Covering (Month/Year): January/2012 Submitted (date): 06/02/2012. Cotentin, Paris, France. van der Lelijstraat, Delft, the Netherlands
|
|
- Jacob Gregory
- 6 years ago
- Views:
Transcription
1 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): January/2012 Submitted (date): 06/02/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - Preparation of the deployment of several metering systems (beginning of February). The objective is to get data before refurbishment in order to facilitate the evaluation of its impact on energy performances and user comfort. - Monitoring system in 20 apartments: comfort and detailed electric consumption measurements. - Specific tests that will be repeated after refurbishment: infrared thermography (interior and exterior), blower-door test, acoustic test between floors and between apartments of a same floor. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: <01_2012_Paris_01> - Electric meter (without monitoring system) <01_2012_Paris_02> - Back side façade (target of TIR measurements)
2 01_2012_Paris_01 01_2012_Paris_02
3 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): February/2012 Submitted (date): 02/03/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - Several tests and monitoring deployment in one apartment (before refurbishment). - This month : focus on the blower door tests - 2 depressurized tests : to measure the airtightness as a function of the pressure difference value. Infrared thermography measurements are carried out simultaneously. - 1 pressurized test to make it possible to locate the air leakage pathways (with artificial smoke). It enables identifying locations where the thermal losses are potentially important. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: <02_2012_Paris_01> - Blower door assembly 02_2012_Paris_01
4 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): March/2012 Submitted (date): 02/04/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - Last month: focus on the blower door tests (before refurbishment). - This month : visual characterization of the performance of windows The infrared thermography emphasizes colder areas, which are supposed to be representative of thermal losses through the joints. The surface temperature values of the double-glazing cannot be interpreted as easily because of the specificity of its thermo-radiative properties. See <03_2012_Paris_01>. The observation of artificial smoke flows confirms the previous considerations by showing the air leakage pathways around areas that should be airtight (window joints). See <03_2012_Paris_02>. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: <03_2012_Paris_01> - Thermography of a window <03_2012_Paris_02> - Artificial smoke flows through a window
5 03_2012_Paris_01 03_2012_Paris_02
6 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): April/2012 Submitted (date): 09/05/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - Last month: visual characterization of the performance of windows - This month : sensor deployment for monitoring the before-retrofit situation Electric consumption: A clamp-on ammeter placed on the electric boards (see picture1) measures the real time consumption, for various electrical uses. Comfort : The indoor temperature and the hygrometric conditions are measured by a stand-alone sensor. A complete procedure is carried out for these measurements: observations planning (choice of the number of sensors, their type, their locations, the observation period, ), development and setting of the infrastructure (sensor, repeater, datalogger, computer, web application), calibration of the devices, data check system After applying this procedure the sensors are placed in such a way that they will be protected and will not bother the users (see picture 2). All the data collected will be subsequently analysed, for different time scales, in order to evaluate the consumption characteristics according to the indoor comfort conditions. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - <04_2012_Paris_01> Clamp-on ammeter - <04_2012_Paris_02> Stand-alone temperature/hygrometry sensor deployment
7 04_2012_Paris_01 04_2012_Paris_02
8 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): May/2012 Submitted (date): 07/06/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - Last month: sensor deployment for monitoring the before-retrofit situation - This month : Some contextual information about the refurbishment work planning (part 1) 1 building, 86 dwellings before renovation, 82 after Duration of the refurbishment work : 18 months This summer : call for tenders, result of the call, preparation of the work This autumn : Start of the refurbishment work 1 st task: Facades (10 months, start in autumn 2012). Refacing and insulation (20 cm EPS ETICS, smoothed rendering in the intermediate sections, stone cladding on metal framework at the ground level, zinc metal cladding at the top level). See the associated pictures to compare the external visual aspect of the facade before/after refurbishment. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - View of the facade (street side) before refurbishment <05_2012_Paris_01> - - Representation of the planned refurbished facade (street side) <05_2012_Paris_02>
9 05_2012_Paris_01 05_2012_Paris_02
10 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): June/2012 Submitted (date): 04/07/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month : Refurbishment work planning (part 2) Heating elements (10 months, start in winter 2013). New steel radiators in all the rooms except toilets. Adjustable thermostatic valve. Ambient thermostat. Ventilation (6 months, start in spring 2013). New controlled mechanical ventilation. Reuse of the existing vertical pipes. New pipes in suspended ceilings. New motors on the roof. Extraction vents in the kitchen, toilet, and bathroom. Relieving/planing of the doors. Roofs (3 months, start in spring 2013). Insulation and repairing of the sealing of the flat roofs. Wood slabs on accessible parts (exclusives terraces). Transformation of 10 balconies into bow-windows (increase in habitable surface area). Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - View of the planned roofs, with wood slabs on terraces and ventilation motors (source : APD) <06_2012_Paris_01> - - Example of the former ventilation management in the existing building (!) <06_2012_Paris_02> - Schematic drawing of the planned controlled mechanical ventilation system (source : presentation to the tenants) <06_2012_Paris_03>
11 06_2012_Paris_01 06_2012_Paris_02
12 06_2012_Paris_03
13 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): July/2012 Submitted (date): 24/08/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month : Refurbishment work planning (part 3) Heating production system (6 months, start in spring 2013): - replacement of the former boilers (see photo) by high efficiency new gas boilers - compliance of the fire resistance standards for basement-level boiler rooms Domestic Hot Water Production (5 months, start in spring 2013): - Heat recovery system on grey water (see photo). Works for the water from the dishwasher, washing machine, sink, basin, etc The system is based on a heat exchanger coupled to a small heat pump, and it is located in the boiler room. - Demolition of six cellars and construction of a storage facility for the hot-water tanks in the basement. - Refurbishment of the grey and waste water networks. Common areas (5 months, start in summer 2013). Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - View of the existing boiler room <07_2012_Paris_01> - - Block diagram of the heat recovery system for grey water (source: Biofluides) <07_2012_Paris_02>
14 07_2012_Paris_01 07_2012_Paris_02
15 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): August/2012 Submitted (date): 12/02/2013 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month: Preparation of the tender documents - As we are currently in a preparation phase, we propose in this monthly update a close-up on the measurements before retrofitting, the next 3 MU will detail some of these measurements and first results. Observations and measurements on several topics linked to energy efficiency and comfort. Some of these measurements correspond to continuous data from wireless sensors (figure), that s the case for temperature and humidity for example. Electric consumption (continuous) Hygrometric comfort (continuous over limited periods) Acoustic insulation (diagnostic) Air tightness (diagnostic) Thermal losses through thermal bridges (diagnostic) A measurement strategy was defined in order to ensure the comparison of the situations before and after retrofitting. Hence 2 measurements periods were chosen : 1 reference period between January 2012 and autumn 2012, 1 observation period from march 2013 (start of the retrofitting works). Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - Data collection from wireless sensors network <08_2012_Paris_01> -
16 08_2012_Paris_01
17 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): September/2012 Submitted (date): 18/02/2013 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month : Finalization of the tender documents - Close-up on the continuous measurements before retrofitting (electric and comfort). Based on International Performance Measurement and Verification Protocol (IPMVP) Expected precision: ± 0.35 C for air temperature, ±2.5% for relative humidity, ± 0,1 A RMS for electric intensity. 17 apartments are equipped (see schema for 1 example of deployment). Deployment of wireless routers in the common parts (see schema). 3 types of sensors for humidity/temperature conditions, different by their precision and context of use (see photo). 1 pair transmitter+clamp ammetter for the electric consumption (see photo). Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - Deployment of sensors in 2 apartments <09_2012_Paris_01> - - Deployment of wireless routers and other sensors <09_2012_Paris_02> - - Installation of a Humidity/temperature sensor <09_2012_Paris_03> - - Plugged-in clamp ammetter <09_2012_Paris_04> -
18 09_2012_Paris_01
19 09_2012_Paris_02
20 09_2012_Paris_03 09_2012_Paris_04
21 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): October/2012 Submitted (date): 05/03/2013 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month : Finalization of the tender documents, invitation to tender - Close-up on the acoustic diagnosis (before refurbishment) Measurements consistent with the NF EN ISO standard, assessment of the acoustic insulation (computation) consistent with the NF EN ISO standard, for buildings and construction components Material (see figures): Sonometer classe 1 type 2270 Brüel & Kjaer, microphones type 4189, acoustic source type 4224 Brüel & Kjaer, acoustic calibrator type 4231 class 1 (94 and 114 db at 1000 Hz), computation software BZ 5503 and QUALIFIER (Brüel & Kjaer) Results (see figure) : low acoustic insulation between 2 apartments, D nt,a = 44 db when it is recommended to be higher than 53 db, according to the french regulation context Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - Material for the acoustic test <10_2012_Paris_01> - - Positioning of the sensors <10_2012_Paris_02> - - Results of the test <10_2012_Paris_03> -
22 10_2012_Paris_01
23 10_2012_Paris_02
24 10_2012_Paris_03
25 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): November/2012 Submitted (date): 09/04/2013 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update (Ongoing works, planned works, setbacks or breakthroughs five sentences at the most. - This month: Selection of the companies for the realisation of the refurbishment works. - Close-up on the infrared thermography measurements (BEFORE RETROFIT) 2 types of measurements were carried out: 1) to observe the air tightness quality, 2) to observe the thermal bridges of the facades The measurements are made from the inside in depressurization conditions during the blower-door test. The colder parts of the pictures (see figure 2) indicate locations where the air tightness quality is lower (see figure 1). In figure 3 we observe air leaks from an entrance door from the common hallway, out of the depressurization period, hence the warmer temperature observed for the leaks here. It is important here to take into account the position of the camera (inside/outside) and the direction of the air flows (positive or negative pressures) in order to interpret correctly the measurements. The measurements are made from outside the building aiming at the facade. Warmer parts correspond to thermal bridges, mainly observable for intermediary floors, shear walls, and window frames (see figures 4 and 5). In order to interpret correctly the observations, it is important here to be careful about the diversity of materials included in the field of view, and more especially to the heterogeneity of radiative properties and radiative fluxes conditions. Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - Degraded seal, causing air leaks (put in evidence by the smoke generator) <11_2012_Paris_01> - - Observation of air leaks during the air tightness test
26 (depressurization) <11_2012_Paris_02> - - Observation of air leaks at the level of the entrance door <11_2012_Paris_03> - Observation of thermal bridges at the level of the intermediary floor and shear walls <10_2012_Paris_04> - Observation of thermal bridges at the level of window frames <11_2012_Paris_05> 11_2012_Paris_01
27 11_2012_Paris_02 11_2012_Paris_03
28 11_2012_Paris_04 11_2012_Paris_05
29 BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): December/2012 Submitted (date): 13/06/2013 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der Lelijstraat, Delft, the Netherlands Delivered by (name, company): Aurélien Henon, Nobatek News update This month: first meetings between ICF and the dedicated team from construction (Brezillon). About Beem Up: o Construction work is due for completion in the end of February 2014, according to engagement with Beem Up. o A site visit will happen by the end of July, in order to present the different technical choices in situation. About dwellings: o Site office and quarters will be installed in three flat, two type 4, at each end of the building and one type 3 in the middle. o Inventory of building will start during January. At the end, lists of works will be established and approved during a special meeting. o Show spaces must be chosen, especially the dwelling, where equipment, posters of project and materials samples, will be installed. About tenants: o A meeting has taken place to present the project to tenants. They have been notified about inventory of building. The work team has been introduced, and they have been given a short leaflet with an explanation of what is going to happened (planning, kind of works ). Pictures (at least two photos and/or videos are to be uploaded each month): Photo enclosed (jpg, min 300 dpi) Description: - <12_2012_Paris_01> - Meeting with the tenants <12_2012_Paris_02> - Presentation of the retrofitting program.
30 12_2012_Paris_01 12_2012_Paris_02
Covering (Month/Year): January/2014 Submitted (date): 05/03/2014. Cotentin, Paris, France. van der Lelijstraat, Delft, the Netherlands
BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): January/2014 Submitted (date): 05/03/2014 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France
More informationCovering (Month/Year): January/2012 Submitted (date): 06/02/2012. Cotentin, Paris, France
BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): January/2012 Submitted (date): 06/02/2012 Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France
More informationMethodology, Calculations and Results
1 BEEM-UP Building Energy Efficiency for Massive market Uptake: Methodology, Calculations and Results Ulrich Baum, LUWOGE consult GmbH, Holger Wallbaum, Chalmers University of Technology, Friedrich Reuter,
More informationBuilt examples and project certification. Zeno Bastian, Passive House Institute
Built examples and project certification Zeno Bastian, Passive House Institute Passive House Standard for Retrofits? Photo Passive House Institute Shape Graphic Passive House Institute Thermal Bridges
More informationCotentin, Paris, France. van der Lelijstraat, Delft, the Netherlands
BEEM Up WP2 Monthly Update template, material for the official website Covering (Month/Year): January/2014 Submitted (date): Construction site: Brogården, Alingsås, Sweden Cotentin, Paris, France van der
More informationRenovation of the Brogården area to Passive Houses
Renovation of the Brogården area to Passive Houses Ulla Janson, Tekn. lic, Energy and Building Design, Lund University; ulla.janson@ebd.lth.se http://www.ebd.lth.se NYCKELORD: passive houses, renovation,
More informationA Quality Assurance System for Improvement of Indoor Environment and Energy Use when Retrofitting Residential Houses
SQUARE A Quality Assurance System for Improvement of Indoor Environment and Energy Use when Retrofitting Residential Houses Pilot project Brogården in Alingsås, Sweden Kristina Mjörnell and Peter Kovacs
More informationKoniklecová 4, Brno-Nový Lískovec
Koniklecová 4, Brno-Nový Lískovec Project summary Energy concept: Renovation to low-energy / passive house standard Background for the renovation reasons: Intention for the renovation: Overall modernization
More informationWelcome to this continuing education seminar. This is the first of two parts of the High- Performance Building series.
Welcome to this continuing education seminar. This is the first of two parts of the High- Performance Building series. 1 3 6 7 8 An enclosure s basic function is to separate the outside from the inside.
More informationInvestigation and Retrofitting Proposal for a Panbo Type House in Sisimiut, Greenland
Downloaded from orbit.dtu.dk on: Dec 20, 2017 Investigation and Retrofitting Proposal for a Panbo Type House in Sisimiut, Greenland Qu, Jing; Vladyková, Petra; Villumsen, Arne Publication date: 2012 Link
More informationUpgrading To An A-Rated Home
Upgrading To An A-Rated Home Homeowner Guide HOW SEAI CAN HELP YOU AND YOUR HOME The Sustainable Energy Authority of Ireland (SEAI) is Ireland s national energy authority, investing in and delivering appropriate,
More informationBPE Case study of Pippin Close and Barnlea Close
BPE Case study of Pippin Close and Barnlea Close Building Performance Evaluation conference 14 th July 2015 Woking Professor Rajat Gupta and Mariam Kapsali Low Carbon Building Group, Oxford Institute for
More informationHomesol Passive House Design Process
Homesol Passive House Design Process Passive Houses are residential, commercial and institutional buildings in which a comfortable temperature can be achieved year round with a 75% 85% reduction in energy
More informationA, B, C, D VENTILATION SYSTEMS: COMPARISON
A, B, C, D VENTILATION SYSTEMS: COMPARISON ATIC-ULg Ventilation day 19/11/2015 Samuel Gendebien University of Liège Table of content Objectives of the presentation Introduction - Key figures Definitions
More informationComparison of measured and predicted sound insulation for a thermal retrofitted building
Comparison of measured and predicted sound insulation for a thermal retrofitted building C. Guigou-Carter, R. Foret, R. Wetta,P. Ducruet, M. Villot CSTB Inter-Noise 2010 Lisbon, Portugal PAGE 1 Introduction
More informationAdaption of the passive house concept in northern Sweden - a case study of performance
Passivhus Norden 2013 Adaption of the passive house concept in northern Sweden - a case study of performance Itai Danielski, The Department of Ecotechnology and Sustainable Building Engineering, Mid Sweden
More informationQuality specifications for my home
Quality specifications for my home by 7 Benefits of a dospuntos home 2 Quality specifications Casa Banderas 01 02 Outside: Before you go in: Façades Your home will have a ceramic brick façade finished
More informationThe BIG Energy Upgrade Energy Innovation for Retrofitting Deprived Community Housing in the UK
The BIG Energy Upgrade Energy Innovation for Retrofitting Deprived Community Housing in the UK Dr. Hasim Altan Lecturer in Sustainable Environmental Design Director of BEAU Research Centre, School of Architecture
More information2000 Antwerp, terraced house
2000 Antwerp, terraced house 1. INTRODUCTION PROJECT SUMMARY - First phase energy renovation: 1999 - Second phase energy renovation: 2007 SPECIAL FEATURES - Two phased energy renovation - The owners stayed
More informationSOLAR PHOTOVOLTAIC ENERGY
SOLAR PHOTOVOLTAIC ENERGY THE PHOTOVOLTAIC TECHNOLOGY PRODUCES CLEAN ELECTRICITY FROM SOLAR ENERGY 126 m 2 of photovoltaic modules are installed that generate about 12,000 kwh electricity per year, equivalent
More informationCOMPARISON OF MEASURED AND PREDICTED SOUND INSULATION FOR A THERMAL RETROFITTED BUILDING
Invited Paper COMPARISON OF MEASURED AND PREDICTED SOUND INSULATION FOR A THERMAL RETROFITTED BUILDING C. Guigou-Carter 1, R. Foret 2, R. Wetta 1, P. Ducruet 1, M. Villot 1 Affiliation: { 1 CSTB, 24 Rue
More informationSocial Housing. York Street, Dublin SEÁN HARRINGTON ARCHITECTS
Social Housing. York Street, Dublin SEÁN HARRINGTON ARCHITECTS Dublin City Centre York Street N Critical Design Issues; 1. Social Inclusion 2. Energy 3. Water 4. Biodiversity 5. Building Materials 6.
More informationApartment building Sodastraße 40 in Ludwigshafen, DE
Apartment building Sodastraße 40 in Ludwigshafen, DE PROJECT SUMMARY Renovation of an apartment building with exposed brickwork, built in 1892. 78% reduction of annual heat energy demand with interior
More informationINFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS
INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit
More informationRow House Henz-Noirfalise in Eupen, Belgium
Row House Henz-Noirfalise in Eupen, Belgium PROJECT SUMMARY Transforming a 19th century row house into a Passive House SPECIAL FEATURES Inside insulation of the facade ARCHITECT Fhw architectes scprl www.fhw.be
More informationCatalogue of Learning Targets. Certified PHPP Expert
Catalogue of Learning Targets Certified Expert Draft - valid as of 01.December 2018 The Passive House Institute (PHI) has extended the existing training and certification system for designers and tradespeople
More information2014 British Columbia Building Code Changes
2014 British Columbia Building Code Changes A City of Prince George interpretation of the 2014 Building Code Changes for 9.32 & 9.36 The following changes reflect the most notable revisions and staff interpretations.
More informationReliance House Investors Report. IR11 September 2018
Reliance House Investors Report IR11 September 2018 Extension & Conversion of Reliance House to Create 139 Luxury Apartments The 3 storey extension, refurbishment, adaptation and the sub-division works
More informationVia Parque Alicante BUILDING SPECIFICATIONS
WE BUILD YOUR HOUSE, SO YOU CAN MAKE IT A HOME Via Parque Alicante BUILDING SPECIFICATIONS f\ acciona Inmobiliaria First impressions do count 01. FAÇADE Facing brick façade to feature two colours, depending
More informationLocal project in Dublin - IRELAND
Local project in Dublin - IRELAND Tyrrelstown Housing is a new development of Social Rented, Shared Equity and Affordable Purchase family dwellings by National Association of Building Co-operatives (NABCo)
More informationDienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
More informationAPISSEQ Sisimiut Greenland 1st winter survey 2011
Downloaded from orbit.dtu.dk on: Dec 20, 2017 APISSEQ Sisimiut Greenland 1st winter survey 2011 Kotol, Martin Publication date: 2011 Document Version Publisher's PDF, also known as Version of record Link
More informationPassive House Project documentation
Passive House Project documentation Architecture: CadViz: Building physics: ehaus, Cyril Vibert Building Services: ehaus, Cyril Vibert Craftsperson: ehaus A compact two level family home with 4 bedrooms
More informationMethods for Investigation of Technical Status Before Renovation and Evaluation of Renovation Measures for the Building Envelope
Methods for Investigation of Technical Status Before Renovation and Evaluation of Renovation Measures for the Building Envelope Kristina Mjörnell and Thorbjörn Gustavsson, SP, Angela Sasic, Chalmers University
More informationWelcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series.
Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series. 1 3 6 7 8 The primary reasons to build airtight buildings are to avoid drafts
More informationBuilding & Ductwork Airtightness Standards
Building & Ductwork Airtightness Standards Version 1.02, August 2013 Standard Reference Technical Body Title ICS (International Classification for Standards) Scope Door and Windows EN 12207:1999 Windows
More informationEnergy-Efficient Passive House using thermal mass to achieve high thermal comfort
Energy-Efficient Passive House using thermal mass to achieve high thermal comfort Loa Andersson Managing Director RLI Byggdata AB rli@termodeck.com Alexander Engström Technical Director RLI Byggdata AB
More information14.8 kwh/(m²a) Project Documentation. 1 Abstract. R-951 Residence: Three Family Passive House Building. 1.1 Data of building. Year of construction
Project Documentation 1 Abstract R-951 Residence: Three Family Passive House Building 1.1 Data of building Year of construction U-value external wall/ U-Wert Außenwand 2013 0.112 W/(m²K) Space heating
More informationDemonstration building
FACTSHEET Demonstration building Housing complex - Via Palermo Note: the content of this document will be subject to changes until the end of the Sinfonia project (May 2020) Version 10/10/2017 PROFILE
More informationCan you Believe Energy Savings Forecasts
Can you Believe Energy Savings Forecasts By: Tony Woods Introduction Yes, says TonyWood. Especially when your project includes an upgrade to the building envelope. The relationship between high performance
More informationPassive House Object Documentation
Passive House Object Documentation 3 stores, 9 units multifamily building in Lonato, Brescia, Italy Project team Architecture: Arch. Angiolino Imperadori Structures and tech. services: Ing. Giovanni Ziletti
More informationPractical experiences with buildings in Arctic Greenland
Practical experiences with buildings in Arctic Greenland Two case studies from Sisimiut, Greenland Petra Vladykova Technical University of Denmark and Swegon AB petra.vladykova@swegon.se Swegon Air Academy,
More informationEnergy Efficiency Requirements 9.36
The following information has been obtained from the HPO Illustrated Guide, Energy Efficiency Requirements for Houses in British Columbia, BCBC 9.36 & 9.32, Building Officials Association of British Columbia
More informationAn Adaptable Façade Concept for Sustainable Office Refurbishment
Session B-4: Developments of Activation Technologies An Adaptable Façade Concept for Sustainable Office Refurbishment Thiemo EBBERT, Ph. D. 1 Ulrich KNAACK² 1 2 Delft University of Technology, Faculty
More informationD3.9_Overall Refurbishment Plan DRAFT CS03. Hotel Restaurant Valcanover
D3.9_Overall Refurbishment Plan DRAFT CS03 Hotel Restaurant Valcanover INTELLIGENT ENERGY EUROPE II Energy efficiency and renewable energy in buildings IEE/12/070 EuroPHit [Improving the energy performance
More informationROW - Albertslund, DK
PROJECT SUMMARY Renovation and additional insulation of roof, facades and floor. New bay windows, bathrooms, kitchens and interior surfaces. Designed per Danish low energy class 2 (63,3 kwh/m² a for a
More informationWater control Vapor control and drying Room for growth
How do we decide whether to insulate to inside or the outside? How to install windows in a DER wall (let me count the ways ) What s the best approach for historic buildings? How to deal with basement walls
More informationThe Alcalá Residential Development combines the peace and quiet of a residential area with the convenience of living in the city.
Your new life starts here In Parque Almunia, one of the areas in Granada with the most growth, Inmobiliaria Osuna is building a development for you that is unique in its specifications, amenities, location
More informationSupplementary Standard SB-12. Energy Efficiency For Housing
OBC Excerpt: SB 12 Ministry of Municipal Affairs and Housing Building and Development Branch 2006 Building Code - Supplementary Standards Supplementary Standard SB-12 Energy Efficiency For Housing November
More informationLaunching of the Probis Project, Procurement of building innovative solutions.
#1 Procurement of building innovative solutions newsletter # 1 November 2014 Editorial Launching of the Probis Project, Procurement of building innovative solutions. More than 20 European experts have
More informationFuture tree planting on the two acre lot will offset remaining lifetime carbon emissions.
Luxury Net-Zero Home by Rockwood Custom Homes 47 Grandview Place, Calgary AB T3Z A8 by Grant Bremner A Net-Zero Emissions (NZE) home is carbon neutral where carbon credits fully offset emissions. An NZE
More informationPASSIVE HOUSE OBJECT DOCUMENTATION
PASSIVE HOUSE OBJECT DOCUMENTATION Rua do Mar House B, single family house, Ílhavo Portugal (Passive House project database: ID 2403) 2.1 PROJECT OVERVIEW Project designer: João Marcelino, Homegrid (www.homegrid.pt)
More informationZEMedS: Implementation
ZEMedS: Implementation Implementation Case: Pere Borrell, Puigcerdà, Catalonia (Spain) General data 3 Name of the School Type of school Pere Borrell High School High School Number of students Owner 487
More information71 kwh/(m²a) Project Documentation. 1 Abstract. Single family house in Bellbrae, Victoria, Australia. 1.1 Data of building. Year of construction
Project Documentation 1 Abstract Single family house in Bellbrae, Victoria, Australia 1.1 Data of building Year of construction U-value external wall 2015 Space heating 0.220 W/(m²K) 16 kwh/(m²a) U-value
More information2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012
2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,
More informationEfficient and smart climate shell. refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT
6 Efficient and smart climate shell FACTSHEET refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT Fig. 1: Image: www.idae.es LOW ENERGY DISTRICT
More informationENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE
Bulletin of the Transilvania University of Braşov Vol. 3 (52) - 2010 Series I: Engineering Sciences ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE M. MOLDOVAN 1 I. VIŞA 1 A. DUŢĂ 1 Abstract: Into
More informationAPPENDIX 3C DOMINION HOTEL SPECIFICATIONS
APPENDIX 3C DOMINION HOTEL SPECIFICATIONS 1. GENERAL 1.1 Refer to Section 2.1 of Schedule 3 [Design and Construction Specifications] regarding compliance with Schedule 3 and this Building Specification.
More informationProject name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles
http://lowenergybuildings.org.uk Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles Project Description Projected build start date
More information5 social row houses (Wachtebeke)
5 social row houses (Wachtebeke) 1. OVERVIEW PROJECT SUMMARY - Year of construction: 1971 - Renovation: 2012 - Building typology: Social housing SPECIAL FEATURE - Demolition of facade brick & adding 30
More informationDocumentation of pilot project Apartment building in Vaives street 4, Cesis city
Documentation of pilot project Apartment building in Vaives street 4, Cesis city Market Transformation Towards Nearly Zero Energy Buildings Through Widespread Use of Integrated Energy Design (MaTrID):
More informationMethodology for diagnosis of real condition of a listed building envelope for its refurbishment
PLEA2013-29th Conference, Sustainable Architecture for a Renewable Future, Munich, Germany 10-12 September 2013 Methodology for diagnosis of real condition of a listed building envelope for its refurbishment
More informationEnerPHit. Criteria for Residential-Use Refurbished Buildings
Passive House Institute Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de EnerPHit Certification as Quality-Approved Energy Retrofit with Passive House Components Criteria for Residential-Use
More informationWP5.5: Product concepts for high efficiency step by step retrofits
WP5.5: Product concepts for high efficiency step by step retrofits Final presentation Product development 1. Aim of Product development 2. Summary of demand - what exists and what is needed 3. Meetings
More informationAM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y
Nearly zero-energy building and components of the DIRECTIVE on energy performance of buildings 2010/31/EU Albin Zsebik, PhD, CEM Improving university curricula in the areas of a) energy efficiency in the
More informationPassiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings
Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings Passive Houses
More informationENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING
ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING Brittany Hanam 1, Lorne Ricketts 2, Andrew Pape-Salmon 3 ABSTRACT The National Institute of Building Sciences estimates that over 70% of the
More informationIFORE Retrofitting Works Outreau. Pre-retrofit Description
IFORE Retrofitting Works Outreau Program : 2952 Address : Georges Braque Street Building year : 1979 Pre-retrofit Description 10 cm width concrete paving Floor Gable end walls Front wall Exterior render
More informationExtra 6. Sustainability. The Sigma Home. December 2009
6 December 2009 The Sigma Home As the house-building industry makes progress in the transition towards the zero carbon homes of the future, some useful postoccupancy research has recently been published
More informationThe Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies
COM Elithis Tower in Dijon, France Elithis Tower, located in Dijon, France, provides strong evidence that net zero energy office buildings are achievable in near future. The building, which was designed
More informationPilot project: DUTH Student residences, Komotini, Greece. Detailed technical and financial action plans for each individual building block
MED Programme Priority-Objective 2-2: Promotion and renewable energy and improvement of energy efficiency Contract n. IS-MED10-029 Pilot project: DUTH Student residences, Komotini, Greece Detailed technical
More information2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012
2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012 Building energy codes and standards have an important impact on the multifamily industry. Today, apartment properties face new
More informationBuilding Performance Evaluation
BUILDING PERFORMANCE EVALUATION CASE STUDY ONE BRIGHTON One Planet Living Zero carbon (renewable heat, on and off-site renewable electricity) Mechanical ventilation with heat recovery, communal heating,
More informationRENOVATION UPGRADE REPORT
File Number: 79CGD00001 NRCan.gc.ca/myenerguide RENOVATION UPGRADE REPORT 214-620 View St Victoria, BC V8W 1J6 Potential rating Current rating 59 176 GJ/year GJ/year 65GJ/year Uses most energy E 0 GJ/year
More informationBuilding Energy Efficiency for Massive Market Uptake
Building Energy Efficiency for Massive Market Uptake A message from the project coordinator BEEM-UP aims to demonstrate the economic, technical and social feasibility of retrofitting to drastically reduce
More informationD 4.1 Implementation of models of coordination DYNACITÉ (France)
D 4.1 Implementation of models of coordination DYNACITÉ (France) PART I PILOT PROJECT TECHNICAL DESCRIPTION 1. Description of the pilot building The pilot building is situated at Nurieux Volognat (21,
More informationConcept 9: Exterior refurbishment of wooden frame walls with flex system board insulation
Concept 9: Exterior refurbishment of wooden frame walls with flex system board insulation Cross section figures of the existing wall / the refurbishment concept Market potential and reasoning Application
More informationGreen Building Roundtable: Current Construction Techniques and Deep Energy Retro-Fits January 8, 2010
Green Building Roundtable: Current Construction Techniques and Deep Energy Retro-Fits January 8, 2010 Roundtable Discussion Framework: 8:00 AM Welcome and Introductions 8:15 AM Efficient Foundation Construction
More information2010 National Building Code Adoption and Associated Process Changes
Building Inspection City of Moncton 655 Main Street Moncton, NB E1C 1E8 Phone: (506) 856-4375 Fax: (506) 856-4348 Bulletin No. 14 From: Randy Richard Date: February 9, 2015 Subject: 2010 National Building
More informationCOMMISSIONING, OPERATION AND MAINTENANCE
CHAPTER 9 COMMISSIONING, OPERATION AND MAINTENANCE THIS CHAPTER IS PROVIDED FOR REFERENCE ONLY. IT IS NOT ADOPTED AS A REQUIREMENT OF THE CODE. SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter
More informationCONCEPT. Rowner Research Project Phase One. March /5
CONCEPT Rowner Research Project Phase One March 2014 1/5 The Rowner research project was undertaken in Gosport and spanned from 2009-2013. The Project was funded by the Technology Strategy Board (TSB)
More informationBUILDING SPECIFICATIONS
BUILDING SPECIFICATIONS FOUNDATION AND STRUCTURE Foundations using reinforced concrete slabs, according to the data of the geotechnical study, complying with building standard CTE-DB-SE-C. Concrete walls
More informationWP6. ENERGY REFURBISHMENT BUILDINGS
WP6. ENERGY REFURBISHMENT BUILDINGS D.6.1.- EXTRACT FROM THE MAIN TECHNICAL CHARACTERISTICS OF THE PRELIMINARY PROJECTS. ENERGY CONSIDERATIONS. OFICINA EFIDISTRICT TXANTREA. Calle Huarte, nº 32, bajo.
More informationSalford Energy House An overview.
Salford Energy House An overview www.salford.ac.uk/energy 2 Salford Energy House Salford Energy House 3 The Salford Energy House testing facility Background A unique testing asset, the Energy House is
More informationcurrently referenced throughout the
STANDARD WORK SPECIFICATIONS: HOME ENERGY UPGRADES FOR EXISTING MANUFACTURED HOMES Page 1 of 4 General Comments 1. The work specifications for manufactured housing should be the same as the specifications
More informationCompliance to the IgCC. September 29, 2011
Bringing Outcome-Based Compliance to the IgCC September 29, 2011 Outcome-Based Codes: Any code requirement or code enforcement mechanism based on actual outcomes in buildings after they have been occupied.
More informationPROGRAM COST MODEL. for. PEER Tall Buildings Study Concrete Structural Option Los Angeles, California
PROGRAM COST MODEL for PEER Tall Buildings Study Concrete Structural Option Los Angeles, California March 8, 2010 PEER Tall Buildings Study Concrete Structural Option March 8, 2010 CONTENTS Page Nos. Overall
More informationMetro Community College January 27-28, Building Science Corporation
2007 2008 What Do We Want To Do? Low-Energy Buildings Intro and Retrofits John Straube www.buildingscience.com Safe Healthy Comfortable Durable Affordable Environmentally Responsible Consulting.com 2 2
More informationCity of Toronto Tower Renewal Program
Photo by Jesse Colin Jackson City of Toronto Tower Renewal Program CAC Presentation October 6, 2016 1 Tower Renewal A program to drive broad environmental, social, economic, and cultural change by improving
More informationOpportunities to decarbonize the building sector through renewables
Workshop - Mitigation in the building sector Opportunities to decarbonize the building sector through renewables Bonn, Germany 31 July 2017 Strong growth in urban energy use More than half of all people
More informationSemi-detached house in De Pinte, Belgium
PROJECT SUMMARY Retrofit of a semi-detached house from the 50 s towards passive house standard. SPECIAL FEATURES Passive house standard Ecological design ARCHITECT Alexis Versele Architecten vennootschap
More informationControlling Moisture.
. Controlling Against Moisture Damage For Wall Sheathing...3 Sweaty Vents...4 Controlling Condensation In The Home...4 Controlling Against Moisture Damage For Wall Sheathing Moisture can cause many structural
More informationElectrical and Mechanical Engineering Services. Survey Report. Sussex Lodge and Stanhope Terrace London W2 OSCAR FABER
Electrical and Mechanical Engineering Services Survey Report Sussex Lodge and Stanhope Terrace London W2 OSCAR FABER October 2000 Contents 1 Introduction 1 1.1 The Purpose of the Report 1 1.2 Building
More informationZEM ds : Case studies
ZEMedS: Case studies Case study: Salamanque Group school, Montpellier, France The sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion
More informationIECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST
IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST ENVELOPE REQUIREMENTS Project: Date: Instructions RECOMMENDED: List performance values, note exceptions that were applied, or provide other
More informationJOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager
JOTUN Cool Shades Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings ai³ Werner Jager Exclusion of warranty: All tables, graphical charts and results presented within
More informationEnergy Performance Certificate
Energy Performance Certificate 64c, Clarkegrove Road Dwelling type: Mid-floor flat SHEFFIELD Date of assessment: 07 April 010 S10 NJ Date of certificate: 07 April 010 Reference number: 0077-843-6545-9500-831
More information(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 43, Langdon Street Dwelling type: Mid-terrace house SHEFFIELD Date of assessment: 18 March 2010 S11 8BH Date of certificate: 20 March 2010 Reference number: 0074-2848-6077-9090-2205
More informationINTEGRATED APPROACH TO ENERGY EFFICIENCY IN CULTURAL HERITAGE BUILDINGS
INTEGRATED APPROACH TO ENERGY EFFICIENCY IN CULTURAL HERITAGE BUILDINGS Margareta Zidar, Željka Hrs Borković Energy institute Hrvoje Požar e mail: mzidar@eihp.hr zhrs@eihp.hr ABSTRACT According to Croatian
More information