ORGANISATION INTERNATIONALE

Size: px
Start display at page:

Download "ORGANISATION INTERNATIONALE"

Transcription

1 ORGANISATION INTERNATIONALE DE METROLOGIE LEGALE DENSITY MEASUREMENT Guidance for Inspectors March 1987 BUREAU INTERNATIONAL DE METROLOGIE LEGALE 11, Rue Turgot PARIS

2 DENSITY MEASUREMENT This brochure is an adapted translation of a document issued by the prepackage control department of the Dutch metrology service, authors J.A. Dalm and P. Hogervorst. Though it is mainly intended as a guide for inspectors and technicians doing prepackage control the methods and calculations described follow such rigourous lines that the brochure may also be useful for other industrial and laboratory applications. We thank the Dutch metrology service for its collaboration as well as Mr Degavre of the Belgian metrology service for his assistance in the translation. BIML BUREAU INTERNATIONAL de METROLOGIE LEGALE 11, rue Turgot PARIS - France March 1987

3 CONTENTS page 1. Introduction Units of measurement Possible sources of error Methods of density measurement Fields of application of the methods... 6 Appendix 1. Pycnometer Plunger (gamma sphere) Line marked bottle Container filled with water to its edge Hydrometer Portable electronic densimeter Electronic densimeter for laboratory use Hydrostatic balance (Mohr s balance) Plunger method for putties TABLE - Density of air free water as a function of temperature

4 1. INTRODUCTION When the content of prepackages is expressed in terms of volume but verified by weighing it is also necessary to measure the density of the product contained. It seems in practice that methods for measuring density are frequently not well understood so that significant systematic errors occur. This brochure does not include all the existing methods for density measurement but describes those most currently used and their applications. 2. UNITS of MEASUREMENT 2.1. Volume The SI unit for volume is the cubic metre, symbol m 3. In chemical laboratories and retail transactions the commonly used unit is the litre, symbol l or L. The 12th General Conference of Weights and Measures decided in 1964 to abolish an earlier definition of the litre and to define. 1 litre - 1 dm 3 exactly. Thus 1000 litres = 1 m 3 1 millilitre = 1 cm 3. The units decilitre (dl) and centilitre (cl) are by tradition admitted as legal units in a certain number of countries. With a view of avoiding their confusion with the cubic decimetre and the cubic centimetre respectively, their use in industry and science is not recommended by inter-ternational standards organizations. The millilitre (symbol ml or ml) is, however, commonly used in laboratories and in the calculations in this brochure Density Density is defined as the ratio of the mass of the product (i.e. as if it was weighed in vacuum) to its volume. The coherent SI unit for density is kg/m 3 and should normally be used for reporting density values of products. As the measurements of mass in this brochure are in grammes (g) and volume in millilitres (ml), the formulas and calculations exceptionally use the unit g/ml (which should not be confused with the unit for concentration) 1 g/ml = 1 g/cm 3 = 1000 kg/m 3 In order to avoid mistakes the units have been repeated for each formula where density values have been introduced, - 1 -

5 3. POSSIBLE SOURCES OF ERROR IN DENSITY MEASUREMENTS By the term "error" we mean the difference between the density resulting from the measurement and the true density. In general these errors originate from the following causes: a) Temperature difference if the density measurement is made at another temperature than 20 C and no correction to 20 C is applied b) Use of unsuitable measuring means c) Buoyancy effect in the measurement of mass d) Inappropriate sampling. THERE ARE ALWAYS REASONS TO TRY TO REACH THE BEST ACCURACY Temperature The national regulations usually prescribe that the true content of prepackages declared in units of volume shall be stated for the temperature of 20 C except for frozen or deep frozen products for which the content shall be declared for the temperature of sale, i.e. generally - 5 C and -18 C respectively. The measurement may possibly be done at a different temperature than 20 C but this requires knowledge of the volume expansion coefficient of the product concerned. where In this case the conversion may be done using the following formula: ρ = ρ t [1 + γ(t - 20)] ρ = density of the product at 20 C ρ t = density of the product at t C γ = volume expansion coefficient of the product. The temperature at the density measurement should anyway not depart too much from 20 C as the coefficient of volume expansion may not be known with sufficient accuracy. In general, no correction is applied if the temperature does not deviate from 20 C by more than ± 0.5 C. A lower temperature leads to a higher estimate of the density of the product which, if the correction is disregarded, is to the disadvantage of the filler (producer)

6 3.2. Choice of means and methods of measurement cases: The means and methods are likely to be unsuitable in the following A) Method not suitable for the type of product. Example: Use of a plunger in products with very high viscosity. B) Means of measurement technically unsuitable (not sufficiently rigid or having other defects). Example: Poorly fitting stopper or lid of a pycnometer leading to bad reproducibility. C) Use of weighing instruments which are not sufficiently accurate compared to the other means of measurement. Example: Use of a 50 ml pycnometer with a weighing instrument having scale intervals of 1 g. D) Calibration not sufficiently accurate. Example: Use of the nominal (marked) value of a 100 ml pycnometer when the exact value is ml Buoyancy effect in mass measurements When the volume of a product is determined by measurement of mass and density it is necessary to take into account the effect of air buoyancy. This effect follows the principle of Archimedes which says that a body immersed in a fluid (gas or liquid) is submitted to a vertical upthrust equal to the weight of the displaced fluid. According to the law of equilibrium of forces the indication of a weighing instrument depends on this upthrust and the mass is consequently in most cases slightly higher than the value indicated which is a function of the volumes or mean densities of both the product and the weights used for the weighing, or for the pre-adjustment of the weighing instrument. It is not necessary to account for this difference in commercial transactions for which the result indicated by the weighing instrument is considered exact by convention (see OIML RI 33 - Result of weighing in air) However, it is important to take the buoyancy in air into account when making density measurements with high accuracy. In practice the computations are made using as density for standard weights the value ρ n = 8 g/ml and as a mean density of air ρ 1 = g/ml - 3 -

7 Using these two values one may deduce the following expression: density of product mass = apparent mass x g/ml density of product The computations in the methods of measurement described in the annexes all take into account the effect of buoyancy. (*) Note concerning the development of air buoyancy formulas. The weighing instrument, generally an electronic balance, is assumed to have been adjusted at its place of use with standard weights (mass= m n ). If the product weighed (mass = m) has a density (ρ ) which is different from that (ρ n ) of the standard weight, we have m m n mg ρ1 g = m n g' ρ1 ' g' ρ ρ n where g and g are the accelerations due to gravity which act on the product and on the standard weights respectively. For an electronic balance which is adjusted at the site of use g = g. One also assumes that the density of air is the same, i.e. ρ 1 = ρ 1. With the values ρ 1 = g/ml and ρ n = 8 g/ml one obtains m n ρ m = ρ In practice m n represents the indication of the balance (or apparent mass) corrected for possible systematic errors which may have occured after its adjustment. For a product with ρ = 8 g/ml the mass m is equal to m n n and no correction is required. In case the true volume V is known one obtains by substituting ρv for m. m ρ = n g/ml V This latter expression is currently used for measurements with pycnometers. To calculate very exactly the volume of a product from the result of weighings in air and a known density one has finally to use the following formula M V = ml ρ where, as previously, the mass indicated by the balance M is expressed in grammes and ρ in g/ml

8 3.4. Other sources of error Inclusion of air One has to distinguish between two cases: a) Inclusion of air in the product itself and thus also in the sample. For a certain number of products air is introduced by its own during various phases of production without possibility to escape; it is thus already present in these products during the sampling. b) Introduction of air into the sample during the sampling procedure. Air introduced during the sampling may in some cases escape rapidly from the product and in other cases disappear only very slowly. It may thus take hours or days before the product is fully free of air (example: shampoos). There are also cases where air remains continually in the product after its introduction, e.g. in putties. Non transparent liquids, where the presence of air is unperceptible make measurements still more uncertain. Guidance: - Density measurements shall only be made after having eliminated the air from the sample. Pouring and mixing of liquids should therefore be done smothly and with great care - For certain products air is introduced in the manufacturing process and is considered as a inseparable part of the product - If there is evidence that air is introduced after the filling procedure and that this phenomenon is only temporary (the air will not remain In the final product), it may be possible to take the samples from the vats or elsewhere before the filling Sedimentation or separation of constituents Products composed of several constituents of differing densities may have a tendency to settle non-homogeneously. The following cases are examples of causes of error in sampling: a) The sample is taken from a non-homogenous phase. The density of the sample is then different from the mean density and it is possible that the density decreases during continued filling of the prepackages. It is necessary to take this into account during sampling and - either choose a sample elsewhere in the production line, or - take a greater number of samples. b) There is separation in the sample itself. Solution: Stirr slowly or mix parts of the product just before measurement without introducing air

9 4. METHODS OF DENSITY MEASUREMENT The main methods which can be used in an industrial environment are: Pycnometer (Appendix 1) Plunger (Appendix 2) Use of product container Line marked bottle (Appendix 3) Container filled with water to its edge (Appendix 4) Hydrometer (Appendix 5) Electronic portable densimeter (Appendix 6) Laboratory methods of density measurement: Electronic densimeter, laboratory type (Appendix 7) Mohr's balance (Appendix 8) Plunger method for putties (Appendix 9) 5. FIELDS OF APPLICATION OF THE METHODS OF MEASUREMENT Product Method a) Liquids without - plunger (gamma sphere) CO 2 or other gas - metallic pycnometer - hydrometer - electronic densimeter b) Products with or without CO 2 - line marked bottle in transparent but not deformable container c) Products including CO 2 - not easily measurable, in non transparent container leave CO 2 to escape then follow a) d) Viscous liquids - metallic pycnometer - electronic densimeter, laboratory type e) Putties - plunger method for putties - pycnometer with non-dissolving liquid f) Aerosol products - electronic densimeter, laboratory type - special high pressure pycnometer g) Products in several phases - container used as pycnometer and in non-deformable and non- filled with water transparent container h) Products in several phases - transfer the product into an Erlenin deformable containers mayer bottle used as pycnometer, see g) - 6 -

10 Appendix 1 PYCNOMETER DESCRIPTION Pycnometers are measures in glass or metal having a fixed volume content. The pycnometer is closed by a stopper or lid in which there is a small hole which enables air and excess of the product to be eliminated so that the quantity contained in the pycnometer is constant after completion of the filling operation. The capacity of pycnometers varies but is frequently 50 or 100 ml. The latter value or more is preferable to obtain the best accuracy. The use of pycnometers with a capacity smaller than 25 ml is not advised. Important: The exact volume contained in the pycnometer may, with respect to highest accuracy, be different from the nominal (marked) capacity. FIELDS of APPLICATION Glass pycnometers: filling with non dissolving liquids: Metal pycnometers: (screwed lid) etc.) - clear liquids without CO2 or other solutes under pressure - pasty products: putties, glues, products conditioned in deformable tubes - viscous and slightly pasty products (products for* cleaning, lacquers NECESSARY EQUIPMENT - Calibrated pycnometer as described above (the method of calibration should be known) - Weighing instrument with scale intervals of 10 mg (0.01 g) or less for a 100 ml pycnometer and 1 mg (0.001 g) or less for a 25 ml pycnometer - Weights of accuracy class M 1 - Mercury thermometer graduated in 0.1 or 0.2 C intervals - Thermostated bath - 7 -

11 Appendix 1 Fig. 1 - Pycnometers, from left to right: metal pycnometer, 100 ml glass pycnometers, 50 ml, 10 ml, 5 ml metal pycnometer, 5 ml Fig. 2 - Metal pycnometer, tissue paper used to wipe off excess product - 8 -

12 Appendix 1 PREPARATION and MEASUREMENTS A. Method without use of non-dissolving ancillary liquid Clean the pycnometer with water and alcohol. Apply a fine film of vaseline to the upper edge of the pycnometer so as to ensure tightness of the lid. Place the pycnometer and its lid on the weighing instrument and record the weighing result (M 0 ). Fill the pycnometer very carefully by avoiding the introduction of air bubbles. Also avoid as far as possible to put the product on the walls close to the location of the lid. The filling level should be such that after adjusting definitely the stopper or the lid (see below) a small quantity of the product can escape through the opening. Place the stopper or the lid loosely on the pycnometer and place the whole in a thermostatic bath operating at 20 C _± 0.2 C. Take out and dry the pycnometer after 20 to 30 minutes, rather quickly so as to avoid temperature drift. The stopper or the lid of the pycnometer is then placed or screwed firmly on and the excess of product wiped off with a suitable tissue paper placed around the stopper or around the hole in the lid. The pycnometer is then weighed (Mv), emptied, cleaned, dried and weighed again together with standard weights corresponding to an approximate value of Mv - Mo i.e. to the mass contained in the pycnometer. Record the indication Io of the weighing instrument. This last operation enables the determination of the correction to be applied to compensate for systematic errors of the weighing instrument. Note: Additional precautions may be necessary to avoid the introduction of air bubbles during manipulation of non-transparent viscous and pasty products using metal pycnometers. B. Method using filling with a non-dissolving ancillary liquid If the pycnometer is filled with a product from a tube or a pot one may avoid the introduction of air by first filling the pycnometer with a non-dissolving liquid of known density which does not mix with the product (water is many times suitable). One weighs in this case the empty pycnometer (see A) and then fills it with a small quantity (for instance 1/3) of the non dissolving liquid followed by a new weighing. The product to be measured is then introduced so as to approach the level of the lid of the pycnometer and the whole is weighed for the third time. The filling of the pycnometer is then completed using the non dissolving liquid followed by a fourth weighing. See A for the remainder of operations

13 Appendix 1 COMPUTATION Method A where: Mp ρ = g/ml V ρ = density of the product at 20 C Mp = apparent mass of the product M v M 0 + C where C = M 0 + additional standard weights - I 0 V = volume of the pycnometer at the temperature of measurement Note: Values used for density of air g/ml and for weights 8.0 g/ml Method B m m1 ρ = m1 m0 + m3 m V ρ L g/ml where : m 0 = weighing result (apparent mass) of empty pycnometer m 1 = pycnometer + partial filling with ancillary liquid m 2 = pycnometer + partial filling with ancillary liquid + product m 3 = pycnometer + completed filling with ancillary liquid + product ρ L = density of the ancillary liquid at the temperature of measurement

14 Appendix 1 Example of calculation using method A Empty pycnometer Fully filled pycnometer Weighing of empty pycnometer and 130 g of standard weights Correction of the weighing instrument m I 0 M 0 = g M v = g I 0 = g C = g True capacity of the pycnometer V = ml ( ) ρ = = g/ml Calibration of a pycnometer The volume of the pycnometer is V = ρ where: w M n ml V = volume of the pycnometer at the temperature of measurement M n = weighing result (apparent mass) of the water contained in the pycnometer ρ w = density of water (for instance at 20 C: g/ml) The density of air during the weighing is assumed to be g/ml

15 Appendix 2 PLUNGER (GAMMA SPHERE) DESCRIPTION The plunger is a sphere usually made from chromium plated brass fixed to a rod the length of which can be adjusted by rotation. It is available in two sizes: 100 and 10 ml (see Figure 3). The 100 ml model has a rod with line divisions to indicate depth of immersion. The use of the 10 ml model is not advised on account the rather high relative error due to surface tension of the liquids to be tested. The approximate value of the surface tension of these liquids should however also be known when using the 100 ml plunger. FIELDS of APPLICATION Clear and slightly viscous liquids with or without CO 2 or other solutes. Because of the ease of cleaning the spherical plunger is particularily recommended for use with lacquers, paints and similar products of medium viscosity. NECESSARY EQUIPMENT - Calibrated (and certified) plunger - Weighing instrument with scale intervals smaller or equal to 10 mg (0.01 g) and a weighing capacity of 800 g or more for tests with a 100 ml plunger - A set of weights class M 1 - Mercury thermometer with scale intervals of 0.1 or 0.2 C - A beaker of 500 or 600 ml - A support for holding the plunger - A thermostatic bath

16 PREPARATION and MEASUREMENTS Appendix 2 The plunger and the beaker are first cleaned. Fill then the beaker with the product until it is possible to immerse completely the sphere to the foreseen depth (for instance 300 ml). Avoid introduction of air during this operation. Place the beaker and the plunger in the thermostatic water bath set to 20 C ± 0.2 C for 20 to 30 minutes and then dry them externally as required. Place then the beaker on the balance and weigh (M 0 ) or tare if this is possible. Bring the plunger carefully into the liquid until approaching the line mark on the rod (for instance down to 5 mm from the liquid level). Turn the lower part of the rod by maintaining the upper part and bring the line mark so as to be slightly below the level of the liquid. Again turn slightly the rod to bring it upwards so as to form a good meniscus (Figure 4). The meniscus should be fully formed so as to enable to know and compute correctly the influence of surface tension on the density measurement. Read the balance at this moment and record the value (M v ). Finally, with a view of eliminating possible systematic errors of the balance, place the beaker with its liquid,but without the plunger, on the balance and add an amount of standard weights corresponding to an approximate value of the difference M v M 0 and record the indication I 0. Fig. 3 - Spherical plungers 100 and 10 ml Fig

17 COMPUTATION Appendix 2 M p π d ρ = σ V g V g/ml ρ = density of the product at 20 C in g/ml M p = apparent mass of the liquid displaced by the plunger (= M v - M 0 + C) where C is the correction determined by M 0 + additional standard weights I 0 V = volume of the plunger in ml at the temperature of measurement g = local acceleration due to gravity (for example 9.81 m/s 2 ) d = diameter of the plunger rod in mm σ = surface tension of the product in N/m π = Note: It is desirable to know as exactly as possible the value of the surface tension, otherwise errors of the order of g/ml may typically be introduced using the 100 ml sphere. The formula uses, for the density of air,the mean value g/ml and,for the standard weights, 8.0 g/ml Example of calculation using a 100 ml plunger: Measurement of the density of a paint Weighing: beaker with paint with plunger M 0 = g M v = g without plunger but with 100 g of standard weights I = correction M I 0 Volume of plunger (according to C = 0.05 g certificate) V = ml Surface tension σ = 0.04 N/m Diameter of the plunger rod d = 3 mm ρ = = g/ml Calibration of the plunger The volume of the plunger is calibrated by immersion in a liquid of known density

18 where: The exact volume of the plunger is obtained from V = π d σ M + g ( ρ ) [ 1+ ( t 20) α ] ml c V = volume of the plunger at 20 C in ml c v Appendix 2 M = apparent mass of the liquid displaced by the plunger (weighing result corrected for systematic balance errors) in g t = temperature of the measurement in C d = diameter of the plunger rod in mm g = acceleration due to gravity in m/s 2 α v = coefficient of cubic expansion of the material of the plunger in K σ c = surface tension coefficient of the liquid used for calibration expressed in N/m ρ c = density of the liquid at the temperature t and expressed in g/ml The liquid most frequently used is distilled water for which σ c N/m and ρ c = g/ml at 20 C Method for volatile products Volatile liquids mdy evaporate too quickly for using the normal method described. Measurements can in this case still be made by putting the support of the plunger on the balance (see Figure 5). Attention: In this case the positive sign of the surface tension component in the formulas must be changed to minus sign. Fig

19 Appendix 3 LINE MARKED BOTTLE DESCRIPTION This method uses the container of the product. The principle is basically the same as that of the pycnometer with the difference that the volume of the container or bottle (up to the line mark) is initially unknown. The container must a) not be deformable b) be transparent at the location of the line mark c) have a diameter at the location of the line mark (neck) which is small (not more than 35 mm). The marking of the line and the levelling of the liquids must be done carefully to avoid serious errors. FIELDS of APPLICATION - drinks containing CO 2 - non homogenous products - volatile products EQUIPMENT NECESSARY - Non-deformable and transparent bottle filled with the product to be measured - Weighing instrument with suitable capacity and having scale intervals of 10 mg for containers up to 500 ml and 100 mg for others - Thermostatic bath - Black marker, water resistant

20 PREPARATION and MEASUREMENT Appendix 3 Select a filled bottle from the production line having if possible a high level of liquid and place it in a thermostated bath at 20 ± 0.2 C during 20 to 30 minutes. Place the bottle on a horizontal surface and trace with the marker a thick vertical line crossing the level of the liquid and trace (or scratch) a horizontal line with a ball point pen across the vertical line at the location of the meniscus while observing the bottom line of the meniscus by transparency (Fig. 6). Then weigh the bottle and record the result (M v ). Empty the bottle and clean it by suitable means, then fill it with distilled water up to a level which is slightly below the horizontal line. Measure the temperature of the water in the bottle (t). Place then the bottle on the horizontal surface and fill it up to the correct level of the line mark. Close the bottle and weigh it (M w ). Empty then the bottle again and dry it completely before weighing together with its capsule or lid (M t ). If necessary one can determine and take into account the systematic errors of the weighing instrument by making separate measurements using standard weights approaching the indications M v, M w and M t for which the corrections designated as C v, C w and C t apply, see the example of computation below. Fig. 6 - Marking of level

21 Appendix 3 COMPUTATION ρ = The general formula for the line marked bottle method is M p ( ρ ) g/ml w + M n ρ = density of the product at 20 C in g/ml ρ w = density of water at t C in g/ml M p = apparent mass of the product in g = (M v + C v ) - (M t + C t ) M n = apparent mass of water in the bottle in g = (M w + C w ) - (M t + C t ) Example for a bottle containing a carbonated drink: Bottle + product + capsule Bottle + water + capsule Empty bottle + capsule Indication for g of standard weights Correction Indication for 1930 g standard weights Correction Indication for 930 g of standard weights Correction M v = g M w = g M t = g g C v = g g C w = g g C t = g Temperature of water t = 17.4 C Density of water according to Table (page 31) at t = 17.4 C ρ w = g/ml ( ) ( ) ( ) ( ) ( ) ρ = = g/ml

22 Appendix 4 CONTAINER FILLED WITH WATER TO ITS EDGE DESCRIPTION This method, like that of the line marked bottle, uses the product container as a pycnometer but with a lid made from methylmethacrylate ("Plexiglass" or "Perspex") in which a small hole defines the level. The container must a) not be deformable b) have a flat edge c) be so designed that air cannot be entrapped after complete filling. This method is much less accurate than the preceding ones but still valid for certain applications. FIELDS of APPLICATION Containers completely filled containing water: inhomogeneous products such as soups, drinks containing fruit, paint in several phases, etc. Important: Water must not modify the molecular structure of the product itself. NECESSARY EQUIPMENT - Container or non-deformable bottle with flat upper edge of such shape that air cannot be entrapped during filling with water - Weighing instrument with a scale interval equal to or less than 10 mg for containers with a capacity smaller than 500 ml and 100 mg (0.1 g) for containers of 500 ml or more. - Lid made of glass or methylmethacrylate ("Plexiglass" or "Perspex") with a hole at the centre (see Figure 8) - Thermometer with scale intervals of 0.1 or 0.2 C - Thermostatic bath

23 PREPARATION and MEASUREMENTS Appendix 4 Take a closed container from the production line and put it for 20 to 30 minutes in the thermostated bath set at 20 ± 0.2 C. Open the container and grease the edge with vaseline to affect a seal for the special lid. Put the container on the balance as well as the lid (separately) and weigh the whole (M p ). Add water at 20 C to the container up to 5 mm from the edge, adjust the lid on the container so that its opening is in the centre and place the whole on the balance. Add water carefully to the defined level (see Figure 9) without introducing air bubbles under the lid. If such are present tap slightly on the lid and complete the filling. Record the indication of the new weighing (M s ). Empty, clean and dry the container carefully and lightly grease the edge. Weigh the empty container together with the lid (M t ). Fill the container with distilled water until about 10 mm from the edge and measure the temperature of the water (t). Adjust the lid on the container, place the whole on the balance, complete the filling with water and record the indication of the balance (M w ). Determine if necessary the corrections for the weighing instrument using standard weights of approximately the same values as the indications M p, M s, M t and M w ; The corresponding corrections are designated C p, C s, C t and C w. Fig. 8 - Lid of plexiglass (perspex) Fig. 9 - Adjustment of liquid level Fig. 7 - Use of special lid on bottle or can (container used as pycnometer)

24 Appendix 4 Fig Weighing of container, product and lid (M p ) Fig Adjustment of level with water and weighing (M s ) Fig Weighing of empty container and lid (M t ) Fig Filling with water, adjustment of lid and weighing (M w )

25 Appendix 4 COMPUTATION The general formula for the density in this case is ρ = where: M M p t ( ρ ) g/ml w + M p M t + M w M s ρ = density of the product at 20 C in g/ml ρ w = density of water at t C in g/ml M p ' = M p +C p M s ' = M s +C s M t ' = M t +C t M w ' = M w +C w EXAMPLE Tomato soup in 1 l container Opened container with product and special lid M p = g Container with lid product and additional water M s = g Container with lid,entirely filled with water M w = g Empty container with lid M t = g Indication for 950 g of standard weights g Corrections C p and C w = 0.08 g Indication for 1000 g standard weights g Correction C s = 0.05 g Indication for 95 g of standard weighty g Correction C t = g M p = g M s = = g M w = = g M t = = g Temperature of water t = 17.8 C Density of water at t = 17.8 C according to Table ρ w = g/ml ρ = = ( ) g/ml

26 Appendix 5 HYDROMETER DESCRIPTION The hydrometer has a cylindrical body made from glass. Its lower part which is immersed in use, is filled with ballast material and the upper part which is partially immersed in use has the form of a narrow graduated tube. The method of operation is based on the principle of Archimedes, the plunging depth depending on equilibrium between the weight of the hydrometer and the upthrust force determined by the weight of the displaced liquid. There are various types of hydrometers: - with or without incorporated thermometer - of various accuracies: 0.02 to g/ml - different ranges (depending on accuracy). The most commonly used type for the measurement of density in the field of prepackage control in Europe (with "e"-mark) is a hydrometer without incorporated thermometer and with an accuracy of g/ml. Because of the narrow range of each hydrometer (0.05 g/ml), nine hydrometers are necessary to cover the range from to g/ml. The correct use, or adjustment, also depends on the type of product to be measured: if the liquid is transparent the reading can be taken on the line determined by the bottom of the meniscus (see Figure 15); if this is not the case it is necessary to take the reading at the top of the meniscus. It is also necessary to take into account the surface tension of the liquid to be measured which must be known with respect to the liquid used for the calibration of the hydrometer. A weighing instrument is not required. FIELDS of APPLICATION Non carbonated liquids, liquid products with low viscosity and in a homogeneous phase. NECESSARY EQUIPMENT - Certified hydrometer, accurate to g/ml for the products concerned, - Mercury thermometer with scale intervals of 0.1 or 0.2 C, - Cylindrical container of sufficient height and not too narrow, - Thermostatic bath,

27 PREPARATION and MEASUREMENTS Appendix 6 The glass cylinder and the hydrometer must first be carefully cleaned. The glass cylinder is filled with the liquid to be measured without introducing air bubbles. Place the cylinder with the product and the hydrometer in the thermostatic bath to obtain a uniform temperature of 20 C. Lift the hydrometer and drop it very gently so that it floats freely and vertically in the product. Take several readings of the equilibrium position, each time after producing a small vertical movement. The readings are taken using either the bottom line or the top of the meniscus depending on the type of liquid and the calibration. COMPUTATION The density of the product is ρ - reading + correction factor in g/ml The correction factor is stated individually in the certificate of calibration of each hydrometer. Fig Hydrometer in use Fig Reading of meniscus for transparent liquids

28 PORTABLE ELECTRONIC DENSITY METER Appendix 6 DESCRIPTION Electronic density meters are commercially available which have scale intervals of g/ml in density and 0.1 C in temperature and which may be suitable for density measurements of prepacked products. Their principle is based on the measurement of the natural frequency of a U-shaped glass tube which has a constant volume at a given temperature. This frequency is related to the mass of the tube and thus to the density of the product contained in it. The display indicates density directly in g/ml. This type of instrument may not include temperature control but can allow temperature to be taken into account by computation. The incorporated thermometer can be accurate to 0.5 C and the density indication to g/ml. It is generally necessary to use the instrument within the following operating ranges: - the density of the product should be within the range of 0.7 to 1.2 g/ml - the operating temperature should be within + 10 to + 30 C. The instrument may be used in two ways: - with an incorporated rubber suction bulb - with external plastic syringes. The first method is not advised as it may easily introduce air bubbles leading to errors in the measured density values. The small sample quantity required has a low thermal capacity and its temperature is therefore rapidly adjusted to the ambient temperature as indicated by the instrument. As the volume expansion coefficient of the products is generally not known it is preferable to operate at the temperature of 20 C. Important: As glass is fragile, it is necessary to avoid pressure in the U- tube as well as heavy and viscous products. FIELDS of APPLICATION According to the manufacturer's specifications, and generally: non viscous liquids which do contain neither air nor carbon dioxide and for which the density lies in the range of 0.7 to 1.2 g/ml

29 NECESSARY EQUIPMENT Appendix 6 - Portable electronic density meter which is calibrated (certified) and adjusted before measurements - Distilled water for this adjustment - Plastic syringes, capacity 2 ml - Suction bulb or aquarium pump - Mercury thermometer with 0.1 or 0.2 C scale intervals - Installation requirements in accordance with manufacturer's instructions PREPARATION Control the calibration of the density meter every time before use, or at least once at the beginning of each day of use. Use a syringe for injecting distilled water as specified by the manufacturer, after having eliminated any air bubbles. Wait the time specified by the manufacturer. Read the density and the corresponding temperature. If the density differs from that indicated in the Table 1 by more than g/ml the instrument shall be adjusted using the device provided therefore. Then empty the measurement cell, rinse with alcohol and dry it. The zero indication without product shall be or or g/ml. Otherwise start the calibration operation again. Fig Filling of a portable electronic density meter using a plastic syringe

30 MEASUREMENTS Appendix 6 Fill two or three syringes with the sample product. Eliminate the air by tapping while holding the syringe needle upwards. Measure the ambient temperature with a separate thermometer. The ambient temperature shall preferably be between 19.5 and 20.5 C, however density measurements can still be made if this is not the case. One can distinguish between three situations: A. The ambient temperature is comprised between 19.5 and 20.5 C B. It is lower than 19.5 C C. It is higher than 20.5 C Case A. The product can be introduced directly in the density meter using a syringe. Wait until the temperature indicated by the instrument does no longer vary. Then read the density to g/ml. Repeat the operation using the second syringe. In case of doubt use the third syringe for confirmation of result. Case B. The same procedure as for A, after having first placed the syringe in a stream of water at for instance 25 C, making the injection and then leaving the temperature to drop to 20.0 C as indicated by the thermometer of the instrument. Case C. The same procedure as B but by cooling first the sample in a stream of water at for instance 15 C. In the three cases the measurement of density is made by direct reading of the instrument and valid for the temperature of 20 C. After each measurement, clean the measuring cell of the density meter with water and alcohol and dry it using the suction ball or the aquarium pump. Fig, 17 - Cleaning of the electronic density meter

31 Appendix 7 ELECTRONIC DENSITY METERS FOR LABORATORY USE These types of density meter which are of higher accuracy than the portable type also use the natural frequency of a tube filled with the product to be measured. They may incorporate temperature regulation or require the use of an external thermostatic bath. Some types may withstand higher pressures, up to 10 bar, and thus enable density measurements of aerosol products. FIELDS of APPLICATION These instruments allow measurements on all products whether liquid or pasty but which do not contain air bubbles or CO 2. For the correct use of the instruments it is necessary to follow the manufacturer's instructions. Appendix 8 HYDROSTATIC BALANCE (MOHR's BALANCE) (for LABORATORY USE ONLY) The operation of this balance is based on the principle of Archimedes. The balance weighs a plunger hanging on a fine metallic wire. The plunger is usually a cylinder with a volume from 1 to 10 ml. The difference between the result of weighing in air and the result of weighing in the liquid enables the determination of the density of the liquid. In the so-called MOHR's balance the plunger is previously balanced in air so that the amount of weights added to reestablish equilibrium in the liquid furnishes directly density values in g/ml. Commercial Mohr f s balances of this type with direct reading do usually not allow to reach high accuracy (at best about g/ml) though the principle when adapted on an analytical balance may, subject to problems with surface tension, enable measurements to g/ml on thermostatically controlled liquids. For application and operation follow the manufacturer's instructions

32 Appendix 9 PLUNGER METHOD for PUTTIES Principle: The sample of the product is immersed in a liquid with known density. The difference between weighing in air and in the liquid enables to calculate the density. NECESSARY EQUIPMENT -Beaker, capacity 600 ml -Distilled water at 20 C -Thin brass or copper strips -Nylon or metal wire (for instance fishing line 0.18 mm) -Balance equipped for hydrostatic weighing scale interval 1 mg (0.001 g) or smaller -Support for the balance so as to allow weighing below its pan -Small platform support, adjustable in height, for the beaker. MEASUREMENTS (Fig. 18 to 21) a) Attach the metal strip to the wire and suspend it under the balance. Take the balance reading for the strip in air - M 1 b) Place the beaker half filled with water at 20 C under the balance so that the metal strip is fully immersed. Take the reading of the balance with the strip in water - M 2 c) Remove the metal strip from thebeaker, dry it and cover it carefully with the putty lengthwise. Remove the beaker and weigh the product and the strip in air - M 3 d) Bring the beaker under the balance and weigh the product and the strip fully immersed in water - M 4 Correct, if necessary, the readings M1 through M4 for systematic errors of the balance. COMPUTATION M M1 ρ = M M M + M 3 ( ρ ) g/ml 3 + w where: ρ = density of the product at the temperature of measurement ρ w density of water at the temperature of measurement (from Table) Note: If the product to be tested dissolves in water, use another reference liquid (methanol or methyl-ethyl-ketone(mek) for silicon putties)

33 PLUNGER METHOD FOR PUTTIES Appendix 9 Fig Weighing of strip in air (Ml) Fig Weighing of strip in water (M2) Fig Weighing in air of strip covered with putty (M3) Fig. 21 -Weighing in water of strip with putty (M4)

34 Appendix 9 DENSITY OF AIR FREE WATER AS A FUNCTION OF TEMPERATURE Values are expressed in kg/m 3. To obtain values in g/ml divide by (From a paper by H. Wagenbreth and W. Blanke published in PTB-Mitteilungen No.6, 1971, p )

INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method

INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method INTERNATIONAL OIML R 69 RECOMMENDATION Edition 1985 (E) Glass capillary viscometers for the measurement of kinematic viscosity - Verification method Viscosimètres à capillaires, en verre, pour la mesure

More information

Dry matter content and fibre content

Dry matter content and fibre content Revised 1996 Black liquor Dry matter content and fibre content 0 Introduction This SCAN-test Standard replaces SCAN-N 22:77 from which it differs in that it also provides a procedure for the determination

More information

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS Revision index Effective date B 15/02/2015 ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS 4, avenue du Recteur-Poincaré, 75782 Paris Cedex 16 Tel. 33 (0)1.64.68.84.97 Fax. 33 (0)1.64.68.83.45

More information

Density (d) is a property of a substance equal to the ratio of its mass (m) to its volume (V): d = m V

Density (d) is a property of a substance equal to the ratio of its mass (m) to its volume (V): d = m V Experiment 2 Name: DEN 14 Si TY In this experiment, you will learn about density and practice the proper way to report measurements and calculated quantities. Properties Properties of a substance can be

More information

TESTS ON AGGREGATES 58

TESTS ON AGGREGATES 58 TESTS ON AGGREGATES 58 59 3.1 DETERMINATION OF INDICES (FLAKINESS AND ELONGATION) STANDARD IS: 2386 (Part 1) 1963. DEFINITION The Flakiness Index of aggregates is the percentage by weight of particles

More information

Effect of Heat and Air on Asphalt Materials (Thin-Film Oven Test)

Effect of Heat and Air on Asphalt Materials (Thin-Film Oven Test) Standard Method of Test for Effect of Heat and Air on Asphalt Materials (Thin-Film Oven Test) AASHTO Designation: T 179-05 (2009) 1 ASTM Designation: D 1754-97 (2002) American Association of State Highway

More information

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1 Designation: D 1754 97 Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1 This standard is issued under the fixed designation D 1754; the number immediately

More information

OFI Testing Equipment Retort Analysis Instructions Part #s ,14,80 Page 1 of 4 RETORT ANALYSIS

OFI Testing Equipment Retort Analysis Instructions Part #s ,14,80 Page 1 of 4 RETORT ANALYSIS OFI Testing Equipment Retort Analysis Instructions Part #s 165-00,14,80 Page 1 of 4 RETORT ANALYSIS 10 ml Size - OFI 165-00 Series 20 ml Size - OFI 165-80 Series 50 ml Size - OFI 165-14 Series The retort

More information

IDENTIFYING UNKNOWN SUBSTANCES

IDENTIFYING UNKNOWN SUBSTANCES IDENTIFYING UNKNOWN SUBSTANCES LAB 15 EXPERIMENT STUDENT BOOK Chapter 1, page 25 TOOLBOX Page 4 and 36 Goal Identify unknown substances with the help of different tests. 1. What is the independent variable

More information

OIML R 79 RECOMMENDATION. Edition 2015 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Labeling requirements for prepackages

OIML R 79 RECOMMENDATION. Edition 2015 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Labeling requirements for prepackages INTERNATIONAL RECOMMENDATION OIML R 79 Edition 2015 (E) Labeling requirements for prepackages Exigences pour l étiquetage des préemballages OIML R 79 Edition 2015 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE

More information

Experiment: Measurements

Experiment: Measurements Experiment: Measurements I. INTRODUCTION Measurements are essential to experimental sciences such as chemistry, physics, biology, and geology. The measurements are usually made using the metric system

More information

DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES

DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES Test Procedure for DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES TxDOT Designation: Tex-212-F Effective Date: March 2016 1. SCOPE 1.1 Use this test method to determine the moisture content of any

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 205-10 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the quantitative determination of the distribution of particle sizes in soils. The distribution

More information

Concrete Field Testing Technician Study Guide

Concrete Field Testing Technician Study Guide Concrete Field Testing Technician Study Guide ASTM C 172 SAMPLING FRESH CONCRETE 1. The maximum allowable time between obtaining the first and final portions of a composite sample is minutes. (Section

More information

Elcometer Specific Gravity Cup (Densimeter) (Picnometer or Pyknometer) Operating Instructions

Elcometer Specific Gravity Cup (Densimeter) (Picnometer or Pyknometer) Operating Instructions Elcometer 1800 English Specific Gravity Cup (Densimeter) (Picnometer or Pyknometer) Operating Instructions English is a registered trademark of Elcometer Ltd. All other trademarks acknowledged. Copyright

More information

Experiment 1: The Densities of Liquids and Solids (from Masterson & Hurley)

Experiment 1: The Densities of Liquids and Solids (from Masterson & Hurley) Experiment 1: The Densities of Liquids and Solids (from Masterson & Hurley) One of the fundamental properties of any sample of matter is its density, which is its mass per unit of volume. The density of

More information

Laboratory Manual. Concrete and aggregate. Content

Laboratory Manual. Concrete and aggregate. Content Laboratory Manual Concrete and aggregate Content Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Section 9 Trial Mix Slump Density of Compacted Fresh Concrete Making of

More information

BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE

BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE Test Procedure for BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE Texas Department of Transportation TxDOT Designation: Tex-201-F Effective Dates: November 2004 December 2010. 1. SCOPE 1.1 This

More information

Name Lab Section Date. Sediment Lab

Name Lab Section Date. Sediment Lab Name Lab Section Date. Investigating Stokes Law Sediment Lab ds = density of solid, g/cm dw = density of water, g/cm g = gravity, 980 cm/second 2 D = particle diameter in centimeters μ = molecular viscosity,

More information

Density. The purpose of this experiment is to investigate the topic of density by determining the densities of some materials.

Density. The purpose of this experiment is to investigate the topic of density by determining the densities of some materials. Density Goals The purpose of this experiment is to investigate the topic of density by determining the densities of some materials. Introduction There is a lesson in the old bromide: Which is heavier,

More information

Thermal Conduction and Surface Area

Thermal Conduction and Surface Area Chapter 16 Thermal Energy and Heat Investigation 16A Thermal Conduction and Surface Area Background Information The quantity of energy transferred by heat from a body depends on a number of physical properties

More information

Method of Test for Theoretical Maximum Specific Gravity of Asphalt Concrete Paving Mixtures

Method of Test for Theoretical Maximum Specific Gravity of Asphalt Concrete Paving Mixtures Method of Test for Theoretical Maximum Specific Gravity of Asphalt Concrete Paving Mixtures 1. Scope: This test is to determine the theoretical maximum specific gravity and/or density of uncompacted asphalt

More information

Particle Size Distribution Analysis for Ceramic Pot Water filter production

Particle Size Distribution Analysis for Ceramic Pot Water filter production Particle Size Distribution Analysis for Ceramic Pot Water filter production Maria del Mar Duocastella and Kai Morrill Potters Without Borders, Enderby, British Columbia, Canada - September 2012 Abstract:

More information

Operating Manual for Digital ph-meter GPHR 1400

Operating Manual for Digital ph-meter GPHR 1400 Operating Manual for Digital ph-meter GPHR 1400 Specification Measuring range: Resolution: ph-electrode: conductivity Input resistance: Accuracy (unit only): Working temperature: Nominal temperature: Power

More information

BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11)

BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11) BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11) Scope This procedure covers the determination of bulk specific gravity (G mb ) of

More information

4.1 DETERMINATION OF SPECIFIC GRAVITY

4.1 DETERMINATION OF SPECIFIC GRAVITY TESTS ON CEMENT 94 4.1 DETERMINATION OF SPECIFIC GRAVITY STANDARD IS: 4031-1988. DEFINITION Specific Gravity is defined as the ratio of the mass of the cement to the mass of an equal volume of kerosene.

More information

M. It is expressed in units such a g/cc,

M. It is expressed in units such a g/cc, Experiment 2 Density Part I: Density of a solid Density is defined as mass per unit volume, D = V M. It is expressed in units such a g/cc, g/ml, lb/ft 3, etc. Determination of mass is done by weighing

More information

PHYSICAL CHANGE OR CHEMICAL CHANGE?

PHYSICAL CHANGE OR CHEMICAL CHANGE? PHYSICAL CHANGE OR CHEMICAL CHANGE? STUDENT BOOK Chapter 2, page 58 LAB 24 OBSERVATION TOOLBOX Pages 18 19, 32, 39 40 Goal Distinguish between a physical change and a chemical change. Observation criteria

More information

OIML D 24 DOCUMENT. Edition 1996 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Total radiation pyrometers DE MÉTROLOGIE LÉGALE

OIML D 24 DOCUMENT. Edition 1996 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Total radiation pyrometers DE MÉTROLOGIE LÉGALE INTERNATIONAL DOCUMENT OIML D 24 Edition 1996 (E) Total radiation pyrometers Pyromètres à radiation totale ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL ORGANIZATION OF LEGAL METROLOGY

More information

Bulk Density Protocol

Bulk Density Protocol Bulk Density Protocol Purpose To measure the bulk density of each horizon in a soil profile Overview In the field, students collect three soil samples from each horizon in a soil profile using a container

More information

CEEN Laboratory 1 Mechanical Sieve Analysis Specific Gravity of Soil Solids Gravimetric/Volumetric Relations

CEEN Laboratory 1 Mechanical Sieve Analysis Specific Gravity of Soil Solids Gravimetric/Volumetric Relations INTRODUCTION CEEN 3160 - Laboratory 1 Mechanical Sieve Analysis Specific Gravity of Soil Solids Gravimetric/Volumetric Relations Grain size analysis is widely used for the classification of soils and for

More information

METHOD A6 THE DETERMINATION OF THE GRAIN SIZE DISTRIBUTION IN SOILS BY MEANS OF A HYDROMETER

METHOD A6 THE DETERMINATION OF THE GRAIN SIZE DISTRIBUTION IN SOILS BY MEANS OF A HYDROMETER METHOD A6 THE DETERMINATION OF THE GRAIN SIZE DISTRIBUTION IN SOILS BY MEANS OF A HYDROMETER SCOE This method covers the quantitative determination of the distribution of particle sizes in soils. The distribution

More information

1. Fineness Standard EN describes two methods of determining the fineness of cement: sieving method air permeability method ( Blaine)

1. Fineness Standard EN describes two methods of determining the fineness of cement: sieving method air permeability method ( Blaine) TESTING of CEMENT (EN 197 Standard) 1. Fineness Standard EN 196-6 describes two methods of determining the fineness of cement: sieving method air permeability method ( Blaine) Sieving Method This method

More information

Name Honors Chemistry / /

Name Honors Chemistry / / Name Honors Chemistry / / SOL Questions Chapter 1 Each of the following questions below appeared on an SOL Chemistry Exam. For each of the following bubble in the correct answer on your scantron. 1. The

More information

CONCRETE TECHNOLOGY LABORATORY

CONCRETE TECHNOLOGY LABORATORY CONCRETE TECHNOLOGY LABORATORY DEPARTMENT OF CIVIL ENGINEERING CHULALONGKORN UNIVERSITY Tested by... ID No.... Date... Graded by... TEST No. C-4 MIXING, CASTING AND PROPERTIES OF FRESH CONCRETE (I) Part

More information

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge International General Certificate of Secondary Education www.xtremepapers.com Cambridge International Examinations Cambridge International General Certificate of Secondary Education *2872917612* PHYSICAL SCIENCE 0652/61 Paper 6 Alternative to Practical October/November

More information

Salinity in Seawater

Salinity in Seawater Salinity in Seawater Objective To familiarize students with the different methods used for measuring salinity of water. Introduction: Salinity exerts profound impacts on the marine environment. It controls

More information

ES 106 Laboratory # 1 PROPERTIES OF WATER

ES 106 Laboratory # 1 PROPERTIES OF WATER ES 106 Laboratory # 1 PROPERTIES OF WATER 1-1 Introduction What are the physical and chemical properties of water that make it so unique and necessary for living things? When you look at water, taste and

More information

VISCOSITY, INHERENT (One Point)

VISCOSITY, INHERENT (One Point) VISCO.02-1 VISCOSITY, INHERENT (One Point) PRINCIPLE SCOPE A weighed starch sample is dispersed in sodium hydroxide solution using a standard technique. Relative viscosity of the sample dispersion is determined

More information

Experiment 2: The Chromatography of Organic Compounds

Experiment 2: The Chromatography of Organic Compounds Experiment 2: The Chromatography of Organic Compounds INTRODUCTION When performing an organic reaction, it is very common to observe the formation of other compounds in addition to your desired product;

More information

Good Practice Guide for nanoindentation of nanoparticles embedded in a layer using an SEM in situ technique

Good Practice Guide for nanoindentation of nanoparticles embedded in a layer using an SEM in situ technique Sample preparation The particles to be tested were two sizes of silica spherical particles, nominally sized 300 nm and 100 nm in diameter, gold spherical particles, nominally sized 60 nm in diameter, and

More information

Lab Report: Thermal Energy Transfer in Mixtures

Lab Report: Thermal Energy Transfer in Mixtures Lab Report: Thermal Energy Transfer in Mixtures Purpose: The purpose of this experiment is to discover how exactly the final temperature of a mixture, involving a substance and hot water, is affected and

More information

Copper Odyssey. Chemical Reactions of Copper

Copper Odyssey. Chemical Reactions of Copper Name Lab Partner(s) Copper Odyssey Chemical Reactions of Copper Date Period Elemental copper metal will be converted into copper (II) ion and then brought through a series of compound conversions until

More information

Circular Expansion Cement Curing Kit Instruction Manual

Circular Expansion Cement Curing Kit Instruction Manual Circular Expansion Cement Curing Kit Instruction Manual Manual No. 101443617, Revision C Instrument No. 205814 2015 Fann Instrument Company 2015 Fann Instrument Company Houston, Texas, USA All rights reserved.

More information

GEL Hydrogeology (Groundwater) LAB 2: POROSITY & HYDRAULIC CONDUCTIVITY - Porosity Segment - Grade: /25

GEL Hydrogeology (Groundwater) LAB 2: POROSITY & HYDRAULIC CONDUCTIVITY - Porosity Segment - Grade: /25 GEL 4250 - Hydrogeology (Groundwater) LAB 2: POROSITY & HYDRAULIC CONDUCTIVITY - Porosity Segment - Name: Section: Grade: /25 COMPLETE & TURN IN ONLY PAGES THAT HAVE A FIELD FOR YOUR NAME. ALL OTHER PAGES

More information

EAST AFRICAN STANDARD

EAST AFRICAN STANDARD ICS 77.140.20 HS 7210.41.00 HS 7210.49.00 EAST AFRICAN STANDARD Galvanized plain and corrugated steel sheets Specification EAST AFRICAN COMMUNITY EAC 2008 Second Edition 2008 Foreword Development of the

More information

PHARMACOPOEIAL DISCUSSION GROUP BULK AND TAPPED DENSITY OF SOLIDS

PHARMACOPOEIAL DISCUSSION GROUP BULK AND TAPPED DENSITY OF SOLIDS PHARMACOPOEIAL DISCUSSION GROUP BULK AND TAPPED DENSITY OF SOLIDS It is understood that sign-off covers the technical content of the draft and each party will adapt it as necessary to conform to the usual

More information

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION EXPERIMENT 7A Chemical Separation by Filtration and Recrystallization INTRODUCTION The solubilities of solid substances in different kinds of liquid solvents vary widely. Substances that we call salts

More information

National food safety standard

National food safety standard Translated English of Chinese Standard: GB4789.26-2013 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net ICS 65.020.30 GB B 40 NATIONAL STANDARD OF THE PEOPLE S

More information

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V. for the bonding of facade cladding with KOMO-certified bonding system Dynamic Bond METALS - HPL - FIBRECEMENT Dynamic Bond For panels up to the maximum diagonal. Based on MS-hybrid-polymers, one component.

More information

ISO 8967 IDF 134 INTERNATIONAL STANDARD. Dried milk and dried milk products Determination of bulk density

ISO 8967 IDF 134 INTERNATIONAL STANDARD. Dried milk and dried milk products Determination of bulk density INTERNATIONAL STANDARD ISO 8967 IDF 134 Second edition 2005-12-15 Dried milk and dried milk products Determination of bulk density Lait sec et produits laitiers en poudre Détermination de la masse volumique

More information

COMPOSITION OF SEAWATER

COMPOSITION OF SEAWATER COMPOSITION OF SEAWATER Ocean water is a combination of freshwater and a variety of dissolved substances. Salinity is a measure of the amount of dissolved salts in seawater, measured in parts per thousand

More information

Specific Heat. q = csm T (1)

Specific Heat. q = csm T (1) INTRODUCTION Just as people can be identified by their appearance and their behavior, substances are described and identified by their physical (appearance) and chemical (behavior) properties. Physical

More information

2. Crystallization. A. Background

2. Crystallization. A. Background 2. Crystallization A. Background Crystallization is one of several available techniques available to purify organic compounds. Unlike other techniques, however, crystallization is specific to the purification

More information

Foam extinguishing agent

Foam extinguishing agent Translated English of Chinese Standard: GB15308-2006 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF THE GB PEOPLE S REPUBLIC OF CHINA ICS 13.220.10 C 84 GB 15308-2006 Replacing

More information

Test specimens from asphalt mixture pavement will be sampled according to AASHTO R 67.

Test specimens from asphalt mixture pavement will be sampled according to AASHTO R 67. BULK SPECIFIC GRAVITY (Gmb) OF COMPACTED ASPHALT MIXTURES USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 Scope This procedure covers the determination of bulk specific gravity (Gmb) of compacted

More information

EXPERIMENT 3: Identification of a Substance by Physical Properties

EXPERIMENT 3: Identification of a Substance by Physical Properties EXPERIMENT 3: Identification of a Substance by Physical Properties Materials: Hot plate Digital balance Capillary tubes (3) Thermometer Beakers (250 ml) Watch glass Graduated Cylinder (10 ml) Mel-Temp

More information

Lab Question from Board papers Class-09[2018] 1. How will you separate a mixture of iron filings, iodine and common salt?

Lab Question from Board papers Class-09[2018] 1. How will you separate a mixture of iron filings, iodine and common salt? Lab Question from Board papers Class-09[2018] SET-1 Short Answer Type Questions (2 marks) 1. How will you separate a mixture of iron filings, iodine and common salt? Ans. (i) Remove iron filings with the

More information

Color, True and Apparent, LR

Color, True and Apparent, LR Color, True and Apparent, LR DOC316.53.01252 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 3 to 200 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method

More information

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

PORTABLE ph METER PRICE CODE NUMBER MODEL 100 PORTABLE METER MODEL 100 PRICE CODE NUMBER 56-0032 Refer to Bulletin A-301. OPERATION AND SERVICE GUIDE O-670A DEC. 1997 GENERAL INFORMATION Model 100 meter is designed for measuring over the entire 0

More information

Experiment #3. Density and Specific Gravity.

Experiment #3. Density and Specific Gravity. Experiment #3. Density and Specific Gravity. Goals 1. To measure and calculate the density and specific gravity of various substances. 2. To use significant figures correctly in calculations. Background

More information

EDICT ± OF GOVERNMENT

EDICT ± OF GOVERNMENT EDICT ± OF GOVERNMENT Inordertopromotepubliceducationandpublicsafety,equal justiceforal,abeterinformedcitizenry,theruleoflaw,world tradeandworldpeace,thislegaldocumentisherebymade availableonanoncommercialbasis,asitistherightofal

More information

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE SCOPE This test method describes the procedure for determining the density

More information

Standard Test Method for Particle-Size Analysis of Soils 1

Standard Test Method for Particle-Size Analysis of Soils 1 Designation: D 422 6 (Reapproved 2002) Standard Test Method for Particle-Size Analysis of Soils 1 This standard is issued under the fixed designation D 422; the number immediately following the designation

More information

European Pharmacopoeia

European Pharmacopoeia i PHARMACOPOEIAL DISCUSSION GROUP REV 1 - CORR 1 G02 Bulk density and tapped density of powders It is understood that sign-off covers the technical content of the draft and each party will adapt it as

More information

VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK CE 6306 - STRENGTH OF MATERIALS UNIT I STRESS STRAIN DEFORMATION OF SOLIDS PART- A (2 Marks) 1. What is Hooke s Law? 2.

More information

2. Crystallization. A. Background

2. Crystallization. A. Background 2. Crystallization A. Background Crystallization is one of several available techniques available to purify organic compounds. Unlike other techniques, however, crystallization is specific to the purification

More information

Chem 355 Jasperse DISTILLATION

Chem 355 Jasperse DISTILLATION Chem 355 Jasperse DISTILLATION 1 Background Distillation is a widely used technique for purifying liquids. The basic distillation process involves heating a liquid such that liquid molecules vaporize.

More information

OHD L-54 STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES

OHD L-54 STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES Oklahoma D.O.T. Page 1 of 7 1 SCOPE 1.1 This method covers procedures for making, curing, and testing cylindrical

More information

Experiment 3: The Chromatography of Organic Compounds

Experiment 3: The Chromatography of Organic Compounds Experiment 3: The Chromatography of Organic Compounds INTRODUCTION Very often, in an organic synthesis, a reaction will proceed to produce multiple products or perhaps will only partially form the desired

More information

UCI KCCAMS Facility. Leaching/hydrolysis protocol (carbonate samples) December 26, 2011

UCI KCCAMS Facility. Leaching/hydrolysis protocol (carbonate samples) December 26, 2011 UCI KCCAMS Facility Leaching/hydrolysis protocol (carbonate samples) December 26, 2011 Summary Leaching 1. Label a Vacutainer and tare on the balance 2. Crush a carbonate sample to coarse powder and weigh

More information

SUPER FRESHNESS METER KV-202. Instruction Manual

SUPER FRESHNESS METER KV-202. Instruction Manual 041109. SUPER FRESHNESS METER KV-202 Instruction Manual Rapid measurement of K value, the decisive factor in freshness, is now possible. Reliable instrumentation is also available, eliminating virtually

More information

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION AIM The main objective of this experiment is to determine the concentration of sulfate ion in an unknown solution by using gravimetry. INTRODUCTION

More information

COPPER CYCLE EXPERIMENT 3

COPPER CYCLE EXPERIMENT 3 COPPER CYCLE EXPERIMENT 3 INTRODUCTION One simple way to state the aim of chemistry is: The study of matter and its transformations. In this experiment, a copper sample will appear in five different forms

More information

SIGNIFICANT FIGURES WORKSHEET

SIGNIFICANT FIGURES WORKSHEET SIGNIFICANT FIGURES WORKSHEET PART 1 - Determine the number of significant figures in the following numbers. 1.) 0.02 2.) 0.020 3.) 501 4.) 501.0 5.) 5,000 6.) 5,000. 7.) 6,051.00 8.) 0.0005 9.) 0.1020

More information

Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009

Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009 Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009 January 21 st and January 28 th, 2009 T1) ASTM D4791-95: Flat and Elongated

More information

Permeability Tests. Geotechnical Engineering, Laboratory 7

Permeability Tests. Geotechnical Engineering, Laboratory 7 1. General Notes Permeability Tests Geotechnical Engineering, Laboratory 7 Be prepared to get wet. All stations, benches, and tables must be cleaned before your group leaves the lab. Please clean all glassware

More information

Water sampling. Introduction

Water sampling. Introduction MOBILE NOTE 49 Water sampling Introduction In many low-income communities, an analysis of a water supply may be required to find out whether the water is safe to drink or whether it needs to be treated

More information

Geologic Sequestration Science

Geologic Sequestration Science Geologic Sequestration Science Goal: Students learn about geologic sequestration as a technique used to reduce carbon dioxide in the atmosphere. Objectives: Students will Understand geologic sequestration

More information

Commonwealth of Pennsylvania PA Test Method No. 716 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 716 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 716 Department of Transportation 6 Pages LABORATORY TESTING SECTION Method of Test for DETERMINATION OF BULK SPECIFIC GRAVITY OF COMPACTED BITUMINOUS MIXTURES

More information

Parenteral Products. By: Howida Kamal, Ph.D

Parenteral Products. By: Howida Kamal, Ph.D Parenteral Products By: Howida Kamal, Ph.D Glass Rubber Plastic Glass Rubber Plastic Glass Rubber Plastic Type I borosilicate glass (Neutral ) made mainly of silica (70-80%) and boric oxide (7-13%) with

More information

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD Method 8000 DR/4000 PROCEDURE Reactor Digestion Method* (0 to 40.0** mg/l COD) Scope and Application: For water, wastewater and seawater; digestion is required. The estimated detection limit for program

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS METAL RESCUE Rust Remover Bath is your clean, safe and easy solution to removing rust from iron and steel. Metal Rescue utilizes a unique and selective chelating agent to remove rust (iron oxide) without

More information

Experiment #3. Density

Experiment #3. Density Experiment #3. Density Goals 1. To measure and calculate the density of various substances. 2. To use significant figures correctly in calculations. Background Density is the mass per unit volume of a

More information

Objective To determine the penetration value of an asphalt cement sample.

Objective To determine the penetration value of an asphalt cement sample. 2 Transportation Laboratory The grades of the asphalt cement depending on the penetration in 1/10 mm are: AC 20 30 ( hard & not effect with temperature ) used for inclined planes due to its high viscosity.

More information

CORESTA Recommended Method No. 57

CORESTA Recommended Method No. 57 Cooperation Centre for Scientific Research Relative to Tobacco Tobacco and Tobacco Products Analytes Sub-Group CORESTA Recommended Method No. 57 DETERMINATION OF WATER IN TOBACCO AND TOBACCO PRODUCTS BY

More information

Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller

Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller University of California Cooperative Extension Fresno County Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller Harvest season will soon be upon us in the San Joaquin Valley,

More information

DETERMINATION OF DENSITY

DETERMINATION OF DENSITY DETERMINATION OF DENSITY Dr. Barbara B. Bunn. Adapted from Experiments in General Chemistry ; Wiley 1996J.G. Wardeska, T.T-S. Huang, R.W. Kopp; used by permission. Tested by Ms. Janice Orr s Chemistry

More information

SOLIDS: Mass, Volume and Density Measurements

SOLIDS: Mass, Volume and Density Measurements CHEM 1411 Lab Solids: Mass, Volume, and Density 23 SOLIDS: Mass, Volume and Density Measurements A. Overview Review Sections 1.4-1.6 in your textbook (Chemistry: The Central Science, 9th Ed., Brown, LeMay,

More information

Investigating Photosynthesis Using Algal Balls

Investigating Photosynthesis Using Algal Balls Investigating Photosynthesis Using Algal Balls Safety Notes: There are no harmful chemicals in this investigation if handled appropriately Apparatus Beaker (100 or 250 ml) with 50-100ml calcium chloride

More information

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST Aim: To determine the workability of concrete by Slump test as per IS : 1199-1959 Mould - in the form of the frustum of a cone having the following

More information

Enzyme Activity Lab. Grade 12 University Preparation Biology. Performed By:

Enzyme Activity Lab. Grade 12 University Preparation Biology. Performed By: Enzyme Activity Lab Grade 12 University Preparation Biology Performed By: Due: Foreword This laboratory involves the use of an enzyme that will react with hydrogen peroxide. The enzyme is catalase and

More information

Sephacryl S-100, S-200, S-300, S-400, S-500 High Resolution

Sephacryl S-100, S-200, S-300, S-400, S-500 High Resolution GE Healthcare Sephacryl S-100, S-200, S-300, S-400, S-500 High Resolution Instructions Sephacryl 2 Instructions 52-2086-00 AK Contents 1. Introduction 5 2. To prepare the medium suspension 6 3. To pack

More information

Purification Of A Solid By Recrystallization AND Identification By Melting Point Determination

Purification Of A Solid By Recrystallization AND Identification By Melting Point Determination Purification Of A Solid By Recrystallization AND Identification By Melting Point Determination Refer back to your recrystallization and melting point experiments. In this experiment you must purify your

More information

Unit-2. Properties of Matter. Solutions 2.1 Matter & Density page V 1 =4.3.6=72 cm 3. Volume of the removed triangular prism (V 2 )

Unit-2. Properties of Matter. Solutions 2.1 Matter & Density page V 1 =4.3.6=72 cm 3. Volume of the removed triangular prism (V 2 ) 2.1 & Density page - 61 1. A solid object is given in the figure. Volume of the rectangular prism (V 1 ) V 1 =4.3.6=72 cm 3 Volume of the removed triangular prism (V 2 ) V 2 =((2.3)/2).6=18 cm 3 What is

More information

Method 5.2 Syrup and remelt: Brix, NIR pol and purity

Method 5.2 Syrup and remelt: Brix, NIR pol and purity Section 5: Syrup and remelt p 1/5 Method 5.2 Syrup and remelt: Brix, NIR pol and purity 1. Rationale This method is applicable to factory syrups and remelt and may be used to obtain data for factory control

More information

Information about your KERN test weights

Information about your KERN test weights Test weights Weights yesterday and today Weights have always been used to carry out weighing procedures. This original purpose has almost disappeared. Today, weights are used almost exclusively for adjusting

More information

(aq) + 5e - Mn 2+ (aq) + 4H 2

(aq) + 5e - Mn 2+ (aq) + 4H 2 EXPERIMENT 20 Titrimetric Determination of Iron INTRODUCTION Potassium permanganate is widely used as an oxidizing agent in titrimetric analysis. In acidic solution, a permanganate ion undergoes reduction

More information