[Service Ref.] PUMY-P112VKM PUMY-P125VKM PUMY-P140VKM PUMY-P112YKM PUMY-P125YKM PUMY-P140YKM

Size: px
Start display at page:

Download "[Service Ref.] PUMY-P112VKM PUMY-P125VKM PUMY-P140VKM PUMY-P112YKM PUMY-P125YKM PUMY-P140YKM"

Transcription

1 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALO HFC utilized RA February 0 No. OCB <Outdoor unit> [Model Name] PUMY-PVKM PUMY-PVKM PUMY-PVKM PUMY-PYKM PUMY-PYKM PUMY-PYKM Salt proof model PUMY-PVKM-BS PUMY-PVKM-BS PUMY-PVKM-BS PUMY-PYKM-BS PUMY-PYKM-BS PUMY-PYKM-BS [Service Ref.] PUMY-PVKM PUMY-PVKM PUMY-PVKM PUMY-PYKM PUMY-PYKM PUMY-PYKM PUMY-PVKM-BS PUMY-PVKM-BS PUMY-PVKM-BS PUMY-PYKM-BS PUMY-PYKM-BS PUMY-PYKM-BS Note: ROHS compliant products have <> mark on spec name plate. CONTENTS. PARTS LIST.... OPTIONAL PARTS... Back cover SERVICE MANUAL (OCH) Model name indication OUTDOOR UNIT

2 PARTS LIST -. STRUCTURAL PARTS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS 0 No. PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS Q'ty/unit R0 E0 SIDE PANEL(L) R0 E0 ICE UARD R0 E WIRE RILLE R0 E0 HANDLE(FRONT) R0 E FRONT PANEL R0 E BASE ASSY SEPARATOR TW E COVER PANEL(FRONT) 0 R0 E COVER PANEL(REAR) R0 E0 HANDLE(REAR) R0 E SIDE PANEL(R) TW E0 SERVICE PANEL LABEL(CITY MULTI) (BHT0H0) VALVE BED (BK00C0) R0 E0 REAR UARD R0 E TOP PANEL R0 E 0 MOTOR SUPPORT OCB Parts Name F. ST SCREW Specification (x) Remarks (Drawing No.) (DFH) (BK00B) Wiring Diagram Symbol

3 Y-PYKM- PARTS LIST STRUCTURAL PARTS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS 0 PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS SIDE PANEL(L) ICE UARD R0 E WIRE RILLE R0 E0 HANDLE(FRONT) R0 E FRONT PANEL R0 E BASE ASSY SEPARATOR TW E COVER PANEL(FRONT) 0 R0 E COVER PANEL(REAR) No. PUMY-PYKM Q'ty/unit R0 E0 R0 E0 Parts Name F. ST SCREW Specification (X) Remarks (Drawing No.) (DFH) (BK00B) R0 E0 HANDLE(REAR) TW E SIDE PANEL(R) TW E0 SERVICE PANEL LABEL(CITY MULTI) (BHT0H0) VALVE BED (BK00C0) R0 E0 REAR UARD R0 E TOP PANEL R0 E 0 MOTOR SUPPORT OCB Wiring Diagram Symbol

4 PARTS LIST PUMY-PVKM- -. FUNCTIONAL PARTS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS OCB

5 PARTS LIST Part numbers that are circled are not shown in the figure. Q'ty/unit No. Parts Name Specification PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS PUMY-PVKM PUMY-PVKM-BS Remarks (Drawing No.) Wiring Diagram Symbol R0 E FAN MOTOR MF,MF R0 E0 0 NUT R0 E PROPELLER FAN R0 E CHARE PLU TW E0 0 HIH PRESSURE SENSOR ASSY HS T 0 COMPRESSOR ANBFNHMT Including RUBBERMOUNT MC R0 E STOP VALVE /F / R0 E BALL VALVE /F / R0 E0 0 THERMISTOR Compressor TH 0 R0 E ACCUMULATOR R0 H 0 THERMISTOR Hic Pipe TH R0 E CHARE PLU R0 H 0 THERMISTOR Suction Pipe, Ambient Combined Port TH,TH TW E SOLENOID COIL S R0 E WAY VALVE R0 E0 0 LOW PRESSURE SENSOR LS R0 E0 0 HIH PRESSURE SWITCH H R0 E SOLENOID VALVE Bypass Valve (SV) TW E SOLENOID COIL SV 0 R0 H LEV COIL UKV type WHITE LEV-A TW E LEV-A ASSY Including LEV COIL R0 H LEV COIL CAM type RED LEV-B TW E LEV-B ASSY Including LEV COIL and STOP VALVE R0 H 0 THERMISTOR Outdoor Liquid Pipe TH TW E HEAT EXCHANER TW E0 0 OIL SEPARATOR TW A00 CT ASSY R0 A 0 COMP FELT(TOP) R0 A 0 COMP FELT(BODY) 0 R0 AM0 0 CONTROLLER CIRCUIT BOARD MULTI.B. TW A TERMINAL BLOCK P(L,N,;) TB TW E TERMINAL BLOCK P(B,B) TBB R0 E TERMINAL BLOCK P(M,M,S) TB,TB TW E0 REACTOR DCL R0 E0 MAIN SMOOTHIN CAPACITOR CB R0 A POWER CIRCUIT BOARD P.B. R0 A0 HEAT SINK ELECTRICAL PARTS BOX (BK00L0) R0 E0 M-NET POWER CIRCUIT BOARD M-NET P.B. R0 E0 FUSE 0A 0V FUSE,FUSE R0 0L FUSE HOLDER R0 E0 0 LEAD ASSY COMP R0 E FUSE.A 0V F,F OCB

6 PARTS LIST PUMY-PYKM- FUNCTIONAL PARTS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS OCB

7 PARTS LIST Parts numbers that are circled are not shown in the figure. Q'ty/unit No. Parts Name Specification PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS PUMY-PYKM PUMY-PYKM-BS Remarks (Drawing No.) Wiring Diagram Symbol R0 E FAN MOTOR MF,MF R0 E0 0 NUT R0 E PROPELLER FAN R0 E REACTOR DCL R0 E CHARE PLU TW E0 0 HIH PRESSURE SENSOR ASSY HS T 0 COMPRESSOR ANBFNMT Including RUBBERMOUNT MC R0 E STOP VALVE /F / R0 E BALL VALVE /F / 0 R0 E ACCUMULATOR R0 E0 0 THERMISTOR Compressor TH R0 H 0 THERMISTOR Hic Pipe TH R0 E CHARE PLU R0 H 0 THERMISTOR Suction Pipe, Ambient Combined Port TH,TH TW E SOLENOID COIL S R0 E WAY VALVE R0 E0 0 LOW PRESSURE SENSOR LS R0 E0 0 HIH PRESSURE SWITCH H R0 E SOLENOID VALVE Bypass Valve(SV) 0 TW E SOLENOID COIL SV R0 H LEV COIL UKV type WHITE LEV-A TW E LEV-A ASSY Including LEV COIL R0 H LEV COIL CAM type RED LEV-B TW E LEV-B ASSY Including LEV COIL and STOP VALVE R0 H 0 THERMISTOR Outdoor Liquid Pipe TH TW E HEAT EXCHANER TW E0 0 OIL SEPARATOR TW A00 CT ASSY R0 A 0 COMP FELT(TOP) 0 R0 A 0 COMP FELT(BODY) TW E0 TERMINAL BLOCK P(L,L,L,N,;) TB TW E TERMINAL BLOCK P(B,B) TBB R0 E TERMINAL BLOCK P(M,M,S) TB,TB R0 AM0 0 CONTROLLER CIRCUIT BOARD MULTI.B. R0 E0 M-NET POWER CIRCUIT BOARD M-NET P.B. R0 E REACTOR ACL R0 A HEAT SINK R0 E0 RESISTOR RS ELECTRICAL PARTS BOX (BK00C0) TW A0 POWER CIRCUIT BOARD P.B. TW E NOISE FILTER CIRCUIT BOARD N.F. R0 H 0 THERMISTOR Heat Sink TH R0 E0 FUSE 0A 0V FUSE,FUSE R0 0L FUSE HOLDER R0 E 0 LEAD ASSY COMP R0 E FUSE.A 0V F,F OCB

8 OPTIONAL PARTS DRAIN SOCKET AIR OUTLET UIDE Note: Need pieces. AIR UIDE Note: Need pieces. DRAIN PAN PAC-SDS-E PAC-SHS-E PAC-SHA-E PAC-SHDP-E BRANCH PIPE (Joint) CMY-Y--E CMY-Y--E CMY-Y--E NUMBER OF BRANCHIN POINTS JOINT PIPE (Unit EXtension pipe) PAC-SRJ-E ([. [.) PAC-SRJ-E ([. [.0) Base Heater PAC-SJ0BH-E CONNECTION KIT PAC-LVM-J HEAD OFFICE : TOKYO BLD., --, MARUNOUCHI, CHIYODA-KU, TOKYO 00-0, JAPAN CCopyright 0 MITSUBISHI ELECTRIC CORPORATION Distributed in Feb. 0 No. OCB Made in Japan New publication, effective Feb. 0 Specifications are subject to change without notice.

PARTS CATALOG R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December No.OCB415 REVISED EDITION-F

PARTS CATALOG R410A SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December No.OCB415 REVISED EDITION-F SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALO Outdoor unit [Model names] PUHZ-P00VHA PUHZ-PVHA PUHZ-P0VHA PUHZ-P00VHA PUHZ-PVHA PUHZ-P0VHA PUHZ-P00VHA PUHZ-P00YHA PUHZ-P00YHA PUHZ-PYHA PUHZ-P0YHA

More information

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA SPLIT-TYPE AIR CONDITIONERS Revision F: MUZ-GE//5, MUZ-GE//5NAH and MUY-GE//5 have been added. Please void OBB549 REVISED EDITION-E. OUTDOOR UNIT PARTS CATALOG No. OBB549 REVISED EDITION-F Models MUZ-GENA

More information

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used

More information

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models : ROOM AIR CONDITIONER AK SERIES (50Hz) Models : AKY9FBSSW AKY9UBSSW CONTENTS SPECIFICATIONS.......................... CIRCUIT DIAGRAM........................ MICROCOMPUTER CONTROL CIRCUIT...... DISASSEMBLY

More information

Air Conditioners. Technical Data. Pair application EEDEN RXS-J

Air Conditioners. Technical Data. Pair application EEDEN RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Performance Comparison of Air-source Heat Pumps Using Economizer Vapor

More information

SERVICE PARTS LIST DEEP CUT BANDSAW D51C BULLETIN NO CATALOG NO SEE PAGE 3 FOR FASTENER TORQUE CHART

SERVICE PARTS LIST DEEP CUT BANDSAW D51C BULLETIN NO CATALOG NO SEE PAGE 3 FOR FASTENER TORQUE CHART = Part number change from previous service parts list. SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS DEEP CUT BANDSAW CATALOG NO. 232-20 SERVICE PARTS LIST STARTING SERIAL NO. D5C REVISED BULLETIN

More information

SURFACE TEMPERATURE SENSORS

SURFACE TEMPERATURE SENSORS SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such

More information

MODELS PH PH PH

MODELS PH PH PH WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 0 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS MPA, MPB and MLA MULTI-ZONE OUTDOOR UNITS MULTI-ZONE MINI-SPLIT OUTDOOR UNITS (08/0V) -- 079-0 0/0 Supersedes 079-0 Table of Contents

More information

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump

More information

BUSH HOG LAND MAINTENANCE REPAIR PARTS MANUAL MODELS: HS1736B, HS1742B, HS1836B, HS1842B, HS2036K, HS2042K HOME SERIES ZERO TURN MOWER SECTION: 85

BUSH HOG LAND MAINTENANCE REPAIR PARTS MANUAL MODELS: HS1736B, HS1742B, HS1836B, HS1842B, HS2036K, HS2042K HOME SERIES ZERO TURN MOWER SECTION: 85 BUSH HOG LAND MAINTENANCE REPAIR S MANUAL MODELS: HSB, HSB, HSB, HSB, HS0K, HS0K HOME SERIES ZERO TURN MOWER SECTION: 0 Griffin Ave. Selma, AL 0 () -00 Parts Ordering -00-0- Fax -00-- www.bushhog.com OCTOBER,00

More information

UFL Micro Biogas CHPs

UFL Micro Biogas CHPs UFL Micro Biogas CHPs The UFL Micro Biogas CHPs are based on the highly durable Petter industrial diesel engine. Low cost replacement parts are available worldwide. This range of micro biogas CHPs has

More information

GMV Super Star. Part List

GMV Super Star. Part List GMV Super Star Part List 25 Table of Contents Part List 25 Magazine... 28 Target Retainer... 30 Throwing Table... 31 Main Frame... 32 Turntable... 33 Base... 34 Elevator... 35 Throwing Arm... 36 Motor...

More information

FACTORY PARTS CATALOG MICROWAVE MICROWAVE FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP

FACTORY PARTS CATALOG MICROWAVE MICROWAVE FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP START FACTORY PARTS CATALOG MICROWAVE PRODUCT NO. BASE MODEL NO. COLOR MARKET FMT144G1B1 FMT144G1W1 FMT148G1B1 FMT148G1W1 FMT148G1T1 FMT148GPB1 FMT144G1B2 FMT144G1W2 FMT148G1B2 FMT148G1W2 FMT148G1T2 FMT148GPB2

More information

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL : 514.337.4415 LAVAL (QUEBEC) FAX : 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

Flooded Type Water-Cooled Chillers. R134a

Flooded Type Water-Cooled Chillers. R134a Flooded Type WaterCooled Chillers The HighEfficiency WaterCooled Flooded Chillers The New WaterCooled Flooded chiller with improved efficiency and functionality by incorporating several advanced technology

More information

WATER CHILLER COOLING SOLUTIONS

WATER CHILLER COOLING SOLUTIONS WATER CHILLER COOLING SOLUTIONS WWW.LABTECHSRL.COM COOLING SOLUTIONS BY LABTECH Even if water is one of the most precious and scarce resources, it is still largely used as coolant in many laboratories.

More information

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier of 5 Page Car SingleVario 06 Stack Parker 06 50 for vehicle up to 5.00 m = 6 long (50 for vehicle up to 5.0 m 7 long) Depending on location, design also as wind protection. Product Data CONFORMITY 06/06/G63

More information

CO2 in Vending Machine

CO2 in Vending Machine CO2 in Vending Machine CO2 SANYO Electric Co., Ltd. Commercial Solutions Company Daiki Shiomi Outline Contents 1. Company Profile 2. CO2 Compressor / Refrigeration System 3. CO2 System Performance 4. VM

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com VERSION Z MODELS 300500 SUMP PUMPS Your pump

More information

Product Specifications

Product Specifications Product Specifications Models Unit Cooling Capacity kw 0.30~2.63~3.80 0.30~3.51~4.04 Btu/h. 1,023~9,000~12,966 1,023~12,000~13,785 Heating Capacity kw 0.30~3.22~6.50 0.30~3.98~6.50 Btu/h. 1,023~11,000~20,472

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01 Installation plan Washer-extractor PW 6107 EL en - GB 10.11 M.-Nr. 09 270 450 / 01 M.-Nr. 09 270 450 / 01 2 Technical Datasheet Washer-extractor: Heating: PW 6107 Electric (EL) Legend: Solid circle

More information

Reliable, low-maintenance process heating

Reliable, low-maintenance process heating Reliable, low-maintenance process heating MPERATURE CONTROL UNITS Water and Oil up to 400 C WE MAKE IT WORK CONNTS pages Over nearly 30 years, ICS Cool Energy has been delivering erature control solutions

More information

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons DVPTC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons Contents Air Handler Nomenclature...2 Heater Kit Nomenclature...2 Product Specifications...3

More information

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems Energieeffizient, Energy efficient, kompakt compact, und and variantenreich versatile GLAC0524- - 1204BD2 Luftgekühlte Air cooled Kaltwassererzeuger Chiller Data Daten && Facts Fakten Lufttechnik GEA Heat

More information

RDI Systems. Scroll Series Refrigeration System. Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models

RDI Systems. Scroll Series Refrigeration System. Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models RDI Systems Scroll Series Refrigeration System Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models PC Refrigeration Systems The RDI PC Refrigeration system includes an RDI condensing

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

SECTION COOLING TOWER

SECTION COOLING TOWER PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue

More information

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24 VI PARTS LIST ORDERING PARTS Parts may be ordered by part number by calling Keating at 1-800-KEATING or your service company. You may also order online at Keating s part store, www.keatingofchicago.com.

More information

SECTION ROTARY SCREW WATER CHILLERS

SECTION ROTARY SCREW WATER CHILLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Unitary Air Conditioner Field Performance

Unitary Air Conditioner Field Performance Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2004 Unitary Air Conditioner Field Performance Todd M. Rossi Field Diagnostic

More information

RT8725. Single-Phase BLDC Fan Driver IC. Features. General Description. Applications

RT8725. Single-Phase BLDC Fan Driver IC. Features. General Description. Applications RT8725 Single-Phase BLDC Fan Driver IC General Description The RT8725 is a single-phase driver IC for fan motors. Rotation speed is controlled by input signal. The RT8725 provides several protection features

More information

Introduction of the latest Technology of Energy Conservation

Introduction of the latest Technology of Energy Conservation Introduction of the latest Technology of Energy Conservation --- To blue chip companies due to effective energy utilization --- September 15, 2015 Fuji Electric Co., Ltd. 1 Trends and prospects of the

More information

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs) 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons Product Data Carrier s air-cooled air conditioning split systems: S provide a logical solution for commercial needs S have

More information

Charmilles. Description. Air filter for generator. 373x497x20mm. Air filter for generator. 210x275x20mm. Air filter for generator.

Charmilles. Description. Air filter for generator. 373x497x20mm. Air filter for generator. 210x275x20mm. Air filter for generator. Air filter 100992004 Air filter for generator 373x497x20mm 108732900 Air filter for generator 210x275x20mm RFI 500. 510 108626140 Air filter for generator 315x450x20mm RFI 040. 300. 310. 500. 510 108626260

More information

Operations Manual. For Research Use Only. PH: EM: WEB:

Operations Manual. For Research Use Only. PH: EM: WEB: Operations Manual For Research Use Only PH: 908-769-5555 EM: info@benchmarkscientific.com WEB: www.benchmarkscientific.com Thank you for choosing the BioClave Benchtop Sterilizer. Prior to operating this

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

TYPE r PARTS LIST

TYPE r PARTS LIST /0/0 09 9 -- /0/0 TYPE --- 0 9 All repairs, adjustments and maintenance not described in the Operator s Manual must be performed by qualified service personnel. MAC CAT 9 9 0 0 0 9 it--oil Check Valve

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two Marine/Industrial Single Package Design Series One, Beginning Serial Number C96741 & Design Series Two 62-10404 -01 PARTS LIST Service Parts List SINGLE PACKAGE COOLING UNIT Design Series One, Beginning

More information

OPO-SHORT Installation Instructions Manual Version

OPO-SHORT Installation Instructions Manual Version 10200 South Kedzie Avenue Evergreen Park, IL 60805 800.499.0400 708.499.0400 Fax 708.499.4620 OPO-SHORT Installation Instructions Manual Version OPO-1S, OPO-3S, OPO-4S PreSell Main Board (shown as Standard

More information

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code) ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code) Versatile, high quality, circuit board mounting miniature socket Specially designed

More information

Air Cooled Packaged Air Conditioning

Air Cooled Packaged Air Conditioning Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated

More information

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02 Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380

More information

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01 Installation recommendations Washer-extractor PW 6080 EL AV/LP en - GB 11.09 Mat. no. 07 780 680 / 01 It is essential to read the operating and installation instructions before installing, commissioning

More information

Motor-driven Diaphragm Metering Pump

Motor-driven Diaphragm Metering Pump Motor-driven Diaphragm Metering Pump OPEN Easy, Tough and Safe This stylishly designed safe TACMINA metering pump is easy-to-use and user-friendly developed with excellent utility, functionality and durability.

More information

BLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES

BLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES BLOWER COILS 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Grooved copper tubing Lanced sine--wave aluminum fin Fully wettable

More information

Danfoss and Controls for CO2

Danfoss and Controls for CO2 Danfoss and Controls for CO2 CO 2 www.danfoss.com/foodretail Department (slide master) Optional text Date 1 Controllers for various CO2 applications Some examples of Danfoss controllers suited for CO2:

More information

AIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology

AIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology AIR CONDTIONERS XC16 ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology E N G I N E E R I N G D ATA Bulletin 210465 October 2009 Supersedes March 2009 SEER up to 17.20 2 to 5 Tons Cooling

More information

HEATMAX. Mechanical Installation and Commissioning Instructions HEATMAX

HEATMAX. Mechanical Installation and Commissioning Instructions HEATMAX HEATMAX Mechanical Installation and Commissioning Instructions HEATMAX 1. General Safety Information 2. General Product Information 3. Installation 4. Commissioning 5. Maintenance -----------------------------------------

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

Fiberglass Cooling Towers

Fiberglass Cooling Towers Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality

More information

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed

More information

SEMPEO SQA Unit Code FP3G 04 Forming and assembling electrical cable enclosure and support systems

SEMPEO SQA Unit Code FP3G 04 Forming and assembling electrical cable enclosure and support systems Forming and assembling electrical cable enclosure and support Overview This standard covers a broad range of basic competences that you need to form and assemble electrical cable enclosure and support

More information

Your partner for the right solution

Your partner for the right solution Your partner for the right solution Project engineering of power stations Environment protection in energy sector Equipment supplying Supervision of installation of the equipment supplied Commissioning

More information

GA /GA VSD

GA /GA VSD GA 30 + -90/GA 37-90 VSD 30-90 kw/40-125 hp Oil-injected Rotary Screw Compressors Leading Performance, Total Reliability Total capability, total responsibility Right at the heart of your business, Atlas

More information

For Safe and Delicious Water

For Safe and Delicious Water RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and

More information

General Specification

General Specification General Specifications TB600G Laser Turbidity Meter GS 127A1 General With the recent development in membrane filtration technologies, organic filters have come into practical use as a highperformance treatment

More information

BLOWER COILS COMMERCIAL

BLOWER COILS COMMERCIAL BLOWER COILS COMMERCIAL 2 THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Listed By Underwriters Laboratories Grooved copper tubing

More information

Geothermal Comfort Systems

Geothermal Comfort Systems Frequently Asked Questions Q: How efficient are geothermal heat pump systems? A: Actual efficiencies will depend on a number of factors, but generally speaking a geothermal heat pump can be three to five

More information

ANALYZER MODEL BECKMAN COULTER CX INCLUDES CE AND DELTA REPLACEMENT & CONSUMABLE PARTS LIST

ANALYZER MODEL BECKMAN COULTER CX INCLUDES CE AND DELTA REPLACEMENT & CONSUMABLE PARTS LIST ANALYZER MODEL BECKMAN COULTER CX INCLUDES CE AND DELTA REPLACEMENT & CONSUMABLE PARTS LIST FOR NEEDED SERVICE PARTS AND SUPPLIES NOT SHOWN PLEASE CALL PART NUMBER DESCRIPTION 010177 BI O RING, DETECTOR

More information

Online Gas Analyzer / Monitor

Online Gas Analyzer / Monitor Sheet No. 1 of 9 CH4 H2 SOX NOX NH3 CO2 HF HCL HCN CO O2 Providing the latest in Combustion Gas & Emission Analyzers for Boiler, Engine, Furnace, and other applications. Sheet No. 2 of 9 Vasthi OMGA 8000

More information

Fish Tank Project Introduction. EAS 199B Portland State University Mechanical and Materials Engineering

Fish Tank Project Introduction. EAS 199B Portland State University Mechanical and Materials Engineering Fish Tank Project Introduction EAS 199B Portland State University Mechanical and Materials Engineering Learning Objec.ves for these Slides A9er this presenta.on you should be able to Explain the scope

More information

F64G - Olympian Plus Plug-In System General purpose filter

F64G - Olympian Plus Plug-In System General purpose filter > > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:

More information

Fish Tank Project Overview ME 121 Mechanical Engineering Freshman Curriculum Portland State University

Fish Tank Project Overview ME 121 Mechanical Engineering Freshman Curriculum Portland State University Fish Tank Project Overview ME 121 Mechanical Engineering Freshman Curriculum Portland State University The fish tank is a small PVC container of water used as a physical model of a saltwater aquarium.

More information

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw Atlas Copco High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw Proven reliability at the lowest operational cost By combining the right mix of innovation, high-tech

More information

Return Line Filter RFM

Return Line Filter RFM Return Line Filter RFM Flow rates up to 85 l/min Pressure range up to 1 bar Material: Aluminium/Steel/Synthetic material Return line filters type RFM are designed to be mounted on tank tops to filter out

More information

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO Milk Pre-Cooler Plumbing Considerations ATCP 65, Wisconsin Administrative Code and the 2015 PMO Protection of Potable Water Supply Protecting potable water supply (well) Raw milk and chemical cleaning

More information

B. ASHRAE 1991 HVAC Applications Handbook: Chapter 34--Testing, Adjusting and Balancing.

B. ASHRAE 1991 HVAC Applications Handbook: Chapter 34--Testing, Adjusting and Balancing. PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 230593 TESTING, ADJUSTING, AND BALANCING A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SOLAR WATER PUMP KIT MODEL: SIS-10HP

SOLAR WATER PUMP KIT MODEL: SIS-10HP SOLAR WATER PUMP KIT MODEL: SIS-10HP Model: SIS -10HP Pump Size: 6 Capacity in HP: 10 PV Size in kw: 10 Water head range 14-53 meter Water quantity range 20000-78000 liter per hour Quantity Description

More information

Casing Gas Recovery Unit

Casing Gas Recovery Unit Standard Features RotorComp NK60 Twin Screw Compressor 25 HP Hydraulic Or Electric Motor 8 x 48 Inlet Scrubber c/w Double Diaphragm Pump 2-4 x 42 Activated Alumina Regenerative Drying Vessels Oil/Gas Discharge

More information

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

PLUS TEMPERATURE CONTROL SYSTEMS FOR THE CHEMICAL, PHARMACEUTICAL AND PLASTICS INDUSTRIES

PLUS TEMPERATURE CONTROL SYSTEMS FOR THE CHEMICAL, PHARMACEUTICAL AND PLASTICS INDUSTRIES PLUS TEMPERATURE CONTROL SYSTEMS FOR THE CHEMICAL, PHARMACEUTICAL AND PLASTICS INDUSTRIES Tailor made for your process, providing accurate temperature control up to 400 C 1 WE MAKE IT WORK Over nearly

More information

Design and development of a residential gas-fired heat pump

Design and development of a residential gas-fired heat pump Design and development of a residential gas-fired heat pump Edward A Vineyard a*, Ahmad Abu-Heiba a, Isaac Mahderekal b a Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN, 37831, USA

More information

NaturaLINE. In making history, we ve created the future.

NaturaLINE. In making history, we ve created the future. NaturaLINE In making history, we ve created the future. The Natural One For container shipping, CO 2 is the only refrigerant that meets all of the following criteria: Natural Leadership Carrier has been

More information

DRAWING NUMBER REVISION TITLE PAGE G Identification and Traceability 1 of 11

DRAWING NUMBER REVISION TITLE PAGE G Identification and Traceability 1 of 11 90-2000-7.5.3 G Identification and Traceability 1 of 11 WRITTEN BY: DATE: APPROVED BY: DATE: J. Caruso J. Porter PRODUCT RESOURCES NEWBURYPORT, MA USA NOTICE: THIS DOCUMENT IS PROPRIETARY AND ITS CONTENTS

More information

AQUAROBIC MINI-PLANT TM

AQUAROBIC MINI-PLANT TM AQUAROBIC MINI-PLANT TM Process Description The Mini-Plant TM is a Sequential Batch Reactor (SBR) system, controlled by a factory set programmer that regulates aeration, settling, and pump functions. The

More information

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw One Stage Heavy Oil Burners RIELLO 40 N SERIES The Riello 40 N series of one stage heavy oil burners, is a complete range of products developed to respond to any request for the use of heavy oil in heating

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Z Series (Z-Foil) Vishay Foil Resistors.

Z Series (Z-Foil) Vishay Foil Resistors. Z Series (Z-Foil) Ultra High Precision Z-Foil Resistor with TCR of ± 0.05 ppm/ C, Tolerance of ± 0.005 % (50 ppm), Load Life Stability of ± 0.005 %, ESD Immunity up to 25 kv and Thermal EMF of 0.05 µv/

More information

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address Type of product RO400 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 19 RO400 USER'S MANUAL 01 Introduction of RO400 02 What is Reverse Osmosis 03 Components& Selections 04 Cartridge filters

More information

BINAR Quick-Lift System

BINAR Quick-Lift System BINAR Quick-Lift System Install and Training Original Document - July 1, 2015 1 What to expect The installation, set-up, and training process takes an average of 1.5 days (12 hours) per unit. On the first

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

Thermal-Tab and Thermal-Ribbon Sensors

Thermal-Tab and Thermal-Ribbon Sensors Thermal-Tab and Thermal-Ribbon Sensors Install these compact sensors anywhere for accurate point sensing and fast response. All Thermal-Tab modules use a thin-film RTD element. All Thermal-Ribbon models

More information

Nilan VPL Active heat recovery and cooling (air/air)

Nilan VPL Active heat recovery and cooling (air/air) M a r k e t l e a d i n g c o m m e r c i a l a n d d o m e s t i c v e n t i l at i o n w i t h h e at r e c o v e r y Nilan 31-125 Active heat recovery and cooling (air/air) Nilan 31-125 Commercial ventilation

More information

Managing Product Development using Teamcenter Environment at Mercury Marine

Managing Product Development using Teamcenter Environment at Mercury Marine Managing Product Development using Teamcenter Environment at Mercury Marine Bala Shetty Technical Lead Engineer: CAD,CAM and PLM Systems balakrishna_shetty@mercmarine.com http://www.mercuryplm.com About

More information

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING 22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE NATURALLY CONTROL CLIMATE AND COST Wherever you live, the temperature beneath your home remains

More information

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer. Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09262 the environmentally sound refrigerant This product has been designed and manufactured

More information

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva Parallel installation quick start Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva UK ENGLISH 3 2 Daker DK 4.5-10 kva Index Introduction 2 1 Important Safety Instructions 2 2 Parallel

More information

Buffer Storage Systems from ENERPIPE. Flexible, economical and optimally designed

Buffer Storage Systems from ENERPIPE. Flexible, economical and optimally designed Minimizing Heat Losses Buffer Storage Systems from Flexible, economical and optimally designed DECENTRALIZED buffer storage systems of for a more efficient heat use To operate a local heating supply economically,

More information

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting

More information