Pre Delivery & Installation Guide GX 480 GX 480 DT GX 480 APC GX 480 DT APC GX 600 GX 800 GX 1000

Size: px
Start display at page:

Download "Pre Delivery & Installation Guide GX 480 GX 480 DT GX 480 APC GX 480 DT APC GX 600 GX 800 GX 1000"

Transcription

1 Pre Delivery & Installation Guide GX 480 GX 480 DT GX 480 APC GX 480 DT APC GX 600 GX 800 GX 1000 Document number Issue B November 2006 Page 1

2 CONTENTS Page INTRODUCTION 3 MACHINE DELIVERY 4 INSTALLATION 5 MACHINE FOOTPRINT 6 MACHINE GROSS WEIGHT 9 LIFTING & MOVING THE MACHINE 10 GROUNDING THE MACHINE 12 POWER SUPPLY REQUIREMENTS 13 ELECTRICAL POWER CONNECTION 14 ELECTRICAL CABINET 14 PNEUMATIC CONNECTION 14 REMOVING THE SHIPPING BRACKETS 15 PREPARING THE COOLANT SYSTEM 18 COOLANT TANK CAPACITY 19 INSTALLING THE CHIP CONVEYOR (OPTION) 20 MACHINE DIMENSIONS 20 APC PALLET DIMENSIONS 31 TOOLING SYSTEM 32 TRAINING 32 Page 2

3 INTRODUCTION The contents of this document have been prepared to help you ensure the best possible installation. IMPORTANT :- Nothing in this document or in accompanying literature, drawings, charts or letters, implies the existence of a contract between yourself and Hardinge. The information given is believed to be accurate but you are reminded that no claim for damage, delay or cost incurred from the use of this information will be accepted by Hardinge. If there are items upon which you are unsure, or questions you may have which are not covered within the document, please do not hesitate to contact us. The telephone number is (0116) Ask for the Machine Order Department or contact your local distributor. Your co-operation in making two telephone calls is sought immediately after installation is completed, so that commissioning of the machine can be concluded without delay, and to arrange for your training. The telephone numbers and contacts are:- For commissioning: ask for the Service Department (0116) For training: ask for the Application Department (0116) You may of course have made alternative arrangements for all or part of the delivery, installation, commissioning and training. If so, we hope that you will still find the information in this document of value. To assist your planning for the future maintenance of your machine, we have included a chart indicating oils and greases required, together with the coolant system capacity. Thank you for choosing Bridgeport by Hardinge. Should you require additional clarification to ensure the successful installation of your Bridgeport Vertical Machining Centre, please contact:- Hardinge Machine Tools Ltd, Whiteacres, Cambridge Road Whetstone Leicester, LE8 6BD England. Tel: Fax: Hardinge Inc. One Hardinge Drive Elmira, New York USA Tel: Fax: Hardinge Taiwan 4 Tzu Chiang 3rd Rd, Nan Tou City, 540 Taiwan Tel: , Ext 104 & 108 or Your Local Distributor. Page 3

4 MACHINE DELIVERY If you have selected to have your machine delivered by Hardinge there are a number of points upon which we need information. NOTE :- If access is difficult, please advise us whereupon you will be contacted in order that arrangements for a visit from a representative of our haulers can be made. They will decide the most appropriate method of accessing your plant. Please use the following information to assess the suitability of our transport. Do not hesitate to call if in doubt. Telephone number (0116) Ask for the Machine Order Department. The machine will be delivered on a crane lorry by our haulers who are contracted to deliver and off-load at the nearest point of access at your premises, and then install the machine inside your premises. The vehicle specification is as follows:- Overall length including cab (36ft) 11.0m Length of deck (24ft) 7.3m Width of deck (8ft) 2.4m Height of deck (4.5ft) 1.4m Overall height of crane (MIN) 4.1m NOTE :- When operating the vehicle crane, its hydraulic legs will be extended to steady the lift. This will increase the width by an additional (4ft) 1.2m. To determine the total loaded height of the vehicle, check the above information together with the overall dimensions of your machine illustrated in this document. It is in everyone s interest to ensure that the off-loading is completely possible. We do urge you to check carefully and to discuss with us areas of doubt. If on arrival our vehicle is unable to off-load the machine, delays and additional charges could arise. Lifting Equipment As the machine is to be lifted by Fork Truck it is recommended that the minimum capacity be 10,000kg with a minimum tine length of 1,200mm. Page 4

5 INSTALLATION To assist you the following points should be carefully considered. Check the packing list as soon as you are able to ensure that all items have been delivered. If there are shortages call us on (0116) Ask for the Machine Order Department. The following information is provided for your guidance. 1. Foundation Requirements A solid foundation is required to bear the machine weight. Any friable areas should be made good using recognized building construction techniques. If doubt exists, consult your building architect. Do not locate the machine near equipment that causes vibration. Poor cutting or damage to the control may result from vibration transmitted to the machine. 2. Uncrating (where necessary) Carefully remove the outer casing, internal braces and skids so that the machine is not damaged in any way. Should damage have occurred in transit inform: i) the haulage contractor ii) iii) the railways and/or shippers, or local agent and state the full extent of the damage. Retain all the packing materials until the Insurance Company s assessor has inspected the machine. 3. Leveling Procedure a) Make sure the location of the machine is exactly where you need it to be. Ensure allowance for access for operation, cleaning and maintenance is provided. See the installation dimensional drawing for minimum clearances. See pages 19 ~ 29 for machine outline drawings b) Locate the floor pads which are packed with the associate kit and position them on the floor under each jack bolt. When satisfied lower the machine gently onto the pre-located pads. Ensure jack bolts are screwed down to provide a 15 to 20mm gap from the underside of the base casting to the floor. c) If you use skates then employ the jack bolts with suitable support packing to raise the machine enough to remove the skates and finally set onto the floor pads. Page 5

6 MACHINE FOOTPRINT GX 600, 800 & 1000 Page 6

7 GX 480, GX 480 DT Page 7

8 GX 480 APC, GX 480 DT APC NOTE: Dimensions are shown in inches (millimeters) Page 8

9 Jacking screws (all machines) M30 thread, with 32mm (1.1/4 ) A/F hexagon, and 41mm (1.5/8 ) A/F locknut Machine Number of jacking screws GX 600, 800 & GX 480 & GX 480 DT 6 GX 480 APC & GX480 DT APC 8 MACHINE GROSS WEIGHT (PACKED) (SHIPPING WEIGHT) Machine Model GX 480, GX 480 DT GX 480 APC, GX480 DT APC Standard and High Speed Machines 6,622 lb [3,010 Kg] 8,096 lb [3,680 kg] High Torque Machines GX ,254 lb [5,570 Kg] 12,474 lb [5,670 Kg] GX ,694 lb [5,770 Kg] 12,914 lb [5,870 Kg] GX ,024 lb [5,920 Kg] 13,244 lb [6,020 Kg] Page 9

10 LIFTING AND MOVING THE MACHINE (For GX 480 or GX 480 DT) (For GX 600/800/1000) Page 10

11 Machine Legs Under Table (GX 1000 Machine Shown) Tower Support Legs at Rear of Machine (GX1000 Machine Shown) Tower Support Legs at Rear of Machine (GX 480 Machines Shown) Page 11

12 GROUNDING THE MACHINE If an earth ground is to be installed, the customer must supply and install the ground rod, ground rod clamp, and ground conductor according to all applicable electrical codes. a) All VMC machines must be grounded in order to protect personel and the machine from electrical hazards. Grounding must be in accordance with the standards for electrical equipment. b) Ideally, the grounding point should be as close as possible to the machine. c) A qualified electrician must carry out the grounding work, otherwise serious injury, death, or accidents involving machine damage could result. d) The machine must be grounded in one of the following ways: 1) Independent grounding 2) Common grounding Regardless of the type of grounding system used, the earth loop impedance of the supply, which connects the machine to ground/earth, must not exceed 1 ohm. Page 12

13 e) Never ground the machine in the manner shown in the illustration below. No more than one grounding conductor wire can be connected to a single terminal. If the grounding conductors are connected in the manner shown in the illustration above, a faulty connection at one of the terminals could cause grounding current to be fed back to the machine, resulting in serious accidents. NOTE:- We are unable to assist with electrical cable selection as this depends upon your particular site. Your qualified electrical engineer will be able to calculate the correct needs from the power supply requirement chart. Once the electrical and air supplies are provided make the connection to the machine. The delivery dimensional drawing gives details of input locations. POWER SUPPLY REQUIREMENTS Heidenhain Fanuc Siemens Voltage 220V 400V 220V 400V 220V 400V Full load Full load Full load kw kw kw current (amps) current (amps) current (amps) APC Page 13

14 ELECTRICAL POWER CONNECTION Consult the local utility supply company to determine exact service and wiring requirements for your area. A qualified electrician must carry out the connection of the mains electrical supply to the machine. ELECTRICAL CABINET Earth (ground) wire connections 3 Phase supply (no neutral required) PNEUMATIC CONNECTION Unit Value Pressure bar > 5.0 Flow rate ( STANDARD m/c) Litres / Min > 453 Flow rate ( high speed spindle) Litres / Min >650 Dew point (at ATM. Pressure) C -17 or lower Note: The air supply must be clean (40micron particulate size) and dry. Do not connect direct to a compressor with a short pipe as water/oil may condense out and cause a potential seizure of the spindle bearings through the air purge circuit. An air drier unit is recommended. The minimum recommended bore size for the air supply pipe is 10mm Page 14

15 REMOVING THE SHIPPING BRACKETS X and Y Axes Some machines have a separate shipping bracket for the X and Y axes. Both brackets (M & N) are located near the front of the table. Other machines have one shipping bracket, O, centered on the tower at the rear of the table. DO NOT thread any of the screws back into their holes after removing the shipping brackets. Separate X Axis and Y Axis Shipping Brackets One X and Y Axes Shipping Bracket Page 15

16 Tool Changer Carousel (Tool Magazine) Shipping Bracket Operator Control Panel Operator Control Panel Shipping Bracket and Pendant Thread the screws back into the pendant support and tighten them. Page 16

17 Pallet Changer (GX 480 APC & GX 480 DT APC) DO NOT thread any of the screws back into their holes after removing the shipping brackets. D Secondary table F APC hinge arm Loosen the clamping bolts (F) and remove the wooden clamp APC hinge arm shipping bracket (D) Page 17

18 PREPARING THE COOLANT SYSTEM 1. Roll coolant tank S, into the opening under the front of the machining center. 2. Install the coolant hose and tighten the clamps. 3. Pour the coolant directly into the chip pan of the coolant tank. Fill the tank with the approved coolant to the FULL line of the sight gauge. Coolant Tank (For GX 480 or GX 480 DT) s Coolant Tank (For GX 600/800/1000) Page 18

19 COOLANT TANK CAPACITY Coolant tank capacity GX 480, 100 liters (27 gallons) GX 480 DT GX liters (62 gallons) GX 800/ liters (97 gallons) INSTALLING THE CHIP CONVEYOR (OPTION) 1. Roll the coolant tank out. 2. Lift out the chip trays, chip pan and filters (screens) from the coolant tank. 3. Set the chip conveyor into the coolant tank. 4. Plug one end of the cable into the connector on the chip conveyor. 5. Replace the coolant tank with chip conveyor into the opening. 6. Attach the coolant hose to the coolant tank. 7. Plug the other end of the chip conveyor cable into the connector located on the bottom of the power case. Page 19

20 AIR MANUALMODEODEHARDINgE AUTOMPUSH MACHINE DIMENSIONS GX 480 and GX 480 DT Machining Center Dimensional Drawings Size GX 480 GX 480 DT A B C D E F 1681 ~ ~ ~2323(CTS) G H Page 20

21 GX 600 Machining Center HARDINgE GX 600 Machining Center Front View Page 21

22 GX 600 Machining Center Top View Page 22

23 GX 600 Machining Center Right Side View Page 23

24 GX 800 and GX 1000 Machining Centers HARDINgE GX 800 Machining Centers Front View Page 24

25 HARDINgE GX 1000 Machining Center Front View Page 25

26 GX 800 /1000 Machining Centers Top View Page 26

27 GX 800 /1000 Machining Centers Right Side View Page 27

28 MANUALMODEAUTOMODEGX 480 APC and GX 480 DT APC Machining Centers GX 480 APC and GX 480 DT APC Machining Center Front View Dimensional drawing Dimension A B C D E F G H GX 480 APC ~ ~ (CTS) GX 480 DT APC ~ Page 28

29 GX 480 APC and GX 480 DT APC Machining Center Top View Dimensional drawing Dimension A B C D E F G H GX 480 APC ~ ~ (CTS) GX 480 DT APC ~ Page 29

30 PUSH GX 480 APC and GX 480 DT APC Machining Center Right Side View Dimensional drawing Dimension A B C D E F G H GX 480 APC ~ ~ (CTS) GX 480 DT APC ~ Page 30

31 APC PALLET DIMENSIONS Page 31

32 TOOLING SYSTEM Spindle Collet Toolholder Pullstud Dimension, E 40 taper MAS 403 BT-40 MAS 403 BT-40 NV A ISO 7388/1 NV A ANSI B5.50 NV A CAT (5/8 UNC) NV A DIN DIN B NV A 34 mm 30 taper MAS 403 BT-30 MAS 403 BT-30 ANSI B5.50 CAT (1/2 UNC) DIN NV J NV J NV J NV J 28 mm TRAINING Please telephone the Application Department (0116) for details of courses, delegates fees, hotel reservations etc. Your earliest attention to this matter is requested as places on our training courses are limited. Full joining instructions for delegates will be forwarded prior to the course date. Page 32

Gerber. Scientific Products. Dear Gerber Sabre Customer:

Gerber. Scientific Products. Dear Gerber Sabre Customer: Gerber Scientific Products 151 Batson Drive, Manchester, CT 06040 (860) 643-1515 Dear Gerber Sabre Customer: Thank you for purchasing the Sabre, Gerber Scientific Products advanced, high-speed, three-dimensional

More information

Gerber Scientific Products

Gerber Scientific Products Page 1 of 9 Sabre Series Router Pre-Installation Checklist Gerber FastFact # 5003 Supplied by: Gerber Service Last Modified: June 28, 2012 Summary: This document provides the Pre-Installation for your

More information

XPM 2. Reflow Soldering / Curing Systems. Site Preparation & Installation

XPM 2. Reflow Soldering / Curing Systems. Site Preparation & Installation XPM 2 Reflow Soldering / Curing Systems Site Preparation & Installation Site Preparation & Installation 1 Revision Date: May 2004 Table of Contents SITE PREPARATION CHECKLIST 3 ROOM PLANNING 4 Oven Clearances

More information

PRE-INSTALLATION MANUAL. February 2015

PRE-INSTALLATION MANUAL. February 2015 PRE-INSTALLATION MANUAL FOR i-series MACHINES February 2015 Pre-Installation Manual for i-series Machines v387 February 2015 The information in this document is subject to change without notice and does

More information

Gerber M Series Site Requirements

Gerber M Series Site Requirements Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick

More information

HAAS SERVICE AND OPERATOR MANUAL ARCHIVE

HAAS SERVICE AND OPERATOR MANUAL ARCHIVE Haas Technical Publications Manual_Archive_Cover_Page Rev A June 6, 2013 HAAS SERVICE AND OPERATOR ARCHIVE Operators Manual 96-0012 RevE English June 2002 This content is for illustrative purposes. Historic

More information

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations... www.standardchange.com 1-800-968-6955 Technical Phone Support is from 8:00AM to 7:30PM E.S.T., Monday-Friday Walk-in Service is from 8:00AM to 4:30PM E.S.T., Monday-Friday Parts Department is from 8:00AM

More information

This document provides the Pre-Installation Checklist for the ADVANTAGE Router 600.

This document provides the Pre-Installation Checklist for the ADVANTAGE Router 600. Page 1 of 13 ADVANTAGE Router TM 600 Pre-Installation Checklist Gerber FastFact # 5008 Supplied by: Gerber Service Last Modified: October 29, 2001 Summary: This document provides the Pre-Installation Checklist

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL Pneumatic Wheel Lift Model: RWL-50T REV. A PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO INSTALLATION AND OPERATION. BY PROCEEDING YOU AGREE THAT YOU FULLY UNDERSTAND AND COMPREHEND THE FULL

More information

for Phoenix II-1 Human Cremation Retort

for Phoenix II-1 Human Cremation Retort Installation Manual for Phoenix II-1 Human Cremation Retort Please Read Carefully Before Installing. Any Questions? Please Call! Failure to install properly may VOID your warranty. NOTICE: Specifications

More information

MF M/C Cell. MF400C/U Cell (120ATC+40APC) MF500C/U Cell (120ATC+28APC)

MF M/C Cell. MF400C/U Cell (120ATC+40APC) MF500C/U Cell (120ATC+28APC) MF M/C Cell MF400C/U Cell (120ATC+40APC) MF500C/U Cell (120ATC+28APC) MF Cell The Cell is designed for applying in mixed production and flexibility. The highest appreciate on 2nd/3rd shift unmanned operation.

More information

for BLP 200/75 Animal Cremation Retort

for BLP 200/75 Animal Cremation Retort Installation Manual for BLP 200/75 Animal Cremation Retort Please Read Carefully Before Installing. Any Questions? Please Call! Failure to install properly may VOID your warranty. NOTICE: Specifications

More information

Pre-installation Manual CONCEPT 301 D/401 D/501 D

Pre-installation Manual CONCEPT 301 D/401 D/501 D Pre-installation Manual CONCEPT 301 D/401 D/501 D Pre-installation Manual CONCEPT 301 D/401 D/501 D Concept 301 D T11416 Edition BA, January 2015 This book has part No 10077155 0-2 This manual is published

More information

You will need to have Coolant on hand at the time of installation. Contact our Service Department with any questions.

You will need to have Coolant on hand at the time of installation. Contact our Service Department with any questions. 15150 25th Avenue North, Minneapolis, MN 55447-1981 Phone 763-476-8600 Fax 763-476-4092 For Service: MN 763-476-4191 IA 319-632-4288 NE 402-330-2323 Visit us at: Hwww.productivity.comH Productivity is

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS SINGLE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS SINGLE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS SINGLE-PHASE PADMOUNTED TRANSFORMERS Original Issue 1/84 Revised 1/91 Revised 6/02 Revised 11/05 Revised 11/09 Revised 1/12 Revised 11/12 Revised 5/14 Revised

More information

Festoon Manual Heavy Duty C-Track

Festoon Manual Heavy Duty C-Track Festoon Manual Heavy Duty C-Track 966300.3 Heavy Duty C-Track Manual CONDUCTIX INCORPORATED The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES,

More information

Installation. Natrix

Installation. Natrix Installation Natrix Table of Contents 1 Prerequisites for Installation Site... 2 1.1 On-site Delivery and Insertion at Ground Level... 2 1.2 On-site Delivery and Insertion via Ramp... 2 1.3 Intermediate

More information

11, 000- L b. E x t r e m e - D u t y P a l l e t Tr u c k OWNER S MANUAL

11, 000- L b. E x t r e m e - D u t y P a l l e t Tr u c k OWNER S MANUAL 11, 000- L b. E x t r e m e - D u t y P a l l e t Tr u c k OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules

More information

Horizontal M/C Cell. HX504 Cell(240ATC+8APC) HX505 Cell(150ATC+8APC)

Horizontal M/C Cell. HX504 Cell(240ATC+8APC) HX505 Cell(150ATC+8APC) Horizontal M/C Cell HX504 Cell(240ATC+8APC) HX505 Cell(150ATC+8APC) HX Cell The Cell is designed to process a mix production in variety of different jobs. With high flexibility, it is a solution for small-volume

More information

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models:

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models: medixx Series Installation Guidelines Suitable for the following Siemens MRI Systems, or similar models: medixx 50: Symphony / Harmony Quantum and Aera (XJ gradient) medixx 60: Avanto, Espree, TaTs, Vero,

More information

ADJUSTABLE AIR HYDRAULIC SLIDING JACKBEAM 7000 lbs.

ADJUSTABLE AIR HYDRAULIC SLIDING JACKBEAM 7000 lbs. ADJUSTABLE AIR HYDRAULIC SLIDING JACKBEAM 7000 lbs. (217) INSTALLATION AND OPERATION MANUAL SAVE ALL INSTRUCTIONS READ ALL INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, OPERATING, SERVICING, OR MAINTAINING

More information

Installation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V

Installation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V Installation Smart-UPS VT in Parallel 10-40 kva 380/400/415 V 208/220 V 200/208 V Contents Safety... 1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS.............................. 1 Prepare for

More information

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer

More information

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

2200-Lb. Semi-Electric Stacker OWNER S MANUAL 2200-Lb. Semi-Electric Stacker OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

MTS Criterion Series 40

MTS Criterion Series 40 MTS Criterion Series 40 Manual Title Lifting and Moving Additional Instructions Information be certain. 100-231-444 C Copyright information Trademark information Proprietary information Software validation

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO INSTALLATION AND OPERATION. BY PROCEEDING YOU AGREE THAT YOU FULLY UNDERSTAND AND COMPREHEND THE FULL CONTENTS OF THIS MANUAL. FORWARD THIS MANUAL

More information

Pre-Delivery Instructions

Pre-Delivery Instructions Congratulations on your decision to enjoy the finest Aquatic Fitness System available... Welcome to the growing family of ENDLESS POOLS owners. Pre-Delivery Instructions Please take the time to read this

More information

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar INDEX 1. OWNER / USER RESPONSIBILITIES---------------------------------------- PAGE 3 2. SAFETY PROCEDURES---------------------------------------------------------

More information

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02 Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380

More information

210 Series UL Listed Modular Vault Panel Installation Procedures January 15, 2009

210 Series UL Listed Modular Vault Panel Installation Procedures January 15, 2009 210 Series UL Listed Modular Vault Panel Installation Procedures January 15, 2009 Model 210, UL Class M Model 211, UL Class 1 Model 212, UL Class 2 Model 213, UL Class 3 CAUTION EXTREMELY HEAVY THIS PRODUCT

More information

the P.R. Skate, LLC Pallet Rack Moving System Product Manual

the P.R. Skate, LLC Pallet Rack Moving System Product Manual the P.R. Skate, LLC Pallet Rack Moving System Product Manual the P.R. Skate, LLC Product Manual In this manual we will cover both normal operation of the P.R. Skate moving system and safety issues that

More information

You will need to have Coolant on hand at the time of installation. Contact our Service Department with any questions.

You will need to have Coolant on hand at the time of installation. Contact our Service Department with any questions. 15150 25th Avenue North, Minneapolis, MN 55447-1981 Phone 763-476-8600 Fax 763-476-4092 For Service: MN 763-476-4191 IA 319-632-4288 NE 402-330-2323 Visit us at: www.productivity.com Productivity is ISO

More information

INSTALLATION INSTRUCTIONS FOR. MODEL MSBULTB LED

INSTALLATION INSTRUCTIONS FOR. MODEL MSBULTB LED INSTALLATION INSTRUCTIONS FOR MODEL MSBULTB LED www.bsncp.com 1 Table of content Page # Description and Model number, packing list Installation Overview & specifications Mounting the scoreboard to the

More information

TeraFrame HD Cabinet System Supplemental Installation Guide

TeraFrame HD Cabinet System Supplemental Installation Guide TeraFrame HD Cabinet System Supplemental Installation Guide 800-834-4969 techsupport@chatsworth.com www.chatsworth.com 2010 Chatsworth Products, Inc. All rights reserved. CPI, TeraFrame and MegaFrame are

More information

MAX-RAK 246 INSTANTLY ADJUSTABLE PALLET RACK

MAX-RAK 246 INSTANTLY ADJUSTABLE PALLET RACK MAX-RAK 246 INSTANTLY ADJUSTABLE PALLET RACK WWW.RAPISTAK.COM Max-Rak 246 Instantly Adjustable Pallet Rack Features Removable and instantly adjustable steel fabricated pallets instead of fixed beam shelving.

More information

VIA BOWLING. File No.: M COPYRIGHT 2005, VIA BOWLING PRODUCTS

VIA BOWLING. File No.: M COPYRIGHT 2005, VIA BOWLING PRODUCTS VIA BOWLING File No.: M200510-01 COPYRIGHT 2005, VIA BOWLING PRODUCTS CONTENTS Warning --------------------------------------------------------------------------------------2 How to Use the Manual -----------------------------------------------------------------3

More information

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2 V 2.0 ASSEMBLY GUIDE Series 2 TABLE OF CONTENTS OVERVIEW General Specifications...1 Cautions and Disclaimers...1 Contents of Kit...1 Tools Required For Assembly...2 Time Required to Assemble...2 ASSEMBLING

More information

Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment.

Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment. RM070A-R3 RM080A-R3 Wallmount Frame User s Manual Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment. Customer Support Information Order toll-free

More information

Replace This With Cover PDF

Replace This With Cover PDF Replace This With Cover PDF Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation

More information

Quick Adjustable Height Stands

Quick Adjustable Height Stands Quick Adjustable Height Stands Installation, Maintenance & Parts Manual DORNER MFG. CORP. INSIDE THE USA OUTSIDE THE USA P.O. Box 0 975 Cottonwood Ave. TEL: -800-397-8664 TEL: 6-367-7600 Hartland, WI 5309-000

More information

TECHNICAL DATA SHEET DS 060

TECHNICAL DATA SHEET DS 060 of 9 General Notes: This instruction covers the installation of a resilient mounted system for a marine propulsion engine driving a rigidly mounted gearbox through a flexible coupling utilising an independent

More information

Installation Plan. Washer-extractor PW 6088 EL LP. en - AU M.-Nr

Installation Plan. Washer-extractor PW 6088 EL LP. en - AU M.-Nr Installation Plan Washer-extractor PW 6088 EL LP en - AU 14.14 M.-Nr. 09 923 540 Australia: Miele Australia Pty. Ltd. 1 Gilbert Park Drive KNOXFIELD Victoria 3180 Tel. +61 3 97647-100 Fax +61 3 97647-129

More information

Sun Fire E25K/E20K Systems Unpacking Guide

Sun Fire E25K/E20K Systems Unpacking Guide Sun Fire E25K/E20K Systems Unpacking Guide Read Me First Note After the Sun Fire E25K/E20K systems arrive, contact your local service provider. Installation, verification, and maintenance must be performed

More information

Operating Instructions April 2010 milltronics WD600

Operating Instructions April 2010 milltronics WD600 Operating Instructions April 2010 milltronics WD600 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected

More information

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions Thermatile Ten-Twelve Radiant Panels Installation instructions 2 IOM 53, Issue 6 - Thermatile TEN-TWELVE Contents Page 1 General 3 1.1 Description 3 1.2 Receipt and Preparation 3 1.3 Storage and Handling

More information

RHE3 Dock Leveler Installation Manual

RHE3 Dock Leveler Installation Manual RHE3 Dock Leveler Installation Manual MADE IN U.S.A. This Manual Covers Dock Levelers Built After Serial Numbers: 07FE160001M and up PRINTED IN U.S.A. RITE-HITE PRINT SHOP PUBLICATION NO. 1222 MAY 2007

More information

Installation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS

Installation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS Page 1 of 10 INDEX 1. Health & Safety 3 2. Introduction 3 3. Requirements 3 4. Working Area 3 5. Equipment 3 6. 2 and 3 metre tank above ground

More information

400 mm PALLET HORIZONTAL MACHINING CENTERS KH-41. Explore Horizontally

400 mm PALLET HORIZONTAL MACHINING CENTERS KH-41. Explore Horizontally 400 mm PALLET HORIZONTAL MACHINING CENTERS KH-41 Explore Horizontally Now Methods brings you KIWA Japan KH-41 The ideal entry into horizontal machining With KIWA s feature-rich package and affordable price,

More information

Giddings & Lewis FT / FTR Series, Floor-Type Horizontal Boring Mills

Giddings & Lewis FT / FTR Series, Floor-Type Horizontal Boring Mills Giddings & Lewis Application Support Part Processing Assistance New or existing parts will benefit from process review and optimization by Fives Giddings & Lewis runoff technicians. Quickly get new parts

More information

SKATEWHEEL FLOW RACK

SKATEWHEEL FLOW RACK SKATEWHEEL FLOW RACK 2 ASSEMBLY INSTRUCTIONS: Steel King Industries recommends that this product be assembled only by qualified personnel, experienced in assembly of storage racks, and knowledgeable of

More information

Ground Fault Protection. Medium Voltage Artificial Neutrals

Ground Fault Protection. Medium Voltage Artificial Neutrals Ground Fault Protection Medium Voltage Artificial Neutrals Installation and Maintenance Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472

More information

2200-Lb. Stacker. Fixed Straddle Leg OWNER S MANUAL

2200-Lb. Stacker. Fixed Straddle Leg OWNER S MANUAL 2200-Lb. Stacker Fixed Straddle Leg OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

VIBRATING CONVEYORS MODEL VMC

VIBRATING CONVEYORS MODEL VMC VM-3671 Installation, Operation and Maintenance Instructions VIBRATING CONVEYORS MODEL VMC ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1440 U.S.A. WORLD AUTHORITY IN ADVANCED TECHNOLOGY

More information

SITE PREPARATION GUIDE

SITE PREPARATION GUIDE DEDICATED 5 x10 UV LED FLATBED PRINTER SITE PREPARATION GUIDE The information contained herein is subject to change without notice. The only warranties for Novus Imaging products and services are set forth

More information

Pre-installation Manual. Plate Processor 68/85 Thermal

Pre-installation Manual. Plate Processor 68/85 Thermal Pre-installation Manual Plate Processor 68/85 Thermal Pre-installation Manual Plate Processor 68/85 Thermal T1965 Edition DC, October 2011 Part No 51280 68/85 PLATE PROCESSOR INTRODUCTION RESERVATIONS

More information

EU150-EU200-EU400 CRIMPER OPERATORS MANUAL

EU150-EU200-EU400 CRIMPER OPERATORS MANUAL EU50-EU00-EU00 CRIMPER OPERATORS MANUAL SAFETY PRECAUTIONS READ INSTRUCTIONS AND IDENTIFY ALL COMPONENT PARTS BEFORE USING CRIMPER KEEP HANDS AWAY FROM PINCH POINTS CONSULT HOSE AND FITTING MANUFACTURER

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

HL STOKER AUGER PACKER

HL STOKER AUGER PACKER HL STOKER AUGER PACKER SAFETY INSTALLATION OPERATION MAINTENANCE 1 OF 26 FOREWARD This manual has been prepared to assist you with your Choice Bagging Equipment, Ltd. bag packaging equipment. The text

More information

Platform stair lift PLG7

Platform stair lift PLG7 Platform stair lift PLG7 ORIGINAL-user manual Part 2: Assembly Instruction English Version 2.00 ASCENDOR GMBH Drautendorf 48 4174 Niederwaldkirchen Austria Tel.: +43 7231 40040 Fax: +43 7231 40040-590

More information

Bravo Platform Unpacking Guide

Bravo Platform Unpacking Guide This guide describes how to unpack the Bravo device from the shipping carton. Depending on the order, the shipment can include additional packages for the Bravo utilities, pipetting head, computer, and

More information

BINAR Quick-Lift System

BINAR Quick-Lift System BINAR Quick-Lift System Install and Training Original Document - July 1, 2015 1 What to expect The installation, set-up, and training process takes an average of 1.5 days (12 hours) per unit. On the first

More information

Agilent Technologies 7620-AS Sample Changer Site Preparation Checklist Hardware Site Preparation Specification

Agilent Technologies 7620-AS Sample Changer Site Preparation Checklist Hardware Site Preparation Specification Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Limelight Pulse Spa Installation Instructions

Limelight Pulse Spa Installation Instructions Limelight Pulse Spa Installation Instructions Thank you very much for your order. On purchasing your spa you gave us an estimated month of delivery, our installation department will contact you regarding

More information

GI India Automation and System Pvt.Ltd.

GI India Automation and System Pvt.Ltd. GI India Automation and System Pvt.Ltd. GI India Automation & systems Pvt. Ltd. specializes in design and manufacturing of standard and custom built systems, CNC interfacing modules and equipments to meet

More information

C Series Mechanical Pit Levelers. P.O. Box 338 Spring Hill, Tennessee fax:

C Series Mechanical Pit Levelers. P.O. Box 338 Spring Hill, Tennessee fax: C Series Mechanical Pit Levelers SM P.O. Box 338 Spring Hill, Tennessee 37174 1-800-251-3382 fax: 931-486-0316 www.pioneerleveler.com DO NOT install, operate or service product unless you have read and

More information

XN24 for Package Production. Site Preparation Guide XN24

XN24 for Package Production. Site Preparation Guide XN24 Site Preparation Guide 10-2014 XN24 Contents 1. Preface... 4 2. Change record...5 3. Introduction...6 3.1 Welcome...6 3.2 About Installation...6 4. Responsibilities... 4.1 Esko Responsibilities... 4.2

More information

CT-20 Conveyor Stacker

CT-20 Conveyor Stacker CT-20 Conveyor Stacker 5/2017 Assembly, Operation & Parts Manual First Edition TABLE OF CONTENTS SPECIFICATIONS 1 UNPACKING 1 CONTENTS 2 ASSEMBLY 3 SETUP AND OPERATION 4 PARTS 6 SPECIFICATIONS POWER FUSE

More information

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions. Axiom www.hsiheadwalls.com SURFACE MOUNTED ARRAY Patient Headwall Installation Instructions Installation Guidelines Tel: 925.427.7800 Fax: 925.427.0800 support@hsiheadwalls.com Hospital Systems Inc. 750

More information

VERsacourt LED Light System Installation Instructions

VERsacourt LED Light System Installation Instructions VERsacourt LED Light System Installation Instructions PART LIST TEE BAR ASSEMBLY 10 12 LIGHT ASSEMBLY (hardware included) EXTENSION COLLAR BASE POLE EXTENSION POLE ANCHOR PAGE 1 REQUIRED TOOLS AND MATERIALS

More information

ODYSSEY FLOOR MODEL. Owner s Manual. O-6400-F shown rev 118

ODYSSEY FLOOR MODEL. Owner s Manual. O-6400-F shown rev 118 Owner s Manual ODYSSEY FLOOR MODEL O-6400-F shown 67-1455 rev 118 3730 E. Southern Avenue, Phoenix, AZ 85040 USA 800-778-8779 Workhorseproducts.com 1 Table of Contents I. Introduction & Safety Information.

More information

Table of Contents Rebel 80. General Information

Table of Contents Rebel 80. General Information Table of Contents Rebel 80 General Information Section Page 1.1 Contents of the Manual ------------------------------------------------------------------------------ 1 1.2 Machine Data Plate -----------------------------------------------------------------------------------

More information

Standard Duty Cantilever Rack Installation and Assembly Guide

Standard Duty Cantilever Rack Installation and Assembly Guide Standard Duty Cantilever Rack Installation and Assembly Guide Steel King Industries, Inc. 2700 Chamber St Stevens Pont, WI 54481 (800) 826 0203 www.steelking.com info@steelking.com ASSEMBLY INSTRUCTIONS:

More information

ENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS

ENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS ENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS UNLOADING HANDLING ASSEMBLING Preface This instruction book is for your crews. Distribute it to help them safely unload and handle

More information

! CAUTION: Read and follow these instructions.

! CAUTION: Read and follow these instructions. OmniLog SAFETY AND INSTALLATION INSTRUCTIONS! CAUTION: Read and follow these instructions. Avoid Contact with Hazardous Live Parts WARNING: Risk of electrical shock. Refer servicing to qualified personnel.

More information

BESTMOVE STANDING TRANSFER AID

BESTMOVE STANDING TRANSFER AID BESTMOVE STANDING TRANSFER AID L.L.C. MODELS BestMove 400 BestMove 450 PRODUCT FEATURES *BestMove 450 shown Ensure the product has been assembled according to the instructions in this manual. OPERATING

More information

EXPRESS5800/1080Xd. Installation Procedures

EXPRESS5800/1080Xd. Installation Procedures EXPRESS5800/1080Xd () Installation Procedures Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable property

More information

Assembly, Installation & Watering Guide 6 PLANTER TRAY KIT. Product Version. Gro-Wall SLIM PRO. Document ID

Assembly, Installation & Watering Guide 6 PLANTER TRAY KIT.   Product Version. Gro-Wall SLIM PRO. Document ID Product Version Gro-Wall SLIM PRO Document ID MANUAL_6_PLANTER KIT_APR17 ATLANTIS GRO-WALL SLIM PRO Part Number : 80080 6 PLANTER TRAY KIT Assembly, Installation & Watering Guide www.gro-wall.com.au 2017

More information

Pre-Delivery Instructions

Pre-Delivery Instructions Congratulations on your decision to enjoy the finest Aquatic Fitness System available... Welcome to the growing family of ENDLESS POOLS owners. Pre-Delivery Instructions Please take the time to read this

More information

Model 5200 Cargo Lift Installation and Operation Manual

Model 5200 Cargo Lift Installation and Operation Manual Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household

More information

MODEL 185R Kontrol-Karrier Operator s Manual for Morse Kontrol-Karrier

MODEL 185R Kontrol-Karrier Operator s Manual for Morse Kontrol-Karrier Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Operating Instructions....................

More information

Power Distribution Center. Model: SUDC208V42P

Power Distribution Center. Model: SUDC208V42P Warranty Registration: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual Power Distribution Center Model: SUDC208V42P Note: This product requires

More information

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ

More information

VMC Series Vertical Machining Centers PARTNER FOR YOUR METAL-CUTTING SOLUTION

VMC Series Vertical Machining Centers PARTNER FOR YOUR METAL-CUTTING SOLUTION Vertical Machining Centers PARTNER FOR YOUR METAL-CUTTING SOLUTION Highlights The VMC Series The industry standard for a broad range of applications Heavy-duty and robust construction Compact design Available

More information

RIGIMILL BENEFITS OF THE RIGIMILL

RIGIMILL BENEFITS OF THE RIGIMILL BENEFITS OF THE The RigiMill was developed together with SECO tools to be the machine that can handle the fastest chip removal rate in the world for both titanium and aluminum Right-sized gantry for aluminum

More information

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

Bulk Bag Unloader Installation, Operation and Maintenance Manual

Bulk Bag Unloader Installation, Operation and Maintenance Manual Web-Tech Australia Pty Ltd Bulk Bag Unloader Installation, Operation and Maintenance Manual Web-Tech Australia Pty Ltd Manufacturers & Suppliers of Weighing, Level & Batching Equipment 11 Electronics Street

More information

CRON HDI-920 Site Planning. Customer Responsibilities

CRON HDI-920 Site Planning. Customer Responsibilities Customer Responsibilities CRON HDI-920 Site Planning You are responsible for providing the following items below to help ensure a trouble free installation. Adequate delivery access (i.e. Company Loading

More information

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount) INSTALLATION MANUAL FOOTWALL/SINKWALL (floor mount) OVERVIEW The Form is a UL-listed configurable footwall/sinkwall system. This system can include any combination of base cabinets, upper cabinets, wardrobes,

More information

MODEL 285A-HD Heavy-Duty Forklift-Karrier Operator s Manual for Morse Heavy-Duty Forklift-Karrier Model 285A-HD

MODEL 285A-HD Heavy-Duty Forklift-Karrier Operator s Manual for Morse Heavy-Duty Forklift-Karrier Model 285A-HD Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3-4 Operating Instructions....................

More information

FT / FTR Series, Floor-Type Horizontal Boring Mills

FT / FTR Series, Floor-Type Horizontal Boring Mills Metal Cutting Composites Giddings & Lewis FT / FTR Series, Floor-Type Horizontal Boring Mills Massive Part Machining Capabilities Capacity to handle industries largest parts with virtually unlimited X

More information

OPERATOR S SAFETY MANUAL

OPERATOR S SAFETY MANUAL June 2011 OPERATOR S SAFETY MANUAL Sumner Pipe Jacks www.sumner.com 7514 Alabonson Road Houston, TX 77088 U.S.A ph: 281.999.6900 fax: 281.999.6966 470 Collier MacMillan Drive Unit 2 & 3 Cambridge, ON N1R

More information

Services and Solutions for Mining

Services and Solutions for Mining Mining Solutions Services and Solutions for Mining Hydratight plays a leading role within the complex and changing world of global mining; providing innovative engineering solutions and unique services

More information

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems SEISMICALLY BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT DESIGN CRITERIA # 2 NON-STRUCTURAL ELEMENTS # 3 Restraint systems The next step in the non-specific design pathway in NZS

More information

OPERATION MANUAL BISON LIFTER (ABL150)

OPERATION MANUAL BISON LIFTER (ABL150) ABACO MACHINES OPERATION MANUAL BISON LIFTER (ABL150) ABACO MACHINES (USA) 14508 S. Garfield Ave., Paramount, CA 90723, USA Tel : 310-532-0366 Fax : 310-532-0499 Email : sales@abacomachines.com Website

More information

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions Thermatile Ten-Twelve Radiant Panels Installation instructions 2 IOM 53, Issue 7 - Thermatile TEN-TWELVE Contents Page 1 General 3 1.1 Description 3 1.2 Receipt and Preparation 3 1.3 Storage and Handling

More information

Basic Service. This Section provides information regarding a. Introduction

Basic Service. This Section provides information regarding a. Introduction Basic Service Introduction This Section provides information regarding a new electric Basic Service for a single phase service less than or equal to 400 amps, and a three phase service less than 50kW.

More information

Site Preparation Guide. Scodix Ultra Press and Scodix Ultra-Pro Press and Scodix Ultra Foil Station

Site Preparation Guide. Scodix Ultra Press and Scodix Ultra-Pro Press and Scodix Ultra Foil Station Site Preparation Guide Scodix Ultra Press and Scodix Ultra-Pro Press and Scodix Ultra Foil Station Important Notice Copyright 2012-2015 Scodix Ltd. All rights reserved. All product names are trademarks

More information

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48- 60- 72- 96 long Installation Instructions Supreme Air DYNAMIC BARRIER Bench Fume Hood H50 S T Y L E Fume Hoods 48"- 60"- 72"- 96" long Publication No. IIH50-SA 06/01 Part Number: IMAN-H50 Kewaunee Scientific Corporation

More information

Z5043 MAX Horizontal bracket Mounting instructions

Z5043 MAX Horizontal bracket Mounting instructions Z5043 MAX Horizontal bracket Mounting instructions Z5043 MAX Horizontal bracket References in the manual This refers to a potentially dangerous situation which may lead to personal injury. This refers

More information