POLYLOK / ZABEL PRODUCT BROCHURE v.3

Size: px
Start display at page:

Download "POLYLOK / ZABEL PRODUCT BROCHURE v.3"

Transcription

1 POLYLOK / ZABEL PRODUCT BROCHURE v.3

2 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs Pyramid Wire Clips 12 x12 Square for Catch Basins & D-Boxes 12 x12 Atrium 12 x12 Square D-Box

3 ONSITE WASTEWATER PRODUCTS EFFLUENT FILTERS PL-68 /Tee PL-122 PL-250 PL-525 PL-625 Effluent /Grease Trap Best GF10 Zabel A1800 Series Zabel A100/300/600 8 Series Zabel A100/300/ Series FILTER & TANK ACCESSORIES 3, 4 & 6 Extend & Lok Smart Alarm & Switch Handles Zabel Versa-Tee Polylok Baffle Gas Deflectors RISER & PIPE COVERS HD 15 HD 18 HD HD Flat 24 HD 30 HD SEPTIC TANK RISERS & RISER PANS 12 x6 x2 x3 / Pan x6 x12 Pan 24 x2 24 x3 / Pan 24 x6 24 x12 RISER & PIPE ADAPTER RINGS 12 Polylok & Pipe Adapter Ring & 24 Polylok 24 Adapter Ring Pipe Ring 18 Corrugated Adapter Ring 24 Corrugated Adapter Ring -to- 24 -to-

4 ONSITE WASTEWATER PRODUCTS SAFETY PRODUCTS 12, & 24 Polylok Safety Screen 24 Universal Safety Screen & 24 Lid-Lok Safety Device 24 Dual Safety & 24 Pan DISTRIBUTION BOXES ODOR CONTROL & VENTS 12 x12 Square Distribution Box 12 Round Distribution Box (6, 7 & 8 Hole) Round Distribution Box 1.5, 2, 3, 4 & 6 Poly-Air Activated Carbon Roof Vent 18,, 24 & 30 Activated Carbon s 3 Air Vent & 4 Vent Guard WASTEWATER ACCESSORIES 4 Equalizer Roto-Flows.75-1 & Orifice Diffusers 1 /1.25 /1.5 & 1 /1.5 /2 Hydro Shields 4 Flow Controller Dipper Assembly for concrete forms SUBMERSIBLE PUMPS & AIR PUMPS ALARMS BASINS Sump Pumps, Effluent Pumps, Sewage Pumps & Grinder Pumps Air Pumps & Enclosures Tank Alarms, Floats, Control Panels & Junction Boxes Custom Basins Pre-Packaged Pump Basins Low Profile Basins, w/ & SPECIALTY FILTRATION ENZYMES & BACTERIA DECORATIVE STONES INSULATION Step System High Pressure UV Unit Prep & Clean Poly-Cleanse Many sizes and shapes available & 24 Insulation for Polylok s

5 LANDSCAPE DRAINAGE PRODUCTS HEAVY DUTY TRENCH DRAINS Note: 90 Corner, Tee, Open End Cap & Closed End Cap are available in Tan, Green, Grey & Black) 90 Corner & Tee also available in Ductile Heavy Duty Trench Drain (Tan, Green, Grey, Black & Ductile ) 90 Corner Tee Open End Cap Closed End Cap Corrugated Adapters DRAINGE BOXES & CATCH BASINS 9 & 12 Plastic 9 & 12 Plastic 9 & 12 Cast Iron 12 Round Drainage Box (6, 7 & 8 Hole) Round Drainage Box 12 x 12 Square for catch basins & D-Boxes 12 x 12 Atrium 9 x 9 & 12 x 12 Catch Basins Plastic & Metal s Available GRATES & FLOW GATES Optional elbow 3, 4, 6, 8 & 10 Pipe s 12 HD Metal 15 HD 18 HD Metal 24 HD 4 Atrium Flow Gate PIPE SEALS & GROMMETS 1.5, 2, D-Box Seal 6 D-Box Seal Poly I Pipe Seal Poly II Pipe Seal Baffle/ Ready Seal Universal Ready Adapter Grommets BOOT SEALS & MANDRELS 2 Open End 2 Closed End Poly III Closed End Poly IV Open End Poly IV Closed End Poly VI Closed End Mandrels & Magnetic Mandrels

6 PRECAST CONCRETE PRODUCTS REBAR SPACERS Push-On Wheel Chairs Locking Wheel Chairs Viper-Lok Rebar Spacer Stackable Chairs Round Base Chairs X-Chairs Mesh Chairs Pyramid Wire Clips Beam Bolster Uppers Stacking Slab Bolsters Rebar End Spacer CONCRETE ACCESSORIES Rebar Safety Cap Rebar Scratch Cap Inspection Tags Custom & Standard Signs Handles & Receivers Butyl Sealant Cable Lift Loops Threaded Zinc Inserts Threaded Insert Locators Mold Fastening Nails Equals & Unequals Pocket Formers Lift Hole Plugs Corner Guards Bearing Pads/ Concrete Panel Spacers Shims Forms Clamps, Hinges & Posts Poly-Lube Form Hammer OUR COMMITMENT TO QUALITY, INNOVATION & CUSTOMER SERVICE Polylok, Inc. is the world leader in providing products to the precast, drainage and onsite wastewater industries. We have a reputation for delivering cost conscious, high quality, innovative products. Polylok has been in business since 1984 and holds over 75 patents on our products. Our products are manufactured in the United States and shipped worldwide. We pledge to always focus on quality, innovation and customer service. Since our inception, we have been driven to design, build and improve upon products for the precast, drainage and onsite wastewater industries. We have a proven track record that shows our commitment for over 30 years. Polylok continues to introduce innovative products to the market place, year after year. MEMBER MEMBER MEMBER

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115 SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPSE3A 1/3 44 0 1½ NPT EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPE4A-1 PL-CPE5A-1 PL-CPEH5A1 PL-CPSTEP51A PL-CPSTEP10A

More information

LANDSCAPE DRAINAGE PRODUCTS

LANDSCAPE DRAINAGE PRODUCTS 3 Pipe Grate PDB-3G-BK PDB-3G-GN 4 Pipe Grate PDB-4G-BK PDB-4G-GN 4 Atrium Grate PAG-4-BK PAG-4-GN 6 Pipe Grate PDB-6G-BK PDB-6G-GN 8 Pipe Grate PDB-8G-BK PDB-8G-GN 10 Pipe Grate PDB-10G-BK PDB-10G-GN

More information

CONCRETE ACCESSORIES. Plastic. Spacers SPACERS

CONCRETE ACCESSORIES. Plastic. Spacers SPACERS ACCESSORIES Plastic Spacers 60 REBAR LOCKING WHEEL The CONAC Wheel Chairs are the strongest wheel chairs on the market. The patented locking system will not allow the wheel to rotate around the rebar or

More information

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 13 00 _SANITARY SEWER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer piping buried 2. Sanitary

More information

Section 10 Design Criteria: Components

Section 10 Design Criteria: Components 1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water

More information

VSS S U B M E R S I B L E S E W A G E P U M P S

VSS S U B M E R S I B L E S E W A G E P U M P S 7 2 9 8 / 2 3 HP % % 64% 7 5 HP HP 5 HP % % C u r v e P a g e V S S - 4 5 R P M M O D E L : V S S - 4 E I M P E L L E R : V S A - 4 C - 2-5 A l s o a p p l i e s t o V S S - 5 E & V S S - 6 E 7 7 65 55

More information

Below ground System of pipework required to carry waste fluids from building to disposal site.

Below ground System of pipework required to carry waste fluids from building to disposal site. 1 Below ground System of pipework required to carry waste fluids from building to disposal site. Disposal site County Council sewage treatment facility. Septic tank system or alternative systems 2 1. Layout

More information

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING Flows to 200 GPM. TDH to 95 Feet at 1750 RPM Free Standing or Guide Rail Design. Available in Standard Submersible or Explosion Proof Design. Provided with 25 feet of submersible motor power cable. Cast

More information

PowerDrain Section. Technical Handbook and Product Catalog. Heavy duty trench drainage

PowerDrain Section. Technical Handbook and Product Catalog. Heavy duty trench drainage Technical Handbook and Product Catalog Surface Drainage 6 Surface drainage options 8 Product selection 10 Trench drain hydraulics 16 Loadings 22 Material data 24 End user requirements Standard Products

More information

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS UTAH COUNTY HEALTH DEPARTMENT Div. of Environmental Health 151 South University Avenue, Provo 84601 (801) 851-7525 FAX 851-7521 GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS This is intended to

More information

Complete Modern Drainage System

Complete Modern Drainage System Complete Modern Drainage System Ideal for collection of high surfacewater flows in large domestic & light commercial applications Made in Australia from tough, durable and light-weight UV-stabilised recycled

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 14 00 _STORM WATER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Storm water piping 2. Roof drains. 3. Area

More information

Art Mould Plastics "SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966"

Art Mould Plastics SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966 Art Mould Plastics "SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966" 1 of 10 Table of Contents Individual Support Chairs Linden Chairs. 3 Sand Plates 3 X-Chairs.. 4 Rod Spacers.. 4 Type-A. 5 Sand

More information

Unit Rate. Subtotal in SDG. Site Clearing Preliminary Works. 1.0 Job. Excavation & Earth Works. Stone Masonry Works in foundation 100 M.

Unit Rate. Subtotal in SDG. Site Clearing Preliminary Works. 1.0 Job. Excavation & Earth Works. Stone Masonry Works in foundation 100 M. Bill of Quantities Nature of work : Construction of Health Center with 8 rooms (Clinics, Pharmacy, Labs, Fence & Latrines) Location: Shakreen- El Fasher Town- North Darfur State No. Description Qty Unit

More information

GENERAL STOCK LIST. Toll Free Sales Fax Cavett Ave., Cincinnati, Ohio 45215

GENERAL STOCK LIST. Toll Free Sales Fax Cavett Ave., Cincinnati, Ohio 45215 GENERAL STOCK LIST Toll Free 1-866-284-8897 Sales Fax 513-563-8929 WWW.DISCOUNTDRAINAGE.COM 200 Cavett Ave., Cincinnati, 45215 DISCOUNT DRAINAGE SUPPLIES POLYVINYL CHLORIDE DRAINAGE (PVC) 4 thru 24 SDR35

More information

SPECIAL SPECIFICATION 3504 Septic Tank System

SPECIAL SPECIFICATION 3504 Septic Tank System 1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for

More information

FLOOR AND AREA DRAINS

FLOOR AND AREA DRAINS Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 22 13 19 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS SERIES 9100 - SUBMERSIBLE NON-CLOG PUMPS SERIES 9235 - DRY-PIT SUBMERSIBLE NON-CLOG PUMPS SERIES 9500 - STAINLESS STEEL SUBMERSIBLE NON-CLOG

More information

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification

More information

LIST STOCK GENERAL Toll Free. Sales Fax. Cincinnati

LIST STOCK GENERAL Toll Free. Sales Fax. Cincinnati www.discountdrainage.com GENERAL STOCK LIST Toll Free 1-866-284-8897 Sales Fax 513-563-8929 Cincinnati 513-563-8616 200 Cavett Ave. Cincinnati, 45215 The ALL-NEW 2015 DD APP is here. Scan the QR code with

More information

CONCRETE PRODUCTS. COURTBRACK, BLARNEY, CO. CORK TEL: (021)

CONCRETE PRODUCTS. COURTBRACK, BLARNEY, CO. CORK TEL: (021) CONCRETE PRODUCTS COURTBRACK, BLARNEY, CO. CORK TEL: (021) 4385872 Email: info@wmkiely.ie www.wmkiely.ie SEPTIC TANKS EN12566-1 CERTIFIED 3100 Litre Suitable for up to 6 people 2-3 bedroom house 4000 Litre

More information

Drainage and Erosion Control

Drainage and Erosion Control Drainage and Erosion Control Erosion Control To order Straw Waddle 020897 Straw Waddle 9" x 25 Roll 14 Rolls/ None 140209 Wood Stakes 1" x 2" x 18" 50 Pcs./Bndl. None Straw fiber rolls that control erosion

More information

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE. (f) The minimum requirements for construction, materials and foundations of grease traps shall be the same as those required for septic tanks, as prescribed in N.J.A.C. 7:9A-8.2. (g) The inlet and outlet

More information

PRE-CAST YARDS / LIGHTWEIGHT PANEL / HOLLOW CORE / TELECOM MANHOLE / MRTC [SUB-WAY] / PLASTIC SHIMS

PRE-CAST YARDS / LIGHTWEIGHT PANEL / HOLLOW CORE / TELECOM MANHOLE / MRTC [SUB-WAY] / PLASTIC SHIMS PRE-CAST YARDS / LIGHTWEIGHT PANEL / HOLLOW CORE / TELECOM MANHOLE / MRTC [SUB-WAY] / PLASTIC SHIMS LONG PUN ENTERPRISE PTE LTD SPACER SPECIALIST SDN BHD FORMWORK PRODUCT CATALOGUE PRE-CAST YARDS CATERPILLAR

More information

FABRICATION FACILITIES

FABRICATION FACILITIES FABRICATION FACILITIESF Norwalk Precast Molds Inc. is dedicated to serving the needs of the precast concrete industry. It is an old line company which has dependably served its customers since 1906. To

More information

PERMANENT PAVEMENT REPAIR NO SCALE

PERMANENT PAVEMENT REPAIR NO SCALE SAWCUT EXISTING PAVEMENT 2" BITUMINOUS CONCRETE SURFACE COURSE, CLASS 2 (MIN) CLEAN EDGE PRIOR TO PAVING AND PAINT WITH LIQUID BITUMEN. INSTALL SEALANT OVER JOINT UPON COMPLETION 2" BITUMINOUS CONCRETE

More information

Storm Drainage

Storm Drainage University of New Hampshire University of New Hampshire Scholars' Repository Division 33 Utilities Chapter 5 Technical Construction and Renovation Standards 4-23-2015 334100 - Storm Drainage Sandra Hickey

More information

Concrete Product Solutions

Concrete Product Solutions Concrete Product Solutions Product Catalog 2014-2015 3 About CONAC CONAC was established in 1985 to provide cost effective materials of the highest quality to manufacturers of precast concrete products.

More information

Residential Building Inspections

Residential Building Inspections Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved

More information

Septic Tanks: The Primary Treatment Device of Conventional Septic Systems

Septic Tanks: The Primary Treatment Device of Conventional Septic Systems Septic Tanks: The Primary Treatment Device of Conventional Septic Systems Yvonne A. Wood and Brad D. Lee Introduction Septic tanks play an essential role in effectively treating wastewater in areas without

More information

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN

More information

A. This Section includes the following sanitary drainage piping specialties:

A. This Section includes the following sanitary drainage piping specialties: Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

AWI MANUFACTURING. Quality Products Since USDA Certified. Stainless Steel Floor Drains

AWI MANUFACTURING.  Quality Products Since USDA Certified. Stainless Steel Floor Drains AWI MANUFACTURING Stainless Steel Floor Drains 4 Floor Drains 4 Hub Drains 4 Trench Drains 4 Floor Sinks 4 Cleanouts 4 P-Traps 4 Custom Drains USDA Certified Quality Products Since 1970 www.awimfg.com

More information

Complete Drainage System

Complete Drainage System Complete Drainage System Ideal for paths, driveways and domestic areas with corners & t sections Made in Australia from tough, durable and light-weight, UV-stabilised recycled plastic Hold down feet to

More information

Packaged Pump Stations

Packaged Pump Stations DELTA MEMBRANE SYSTEMS LTD packagedpumpsolutions Uniclass: L7316 CI/SfB: (52.9) X Packaged Pump Stations Delta Membrane Systems Limited delta house, Merlin way, North Weald, Epping, Essex, CM16 6hr t:

More information

B. Wiring Diagrams: For power, signal, and control wiring.

B. Wiring Diagrams: For power, signal, and control wiring. Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a

More information

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota Pump Tank and Pretreatment Inspection & Troubleshooting Sara Heger University of Minnesota sheger@umn.edu Evaluate Presence of Odor Odors are improper venting Check seals Lid Conduit Tank Access a. Access

More information

Evolution of Conventional Septic Systems

Evolution of Conventional Septic Systems jjj Homeowner Education Workshop Richfield Springs Community Center - February 2, 2013 Residential Conventional Septic Systems Overview by Bob Eichinger Onsite Engineering, PLLC Brief History of Conventional

More information

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 22 14 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

SEPTIC TANK CONSTRUCTION GUIDELINES

SEPTIC TANK CONSTRUCTION GUIDELINES SEPTIC TANK CONSTRUCTION GUIDELINES Septic tank for this airport will be designed/ built by the general contractor of the building facilities. At the time of the project design, availability of a septic

More information

Storm Drainage Structures

Storm Drainage Structures Storm Drainage Structures Tomorrow s Drainage System Today A DIVISION OF ADVANCED DRAINAGE SYSTEMS, INC. ADVANCED DRAINAGE SYSTEMS, INC. The Preferred Solution for Storm Drainage Applications. About Nyloplast-ADS

More information

On-lot System Component Requirements

On-lot System Component Requirements On-lot System Component Requirements All system components used with an on-lot system employing an Eljen GSF System must meet either the requirements of Title 25, Chapter 73 or the Eljen GSF Listing. The

More information

TYPICAL INSTALLATION INSTRUCTIONS

TYPICAL INSTALLATION INSTRUCTIONS TYPICAL INSTALLATION INSTRUCTIONS Environment One Grinder Pump Feature Identification 1. Grinder Pump Basin High density polyethylene (HDPE) 2. Accessway Cover Painted Steel 3. Electrical Quick Disconnect

More information

ARMTEC.COM. Proven quality and dependability in drainage solutions and water treatment

ARMTEC.COM. Proven quality and dependability in drainage solutions and water treatment ARMTEC.COM Drainage Solutions and WATER Treatment Proven quality and dependability in drainage solutions and water treatment DRAINAGE SOLUTIONS AND WATER TREATMENT Armtec is known for quality and dependability

More information

GENERAL STOCK LIST. Toll Free Sales Fax South Arlington Road, Akron, OH 44319

GENERAL STOCK LIST. Toll Free Sales Fax South Arlington Road, Akron, OH 44319 GENERAL STOCK LIST Toll Free 1-800-407-0011 Sales Fax 330-644-7429 WWW.DISCOUNTDRAINAGE.COM 2600 South Arlington Road, Akron, OH 44319 DISCOUNT DRAINAGE SUPPLIES POLYVINYL CHLORIDE DRAINAGE (PVC) 4 thru

More information

EnviroModule TM 2 installation guide

EnviroModule TM 2 installation guide EnviroModule TM 2 installation guide assembly excavation installation backfilling design examples contents Product specifications 2 Assembly 3 Excavation 5 Installation 6 Rainwater harvesting - residential

More information

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems: SECTION 221429 - SUMP PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related

More information

Diagnosing Performance. Mark Gross, Ph.D., P.E.

Diagnosing Performance. Mark Gross, Ph.D., P.E. Diagnosing Performance Mark Gross, Ph.D., P.E. Troubleshooting 17 May 2010 Diagnosing Poor System Performance First Things First Water usage? Residential Strength Wastewater? System location? Condensate,

More information

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial DRAINS: BATH,, SHOWER &, S COMMERCIAL SHOWER DRAINS GENERAL PURPOSE DRAINS FIT-FLUSH CLEAN-OUTS BATH WASTES BATH WASTES KITS/PARTS/COMPONENTS BATH DRAIN BODIES/ASSEMBLIES BATH DRAIN KITS/PARTS/COMPONENTS

More information

Introduction. Installation

Introduction. Installation ADVANCE CONCRETE & PRE-CAST HOLDING PTY LTD A.C.N.083 235 536 50 Victoria street Riverstone N.S.W. P.O Box130 Riverstone n.s.w. 2765 Phone 02 96276476 fax 02 96276478 Introduction To supply Grease Traps

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

Appendix 4. Bills of Quantities

Appendix 4. Bills of Quantities Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic

More information

Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Supports Radon Venting. North American Specialty Products

Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Supports Radon Venting. North American Specialty Products North American Specialty Products Installation Guide 3-in-1 Solution Forms Footings Drains Foundations Supports Radon Venting North American Specialty Products STEP-BY-STEP INSTRUCTIONS Rough Layout Begin

More information

3-in-1 Solution. Forms Footings Drains Foundations Vents Radon

3-in-1 Solution. Forms Footings Drains Foundations Vents Radon CertainTeed Installation Guide 3-in-1 Solution Forms Footings Drains Foundations Vents Radon STEP-BY-STEP INSTRUCTIONS Rough Layout Begin with the rough layout of the required number of standard 12' lineals,

More information

The Can t Miss Event of the Year!

The Can t Miss Event of the Year! The Can t Miss Event of the Year! Do you work in one of these fields? - Excavation - - Building - - Septic Installs - - Landscaping - - Service Provider - - Hardscaping - Then you need to be at --- HUGE

More information

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ONE PIPE LENGTH MAX (REFER TO 1/4/FT SLOPE (MIN) 5'-0 (MIN) OR 4 LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4x6 REFER TO TYPICAL EXCAVATION, VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE

More information

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2 - C 1 Product Detail Engineering Data Models... C2 Structural Support Models... C6 Engineering Specifications... C8 - C 2 Engineering Data Models REMARK: Do not use for construction. Refer to factory certified

More information

Defence ] Defence 9/14 A DIVISION OF STRONGFORM GROUP

Defence ] Defence 9/14 A DIVISION OF STRONGFORM GROUP ] VCI are a SCEC (Security Construction and Equipment Committee) endorsed manufacturer and supplier of Cable Pits and Locking Pit ccess Covers for all ustralian and other high security cable pit projects.

More information

SECTION UNDERGROUND ELECTRICAL CONSTRUCTION

SECTION UNDERGROUND ELECTRICAL CONSTRUCTION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 41 UNDERGROUND ELECTRICAL CONSTRUCTION A. This section specifies the furnishing, installation, and connection of precast manholes and pullboxes with ducts

More information

ENVIROMODULE 2 DESIGN AND INSTALLATION GUIDE. Assembly Excavation Installation Backfilling Pipe Connections Design Examples Structural Design

ENVIROMODULE 2 DESIGN AND INSTALLATION GUIDE. Assembly Excavation Installation Backfilling Pipe Connections Design Examples Structural Design ENVIROMODULE 2 DESIGN AND INSTALLATION GUIDE Assembly Excavation Installation Backfilling Pipe Connections Design Examples Structural Design STORMWATER SOLUTIONS CONTENTS Product specifications 3 Assembly

More information

Fabrication and Installation Table of Contents

Fabrication and Installation Table of Contents Fabrication and Installation Table of Contents HDPE AQUASHIELD PRODUCTS 2 Fabrication and Installation 2 System Fabrication 3 Aqua-Swirl Installation 4 Step 1 Excavation and Bedding 4 Step 2 Pipe Connection

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

Miscellaneous and Cast Iron Listings

Miscellaneous and Cast Iron Listings aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Strengthened Soil Wall Construction Manual

Strengthened Soil Wall Construction Manual Strengthened Soil Wall Construction Manual This information has been prepared by Shaw Technologies, Inc. as an aid in constructing their Strengthened Soil Wall system. Final determination of the suitability

More information

Smarter. Safer. Leaner.

Smarter. Safer. Leaner. Smarter. Safer. Leaner. Fast Installation and Removal Decrease Leading Edge Exposure by 87% OSHA Compliant Versatile and Reusable Use Perimeter Protection Posts During Construction: At Building Perimeter

More information

One Company. Many Solutions.

One Company. Many Solutions. One Company. Many Solutions. Imagine a drainage company that not only offers best in class products at a great price but...we ship within 48 hours on all of our stocked items. A 140,000 SF warehouse (

More information

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED Specifies requirements for construction and performance of an underground stormwater quality

More information

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures A Delivering Reliability Electrical Vaults Power & Energy-Underground Structures A The Benefits of Precast Vaults Electrical vaults house power cables and transformers, and are a preferred alternative

More information

CertainTeed. Canadian Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Vents Radon

CertainTeed. Canadian Installation Guide. 3-in-1 Solution. Forms Footings Drains Foundations Vents Radon CertainTeed Canadian Installation Guide 3-in-1 Solution Forms Footings Drains Foundations Vents Radon STEP-BY-STEP INSTRUCTIONS Rough Layout Begin with the rough layout of the required number of standard

More information

Beacon Hill Water & Sewer District Standard Specifications

Beacon Hill Water & Sewer District Standard Specifications Beacon Hill Water & Sewer District Standard Specifications STEP Sewer Systems Including: Design Criteria Standard Construction Drawings REVISED JANUARY 2012 Alternative sewer systems must meet the requirements

More information

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection PERMITS & INSPECTIONS 750 17th Street West Vancouver BC V7V 3T3 westvancouver.ca/permits t: 604-925-7040 f: 604-925-7234

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 33 3400 STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE 3.33' 3.0' 2.0' 4.33' 4.0' 3.0' 1.00' TO BACK OF CURB LINE TOP OF GRATE ELEV. - SEE PLAN NEENAH CASTING R-3067-V OR AS NOTED ON PLANS. "INFA-SHIELD" SEAL OR EQUAL. RINGS (2 MIN., 1' MAX. OF RINGS AND MORTAR).

More information

For Underground Burial or Under Slab Applications. Can Be Fabricated For Both Positive And Negative Pressure

For Underground Burial or Under Slab Applications. Can Be Fabricated For Both Positive And Negative Pressure For Underground Burial or Under Slab Applications. Can Be Fabricated For Both Positive And Negative Pressure Our supplier for what you and I would call "PVC Coated Metal" is Wheeling Service & Supply.

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1423 - STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION SANITARY WASTE INTERCEPTORS

SECTION SANITARY WASTE INTERCEPTORS SECTION 22 13 23 SANITARY WASTE INTERCEPTORS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE 5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE NUDURA Inc. has one of the most complete lineups of products and accessories available today in the construction industry. NUDURA s Integrated

More information

Acceptable Unacceptable

Acceptable Unacceptable 1. Introduction to forms 2. Different types of Pretreatment tanks. 3. Identify unacceptable conditions. 4. Evaluate the baffles & effluent screens 5. Measure sludge & scum, identify if tank needs cleaning.

More information

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork. PAGE 334000-1 SECTION 334000 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM) Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 03300 - Cast-in-Place Concrete.2 Section 05121 - Structural Steel for Buildings.3 Section 05500 - Metal Fabrications 1.2 REFERENCES.1

More information

Date of Authorization February 25, 2010 BMEC Authorization Number BMEC Application A BMEC Expiration Date February 26, 2015

Date of Authorization February 25, 2010 BMEC Authorization Number BMEC Application A BMEC Expiration Date February 26, 2015 777 Bay Street, 2 nd Floor 777, rue Bay, 2 e etage Toronto, Ontario, M5G 2E5 Toronto, Ontario, M5G 2E5 T: 416 585 4234 F: 416 585 7531 W: www.ontario.ca/buildingcode/ T: 416 585 4234 TC: 416 585 7531 W:

More information

Inflow pipe. Drain. Drain

Inflow pipe. Drain. Drain Inflow pipe Screened overflow Drain Foul flush diverter Screened intake Manhole cover Maximum water level Seal Inspection cover Possible local drainage through screen Drain Bottom sloped Screened outlet

More information

SMITH/ACO DRAINAGE SYSTEMS

SMITH/ACO DRAINAGE SYSTEMS SMITH/ACO DRAINAGE SYSTEMS Commercial Trench Drains EXPANSION JOINT TO ENGINEER S DETAIL CONCRETE BEDDING L ACO DRAIN Site Installation Manual 1 Polymer Concrete Drain Systems SMITH CUSTOMER DRIVEN SINCE

More information

Tank Functions. Solids removal by settling & floatation. Anaerobic digestion Storage of solids % solids removal

Tank Functions. Solids removal by settling & floatation. Anaerobic digestion Storage of solids % solids removal Tank Functions Solids removal by settling & floatation 60-80% solids removal Anaerobic digestion Storage of solids Average Removal of BOD, TSS, and Grease in Septic Tank Parameter Average Raw Sewage Influent

More information

GB-20. Submittal Specifications Installation Application Specific Details

GB-20. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL (53.3 cm) STANDARD: 2" plain end

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Art Mould Plastics "SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966"

Art Mould Plastics SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966 Art Mould Plastics "SUPPORTING THE REINFORCING CONCRETE INDUSTRY SINCE 1966" Table of Contents Individual Support Chairs Linden Chairs. 3 Sand Plates 3 Stackable Chair... 5 X-Chairs.. 7 Rod Spacers.. 8

More information

Underground Exhaust System

Underground Exhaust System Operation and Maintenance Manual Underground Exhaust MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 Underground Duct Construction Standards 1. Dig trench depth to allow for minimum distance from

More information

Table of contents Copyright ANDREAS STIHL AG & Co. KG 2017 (2)

Table of contents Copyright ANDREAS STIHL AG & Co. KG 2017 (2) 03-2016 D-GB Table of contents Copyright ANDREAS STIHL AG & Co. KG 2017 (2) 11.10.2017 Table of contents MS 150 TC 4 Cylinder with piston, Ignition system 6 Motor housing 9 Oil pump, Clutch 11 Chain sprocket

More information

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho DESIGN PACKAGE A WATER FEATURE HYDRAULIC DESIGN FOR COMMONS PARK Twin Falls, Idaho P16375-R5 6-16-17 Prepared by FOUNTAIN PEOPLE P.O. Box 807 4600 Highway 123 San Marcos, Texas 78666 SPECIAL DESIGN CONSIDERATIONS

More information

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS TABLE OF CONTENTS 1. TYPES OF STORM DRAIN PIPE AND JOINTS...2 2. MANHOLES, CATCH BASINS AND INLETS BLOCK AND BRICK...3 3. PRECAST MANHOLES, CATCH BASINS AND INLETS...4 4. STORM DRAIN STUBS...4 5. STORM

More information