QCP Pre-Insulated Aluminium Duct

Size: px
Start display at page:

Download "QCP Pre-Insulated Aluminium Duct"

Transcription

1 QCP Pre-Insulated Aluminium Duct Page 123

2 In the advanced world today, many different materials and systems have been developed as an alternative to the galvanized sheet metal traditionally used. One of the simplest, effective and economical alternatives is QCP Pre-Insulated Aluminium Duct. It specializes in the air distribution fields as well as other insulation purposes. QCP Pre-Insulated Duct is the solution to your needs. QCP Pre-Insulated duct is a double skin pre-insulated sandwich panel, made of PIR (Polyisocyanurate) which is composed of three layers. The top and bottom layers are made up of embossed aluminium foil of 80 microns in thickness. The middle layer is foam insulation material PIR - Polyisocyanurate 21mm Thick R1. It is fully tested to comply with all relevant standards by AWTA. BCA climate zone map The table below indicates the BCA requirements for each climate zone Location and element Minimum Total R-Value for ductwork Location Ductwork within a conditioned Space R1.2 R1.2 R1.2 R1.0 R1.2 R1.0 R1.0 R1.6 Ductwork exposed to Sun R3.0 R3.0 R3.0 R3.0 R3.0 R3.0 R3.0 R3.4 Ductwork in all other locations R2.0 R2.0 R2.0 R2.0 R2.0 R2.0 R2.0 R2.4 QCP Pre-Insulated Aluminium Duct offers extremely good consistency of density throughout the sheet. The QCP Pre-Insulated Aluminium Duct also has the foil applied in the initial manufacturing process ensuring an even and consistent application across the whole sheet & ensuring that the foil does not delaminate. The QCP Pre-Insulated duct is available in three forms. Board only, supplied in sheets 4000mm x 1200mm x 20mm to allow you or your customer to fabricate in house. Airtag is also offering the option of Flat Pack products & Fully Assembled products depending on your particular needs. We have invested in an efficient & highly accurate CNC Routing Machine that allows us to produce quickly, efficiently & cost effectively all product requirements including air conditioning & ventilation duct work. This together with a wide range in assembly extrusions, tools & ancillaries offers a full and comprehensive solution to all your needs. Page 124

3 QCP Pre-Insulated Aluminium Duct Description Size Pieces Price QCPB4000 QCP Board Only R1.0 (PIR) 4000mm x 1200mm x 20mm 6 QCP R1.0 Pre-Insulated Duct - Flat Packed Product Code Height QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA QCPBF POA POA POA POA POA POA POA POA POA POA BOX Flat Pack Please specify Size (Dia), location & number of spigots to allow for. No holes will be cut unless specified No castellated collars will be supplied unless specified. (Order separately, see ancillaries) All opening dimensions will be assumed as internal sizes unless otherwise stated. All heights will be assumed as overall unless otherwise stated No extrusions will be supplied unless requested. If required, H Extrusion is standard for all boxes unless specified otherwise. The allowance for spigots will be based on ovalised spigots (where required) unless specified. If spigot sizes required do not fit in the specified box size the box will automatically be made as a blown box & the price adjusted accordingly. All blown boxes will have central openings. Page 125

4 QCP R1.0 Pre-Insulated Duct - Manufactured Product Code Height QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA QCPBM POA POA POA POA POA POA POA POA POA POA BOX Manufactured Please specify Size (Dia), location & number of spigots (price includes a maximum of two spigots. Refer to ancillary section for additional catellated collar price). All opening dimensions will be assumed as internal sizes unless otherwise stated. All heights will be assumed as overall unless otherwise stated No extrusions will be supplied unless requested. If required, H Extrusion is standard for all boxes unless specified otherwise. The allowance for spigots will be based on ovalised spigots (where required) unless specified. If spigot sizes required do not fit in the specified box size the box will automatically be made as a blown box & the price adjusted accordingly. All blown boxes will have central openings. End Boot Heights - Based On Spigots Spigot Size mm Short End Of N/A N/A N/A N/A N/A Page 126

5 QCP R1.0 Pre-Insulated Duct V- 1-Way Flat Packed QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCP R1.0 Pre-Insulated Duct V- 2-Way Flat Packed QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCP R1.0 Pre-Insulated Duct V- 3-Way Flat Packed QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA QCPVBF POA POA V Flat Pack Please specify Size (Dia), location & number of spigots to allow for. No holes will be cut unless specified No castellated collars will be supplied unless specified. (Order separately, see ancillaries) All opening dimensions will be assumed as internal sizes unless otherwise stated. All boxes will have a 50mm skirt before taper. No extrusions will be supplied unless requested. If required, H Extrusion is standard for all boxes unless specified otherwise. The allowance for spigots will be based on ovalised spigots (where required) unless specified. If spigot sizes required do not fit in the specified box size the box will automatically made as a blown box & the price adjusted accordingly. All blown boxes will have central openings. Page 127

6 QCP R1.0 Pre-Insulated Duct V- 1-Way Manufactured QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCP R1.0 Pre-Insulated Duct V- 2-Way Manufactured QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCP R1.0 Pre-Insulated Duct V- 3-Way Manufactured QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA QCPVBM POA POA V Manufactured Please specify Size (Dia), location & number of spigots eg VB1, VB2 & VB3 (For larger supply plenums please enquire). All opening dimensions will be assumed as internal sizes unless otherwise stated. All boxes will have a 50mm skirt before taper. No extrusions will be supplied unless requested. If required, H Extrusion is standard for all boxes unless specified otherwise. The allowance for spigots will be based on ovalised spigots (where required) unless specified. If spigot sizes required do not fit in the specified box size the box will automatically made as a blown box & the price adjusted accordingly. All blown boxes will have central openings. Page 128

7 QCP Lay-In Diffuser Face Size Metric Nom Neck Metric Pieces/Carton Price QCPXLD4595F 595 x 595 Face 450 x $ Castellated Starting Collars Size Metric Size Imperial Price CSC $ 3.00 CSC $ 3.30 CSC $ 3.65 CSC $ 3.95 CSC $ 4.30 CSC $ 4.60 CSC $ 4.90 CSC $ 5.25 Please specify if you require collars to be spot welded. QCP Pre-Insulated Duct Extrusions Description Size Pieces Prices QCPHE h Extrusion PVC 4m Long 10 POA QCPHEE h Extension Extrusion PVC 4m Long 10 POA QCPFE F Extrusion PVC 4m Long 10 POA QCPCE C Extrusion PVC 4m Long 10 POA QCPIFE Invisible Flange (PVC) 4m Long 10 POA QCPIF90E Invisible Flange 90 Deg (PVC) 4m Long 10 POA QCPBE Bayonnet (PVC) 4m Long 10 POA QCPCA Cover Angle (PVC) POA QCPRR Re-Inforcement Bar (Aluminium) 4m Long 10 POA QCPSD Shaped Disc (Aluminium) POA QCPBJ Ball Joint (PVC) POA QCP Pre-Insulated Duct Tools & Accessories Description Price QCPGLUE 20 Litre Contact Adhesive POA QCPTB 4-Piece Tool (1 x V Cut 1 x 45 Deg Left 1 x 45 Deg Right & Straight Cut) QCPMBT Manual Bending Tool POA QCP4C 4m Bench Clamp POA QCP12C 1.2m Bench Clamp POA POA Page 129

Installation Guide QuietR Spiral Duct Liner

Installation Guide QuietR Spiral Duct Liner Table of Contents General Information 1-1 Recommendations and Limitations 2-1 Project Estimating 3-1 Grooving Duct Liner 4-1 Duct Liner Section 5-1 Adhesives Coatings and Pins 6-1 Straight Duct 7-1 Couplings

More information

TPO and PVC Roof Flashings and Accessories

TPO and PVC Roof Flashings and Accessories TPO and PVC Roof Flashings and Accessories FlashCap - Plumbers Flashings Standard sizes only: 1 1 /2, 2 3 and 4 of 25 minutes Cylindrical Plumbing Boots Available in all standard pipe sizes. Hose clamp

More information

FACILE. Hygienic sound attenuator for rectangular ducts QUICK FACTS

FACILE. Hygienic sound attenuator for rectangular ducts QUICK FACTS Hygienic sound attenuator for rectangular ducts QUICK FACTS Rectangular sound attenuator with extractable acoustic baffles. Used where there are stringent requirements for cleanability. ISOVER Cleantec

More information

Metal Panel & Spandrel Glass Design Guidelines

Metal Panel & Spandrel Glass Design Guidelines Metal Panel & Spandrel Glass Design Guidelines Quality, Comfort & Peace of Mind Quality, Comfort & Peace of Mind Foreword This Design Guide provides specifications on metal panels and spandrel glass used

More information

HAPRI. About us. What are the environmental benefits of Polyiso insulation?

HAPRI. About us. What are the environmental benefits of Polyiso insulation? INSULATION MATERIALS MANUFACTURING About us HAPRI Insulation Materials Manufacturing is one of the UAE Leading Thermal Insulation Company dealing in Polyurethane/Polyisocyanurate insulation, Pre-Insulated

More information

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017]

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017] KINGSPAN KOOLDUCT SYSTEM This Appraisal replaces BRANZ Appraisal No 771 (2012) s Technical Assessments of products for building and construction. Product 1.1 The Kingspan KoolDuct System is pre-insulated

More information

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 05.2011 Identification no: 02 09 05 01 200 0 120000 Version no. 04 Sarnafil S 327-12EL Polymeric membrane for roof waterproofing Construction Product Description Uses

More information

Elastomeric Rubber Foam Sheets/Rolls. Thickness

Elastomeric Rubber Foam Sheets/Rolls. Thickness www.heedgroup.net Elastomeric Rubber Foam Sheets/Rolls Thickness Roll Width Roll Roll Width Roll Elastomeric Rubber Foam Self Adhesive Sheets / Rolls Thickness Roll Width Roll Roll Width Roll NBR Elastomeric

More information

Total software solution for Ductwork & Duct Board manufacturing

Total software solution for Ductwork & Duct Board manufacturing Intelligent Fabrication Software ww.w.map-software.com The Total production solution for duct work manufacturing CAM-Duct is a total production solution that incorporates all the features necessary to

More information

KOMBI PVA KOMBI PVA 1 CC

KOMBI PVA KOMBI PVA 1 CC KOMBI PVA ** Radius of bend Max. supply pressure *D= Ø internal nominal Flame retardant (categoria II) - 10 C +120 C 0 Pa PVC/ALUMINIUM combined flexible duct that combines the high mechanical resistance

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PLASTIC DIFFUSERS AND GRILLES LINEAR ELITE DIFFUSER

PLASTIC DIFFUSERS AND GRILLES LINEAR ELITE DIFFUSER LINEAR ELITE DIFFUSER Clips supplied separately. Please specify. FEATURES Two 2mm slots provides high flow rates with low noise levels. One piece construction of the diffuser eliminates unsightly joins.

More information

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS General All Materials shall be EN, ISO or equivalent standard and shall be supplied from approved manufacturers. According to the International

More information

Luka Quality Assurance Manual (Eng)

Luka Quality Assurance Manual (Eng) Luka Quality Assurance Manual (Eng) Contents: 1 General... 3 1.01 Foreword... 3 2. Quality assurance standards for air ducts... 4 A.1.00 Rectangular galvanised steel ducts... 4 A.2.00 Embedded galvanised

More information

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947 WEATHER BREAKER MODEL 175 Whether you are keeping the cold out or in, nothing makes better sense for your manufacturing facility or warehouse

More information

LENTO. Angle sound attenuator for rectangular ducts QUICK FACTS

LENTO. Angle sound attenuator for rectangular ducts QUICK FACTS Angle sound attenuator for rectangular ducts QUICK FACTS Remarkably space-saving rectangular sound attenuator Excellent aerodynamic characteristics Very low pressure drop acoustic baffles serve as guide

More information

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands DUCTS - SEALING R-H-DS1 Mechanically Fasten Duct Sections Sections of metal duct should be mechanically fastened together after taping seams with UL 181 duct tape. Use sheet metal screws for rigid duct

More information

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 24.01.2017 Identification no: 02 09 05 01 202 0 150000 Sarnafil S 327-15EL Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

SECTION DUCT INSULATION

SECTION DUCT INSULATION SECTION 23 07 13 - DUCT INSULATION PART I - GENERAL 1.1 SECTION INCLUDES A. Ductwork Insulation B. Fan and Equipment Insulation C. Insulation Jackets D. Insulation Lagging 1.2 RELATED SECTIONS A. Section

More information

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION RUSKIN sand trap louvers are specially designed to separated the sand and dust from the air. It is effective and necessary to apply for ventilations and inlet

More information

Table of contents Our products We are offering three product groups: Quality and Service Our product groups Basic products-panels EURO, Light Version, Compensatory, Round Top Gates and Pedestrian Gates

More information

Nuaire Thermal Ducting

Nuaire Thermal Ducting Nuaire Thermal Ducting save time and use nuaire s design centre getting it right from the start The complete ventilation solution at every stage of your build. At Nuaire we understand the ever increasing

More information

PLASTIC FABRICATION. OUTPUT: Kg / h lb / h K-SB 20 K-SB 30 K-SB 40 R-SB Kg / h 11.2 lb / h. 3 Kg / h 6.6 lb / h. 4 Kg / h 8.

PLASTIC FABRICATION. OUTPUT: Kg / h lb / h K-SB 20 K-SB 30 K-SB 40 R-SB Kg / h 11.2 lb / h. 3 Kg / h 6.6 lb / h. 4 Kg / h 8. PLASTIC FABRICATION OUTPUT: Kg / h lb / h 2 Kg / h 4.4 lb / h 3 Kg / h 6.6 lb / h 4 Kg / h 8.8 lb / h 5 Kg / h 11.2 lb / h K-SB 20 K-SB 30 K-SB 40 R-SB 50 CUSTOMIZED PLASTIC FABRICATION USING THE STARGUN

More information

Palopaque. Wall Cladding Solutions. Tel: +44 (0) Fax: +44 (0)

Palopaque. Wall Cladding Solutions. Tel: +44 (0) Fax: +44 (0) Palopaque Wall Cladding Solutions Tel: +44 (0) 191 258 0777 Fax: +44 (0) 191 258 1010 Email: sales@bayplastics.co.uk Tel: +44 (0) 191 258 0777 Fax: +44 (0) 191 258 1010 Email: sales@bayplastics.co.uk Content

More information

HIGH BAY REFLECTOR. Series OPTIONAL ACCESSORIES MAXIMUM TEMPERATURES

HIGH BAY REFLECTOR. Series OPTIONAL ACCESSORIES MAXIMUM TEMPERATURES HIGH BAY REFLECTOR Series 84208 Crown Plastics 84208 High Bay Reflector is easily adapted to most LED, HID, induction and fluorescent high bay fixtures. Its shallow design doesn t impede wide beam angles

More information

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers. SECTION 23 37 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Tools for Pipe Welding

Tools for Pipe Welding E L D Tools for Pipe elding ELD-TECH ApS E L D PF Clamp LIFETIME ARRANTY ON BROKEN PARTS Stainless Steel The unique design of the PF Clamp gives an extremely strong clamp for fit-up of all types of pipes

More information

Volume Control Dampers. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) VOLUME CONTROL DAMPERS

Volume Control Dampers. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) VOLUME CONTROL DAMPERS VOLUME CONTROL DAMPERS DOA- QATAR - PONE: +- - +- - FAX: +- DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial

More information

RUUKKI FORMA DESIGN INSTRUCTION

RUUKKI FORMA DESIGN INSTRUCTION www.ruukki.com RUUKKI FORMA DESIGN INSTRUCTION 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION HVAC DUCTS AND CASINGS

SECTION HVAC DUCTS AND CASINGS SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 -GENERAL 1.1 SUMMARY A. Section includes metal ductwork, nonmetallic ductwork, casing and plenums, buried ductwork, kitchen hood ductwork, duct cleaning.

More information

Architectural Shadowline Air Diffusion

Architectural Shadowline Air Diffusion Architectural Shadowline Air Diffusion PSD Series Perimeter Slot Diffuser In cooling mode, diffuser selection should be based on the ratio of the diffusers throw to the length of the zone/area being supplied,

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

Fittings. Elbow Pipe. Specifications:

Fittings. Elbow Pipe. Specifications: Elbow Pipe This type of fitting is widely used in piping systems to connect two straight sections of pipes of equal or different nominal diameter and with a curvature at a certain angle to change its direction;

More information

AirBench EX Operation and Maintenance

AirBench EX Operation and Maintenance AIRBENCH LTD AirBench EX Operation and Maintenance This Edition: 10 February 2016 AirBench Ltd, 14 Grange Farm Road, Colchester CO2 8JW www.airbench.com +44 (0) 1206 791191 Copyright AirBench Ltd 2016

More information

Technical Submission Spiralite Pre-insulated Ductwork

Technical Submission Spiralite Pre-insulated Ductwork Technical Submission Spiralite Pre-insulated Ductwork This Spiralite technical submission and performance specification covers air-distribution HVAC ductwork systems and insulation requirements. It is

More information

Metal Roof Panels

Metal Roof Panels University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal

More information

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated. SECTION 23 07 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

LARGO. Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS

LARGO. Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS Angle sound attenuator with recessed connection for rectangular ducts QUICK FACTS Remarkably space-saving rectangular sound attenuator Excellent aerodynamic characteristics Very low pressure drop acoustic

More information

1000Introduction This specification details the design, materials, installation and commissioning standards for Underfloor Heating Systems.

1000Introduction This specification details the design, materials, installation and commissioning standards for Underfloor Heating Systems. Multipipe Underfloor Heating Specification 1000Introduction This specification details the design, materials, installation and commissioning standards for Underfloor Heating Systems. 2000Design Parameters

More information

PETREX -CNT. Pipe systems for petrol stations Technical details

PETREX -CNT. Pipe systems for petrol stations Technical details PETREX - Pipe systems for petrol stations Technical details Contents 1.0 1.0 Contents 1.10 1.100 System description System description PETREX - 1.11 1.11.01 Product overview Piping, connections, fittings

More information

Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering

Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering Maintenance The bodies of Harmer Floor Drains have a smooth polyester coating which prevents adherence of foreign

More information

RUUKKI FAÇADE SYSTEMS

RUUKKI FAÇADE SYSTEMS www.ruukki.co.uk RUUKKI FAÇADE SYSTEMS 1. General Ruukki Forma is a complete façade system in which Ruukki energy panels form an energy efficient base structure and Ruukki cladding products finalize the

More information

Cabin Specifications:

Cabin Specifications: The Luxury cabin Cabin Specifications: Price: $15,900 including GST for the basic kit Built size: Cabin = 5.85m x 4.45. Veranda = 5.85m x 2.25m. Height 2.47m/3.57 Flat packed: 5.85m x 2.25m. Height 1.5m

More information

system 8000 partitioning technical and construction data

system 8000 partitioning technical and construction data system 8000 partitioning technical and construction data System 8000 introduction System 8000 The components are designed to construct glazed partition walls with minimalist framework free from inter-panel

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008 Revisions Notes Changed note Date 1 (A) Changed template 09 / 07 / 2008 2 Changed template. Clause 12.5.4.1 hot-rolled steel added. Clause 12.5.4.2, 12.5.2.4, 12.5.3.4, 12.5.4.4, 12.5.5.4, 12.5.6.4, 12.5.7.4

More information

Trade of Sheet Metalwork. Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2

Trade of Sheet Metalwork. Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2 Trade of Sheet Metalwork Module 5: Ductwork Unit 3: 90 Radius Bend with Proprietary Flanges Phase 2 Table of Contents List of Figures... 5 List of Tables... 5 Document Release History... 6 Module 5 Ductwork...

More information

In Situ Metallography

In Situ Metallography In Situ Metallography INDEX 1. INTRODUCTION 2. APPLICATION REQUIREMENTS 3. SAMPLE PREPARATION PROCESSES 4. RESULT Field metallographic procedures are performed on location or in the field on components

More information

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description Roofing Product Data Sheet Edition 02.2015 Identification no: 02 09 01 01 201 0 120000 Version no. 04 Sarnafil S 327-12EL Polymeric membrane for roof waterproofing Product Description Sarnafil S 327-12EL

More information

HIGH PERFORMANCE PIR INSULATION

HIGH PERFORMANCE PIR INSULATION HIGH PERFORMANCE PIR INSULATION FOR RESIDENTIAL, INDUSTRIAL AND AGRICULTURAL APPLICATIONS Export Delivery Programme Lambda 0.022 from 20 mm up to 200 mm www.unilininsulation.com UNILIN, division insulation

More information

MORENDO. Rectangular sound attenuator with low installation height and tapered acoustic baffle surfaces

MORENDO. Rectangular sound attenuator with low installation height and tapered acoustic baffle surfaces Rectangular sound attenuator with low installation height and tapered acoustic baffle surfaces Quick facts Can be used everywhere where rectangular sound attenuators are used Low installation height Low

More information

DIBOND 3A COMPOSITES. The ultimate aluminum composite Material (Acm) Sales Training Presentation by 3A Composites Level 201

DIBOND 3A COMPOSITES. The ultimate aluminum composite Material (Acm) Sales Training Presentation by 3A Composites Level 201 DIBOND The ultimate aluminum composite Material (Acm) Sales Training Presentation by 3A Composites Level 201 2 0 10 USA, INC. Introduction Welcome to the Sales Training Presentation by 3A Composites In

More information

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit) Flue gas kit DN60 rigid in the duct 100193 Flue gas kit No Outlet set plastic 1 x Set 100193 39.10 (Quantities in the image differ from the set) 1003253 1001938 Spacer set * ( pieces) Top inspection opening

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19 Page 1 or 8 APPLICATION This fi re damper is intended to restrict the passage of fl ame. The standard installation requires that the

More information

Success with 2009 IECC in Arkansas Tech Tips for Builders HVAC INSTALLATION

Success with 2009 IECC in Arkansas Tech Tips for Builders HVAC INSTALLATION Success with 2009 IECC in Arkansas Tech Tips for Builders TECH TIPS: 1. Seal all duct work to drywall and/or subfloor and all HVAC penetrations in the building envelope with foam, caulk or mastic. Use

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314 CI/SfB Oct 12 (52.5) Uniclass L7314 Bailey Flow-therm Product Selector A RANGE OF QUALITY AND ROBUST RAINWATER OUTLET AND VENTILATION SYSTEMS FOR FLAT ROOFS, MANUFACTURED FROM RIGID POLYURETHANE. Bailey

More information

Pre-Fabricated Roof Curbs

Pre-Fabricated Roof Curbs TC-1, TC-2, TC-3, TC-5 Table of Contents General Information 4-5 Specifications 6-9 Assembly Instructions 10-16 Pitch Information 17 Submittal 18-21 54 years of excellence... www.thybar.com 3 Insulated

More information

Meter Connection Products: Overview

Meter Connection Products: Overview : Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature

More information

Backdraught Damper. Duct Width. Duct Height. Elevation Page 36 DESCRIPTION

Backdraught Damper. Duct Width. Duct Height. Elevation Page 36 DESCRIPTION SPECIFICATION DESCRIPTION The damper casing is formed from 3.0 mm thick sheet steel into a rigid channel section to ensure proper alignment of blades and shafts. Where circular dampers are required, additional

More information

ANDESI. Roofing sheet. Multiple choice to meet the different demand

ANDESI. Roofing sheet. Multiple choice to meet the different demand ANDESI Roofing sheet Multiple choice to meet the different demand ASA synthetic Resin Tile Width:1050mm Length : customized Thickness: 2.3-3.5mm color: customized Features of ASA synthetic Resin Tile Long

More information

Sentron Low Amp Busway

Sentron Low Amp Busway Sentron Low Amp Busway Sentron Low Amp Busway is a member of the Siemens Sentron Busway family. Sentron Low Amp Busway specifically addresses the needs of low amp power distribution applications, with

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Design and Construction Standards SECTION HYDRONIC PIPING

Design and Construction Standards SECTION HYDRONIC PIPING SECTION 15510 HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME

More information

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following: PART 1 GENERAL 1.01 SUMMARY SECTION 03460 TILT-UP PRECAST CONCRETE SANDWICH PANELS A. Work includes, but is not limited to, the following: 1. Architectural precast concrete sandwich wall panels. 2. Integral

More information

LPG CYLINDER PRODUCTION LINES

LPG CYLINDER PRODUCTION LINES LPG CYLINDER PRODUCTION LINES TURN KEY LPG CYLINDER PRODUCTION PLANT LPG Cylinder Production within the guidelines of the international standards such as EN 1442 involves several process steps starting

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 15510 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME

More information

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System TCC-1 Pipe Penetration System TCC-3 Pipe Penetration System TCC-5 Pipe Penetration System 54 years of excellence... www.thybar.com 82 Table of Contents General Information 84 Specifications 85 Assembly

More information

Aluminium Single Deflection Grilles. Model Series 5100

Aluminium Single Deflection Grilles. Model Series 5100 Aluminium Single Deflection Grilles Model Series 5100 Aluminium Single Deflection Grilles Models 51SV and 51SH Single Deflection Supply Grilles are recommended for applications requiring pattern adjustment

More information

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description January, 2009 Sarnafil TS 77-15 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics / Advantages Approval / Standards Sarnafil TS 77-15 (thickness 1.5 mm) is

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 DESCRIPTION A. Roof Curbs SECTION 23 37 00 AIR OUTLETS AND INLETS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION HANGERS AND SUPPORTS FOR PLUMBING SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MI Tube Skin Thermocouple Assembly

MI Tube Skin Thermocouple Assembly indegenised the Skin Thermocouple assemblies first time in India. Tube Skin Thermocouples manufactured by us are reliable for measurement and control of tube surface temperature in fire heaters. Accurate

More information

FABRICATION OF A NEW INDUCED DRAUGHT FAN DUCTING KILN 2

FABRICATION OF A NEW INDUCED DRAUGHT FAN DUCTING KILN 2 FABRICATION OF A NEW INDUCED DRAUGHT FAN DUCTING KILN 2 SITE INFORMATION The tenderer should, in his own interest, visit the site and familiarize with the site conditions before tendering. For any clarification,

More information

Steady-State R-Value Calculation. PS-4600 PolySteel Form

Steady-State R-Value Calculation. PS-4600 PolySteel Form Steady-State R-Value Calculation Introduction R value has been established as the primary measurement of energy efficiency in building construction. Steady state R value is the traditional method to determine

More information

PUNCH RANGE hydraulic punching machines

PUNCH RANGE hydraulic punching machines PUNCH RANGE hydraulic punching machines punch station-applications punch - double punch The Kingsland range of Hydraulic Punching machines all maximum capacity. The punching machines are available from

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 07540 - THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES A. Mechanically attached system with thermoplastic roofing membrane. B. Insulation, flat and tapered. C. Flashings. D.

More information

Highfield boats Quality Presentation. Highfield 2014 World Conference

Highfield boats Quality Presentation. Highfield 2014 World Conference Highfield boats Quality Presentation 1. Raw material qualification 1. Fabrics 2. Assemblies 3. Powder coating 4. Accessories 5. Aluminum 2. Quality control on production Fabric 1) Tensile strength test

More information

Due to a depreciating Aussie dollar and increase in local steel prices our pricing will change on October 1 st.

Due to a depreciating Aussie dollar and increase in local steel prices our pricing will change on October 1 st. The Allrounder Due to a depreciating Aussie dollar and increase in local steel prices our pricing will change on October 1 st. Cabin Specifications: Price: $8,450 including GST for the basic kit. $8,990

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300 C. ANSI/ASME

More information

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

LLOYD INDUSTRIES INC.   DAMPER INSTALLATION INSTRUCTIONS Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage. 2.

More information

GORDON-INC.COM FAX GASKETED GRIDS. CANTRELL DRUG Little Rock, AR

GORDON-INC.COM FAX GASKETED GRIDS. CANTRELL DRUG Little Rock, AR GASKETED GRIDS CANTRELL DRUG Little Rock, AR CG SYSTEM Applications for CG systems include food service, food processing, pharmaceutical, and hospital industries. Designed with a 1-1/2" face tee to support

More information

Cabin Specifications:

Cabin Specifications: The Triple Allrounder Cabin Specifications: Price: $24,500 including GST for the basic kit. Built size: 9.75m x 5. 80m. Height 2.71/2.27 Flat packed: 5. 80m x 2.25m. Height 650mm. x 3 packs for Triple

More information

CEILING & WALL SYSTEMS

CEILING & WALL SYSTEMS CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.

More information

SECTION AIR DUCT CLEANING

SECTION AIR DUCT CLEANING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

RECEIVING AND HANDLING

RECEIVING AND HANDLING FD and DFD 150X Series models are intended for installation in accordance with fire damper requirements established by: National Fire Protection Association NFPA Standard 90A BOCA National Building Codes

More information

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon, Summary Specification Re-Skinning Over Two Existing Roofs The Top Roof Being a Totally Adhered Single Ply Over a Built-Up-Roof On A Poured-in-Place Concrete Deck Using the Existing Angle Change Terminations

More information

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following: PART 1 GENERAL 1.01 SUMMARY SECTION 03460 TILT-UP PRECAST CONCRETE SANDWICH PANELS A. Work includes, but is not limited to, the following: 1. Architectural precast concrete sandwich wall panels. 2. Integral

More information

Sample Specification

Sample Specification POWERS FASTENERS Sample Specification Section 23 30 xx HVAC Ducts and Casings The intent of this Sample Specification is to illustrate the use of ICC ES Acceptance Criteria as reference standards in the

More information

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780) 9333 45 Avenue Edmonton, AB Toll Free: 1-800-272-9693 Phone: (780) 436-1930 Fax: (780) 435-4849 info@can-con.com TABLE OF CONTENTS PLASTIC FITTINGS POLYETHYLENE PIPE...- 1 - SERVICE RISERS... - 3 - TRANSITION

More information

PRODUCT BROCHURE. Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : smartemp.com

PRODUCT BROCHURE. Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : smartemp.com PRODUCT BROCHURE Linear Multistream Ceiling Diffuser LMC-AD LMC-AD : 07 smartemp.com DESCRIPTION The SMARTEMP Linear Multistream Ceiling Diffuser, type LMC-AD (figure ), is a multi-nozzle linear slot diffuser

More information