Condition Monitoring Services for Today s Demands

Size: px
Start display at page:

Download "Condition Monitoring Services for Today s Demands"

Transcription

1 Total Laboratory Solutions Condition Monitoring Services for Today s Demands ISO 91: 2 Certified ISO 1725: 25 Accredited trico corporation 1235 hickory street pewaukee, wi trico laboratory 9555 rockside road cleveland, oh

2 overview Unscheduled downtime is an organization s number one enemy. In an environment where equipment is expected to run 24 hours-a-day, 7 days-a-week under extreme operating conditions, equipment failure can quickly bring production to a halt. This can turn your normal workday run into an excruciating marathon. What if you could prevent downtime? Imagine being able to see exactly what s happening inside your equipment. You could prevent failure, enhance machine performance and gain a competitive edge. That s where Trico can help. Trico s Total Laboratory Solutions can help you see the condition of your oil and equipment without shutting you down. Trico s analysts can detect failures in progress and point you straight to the root cause, providing you with sufficient lead time to schedule corrective maintenance before catastrophic failure, with minimal disruption of your operations. When it comes to your machinery s life don t guess. The Cost of Guessing: Unplanned downtime Poor utilization of personnel Costly repairs Increased part replacement costs Increased maintenance costs Decreased equipment reliability Unnecessary oil changes Increased overtime The Value of trico s total laboratory solutions: Detailed result interpretation and recommendations by experienced analysts Service and parts support to assist in Lubrication Program implementation Downtime can be organized and planned rather than reactive Troubleshoot problems with more precision, less guesswork Experienced laboratory and analytical staff ensuring high quality and timely information State-of-the-art laboratory instrumentation utilizing applicable ASTM and ISO standards for producing reliable test data Quick turnaround reporting capabilities that are sent by or can be accessed from password protected website High-quality supplies and hardware for consistent, repeatable sample collection Professional customer support making individual service programs efficient and easy to use

3 oil analysis Used Oil Analysis Our used oil analysis provides a variety of physical and chemical tests to assess lubricant condition and its ability to perform, as required by the machine s application. We provide a variety of test packages to determine contamination levels and the health of your lubricant so you can take the necessary actions when needed. Tests offered: Viscosity Elemental Analysis Total Acid Number and Base Number Crackle Test Water by Karl Fischer Particle Count Fourier Transform Infrared (FTIR) Soot Concentrations Fuel Contamination Many More Fuel Testing Fuel quality is essential to proper and cost-efficient engine operation. Long-term storage and transfer of fuels can result in water, sludge, or organic contamination. Chemical and physical properties may also deteriorate. Fuel contamination and degradation are often the cause of diesel engine failures. Trico s fuel analysis service provides information to help you maintain the highest engine performance. These tests allow you to screen out poor quality stocks and ensure that your fuel meets regional and seasonal operating requirements. Tests offered: Water and Sediment Distillation Cloud and Pour Point API Gravity Flash Point Thermal Stability Biological Growth Many more Coolant Testing Controlling equipment temperature is necessary for optimum operating performance. Trico s coolant analysis alerts you to coolant breakdowns that may contribute to engine failures. Our trained technicians measure your coolant s freezing point, boiling point, and contamination levels in order to help you make seasonal change-out decisions. Oil Analysis benefits: Evaluate the chemical contamination of the oil Determine the usability of the oil Determine the dissolved elements and concentration of additives Estimate the usable life of the oil Identify trends that could contribute to harmful performance Determine optimum oil change intervals

4 wear debris analysis (ferrography) Trico s Wear Debris Analysis provides accurate insight into the condition of a machine s lubricated components by examining wear particles and contaminants suspended in the fluid including grease and water-based fluids. These particles can reveal abnormal wear, components involved, and the cause. Our predictive analysis will identify wear-related conditions at an early stage, preventing catastrophic equipment failure. Trico reduces repair costs by diagnosing maintenance requirements before extensive equipment damage and unscheduled shutdown occur. Trico provides two types of wear debris analysis: Direct Reading Ferrography Direct Reading Ferrography magnetically separates wear particles and optically measures the quantity of large and small particles present in the oil sample. Results from direct reading ferrography indicate the rate, intensity and severity of wear. With these measurements, machine wear baselines can be established and trends in wear conditions can be monitored. If there is a significant increase in the wear trend levels, a detailed analytical ferrography should be performed. Analytical Ferrography When Direct Reading Ferrographs and/or other analysis indicate abnormal wear, Trico s Analytical Ferrography can further pinpoint its source and the specific type of wear. Our skilled analysts will extract, classify and visually analyze wear particles and solid contaminants. Particles are examined under a powerful optical microscope to determine the size, concentration, color, shape and particle composition. Results received from Trico s analytical ferrography provide for the application of timely, corrective maintenance, based on a machine s actual condition. Wear Debris Analysis BENEFITS: Determine start of abnormal wear assess the severity, origin, and development mechanism of particles Evaluate particles contaminating the lubricant sample Predict equipment wear condition and failure potential Qualitatively determine the size, shape, composition, and concentration of particles Identify source of wear Determine lubricant life Particle analysis -3 microns Spheres Bearing fatigue prior to spalling Chunks Fatigue, scuffing or scoring of gear teeth Laminar Wear Rolling contact failure Fibers Paper filter failure

5 Other Equipment Specific Analysis Trico Corporation 9555 Rockside Rd. Suite 35 Cleveland, OH Phone: Fax: =Normal/Accept 2=Slight 3=Marginal 4=Serious 5=Critical/Reject Fe Cu Pb Sn Cleveland, OH 211 Trico Corporation (*) - Test performed by a Trico Corporation contracted ISO 1725 Accredited Laboratory MARGINAL CRITICAL Si Na B K trending and diagnostics Trico s Total Laboratory Solutions includes online reporting software which shows you how to get the most from your test data. The Total Laboratory Solutions includes your personal condition monitoring report where you receive test data results immediately after the sampling process is complete. You can manage your data and your condition monitoring program efficiently and effectively. Our reporting capabilities integrate various condition monitoring services into a single, comprehensive report. Reports are ed immediately following analysis and review. Active links within the will direct you to the analysis portion of your condition monitoring report. Total Laboratory Solutions reporting system is an easy to use point & click program that allows you to select any test data from any sample point location and equipment you wish to review. You will see sample severity levels such as normal, marginal, and critical indicated by color. Posting the results by color allows for fast and immediate identification of equipment that needs attention. Providing the opportunity to focus your resources where needed most to help keep your condition monitoring program on target within your goals. Through regular monitoring and trending you will receive information needed to continually maximize asset reliability. Problems can be identified, through condition monitoring report, by comparing an equipment s most recent samples to its historical data. Equipment Specific Analysis Trico Corporation 9555 Rockside Rd. Suite 35 Cleveland, OH Phone: Fax: RECOMMENDATIONS: CONDITION REPORT LOCATION ID: 2 Conv GBX DESCRIPTION: BXY COMPONENT: Gearcase LUBRICANT: Mobilgear 6 XP 32 RESERV. CAP: 8 Gallons LUBE TIME: Hours TEST SUITE: ABC MACH HRS: Hours This unit will remain at a CRITICAL rating based on the high lead level. Also note the abnormal wear rate and the presence of excess wear debris and contamination. Consider changing the oil in this unit. REPORT RATINGS: PHYSICAL/CHEMICAL PROPERTIES: PARTICULATES: TRACE ELEMENTS: Equipment Contaminants Any Company Cleveland, OH Additives CRITICAL ECR LCR MARGINAL CRITICAL SAMPLE DATE: 6/1/211 REC'D DATE: 6/6/211 REPORT DATE: 6/6/211 SPID #: CNTL #: ANALYST: Kennedy BATCH #: Rating Viscosity (4C) Contaminants in ppm Wear Metals in ppm CONDITION REPORT Any Company LOCATION ID: 2 Conv GBX DESCRIPTION: BXY COMPONENT: Gearcase LUBRICANT: Mobilgear 6 XP 32 RESERV. CAP: 8 Gallons LUBE TIME: Hours TEST SUITE: ABC MACH HRS: Hours Wear Particle Trend Sample Date 3/2/21 7/27/21 1/7/211 2/1/211 3/1/211 4/3/211 6/1/211 Limits Ratings Marginal Marginal Marginal Critical Critical Critical Critical Lubricant Out of Range Out of Range Reference Low High Visc 4C, cst Visc 1C, cst Alert Alarm Viscosity Index Color Crackle, Water N N N N N N N Crackle, Refridg. N N N N N N N Water(KF), ppm Water(%) Water(FTIR), abs Oxidation(abs) Nitration(abs) TAN(mg KOH) TBN(mg KOH) * RPVOT (Minutes) Alert Alarm ISO 446 PC DR Trend Soot Alert Alarm Iron Chromium Aluminum Copper 1 Lead Tin Silver Nickel 1 1 Silicon Sodium Potassium Boron Molybdenum 1 1 Magnesium Calcium Barium Phosphorus Zinc Cadmium 1 1 Vanadium 1 Titanium 211 Trico Corporation (*) - Test performed by a Trico Corporation contracted ISO 1725 Accredited Laboratory 1.2 SAMPLE DATE: REC'D DATE: REPORT DATE: SPID #: CNTL #: ANALYST: BATCH #: CRITICAL ECR LCR 6/1/211 6/6/211 6/6/ Kennedy Rating Contaminants Copper Low Alloy Medium Alloy White Rating Babbitting Metal High Alloy Case Hardened Rubbing < 15 Sliding Cutting Gear Bearing Spheres Blk Oxides Red Oxides Corrosive Other Image # 1 2X WEAR PARTICLE ANALYSIS: The wear particle concentration increased from 21. to 428., and is now of concern. The large abnormal wear particles detected in the previous sample are no longer present. However, there are also increased amounts of wear debris, dirt, corrosive wear (oil additive depletion and acidic lubricant), and amorphous residue (degradation) contamination seen in this sample. This unit will remain at a CRITICAL rating based on the high lead level. Also note the abnormal wear rate and the presence of excess wear debris and contamination. Consider changing the oil in this unit. ANALYTICAL RESULTS: This picture shows the excess steel rubbing wear debris and contamination observed in this sample. Equipment Specific Analysis Trico Corporation 9555 Rockside Rd. Suite 35 Cleveland, OH Phone: Fax: LOCATION ID: 2 Conv GBX DESCRIPTION: BXY COMPONENT: Gearcase LUBRICANT: Mobilgear 6 XP 32 RESERV. CAP: 8 Gallons LUBE TIME: Hours TEST SUITE: ABC MACH HRS: Hours Rubbing Sliding Cutting Gear Bearing Other Trico Corporation (*) - Test performed by a Trico Corporation contracted ISO 1725 Accredited Laboratory Max um Max um Rating CONDITION REPORT Any Company Cleveland, OH SAMPLE DATE: 6/1/211 REC'D DATE: 6/6/211 REPORT DATE: 6/6/211 SPID #: CNTL #: ANALYST: Kennedy BATCH #: < 15 Lube Degrad Sand/Dirt Fibers Cont Spheres Other CRITICAL ECR LCR MARGINAL CRITICAL condition monitoring report: 1.2 No special software required; can be used with any web browser Individual test results are color coded to give more meaning to the report Data is presented graphically, with trends clearly tracked by sample dates and machine hours Analysis is provided in detail, with interpretations based on trend analysis Recommendations are precisely summarized Color images depicting actual wear particle conditions are provided customer comments can be posted on the report, prior to internal distribution, in response to action items recommended by the Trico s Machine Condition Analysts Customer comments and report are permanently stored Sample result summaries are sent via immediately following analysis and review. Active links within the direct you to your condition monitoring report notification and 24/7 result availability from the web

6 TRICO BUILDING INDUSTRIAL LUBRICATION CUSTOMERS FOR LIFE If you re looking to prevent machine failure, enhance machine performance and gain a competitive edge, Trico offers the full line of predictive analysis technologies you need. Our Total Laboratory Solutions will analyze the condition of your oil and equipment without shutting you down. For more information contact Trico at trico corporation 1235 hickory street pewaukee, wi trico laboratory 9555 rockside road cleveland, oh

Services SAMPLE SUMMARY REPORT DR. PUMP, LLC Isuzu Rodeo. Atlanta, GA 05/24/2007

Services SAMPLE SUMMARY REPORT DR. PUMP, LLC Isuzu Rodeo. Atlanta, GA 05/24/2007 SAMPLE SUMMARY REPORT 7 Portage Trail 8.48.R 7 E A L 5.6.7 Fax:.6.7 44. 57 Report Date: 5/4/7 Primay Contact: Dr. Lev Nelik, PhD 977 Four Oaks Drive 6-75 Secondary Contact: None Provided Voice: None Provided

More information

EQUIPMENT REPAIR REPORT

EQUIPMENT REPAIR REPORT EQUIPMENT REPAIR REPORT Date: January, 2011 Customer: Page 1 of 14 Our Reference: Sales order #5000005320 Subject: Gould s AC - SRL-C Slurry Pump 14x12-29 Discharge Bottom Left When viewed from drive end

More information

Par-Test. Fluid Analysis

Par-Test. Fluid Analysis Fluid Analysis 195 Fluid analysis has proven to be a critical tool for any preventive maintenance program. Fluid analysis is able to identify potential problems that cannot be detected by human senses.

More information

Test It, Don t Change It On-site Oil Analysis Solutions. Candice Brown, Spectro Incorporated

Test It, Don t Change It On-site Oil Analysis Solutions. Candice Brown, Spectro Incorporated Test It, Don t Change It On-site Oil Analysis Solutions Candice Brown, Spectro Incorporated Machine failures are very costly sometimes spectacular, and the lubricant is a common cause of failure 2 Mechanical

More information

Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc.

Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc. Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc. mkiley@analystsinc.com 09/16/2016 What is Oil Analysis Oil analysis is the sampling and laboratory

More information

EQUIPMENT PARTICLE ANALYSIS

EQUIPMENT PARTICLE ANALYSIS Sample ID: TAM-ST Sample Date: Equip. Desc.: Storage Tank Received Date: 7/20/2000 Reservoir Cap.: 3000 Gal.(s) 11355 L(s) Prev. Sample: #REF! UKN Machine Time: Not Prov Hrs. First Sample: Lube Time: Not

More information

Xamine Oil Analysis Program User Guide

Xamine Oil Analysis Program User Guide Asset Reliability Solutions Xamine Oil Analysis Program User Guide Asset Reliability Solutions www.lelubricants.com 800-537-7683 Xamine Oil Analysis Program Saves Money with Consistent, Accurate Monitoring

More information

Fluid Analysis for Bearing Reliability

Fluid Analysis for Bearing Reliability Fluid Analysis for Bearing Reliability Question: Why Oil Analysis.? Answer: To improve the lives of Maintenance & Reliability Engineers.. An effectively executed fluid analysis program eliminates the guesswork,

More information

Ferrography/oil analysis: An excellent condition monitoring technique

Ferrography/oil analysis: An excellent condition monitoring technique WEBINARS Jeanna Van Rensselar / Senior Feature Writer Ferrography/oil analysis: An excellent condition monitoring technique Techniques to diagnose and predict equipment health without taking the machine

More information

T-700 DF 4110V PARTICULATE-WATER & FILMING REMOVAL FILTRATION ELEMENT

T-700 DF 4110V PARTICULATE-WATER & FILMING REMOVAL FILTRATION ELEMENT T-700 DF 4110V PARTICULATE-WATER FILMING REMOVAL FILTRATION ELEMENT THE FOLLOWING PAGES DEMONSTRATE THE PERFORMANCE OF FILMAX FILTRATION ELEMENT. THIS FILTRATION ELEMENT REMOVES WATER BOTH FREE DISSOLVED

More information

Cat EMSOLUTIONS: Levels

Cat EMSOLUTIONS: Levels CAT EQUIPMENT MANAGEMENT SOLUTIONS uncover the value you need Cat EMSOLUTIONS Cat EMSOLUTIONS: Levels The five levels of service ensure you get the support you need, whether you prefer to do your own maintenance

More information

BEST PRACTICES FOR AN EFFECTIVE OIL ANALYSIS PROGRAM

BEST PRACTICES FOR AN EFFECTIVE OIL ANALYSIS PROGRAM BEST PRACTICES FOR AN EFFECTIVE OIL ANALYSIS PROGRAM STLE HOUSTON OCTOBER 14, 2016 RAY THIBAULT/MARK KAVANAUGH MAINTENANCE PROGRAMS EQUIPMENT MAINTENANCE STRATEGIES Maintenance Strategy Activity Strategy

More information

Fluid Analysis. What Can Fluid Analysis Do For You? Suggested Sampling Intervals and Methods

Fluid Analysis. What Can Fluid Analysis Do For You? Suggested Sampling Intervals and Methods Fluid Analysis What Can Fluid Analysis Do For You? Fluid analysis is a snapshot of what is happening inside your equipment. It summarizes the condition of your oil and identifies component wear and contamination

More information

Introduction. Adverse Affects

Introduction. Adverse Affects Particulate Contamination Identifying, Eliminating and Removing it. TRICO CORPORATION 1235 Hickory Street, Pewaukee, WI 53072-3999 Ph 262.691.9336 or 800.558.7008 www.tricocorp.com In an ideal world, bearings

More information

OFFLINE FILTRATION SERVICE

OFFLINE FILTRATION SERVICE OFFLINE FILTRATION SERVICE Unlike many other filtration services, Precise Lubrication offers filtration which will: Improve cleanliness levels Reduce moisture content Remove harmful by-products of oxidation

More information

Industrial Solutions

Industrial Solutions The Science of Fluid Analysis Fast. Simple. Accurate. Industrial Solutions On-site Oil Analysis for Machine Condition Monitoring In-service oil analysis is a key machine condition monitoring technique.

More information

LABORATORY TURNAROUND TIMES AND CHARGES

LABORATORY TURNAROUND TIMES AND CHARGES LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush

More information

Laboratory Turnaround Times and Prices

Laboratory Turnaround Times and Prices 4619 N. Santa Fe Ave. Oklahoma City, OK 73118 (405) 488-2400 Laboratory Turnaround Times and Prices The enclosed prices reflect a five (5) business day turnaround. There will be a minimum charge of $25.00

More information

CSI Oil Analysis Options

CSI Oil Analysis Options Product Data Sheet May 2003 Machinery Health Management CSI Oil Analysis Options n CSI Oil Laboratory provides accurate and comprehensive industrial oil analysis results you can import directly intothe

More information

OIL/WEAR PARTICLE ANALYSIS A PREDICTIVE MAINTENANCE TOOL

OIL/WEAR PARTICLE ANALYSIS A PREDICTIVE MAINTENANCE TOOL OIL/WEAR PARTICLE ANALYSIS A PREDICTIVE MAINTENANCE TOOL By Ray Dalley, PREDICT USA Cleveland, Ohio Abstract Wear particle analysis and Ferrography in particular is an effective means to identify and respond

More information

Wear Particle Atlas CD-ROM

Wear Particle Atlas CD-ROM Wear Particle Atlas CD-ROM Database of Wear & Contaminant Particles in Used Lubricants Introduction The Wear Particle Atlas CD-ROM is a new comprehensive computer database of wear particles found in all

More information

Solutions for Power Generation and Industrial Plants

Solutions for Power Generation and Industrial Plants Solutions for Power Generation and Industrial Plants Identify problems early Prevent machinery damage Increase asset lifetime In-service Oil Analysis for Machine Condition Monitoring Since the reliable

More information

Diesel Engine Coolant Analysis, New Application for Established Instrumentation

Diesel Engine Coolant Analysis, New Application for Established Instrumentation Diesel Engine Coolant Analysis, New Application for Established Instrumentation Daniel P. Anderson, Malte Lukas and Brian K. Lynch Spectro Incorporated 160 Ayer Road Littleton, MA, 10460-1103 U.S.A. (978)

More information

RITES Lab, Western Region, 210, Amit Industrial Estate, 61, Dr. S.S. Rao Road, Parel, Mumbai, Maharashtra

RITES Lab, Western Region, 210, Amit Industrial Estate, 61, Dr. S.S. Rao Road, Parel, Mumbai, Maharashtra Last Amended on - Page 1 of 5 I. METALS & ALLOYS 1. Low-Alloy Steel Carbon ASTM E 415-08/ Manganese ASTM E 415-08/ Silicon ASTM E 415-08/ Sulphur ASTM E 415-08/ Phosphorous ASTM E 415-08/ Chromium ASTM

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS BAY 3, 4500 5TH STREET NE CALGARY, AB CANADA T2L 7C3 MAXXAM JOB #: A814851 Received: 2008/04/02, 13:15 Matrix: Water # s Received: 1 This report supersedes all previous reports with the same Maxxam job

More information

Oil Analysis Lessons Learned. Chad Norris Refrigeration Engineer Wells Dairy, Inc.

Oil Analysis Lessons Learned. Chad Norris Refrigeration Engineer Wells Dairy, Inc. Oil Analysis Lessons Learned Chad Norris Refrigeration Engineer Wells Dairy, Inc. Oil Analysis Lessons Learned Oil Analysis Methods Internal vs. External Oil Analysis Reports What info do I need? Wear

More information

Oil Analysis Provides Information Vital to Determining Root Cause of Water Contamination in Industrial Gearboxes

Oil Analysis Provides Information Vital to Determining Root Cause of Water Contamination in Industrial Gearboxes Oil Analysis Provides Information Vital to Determining Root Cause of Water Contamination in Industrial Gearboxes A Case Study by Analysts, Inc. Author: Charles Gay Certified Lubrication Specialist OMA

More information

Fluid Analysis Service Report

Fluid Analysis Service Report Vickers Proactive Maintenance Document o.586 April, Fluid Analysis Service Report RUST OXIDIZED METAL STEEL ALUMIUM BROZE COMPAY Hydraulic Fluid Services COTACT PERSO ADDRESS Maintenance Manager 6 orthwestern

More information

Improving Machinery Productivity with Oil Debris Sensing

Improving Machinery Productivity with Oil Debris Sensing Improving Machinery Productivity with Oil Debris Sensing Reducing maintenance costs while increasing machinery productivity is a balancing act that maintenance engineers constantly try to reconcile. Condition

More information

Reusable Oil Filters: An Eco- Logical Alternative

Reusable Oil Filters: An Eco- Logical Alternative Reusable Oil Filters: An Eco- Logical Alternative prepared by: Charles E. Button, Environmental Programs Manager Environmental Programs Division Physical Plant Department University of North Carolina at

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Hatchwood Place Farnham Road Odiham Hampshire RG29 1AB Contact: Mr R Medhurst Tel: +44 (0)1256 704000 Fax: +44 (0)1256 704006 E-Mail: enquiries@spectro-oil.com Website: www.spectro-oil.com Testing performed

More information

OIL PURIFICATION SYSTEM

OIL PURIFICATION SYSTEM OIL FILTRATION SYSTEMS, INC. 111 Parkway Drive, Boerne, Texas 78006 Phone: 830-816-3332 Fax: 830-816-3331 Web: oilfiltrationsystems.com VACUUM DEHYDRATION OIL PURIFICATION SYSTEM The harmful effects of

More information

Appendix C: Water Quality Data

Appendix C: Water Quality Data Appendix C: Water Quality Data Your Project #: 111257005 Site: TIM HORTONS SYLVIA LAKE NSD # 16300R Attention: DAVID WHETTER STANTEC CONSULTING LTD 603-386 BROADWAY AVENUE WINNIPEG, MB CANADA R3C

More information

Fluid Trending Service

Fluid Trending Service Introducing HYDAC S s Clean oil is the key to long equipment life, precision operation, lower maintenance costs and decreased downtime. HYDAC s s can unlock the door to increased savings by detecting potential

More information

Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000

Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000 C112-0514M Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000 Copper alloys are designated by their chemical composition with characteristic properties such as high corrosion resistance,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Hatchwood Place Farnham Road Odiham Hampshire RG29 1AB Contact: Mr R Medhurst Tel: +44 (0)1256 704000 Fax: +44 (0)1256 704006 E-Mail: enquiries@spectro-oil.com Website: www.spectro-oil.com Testing performed

More information

ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR

ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR Abstract Pentair Additives are introduced into lubrication and hydraulic oils in order to minimize the rate of wear occurring in costly

More information

um"ts: m1 1grams per rt1er (mg./l)

umts: m1 1grams per rt1er (mg./l) 28 Clark Avenue St. Louis, MO 633-257 4 (314) 531-8080 FAX (31 4) 531-8085 P.O. Box 897 Page 1of8 REPORT OF ALYSIS ID: WATER NO. 1-1 5 T FLOOR BREAKROOM, 05/09/16 um"ts: m1 1grams per rt1er (mg./l) ANION

More information

Drinking Water Analyses

Drinking Water Analyses Environmental & Analytical Services 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES AND PRICE LIST, JANUARY 2016 TO DECEMBER 2016 Drinking Water Analyses BACTERIOLOGICAL

More information

CERTIFIED REFERENCE MATERIALS (CRM)

CERTIFIED REFERENCE MATERIALS (CRM) CERTIFIED REFERENCE MATERIALS (CRM) Sufficiently Homogenized Indian Reference Materials certified by Round robin analysis for the use of validation of methods and calibration. CSIR-National Metallurgical

More information

CERTIFICATE OF ANALYSIS REVISED REPORT

CERTIFICATE OF ANALYSIS REVISED REPORT Your C.O.C. #: A122303 Attention: STEPHEN LEGAREE EDMONTON 9331 9331-48 Street EDMONTON, AB CANADA T6B 2R4 Report #: R1787645 Version: 2R CERTIFICATE OF ANALYSIS REVISED REPORT MAXXAM JOB #: B4B4991 Received:

More information

4th Edition BASICS OF OIL ANALYSIS

4th Edition BASICS OF OIL ANALYSIS CORPORATE OFFICE 3401 Jack Northrop Ave. Hawthorne, CA 90250 800-336-3637 SOUTHEAST 3075 Corners N. Ct. NW Norcross, GA 30071 800-241-6315 MID CONTINENT 11350 Bluegrass Pkwy. Louisville, KY 40299 800-491-6063

More information

Analysis of Cast Iron Using Shimadzu PDA-7000

Analysis of Cast Iron Using Shimadzu PDA-7000 Analysis of Cast Iron Using Shimadzu PDA-7000 C112-0510M The analysis of low and high alloy cast iron by optical emission spectrometry is presented. Cast iron alloys are classified by their mechanical

More information

ElvaX Light for Petrochemical analysis

ElvaX Light for Petrochemical analysis ElvaX Light for Petrochemical analysis Introduction ElvaX Light is a powerful and productive instrument for analysis of petroleum products, such as automotive fuels (gasoline, diesel), lubricating oil,

More information

Participate in proficiency testing studies semi-annually, with the following exception

Participate in proficiency testing studies semi-annually, with the following exception July 02, 2015 Mr. Dave Wunderlich Eurofins Frontier Global Sciences 11720 North Creek Parkway North, Suite 400 Bothell,WA 98011 Dear Mr. Wunderlich: Thank you for your application for renewal in the Environmental

More information

Solutions for Power Generation and Industrial Plants

Solutions for Power Generation and Industrial Plants Solutions for Power Generation and Industrial Plants Maximize machine uptime Extend oil drains Prevent premature failures In-service Oil Analysis for Machine Condition Monitoring Since the reliable operation

More information

Used Oil Analysis Data from Wind Turbine Gear Reducers Helps Define Achievable Oil Drain Intervals

Used Oil Analysis Data from Wind Turbine Gear Reducers Helps Define Achievable Oil Drain Intervals Used Oil Analysis Data from Wind Turbine Gear Reducers Helps Define Achievable Oil Drain Intervals Rick Russo, Kevin Harrington, Sandra Legay, ExxonMobil Fuels, Lubricants & Specialties Marketing Wind

More information

Alloy Steels. Engineering Materials. Introduction : Msc. Shaymaa Mahmood

Alloy Steels. Engineering Materials. Introduction : Msc. Shaymaa Mahmood Alloy Steels Introduction : Steels are, essentially, alloys of iron and carbon, containing up to 1.5 % of carbon. Steel is made by oxidizing away the impurities that are present in the iron produced in

More information

Eco Flow Fluid Analysis Program

Eco Flow Fluid Analysis Program TRUCK FLEETS Eco Flow Fluid Analysis Program SCHOOL BUSES Powered By Exttend oiill change iintterrvalls Exttend equiipmentt lliiffe EARTH MOVING EQUIPMENT IIdenttiiffy miinorr prrobllems befforre tthey

More information

TOGA Electrical Insulating Fluid Analysis. Improving performance and protecting assets.

TOGA Electrical Insulating Fluid Analysis. Improving performance and protecting assets. TOGA Electrical Insulating Fluid Analysis Improving performance and protecting assets. It happens all the time - transformers fail unexpectedly, and there are often no external visual clues on what caused

More information

Appendix C1: Batch Kinetics Tests

Appendix C1: Batch Kinetics Tests Appendix C1: Batch Kinetics Tests This appendix contains the entire data set for the batch kinetics tests for the potential biofilter components. These tests were performed to provide estimates of optimal

More information

Understanding Oil Analysis: How It Can Improve Reliability of Wind Turbine Gearboxes Michael P. Barrett and Justin Stover

Understanding Oil Analysis: How It Can Improve Reliability of Wind Turbine Gearboxes Michael P. Barrett and Justin Stover technical Understanding Oil Analysis: How It Can Improve Reliability of Wind Turbine Gearboxes Michael P. Barrett and Justin Stover Historically, wind turbine gearbox failures have plagued the industry.

More information

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to: April 11, 2017 Mr. Brad Barfuss 350 Hills Street Suite 107 Richland, WA 99354 Dear Mr. Barfuss: Thank you for your application for renewal in the Environmental Laboratory Accreditation Program. Enclosed

More information

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation Matrix: CWA (Non Potable Water) Discipline EPA 120.1 Chemistry Conductivity 8/1/2015 Aluminum 8/1/2015 Antimony 8/1/2015 Arsenic 8/1/2015 Barium 8/1/2015 Beryllium 8/1/2015 Boron 8/1/2015 Cadmium 8/1/2015

More information

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to: April 9, 2015 Ms. Elisa Nguyen Energy Northwest Environmental Services Lab 350 Hills Street Suite 107 Richland,WA 99354 Dear Ms. Nguyen: Thank you for your application for renewal in the Environmental

More information

Safety Data Sheets (SDSs) Soon To be Avalable for Purchase from AFS

Safety Data Sheets (SDSs) Soon To be Avalable for Purchase from AFS Steel SC002 High Alloy Steel Chromium (Cr) 10.0 52.0 7440 47 3 Cobalt (Co) 0 2.5 7440 48 4 Copper (Cu) 0 4.0 7440 50 8 Iron (Fe) Remainder 7439 89 6 Manganese (Mn) 0.3 6.0 7439 96 5 Molybdenum (Mo) 2.0

More information

OSA4 Oil Analyzer System

OSA4 Oil Analyzer System ~ 1 ~ OSA4 Oil Analyzer System Technical Specifications for the OSA4 On Site Oil Analyzer On-Site Analysis, Inc 7108 Fairway Drive Palm Beach Gardens, FL 33418 Table of Contents ~ 2 ~ I. System Overview...

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Alpha Resources, LLC 3090 Johnson Road Stevensville,

More information

Metallurgy of Aluminum Die Casting Alloys EC 305 Dave Neff

Metallurgy of Aluminum Die Casting Alloys EC 305 Dave Neff Metallurgy of Aluminum Die Casting Alloys EC 305 Dave Neff Dave Neff OUTLINE Where aluminum comes from Why alloys are useful Alloy designation and nomenclature Specific roles of alloy elements Properties

More information

Advanced Lubrication Technology, Inc. Index of Product Test Reports

Advanced Lubrication Technology, Inc. Index of Product Test Reports Advanced Lubrication Technology, Inc. Index of Product Test Reports d the tests and produced the reports listed below: A) Analysts, Inc. G) Herguth Laboritories, Inc. B) Argonne National Laboratory H)

More information

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/ 6360 Gateway Drive, 90630 95073 Page 1 of 8 CI-516 Cistanche 361439388 ICP MS Full Mineral Screen EPA 3050/6020 USP730 BRN Aluminum 2.2 ppm (w/w) Antimony Arsenic 0.06 ppm (w/w) Barium 0.09 ppm (w/w) Beryllium

More information

Importance of condition monitoring:

Importance of condition monitoring: Advanced Materials Manufacturing & Characterization Vol3 Issue 1 (2013) Advanced Materials Manufacturing & Characterization journal home page: www.ijammc-griet.com Condition Monitoring of Steam Turbine

More information

Water Monitoring - Teralba Quarry EPA Point No.4 - Adit Overflow

Water Monitoring - Teralba Quarry EPA Point No.4 - Adit Overflow No. Dates Water Monitoring - Teralba Quarry - 2018 - EPA Point No.4 - Adit Overflow EPA No 4-148 ABCDE EPA No 4-149 ABCDE EPA No 4-150 ABCDE January 2018. Febrary 2018. March 2018. EPA No 4-151 AB April

More information

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation Matrix: CWA (Non Potable Water) Discipline: Chemistry ASTM D516-07 ASTM D6888-09 ASTM D7511-09e2 EPA 160.4 EPA 1631E EPA 1664A EPA 1664A (SGT-HEM) EPA 180.1 Sulfate 8/1/2018 Cyanide, Amenable 8/1/2018

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EXOVA INC., DBA ELEMENT MATERIALS TECHNOLOGY Products Warren Laboratory 1920 Concept Dr. Warren, MI 48091-1385 N Jeri Laird Phone: 248 458 5900 x 73258 Fax:

More information

#287 FOOD GRADE FLUSHING AGENT

#287 FOOD GRADE FLUSHING AGENT #287 FOOD GRADE FLUSHING AGENT Food Grade Flushing Agent is a non-toxic, non-drying, anti-wear flushing and cleaning lubricant that can be used to clean and flush all types of processing and packaging

More information

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road October 27 2010 Inorganics Fluoride 1.5 MAC 0.17 0.13

More information

The objective of this document is to specify the chemicals characteristics and properties of the material Steel AISI Carbon Steel.

The objective of this document is to specify the chemicals characteristics and properties of the material Steel AISI Carbon Steel. STEEL AISI - 2 Steel AISI 2. Carbon Steel. Carbon C.8.23 Manganese Mn.3.6 Phosphorus P -.4 Max Sulfur S -.5 Max FM-DO-CO-2 3/3/27 STEEL AISI - 862 Steel AISI 862. Carbon Steel. Carbon C.7.23 Silicon Si

More information

Between "ferrogram" and "filtergram" makers is the multiple centrifiltergram maker: a new technique for solid debris separation

Between ferrogram and filtergram makers is the multiple centrifiltergram maker: a new technique for solid debris separation Journal of Physics: Conference Series Between "ferrogram" and "filtergram" makers is the multiple centrifiltergram maker: a new technique for solid debris separation To cite this article: S Raadnui 2012

More information

BUREAU VERITAS Oil & Petrochemicals. Oil Analysis. Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis

BUREAU VERITAS Oil & Petrochemicals. Oil Analysis. Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis BUREAU VERITAS Oil & Petrochemicals Oil Analysis Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis In-Service Used Oil & Lubricant Analysis Routine oil and coolant analysis identifies

More information

Networked Protection of Productivity: HYDAC CM-Expert.

Networked Protection of Productivity: HYDAC CM-Expert. Networked Protection of Productivity: HYDAC CM-Expert. CM-Expert: Monitoring which HYDAC CM-Expert: Online monitoring of production systems. Directly on-site or via remote inquiry. Regardless of the application,

More information

Specification Aluminium Die-Casting Alloy, high silicon content Aluminium Die-Casting Alloy, high silicon content

Specification Aluminium Die-Casting Alloy, high silicon content Aluminium Die-Casting Alloy, high silicon content Specification 2012-10 Class: Aluminium and Al-alloys Class No.:21 Aluminium Die-Casting Alloy, high silicon content JED 853 Previous Edition Part name (for databases) 2011-11 Aluminium Die-Casting Alloy,

More information

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE VHG Labs Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE Committed To Our Customers Our Mission Statement: VHG Labs provides superior value to our customers

More information

2019 Microbac Laboratories Inc. Ohio Valley Division

2019 Microbac Laboratories Inc. Ohio Valley Division STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES LABORATORY CERTIFICATION BRANCH In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10)

More information

A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses

A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses Jian G. Ding Lubrosoft P/L P 0 Box 2368, Rowville Melbourne VIC 3178 Australia (61-3) 9759-9083 Abstract: A new computerised wear

More information

Ferrography A procedure for measuring wear rate

Ferrography A procedure for measuring wear rate Indian Journal of Engineering & Materials Sciences Vol. 15, October 2008, pp. 377-381 Ferrography A procedure for measuring wear rate N Govindarajan a * & R Gnanamoorthy b a Flat B, Raj Enclave, Balaji

More information

Bottom Ash Data Week 45

Bottom Ash Data Week 45 Bottom Ash Data 2018 Week 45 The following analytical report was sent to the Ministry of Environment and Climate Change Strategy on November 21, 2018. The data represents bottom ash composite results for

More information

Bottom Ash Data Week 52

Bottom Ash Data Week 52 Bottom Ash Data 2018 Week 52 The following analytical report was sent to the Ministry of Environment and Climate Change Strategy on January 10, 2019. The data represents bottom ash composite results for

More information

BLACK STURGEON LAKES WATER QUALITY MONITORING

BLACK STURGEON LAKES WATER QUALITY MONITORING BLACK STURGEON LAKES WATER QUALITY MONITORING 2017 REPORT Prepared by: Ryan Haines, B.Sc. Biologist and Project Management Kenora Resource Consultants Inc. Site 155, Compartment 14, RR #1 Kenora, ON P9N

More information

HAIR ELEMENTS. PATIENT: Number 496 SEX: Female AGE: 70. POTENTIALLY TOXIC ELEMENTS TOXIC RESULT REFERENCE PERCENTILE ELEMENTS µg/g RANGE 68 th 95 th

HAIR ELEMENTS. PATIENT: Number 496 SEX: Female AGE: 70. POTENTIALLY TOXIC ELEMENTS TOXIC RESULT REFERENCE PERCENTILE ELEMENTS µg/g RANGE 68 th 95 th HAIR ELEMENTS PATIENT: Number 496 AGE: 70 POTENTIALLY TOXIC ELEMENTS TOXIC ELEMENTS µg/g RANGE 68 th 95 th Aluminum 2.4 < 7.0 Antimony < 0.01 < 0.050 Arsenic 0.042 < 0.060 Barium 0.27 < 2.0 Beryllium

More information

Specification ALLOYED STEEL FOR QUENCHING AND TEMPERING, HIGH STRENGTH All.steel f.quen.a.temp, h.str.

Specification ALLOYED STEEL FOR QUENCHING AND TEMPERING, HIGH STRENGTH All.steel f.quen.a.temp, h.str. Class: Heat-treatable steel Specification 16-09 ALLOYED STEEL FOR QUENCHING AND TEMPERING, HIGH STRENGTH Class No.:11 JED 723 Previous Edition Abbreviated Title 15-07 All.steel f.quen.a.temp, h.str. 8

More information

Bottom Ash Data Week 47

Bottom Ash Data Week 47 Bottom Ash Data 2018 Week 47 The following analytical report was sent to the Ministry of Environment and Climate Change Strategy on December 6, 2018. The data represents bottom ash composite results for

More information

CERTIFICATE OF ANALYSIS REVISED REPORT

CERTIFICATE OF ANALYSIS REVISED REPORT Your C.O.C. #: XXXXXXXX Attention: 23 MAIN ST, CITY, PROVIE COUNTRY POSTAL CODE Report Date: 5/09/7 Report #: XXXXXXXX Version: 2 - Revision MAXXAM JOB #: XXXXXXX Received: 5/09/03, 5:9 Sample Matrix:

More information

NORKOOL Industrial Coolants

NORKOOL Industrial Coolants NORKOOL Industrial Coolants The most trusted brand in the business The NORKOOL Advantage The NORKOOL product line is Dow s premium heat transfer fluid for gas compression engines and line heaters. the

More information

The role of Oil Analysis in Predictive Maintenance The role of Oil Analysis in Predictive Maintenance

The role of Oil Analysis in Predictive Maintenance The role of Oil Analysis in Predictive Maintenance The role of Oil Analysis in Predictive Maintenance Gwyn Simmonds, POLARIS Laboratories Question: Why Oil Analysis.? Answer: To improve the lives of Maintenance & Reliability Engineers.. An effectively

More information

CALA Directory of Laboratories

CALA Directory of Laboratories CALA Directory of Laboratories Membership Number: 2635 Laboratory Name: Taiga Environmental Laboratory Parent Institution: Government of Northwest Territories (GNWT) Address: P.O. Box 1320 4601-52nd Avenue

More information

Presentation to: Western Mining Electric Association

Presentation to: Western Mining Electric Association Presentation to: Western Mining Electric Association World s Largest Database of Test Records 4,000,000 Customer Transformer Test Records. World s Leading Reclaimer of Transformer Oil Over 1 Billion Gallons

More information

oil cleaner Electrostatic Product brochure

oil cleaner Electrostatic Product brochure Product brochure Turbotect Saint-Petersburg Ltd., Krasnogo Kursanta str., 11/1-2, Saint-Petersburg, Russia, 197110 tel.: +7-812-380-20-77 fax: +7-812-380-31-46 www.turbotectspb.com e-mail: info@turbotectspb.com

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Metals and Minerals Division 2 Perry Road Witham Essex CM8 3TU Contact: Mrs C Hargreaves Tel: +44 (0)1376 536800 Fax: +44 (0)1376 520819 E-Mail:

More information

Fluid Contamination Under Control...

Fluid Contamination Under Control... Fluid Contamination Under Control... DFE Rated Filter Element Upgrades Upgrade existing hydraulic and lube filter elements to Hy-Pro G7 Dualglass for cleaner fluid and improved reliability. Hy-Pro Elements

More information

Statistics valid as of January 2004.

Statistics valid as of January 2004. After completion each well typically requires initial fracturing (fracing) operation to realize maximum gas production with additional fracing every few years. Statistics valid as of January 2004. Basic

More information

CHEMOLUBE H WATER-GLYCOL FIRE RESISTANT FLUIDS PRODUCT DESCRIPTION

CHEMOLUBE H WATER-GLYCOL FIRE RESISTANT FLUIDS PRODUCT DESCRIPTION CHEMOLUBE H WATER-GLYCOL FIRE RESISTANT FLUIDS PRODUCT DESCRIPTION CHEMOLUBE H fluids are specially formulated, water-glycol based products designed for industrial application. CHEMOLUBE H fluids at the

More information

The World s Most Versatile Filter System

The World s Most Versatile Filter System The World s Most Versatile Filter System Full-flow filtration systems By-pass filtration systems Water Based Fluids Process Fluids Heating oils Turbine oils Bioethanol Hippo Filter Biodiesel Kerosene Diesel

More information

CHEVRON SOLUBLE OIL B

CHEVRON SOLUBLE OIL B CHEVRON SOLUBLE OIL B PRODUCT DESCRIPTION Chevron Soluble Oil B is used broadly in machine shops as a multifunctional cutting fluid. It is primarily formulated to cool and lubricate the contact point of

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS Attention:Simon Palmer 3567 East Road Denman Island, BC CANADA V0R T0 Your Project #: COMPREHENSIVE 7 Your C.O.C. #: G86 Report Date: Report #: R2435 Version: Final MAXXAM JOB #: B754384 Received: 7/07/05,

More information

RE-REFINED ENGINE OIL BOTTOMS (REOB) & POLYPHOSPHORIC ACID (PPA) IN HOT MIX. 89 th Annual Transportation Short Course

RE-REFINED ENGINE OIL BOTTOMS (REOB) & POLYPHOSPHORIC ACID (PPA) IN HOT MIX. 89 th Annual Transportation Short Course RE-REFINED ENGINE OIL BOTTOMS (REOB) & POLYPHOSPHORIC ACID (PPA) IN HOT MIX 89 th Annual Transportation Short Course Table of Contents 1 What is REOB and PPA? 3-4 2 Problems with Using REOB and PPA 5-6

More information

Analyzing Lubricant and Machinery Condition Using Q5800 Portable Oil Analysis Lab

Analyzing Lubricant and Machinery Condition Using Q5800 Portable Oil Analysis Lab WHITE PAPER Analyzing Lubricant and Machinery Condition Using Q5800 Portable Oil Analysis Lab Overview The United States Marine Corps (USMC) maintains a fleet of thousands of mechanized vehicles consisting

More information

Bureau Veritas. Oil & Petrochemicals. Oil Analysis. Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis

Bureau Veritas. Oil & Petrochemicals. Oil Analysis. Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis Bureau Veritas Oil & Petrochemicals Oil Analysis Maintain Equipment Reliability With Expert Used Oil & Lubricant Analysis In-Service Used Oil & Lubricant Analysis Routine oil and coolant analysis identifies

More information

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016 Raw Potable Well Analysis: 2006-2016 Grid Analysis: 2009 & 2016 Sun Peaks, British Columbia Sun Peaks Utilities Co., Ltd. 1280 Alpine Road Sun Peaks, BC V0E 5N0 Tel: 250-578-5490 Fax: 250-578-5516 Email:

More information

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520 Corrosion Studies on GeoBrom HG520 Vapor Space Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive

More information