1 GENERAL STOCK LIST Toll Free Sales Fax Cincinnati Cavett Ave. Cincinnati, The ALL-NEW 2015 DD APP is here. Scan the QR code with your smartphone... it s FREE!!

2 DISCOUNT DRAINAGE SUPPLIES POLYVINYL CHLORIDE DRAINAGE (PVC) 4 thru 24 SDR35 Retained Gasketed Sewer Pipe 13 Sections 4 thru 6 SDR35 Solvent Weld Sewer Pipe 10 Sections Solid and Perforated Form-A-Drain 6 and 8 x 12 3 thru # Crush Sewer and Drain 10 Sections Solid and Perforated All SDR35 meets ASTM D3034. All Sewer and Drain meets ASTM D2729. We carry a large selection of fittings for all PVC piping. Quantity and job pricing available. 2

3 Plastic Trends is now Royal Building Products which provides a comprehensive product line of high quality pipe and fitting solutions for a variety of industries. MUNICIPAL Largest Offering of Molded Fittings PLUMBING Wide Range of Triple Certified Products We have provided innovative, precisionengineered PVC products for over 45 years

4

5 SERVICE. SAVINGS. AVAILABILITY. SCHEDULE 40 PVC / DWV 1½ thru 6 Belled End Schedule 40 DWV 10 Sections 4 thru 12 Belled End Schedule 40 DWV 20 Sections 4 thru 6 Belled End Schedule 40 DWV 10 Sections Perforated All Schedule 40 meets ASTM D1785 and D2665. We carry a large selection of fittings for all sizes. Quantity and job pricing available. HIGH DENSITY POLYETHYLENE 2 thru 6 Flex Solid and Perforated 4 and 6 Flex Filter-Wrapped 8 thru 24 Flex 20 Sections 4 thru 60 Dual Wall 20 4 Flex Leach Pipe 3 thru 4 Triwall Solid and Perf All tubing meets or exceeds ASTM F405 and ASTM F 667. We carry a large selection of fittings. Quantity and job pricing is always available. 8 thru 36 dual wall can be cut in 5 increments. 5

6 DISCOUNT DRAINAGE SUPPLIES CORRUGATED STEEL CULVERT PIPE All steel pipe meets AASHTO M-36 Specifications Pipe can be cut to your specific needs for a small cutting charge Quantity and job pricing is always available ELECTRICAL CONDUIT 4 Direct Burial Conduit DB x 10 SCH40 U.L. Conduit 4 x 10 SCH40 U.L. Conduit 3 x 10 SCH40 U.L. Conduit 2 x 10 SCH40 U.L. Conduit 6 thru 48 Galvanized 16 gauge 20 Sections 12 thru 48 Aluminized 16 gauge 20 Sections 18 thru 48 Aluminized Ultra Flow 16 gauge 20 Sections 12 Slotted Steel Drain 16 gauge 20 Sections - 6 High Grate 12 Slotted Steel Drain 16 gauge 20 Sections - 2½ High Grate 6 thru 36 Steel End Sections Long sweep 90 Elbows, Caps and Couplings available. Quantity and job pricing available. WATERLINE COILS (POLY) ¾ x 100 CTS 200 PSI 1 x 100 CTS 200 PSI 1¼ x 100 CTS 200 PSI 1½ x 100 CTS 200 PSI 2 x 100 CTS 200 PSI ¾ x 500 CTS 200 PSI 1 x 500 CTS 200 PSI 1¼ x 500 CTS 200 PSI 1½ x 500 CTS 200 PSI 2 x 500 CTS 200 PSI Brass compression and flare couplings available for all sizes. 6

7

8 DISCOUNT DRAINAGE SUPPLIES WATERPROOFING Visqueen 4mil & 6mil Ameri-Block 8 x 50 Ameri-Block PLUS 8 x 50 Zoeller 1/3, ½ HP Sump Pumps Zoeller Battery Backup Pumps Blue Angel 1/3 HP Sump Pumps Blue Angel 1/3 HP Pumps w/ Backup Pit Bull / Pit Boss Backup Kit Hydromatic 1/3, ½ HP Sump Pumps 18 x 24 Sump Pit 18 x 30 Sump Pit 18 x 22 Radon Pits 18 x 30 Radon Pits Prime Resins PVC WATER PIPE 1½ SDR 21 CL200 Water Pipe 20 2 SDR 21 CL200 Water Pipe 20 3 SDR 21 CL200 Water Pipe 20 4 SDR 21 CL200 Water Pipe 20 6 DR18 C900 Water Pipe 20 8 DR18 C900 Water Pipe 20 SDR 21 is a 200 PSI Pressure Rated Gasketed PVC which meets ASTM D1784 and ASTM C900 DR18 is a 150 PSI pressure rated gasketed PVC which meets ASTM D

9 SERVICE. SAVINGS. AVAILABILITY. CONCRETE TRENCH DRAINS 4 x 39 Galvanized ADA Grates 6 x 39 D.I. Grates 8 x 39 D.I. Grates 12 x 39 D.I. Grates PLASTIC TRENCH DRAINS 1 x 10 Micro Channel White, Tan, and Gray Grates 3 x 6 Mini Channel Black, Green, and Gray Grates 3 x 39 Pro Channel Gray Grate 5 x 39 Pro Channel Gray Grate STEEL TRENCH DRAINS 6 x 4 Dura Slope Channel Gray and Cast Iron Grate Various Color Grates Available 6 Steel Drain, in 4, 5, and 6 Sections With: - Standard steel grate - Cast iron grate - Heavy duty plastic grate - Pedestrian grate 8 Steel Drain, in 4, 5, and 6 Sections With: - Standard steel grate - Cast iron grate 12 Steel Drain, in 4, 5, and 6 Sections With: - Standard steel grate - Cast iron grate Easy bolt together for longer runs. Slope can be poured into 8 and 12. 9

10

11 SERVICE. SAVINGS. AVAILABILITY. PLASTIC CATCH BASINS 6 Round Basin Black, Green, and Gray Grates 9 x 9 Square Basin Black, Green, and Gray Grates 12 x 12 Square Basin Black, Green, and Gray Grates 18 x 18 Square Basin Black, Green, and Gray Grates 24 x 24 Square Basin Black, Green, and Gray Grates 12 Round Poly Lock Basin 20 Round Poly Lock Basin Basins come with multiple outlets Outlet sizes are 3, 4, 6, 8, 10 and 12 Almost all types of pipe can be used 6 and 12 risers are available with basins. CONCRETE PRODUCTS 12 x 12 Basin 18 x 18 Basin 2 x 2 x 2 Basin 2 x 2 x 3 Basin 2 x 2 x 4 Basin 3 x 3 x 3 Basin 6 x 12 Risers 6 x 12 Risers 2 x 2 x 4 Risers 2 x 2 x 6 Risers 2 x 2 x 12 Risers 2 x 2 x 18 Risers 2 x 2 x 2 Risers 3 x 3 x 6 Risers 3 x 3 x 12 Risers 3 x 3 x 2 Risers Single Gutter Curb Inlets Double Gutter Curb Inlets Storm Manholes 12 thru 24 Reinforced Concrete Pipe HW-1 and HW4B Headwalls All cast iron casting are available in stock. M.H. Grade Rings 11

12

13

14 DISCOUNT DRAINAGE SUPPLIES FLEXIBLE RUBBER PIPE CONNECTIONS 2 thru 24 Plastic / CI to Plastic / CI 4 thru 24 Clay to Plastic / CI 4 thru 24 Concrete to Plastic / Cl 4 thru 12 Ductile to Plastic / Cl 4 Flexible Tee 4 Flexible 90 Elbow 4 x 6 Quick Caps Quantity pricing is available. GEOTEXTILES, FENCE, MATTING 2 x 100 Silt Fence 3 x 100 Orange Silt Fence Orange Safety Fence Woven Geotextile 12½ x 432 Non-Woven Geotextile 12½ x 360 Geogrid BX114GG 13.1 x 246 High Flow Dandy Bags Straw Matting Straw Wattles 14

15 SERVICE. SAVINGS. AVAILABILITY. MISCELLANEOUS q PVC Glue q PVC Primer q Pipe Joint Lube - Gel or Spray q Expanding Foam q Sand Mix q Concrete Mix q Mortar Mix q Blacktop Patch q Waterplug q Marking Paints q Detectable Tapes q Caution Tapes q Duct Tape q Tile Tapes q Window Wells - 12, 18, 24, 30 and 36 q Plastic Septic Tank - 300, 500, 1000 and 1500 Gallon q EZ Flow q Infiltrator Chambers q Anti-Seep Collars q 1/2 Rebar - 10 and 20 Lengths q Animal Guards - 4, 6, 8, 12, 15 and 18 q Equipment Locks q 5 x 150 Wire Rolls - 10 Gauge q Pond Overflow Structures q PVC Saddle - 6 thru 18 Tee or Y q Poly Saddles and Inserta Fittings q Plastic and Cast Iron Grates q Square, Round or Rectangle Grates 15

16 DISCOUNT DRAINAGE SUPPLIES HAND TOOLS q Round-Tip Shovel q Square-Tip Shovel q 4 Trench Shovel q 6 Trench Shovel q Post Hole Digger q Proves q Spud Bar q Bow Rake q Landscape Rake q Concrete Rake q 6 Trench Tamper q 10 Trench Tamper q Surveyor s Tape q 12 Cut Off Saw Blade q PVC Saws q Cable Saw q Pipe Wrenches q PVC Cutters q Gloves 16

17

18

19 SERVICE. SAVINGS. AVAILABILITY. SEPTIC SYSTEM SUPPLIES Plastic Septic Tanks Flexible Leach Pipe Concrete Distribution Boxes EZ Flow Septic Line Bull Run Valves Leach Field Chambers Rigid Leach Pipe Concrete Septic Tanks 8 Graveless 20 WATERPROOFING 1/3 HP Zoeller M53 Sump Pumps 1/3 HP Zoeller M72 Sump Pumps ½ HP Zoeller M98 Sump Pumps 18 x 24 Sump Pits 18 x 30 Sump Pits Basement Sentry Backup Pump Zoeller Wet Battery Zoeller Ameri-Block 8 x 150 Ameri-Block Plus 8 x 150 Blue Angel Pump System w/ Backup Hydromatic Pump 1/3 Horse 19

20 DISCOUNT DRAINAGE SUPPLIES REBAR AND EXPANSION JOINT #3 Rebar #4 Rebar 5 x 150 Wire Mesh 10Ga 2 Bar Rebar Chair Plastic 2 Bar Rebar Stake 2 Bar Rebar Chair 3 Bar Rebar Chair Tie Wire 3½ # Coil Tie Wire 6½ In Looped Tie Wire 9 In Looped Expansion Joint Expansion Joint Expansion Joint Expansion Joint Expansion Joint 3 x 5 ¼ Fiber 3 x 5 ½ Fiber 4 x 5 ¼ Fiber 4 x 5 ½ Fiber 6 x 5 ½ Fiber 20

21

22 PUT OUR DEDICATED STAFF WITH OVER 59 YEARS OF EXPERIENCE TO WORK FOR YOU! We Are Proud To Be A Locally-Owned OHIO COMPANY! The Discount Drainage family lives and works in the same communities where you live and work. That means the salaries and tax dollars we pay get reinvested locally. All our products are made in the - many are from manufacturers. Heritage Pipe To be the customer s first choice for high value products, by providing unmatched quality, delivery, and value based on sustainable excellence in strategy, people and processes.

23 SERVICE. SAVINGS. AVAILABILITY. LIST OF VENDORS Vendor AgriDrain Place of Manufacture Vendor Marflex Place of Manufacture Ameri-Block (North American Specialty Products) A Y MacDonald ACO ADS/Hancor Blue Angel Pumps Form A Drain Charter Plastics Contech Construction Products Diamond Plastics East Jordan Iron Works Edwards Steel Encore Precast Fernco Form-A-Drain (North American Specialty Products) Marshall Stamping Migchelbrink Precast Multi Fittings NDS National Pipe Normandy Products North American Pipe Norwesco Oil Creek Plastics Perfection Pipe Conx Pipelife Jet Stream Plastic Trends Polylok Silverline Plastics Heritage Plastics Simmons Manufacturing Hydromatic Pumps Smart Ditch Infiltrator Tolloti Invisible Structures Tuftite Lasco Ultratech Legend Valve Uniontown Septic Lenox Tools JC Whitlam Logan Clay Zoeller Pumps All of our products are proudly manufactured locally in or the United States 23

24 TIME IS MONEY... LET US SAVE YOU BOTH! Discount Drainage Supplies 200 Cavett Ave. Cincinnati, CHANGE SERVICE REQUESTED FREE SAME-DAY DELIVERY for orders over $500

GENERAL STOCK LIST. Toll Free Sales Fax Cavett Ave., Cincinnati, Ohio 45215

GENERAL STOCK LIST. Toll Free Sales Fax Cavett Ave., Cincinnati, Ohio 45215 GENERAL STOCK LIST Toll Free 1-866-284-8897 Sales Fax 513-563-8929 WWW.DISCOUNTDRAINAGE.COM 200 Cavett Ave., Cincinnati, 45215 DISCOUNT DRAINAGE SUPPLIES POLYVINYL CHLORIDE DRAINAGE (PVC) 4 thru 24 SDR35

More information

GENERAL STOCK LIST. Toll Free Sales Fax South Arlington Road, Akron, OH 44319

GENERAL STOCK LIST. Toll Free Sales Fax South Arlington Road, Akron, OH 44319 GENERAL STOCK LIST Toll Free 1-800-407-0011 Sales Fax 330-644-7429 WWW.DISCOUNTDRAINAGE.COM 2600 South Arlington Road, Akron, OH 44319 DISCOUNT DRAINAGE SUPPLIES POLYVINYL CHLORIDE DRAINAGE (PVC) 4 thru

More information

LIST STOCK GENERAL Toll Free. Sales Fax. Columbus

LIST STOCK GENERAL Toll Free. Sales Fax. Columbus www.discountdrainage.com GENERAL STOCK LIST Toll Free 1-877-274-1127 Sales Fax 614-882-1362 Columbus 614-882-3402 4675 Westerville Rd. Columbus, 43231 The ALL-NEW 2015 DD APP is here. Scan the QR code

More information

Drainage and Erosion Control

Drainage and Erosion Control Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion

More information

POLYLOK / ZABEL PRODUCT BROCHURE v.3

POLYLOK / ZABEL PRODUCT BROCHURE v.3 POLYLOK / ZABEL PRODUCT BROCHURE v.3 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs

More information

PART 5 WATER SYSTEMS

PART 5 WATER SYSTEMS PART 5 WATER SYSTEMS Abbreviations and Symbols Plan 501 Abbreviations and symbols for water... 205 Concrete Boxes and Hardware 502 27" Frame and cover... 207 503 38" Frame and cover... 209 505 Concrete

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems SECTION 02607-1 1.0 GENERAL 1.1 SCOPE: A. This section covers the work necessary for the construction of sanitary and storm system manholes, catch basins, and miscellaneous concrete structures complete.

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02630 - STORM DRAINAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Storm Drainage

Storm Drainage University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards 4-23-2015 334100 - Storm Drainage Sandra Hickey

More information

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation SECTION 33 40 00 STORM DRAINAGE UTILITIES 1. PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 00: Excavation and Fill B. Section 32 00 01: Site Restoration and Rehabilitation C. Special Conditions for

More information

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm) Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

TYPE "A" CATCH BASIN

TYPE A CATCH BASIN 27" 1.67' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3250-BV OR APPROVED EQUAL. "INFI SHIELD" SEAL OR APPROVED EQUAL RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR). PLASTER OUTSIDE,

More information

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS Storm Sewer System: 1. Detention/retention of stormwater runoff shall be provided in accordance with the requirements of the DuPage County Countywide Stormwater

More information

***************************************************************************************************************

*************************************************************************************************************** 02720 STORM DRAINAGE SYSTEM *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 33 40 00. ***************************************************************************************************************

More information

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS DRAINAGE SOLUTIONS SINCE 1908 BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS PROTECT FOUNDATIONS IMPROVE HIGHWAY

More information

Summary of the 2011 Changes

Summary of the 2011 Changes The following is a list of amendments to the Residential Site Improvement s, N.J.A.C. 5:21, adopted in 2011. The Notice of Adoption of these changes appeared in the New Jersey Register on May 16, 2011.

More information

Storm Drainage Structures

Storm Drainage Structures Storm Drainage Structures Tomorrow s Drainage System Today A DIVISION OF ADVANCED DRAINAGE SYSTEMS, INC. ADVANCED DRAINAGE SYSTEMS, INC. The Preferred Solution for Storm Drainage Applications. About Nyloplast-ADS

More information

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION.

CHECK THE LOWER RIGHT CORNER OF EACH DETAIL FOR THE LATEST REVISION. Standard Drawings Index NOTE: The specifications for materials and workmanship shall conform to the latest edition or the "Standard Specifications for Public Works Construction" published by the North

More information

YOUR SPLASH PAD RESOURCE

YOUR SPLASH PAD RESOURCE 1 Index Permits & Inspections Material List Warnings Splash Pad Types Pre-Site Grading Plumbing Schematic Pressure Testing Concrete Preparation and Pour Housing/Nozzle Installation Above Ground Water Feature

More information

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE 3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR).

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 33 40 00 Storm Drainage 1. Introduction A. Duke University is divided into the main areas of the Medical Center, West Campus, Central Campus, and East Campus. The University also includes the Washington

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

CITY OF EDMOND STANDARD SPECIFICATIONS FOR CONSTRUCTION Edition

CITY OF EDMOND STANDARD SPECIFICATIONS FOR CONSTRUCTION Edition CITY OF EDMOND STANDARD SPECIFICATIONS FOR CONSTRUCTION PURPOSE, INTENT AND INTERPRETATION OF SPECIFICATIONS The purpose of these Specifications is to establish, where applicable, minimum acceptable standards

More information

Inlets & Catch Basins

Inlets & Catch Basins A Delivering Reliability Inlets & Catch Basins Water-Conveyance & Drainage A Environmentally Responsible Oldcastle Precast to the Rescue All of our products are produced in a controlled environment helping

More information

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS COMPLETE THROUGH REVISION #18 April 2009 CITY STANDARD DETAILS REVISIONS Revision No. Revision Date Effective Date 2 August

More information

Facility Sanitary Sewers

Facility Sanitary Sewers University of New Hampshire University of New Hampshire Scholars' Repository Division 22 Plumbing Chapter 5 Technical Construction and Renovation Standards 4-23-2015 221313 - Facility Sanitary Sewers Sandra

More information

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS PART 3 - STANDARDS FOR SEWERAGE FACILITIES 3.3 - DESIGN OF STORM SEWERS 3.301 Design of Storm Sewers A. General Information B. Investigations and Surveys C. Special Projects 3.302 Design Criteria for Storm

More information

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm Sewers B. Abandonment of Storm Sewers 1.02 DESCRIPTION OF WORK A. Construct storm sewers. B. Abandon storm sewers. 1.03 SUBMITTALS Comply with

More information

SECTION STORM DRAIN

SECTION STORM DRAIN PART 1 - GENERAL 1-01 SECTION INCLUDED A. Furnishing and installing storm drainage facilities, including pipe, cleanout, manhole structures and inlet structures. 1-02 RELATED SECTIONS A. Division 00 Contract

More information

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN

More information

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.0 Standard Specifications GWINNETT COUNTY STORM SEWER PIPE STANDARDS 1.1 Unless otherwise specifically set forth herein or in the Gwinnett County Standard Drawings, all of the materials, methods of the

More information

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS The following pages are an index of standards and specifications associated with Lane products. For quick reference purposes, Lane products are shown below

More information

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI GENERAL: The scope of this document is to provide instruction for the installation of concrete electric manholes. DESIGN GUIDELINES: 1. Materials for Manhole 1.1. Cast-in-Place or Pre-Cast concrete may

More information

Standard Specifications for Road and Bridge Construction. Adopted January 1, 2012

Standard Specifications for Road and Bridge Construction. Adopted January 1, 2012 Standard Specifications for Road and Bridge Construction Adopted January 1, 2012 Pipe Culverts Art. 542.02 SECTION 542. PIPE CULVERTS 542.01 Description. This work shall consist of furnishing and installing

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION FOUNDATION DRAINAGE

SECTION FOUNDATION DRAINAGE SECTION 33 41 13 SPEC WRITER NOTES: Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

The Road Authority ADS Nyloplast Stormwater Drainage System http://www.roadauthority.com/database/product.asp?prod=4241 28/04/2010 ADS Nyloplast Stormwater Drainage System Engineered PVC surface drainage

More information

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS UTAH COUNTY HEALTH DEPARTMENT Div. of Environmental Health 151 South University Avenue, Provo 84601 (801) 851-7525 FAX 851-7521 GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS This is intended to

More information

HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle

HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle HydraPressed Slabs Yorkstone Tan Wherefunctionmeetsstyle Texada This series is named after the rugged and beautiful Gulf Islands of the Pacific Northwest. Texada HydraPressed Slabs have a light shot-blast

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL: N 1133521.33 E 1689742.43 STA: 10+53.07 INSTALL: 2-10" 90 BENDS CONNECT TO MIDDLEBUSH HALL INTERIOR PLANT PLUMBING MIDDLEBUSH HALL HW1 HWS HWR 10+00 FREDRICK APARTMENTS FINE ARTS INSTALL 422 LF 10" HWS

More information

SERVICE LINES, METERS AND APPURTENANCES

SERVICE LINES, METERS AND APPURTENANCES AUGUST02 SECTION 02646 SERVICE LINES, METERS AND APPURTENANCES PART 1 - GENERAL 1.1 DESCRIPTION A. This section concerns materials and installation of corporation stops, curb stops, service lines, meters,

More information

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Underground Exhaust System

Underground Exhaust System Operation and Maintenance Manual Underground Exhaust MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 Underground Duct Construction Standards 1. Dig trench depth to allow for minimum distance from

More information

SEPTIC TANK CONSTRUCTION GUIDELINES

SEPTIC TANK CONSTRUCTION GUIDELINES SEPTIC TANK CONSTRUCTION GUIDELINES Septic tank for this airport will be designed/ built by the general contractor of the building facilities. At the time of the project design, availability of a septic

More information

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION UTILITY MANHOLES AND STRUCTURES SECTION 33 05 14 UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Precast reinforced concrete manholes and structures with tongue-and-groove joints with masonry transition

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation Gravity Grease Technical Data Submittal Special Precautions Specifications Installation 75" 81" (205.7 (94.0 cm) 19½" 20" (50.8 (49.5 cm) 21½" 20" (50.8 (54.6 cm) 76½" (194.3 cm) 56½" 57" (144.8 (143.5

More information

2018 Product Catalog. Your knowledgeable and trusted partner for the best in water management solutions. Commercial Stormwater Management

2018 Product Catalog. Your knowledgeable and trusted partner for the best in water management solutions. Commercial Stormwater Management Your knowledgeable and trusted partner for the best in water management solutions 208 Catalog Commercial Stormwater Management Residential Stormwater Management Professional Irrigation Flow Management

More information

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. SECTION 33 05 13 MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems. B. Related Sections: 1. Section 03 20 00 - Concrete

More information

STORM UTILITY WATER DRAINS

STORM UTILITY WATER DRAINS 1. Product Name ACO Drainª K100S General-Purpose Trench Drain ACO Drainª S100K Heavy Duty Trench Drain ACO Drainª S300K Heavy Duty Trench Drain ACO Drainª FG100 High Capacity Trench Drain ACO Drainª FG200

More information

ProSeal Flex Couplings

ProSeal Flex Couplings ProSeal Flex Couplings Stainless Steel Shielded Transition Couplings designed for resistance to shear forces as well as corrosion. Pasco s ProSeal Flex Couplings allow the plumber to make a wide variety

More information

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including

More information

All Regional Engineers. Omer M. Osman, P.E. Special Provision for LRFD Pipe Culvert Burial Tables. July 25, 2014

All Regional Engineers. Omer M. Osman, P.E. Special Provision for LRFD Pipe Culvert Burial Tables. July 25, 2014 All Regional Engineers Omer M. Osman, P.E. Special Provision for LRFD Pipe Culvert Burial Tables July 25, 2014 This special provision was developed by the Bureau of Bridges and Structures as a result of

More information

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION SPECIFICATION FOR PIPE CULVERT CONSTRUCTION 1. SCOPE Pipe culverts shall be constructed in accordance with this specification and in conformity with the lines, levels and cross-sections shown on the drawings.

More information

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS. Product Guide

THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS. Product Guide THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS Product Guide Table of Contents Page Minimum Angle Chart 1 Inline Drains 2 Drain Basins 8 Curb Inlet Structures 14 Road & Highway Structures 17 Riser

More information

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ONE PIPE LENGTH MAX (REFER TO 1/4/FT SLOPE (MIN) 5'-0 (MIN) OR 4 LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4x6 REFER TO TYPICAL EXCAVATION, VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 37" (94.0 cm) 10½" (26.7 (27 cm) 28½" (72.4 cm) (46.7 (45.7 cm) 28" (71.1 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

Appendix 4. Bills of Quantities

Appendix 4. Bills of Quantities Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic

More information

2015 / 2016 PRODUCT CATALOG. ndspro.com

2015 / 2016 PRODUCT CATALOG. ndspro.com 205 / 206 PRODUCT CATALOG ndspro.com We put water in its place From your backyard patio to the neighborhood aquatic center, from the factory floor to a professional sports facility, NDS offers the right

More information

SECTION STORM UTILITY DRAINAGE PIPING

SECTION STORM UTILITY DRAINAGE PIPING SECTION 33 41 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Special Provision No. 405F03 March 2005

Special Provision No. 405F03 March 2005 PIPE SUBDRAINS - Item No. VIDEO CAMERA INSPECTION Item No. Special Provision No. 405F03 March 2005 OPSS 405, February 1990, Construction Specification for Pipe Subdrains is deleted in its entirety and

More information

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction. General: 1. Construct utilities in accordance to TWA approved plans and shop drawings. Any deviation from the approved plans shall be approved by the DEVELOPER S ENGINEER and TWA 2. A preconstruction meeting

More information

Drainage Products Your Complete Source for all Drainage Items Corrugated Pipe (Solid and Perforated) Rain Bird Drainage Grates, Basins, Pop-up Valves and Fittings Corrugated Pipe Fittings FloWell Kits,

More information

STATE UNIVERPROGRAM DIRECTIVES

STATE UNIVERPROGRAM DIRECTIVES DIRECTIVE 15H-10 PIPING TYPES AND MATERIALS Issue date: September 2017 Steam & Condensate Piping Service & Location Pipe Size Pipe Material & Weight Joint Type Fitting Material Insulation Material Low

More information

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1 DIVISION 3: SEWER 3.1 DESIGN CRITERIA A. APPLICABILITY 1. These Design Standards shall govern all construction and upgrading of public sanitary sewer facilities in the City of Dundee and applicable work

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-33 46 13 (April 2008) -------------------------- Preparing Activity: USACE Superseding UFGS-33 46 13 (July 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are

More information

POLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES

POLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES 2018 www.precon.ca 2 2017 PROJECTS TABLE OF CONTENTS 3 2 PROJECTS 11 POLYETHYLENE LINED PRODUCTS 3 TABLE OF CONTENTS 12 IMPACT BAFFLES 4 CATCH BASINS 13 INLET/TURNOUTS 5 MANHOLE MATERIALS 14 FLARED END

More information

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated. ZGF Partnership Page 1 of 7 SECTION 33 46 00 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes subdrainage systems for foundations and underslab areas. 1.2 SUBMITTALS A. Product Data: For each type

More information

Storm Drainage Systems

Storm Drainage Systems Storm Drainage Systems A. Description This work shall consist of furnishing, constructing and/or reconstructing catch basins, manholes; with frames, grates, or manhole covers; as shown on the plans. This

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES January 18, 2013 811.01 Conduit Description 811.02 Conduit Materials 811.03 Conduit Definitions

More information

Transportation, Engineering and Development Business Group Standard Construction Plan Notes for Development Projects January 2013

Transportation, Engineering and Development Business Group Standard Construction Plan Notes for Development Projects January 2013 Transportation, Engineering and Development Business Group Standard Construction Plan Notes for Development Projects January 0 The City of Naperville Transportation, Engineering and Development (TED) Business

More information

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed

More information

DIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION

DIVISION 32 EXTERIOR IMPROVEMENTS IRRIGATION 32 80 00 PART 1 - GENERAL 1.01 DESIGN REQUIREMENTS A. Design shall be square or triangular spacing and head to head coverage. B. Electrical Design: Consultant is responsible for informing the Electrical

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT SECTION 322 - STORM DRAINAGE AND STORMWATER MANAGEMENT 322.01 DESCRIPTION Work includes all labor, material and equipment to construct storm drain systems and stormwater management facilities, including

More information

GB-75. Submittal Special Precautions Specifications Installation Application Specific Details

GB-75. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 38½" 38.5" (97.8 cm) 12½" (31.7 cm) 26" (66.0 cm) 46" 33½" 32" (851 (81.3 mm) cm) SUBMITTAL STANDARD: 4" plain end

More information

ENGINEERING DESIGN & IMPROVEMENT STANDARDS

ENGINEERING DESIGN & IMPROVEMENT STANDARDS ENGINEERING DESIGN & IMPROVEMENT STANDARDS 2016 Prepared by: Engineering Division For latest edition of these Improvement Standards, refer to City of Visalia website at: www.visalia.city/engineeringdocuments

More information

Spears Low VOC Solvent Cements, Primers & Accessories

Spears Low VOC Solvent Cements, Primers & Accessories SOLVENT CEMENT & ACCESSORIES Spears Low VOC Solvent Cements, Primers & Accessories Low VOC for LEED E Credit Environmentally friendly. LEED Compliant (Leadership in Energy and Environmental Design). Credit

More information

1. B16.1 Cast Iron Pipe Flanges and Flanged Fittings, Class C 111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings

1. B16.1 Cast Iron Pipe Flanges and Flanged Fittings, Class C 111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings SECTION 33 34 00 SANITARY FORCE MAIN PART 1 GENERAL 1.1 SCOPE OF WORK A. This section specifies the requirements for furnishing and installing sanitary force main and appurtenances. The pipe shall be of

More information

Construction Inspection Checklists

Construction Inspection Checklists III. Construction Inspection Checklists 33 Bioretention - Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: Construction Sequence Satisfactory / Unsatisfactory Comments

More information

PITTSBURGH TECHNOLOGY CENTER PUBLIC IMPROVEMENTS SITE PREPARATION CONTRACT NO. 11 BID TABULATION BID OPENING DATE: MARCH 11, 2008

PITTSBURGH TECHNOLOGY CENTER PUBLIC IMPROVEMENTS SITE PREPARATION CONTRACT NO. 11 BID TABULATION BID OPENING DATE: MARCH 11, 2008 BT-1 of 7 Clearing and Grubbing L.S. $50,000.00 $50,000.00 $5,335.00 $5,335.00 $14,560.00 $14,560.00 $20,000.00 $20,000.00 $10,600.00 $10,600.00 Class 1 Excavation 4300 C.Y. $20.00 $86,000.00 $15.00 $64,500.00

More information

STORM AND SURFACE WATER 4-1 GENERAL...4-1

STORM AND SURFACE WATER 4-1 GENERAL...4-1 SECTION 4 STORM AND SURFACE WATER SECTION DESCRIPTION PAGE 4-1 GENERAL...4-1 4-2 STORM DRAINAGE CONVEYANCE SYSTEM DESIGN CRITERIA...4-1 4-2.1 Overview...4-1 4-2.2 Design Flow and Route Requirements...4-2

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CHAPTER 6. Sanitary Sewer

CHAPTER 6. Sanitary Sewer CHAPTER 6 Sanitary Sewer A. Introduction All proposed developments, subdivisions, and buildings must have a properly designed and constructed sanitary sewer collection system. The system shall provide

More information

GB-75. Submittal Specifications Installation Application Specific Details

GB-75. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 38½" 51½" (1,308 (978 mm) 13½" 12½" (343 (318 mm) 38" 26" (660 (965 mm) 68" 46" (1,168 (1,727 mm) 33½"

More information

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS 701-1 DESCRIPTION 701-1.1 This item shall consist of the construction of pipe culverts, and storm drains, removal of existing storm pipes, connections to existing

More information

Welcome: What is U-Drain? Drain Materials. Flow

Welcome: What is U-Drain? Drain Materials. Flow Welcome: Thank you for looking into the U-Drain floor drain system. This paper will explore the functional features of the U-Drain and why it is superior to other grated systems in the marketplace. We

More information

PRECAST RECTANGULAR CHAMBERS

PRECAST RECTANGULAR CHAMBERS STANDARD MODELS GENERAL ROUGH SKETCH Available for: Sewer manhole, valve chamber, trouser manhole, and pumping station. Ø60-Ø762 ADJUSTMENT RING 7-00-2-0 20-2 30-60 RING 200-30 60-60 000-220 9ø 6 FLAT

More information

Request for Bids Sewer Department City of Portsmouth, New Hampshire Sewer Inventory Bid #48-15

Request for Bids Sewer Department City of Portsmouth, New Hampshire Sewer Inventory Bid #48-15 Bid #48-15 Request for Bids Sewer Department City of Portsmouth, New Hampshire Sewer Inventory Bid #48-15 City of Portsmouth Public Works Department Sewer Inventory INVITATION TO BID Sealed bid proposals,

More information

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of

More information

GUIDANCE MEMO NO : GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES

GUIDANCE MEMO NO : GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES State of California Memorandum Department of Health Services Date: April 4, 2003 To: From: Subject: Regional and District Engineers David P. Spath, Ph.D., Chief (Original signed by Dave) Drinking Water

More information

ACO Construction & Building Products

ACO Construction & Building Products ACO Construction & Building Products Sur face Drainage and Building Elements ACO SPORT System 4000 Product Brochure Open Trench Drain System for Tracks, Sports Fields and Recreational Areas ACO SPORT System

More information