1 Name of Work: Interior and Furnishing Works for Second Floor of Bank of India Headquarters at H-2, Connaught Circus S. No. Description Unit Qty. Rate Amount I. PARTITIONS AND PANELLING:- 1. Full Height Partition: Providing and fixing in position Full Height partition including 30 mm thick flush door in framework of 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm kail wood section with 6 mm thick plywood on both sides finished with 0.8 mm thick laminate of approved make including grooves as/ Architect. Item to include 65 X 65 mm factory made laminated veneer lumber door frame and additional framework and laminated veneer lumber beading required for providing glazing. All exposed surfaces, grooves and the like to be finished in melamine polish of matching laminate colour including all necessary fittings and SS hardware of make hettich/ hafele/ ebco. The rate to include provision of extra frame work as necessary for skirting and making cutouts for electrical switches, switch boxes, conduiting, door/ glazing as per drawings. The wood frame work to be applied with 2 coats of fire retardent paint and 1 coat of anti-termite wood preservative all complete as per direction of Engineer-in-charge/ Architect and drawings. Sq. ft Note:- a) In case of false ceiling, the vertical kail wood members to be fixed to RCC ceiling but the area of partition payable will be below the false ceiling only. b) Measurement of height shall be taken from finished floor only, in case of varying heights on either side of partition, average height shall be considered. c) Openings/ glass shall not be measured for payment. d) Contractor to use proper masking tapes while polishing grooves etc. to prevent any damage to laminate. Geotech technical Associates (P) Ltd. 1

2 2. Low Height Partition: Providing and fixing in position solid Low Height partition upto height of 1200 mm including 30 mm thick flush door in framework including door in 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm kail wood section with 6 mm thick plywood on both sides finished with 0.8 mm thick laminate/ fabric covered soft board of approved make/ colour including grooves as/ Architect. Item to include 65 X 65 mm factory made laminated veneer lumber member for door frame and top beading for partition of 15 X 75 mm. All exposed grooves and the like to be finished in melamine polish of matching laminate colour or as directed including all necessary fittings and SS hardware of make hettich/ haffele/ ebco. The rate to include provision of extra frame work as necessary for skirting and making cut-outs for electrical switches, switch boxes, conduiting as per drawings. Sq. ft The wood frame work to be applied with 2 coats of fire retardent paint and 1 coat of anti-termite wood preservative all complete as per the drawings and directions of Engineer-in-charge/ Architect and drawings. Note:- a) Measurement of height shall be taken from finished floor only, in case of varying heights on either side of partition, average height shall be considered. b) Openings/ glass shall not be measured for payment. c) Contractor to use proper masking tapes while polishing grooves etc. to prevent any damage to laminate. 3. Wall Panelling: Providing and fixing in position wall panelling over existing framework with 6 mm thick plywood on one side finished with 0.8 mm thick laminate of approved make including grooves as/ Architect and top to be finished with laminated veneer lumber 15 mm thing with rounded edge. The rate to include for provision of extra frame work as necessary for skirting and making cut-outs for electrical switches, switch boxes, conduiting, receiving A.C.'s etc. as per drawings. All exposed surfaces, grooves and the like to be finished in melamine polish of matching laminate colour or as directed. The wood frame work to be applied with 2 coats of fire retardent paint and 1 coat of anti-termite wood preservative all complete as per the drawings and directions of Engineer-in-charge/ Architect and drawings. Contractor to use proper masking tapes while polishing grooves etc. to prevent any damage to laminate. [Note:- Incase of wall not being true to plumb extra shims of kail wood shall be provided. [Nothing extra shall be payable in this regard.] Sq. ft Geotech technical Associates (P) Ltd. 2

3 4. Providing and fixing glazed door and fixed glazing (full height glass partition) with 12 mm thick toughened glass of approved make with all SS patch fittings (Hettich/ Haffele/ Dorma) and frosting as per drawing. Item to include floor springs, lock, 300 mm long D- handles and other necessary hardware of Stainless Steel of make Hettich/ Haffele/ Dorma all complete as per the directions of Architect/ Engineer-in-charge. a Fixed Glazing Sq. ft b Openable door Sq. ft Providing and fixing 12 mm thick toughened glass in full/ low height partitions of approved make with frosting, edge polishing etc. all complete. Item to include all necessary hardware of SS finish as approved by the Project Consultant/ Bank required for fixing the glass all complete as per the directions of the Architect. Total of S.H. (I) of Partitions and Panelling Sq. ft II. STORAGE:- 6. Providing and fixing full height storage (upto 2600 mm high) and 450 mm deep and made from 18 mm thick pre-laminated particleboard, except back, which is made from 9 mm thick pre-laminated particleboard. The storage unit to have pre-laminated partition to make pigeon hole storage. The unit shall be provided with plastic headed leveling bolts of M6 size to take care of any variations in the floor level. Sq. ft Providing and fixing full height storage (upto 900 mm high) and 450 mm deep and made from 18 mm thick pre-laminated particleboard, except back, which is made from 9 mm thick pre-laminated particleboard. The units to have hinged door shutters having spring-loaded auto-closing hinges. All units to have a multi purpose type lock and to be provided with Stainless steel handles of matt finish. All units shall be provided with plastic headed leveling bolts of M6 size to take care of any variations in the floor level. Sq. ft Geotech technical Associates (P) Ltd. 3

4 8. Providing and fixing Single Drawer 380 mm wide having outer casing (except back) and drawer front made from 18 mm thick prelaminated board. The casing back is made from 9 mm thick prelaminated board. The box drawers to have an external fascia height of approx. 150 mm. The drawer movement shall be on full-panel type drawer runners having rollers which also form the sides of the drawer tray. These runners shall be of the single extension type for the box drawers. The height of these panel slides/ sides for box drawers is 86 mm. The drawer shall be provided with a multi-purpose locking system and stainless steel handles in the matt finish for all drawer fascia. Nos Total of S.H. (II) of Storage III. CEILING AND FINISHING WORKS:- 9. Repairing and making of addition and alteration to false ceiling including making coves and providing and fixing of framework made of special sections power pressed as per requirement from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats. The item to include jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher suitable for board as per manufactures specification and also including the cost of making openings for light fittings, shifting of light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge with: 12.5 mm thick tapered edge gypsum board conforming to IS:2095- Part-I of India Gypsum/ approved make for both framework and the board. Sq. ft Item to include painting with and one coat of primer and plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work with rollers/ spray of make Asian/ Berger/ Dulux paint for the entire ceiling area. Note:- Measurement shall be taken of the plan area only. Suspending system and frame work shall match layout of Electrical/ fire protection wiring/ fixtures etc. Rate to include provision of extra frame work needed due to above and to include necessary scaffolding etc. all complete. Geotech technical Associates (P) Ltd. 4

5 10. Providing and fixing false ceiling base with 12 mm thick commercial ply over wooden framework of 50 X 50 mm section all complete as per the directions of Engineer-incharge/ Architect/ drawings. The ceiling basework to be finished as follows: a Using 1 mm laminate of approved make over base as above and including making grooves and finishing the grooves in melamine polish etc. [Note:- Contractor to use proper masking tapes while polishing grooves etc. to prevent any damage to laminate.] Sq. ft Providing and applying POP punning of mm thickness over plastered surface to prepare the surface even and smooth all complete as per the directions of Engineer-in-charge. 12. Providing and applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer. Sq. ft Sq. ft Finishing walls with textured interior paint of required shade: New work (Two or more coats 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint 2.20 kg/10 sqm with rollers/ spray of make ACRO/ approved make (Basic cost of paint: 60 Rs/ Sq. ft. excluding all VAT, taxes, carriage etc.) Sq. ft Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work with rollers/ spray of make Asian/ Berger/ Dulux paint. 15. Providing and fixing polished Travertino Gold stone wall cladding with cement mortar/ adhesive of approved brand and manufacture all complete as per the directions of Architect/ Engineer-in-charge. Total of S.H. (IV) of Ceiling and Finishing Sq. ft Sq. ft IV. TABLES:- Geotech technical Associates (P) Ltd. 5

6 16. Providing and fixing in position Staff Table of size 3'-6" X 2'-2" by using 0.8 mm thick laminate and 25 mm thick particle board for top with postforming and 18 mm thick particle board for all other horizontal and vertical members. Telescopic CPU Stand/ ready made Keyboard tray shall be provided. All exposed particle board surfaces to be finished with 0.8 mm thk. laminate of approved make & shade and all exposed edges of table top & particle board to be finished in PVC edge banding. The item to include all necessary hardware and fittings in Stainless Steel finish and wire manager complete in all respects. 17. Providing and fixing in position Manager Table of size 5'- 0" X 2'-6" by using 0.8 mm thick laminate and 25 mm thick particle board for top with postforming edges and 18 mm thick particle board for all other horizontal and vertical members and modesty panel. Telescopic CPU Stand/ ready made Keyboard tray shall be provided. All exposed particle board surfaces to be finished with 0.8 mm thk. laminate of approved make & shade and all exposed edges of table top & particle board to be finished in PVC edge banding. The item to include all necessary hardware and fittings in SS finish and wire manager with 8 mm thick toughened glass top with bevelled edges and edge polishing complete in all respects. 18. Providing and fixing in position Regional Manager Table of size 6'-0" X 2'-6" by using 0.8 mm thick laminate and 25 mm thick particle board for top with postforming edges and 18 mm thick particle board for all other horizontal and vertical members and modesty panel. Telescopic CPU Stand/ ready made Keyboard tray shall be provided. All exposed particle board surfaces to be finished with 0.8 mm thk. laminate of approved make & shade and all exposed edges of table top & particle board to be finished in PVC edge banding. The item to include all necessary hardware and fittings in SS finish and wire manager with 8 mm thick toughened glass top with bevelled edges and edge polishing complete in all respects. Nos Nos Nos Geotech technical Associates (P) Ltd. 6

7 19. Providing and fixing in position Runner Table for dispatch of 2'-0" wide by using 0.8 mm thick laminate and 25 mm thick particle board for top with postforming and 18 mm thick particle board for all other horizontal and vertical members. Telescopic CPU Stand/ ready made Keyboard tray shall be provided. All exposed particle board surfaces to be finished with 0.8 mm thk. laminate of approved make & shade and all exposed edges of table top & particle board to be finished in PVC edge banding. The item to include all necessary hardware and fittings in Stainless Steel finish and wire manager complete in all respects. Ft Providing and placing Waiting table for customer lounge of size 4'-0" X 2'-0" made of 19 mm thick blockboard and finished with 1 mm thick laminate on all exposed surfaces all complete as per drawings. The table shall have 10 mm thick toughened glass top with SS spacers lazer jointed and maximum height of table to be 350 mm. Total of S.H. (V) of Counters and Tables Nos V. MISCELLANEOUS:- 21. Providing and fixing laquered glass on existing basework with adhesive etc. as required all complete as per the directions of Architect/ Engineer-in-charge. Sq. ft Providing and fixing MDF Dual Grill Board of make Glo/ approved make and finishing the board with metallic Gold/ Bronze/ Silver duco paint all complete as per the directions of Architect/ Engineer-in-charge. 23. Supplying and fixing of Artwork of make Euro/ Glo (Base cost- 4000/- excluding Vat, octroi, cartage and all other taxes etc. which shall be borne by the contractor) all complete as per the directions of Architect/ Engineerin-charge. Sq. ft Nos Dismantling of partitions, panelling, storages, tables, plaster, etc. including stacking servicable materials properly with all leads and lifts etc., complete and carting away non-servicable material as directed. Total of S.H. (VI) of Miscellaneous Nos VI. SALVAGE:- Contractor to quote individual rates not below reserve price (RP). Material of Salvage should be disposed off on as-is where is basis. Geotech technical Associates (P) Ltd. 7

8 1. Disposal of salvage tables (all sizes and shapes) as per the reserved cost including removal all complete as per the directions of Engineer-in-charge (RP Rs. 1500/- per Table, Drawer Units are not included). 2. Disposal of salvage full height aluminium partitions as per the reserved cost including removal etc. all complete as per the directions of Engineer-in-charge (RP Rs. 40/- per Sq.ft). 3. Disposal of salvage full height wooden partitions as per the reserved cost including removal etc. all complete as per the directions of Engineer-in-charge (RP Rs. 30/- per Sq.ft). 4. Disposal of salvage low height aluminium partitions as per the reserved cost including removal etc. all complete as per the directions of Engineer-in-charge (RP Rs. 30/- per Sq.ft). 5. Disposal of salvage low height wooden partitions as per the reserved cost including removal etc. all complete as per the directions of Engineer-in-charge (RP Rs. 30/- per Sq.ft). 6. Disposal of salvage low height storage as per the reserved cost including removal etc. all complete as per the directions of Engineer-in-charge. Facia shall be measured for payment (RP Rs. 75/- per Sq.ft). Total of S.H. (VII) of Salvage Nos Sq.ft Sq.ft Sq.ft Sq.ft Sq.ft VIII. ELECTRICAL WORKS:- 25. Supplying, installation, testing and commissioning of following light fixtures with electronic Ballasts, electronic transformer, Tubes, lamps, all fixing materials including connecting wires etc. all complete as per the directions of Engineer-in-charge. i) 4 X 14 W TL5 TBS 669 luminaire of make Philips. Nos ii) BBS170 X 1 X DLED 5000PSU WH complete as required make Philips 15 W (noiminal)/ BZSLO 15 W Bajaj/ WIPRO Maxi IRIS LED. Total of S.H. (VIII) of Electrical Works Nos Geotech technical Associates (P) Ltd. 8

Tender Schedule for INTERIOR Works at ARUMBAKA Branch (CODE NO 6517) Particulars Quantity Unit Rate Amount

Tender Schedule for INTERIOR Works at ARUMBAKA Branch (CODE NO 6517) Particulars Quantity Unit Rate Amount Sl. No. Tender Schedule for INTERIOR Works at ARUMBAKA Branch (CODE NO 6517) Particulars Quantity Unit Rate Amount 1 Item. / Particulars Full height partitions: Providing and fixing partitions with following

More information

Quotations invited for Interior work of Conference Rooms at YWCA of Delhi

Quotations invited for Interior work of Conference Rooms at YWCA of Delhi Quotations invited for Interior work of Conference Rooms at YWCA of Delhi Sealed competitive quotations are invited from reputed interior decorators/contractors, having proven track record in the field,

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

BOQ for Lintel, Chajja, Brick work & Plastering work at Pkg. - III - Phase - I

BOQ for Lintel, Chajja, Brick work & Plastering work at Pkg. - III - Phase - I BOQ for Lintel, Chajja, Brick work & Plastering work at Pkg. - III - Phase - I S.No. Description Unit Qty RATE Amount PART-I CIVIL WORKS B-PLAIN AND REINFORCED CEMENT CONCRETE : Notes : ( the following

More information

LINEA PLANA PRODUCT SHEET. This product sheet complies with the provisions of Italian Law Decree no. 206/2005 the "Consumer Code"

LINEA PLANA PRODUCT SHEET. This product sheet complies with the provisions of Italian Law Decree no. 206/2005 the Consumer Code LINEA PLANA PRODUCT SHEET This product sheet complies with the provisions of Italian Law Decree no. 206/2005 the "Consumer Code" Pagina 1 KITCHEN LINEA GROOVE SYSTEMS: "PIATTA" aluminium spacer in a stainless,

More information

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work

SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work Creation of Three clean area rooms (Master Mix, Amplification and Hybridization rooms) for Line Probe Assay with two

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount

No # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount Revised Schedule B as per corrigendum no. SASB/NIT/Works/818/2016/09 dated 28.01.2016. SCHEDULE B (FINANCIAL BID) B- a FABRICATION AND SUPPLY OF 200 EUROPEAN TYPE TOILETS (Rate to be quoted in Rupees both

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

Bill of Quantity B. CIVIL WORKS Project :

Bill of Quantity B. CIVIL WORKS Project : B. CIVIL WORKS 205 A Cement Board Providing and Fixing 8mm thick for external and internal wall without infill,erected with C channel and required material as directed by A/E(Everest Cement Board,Shera

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

V1703 SYSTEM DESCRIP TION JB 2000 AT HOME WITH ANY STYLE

V1703 SYSTEM DESCRIP TION JB 2000 AT HOME WITH ANY STYLE V1703 SYSTEM DESCRIP TION JB 2000 AT HOME WITH ANY STYLE TURE FINISHING PARTITIONS CEILINGS DOORS FURNITURE FINISHING PARTITIONS CEILINGS DOO JB 2000 The JB 2000 relocatable partition wall is a modular,

More information

UNION BANK OF INDIA TENDER DOCUMENTS

UNION BANK OF INDIA TENDER DOCUMENTS UNION BANK OF INDIA ATM for Union Bank of India, Chethupet, Thiruvannamalai District. TENDER DOCUMENTS for Furnishing & Electrical Works. ARCHITECTS: M/S. KARTHIGEETA & ASSOCIATES ARCHITECTS, INTERIOR

More information

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc. P a g e 1 PART I. GENERAL 1.01 Scope A. Furnish and install SoftWalls HIGH-TENSION Acoustical & Tackable Stretch Fabric Systems B. Related Work Specified Elsewhere: 1.Preparation of a smooth, flat and

More information

Division 09 FINISHES TABLE OF CONTENTS

Division 09 FINISHES TABLE OF CONTENTS Division 09 FINISHES TABLE OF CONTENTS 09 1000 GENERAL... 3 A. RELATED SECTIONS... 3 B. MAINTENANCE OF FINISHES... 3 C. PUBLIC AREAS... 3 D. CUTTING AND PATCHING... 3 E. CLEANING... 3 F. RECOMMENDED FLOORING

More information

University Apartments on Brooklyn PROJECT MANUAL

University Apartments on Brooklyn PROJECT MANUAL Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section

More information

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES PART 1 - GENERAL SECTION 122413 - ROLLER WINDOW SHADES 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations DIVISION 11 - EQUIPMENT 11400 FOOD SERVICE EQUIPMENT A. Design Considerations 1. The A/E shall use the services of a food service equipment specialist in preparation of kitchen areas and other food preparation

More information

Sound Absorbing Acoustic Materials

Sound Absorbing Acoustic Materials Sound Absorbing Acoustic Materials 1. Grooved Wood (or Melamine) Perforated Acoustic Panel. Specification: TT 3/9 8 18 Groove distance 3mm/rear hole distance 9mm, centre to centre distance 8mm, thickness

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

PART A: JOB PROCDRE FOR PLASTERING

PART A: JOB PROCDRE FOR PLASTERING PART A: JOB PROCDRE FOR PLASTERING 1. SCOPE: The scope of this procedure shall apply to all cement plaster finishes to column, ceilings, walls and similar surfaces on backgrounds met with such as brick,

More information

Drywall and Plastering

Drywall and Plastering Drywall and Plastering Drywall Drywall 120433 1 / 2 4 X 8 White Drywall Approx. 60/Lift None 120442 5 / 8 4 X 8 Firecode White Drywall Approx. 48/Lift None 120451 1 / 2 4 X 8 XP Drywall Approx. 48/Lift

More information

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum

More information

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 08211 VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division I Specification

More information

Dena Bank, Churu DENA BANK. DENA bank Zonal Office, 5 th Floor, B-12, Business Avenue, Adarsh Nagar. Jaipur TENDER DOCUMENT. For FURNISHING WORKS

Dena Bank, Churu DENA BANK. DENA bank Zonal Office, 5 th Floor, B-12, Business Avenue, Adarsh Nagar. Jaipur TENDER DOCUMENT. For FURNISHING WORKS DENA BANK DENA bank Zonal Office, 5 th Floor, B-12, Business Avenue, Adarsh Nagar Jaipur TENDER DOCUMENT For FURNISHING WORKS At CHURU BRANCH, RAJASTHAN. ARCHITECTS AR. REKHA NEMANI C-40, DEV NAGAR, TONK

More information

Estimate FOR THE SEPTIC TANK

Estimate FOR THE SEPTIC TANK Estimate FOR THE SEPTIC TANK S.NO ITEM DESCRIPTION. 1 Excavation in soil,soft & hard murum... Qty UNIT Rate Excavation for footing, machine foundation, plinth beams, wall footing, gutters,brick wall, tanks

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof

WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS DESCRIPTION BASIC STRUCTURE Foundation Super Structure Internal Walls External Walls Roof RCC footing Framed Structure 200 & 100 mm Solid Concrete Blocks

More information

SECTION CERAMIC TILE

SECTION CERAMIC TILE SECTION 09300 CERAMIC TILE PART 1 GENERAL 1.1 SCOPE A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions, Division 00 & 01 Specification Sections,

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'

More information

Introduction. Disclaimer. Table of contents

Introduction. Disclaimer. Table of contents Updated July 18, 2012 Introduction The Cambridge Elevating Limited-Use / Limited-Application Elevator is designed to service schools, libraries, low rise, low occupancy commercial buildings, churches and

More information

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers) SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with

More information

SCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD AND

SCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD AND SCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD Zotos Place, 37 Old Kilcullen Road, Bryanston P O Box 68012, Bryanston, 2021 Tel: 011 463 2124 Fax: 011 463 2129 AND ERF: TOWNSHIP:

More information

Modularity. Flexibility is maximized with basic modular components that combine to create many configurations.

Modularity. Flexibility is maximized with basic modular components that combine to create many configurations. Product Specification Document Date Published: September 17, 2004 AXIOM CONSOLE ABOUT AXIOM CONSOLE The ultimate in affordable modularity, the Axiom console family with its space age, structural polymer

More information

Features and benefits. Precision made using cnc machinery to ensure accurate and unobtrusive installation.

Features and benefits. Precision made using cnc machinery to ensure accurate and unobtrusive installation. Waldor 50, Tile-a-Door+, Maghatch, Combihatch Access covers for use in ceilings and tiled wall surfaces Steel access panels for accessing services within walls and ceilings. The Maghatch and Combihatch

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 10'2 [3.1] Maximum Opening Width: Unlimited Select for Special Needs: Use

More information

RCC PRECAST TOILET UNITS

RCC PRECAST TOILET UNITS RCC PRECAST TOILET UNITS TOILET UNIT PHOTO TOILET UNIT PLANS PDG Vinay Kulkarni Wins Coordinator West Zone Quotation for Toilet Units with Bio Digester Sr. Description Price (Rs.) Unit No. 1 TTSS1: 1 Super

More information

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS Page 1 of 6 SECTION 08 32 20 HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED BI-FOLD GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum

More information

2000 POCKET DOOR TECHNICAL DATA

2000 POCKET DOOR TECHNICAL DATA 2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

1.3 Work shall include all reinforcement and accessories necessary to complete installation. CERAMIC TILING GENERAL INFORMATION 1.1 Ceramic mosaic tile floors and bases, glazed wall tile wainscots and walls, and marble thresholds. 1.2 Installation will typically be with latex-portland cement mortar

More information

MS 360 SLIDING MALL FRONT INSTALLATION INSTRUCTION MANUAL

MS 360 SLIDING MALL FRONT INSTALLATION INSTRUCTION MANUAL MS 360 SLIDING MALL FRONT INSTALLATION INSTRUCTION MANUAL January 2000 CONTENTS General Information........................................... Page 2 Assembly Drawing............................................

More information

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES SECTION 10712 COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Functional exterior shutters. B. Exterior shutter hardware. 1.2 RELATED SECTIONS A. Section 09900 - Paints

More information

A. Section includes interior woodwork for the following applications:

A. Section includes interior woodwork for the following applications: SECTION 06 40 23 INTERIOR ARCHITECTURAL WOODWORK PART 1 - GENERAL 1.1 SUMMARY A. Section includes interior woodwork for the following applications: 1. Wood cabinets. 2. Plastic-laminate cabinets. 3. Solid-surfacing-material

More information

BOQ. Annexure-I. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No.

BOQ. Annexure-I. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No. Name of work: Renovation work for Pantry in hostel Kameng, Umium, Barak & Dibang at IITG campus Item No. Description of item Unit Quantity Rate (Rs.) Rate in words Amount(Rs.) Part-A: Civil works 1 Demolishing

More information

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS ARCHITECTURAL FABRICATIONS PRODUCT BROCHURE Feature Beam Anodised Products Rainscreen Panels Fascia Panels & Soffits Ultima Insulated Panels Perforated Panels Cills, Fins & General Pressings Column Covers

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 12 2113 - LOUVER BLINDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

COUNTERTOPS/ACCESSORIES

COUNTERTOPS/ACCESSORIES COUNTERS/ACCESSORIES Laboratory Cabinetry and Specialties Table of Contents COUNTERS Terms and Codes... 2 Laminate Series... 3-4 LS05: 3mm edge top, applied 3mm edge backsplash and endsplash... 3 LS25:

More information

MODULAR BUILDING SPECIFICATIONS

MODULAR BUILDING SPECIFICATIONS Use Group A - Assembly B Business E Education I - Institutional Construction Type Type II Non Combustible Type V - Wood Floor 12 Outrigger Frame with Cross members Frame: 12 Perimeter Steel Main Beams

More information

Division 11 - Equipment Section 11401

Division 11 - Equipment Section 11401 PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included

More information

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours Basic Edition Standard Estimate Report Page 1 Name 1000 General Conditions 1107 Professional Consultant 10 Surveying 1.00 day 600.000 /day 600 - - - - - - 600 Professional Consultant 600 600 8.00 hours

More information

1.3 REFERENCE STANDARDS

1.3 REFERENCE STANDARDS C/S Acrovyn Doors Section 08210 (08 14 23) Impact Resistant Wood Doors (Barrier Resistant) PART 1 GENERAL 1.1 SCOPE A. All labor, material, equipment, and related services necessary to furnish and install

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

Series - 1

Series - 1 SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

ILKAclean Clean Room Systems

ILKAclean Clean Room Systems ILKAclean Clean Room Systems Systems for Ideas Cleanliness with System ILKAZELL Isoliertechnik GmbH Zwickau is your versatile expert when clean rooms are to meet unique demands. Thanks to the untiring

More information

Our Service. Our Mission

Our Service. Our Mission H e a v y G l a s s S t i k S t a l l P i v o t & H i n g e S l i d e r s A L U M A X S H O W E R Our Product Alumax is the brand most chosen by the professional installer. Ease of installation, safety,

More information

Fully framed glass panels

Fully framed glass panels Fully framed glass panels design elements G1 Fully framed glass panels G1 design The G1 is a fully framed balustrade solution suiting a refined and deliberate architectural style. Rather than minimising

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

BILL NO 1 MASONRY SUPPLEMENTARY PREAMBLES BRICKWORK. Rectification Project Illinge, Eastern Cape Roof Replacement (Partially Done)

BILL NO 1 MASONRY SUPPLEMENTARY PREAMBLES BRICKWORK. Rectification Project Illinge, Eastern Cape Roof Replacement (Partially Done) ectification Project oof eplacement (Partially Done) Item Quantity ate Amount BILL NO 1 MASONY SUPPLEMENTAY PEAMBLES BICKWOK Sizes in descriptions Where sizes in descriptions are given in brick units,

More information

UNION BANK OF INDIA STAFF COLLEGE

UNION BANK OF INDIA STAFF COLLEGE UNION BANK OF INDIA STAFF COLLEGE Proposed Furniture Works in Class Rooms at Union Bank of India Staff College, Kalkere Post, Bannerghatta Road, BENGALURU 560 083. TENDER FOR FURNITURE WORKS TECHNICAL

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

movable walls Space Optimal Solutions

movable walls Space Optimal Solutions Space Optimal Solutions www.movablewall.co.uk by dividing, we multiply Prestige-Space for every occasion From a large meeting room you then have several smaller ones at your disposal Your hotel instantly

More information

CATAMARAN TOWER - 1 Seef Area Plot 19, 20

CATAMARAN TOWER - 1 Seef Area Plot 19, 20 STATUS REPORT NO 18 [As on September 30, 2017] This report is intended as a status report and covers only the activities completed till date, non-completed works and work-in-progress. A. Project Details

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

Technical specifications Prefab Steel Canopy

Technical specifications Prefab Steel Canopy Canopy Structure: Technical specifications Prefab Steel Canopy Design fabrication and installation of pre-engineered / pre- fabricated steel canopy as per the following specification: The canopy steel

More information

YES SSG TU Vent Window System

YES SSG TU Vent Window System YES SSG TU VENT SYSTEM DESCRIPTION 3-1/2" Overall Depth Flat and Pocket Frame Options Variations: Casement Outswing Projected Outswing 1" Glazing Optional Screens YES SSG TU VENT PERFORMANCE FEATURES AAMA/WDMA/CSA

More information

Lift & Slide door installation instructions

Lift & Slide door installation instructions Lift & Slide door installation instructions Installer and Builder Information * Always provide a copy of these instructions for the current or future building owner. WARNING: * If your abilities do not

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members. SECTION 10155 TOILET COMPARTMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Plastic laminate partitions. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Concealed steel support members. B. Section

More information

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often

More information

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A

Name of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A SPECIFICATIONS AND SCHEDULE OF QUANTITIES Name of work: Renovation of toilets in main building near molecular biology lab Sl Rate Amount Schedule A 1 Demolishing concrete in cement mortar including disposal

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

INTERIOR WORK FOR PROPOSED NEW HR DIVISION AT GROUND FLOOR, CORPORATE OFFICE, JANGPURA, NEW DELHI NAME OF WORK:

INTERIOR WORK FOR PROPOSED NEW HR DIVISION AT GROUND FLOOR, CORPORATE OFFICE, JANGPURA, NEW DELHI NAME OF WORK: NAME OF WORK: INTERIOR WORK FOR PROPOSED NEW HR DIVISION AT GROUND FLOOR, CORPORATE OFFICE, JANGPURA, NEW DELHI- 110014. NIT NO. : HPL//CM/12-13/39 dt 22.08.12 ISSUED TO : HINDUSTAN PREFAB LIMITED (A GOVT.

More information

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL 13686.00 GYPSUM BOARD 092116-1 1.1 RELATED DOCUMENTS: SECTION 092116 - GYPSUM BOARD PART 1 - GENERAL A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division

More information

TENDER OF FURNITURE & CIVIL WORK FOR UNION BANK OF INDIA RANIKPUR BRANCH DIST-RAJKOT, GUJARAT

TENDER OF FURNITURE & CIVIL WORK FOR UNION BANK OF INDIA RANIKPUR BRANCH DIST-RAJKOT, GUJARAT ONLY FOR UBI BANK S EMPANELLED CONTRACTORS AHMEDABAD ZONE TENDER OF FURNITURE & CIVIL WORK FOR UNION BANK OF INDIA RANIKPUR BRANCH DIST-RAJKOT, GUJARAT ARCHITECTS: - GIRISH MARU, NIRMAN ARCHITECT, 1, JAGNATH

More information

B. Provide fire-rated access doors where indicated or scheduled.

B. Provide fire-rated access doors where indicated or scheduled. SECTION 08305 ACCESS DOORS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Concepts. Products. Service. Partitions Lindner Logic

Concepts. Products. Service. Partitions Lindner Logic Concepts Products Service Partitions Lindner Logic Building new solutions. Lindner undertakes major projects worldwide in all areas of interior fit-out, insulation technology, industrial services and building

More information

Contract Rates & Specifications for your Home Construction - From the Makers of India s Finest Designer Homes

Contract Rates & Specifications for your Home Construction - From the Makers of India s Finest Designer Homes Quality isn't something that can be argued into a document or promised into it It must be put there on the structure If it isn't put there, even the finest sales talk in the world won't act as a substitute,

More information

Planning and installation instructions

Planning and installation instructions Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...

More information

TENDER FOR INTERIOR WORK OF BRANCH FOR CANARA BANK AT BHAWANIPATANA.

TENDER FOR INTERIOR WORK OF BRANCH FOR CANARA BANK AT BHAWANIPATANA. TENDER FOR INTERIOR WORK OF BRANCH FOR CANARA BANK AT BHAWANIPATANA. CONSULTANT TECHNO ARCH Plot No. N4/236,I.R.C Village,Bhubaneswar.15 Ph.0674-2551479, Mobile. 9437189632 CANARA BANK INTERIOR FURNISHING

More information

EDGEWATER, FLORIDA JUNE 14, 2010

EDGEWATER, FLORIDA JUNE 14, 2010 SECTION 12 2413 - ROLLER WINDOW SHADES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

STATE BANK OF INDIA REGIONAL BUSINESS OFFICE: IV Regional Business Office:Kolkata, Camping at Third Floor, 1/16 VIP Road, Bidhannagar, Kolkata

STATE BANK OF INDIA REGIONAL BUSINESS OFFICE: IV Regional Business Office:Kolkata, Camping at Third Floor, 1/16 VIP Road, Bidhannagar, Kolkata STATE BANK OF INDIA REGIONAL BUSINESS OFFICE: IV Regional Business Office:Kolkata, Camping at Third Floor, 1/16 VIP Road, Bidhannagar, Kolkata-700 054 ALL SBI EMPANELLED CONTRACTORS UNDER CATEGORY 2a,

More information

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced. TOILET COMPARTMENTS GENERAL INFORMATION 1.1 Unless otherwise directed by CU Facilities toilet compartments shall be floor-supported, and urinal screens shall be wall hung, with anchoring devices and accessories

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

Verve Inclusions. 3 Corporate Avenue Rowville VIC T 1800 SIENNA E

Verve Inclusions. 3 Corporate Avenue Rowville VIC T 1800 SIENNA E Verve 3 Corporate Avenue Rowville VIC T 1800 SIENNA E info@siennagroup.com.au Kitchen B F K C I E D J A G Kitchen A: Laminated finish to kitchen benchtops with 32mm thick square edge, selected from the

More information

60 years. of progressive development

60 years. of progressive development Dencroft has been providing a wide range of sectional buildings for over 60 years, making us one of the most experienced designers and manufacturers of quality garages in the UK. Innovation has played

More information

1-3/4 Whisper Core Door Systems

1-3/4 Whisper Core Door Systems 1-3/4 TESTED AND IN COMPLIANCE WITH ASTM E90, ASTM E413, ASTM E1332, & ASTM E2235. DOOR SYSTEMS ARE IN COMPLIANCE WITH HMMA 865-03 & SDI-128 SPECIFICATIONS. COMPLETE WITH PERIMETER SOUND SEALS, BOTTOM

More information

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,

More information

Stiles doors save lives. Stiles is a national leader in fire ratings and maintains a vast portfolio of options to the architect and builder.

Stiles doors save lives. Stiles is a national leader in fire ratings and maintains a vast portfolio of options to the architect and builder. Fire Rated Products Section Contents Fire Rating Charts for Doors FR-1.0-1.1 Fire Rating Chart for Frames FR-1.2-1.3 Glazing Criteria - Doors Glazing Criteria - Windows StileLite Transparent Wall System

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells Shaftwall & Stairwell Systems Fire protection & sound isolation f shafts & stairwells what the job demands Shaftwall & Stairwell Systems Fire protection & sound isolation systems f elevat shafts, stairwells

More information

WoodTrends Acoustical Wood Ceiling System BASIC Specification

WoodTrends Acoustical Wood Ceiling System BASIC Specification WoodTrends Acoustical Wood Ceiling System BASIC Specification SECTION 09570 WOOD CEILING / WALLS PART 1 GENERAL 1.00 GENERAL 1.01 SCOPE A. WoodTrends Acoustical Wood Systems covered by this specification

More information

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Impulse Dual Sit/Stand Consoles. See Appendix A - D for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

Sree Vaishno Enclave-Kompally

Sree Vaishno Enclave-Kompally Sree Vaishno Enclave-Kompally ADDRESS Kompally, Hyderaba Sree Vaishno Enclave -Project Overview Authority Approvals: Gram Panchayat The latest venture ""Sree Vaishno Enclave"" is 44 Independent Duplex

More information

folding wall, fixed panels and Architect: David Easton

folding wall, fixed panels and Architect: David Easton PK-30 System is a meticulously designed and engineered aluminum demountable wall system providing a flexible, environmentally friendly and cost effective way to divide interior space. The System can be

More information