Multi-Pole Toggle Switches
|
|
- Lynne Hunter
- 6 years ago
- Views:
Transcription
1 Page 1 of 5 > witches and Indicators > Toggle witches > Multi-Pole Toggle witches Multi-Pole Toggle witches McGill full-size double pole, 3 pole and 4 pole toggle switches are available in a variety of circuit arrangements and differe terminal types to meet your electrical requirements. Metallic toggle and threaded bushing ensure extended service life. Al switches are UL Recognized and CA Certified. pecifications 6, Double Pole 6A, 125V AC; 3A, 250V AC; 1/4 HP, V AC; 50/60 Hz uitable for 6A, 12V DC applications 15, Double Pole 15A, 277V AC; 3/4 HP, V AC uitable for 15A, 12V DC applications 17, 3 Pole and 4 Pole UL Recognized 17A, V AC; 1HP, 125V AC; 2HP, 250V AC 1, 2, or 3 phase uitable for 17A, 12V DC applications CA Certified 17A, V AC; 1HP, 125V AC; 2HP, 250V AC 1, 2, or 3 phase 6, Double Pole - While upplies Last 6A, 125V AC; 3A, 250V AC; 1/4HP, V AC, 50/60 Hz, uitable for 6A, 12V DC applications 6, Double older Pole /older te OFF DPT , OFF DPDT ,
2 Page 2 of DPDT , () OFF () DPDT , () OFF DPT , () DPDT , OFF () DPDT , , Double Pole 15A, 277V AC; 3/4HP, V AC, uitable for 15A, 12V DC applications 15, Double Pole Term OFF DPT OFF DPDT DPDT () OFF () DPDT () OFF DPT () DPDT OFF () DPDT (OFF) DPT , Double Pole - While upplies Last 15A, 277V AC; 3/4HP, V AC, uitable for 15A, 12V DC applications 15, Double Pole - While upplies Last older -- OFF DPT OFF DPDT DPDT () OFF () DPDT () -- OFF DPT #1 te # () DPDT
3 Page 3 of 5 OFF () DPDT (OFF) -- DPT , 3 Pole 17, 3 Pole Termin -- OFF 3PT () -- OFF 3PT OFF 3PDT PDT () 3PDT OFF () 3PDT () OFF () 3PDT , 3 Pole - While upplies Last 17, 3 Pole - While upplies Last OFF 3PT () OFF 3PT (OFF) 3PT OFF 3PDT PDT () 3PDT OFF () 3PDT () OFF () 3PDT 3022 older #1 te #2 te A
4 Page 4 of 5 17, 4 Pole 17, 4 Pole Termin -- OFF 4PT () -- OFF 4PT OFF 4PDT PDT () 4PDT OFF () 4PDT () OFF () 4PDT , 4 Pole - While upplies Last 17, 4 Pole - While upplies Last OFF 4PT () OFF 4PT (OFF) 4PT OFF OFF 4PDT PDT () 4PDT OFF () 4PDT () OFF () 4PDT 4022 older #1 te #2 te A Dimensions witch eries Bushings Bats Case 1121, 0121 eries 15/32"- 32 thread 15/32" long 9/16" long 1 15/64" x 51/ 0140 eries 15/32"- 32 thread 15/32" long 9/16" long 1 5/16" x 15/3 te: Mounting hardware and terminal screws (where applicable) furnished unassembled. Mounting hardwar
5 Page 5 of 5 consists of one plated hex nut and knurl nut. Indicating plate is also furnished for maintained -OFF curcuits McGill Electrical Product Group 9377 W. Higgins Road Rosemont, IL sales@mcgillelectrical.com
Distinctive Characteristics
Distinctive Characteristics Power and logic level capabilities available to suit varying applications. Light Duty Miniature Toggles Series E High torque bushing prevents rotation and separation from metal
More informationGeneral Specifications
Series M Process Sealed Miniature Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated PB Pushbuttons Rockers General Specifications Electrical Capacity
More informationDistinctive Characteristics
istinctive Characteristics Choice of long or short toggles in translucent colors combine with bright LEs available in red, amber, and green, plus super bright LEs available in white, green, and blue. Black
More informationDistinctive Characteristics
istinctive Characteristics ully Illluminated Toggles Series TL Choice of long or short toggles in translucent colors combine with bright LEs available in red, amber, and green, plus super bright LEs available
More informationFeatures SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S
Type List Terminal style Quick terminal Contact form Designation Features A general purpose Power Relay. Contact rating up to 12A 250VAC (). Epoxy sealed type and flux free. Quick connect terminal or PCB
More informationFeatures. Type List. Standard Type
SONG CHUN Features /2 general purpose Power Relays. SPDT, DPDT, TPDT contact configurations. DC & C coils are both available. Optional for flange covers, tapped core w/anti-rotation tab, indicator lamp,
More informationGeneral Specifications
ully Illuminated Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated PB Pushbuttons Rockers General Specifications Electrical Capacity (Resistive Load)
More informationVibranivo Mononivo. Series VN 4000 MN Series. Instruction manual
Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de
More informationPrevious Page Return to Index Next Page
Previous Page Return to Index Next Page http://www.switchcraft.com/products/jack-107.html (1 of 8) [2/13/2005 2:31:54 PM] 3.5 mm SINGLE MONO AND STEREO JACKS 1. 35RAPC4BV4 2. 35RAPC2AV 3. 35RAPC2BHN2 4.
More informationINSTRUCTION BOOKLET FOR PALLET DECOILER
INSTRUCTION BOOKLET FOR PALLET DECOILER MODEL: 1200, 3500, 5000, 6000, 7500, 8500, 10M, 12M, W-1000, W-2000, W-3500 & W-5000 200 Circuit Drive North Kingstown, Rhode Island 02852 USA International Phone:
More informationPump Specifications 450 Series 1/2 hp Submersible Sump Pump
Pump Specifications 450 Series 1/2 hp Submersible Sump Pump 450_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 450-Series Dimensional
More informationBulletin Grounding and bonding of solar photovoltaic systems Rules , , , and
Bulletin 64-2-0 Grounding and bonding of solar photovoltaic systems Rules 64-064, 64-066, 64-068, 64-070 and 64-222 Scope (1) Introduction (2) Grounding of solar photovoltaic system output, ac grounding
More informationDUPLEX INSTALLATION. Customer provides single service lateral attachment point in trough.
DUPLEX INSTALLATION A. GENERAL NOTES: The device shown may be used when the inspection authority having jurisdiction requires the installation of a service disconnecting means adjacent to the meter. MPC
More informationCHAPTER 13 GROUNDING AND BONDING
GROUNDING AND BONDING CHAPTER 13 GROUNDING AND BONDING Grounding and bonding must be in accordance with Article 250 of the National Electrical Code (NEC). Bonding is defined in the NEC as the permanent
More informationOPO-SHORT Installation Instructions Manual Version
10200 South Kedzie Avenue Evergreen Park, IL 60805 800.499.0400 708.499.0400 Fax 708.499.4620 OPO-SHORT Installation Instructions Manual Version OPO-1S, OPO-3S, OPO-4S PreSell Main Board (shown as Standard
More informationDifferential Pressure Pressostat
Differential reure reotat Swi baed Trafag i a leading international upplier of high quality enor and monitoring intrument for meaurement of preure and temperature. Application Shipbuilding Engine manufacturing
More informationMetering Installations for Mobile Homes or Mobile Home Parks:
Metering Installations for Mobile Homes or Mobile Home Parks: Overhead Installations The metering pole must be a minimum of 17 ft, Class 5 pole set at least 4 ft deep so that it will be of sufficient height
More informationonlinecomponents.com
FSPDB FSPDB IP20 Finger Safe Power Distribution Block Reference Designation Nb. wire Nb. wire Materials Pckg inlets outlets X232803C FSPDB4A 335A 1/1 16 to 185mm 2 1x 185mm 2 to 16mm 2 1x 185mm 2 to 16mm
More informationVSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING
Flows to 200 GPM. TDH to 95 Feet at 1750 RPM Free Standing or Guide Rail Design. Available in Standard Submersible or Explosion Proof Design. Provided with 25 feet of submersible motor power cable. Cast
More informationMechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G
Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree
More informationPRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.
PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts
More informationSwitch Rack Assemblies
Switch Rack Assemblies Applications: Free-standing switch rack assemblies are used: To provide a complete motor control center in one integrated package Outdoors and indoors In damp, wet or corrosive locations
More informationSECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number
MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and
More informationSPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building
2004 Specifications CSJ 0720-03-095 SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building 1. Description. Furnish and install Environmentally Controlled Communications Building
More informationGBC Fusion Punch Offset fset Stacker Parts Manual
GBC Fusion Punch Offset fset Stacker Parts Manual Revsion: Internal Release March 6, 00 :00 PM J Daniels Part number: 760 GBC National Service 00 Bond Street Lincolnshire, IL 6006 Ph: (00) 70-777 Fax:
More information3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white
3-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A a b c d e f a c (cont d) e (cont d) f (cont'd) Protection Rating
More informationDUST FREE ACTIVE Total Home Air Purification
DUST FREE ACTIVE Total Home Air Purification Installation & Operation Manual This manual covers the following models: DF ACTIVE 6" - #13070 DF ACTIVE 12" - #13071 GENERAL This device is designed to be
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2015-12-22 Page 1 of 13 Report Reference # E182560-V4-S35 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment
More informationHALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel
HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ
More information37-SDMS-01 REV. 03 SPECIFICATIONS FOR
37-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE MOLDED CASE CIRCUIT BREAKERS FOR SERVICE CONNECTIONS This specification is property of SEC and subject to change or modification without any notice CLAUSE
More informationHALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel
HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More informationGEMINI G9 PHOTOVOLTAIC RACKING SYSTEM
Installation Instructions GEMINI G9 PHOTOVOLTAIC RACKING SYSTEM SYS TEM DISTRIBUTED BY: RENEWABLE SALES 16 EVERETT ST HOLLISTON MA 01746 508-309-4437 INFO@RENEWABLESALES.COM GEMINI G9 PV RACKING SYSTEM
More informationHS h e n EU omplia t 2002 / 9 5 / C
9 57-30500 0 0 E U 2 C A mp hen 2/ 5 / E omplia Ro HS ol C nt hen z n She 57-30360 DE-09P & DE-09S Standards: UL File: E119881 Connectors according to MIL C24308 SPECIFICATIONS : MATERIALS AND Shells Steel
More informationSection 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2
Section 2 Index Model Metal Sheath and Ceramic Thermocouple Assemblies Page I1 GTAW Welded Hex Nipple w/ Head 2-1 I2 Spring Loaded Hex Nipple w/ Head 2-2 I3 Spring Loaded Pipe Nipple w/ Head 2-3 I4 Nipple-Union-Nipple
More informationNo. F ISSUED: Apr. 7, 2009 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AWA MODEL
No. F022-3207 ISSUED: Apr. 7, 2009 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KMD-201AWA S LIST (GENERAL) U-1 APR. 2009 V-0 JAN. 2010 V-1 FEB. 2010 V-2 JUL. 2010 A-0 JAN. 2011 A-1 APR.
More informationSECTION EARTHING AND EARTH FAULT PROTECTION
SECTION 16660 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the construction and assembly of a complete electrical earthing
More informationLow/Medium Capacity Rockers Series SW
Low/Medium Capacity ockers Series SW GENEAL SPECIFICATIONS FO SW000s (esistive & Inductive Load) Other atings Power Level: Shown in the following tables Contact esistance: 0 milliohms maximum Insulation
More informationThermocouple Reference Table
Thermocouple is the description for electrical feedthroughs that are commonly used for temperature measurement systems. A thermocouple feedthrough does not measure temperature, but rather it is used to
More informationPRE-INSTALLATION GUIDE
TRUMPF MEDICAL SYSTEMS Inc. Charleston, SC PRE-INSTALLATION GUIDE FOR CEILING MOUNTED EQUIPMENT MANAGEMENT SYSTEMS, SURGICAL / EXAM LIGHTS, AND FLAT PANELS EMS and Light Pre-installation Guide File: 110720
More informationPRICE LIST NO. 12 VH SERIES
PRICE LIST NO. 12 VH - 508 SERIES Bed ----------------------------------------Flame hardened bed ways Centre Height ---------------------------508 m.m. (20") Width of bed ----------------------------610
More information400 watt, high pressure sodium. Type C watt, high pressure sodium Collector Street Light Units
CITY OF MEDFORD PUBLIC WORKS DEPARTMENT ENGINEERING & DEVELOPMENT DIVISION TRAFFIC ENGINEERING SECTION April 15, 2010 Street Lighting Standards and Specifications Luminaire Types Type R-100 100 watt, high
More informationLUBRICATION PUMP Z2 CENTRAL LUBRICATION
LUBRICATION PUMP APPLICATION Lubrication pumps are used as a source of pressure lubricant in the circuits of two-line central lubrication systems. Pumps can be used for lubrication of high number of lubricated
More information443C. Parts Manual. MM Rev. 05 (06 93)
443C Parts Manual MM294 578-748 Rev. 05 (06 93) This manual is furnished with each new TENNANT Model 443C. This manual consists of the Standard Parts; Options; Breakdowns; and Cross Reference sections.
More informationTip Jacks. Johnson Components P.O. Box 1732 Waseca, MN Fax:
.060" (1.5 mm) Shrouded Tip Jack (Solder or Crimp) 5.060" (1.5 mm) Uninsulated Tip Jack (Solder or Crimp) 5.060 (1.50) Shrouded Tip Jack (Solder or Crimp) 5.060 (1.50) Uninsulated Tip Jack (Solder or Crimp)
More information1993 Specifications CSJ SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets
1993 Specifications CSJ 0331-04-050 SPECIAL SPECIFICATION 4880 Bridge Equipment Cabinets 1. Description. This Item shall govern for furnishing and installation of Equipment Cabinets for the Bridge Collapse
More informationGMV Super Star. Part List
GMV Super Star Part List 25 Table of Contents Part List 25 Magazine... 28 Target Retainer... 30 Throwing Table... 31 Main Frame... 32 Turntable... 33 Base... 34 Elevator... 35 Throwing Arm... 36 Motor...
More informationINSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS
INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using
More informationOperating Instructions
Operating Instructions Series B37000 Hose Reels BB37118 L CB37118 L EB37118 L12D BB37122 L CB37122 L EB37122 L12D BB37128 L CB37128 L EB37128 L12D Dimensional Data C A B D Part # A B C D BB/CB37118 L 31
More informationIndustrial Thermocouples
Industrial Thermocouples Industrial thermocouples are used in high temperature applications, such as those listed below. Several calibrations are available as well as various mechanical configurations.
More informationHigh Temperature Pressure Sensor
Pressure High Temperature Pressure Sensor for Gas Turbine- and Thermoacoustics Applications Differential, acceleration compensated, piezoelectric pressure sensor for operation temperatures up to 700 C.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB #
SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE
More informationPUSH BUTTONS A 1 E C 1 SERIES 5A AGENCY APPROVALS SPECIFICATIONS
AGENCY APPROVALS SPECIFICATIONS Snap acting pushbutton C File N E195524 File N E195524 Contact Rating: S (silver) - 1A @ 120 VAC or 28 VDC - A (gold) - 0.4 VA max @ 20 VAC or DC max - G (gold on silver)
More informationBulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators
Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...
More informationPNP Series Sealed Pushbutton Switch
Sealed Switch Features/Benefits IP68 sealed to endure harsh environments,000,000 life cycle Longer solder leads for ease of wire installation Multiple housing styles Up to 5 resistive load Wirelead options
More informationAREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index SECTION 14 - ELECTRICAL DEVICES, FOUNDATIONS, HARDWARE
SECTION 14 - ELECTRICAL DEVICES, FOUNDATIONS, HARDWARE 14.1 Recommended Wire Connectors, Terminals 14.1.1 37-2 Recommended Design Criteria and Functional/Operating Guidelines for Solderless Crimp-Type
More informationSignal Framework. Side Pole Post Top Overhead Mast Arm Pedestrian Pipe Fittings Pole Hardware Special / Custom. Signals. Overview.
Signal Framework Side Pole Post Top Overhead Mast Arm Pedestrian Pipe Fittings Pole Hardware Special / Custom Cabinets Controllers Signals Signs Software Specialty Overview McCain s Signal Framework collection
More informationINSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.
INSULATION GUARD MEG-1000 (Code 2 28 981) INSTRUCTION MANUAL ( M 981 220 / 99A ) (c) CIRCUTOR S.A. ----- Insulation guard MEG-1000 -------- M - 981 220 --- Page nº 1 Insulation guard MEG-1000 1.- BASIC
More informationMaterial/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating
3 LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. eatures Intermateability UL Listed and CSA Certified interchangeability
More information2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical
ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2015-09-28 Page 1 of 10 Report Reference # E182560-V4-19 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment
More informationGeneral Specifications
General Specifications Electrical Capacity (Resistive Load) Power Level (silver): @ V C or @ 0V C Logic Level (gold): 0.4V maximum @ 8V C/DC maximum (pplicable Range 0.m ~ 0. @ 0mV ~ 8V) Logic/Power Level:
More informationSECTION LUMINAIRES AND ACCESSORIES
SECTION 16500 LUMINAIRES AND ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to
More informationConstruction Heater. Pilot Light and Electronic Ignition. Parts Identification Guide
Construction Heater Pilot Light and Electronic Ignition Parts Identification Guide 150-608 Table of Contents PARTS IDENTIFICATION GUIDE Tradesman Portable Forced Section/Page CP100C..............................................................1.
More information1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.
SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2
More informationOVERHEAD SERVICES - SECONDARY
OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...
More informationINSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS
INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS Publication No. US-NEBS-IM-003 September 2013 INSTRUCTIONS for ASSEMBLING NEBS FLOODED RACKS Read all instructions carefully and observe all warnings before
More informationTerminals: Terminals BTI-15. Specifications. Elcom International Pvt. Ltd. C-DOT, LCSO Approved. Panel Mounting
Terminals BTI-15 C-DOT, LCSO Approved Panel Mounting Screw-type Mounting: Front Panel Thickness: 3.0 max. Test Specification: JSS 52710(1994) TYPE TSC - 10 - N. Product App. Weight(Max): 12.0 gms Polyamide
More information10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!
10810 W. LITTLE YORK RD. #130 - HOUSTON, TX 77041-4051 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A
More informationHRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS
HRI-R22t series GENERAL HRI-R22t series The device has similar characteristics of previous model but it s more cheap and it has less functions. There is measuring signalling and it is able to verify temperature
More informationBulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators
Bulletin F Product Overview Bulletin F Plastic and Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Description Page Specifications...
More informationInstallation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02
Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380
More informationStainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K
T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces
More informationSECTION SECONDARY UNIT SUBSTATIONS
SECTION 26 12 16 SECONDARY UNIT SUBSTATIONS PART 1 GENERAL 1.1 SUMMARY This section describes metal-clad, indoor or outdoor, secondary unit substations with integral primary fused disconnect switches,
More informationAnti Vandal Pushbutton, Single Pole. Anti Vandal Pushbutton, Single Pole
Anti Vandal Pushbutton, Single Pole S76.287 (7.3) c: Screw (Assembled).098 (2.5) Typ NEW g 54 377 SPST NO OFF (ON) Stainless Steel, Flat S76b 54 378 SPST NO OFF (ON) Stainless Steel, Curved S76c 54 378E
More informationSECTION CONDUITS AND BOXES
PART 1 GENERAL 1.01 DESCRIPTION A. Work covered by this section includes the furnishing and installation of conduits and boxes and the testing of the completed electrical systems 1.02 SUBMITTALS A. The
More informationWilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification
Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps Engineering Specification PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install horizontal multi-stage, high pressure, self priming pressure
More informationCERTIFICATE OF COMPLIANCE
UL CERTIFICATE CERTIFICATE OF COMPLIANCE Certificate Number 20160606-E472978 Report Reference E472978-20160217 Issue Date 2016-JUNE-06 Issued to: Blue Point Fasteners 14728 Yorba CT Chino, CA 91710 This
More informationITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)
ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL) 686.1. Description. This Item shall govern for designing, fabricating, furnishing and erecting steel traffic signal pole assemblies of the various types
More informationKEEP FOR FUTURE REFERENCE MRT FORKLIFT ADAPTER READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT
KEEP FOR FUTURE REFERENCE P.O. Box 368 908 West Main Laurel, MT USA 59044 phone 800-548-7341 phone 406-628-8231 fax 406-628-8354 INSTRUCTIONS International Version STOCK NUMBER: 95722 MRT FORKLIFT ADAPTER
More informationTABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4
TITLE SPECIFICATION FOR FREE- STANDING 11 DATE: AUGUST 2006 PAGE: 1 OF 15 TABLE OF CONTENTS Page FOREWORD... Error! Bookmark not defined. INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DRAWING...4 4
More informationPERFORMANCE SPECIFICATION SHEET
INCH-POUND PERFORMANCE SPECIFICATION SHEET MIL-PRF-28777F 23 June 2003 SUPERSEDING MIL-PRF-28777E 8 July 1996 RELAYS, HYBRID, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE COIL OPERATE
More informationSECTION STAINLESS STEEL FLEXIBLE MESH PLANT SUPPORT SYSTEM. Show hidden Specifier Notes for best results
SECTION 32 94 00 STAINLESS STEEL FLEXIBLE MESH PLANT SUPPORT SYSTEM Show hidden Specifier Notes for best results PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Stainless Steel Wire Rope Assemblies
More informationBUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466
BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein
More informationW-P-115C March 14, 1990 SUPERSEDING W-P-115B June 8, 1984 FEDERAL SPECIFICATION PANEL, POWER DISTRIBUTION
March 14, 1990 SUPERSEDING W-P-115B June 8, 1984 FEDERAL SPECIFICATION PANEL, POWER DISTRIBUTION This specification is approved by the Commissioner, Federal Supply Service, General Services Administration,
More informationSpecifications 9-Inch 10-Inch
Specifications 9-Inch 10-Inch General Mineral Tank Size 9x48 in. (229x1,219mm) 10x54 in. (254x1,372mm) Control Hi-Flo Power Valve Hi-Flo Power Valve Timer Electronic Electronic Temperature Limits 33-120
More information3BT / 4BT Series Tiny Stat Hermetic Thermostats, -18 C to 177 C, SPST
3BT / 4BT Series Tiny Stat Hermetic Thermostats, -18 C to 177 C, SPST FEATURES Smallest snap-acting thermal switches on the market today Single Pole / Single Throw (SPST) Preset temperature set points,
More informationDESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7
DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification
More informationSECTION SIGNAL SYSTEMS MISCELLANEOUS PRODUCTS
SECTION 18360 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for miscellaneous components and products for signal systems. 1.02 REFERENCE STANDARDS A. American National Standards Institute
More informationRepair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL
SECTION 16601 LIGHTNING PROTECTION SYSTEM PART 1 GENERAL 1.1 SCOPE A. Furnish and install all materials and labor required to provide a complete functional lightning protection and common ground system
More informationThermocouple Reference Table
Thermocouple is the description for electrical feedthroughs that are commonly used for temperature measurement systems. A thermocouple feedthrough does not measure temperature, but rather it is used to
More information50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens
50 Watt Low Bay LED Light Fixture - Outdoor Rated - IP67-4,333 Lumens Part #: GAU-HB-50LED-RT Page: 1 The Larson Electronics GAU-HB-50LED-RT Low Bay light fixture provides operators with a powerful and
More informationSeismic Products Seismic Cabinets
Spec-01178 Seismic Products Seismic Cabinets Seismic Free-Standing, Dual-Access Cabinet, Type 12 SPECIFICATIONS 12 gauge steel construction Seams continuously welded and ground smooth; no holes or knockouts
More informationTEMPORARY METER POLE INSTALLATION
TEMPARY METER POLE INSTALLATION MEMBER PROVIDED Location to be made by REMC within 50' of our transformer or existing service Temporary pole to be properly braced 24" 3 wire weatherhead (located 24" from
More informationPERFORMANCE SPECIFICATION SHEET
INCH-POUND MIL-PRF-39016/53C 27 April 2006 SUPERSEDING MIL-R-39016/53B 20 July 1988 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, HERMETICALLY SEALED, 4PDT, LOW LEVEL
More informationInlet Duct System for a Cisco 6807 Part Number: DIRLC3210S17W
Inlet Duct System for a Cisco 6807 Part Number: DIRLC3210S17W Panduit Corp. 2014 INSTALLATION INSTRUCTIONS For a Panduit N-Type Cabinet Inlet Duct Component Guide Note: Upper RH Has Notches On Top. Upper
More informationALTERNATOR. LSA 36 - single-phase to 11.5 kva
3692 en - 2009.07 / f ALTERNATOR LSA 36 - single-phase - 3.5 to 11.5 kva LSA 36 ALTERNATOR Developed using special modelling software to give optimised electrical performance Designed to supply power to
More informationField case for temperature transmitter Model TIF11
Electrical temperature measurement Field case for temperature transmitter Model TIF11 WIKA data sheet TE 62.02 Applications Plant construction Process engineering General industrial applications Energy
More informationALUMINUM OR IRON CONDUIT BODIES
7 SERIES ALUMINUM OR CONDUIT BODIES LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Features Intermateability UL Listed
More information