Decorative Division. GANA Decorative Glass LEED White Paper Page 1 of 23

Size: px
Start display at page:

Download "Decorative Division. GANA Decorative Glass LEED White Paper Page 1 of 23"

Transcription

1 Decorative Division White Paper on the Relevance of Decorative Glass Products to the U. S. Green Building Council Leadership in Energy and Environmental Design Green Building Rating System LEED NC Version 3 (with variations for USGBC LEED CI, CaGBC LEED NC & CaGBC LEED CI) The intent of this White Paper is to address areas of the U.S. Green Building Council s Leadership in Energy & Environmental Design (LEED ) Rating System that are relevant to the use of Decorative Glass. This document describes the ways in which decorative glass products are consistent with the intent of the LEED Rating System. Although individual building products do not in themselves constitute conformance to the LEED criteria, depending on the amount and type of glass used in a project, this versatile material has great potential to help achieve LEED credits. The information contained in this paper has been developed using general or typical information on various decorative glass products. More specific information and performance data can be obtained through individual manufacturers that produce decorative glass products. Please visit the Glass Association of North America website at for a list of member companies and a description of the types of products that are produced by each. Although decorative glass can be used on a project in many forms, is it critical that products conform to recognized standards to ensure the integrity of the building or space. Applicable Standards: The standards listed below are the most applicable to the various decorative glass products contained in this document; however, this is not an exhaustive list. For the complete directory of ASTM Standards, visit Flat glass products to comply with ASTM C 1036 Standard Specification for Flat Glass Heat treated glass products to comply with: o ASTM C 1048 Standard Specification for Heat Treated Flat Glass Kind HS, Kind FT, Coated and Uncoated Glass o ASTM C 1652 Standard Test Method for Measuring Optical Distortion in Flat Glass Products Using Digital Photography of Grids Page 1 of 23

2 o ANSI Z American National Standards Institute (ANSI) American National Standard for Safety Glazing Materials Used in Buildings Safety Performance Specifications and Methods of Test o CAN/CGSB 12.1 M90 Canadian General Standards Board (CGSB) Tempered or Laminated Safety Glass o 16CFR1201, Category II U.S. Government Code of Federal Regulations Part 1201 Safety Standard for Architectural Glazing Materials Laminated glass products to comply with: o ASTM C 1172 Standard Specification for Laminated Architectural Flat Glass o ANSI Z American National Standards Institute (ANSI) American National Standard for Safety Glazing Materials Used in Buildings Safety Performance Specifications and Methods of Test o CAN/CGSB 12.1 M90 Canadian General Standards Board (CGSB) Tempered or Laminated Safety Glass o 16CFR1201, Category II U.S. Government Code of Federal Regulations Part 1201 Safety Standard for Architectural Glazing Materials Glass coated with ceramic (inorganic) coatings to comply with: o ASTM C 346 Standard Test Method for 45 deg Specular Gloss of Ceramic Materials o ASTM C 724 Standard Test Method for Acid Resistance of Ceramic Decorations on Architectural Type Glass o ASTM C 1649 Standard Practice for Instrumental Transmittance Measurement of Color for Flat Glass, Coated and Uncoated o ASTM C 1650 Standard Practice for Instrumental Reflectance Measurement of Color for Flat Glass, Coated and Uncoated o ASTM D 523 Standard Test Method for Specular Gloss Glass coated with organic coatings to comply with: o ASTM D3359 Standard Test Methods for Measuring Adhesion by Tape Test Bent glass to comply with ASTM C 1464 Standard Specification for Bent Glass Mirror products to comply with ASTM C 1503 Standard Specification for Silvered Flat Glass Mirror Insulating glass units to comply with: o ASTM E 2188 Standard Test Method for Insulating Glass Unit Performance o ASTM E 2190 Standard Test Method for Insulating Glass Unit Performance and Evaluation This document is intended to provide general information only. The Glass Association of North America does not make any warranty, either expressly or implied, as to the suitability or completeness of the information contained herein. Page 2 of 23

3 LEED Category: Energy and Atmosphere Credit: EA Credit 1: Optimize Energy Performance LEED Credit Range: 1 19 points (NC & Schools), 3 21 points (CS) Intent: To achieve increasing levels of energy performance beyond the prerequisite standard to reduce environmental and economic impacts associated with excessive energy use. Requirements: Select one of the three compliance path options described below. Project teams documenting achievement using any of the three options are assumed to be in compliance with EA Prerequisite 2: Minimum Energy Performance. Option 1 Whole Energy Building Simulation (1 19 points for NC & Schools, 3 21 points for CS) Demonstrate a percentage improvement in the proposed building performance rating compared with the baseline building performance rating. Calculate the baseline building performance according to Appendix G of ANSI/ ASHRAE/IESNA Standard (with errata but without addenda) using a computer simulation model for the whole building project. Points are awarded for New Buildings, Existing Building Renovations, NC & Schools and Core & Shell as outlined in the table in the Reference Guide. All other credit criteria and compliance measures for this credit are described in detail in the LEED Reference Guide for Green Building Design and Construction, 2009 Edition. Option 2 Prescriptive Compliance Path: ASHRAE Advanced Energy Design Guide (1 point) Comply with the prescriptive measures of the ASHRAE Advanced Energy Design Guide appropriate to the project scope, outlined in the LEED Reference Guide for Green Building Design and Construction, 2009 Edition. Project teams must comply with all applicable criteria as established in the Advanced Energy Design Guide for the climate zone in which the building is located. PATH 1. ASHRAE Advanced Energy Design Guide for Small Office Buildings 2004 The building must meet the following requirements: Less than 20,000 sq ft Office occupancy PATH 2. ASHRAE Advanced Energy Design Guide for Small Retail Buildings 2006 The building must meet the following requirements: Less than 20,000 sq ft Retail occupancy Page 3 of 23

4 PATH 3. ASHRAE Advanced Energy Design Guide for Small Warehouses and Self Storage Buildings 2008 The building must meet the following requirements: Less than 50,000 sq ft Warehouse or self storage occupancy Schools. Option 2. Prescriptive Compliance Path: Advanced Energy Design Guide for K 12 School Buildings (1 point) Comply with all the prescriptive measures identified in the Advanced Energy Design Guide for K 12 School buildings. Projects using Option 2 must be less than 200,000 square feet. Option 3 Prescriptive Compliance Path: Advanced Buildings Core Performance Guide (1 3 points) Comply with the prescriptive measures identified in the Advanced Buildings Core Performance Guide developed by the New Buildings Institute. The building must meet the following requirements: Less than 100,000 sq ft Comply with Section 1: Design Process Strategies, and Section 2: Core Performance Requirements Health care, warehouse or laboratory projects are ineligible for the path (for NC & CS Projects) Points achieved under Option 3 (1 point): 1 point is available for all projects (office, school, public assembly and retail projects) less than 100,000 sq ft that comply with Sections 1 and 2 of the Core Performance Guide Up to 2 additional points are available to projects that implement performance strategies listed in Section 3: Enhanced Performance. For every 3 strategies implemented from this section, 1 pint is available The following strategies are addressed by other aspects of LEED and are not eligible for additional points under EA Credit 1: o 3.1 Cool Roofs o 3.8 Night Venting o 3.13 Additional Commissioning Exemplary Performance: Option 1. Projects that use Option 1 and demonstrate a percentage improvement in the proposed building performance rating compared with the baseline building performance rating per ASHRAE by the following minimum energy cost savings percentages will be considered for 1 additional point under the Innovation in Design category: New buildings: 50% Existing Building Renovation: 46% Options 2 & 3 Not available under the Innovation in Design category. Page 4 of 23

5 USGBC LEED CI Variation: EQ Credit 1 is split into categories as follows: EQ Credit 1.1: Optimize Energy Performance: Lighting Power (1 5 points) EQ Credit 1.2: Optimize Energy Performance: Lighting Controls (1 3 points) EQ Credit 1.3: Optimize Energy Performance: HVAC (5 10 points) EQ Credit 1.4: Optimize Energy Performance: Equipment & Appliances (1 4 points) CaGBC LEED NC Variation: (1 10 points) CaGBC LEED CI Variation: EQ Credit 1 is split into categories as follows: EQ Credit 1.1: Optimize Energy Performance: Lighting Power (1 3 points) EQ Credit 1.2: Optimize Energy Performance: Lighting Controls (1 point) EQ Credit 1.3: Optimize Energy Performance: HVAC (1 2 points) EQ Credit 1.4: Optimize Energy Performance: Equipment & Appliances (1 2 points) Decorative Glass Contribution: This credit refers to strategies to optimize energy usage and performance. Four fundamental strategies are used to increase energy performance: reduce demand, harvest free energy, increase efficiency and recover waste energy. The use of glass in both the building envelope and interior components aids in harvesting site energy by increasing daylighting properties throughout the space and reducing the requirement for electric lighting. Skylight and curtain wall performance can be enhanced through the right combination of glass construction, tints, and coatings. Adding decorative components to the glass surface also provides a measure of control to the light being introduced into each area. In addition, Low E and other solar control types of glass on the exterior of a building will increase the natural lighting while limiting the thermal effects of infrared energy and solar heat gain. This has the potential to generate savings from lower energy use, smaller equipment requirements as well as reduced space needs for mechanical and electrical equipment. Furthermore, when performing energy modeling calculations manually operated shading devices such as blinds or window shades are ineligible under this credit. The permanent application of decorative techniques allow for this type of solar control to be included in the calculations. Page 5 of 23

6 Potential Strategies Involving Decorative Glass Reduce solar heat gain through exterior glazing parameters and reduce energy use. Maximize daylight harvesting to reduce the requirement for electric light Types of Decorative Glass U channel Bent glass Possible Applications Exterior glazing insulating units in conjunction with low e or reflective glass Exterior vision glazing with patterns Exterior fins/sunshades Operable louvers Atria Skylights Clerestory glazing Courtyards Energy efficient exterior glazing Provide glare control to increase lighting quality Reduce energy required for ventilation by providing demand control natural ventilation Provide interior components to increase the daylight penetration deeper into the space Sandblasted/carved glass Translucent coatings Decorative film applications enamels or organic coatings Translucent coatings Decorative film applications Fused, slumped or cast glass Stained glass Bent glass Interior sun shading Interior glazing / partitions Light shelves Light redirecting glazing Glass furniture components Operable windows Glass stairways and flooring Glass railings and balustrades Interior glazing / partitions Furniture components Demountable partitions or sliding walls Page 6 of 23

7 LEED Category: Materials and Resources Credit: MR Credit 4.1: Recycled Content 10% (post consumer + ½ pre consumer) LEED Credit Range: 1 point Credit: MR Credit 4.2: Recycled Content 20% (post consumer + ½ pre consumer) LEED Credit Range: 1 additional point Intent: Increase demand for building products that incorporate recycled content materials, thereby reducing impacts resulting from extraction and processing of virgin materials. Requirements: Use materials with recycled content such that the sum of post consumer recycled content plus one half of the pre consumer content constitutes at least 10% (or 20%) (based on cost) of the total value of the materials in the project. Exemplary Performance: Project teams may earn an Innovation in Design credit for exemplary performance by achieving a total recycled content value of 30% or more. USGBC LEED CI Variation: None CaGBC LEED NC Variation: MR Credit 4.1: Recycled Content: 7.5% (post consumer + ½ post industrial) MR Credit 4.2: Recycled Content: 15% (post consumer + ½ post industrial) Intent: Increase demand for building products that incorporate recycled content materials, therefore reducing impacts resulting from extraction and processing of new virgin materials and by passing energy and greenhouse gas intensive industrial and manufacturing processes. CaGBC LEED CI Variation: MR Credit 4.1: Recycled Content: 7.5% (post consumer + ½ post industrial) MR Credit 4.2: Recycled Content: 15% (post consumer + ½ post industrial) Intent: Increase demand for building products that incorporate recycled content materials, therefore reducing impacts resulting from extraction and processing of new virgin materials and by passing energy and greenhouse gas intensive industrial and manufacturing processes. Decorative Glass Contribution Although float glass manufacturers typically use 20% pre consumer recycled materials in their manufacturing process, for the purpose of this LEED Credit, this is considered reused rather than recycled material and is specifically excluded for credit. Some decorative glass manufacturers and glass artists, however, use recycled glass in their own product offerings. Consult with your decorative glass supplier to determine if this credit is applicable to their products. Although LEED Credits do not apply, some types of decorative glass are completely recyclable at the end of their useful life if not previously contaminated with glazing materials. Examples of this are clear and cast glass, satin etch and glass silkscreened with ceramic enamels or with digital ceramic images Page 7 of 23

8 applied. Laminated glass, mirror and some other types of coatings are not recyclable. Interested parties are encouraged to contact their local recycling facilities for information on the recyclability of specific products. Potential Strategies Involving Decorative Glass Provide interior finishings made from recycled glass Types of Decorative Glass Fused or slumped glass Cast glass Decorative glass tiles Possible Applications Feature walls Glass counter tops / desk tops Glass art installations Furniture components Doors and windows Demountable partition systems Page 8 of 23

9 LEED Category: Indoor Environmental Quality Credit: IEQ Credit 6.1: Controllability of Systems: Lighting (not available for CS) LEED Credit Range: 1 point Intent: Provide a high level of lighting system control by individual occupants or groups in multioccupant spaces (i.e. classrooms or conference areas) and promote their productivity, comfort and wellbeing. Requirements: Provide individual lighting controls for 90% (minimum) of the building occupants to enable adjustments to suit individual task needs and preferences. AND Provide light system controllability for all shared multi occupant spaces to enable adjustments that meets group needs and preferences. Exemplary Performance: This credit is not eligible for exemplary performance under the Innovation in Design section. USGBC LEED CI Variation: None CaGBC LEED NC Variation: EQ Credit 6.1: Controllability of Systems: Perimeter Spaces EQ Credit 6.2: Controllability of Systems: Non Perimeter Spaces Intent: Provide a high level of thermal, ventilation and lighting system control by individual occupants or specific groups in multi occupant spaces (i.e. classrooms or conference areas) to promote the productivity, comfort and well being of building occupants. Requirements: EQ Credit 6.1: Provide at least an average of one operable window and one lighting control zone per 18.5m² (200 ft²) for all regularly occupied areas within 5m (15 ft) of the perimeter wall. Requirements: EQ Credit 6.2: Provide controls for each individual for airflow, temperature and lighting for at least 50% of the occupants in non perimeter, regularly occupied areas. CaGBC LEED CI Variation: None Decorative Glass Contribution: This credit refers to adjustable lighting for individual tasks or in common areas. Integration of surface materials selection (i.e. high reflectance surfaces) and lighting design may create opportunities to reduce the number of installed lighting fixtures. Daylighting can be integrated within the ambient lighting scheme to compensate for the reduced footcandle levels. When daylighting is used as a component of the lighting design, glare control is also necessary. Page 9 of 23

10 Potential Strategies Involving Decorative Glass Provide high reflectance surfaces to coordinate with lighting design Provide glare control as a component of daylighting strategy Provide interior components to increase the daylight penetration deeper into the space Types of Decorative Glass Laminated glass with decorative interlayers Glass coated with ceramic enamels or organic coatings Back painted glass Decorative mirror Acid etched mirror Sandblasted/carved glass Translucent coatings Decorative film applications enamels or organic coatings Fused, slumped or cast glass Bent glass Stained glass Possible Applications Laminated glass ceiling tiles with diffused or light colored interlayers (90% or greater reflectivity) Light colored glass wall cladding Interior light shelves Interior sun shading Interior partitions Light shelves Light redirecting glazing Exterior fins / canopies / sun shading Acid etched rear projection screens Doors and windows Demountable partition systems Glass stairways and flooring Glass railings and balustrades Interior glazing / partitions Furniture components Interior doors Page 10 of 23

11 LEED Category: Indoor Environmental Quality Credit: IEQ Credit 8.1: Daylight & Views: Daylight 75% of Spaces LEED Credit Range: 1 2 points (NC & CS), 1 3 points (Schools) Intent: To provide for the building occupants a connection between indoor spaces and the outdoors through the introduction of daylight and views into the regularly occupied areas of the building. Requirements: Option 1: Simulation Demonstrate through computer simulations that 75% or more of all regularly occupied spaces achieve daylight illuminance levels of a minimum of 25 footcandles (fc) and a maximum of 500 fc in a clear sky condition on September 21 at 9 a.m. and 3 p.m.; areas with illuminance levels below or above the range do not comply. However, design that incorporate view preserving automated shades for glare control may demonstrate compliance for only the minimum 25 fc illuminance level. Option 2: Prescriptive For the Side lighting daylight zone: Achieve a value, calculated as the product of the visible light transmittance (VLT) and window to floor area ratio (WFR) of daylight zone and The window area included in the calculation must be at least 30 inches above the floor. The ceiling must not obstruct a line in section that joins the window head to a line on the floor that is parallel to the plane of the window; is twice the height of the window head above the floor in, distance from the plane of the glass as measured perpendicular to the plane of the glass. Provide sunlight redirection and/or glare control devices to ensure daylight effectiveness. For Top lighting Daylight Zone: The daylight zone under a skylight is the outline of the opening beneath the skylight, plus in each direction the lesser of: o 70% of the ceiling height, OR o ½ the distance to the edge of the nearest skylight, OR o The distance to any permanent opaque partition (if transparent show VLT) that is farther than 70% of the distance between the top of the partition and the ceiling. Achieve skylight roof coverage between 3% and 6% of the roof area with a minimum 0.5 VLT. The distance between the skylights must not be more than 1.4 times the ceiling height. A skylight diffuser, if used, must have a measured haze value of greater than 90% when tested according to STM D1003. Avoid direct line of sight to the skylight diffuser. Option 3: Measurement Demonstrate, through records of indoor light measurements, that a minimum daylight illumination level of 25 footcandles has been achieved in at least 75% of all regularly occupied areas. Measurements must be taken on a 10 foot grid for all occupied spaces and shall be recorded on building floor plans. Page 11 of 23

12 Only the square footage associated with the portions of rooms or spaces meeting the minimum illumination requirements may be counted in the calculations. For all projects pursuing this option, provide daylight redirection and/or glare control devices to avoid high contrast situations that could impede visual tasks. Exceptions for areas where tasks would be hindered by daylight will be considered on their merits. Option 4: Combination Any of the above calculation methods may be combined to document the minimum daylight illumination in at least 75% of all regularly occupied spaces. The different methods used in each space must be clearly recorded on all building plans. In all cases, only the square footage associated with the portions of rooms or spaces meeting the requirements can be applied toward the total area calculation required to qualify for this credit. In all cases, provide glare control devices to avoid high contrast situations that could impede visual tasks. Exceptions for areas where tasks would be hindered by the use of daylight will be considered on their merits. A well designed daylight building is estimated to reduce lighting energy use by 50 to 80%. (Sustainable Building Technical Manual, chapter IV.7, page 90). Exemplary Performance: (NC & CS) This credit may be eligible for exemplary performance under the Innovation in Design section if the project achieves 95% daylighting based on the credit requirements and guidelines. (Schools) This credit may be eligible for exemplary performance under the Innovation in Design section if the project achieves daylighting for 90% of all classrooms and 95% daylighting in all other regularly occupied non classroom spaces based on the credit requirements and guidelines. USGBC LEED Variation Schools: OR Classroom Spaces Points 75% 1 90% 2 75% of all other regularly occupied spaces (1 additional point). Project teams can achieve a point for these other spaces only if they have also achieved at least 1 point for classroom spaces. USGBC LEED CI Variation Schools: Classroom Spaces Points 75% 1 90% 2 Page 12 of 23

13 CaGBC LEED NC Variation: None CaGBC LEED CI Variation: None Decorative Glass Contribution: This credit addresses the availability of daylight to a building s occupants. When designing for maximum daylight, designers must evaluate and balance a number of environmental factors, such as heat gain and loss, glare control, visual quality and variations in daylight availability. Decorative glass can be used in a variety of applications and help achieve LEED credits by increasing the daylight factor within a building. By using glass to provide the connection between indoor occupants and the outdoors, building designers can also offer the added benefits of a low maintenance product and superior sound control. Many decorative techniques can also be used as glare control or to vary the degree of light transmission, making decorative glass a versatile material for use in floors, walls, ceilings, and furniture, as well as in the more traditional doors and windows. Potential Strategies Involving Decorative Glass Maximize daylight harvesting to provide the connection between indoor spaces and the outdoors Types of Decorative Glass Channel glass Bent glass Possible Applications Atria Skylights Clerestory glazing Courtyards Energy efficient exterior glazing Interior glazing / partitions Doors and windows Reduce heat gain/loss through exterior glazing parameters and reduce energy use Provide interior components to increase daylight factor Provide interior components to increase the daylight penetration Sandblasted/carved glass Bent glass Fused, slumped or cast glass Low E or reflective exterior glazing Exterior vision glazing with silkscreened patterns Exterior fins / sunshades Operable louvers Exterior light shelves Interior light shelves Light redirecting glazing High reflectance ceiling or wall tiles Interior glazing / partitions Conference room and office walls with privacy decoration that still allows light penetration Interiors doors Demountable partitions or sliding walls Glass stairways and flooring Glass railings and balustrades Page 13 of 23

14 deeper into the space Provide glare control to increase lighting quality Reduce the incidents of bird collisions with exterior glazing enamels or organic coatings Stained glass Bent glass Acid etched glass Sandblasted/carved glass Translucent coatings Decorative film applications enamels or organic coatings enamels or organic coatings Decorative film applications Sandblasted/carved glass Interior glazing / partitions Furniture components Interior doors Demountable partitions or sliding walls Interior sun shading Interior glazing / partitions Light shelves Louvers Light redirecting glazing Glass furniture components Exterior sun shading / fins Acid etched rear projection screens Demountable partitions or sliding walls Doors and windows Exterior sun shading / fins Exterior vision glazing with silkscreened patterns Exterior glazing with reduced apparent transparency and reflectivity through decorative techniques Page 14 of 23

15 LEED Category: Indoor Environmental Quality Credit: IEQ 8.2: Daylight & Views: Views for 90% of Spaces LEED Credit Range: 1 point Intent: Provide building occupants a connection to the outdoors through the introduction of daylight and views into the regularly occupied areas of the building. Requirements: Achieve a direct line of sight to the outdoor environment via vision glazing between 30 inches and90 inches above the finish floor for building occupants in 90% of all regularly occupied areas. Determine the area with direct line of sight by totaling the regularly occupied square footage that meets the following criteria: In plain view, the area is within sight lines drawn from perimeter vision glazing. In section view, a direct sight line can be drawn from the area to perimeter vision glazing. The line of sight may be drawn through interior glazing. For private offices, the entire square footage of the office may be counted if 75% or more of the area has direct line of sight to perimeter vision glazing. For classrooms and other multi occupant spaces, the actual square footage with a direct line of sight to perimeter vision glazing is counted. Additional requirement for Core & Shell: The core and shell design must incorporate a feasible tenant layout(s) per the default occupancy counts (or some other justifiable occupancy count) that can be used in the analysis of this credit. Exemplary Performance: Exemplary performance may be demonstrated for this credit by meeting 2 of the following 4 measures: 1. 90% or more of regularly occupied spaces have multiple lines of sight to vision glazing in different directions at least 90 degrees apart % or more of regularly occupied spaces have views that include views of at least 2 of the following 3 options: 1) vegetation, 2 human activity, or 3) objects at least 70 feet from the exterior of the glazing % or more of regularly occupied spaces have access to unobstructed views located within the distance of 3 times the head height of the vision glazing % or more of regularly occupied spaces have access to views with a view factor of 3 or greater. USGBC LEED CI Variation: IEQ Credit 8.2: Daylight & Views: Views for Seated Spaces. Section View Requirement: In section view, a direct sight line can be drawn from a point 42 inches above the floor (typical seated eye height) to perimeter vision glazing. Page 15 of 23

16 CaGBC LEED NC Variation: Additional requirements: Areas directly connected to perimeter windows must have a glazing to floor area ratio of at least For multi occupant spaces, if the view area of any applicable room exceeds 90%, the entire square footage of the room can be counted. Parts of the floor area with horizontal view angles of less than 10 at 1.27m (50 ) above the floor cannot be included in this calculation. Areas not directly connected to perimeter windows must have a horizontal view angle of at least 10 at 1.27m (50 ) above the floor involving 50% or more of the floor area. If a room meets these requirements then the entire room area is considered to meet the view requirement. CaGBC LEED CI Variation: EQ Credit 8.2: Daylight & Views: Daylight for 90% of Spaces: Follow the requirements for EQ Credit 8.1 for a minimum of 90% of regularly occupied spaces. Page 16 of 23

17 Potential Strategies Involving Decorative Glass Use glass to provide the connection between indoor occupants and the outdoors. Types of Decorative Glass U channel Bent glass Possible Applications Atria Skylights Clerestory glazing Courtyards Energy efficient exterior glazing Doors and windows Develop indoor green spaces and incorporate glass components to increase viewing area. Bent glass Atria Skylights Clerestory glazing Courtyards Energy efficient exterior glazing Interior doors Utilize interior glazing to increase areas with a direct line of sight to the outdoors, adding decorative components to reduce glare and add a measure of privacy. Provide colors, textures and patterns applied to glass to bring the effect of nature into the building's interior increasing overall satisfaction of occupants with their work environment. Bent glass Sandblasted/carved glass Translucent coatings Decorative film applications Stained glass Sandblasted/carved glass Back painted glass Fused, slumped and cast glass Stained glass Acid etched mirror Glass stairways and flooring Glass railings and balustrades Interior glazing / partitions Furniture components Glass signage Interior doors Demountable partitions or sliding walls Atria Skylights Clerestory glazing Courtyards Glass stairways and flooring Glass railings and balustrades Interior glazing / partitions Furniture components Glass wall cladding Demountable partitions or sliding walls Interior doors and door inserts Page 17 of 23

18 LEED Category: Indoor Environmental Quality Credit: IEQ 9: Enhanced Acoustical Performance (for Schools only) LEED Credit Range: 1 point Intent: To provide classrooms that facilitates better teacher to student and student to student communications through effective acoustical design. Requirements: Sound Transmission Design the building shell, classroom partitions and other core learning space partitions to meet the Sound Transmission Class (STC) requirements of ANSI Standard S , Acoustical Performance Criteria, Design Requirements and Guidelines for Schools, except windows, which must meet an STC rating of at least 35. AND Background Noise Reduce background noise level to 40 dba or less from heating, ventilating and air conditioning (HVAC) systems in classrooms and other core learning spaces. Exemplary Performance: This credit may be eligible for exemplary performance under the Innovation in Design section if the project achieves an outdoor background noise level of 55 dba for playgrounds and 60 dba for athletic fields and all other schools grounds, or an indoor noise level of 35 dba. USGBC LEED CI Variation: N/A CaGBC LEED NC Variation: N/A CaGBC LEED CI Variation: N/A Decorative Glass Contribution: Many types of decorative glass products are available in laminated, insulating, laminated insulating or double glazed form. The use of decorative glass in these types of glass systems allows for the combination of enhanced acoustical control with energy reduction, daylight harvesting, glare control and the introduction of views. Page 18 of 23

19 Potential Strategies Involving Decorative Glass Increase the STC rating of exterior glass to mask exterior background noise. Types of Decorative Glass Double glazed, insulating or laminated glass containing: Decorative interlayers Possible Applications Skylights Clerestory glazing Energy efficient exterior glazing Doors and windows Increase the STC rating of interior glass to mask both interior and exterior background noise. Double glazed, insulating or laminated glass containing: Decorative interlayers Sandblasted/carved glass Translucent coatings Decorative film applications Clerestory glazing Courtyards Interior glazing / partitions Furniture components Glass wall cladding Interior doors and door inserts Demountable partitions or sliding walls to separate instructional areas Page 19 of 23

20 POTENTIAL ID CREDITS LEED Category: Innovation in Design Credit: ID 1: Innovation in Design LEED Credit Range: 1 5 points (1 4 points for Schools) Intent: To provide design teams and projects the opportunity to achieve exceptional performance above the requirements set by the LEED Green Building Rating System and/or innovative performance in Green Building categories not specifically addressed by the LEED Green Building Rating System. Requirements: Credit can be achieved through any combination of the paths below: PATH 1. Innovation in Design (1 5 points for NC & CS, 1 4 points for Schools) in the LEED 2009 for New Construction and Major Renovations, LEED 2009 for Core and Shell Development, or LEED 2009 for Schools Rating System. One point is awarded for each innovation achieved. No more than 5 points (for NC & CS) and 4 points (for Schools) under IDc1 may be earned through PATH 1 Innovation in Design. Identify the following in writing: The intent of the proposed innovation credit. The proposed requirement of compliance. The proposed submittals to demonstrate compliance. The design approach (strategies) used to meet the requirements. PATH 2. Exemplary Performance (1 3 points) Achieve exemplary performance in an existing LEED 2009 for Schools prerequisite or credit that allows exemplary performance as specified in the LEED Reference Guide for Green Building Design & Construction, 2009 Edition. An exemplary performance po9int may be earned for achieving double the credit requirements and/or achieving the next incremental percentage threshold of an existing credit in LEED. One point is awarded for each exemplary performance achieved. No more than 3 points under IDc1 may be earned through PATH 2 Exemplary Performance. USGBC LEED CI Variation: None CaGBC LEED NC Variation: 1 4 points available CaGBC LEED CI Variation: 1 4 points available Page 20 of 23

21 Potential ID Credit #1: LEED Category: Indoor Environmental Quality Credit: ID 1: Innovation in Design LEED Credit Range: 1 point Intent: Reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well being of installers and occupants. Requirement: Develop a comprehensive strategy to reduce VOC levels by selecting items such as materials, furniture, maintenance coatings and others that introduce low or no VOC s and that meet or exceed the South Coast Air Management District Rule Demonstrate extensive use of these products and verify that their use is not a code requirement or industry standard practice. Decorative Glass Contribution: The intent of this credit is to limit VOC s in the building through the selection of materials, furniture, maintenance coatings and other items that are not covered by IEQ Credit Decorative glass offers many products that have factory applied coatings with no VOC s. The use of decorative glass in place of walls, doors, floors, ceilings and furniture provides a wide range of design options with no VOC s being introduced into the site. Unlike drywall or millwork, decorative glass products need no repainting, refinishing or similar maintenance which eliminates VOC s and irritating fumes from periodic maintenance. Glass coatings contain no hazardous content and do not generate hazardous waste during construction unlike solvent based paints and adhesives. They also require no hazardous materials to clean up after installation or during maintenance. Potential Strategies Involving Decorative Glass Replacement of traditional building materials Types of Decorative Glass Sandblasted/carved glass Back painted glass Fused, slumped and cast glass Stained glass Decorative mirror Acid etched mirror Possible Applications Glass stairways and flooring Glass railings and balustrades Interior glazing / partitions Furniture components Glass wall cladding Glass signage Elevator cab interiors Glass canopies Feature walls Demountable partitions or sliding walls Glass counter tops / desk tops Doors and door inserts Ceiling tiles Operable windows & louvers Page 21 of 23

22 Potential ID Credit #2: Intent: To build a comprehensive, interactive educational program within the LEED certified building to demonstrate and promote the use of sustainable building features and practices. Decorative Glass Contribution: An educational outreach program could include features such as a visitor s center, interactive display or video, comprehensive signage program or built in windows to view the energy saving components of the building. The durability, design flexibility and low maintenance properties of decorative glass make this a valuable material to use for protecting or enhancing the features of the space or to impart information through signage and exhibits. Potential Strategies Involving Decorative Glass Use decorative glass signage to illustrate the sustainable design features within the building Types of Decorative Glass Sandblasted/carved glass Decorative film applications Back painted glass Fused, slumped and cast glass Possible Applications Decorative glass signage Wayfinding components Use decorative glass screens mounted in the walls or floors to impart information as well as protect interactive displays, televisions or computer screens. Decorative film applications Back painted glass Decorative glass signage Wayfinding components Glass screens mounted in the floors or walls Exhibit features Incorporate built in windows to view the energy saving mechanical equipment or other green components of the building Sandblasted/carved glass Decorative film applications Viewing windows that contain information/ instruction on the components being viewed Page 22 of 23

23 LEED Category: Regional Priority Credit: RP 1: Regional Priority LEED Credit Range: 1 4 points Intent: To provide an incentive for the achievement of credits that address geographically specific environmental priorities. Requirements: Earn 1 4 of the 6 Regional Priority credits identified by the USGBC regional councils and chapters as having environmental importance for a project s region. A database of Regional Priority credits and their geographic applicability is available on the USGBC website; One point is awarded for each Regional Priority credit achieved; no more than 4 credits identified as Regional Priority credits may be earned. Projects outside of the U.S. are not eligible for Regional Priority credits. Understanding Regional Priority Credits: RPCs are not new LEED credits, but instead are existing credits that USGBC chapters and regional councils have identified as being particularly important for their areas. The incentive to achieve the credits is in the form of a bonus point. If an RPC is earned, then a bonus point is awarded to the project s total points. Project teams do not need to attempt these credits in addition to the existing LEED credits they are attempting. Upon project registration, LEED Online automatically determines a project s RPCs based on it ZIP code. If a project earns an RPC, it will also earn the associated bonus point. For more information and a complete list of RPCs available by ZIP code, visit the USGBC website at Page 23 of 23

Alpen Windows - LEED Impact Analysis

Alpen Windows - LEED Impact Analysis ALPEN WINDOWS MATERIALS: Energy Efficient Windows Alpen Windows - LEED Impact Analysis SECTION I. PRODUCT IDENTIFICATION Product Name: Alpen Windows Manufacturer: Alpen High Performance Products 6268 Monarch

More information

LEED And Your Indoor Environment

LEED And Your Indoor Environment LEED And Your Indoor Environment An overview of LEED v3 and Indoor Air Quality David McCauley, CIE Council Certified Indoor Environmentalist ACAC CIE #1008005 USGBC's Mission To transform the way buildings

More information

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects 3.0 Statement Columbia Skylights Statement for New Construction (NC) Version 3.0 Credit Documentation The Leadership in Energy and Environmental Design () Green Building Rating System promotes the adoption

More information

LEED v4 Building Design and Construction Quiz #8 EQ

LEED v4 Building Design and Construction Quiz #8 EQ LEED v4 Building Design and Construction Quiz #8 EQ 1. Which of these is considered an unoccupied space? [Choose three] A. School classroom B. Mechanical room C. Meeting room D. Locker room E. Restroom

More information

LEED Application Guide for Multiple Buildings and On Campus Building Projects

LEED Application Guide for Multiple Buildings and On Campus Building Projects LEED Application Guide for Multiple Buildings and On Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011

More information

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits 1 Thermiser Insulated Rolling Doors Earning LEED v4 Credits Cookson s Thermiser Insulated Rolling Doors can provide a significant

More information

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled:

Errata Sheet. LEED for Schools Reference Guide First Edition for the document titled: Errata Sheet for the document titled: LEED for Schools Reference Guide First Edition 2007 Notes: Updates to this document are posted on the LEED for Schools Rating System page and the Reference Guide electronic

More information

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods LEED An Introduction to LEED V3 2009 LEED Leadership in Energy and Environmental Design A voluntary, consensus-based national standard for developing high-performance, sustainable buildings and neighborhoods

More information

Cornell Rolling Counter Fire Doors Comprehensive Guide to Earning LEED v4 Credits

Cornell Rolling Counter Fire Doors Comprehensive Guide to Earning LEED v4 Credits Cornell Rolling Counter Fire Doors Comprehensive Guide to Earning LEED v4 Credits 1 Cornell Rolling Counter Fire Doors Earning LEED v4 Credits Cornell Rolling Counter Fire Doors can provide a significant

More information

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP LEED 2009 for Commercial Interiors Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP Homes Commercial Interiors Core & Shell New Construction Schools Healthcare Existing Building Operations

More information

Balco, Inc. Stair Nosings

Balco, Inc. Stair Nosings Balco, Inc. Stair Nosings Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. Stair Nosings Contributes to LEED Credits Zero maintenance, reducing

More information

Balco, Inc. PC Series Partition Closure Systems

Balco, Inc. PC Series Partition Closure Systems Balco, Inc. PC Series Partition Closure Systems Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. PC Series Partition Closure Systems Contributes

More information

Acid-etched Glass for Exterior Applications A Unique Way to Move Light!

Acid-etched Glass for Exterior Applications A Unique Way to Move Light! cid-etched Glass for Exterior pplications Unique Way to Move Light! University of Pennsylvania Philadelphia, P 6 mm custom pattern on position Because acid-etching is not a coating, its resistance properties

More information

Decoustics and LEED Leadership in Energy and Environmental Design

Decoustics and LEED Leadership in Energy and Environmental Design Decoustics and LEED Leadership in Energy and Environmental Design Buildings fundamentally impact people s lives and the health of the planet. In the United States, buildings use one-third of the total

More information

Going Beyond LEED : Achieving Sustainable Design with Advanced Fire Rated Glass Systems

Going Beyond LEED : Achieving Sustainable Design with Advanced Fire Rated Glass Systems Going Beyond LEED : Achieving Sustainable Design with Advanced Fire Rated Glass Systems By SAFTIFIRST Fire Rated Glazing Solutions Abstract: This white paper provides readers with an understanding of how

More information

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION Genentech Building 20 Office LEED-CI Gold Above and Beyond A LEED Gold 50,00 s.f. tenant improvement, the space was originally designed with a goal to achieve LEED silver certification. Innovative approaches

More information

QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification

QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification QUALITY SUSTAINS YKK AP Guide to LEED v4 Certification Entrances Storefronts Curtain Walls Sun Controls Windows Balcony Doors SUSTAINABLE BUILDING ENVELOPES We at YKK AP America Inc. (YKK AP) follow our

More information

LEED Analysis of the Knight Management Center. Energy & Atmosphere. Materials & Resources

LEED Analysis of the Knight Management Center. Energy & Atmosphere. Materials & Resources LEED of the Knight Management Center Energy & Atmosphere Materials & Resources Energy & Atmosphere: 17 possible points LEED-NC Scorecard LEED for New Construction v2.2 Registered Project Checklist Project

More information

LEED Nc 3.0 Statement

LEED Nc 3.0 Statement LEED Nc 3.0 Statement Version LEED Nc 3.0 Statement The U.S. Green Building Council s Leadership in Energy and Environmental Design (LEED ) New Construction 3.0 program certification is required by many

More information

We make buildings greener. W ith Advanced Architectural Glass. Updated for LEED Version 3

We make buildings greener. W ith Advanced Architectural Glass. Updated for LEED Version 3 E A R N L E E D P O I N T S W H E N Y O U B U I L D W I T H L I G H T T H E S U N G U A R D G U I D E T O L E E D We make buildings greener. W ith Advanced Architectural Glass. Updated for LEED Version

More information

Exemplary Performance

Exemplary Performance Option D. Heat Island Reduction: Non-Roof? Option E. Heat Island Reduction: Roof? 1 2 Option J. Water Use Reduction? Option K. Onsite Renewable Energy? 3 4 Option L. Other Quantifiable Environmental? WE

More information

Daylighting Design 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design

Daylighting Design 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design Daylighting Design 12 th Annual Building Codes Education Conference March 27-30 2017 Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design Lab Montana State University, Bozeman, MT March 30, 2017

More information

Architect's Letter of Assurance

Architect's Letter of Assurance Architect's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing

More information

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS SUSTAINABLE DESIGN FORM 010.901 REV 1211 THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS SUSTAINABLE DESIGN GUIDE StopWaste.Org LEED-NC Platinum Energy Foundation LEED-CI Platinum Adobe East Tower LEED-EB

More information

Light Control and LEED

Light Control and LEED Light Control and LEED How light control helps achieve LEED certification in new construction and major renovations of commercial buildings AIA Program Number LCAL10 1.0 Learning Unit HSW/SD Approved by

More information

optimize daylighting Opportunities

optimize daylighting Opportunities optimize daylighting Opportunities DESIGN STRATEGIES DESIGN STRATEGIES NATURAL LIGHTING FOR ENERGY EFFICIENCY DAYLIGHTING Using indirect natural light to illuminate indoor spaces as an alternative to electric

More information

Research Analysis: Building Envelope and LEED Credits Introduction

Research Analysis: Building Envelope and LEED Credits Introduction : Building Envelope and LEED Credits Introduction Green buildings are no longer a new idea and are quickly becoming the trend in the slowly changing industry of building construction. Even though the essence

More information

GUARDIAN REVEAL. switchable privacy glass. from public view to private space, with the flip of a switch

GUARDIAN REVEAL. switchable privacy glass. from public view to private space, with the flip of a switch GUARDIAN REVEAL switchable privacy glass from public view to private space, with the flip of a switch GUARDIAN REVEAL switchable privacy glass Imagine a visually open space that shifts to a private enclosure

More information

500 WEST PUTNAM AVENUE GREENWICH, CT

500 WEST PUTNAM AVENUE GREENWICH, CT LEED-CI ANALYSIS June 2015 500 WEST PUTNAM AVENUE GREENWICH, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability

More information

LEED for Commercial Interiors

LEED for Commercial Interiors LEED-CI LEED for Commercial Interiors Kim Lam Renee Webley What is the LEED-CI Rating System? The benchmark for tenant improvements of new or existing office space. An integrated design tool that sets

More information

Balco, Inc. Aluminum Expansion Joint Covers

Balco, Inc. Aluminum Expansion Joint Covers Balco, Inc. Aluminum Expansion Joint Covers Applicable Rating Systems: CI - Commercial Interiors RETAIL CI - Retail, Commercial Interiors Balco, Inc. Aluminum Joint Cover Systems Contributes to LEED Credits

More information

What s New in LEED v4

What s New in LEED v4 July 2017 AIA Course Number: LEED17A What s New in LEED v4 A focus on Material & Resources (MR) and Indoor Environmental Quality (IEQ) AIA Registration 2 Armstrong World Industries is a registered provider

More information

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise About LEED Certification The U.S. Green Building Council s LEED green building program

More information

ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM

ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM APRIL 2012 ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM Abu Dhabi Education Council Infrastructure and Facilities Division Jyoti Sharma, Senior Architect, Design Section WHY SUSTAINABILITY IS IMPORTANT UAE

More information

Thomas Brown, Architect, LEED-AP. Part 5 Daylighting Strategies Shading Case Studies

Thomas Brown, Architect, LEED-AP. Part 5 Daylighting Strategies Shading Case Studies Re-Arch: The Initiative for Renewable Energy in Architecture Best Practices in Daylighting & Passive Systems for Smaller Commercial Buildings Project Team: University of Minnesota College of Design (CDes)

More information

Pliteq Inc. - LEED Summary

Pliteq Inc. - LEED Summary Pliteq Inc. - LEED Summary At Pliteq, we re committed to serving the health and safety of both our environment and our community. Pliteq is an engineering company dedicated to providing creative solutions

More information

5.0 Daylighting Analysis (Breathe Study)

5.0 Daylighting Analysis (Breathe Study) 5.0 Daylighting Analysis (Breathe Study) 69 5.0 Daylighting Analysis (Breathe Study) 5.1 Background contains approximately 150 patient recovery rooms. Of these 96 are located around the perimeter of the

More information

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE Amarpreet Sethi College of Architecture and Environmental Design Arizona State University,

More information

This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this

This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this This presentation provides: An overview of the 2013 version of Green Globes plus Compliance details on the lighting related provisions this sustainability standard 1 This presentation is protected. 2 This

More information

Enhancing visual comfort in classrooms through daylight utilization

Enhancing visual comfort in classrooms through daylight utilization Enhancing visual comfort in classrooms through daylight utilization Kleo Axarli and Katerina Tsikaloudaki Laboratory of Building Construction & Physics, Aristotle University of Thessaloniki, Greece Corresponding

More information

real DAYLIGHTING solutions SOLERA

real DAYLIGHTING solutions SOLERA real DAYLIGHTING solutions Port Hawkesbury Civic Centre Architect - Ojolick Associates SOLERA www.advancedglazings.com TAMING the SUN Harnessing the sun s abundant light is a challenge. Avoiding glare,

More information

Section SoundPly LR M25 Acoustic Ceiling Panels

Section SoundPly LR M25 Acoustic Ceiling Panels Section 095126 Acoustic Ceiling Panels PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY A. Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1

More information

GUARDIAN REVEAL SWITCHABLE PRIVACY GLASS

GUARDIAN REVEAL SWITCHABLE PRIVACY GLASS GUARDIAN REVEAL SWITCHABLE PRIVACY GLASS F R O M P U B L I C V I E W T O P R I V AT E S PA C E, W I T H T H E F L I P O F A S W I T C H GUARDIAN REVEAL SWITCHABLE PRIVACY GLASS Imagine a visually open

More information

INTERIOR ENVIRONMENT

INTERIOR ENVIRONMENT CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,

More information

NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS

NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS NEW FOUR STORY MIXED USE RESTAURANT, RETAIL, LODGING, AND OFFICE BUILDING OWNER S PROJECT REQUIREMENTS TABLE OF CONTENTS Introduction Page 2 Project Description Page 2 Owner s Directives Page 4 Design

More information

GlassWall. Movable Partitions

GlassWall. Movable Partitions GlassWall Movable Partitions The right choice has never been more clear. Combining the drama and beauty of glass with the functionality of operable partitions, Hufcor s GlassWall movable partitions allow

More information

LEED version 4 Leadership in Energy and Environmental Design

LEED version 4 Leadership in Energy and Environmental Design LEED version 4 Leadership in Energy and Environmental Design United States Green Building Council Founded in 1993, the United States Green Building Council (USGBC) was the first Green Building Council

More information

Regupol Sonus & SonusWave Underlayment Contrubutions to LEED

Regupol Sonus & SonusWave Underlayment Contrubutions to LEED NC, CS, Schools, Retail, and LEED for Canada: NC MR 4 Use materials with recycle content such that the sum of post-consumer content plus one-half of the pre-consumer content constitutes at least 10% or

More information

LEED Application Guide for Multiple Buildings and On-Campus Building Projects

LEED Application Guide for Multiple Buildings and On-Campus Building Projects LEED Application Guide for Multiple Buildings and On-Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011

More information

City of Richmond Zoning Ordinance Page 12-1

City of Richmond Zoning Ordinance Page 12-1 ARTICLE 12 BUILDING DESIGN AND COMPOSITION Section 12.01 Purpose. High quality architectural design and building composition are important elements in reinforcing a comfortable, human-scale environment,

More information

USGBC & LEED. A Summary of the LEED Development as a primer for LEED ND

USGBC & LEED. A Summary of the LEED Development as a primer for LEED ND USGBC & LEED A Summary of the LEED Development as a primer for LEED ND US Green Building Council USGBC Basic USGBC information LEED (Leadership in Energy and Environmental Design GBCI (Green Building Certification

More information

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system. SECTION 23 01 01 HVAC LEED REQUIREMENTS PART 1 -GENERAL 1.1 WORK INCLUDES A. Compliance with LEED project requirements. B. Coordination of LEED construction phase activities. C. Data gathering of construction

More information

Repair Maintenance Hangar Phase II August 2010

Repair Maintenance Hangar Phase II August 2010 SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include

More information

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX

UBC Technical Guidelines Division Edition Furnishings Page 1 of 1 INDEX UBC Technical Guidelines Division 12 2017 Edition Furnishings Page 1 of 1 INDEX Section 12 00 00 Section 12 20 00 Section 12 30 00 Section 12 35 53 Furnishings Window Coverings and Blinds Fabricated Casework

More information

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS OL REFLECT 2K- Product Rating The product fulfills the requirements for adhesives and sealants and contribute to achieve one LEED credit within IEQ Credit 4.1. The product fulfills the requirements for

More information

LEED Leadership in Energy and Environmental Design

LEED Leadership in Energy and Environmental Design LEED Leadership in Energy and Environmental Design United States Green Building Council (USGBC) Founded in 1993, the United States Green Building Council (USGBC) was the first Green Building Council formed

More information

Climate Analysis. Daylighting uses solar angles, cloud cover/precipitation, and context. Temperature. Humidity. Precipitation. Wind.

Climate Analysis. Daylighting uses solar angles, cloud cover/precipitation, and context. Temperature. Humidity. Precipitation. Wind. Climate Analysis Temperature Humidity Precipitation Wind Cloud Cover Daylighting uses solar angles, cloud cover/precipitation, and context. Solar Energy Daylight Glare Simple Daylight Analysis North Angle

More information

Progressive Design Concepts for the Evolving Learning Environment

Progressive Design Concepts for the Evolving Learning Environment Progressive Design Concepts for the Evolving Learning Environment Learning Objectives 1. Understand how air movement can maximize energy savings and comfort in a range of educational applications. 2. Demonstrate

More information

Knoll and Sustainable Design. Life Chair LEED Credits

Knoll and Sustainable Design. Life Chair LEED Credits Life Chair Overview Life is a light, flexible ergonomic chair designed by Formway Design for Knoll that includes among its multiple awards a Best of NeoCon Gold for Office Seating. Environmental characteristics

More information

35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12%

35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12% Science Center Cabot Library Project LEED CI v4.0 1 Oxford Street, Cambridge, ma LEED Certified Project Profile December 2017 The Science Center Cabot Library project was comprised of renovating the entry,

More information

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including: SECTION 08 81 00 - DECORATIVE GLASS GLAZING PART 1 - GENERAL 1.1 SECTION INCLUDES A. Decorative specialty glass glazing for interior applications, including: GlasPro-BP as Manufactured by GlasPro www.glas-pro.com

More information

Page 1 of 6 Daylighting by Gregg D. Ander, FAIA Southern California Edison Updated by U.S. Department of Energy Federal Energy Management Program (FEMP) Last updated: 08-29-2011 INTRODUCTION Daylighting

More information

THE INTEGRATED APPROACH TIPS FOR DAYLIGHTING WITH WINDOWS

THE INTEGRATED APPROACH TIPS FOR DAYLIGHTING WITH WINDOWS THE INTEGRATED APPROACH TIPS FOR DAYLIGHTING WITH WINDOWS Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain

More information

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations IAS Accreditation Number Company Name Address Contact Name Telephone (651) 636-3835 Effective Date of Scope August 12, 2016 Accreditation Standard ISO/IEC 17025:2005 Conformity Specifications TL-285 849

More information

Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION

Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION SUPPORTING GREEN INITIATIVES WITH INNOVATION As one of the first manufacturers of air movement and control equipment to join the U.S. Green

More information

Spandrel Glass Types and Recommendations

Spandrel Glass Types and Recommendations Introduction Vitro (formerly PPG Industries) has long offered recommendations regarding alternatives for glass spandrel applications. Over the years these recommendations were included in various publications

More information

LIGHTFLEX Tunable-White LED Tubular Daylighting System. Smart. Simple. Sustainable.

LIGHTFLEX Tunable-White LED Tubular Daylighting System. Smart. Simple. Sustainable. LIGHTFLEX Tunable-White LED Tubular Daylighting System Smart. Simple. Sustainable. Why Daylighting? It s natural, and it s free! Intuitively, we all sense that natural daylight is best. It enables our

More information

LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction

LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction Summary Date of Application Path Project Project Address Owner Architect Third Party Third Party Provider

More information

SUPPLEMENT FOR EDGE USER GUIDES V.2.0. Date of Publication: Refer to the EDGE website for the most recently published supplement

SUPPLEMENT FOR EDGE USER GUIDES V.2.0. Date of Publication: Refer to the EDGE website for the most recently published supplement SUPPLEMENT FOR EDGE USER GUIDES V.2.0 Date of Publication: 2017.04.19 Refer to the EDGE website for the most recently published supplement SUPPLEMENT FOR EDGE USER GUIDES VERSION 2.0 INTRODUCTION This

More information

LEED with COLD FORMED STEEL

LEED with COLD FORMED STEEL R&P Supply is a proud member of the U.S. Green Building Council, and strictly adheres to its LEED requirements. Our products will assure you with the highest quality materials while making sure your project

More information

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis Senior Design Project for UNO Design of the International Studies Building: An Environmental Analysis Design Intent Implement Passive & Active design strategies in order to make the building: More Energy

More information

EnOcean Technology and LEED Enabling Sustainability

EnOcean Technology and LEED Enabling Sustainability Rev A 2010-01-22 Prepared by Building Intelligence Group LLC: Paul Ehrlich, PE Jeffrey Seewald, PE (651) 204-0105 info@buildingintelligencegroup.com www.buildingintelligencegroup.com Building Intelligence

More information

Daylighting with Aerogel-Filled Multiwall Polycarbonate

Daylighting with Aerogel-Filled Multiwall Polycarbonate Daylighting with Aerogel-Filled Multiwall Polycarbonate AmeriLux International www.ameriluxinternational.com 1212 Enterprise Dr DePere, WI 54115 (888) 602-4441 f:(920) 336-9301 Provider Number:K408 Course

More information

CERAMIC FRIT SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

CERAMIC FRIT SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1 SPANDREL GLASS DATA SHEET / Quebec Version 2.1 Glass with MULTIVER SPANDREL GLASS DEFINITION A glass panel assembled with an opaque layer in position 2 or 4 of a sealed unit. Spandrel glass is generally

More information

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS Product Rating The timber product does not contain added urea-formaldehyde resins and contribute to achieve one LEED credit within IEQ Credit 4.4. The product contains 35% recycled materials and contribute

More information

Facade Design for Super High- Rise Building in Subtropic Region in China

Facade Design for Super High- Rise Building in Subtropic Region in China Facade Design for Super High- Rise Building in Subtropic Region in China Super high-rise building will always be iconic elements at any location. Accompanied by the growth of building technology and urbanization,

More information

SUSTAINABLE BUILDING DESIGN

SUSTAINABLE BUILDING DESIGN SUSTAINABLE BUILDING DESIGN LEED and HVAC How Trane can help. HVAC and LEED 2009 BUILDING DESIGN AND CONSTRUCTION (BD+C)... Building on its past success, the U.S. Green Building Council (USGBC), the nonprofi

More information

HELPING HVAC PROFESSIONALS TAKE THE LEED ACHIEVING LEED CERTIFICATION

HELPING HVAC PROFESSIONALS TAKE THE LEED ACHIEVING LEED CERTIFICATION HELPING HVAC PROFESSIONALS TAKE THE LEED ACHIEVING LEED CERTIFICATION Green proof of performance pays Sustainable design saves energy, opens doors and improves building status The rapidly growing segment

More information

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition

PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition PROPOSED SAN FRANCISCO GREEN BUILDING CODE AMENDMENTS 2016 Edition Chapter 1 GENERAL SECTION 101 GENERAL 101.1 Title. These regulations shall be known as the California San Francisco Green Building Standards

More information

Passive Solar Building Design Guidelines and Recognition Program

Passive Solar Building Design Guidelines and Recognition Program Passive Solar Building Design Guidelines and Recognition Program EXHIBIT B December 2006 Proposal Prepared by City of Santa Barbara Community Development Department Purpose of These Guidelines These guidelines

More information

Section Wood Grille Ceiling Panels

Section Wood Grille Ceiling Panels Section 095426 Wood Grille Ceiling Panels PART 1 GENERAL RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification sections

More information

Daubois Inc. BLOCMIX 20 MPa

Daubois Inc. BLOCMIX 20 MPa CONTRIBUTION LEED FICHE TECHNICAL TECHNIQUE DATA LEED SHEET Daubois Inc. Daubois Inc. manufactures and distributes specialized mortars and pre-mixed concrete. The company s two business divisions are the

More information

WMU Facility Life Cycle Design Guidelines Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16)

WMU Facility Life Cycle Design Guidelines Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16) Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16) Developed by Sustainable Design Committee: Christopher Caprara, Devon Miller, Carolyn Noack, Eleonora Philopoulos, Kelsey Pitschel,

More information

Green Building Guideline of Jordan

Green Building Guideline of Jordan Green Building Guideline of Jordan T. Awadallah 1*, S. Habet 1, A. Mahasneh 1, H. Adas 2 1 Royal Scintific Society, Amman, Jordan 2 National Energy Research Center, Amman, Jordan * Corresponding author.

More information

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH Pearl River Tower Guangzhou, China AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH Pearl River Tower The 71-story (309m) Pearl River Tower (PRT) redefines what is possible in sustainable

More information

LEED -Existing Buildings. Crescent Ridge Corporate Center I

LEED -Existing Buildings. Crescent Ridge Corporate Center I LEED -Existing Buildings Crescent Ridge Corporate Center I LEED Leadership in Energy and Environmental Design The U.S. Green Building Council is a coalition of leaders in the building industry promoting

More information

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world

SageGlass. SageGlass Product Guide. Dynamic glass for a changing world SageGlass Dynamic glass for a changing world SageGlass Product Guide Ultra-efficient SageGlass provides unmatched performance and proven reliability in commercial, institutional and residential buildings

More information

Projected actual points. Responsible for UNC -- Project name. Remarks

Projected actual points. Responsible for UNC -- Project name. Remarks UNC LEED Checklist Total points available Projected Responsible for UNC -- Project name Cost documentation Sustainable Sites Prerequisite- Erosion and Sediment control Prerequisite REQ Y All campus projects

More information

GENERAL REVELATION FOR SHIPPING CONTAINERS

GENERAL REVELATION FOR SHIPPING CONTAINERS GENERAL REVELATION FOR SHIPPING CONTAINERS Float Glass Land Carriage Package Stock- Loading Container Innovative Leading in Glass Innovative Leading in Glass GENERAL TERMS & CONDITIONS FOR SHIPPING CONTAINERS

More information

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by

More information

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic

More information

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL Guide Specifications 2012 Master Format Section 07 42 13.19 Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL 1.1 Work Included A. Pre-insulated metal panel

More information

BIRD FRIENDLY ACID-ETCHED GLASS

BIRD FRIENDLY ACID-ETCHED GLASS GUIDELINES FOR PRODUCT SELECTION AND ORDERING PRODUCT SELECTION CRITERIA Walker Textures full surface and AviProtek patterned acid-etched glass products provide bird collision deterrence properties in

More information

sky 700 MODULAR WALL SYSTEM

sky 700 MODULAR WALL SYSTEM sky 700 MODULAR WALL SYSTEM WHAT IS ESSENTIAL IS INVISIBLE Transparency and purity of lines. Silence and light. The modular walls of the Sky 700 Collection offer incomparable performance and utility, adding

More information

Green Building Guideline of Jordan

Green Building Guideline of Jordan Green Building Guideline of Jordan T. Awadallah 1*, S. Habet 1, A. Mahasneh 1, H. Adas 2 1 Royal Scientific Society, Amman, Jordan 2 National Energy Research Center, Amman, Jordan * Corresponding author.

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

LEED V4 FACT SHEET FOR STEEL PRODUCTS USED IN CONSTRUCTION APPLICATIONS

LEED V4 FACT SHEET FOR STEEL PRODUCTS USED IN CONSTRUCTION APPLICATIONS LEED V4 FACT SHEET FOR STEEL PRODUCTS USED IN CONSTRUCTION APPLICATIONS Designers and builders have long recognized steel for its strength, durability and functionality. An important aspect of steel s

More information

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm. 1 General This glazing specification outlines the general considerations for glazing as used in security glazing applications (ballistic, bomb blast and burglary resistance). 2 Materials Minimum requirements

More information

Smart. Easy. Profitable.

Smart. Easy. Profitable. Smart. Easy. Profitable. SageGlass dynamic glass for commercial, industrial and residential buildings Generate larger and more profitable contracts, differentiate yourself from competitors, and stay ahead

More information

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories. Permatherm Specification SECTION 07435 (CSI MasterFormat 1995) SECTION 07 42 43 (CSI MasterFormat 2004) SECTION 07 42 13.19 (CSI MasterFormat 2012) INSULATED METAL and FRP WALL PANELS Part 1: General General:

More information