinghouse June 30, 2104 PREPARED BY Chuck Lacey, Jr. PE Engineering Product Manager 301.875.8535 chuck.lacey@ads-pipe.com

More information

Installation Guidelines

Installation Guidelines 815 NE 172 nd Avenue Vancouver, WA 98684 877-694-0141 Installation Guidelines Installation steps include job planning, layout, excavating and preparing the soil subgrade, applying geotextiles (optional),

More information

Specification for Asphalt Paving for the Los Angeles Department of Water & Power DS Street Improvement

Specification for Asphalt Paving for the Los Angeles Department of Water & Power DS Street Improvement Specification for Asphalt Paving for the Los Angeles Department of Water & Power DS-144 - Street Improvement PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes specifications for providing asphaltic

More information

PUBLIC WORKS STANDARD DETAILS

PUBLIC WORKS STANDARD DETAILS PUBLIC WORKS STANDARD DETAILS SUBSTANTIAL EFFORT HAS BEEN MADE TO ENSURE THE INFORMATION CONTAINED IN THESE STANDARDS IS ACCURATE. HOWEVER, THE CITY OF BRADENTON BEACH CANNOT ACCEPT RESPONSIBILITY FOR

More information

Replace BID SCHEDULE with attached revised BID SCHEDULE.

Replace BID SCHEDULE with attached revised BID SCHEDULE. CONTRACT ADDENDUM Project: 9 st Ave SE & 4 th Street SE Sidewalk Improvements Project No: 00 Addendum No: Date: 0 September 0 Addendum: Replace BID SCHEDULE with attached revised BID SCHEDULE. Section

More information

The success in the mission of the Clinic is evident as the need now exceeds the current resources and physical facilities.

The success in the mission of the Clinic is evident as the need now exceeds the current resources and physical facilities. The Neighborhood Health Clinic Additions & Alterations City of Naples/ Design Review Board PROJECT DESCRIPTION The Neighborhood Health Clinic is located at 121 Goodlette-Frank Road North. The current building

More information

Michigan State University Construction Standards SEGMENTAL CONCRETE RETAINING WALLS PAGE SECTION SEGMENTAL CONCRETE RETAINING WALLS

Michigan State University Construction Standards SEGMENTAL CONCRETE RETAINING WALLS PAGE SECTION SEGMENTAL CONCRETE RETAINING WALLS PAGE 323223-1 SECTION 323223 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

Anchorplex retaining wall construction guide

Anchorplex retaining wall construction guide Anchorplex retaining wall construction guide Building Anchorplex Retaining Wall Systems Table of Contents and Introduction table of contents ow to Use This Guide......................... 2 About the Anchorplex

More information

SPECIAL SPECIFICATION 4653 Polypropylene Pipe

SPECIAL SPECIFICATION 4653 Polypropylene Pipe 2004 Specifications CSJ 2158-01-013, Etc. SPECIAL SPECIFICATION 4653 Polypropylene Pipe 1. Description. Furnish and install polypropylene pipe for constructing polypropylene pipe culverts or polypropylene

More information

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION UTILITY MANHOLES AND STRUCTURES SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition

More information

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR EASEMENT NOTES:. EASEMENT LIMIT SHOWN AS PROVIDED BY. TESC NOTES:. CONTRACTOR SHALL DEVELOP TEMPORARY EROSION AND SEDIMENT CONTROL PLAN AND PROVIDE ONSITE CERTIFIED EROSION AND SEDIMENT CONTROL LEAD (CESCL)

More information

Section 1I-3 - Bioswales

Section 1I-3 - Bioswales BIOSWALES (Numbering pending) These specifications compliment the bioswale design portion of the Iowa Stormwater Management Manual in Chapter 2, Section 2I-3. Sections of the following documents, as referenced

More information

2-16 EROSION, SEDIMENT & STORM WATER CONTROL REGULATIONS APPENDIX B1

2-16 EROSION, SEDIMENT & STORM WATER CONTROL REGULATIONS APPENDIX B1 2-16 EROSION, SEDIMENT & STORM WATER CONTROL REGULATIONS APPENDIX B1 There are three ways to accomplish urban soil erosion and sedimentation control: Allow erosion to take place and then control sediment

More information