BANK OF INDIA. TENDER DOCUMENT PART B (Financial Bid) Last Date of submission of Tenders: BOQ

Size: px
Start display at page:

Download "BANK OF INDIA. TENDER DOCUMENT PART B (Financial Bid) Last Date of submission of Tenders: BOQ"

Transcription

1 BANK OF INDIA ELECTRICAL & DATA CABELING WORK OF CHANDIGARH SME CITY CENTRE/ BRANCH/ZONAL OFFICE OF BANK OF INDIA AT SCO 76-82, SECTOR 31-A, CHANDIGARH TENDER DOCUMENT PART B (Financial Bid) Last Date of submission of Tenders: Consisting of : Tender Document 1. BOQ NOTE: All conditions, rules, instructions specifications and any other information in part A is for the purpose of governing Part B. Both Part A and Part B along with all Drawing constitute the full and complete Tender Document ARCHITECT: THE DESIGN FORUM 2 nd FLOOR, S.C.O-11, SECTOR-26, CHANDIGARH PHONE : MOBILE: Client: Bank of India Zonal Office S.C.O : 76-82, Sec-31A, Chandigarh

2 RECOMMENDED MAKE TO BE USED FOR THE ELECTRICAL & DATA CABELING WORK OF SME CITY CENTRE/ BRANCH/ZONAL OFFICE OF BANK OF INDIA AT SCO 76-82, SECTOR 31- A, CHANDIGARH 1. MCB : Indo Asian / Havell.s / L & T / Clipsal / Schinder. 2. Change over switch : L & T 3. Modular Switch : Anchor Roma / MK / NorthWest 4. Wires / cables : Anchor/ Finolex / Polycab 5. Ceiling fans : Bajaj / Khaitan. 6. Exhaust fans : Bajaj / Khaitan. 7. Wall mounted fan : Bajaj / Khaitan. 8. Ordinary tube light ( Single ) : Philips / Wipro (model specified in BOQ) 9. Tube light fixtures ( Double ) : Philips / Wipro (model specified in BOQ.) 10. 3X36 w recessed fixture : Philips / Wipro (model specified in BOQ) v, 50w halogens : Philips / Wipro (model specified in BOQ). 12. MCCB : Indo Asian / Havell / L & T / Clipsal / Schinder. 13. ELCB : Indo Asian / Havell / L & T / Clipsal / Schinder. 14. Telephone wire : Anchor / MK / NorthWest 15. Main panel : Anchor 16. Isolator : Havell s 17. LAN Cable (Cat 5) : D-Link 18. I/O Switch : D-Link All other Materials shall be best quality heavy section mentioned in the drawing as well as in bill of quantities and also approved by Bank / Consultant. 2

3 BOQ FOR THE ELECTRICAL & DATA CABELING WORK OF SME CITY CENTRE/ BRANCH/ ZONAL OFFICE OF BANK OF INDIA AT SCO 76-82, SECTOR 31-A, CHANDIGARH S.NO. DESCRIPTION QTY UNIT RATE (ELECTRICAL WORK) (A) Light Wiring 1 Supply, installation, testing and commissioning of point wiring of light points / Fan points /6A socket outlets /16A sockets etc. using modular type accessories and PVC conduit pipe 2mm thick complete with all accessories like heavy duty junction boxes, PVC bends, pull boxes with PVC / Bakelite covers etc. The work scope cover cost of modular accessories, PVC pipe conduiting system on wall, false ceiling or concealed piping including wall chiseling, laying of conduits during slab casting, installation of conduits in wall with GI staples / saddles etc. included in scope of contractor. The tools and consumables like hacksaw blades, to be arranged by contractor. The job shall be inclusive of cutting the chases in the walls for conduit fixing and refilling the same up to brick level for final plaster matching by the civil contractor. Complete work has to be executed strictly as per drawing, specifications to ensure good aesthetics, line and level. The conduit shall be fixed on wall / slab at every 450mm distance by saddles. 3

4 a. Light point / wall fan / exhaust fan wiring using 2 No. 1.5mm2 PVC flexible copper wire 1100V grade for phase and neutral with 1 No. 1 mm2 PVC flexible copper wire for earth. i. 1 light point controlled by 1 No. 6A modular switch ii. Secondary light point wiring from existing light point with cost of wire and pipe etc. iii. 1 light point controlled by 2 Nos. 6A double control switch 70 Nos. 70 Nos. 10 Nos. 2 Supply, installation, testing and commissioning of circuit wiring of circuit / mains from light DB to switch board / inverter wiring and power wiring from DB to socket outlet using PVC conduit 2mm thick with all conduit accessories. The work scope covers conduiting system on walls, trusses, in racks or concealed including wall chiseling laying of conducts during slab casting, installation of conduits in wall with saddle, cost of PVC copper conductor FRLS included in scope of contractor. The tools consumables required for this installation shall be (The conduit shall be provided with GI saddles at every 450mm distance complete work has to be executed strictly as per drawing and specifications to ensure work as per standard and aesthetics. The job shall be inclusive of cutting the recess in the walls for conduit fixing and refilling the same upto brick level for final plaster matching by the civil contractor.) 4

5 a. 2 No. 2.5sqmm PVC flexible 180 Mtr copper wires for phase and neutral with 1 No. 1sqmm PVC flexible copper wire for earth (for circuit wire). b. 2x6 mm2+1x2.5 mm2 Copper 180 Mtr wires (for UPS DB supply) 3 Supply, Installation, testing and commissioning of switchboards in sheet metal housing and consisting of modular plate type ingredients i.e. switches, plug sockets etc. as detailed below including MS modular box and plate. The board may be concealed in wall or exposed mounted on wall / mounted on wiring race way of furniture module, partition etc. In case of race way, slot cutting in race way for mounting of switch plates shall be included in the scope of work. i. Powerpoint having 16A 6 pin socket and 16A switch modular type with modular sheet and copper wiring with 2x2.5sqmm PVC Copper wire + 1x1.5sqmm copper earth wire from DB to powerpoint with cost of PVC conduit. ii. Light plug having 6A 5 pin socket and 6A switch modular type with modular sheet and copper wiring with 2x2.5sqmm PVC Copper wire +1x1.5sqmm copper earth wire from DB to light plug with cost of PVC conduit (3 light plugs can be looped in one circuit). 15 Nos. 55 Nos. 5

6 iii. A.C. point having 25A 6 pin 7 Nos. socket and 25A switch modular type with modular sheet and copper wiring with 2x4sqmm PVC Copper wire 1x2.5sqmm copper earth wire from DB to A.C. point with cost of PVC conduit. (B) FIXTURES 4 Erection, testing & commissioning of box type fitting / CFL fitting / mirror optical fitting complete with Cu wound choke, CFL lamp / energy saving tube rod T-5, directly on wall / in false ceiling / embedded in RCC roof with screws etc. and making connections with cost of PVC Cu connection wire, screws etc. The job includes cost of cutting of false ceiling also. a. Supply & Installation of directindirect recessed mounted luminaries with 2No. of 36W PL Tube ( - Wipro make -Crescent ) b. Supply & installation of 2x18W round down lighter fittings with PL tubes recessed in false ceiling (Wipro make ) c d 1x28W T-5 wall mounted tube light with 28W tube rod fixed on wall/ceiling Wipro make 2x28W T-5 wall mounted tube light with 28W tube rods fixed on wall/ceiling Wipro make. 25 Nos. 30 Nos. 40 Nos. 50 Nos. 6

7 5 Supply & installation of wall 20 Nos mounted fan 16" sweep with acrylic blades oscillating type with built-in regulator. The fan is to be fixed on wall with suitable screws. 6 Supply and installation of exhaust fan with louver shutter. The exhaust fan is to fixed in existing ventilator with suitable fixing a. 15" sweep 6 Nos b. 12" sweep 6 No 7 Supply and installation of 1C x 6sqmm copper insulted 1.1kv grade unarmored conductor through 20mm metal conduit for earth pit to UPS room 100 Mtr 8 Supply, installation testing and commissioning of 0.5mm size tinned copper conductor 20 pair PVC insulated telephone in existing PVC conduit / in workstation recessed in wall / on surface as required complete with accessories. (including end termination) a. 20 pair in PVC conduit 40 Mtr b. in workstation recessed in wall / 30 Pts. on surface as required (Supply and fixing in position telephone socket Jack type modular RJ-11, with shutter in suitable modular MS box with modular plate recessed in wall) 9 Providing & laying of networking cable (D-Link make) CAT Mtr 7

8 10 Supply & fixing in position computer 40 Nos. outlet RJ- 45 modular type complete with modular plate and MS box recessed in wall. 11 Supply and installation of 24 port unmanaged switch 10/100 MBPS of D- Link make. 1 Nos. 12 Supply and installation of 24 port jack panel of D Link make. 1 Nos. 13 Supply & installation of 9 U mounted rack 18 height made of power coated MS sheet of D link make 1 Nos. TOTAL FOR (ELECTRICAL WORK) Discount if any Net Total Net Total in Words (Seal & Signature of Contractor) 8

BOQ FOR ELECTRICAL & LAN CABLING WORKS FOR BANK OF INDIA AT THALTEJ BRANCH, AHMEDABAD.

BOQ FOR ELECTRICAL & LAN CABLING WORKS FOR BANK OF INDIA AT THALTEJ BRANCH, AHMEDABAD. BOQ FOR ELECTRICAL & LAN CABLING WORKS FOR BANK OF INDIA AT THALTEJ BRANCH, AHMEDABAD. ARCHITECT : CREATION ARCHITECTS, AHMEDABAD NO. DESCRIPTION QTY UNIT RATE AMOUNT 1 M.V. DISTRIBUTION BOARDS & POWER

More information

Mayur Shah And Associates Architects, Interior Designer And Turnkey Consultants. project: B.O.I - SAMARKHA BRANCH

Mayur Shah And Associates Architects, Interior Designer And Turnkey Consultants. project: B.O.I - SAMARKHA BRANCH BILLS OF QUANTITY - ELECTRICAL AND ALLIED WORK, FOR PROPOSED DESIGN OF SAMARKHA BRANCH, BANK OF INDIA, RO VADODARA. NOTE : ALL CHARIS OR CHASES IN WALLS / COLUMNS / SLABS MADE BY THE ELECTRICAL CONTRACTOR

More information

TENDER NOTICE No. 04/ TENDER DOCUMENT FOR ELECTRICAL WIRING FOR THE OFFICE OF GM & DGM, TELECOMMUNICATION, OPTCL, MERAMUNDALI.

TENDER NOTICE No. 04/ TENDER DOCUMENT FOR ELECTRICAL WIRING FOR THE OFFICE OF GM & DGM, TELECOMMUNICATION, OPTCL, MERAMUNDALI. TENDER NOTICE No. 04/2015-16 TENDER DOCUMENT FOR ELECTRICAL WIRING FOR THE OFFICE OF GM & DGM, TELECOMMUNICATION, OPTCL, MERAMUNDALI. General Manager, Telecommunication Circle, OPTCL, AT- 400/220/132kV

More information

BILL OF MATERIALS Name of the work: F.T.S Modernisation Work

BILL OF MATERIALS Name of the work: F.T.S Modernisation Work 1 BILL OF MATERIALS Name of the work: F.T.S Modernisation Work Erection,Testing and commissioning of Converter transformer 3 PH,11 KV/2 X 1800 V,4000 KVA outdoor Transformer size of 3150 L X 2800 D X 3200

More information

Mayur Shah And Associates Architects, Interior Designer And Turnkey Consultants. project: BOI- KHAMBHAT BRANCH

Mayur Shah And Associates Architects, Interior Designer And Turnkey Consultants. project: BOI- KHAMBHAT BRANCH BILLS OF QUANTITY - ELECTRICAL AND ALLIED WORK, FOR REDESIGN OF KHAMBHAT BRANCH, BANK OF INDIA,VADODARA ZONE NOTE : ALL CHARIS OR CHASES IN WALLS / COLUMNS / SLABS MADE BY THE ELECTRICAL CONTRACTOR FOR

More information

Delhi Public School Society

Delhi Public School Society Delhi Public School Society F-Block, East of Kailash, New Delhi-110065 RECORD NOTES OF Pre-BID MEETING ME:DPSS/HRDC-GN/1620 16th August, 2016 Project :- Construction of Human Resource Development Centre

More information

BILL OF QUANTITIES TALPUR HOUSE 2014

BILL OF QUANTITIES TALPUR HOUSE 2014 BILL OF QUANTITIES TALPUR HOUSE 2014 Electrical and Communication Work of Talpur House Phase-III. PLANNING & DEVELOPMENT DEPARTMENT... ENGINEERING & SERVICES SINDH MADRESSATUL ISLAM UNIVERSITY Aiwan-e-Tijarat

More information

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.

More information

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work Creation of Three clean area rooms (Master Mix, Amplification and Hybridization rooms) for Line Probe Assay with two

More information

Tender No. : GAIL/PA14/51603/ /RK [E-Tender Bid Invitation No ]

Tender No. : GAIL/PA14/51603/ /RK [E-Tender Bid Invitation No ] 1.1 SCHEDULE OF RATES SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 8A RATING, MMO VERTICAL ANODE BED: Supply, installation, testing and commissioning of 8 A rating, MMO tubular anode in vertical type

More information

Subject: Quotation for Renovation of Computer Labs in Sindh and Baluchistan.

Subject: Quotation for Renovation of Computer Labs in Sindh and Baluchistan. REQUEST FOR QUOTATION (RFQ) FACSIMILE/EMAIL Company/Individual Name: Business address: Telephone Fax Email Subject: Quotation for Renovation of Computer Labs in Sindh and Baluchistan. Dear Sir/Madam, On

More information

BOQ. Annexure-I. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No.

BOQ. Annexure-I. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No. Description of item Unit Quantity Rate (Rs.) Rate in words Amount(Rs.) Part-A: Civil works 1 Demolishing

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT ACTIVE COMPOSITE MILLS LTD. Dewan Idris Road, Zirabo, Ashulia, Savar, Dhaka, Bangladesh Factory List: 1. Active Composite Mills Ltd. Inspected by: Hemlal Report Generated

More information

Quotation Notice for installation of 20 Street Lights in Kaloor JLN Stadium premises

Quotation Notice for installation of 20 Street Lights in Kaloor JLN Stadium premises Quotation Notice for installation of 20 Street Lights in Kaloor JLN Stadium premises Kochi Metro Rail Ltd (KMRL), Invites quotation for Supply, Installation, Testing and Commissioning of decorative cast

More information

UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ. Original Issue Bamyan MAC Site Services - Phase 1 Bamyan, Bamyan, Afghanistan

UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ. Original Issue Bamyan MAC Site Services - Phase 1 Bamyan, Bamyan, Afghanistan UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ Original Issue Bamyan MAC Site Services Phase Bamyan, Bamyan, Afghanistan Project Components:. Site Services Phase NOTICE TO ALL BIDDERS COMPLETE

More information

Subject: Quotation for Renovation of Computer Lab in Sialkot, Lahore and Quetta.

Subject: Quotation for Renovation of Computer Lab in Sialkot, Lahore and Quetta. REQUEST FOR QUOTATION (RFQ) FACSIMILE/EMAIL Company/Individual Name: Business address: Telephone Fax Email Subject: Quotation for Renovation of Computer Lab in Sialkot, Lahore and Quetta. Dear Sir/Madam,

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

UNION BANK OF INDIA TENDER DOCUMENTS

UNION BANK OF INDIA TENDER DOCUMENTS UNION BANK OF INDIA ATM for Union Bank of India, Chethupet, Thiruvannamalai District. TENDER DOCUMENTS for Furnishing & Electrical Works. ARCHITECTS: M/S. KARTHIGEETA & ASSOCIATES ARCHITECTS, INTERIOR

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE

More information

A) Analysis of Rates for Decorative Pole (For DRG NO.-D/1/LTG/KMC) Page No.-3

A) Analysis of Rates for Decorative Pole (For DRG NO.-D/1/LTG/KMC) Page No.-3 A) Analysis of Rates for Decorative Pole (For DRG NO.-D/1/LTG/KMC) Page No.-3 a) 3.25 O.D.(80mm) G.I. Pipe (Jindal/Bansal make)medium Gauge =170 /39 =4.36mtrs say 4.5mtrs Including vat 4% @448.76/- = Rs

More information

Chapter - Six. Electrical Construction and Documentation

Chapter - Six. Electrical Construction and Documentation Chapter - Six Electrical Construction and Documentation 1 Electrical Contracting Works An engineering project in which electrical installation works include may be residential, public, commercial buildings;

More information

Estimate FOR THE SEPTIC TANK

Estimate FOR THE SEPTIC TANK Estimate FOR THE SEPTIC TANK S.NO ITEM DESCRIPTION. 1 Excavation in soil,soft & hard murum... Qty UNIT Rate Excavation for footing, machine foundation, plinth beams, wall footing, gutters,brick wall, tanks

More information

33 KV UG Cable Laying Work & Bay Extension Electrical Works - SBI

33 KV UG Cable Laying Work & Bay Extension Electrical Works - SBI 33 KV UG Cable Laying Work & Bay Extension Electrical Works - SBI ABSTRACT S.No Description Amount 1 33KV Bay Extention (132/33KV SS at RC Puram & Gachibowli ) (A+B) 2 33KV UG Cabling Works (C+D) 3 Cable

More information

Addendum 1.0. For Lagrange Library Specification 1.0. Technology Consultants Fort Wayne, Indiana

Addendum 1.0. For Lagrange Library Specification 1.0. Technology Consultants Fort Wayne, Indiana Addendum 1.0 For Lagrange Library Specification 1.0 Technology Consultants Fort Wayne, Indiana TECHNICAL SPECIFICATIONS FOR TELECOMMUNICATION DISTRIBUTION FACILITIES AND INSTALLATION PROCEDURES For Lagrange

More information

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the

More information

BANK OF INDIA, GANDHINAGAR ZONE

BANK OF INDIA, GANDHINAGAR ZONE BANK OF INDIA, GANDHINAGAR ZONE TENDER FOR ELECTRICAL WORK FOR BANK OF INDIA CONFERENCE ROOM AT RO, GANDHINAGAR. ISSUED TO :................ CLIENT : ARCHITECT: CHIEF MANAGER WISTAAR Architects & Int.

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT Zirabo Bazar, Ashulia, Savar, Dhaka, Bangladesh Factory List: 1. Inspected by: Khan & Tapu Report Generated by: Khan Inspected on Feb 6 th 2015 SUMMARY factory building

More information

SECTION WIRES AND CABLES

SECTION WIRES AND CABLES SECTION 16120 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the supply and installation of wires and cables and the associated

More information

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS DESCRIPTION BASIC STRUCTURE Foundation Super Structure Internal Walls External Walls Roof RCC footing Framed Structure 200 & 100 mm Solid Concrete Blocks

More information

GENERAL ELECTRIFICATION WORK

GENERAL ELECTRIFICATION WORK TENDER DOCUMENT FOR ELECTRIFICATION, OF AUDITORIUM AT SPIRITUAL GROWTH CENTER, KATRA. GENERAL ELECTRIFICATION WORK KLM DESIGNS INDIA C-79, BASEMENT MALVIYA NAGAR NEW DELHI -110017 TEL 41831089-99 2 CONTENTS

More information

Specification Lightning Protection Systems

Specification Lightning Protection Systems Specification Lightning Protection Systems General: Summary A) This Section specifies the lightning protection system for the building(s) or structure(s). This system provides safety for the building and

More information

BANK OF INDIA ( ZONAL OFFICE ) COIMBATORE ZONE TENDER INTERIOR FURNISHING, ELECTRICAL & AIRCONDITIONING WORKS FOR BANK OF INDIA, MADAGUPATTI BRANCH.

BANK OF INDIA ( ZONAL OFFICE ) COIMBATORE ZONE TENDER INTERIOR FURNISHING, ELECTRICAL & AIRCONDITIONING WORKS FOR BANK OF INDIA, MADAGUPATTI BRANCH. BANK OF INDIA ( ZONAL OFFICE ) COIMBATORE ZONE TENDER INTERIOR FURNISHING, ELECTRICAL & AIRCONDITIONING WORKS FOR BANK OF INDIA, MADAGUPATTI BRANCH. EMD AMOUNT RS D.D.NO DATED ISSUED BY BANK FAVOURING

More information

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (4th)

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (4th) Factory Name Address Joyna Bazer Road, Jamirdia, Valuka Factory ID 9504 Electrical Safety dates Initial Date 06/07/2014 Date of 5 th Follow Up Report Received Date 07/27/2015 Date of 6 th Follow Up Date

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

(Citizen)/ Evana/Khawaja (777 Energy Cable)/RR/Macro/ Transcom (Transtec)

(Citizen)/ Evana/Khawaja (777 Energy Cable)/RR/Macro/ Transcom (Transtec) Specification of Renovation Works at Khulna Polytechnic Institute, Sylhet Technical School & College and Rangpur Technical School and College Lot - 1 A. RENOVATION WORK FOR WOOD WORKSHOP IN SYLHET TECHNICAL

More information

1. Approved Manufacturers: Carlon Electrical Products, Cantex, or approved equal.

1. Approved Manufacturers: Carlon Electrical Products, Cantex, or approved equal. PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of Texas State University for for Electrical System. B. Texas State University recognizes

More information

ORISSA SMALL INDUSTRIES CORPORATION LTD (A Govt of Orissa undertaking) No. OSIC/CONSTN/ /007 Date:

ORISSA SMALL INDUSTRIES CORPORATION LTD (A Govt of Orissa undertaking) No. OSIC/CONSTN/ /007 Date: Sl. No. ORISSA SMALL INDUSTRIES CORPORATION LTD (A Govt of Orissa undertaking) No. OSIC/CONSTN/2015-16/007 Date: 11.07.16 TENDER CALL NOTICE The Managing Director O S I C ltd, Khapuria, Cuttack invites

More information

Product Application. Prestige Power Post in White Epoxy Coated Aluminium Finish

Product Application. Prestige Power Post in White Epoxy Coated Aluminium Finish Product Application 83 Prestige Power Post in White Epoxy Coated Aluminium Finish 84 Floor Distribution Technical Floor Distribution Technical 85 Range Technical Data Raised Floor Systems Interact Underfloor

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION 1.0 SPECIFICATION OF FLAMEPROOF DISTRIBUTION BOARD, FIXTURES, POWER DISTRIBUTION SYSTEM INCLUDING CABLE LYING & TERMINATION. 1.0.1 Scope The following Specification flameproof Distribution

More information

Bill of Quantity B. CIVIL WORKS Project :

Bill of Quantity B. CIVIL WORKS Project : B. CIVIL WORKS 205 A Cement Board Providing and Fixing 8mm thick for external and internal wall without infill,erected with C channel and required material as directed by A/E(Everest Cement Board,Shera

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:

More information

Nairobi Funeral Home and Forensics BOREHOLE BILLS OF QUANTITIES

Nairobi Funeral Home and Forensics BOREHOLE BILLS OF QUANTITIES Nairobi Funeral Home and Forensics BOREHOLE BILLS OF QUANTITIES 26/10/2015 Item Description Qty Unit Supply, deliver, install, test and commission the following borehole equipment including all materials

More information

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY):

PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY): PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY): 01 Providing and Fixing of CPVC pipes confirming to ASTM standard including all CPVC fittings like tees, elbows, bends, unions, coupling, reducer

More information

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) Construction Criteria The unit costs for the Physical Fitness Center (Exercise Room) space type are based on the construction quality and design features in

More information

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION: SECTION 13 05 41 SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED 1-25-13 PART 1 GENERAL 1.1 DESCRIPTION: A. Provide seismic restraint in accordance with the requirements of this section

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

STAGE EFFECTS LIGHTING SYSTEM

STAGE EFFECTS LIGHTING SYSTEM KLM DESIGNS INDIA. 1 SCHEDULE OF QUANTITIES FOR AUDITORIUM AT MATA VAISHNO DEVI SHRINE TRUST, KATRA, JAMMU STAGE EFFECTS LIGHTING SYSTEM ARCHITECTS: - CONSULTANTS:- Structure & Foundations Pvt Ltd KLM

More information

Basic Requirements for Residential Electrical Installations

Basic Requirements for Residential Electrical Installations Basic Requirements for Residential Electrical Installations Wayne County Building Department 428 West Liberty Street Wooster, Ohio 44691 Phone: 330-287-5525 Fax: 330-287-5649 This brochure is intended

More information

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A SPECIFICATIONS AND SCHEDULE OF QUANTITIES Name of work: Renovation of toilets in main building near molecular biology lab Sl Rate Amount Schedule A 1 Demolishing concrete in cement mortar including disposal

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation.

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation. A B C Details of the installation Owner*/Occupier*/Customer*/ (*Delete as necessary) Only for the reporting on the condition of an existing installation Purpose for which this report is required Installation

More information

RAJVILAS GADKARI Architects and Interior Designers

RAJVILAS GADKARI Architects and Interior Designers Tender For Electrical Works At BANK OF INDIA / RAIGAD ZONAL OFFICE KHARGHAR BRANCH Ashtvinayak Residecy, Plot No. 5 & 6., Shop No. 1 to 4, Gound Floor, Sector- 35D, Kharghar, Navi Mumbai. RAJVILAS GADKARI

More information

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS 1 Introduction 1.1 In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a utility. It should be assumed that all new

More information

A/E Design Deliverable Checklist

A/E Design Deliverable Checklist A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic

More information

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -SQA- SCOTTISH QUALIFICATIONS AUTHORITY Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -Module Number- 4110361 -Session- 1991-92 -Superclass- TH -Title- ELECTRICAL

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Kitchen Remodel Estimator. Contact Info: Project Summary: Design. Demo

Kitchen Remodel Estimator. Contact Info: Project Summary: Design. Demo Kitchen Remodel Estimator Thinking about remodeling your kitchen? If you would like a free bid from Excel Builders, we have provided a list of questions that will need to be filled out with detail in order

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study PART 1: GENERAL 1.01 Underground Ducts and Manholes A. The work included in this section of the construction standards consists of the design requirements for the complete layout and installation of a

More information

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION SECTION 74 AIRPORT OBSTRUCTION LIGHTS (FAA L-119) 74-1 GENERAL The Contractor shall perform all work required by the plans and specifications for construction of obstruction lights in accordance with the

More information

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI The accurate study of the proportions and modularity, led us to design a elementary module from the standard dimensions of around 2,5 x 5,5 x 3 meters. All modules are designed for minimal waste of space

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 48.00 10 (October 2006) ---------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 48.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the

More information

WATER WORKS SECTION भ रत य प र द य स स थ खड़गप र Indian Institute of Technology, Kharagpur TENDER NOTICE

WATER WORKS SECTION भ रत य प र द य स स थ खड़गप र Indian Institute of Technology, Kharagpur TENDER NOTICE WATER WORKS SECTION भ रत य प र द य स स थ खड़गप र Indian Institute of Technology, Kharagpur TENDER NOTICE No. : IIT/WW/2017-18/ 35 Dt. : 19.01.2018 The Sr. Executive Engineer (Water Works), IIT Kharagpur

More information

Section BUILDINGS, SHELTERS, ENCLOSURES

Section BUILDINGS, SHELTERS, ENCLOSURES Section 13121 BUILDINGS, SHELTERS, ENCLOSURES Part 1 GENERAL 1.1 SECTION INCLUDES 1.2 A. Pre-engineered buildings. B. Pre-engineered shelters. C. Pre-engineered enclosures. D. Electrical wiring and devices

More information

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES Guidelines effective March 5, 2007 NES is committed to providing safe, reliable electric service at a reasonable price for all of our customers. These guidelines offer direction for activities relating

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Telecommunication Spaces

Telecommunication Spaces Telecommunication Spaces October 19, 2016 Page 1 Revision History Telecommunication Spaces Standard Effective Date Email Version Contact Phone OIT-TS strevena@csustan.edu 1.0 Stan Trevena 209.667.3137

More information

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions C&G 2382 BS7671:2008 17 th Edition IEE Wiring Regulations 25 Questions 1. BS7671 states that installation design must take into account a. current copper prices b. the effects of climate change c. a comparison

More information

Communications Page 1 of 9

Communications Page 1 of 9 Page 1 of 9 Last Update: April 23 rd, 2014 Introduction Design In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a

More information

INTRODUCTION. We feel pleasure to introduce ourselves as manufacturers and suppliers of multifarious industrial storage systems and cable tray.

INTRODUCTION. We feel pleasure to introduce ourselves as manufacturers and suppliers of multifarious industrial storage systems and cable tray. T M MFG. & TRADING CORPORATION Super Market Display Rack, Wall Mounted Display System, Slotted Angle Steel Rack, Mezzanine Floor, Heavyduty Pallet Rack, library Stack Rack, Mobile Rack/Compactor, Plastic

More information

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005 RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 002 947 R3 Updated April 2005 Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance

More information

Daytona Beach Pier Building Renovation Jun 2010

Daytona Beach Pier Building Renovation Jun 2010 SECTION 15150 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Document No Issue Date: May 15, 2012

Document No Issue Date: May 15, 2012 Professional Engineer Authenticated TELUS Residential Service Conduit Requirements For Stand-Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

SPACE TYPE: OUTSIDE PARKING (STRUCTURE) SPACE TYPE: OUTSIDE PARKING (STRUCTURE) Construction Criteria The unit costs for Outside Parking (Structure) space types are based on the construction quality and design features in the following table.

More information

2015 Code Rollout Meeting Q & A

2015 Code Rollout Meeting Q & A 1 SECTION QUESTION SaskPower Inspections Dept. ANSWER 2 3 4 5 6 7 8 9 10 11 12 15-02-024 15-02-200 15-02-200 15-02-200 15-02-314 Are existing single or double 'weather proof when not in use' covers allowed

More information

GENERAL PLAN REVIEW REQUIREMENTS

GENERAL PLAN REVIEW REQUIREMENTS GENERAL PLAN REVIEW REQUIREMENTS Cover Letter A letter (or an authorized pre-printed form) authorizing CCIS to perform the Plan Review is required. CCIS performs plan reviews for the ICC International

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15420 DRAINAGE AND VENT SYSTEMS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All cleanouts above finished (accessible and non-accessible) ceilings shall be extended to the floor above. B. Do

More information

: Supply, Installation, Testing &Commissioning of 2 Nos. Façade cleaning Roof Top Trolleys at SCOPE Minar, Laxmi Nagar, Delhi

: Supply, Installation, Testing &Commissioning of 2 Nos. Façade cleaning Roof Top Trolleys at SCOPE Minar, Laxmi Nagar, Delhi SCOPE Minar/MMO/17-18/173 15/12/2017 NOTICE INVITING TENDER Subject: Supply, Installation, Testing &Commissioning of 2 Nos. Facade cleaning Roof Top Trolleys at SCOPE Minar, Laxmi Nagar, Delhi-110092.

More information

PASSIVE FIRE PROTECTION PRODUCTS

PASSIVE FIRE PROTECTION PRODUCTS OCTOBER 2016 PASSIVE FIRE PROTECTION PRODUCTS www.allproof.com CONTENTS FIRE TESTING 1 ADVANCED INTUMESCENT 2 ALLPROOF INTUMESCENT TECHNOLOGY: 2 LOW PROFILE S 3 CONCRETE SLAB TEST RESULTS: 4 FLOOR WASTE

More information

Name of Work: Interior and Furnishing Works for Second Floor of Bank of India Headquarters at H-2, Connaught Circus

Name of Work: Interior and Furnishing Works for Second Floor of Bank of India Headquarters at H-2, Connaught Circus Name of Work: Interior and Furnishing Works for Second Floor of Bank of India Headquarters at H-2, Connaught Circus S. No. Description Unit Qty. Rate Amount I. PARTITIONS AND PANELLING:- 1. Full Height

More information

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd RAM ELEVATORS Elevator Electrical Planning Guide This guide is intended for people with an understanding of electricity. If you are not, please consult a licensed electrician as errors in application of

More information

CIS Electrical Services Standard

CIS Electrical Services Standard CIS Electrical Services Standard The University of Sydney Engineering & Sustainability Team Document Control Document Name: CIS Electrical Services Standard Document ID: CIS-PLA-STD-Electrical Services

More information

Typical Finished Basement Details

Typical Finished Basement Details Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details

More information

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially: 04222 CONCRETE UNIT MASONRY (UNREINFORCED ONLY) SPECIFIER: Use this section only for UNREINFORCED concrete masonry. Its only reinforcement is in the horizontal joints. It covers ONLY plain blockwork (no

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

Bed Docker. Installation Manual. Model BD 600/601

Bed Docker. Installation Manual. Model BD 600/601 Bed Docker Installation Manual Bed Docker Model BD 600/601 Overview The Modular Services Bed Docker provides a docking location for the patient bed with connections for electrical devices on each side.

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT ADVANCE WORLD LIMITED Lalkha Shair Char, Fatullah, Narayanganj, Dhaka, Bangladesh Factory List: 1.. Inspected by: Sherub Tenzin & Md. Moin Hasan Report Generated by:

More information