1 EQUIVALENT INITIAL STRUCTURAL SAFETY ASSESSMENT Factory Tetulzhora Union, Hemayetpur, Savar Savar Dhaka 01 Mar 2014 The Alliance for Worker Safety Page 1/10

2 01 Mar 2014 Introduction to the Report The following report contains a site profile and summary of non-conformities identified during an onsite assessment commissioned by the Alliance for Worker Safety (Alliance) and conducted by a third-party Qualified Assessment Firm (QAF). The assessment was conducted against the Alliance for Worker Safety Assessment Protocols (APs) and Fire Safety and Structural Integrity Standard, which is harmonized with the factory assessment guidelines developed by University of Engineering and Technology (BUET) for the National Tripartite Plan of Action (NTPA). The goal of the Alliance process is to provide clear and practical technical requirements by which i Ready Made Garment (RMG) Factories producing for Alliance members may be consistently and fairly evaluated for fire, structural, and electrical safety in a non-duplicative manner. Each assessment will prompt action plans that will be used by RMG factories to systematically and sustainably improve safety conditions for garment workers. Beyond tracking and reporting on action steps taken in a transparent manner, the Alliance organization and its members will seek to further support factory improvements through technical assistance, training, implementation support for functional Worker Committees, and in some cases financial assistance and wage support for workers if factories are closed for remediation. The contents of the report do not constitute a guarantee of compliance with the applicable laws, the Alliance Standard or the absolute or continued safety against fire, electrical and/or structural integrity issues that may lead to injury or loss of life. The report is designed to provide a non-exhaustive summary of risk issues, based on a limited sampling and duration of time onsite by the named QAF. Neither the QAF nor the Alliance can certify or guarantee the quality, outcome, or effectiveness of actions taken in response to the report. For more information and report feedback please go to: The Alliance for Worker Safety Page 2/10

3 01 Mar 2014 GENERAL INFORMATION General Information Factory Country: Province: City: Dhaka Savar Zip Code: 1340 Audit Duration: Re-Audit: 2 Days Re-Audit After 0 Months Draft Report Date : Final Report Date : Are all Action Items From Previous Assessment Completed?: Buildings in Complex : Number of Building Levels (Stories) : Approximate Building Area (SF) : Date of Building Construction : N/A There are 10 buildings in the premises out of which one is main production building and four are ancillary buildings. Other buildings belong to sister concerns of Aboni Knit Wear. The buildings are named as: 1) Eight Story RCC Main Production building, 2) Single story prefab finished goods shed-1, 3) Single storyprefab finished goods shed-2, 4) Two story guard room and day care shed, 5) Four story RCC Generator and substation building. 1) Eight Story RCC Main Production building: Stories above grade: 8, Stories below grade: 0, Occupied levels: 8, 2) Single storyprefab finished goods shed-1:, Stories above grade: 1, Stories below grade: 0, Occupied levels: 1, 3) Single storyprefab finished goods shed-2: Stories above grade: 1, Stories below grade: 0, Occupied levels: 1, 4)Two story guard room and day care shed: Stories above grade: 2, Stories below grade: 0, Occupied levels: 2, 5) Four story RCC Generator and substation building: Stories above grade: 4, Stories below grade: 0, Occupied levels: 4. Total area of buildings in the factory premises: sft. Building wise breakdown as follows: 1) Eight Story RCC Main Production building: sft (Ground floor: sft, 1st floor: sft, 2nd floor: sft, 3rd floor: sft, 4th floor: sft, 5th floor: sft, 6th floor: sft, 7th floor: sft Roof : sft (unoccupied) ) 2) Single storyprefab finished goods shed-1: sft, 3) Single storyprefab finished goods shed-2: sft, 4) Two story guard room and day care shed: sft, (Ground floor: sft, 1st floor: sft), 5) Four story RCC Generator and substation building: sft (Ground floor: sft, 1st floor: sft, 2nd floor: sft, 3rd floor: sft Roof : sft ) Factory personnel informed the date of construction as follows: 1) Eight Story RCC Main Production building: Started in 2001 and finished in 2002, 2) Single storyprefab finished goods shed-1: Finished in 2006, 3) Single The Alliance for Worker Safety Page 3/10

4 01 Mar 2014 storyprefab finished goods shed-2: Finished in 2006, 4)Two story guard room and day care shed: Finished in 2004, 5) Four story RCC Generator and substation building: Finished in Date of Last Building Renovation/Addition : Is the Building mixed use?: Ancillary Structures in Complex : Number of Ancillary Levels (Stories) : Approximate Ancillary Structures Area (SF) : Number of Occupants : Exterior Facade Description : Structural System Description : A single storey shed has been so far used as driver waiting room. Renovation of this shed is going on and intended to be used as day care. No 1) Single storey prefab finished goods shed-1, 2) Single storey prefab finished goods shed-2, 3) Two storey guard room and day care shed, 4) Four storey RCC Generator and substation building. 1) Single storey prefab finished goods shed-1: Floors above grade: 1, Floors below grade: 0, Occupied levels: 1, 2) Single storey prefab finished goods shed-2: Stories above grade: 1, Stories below grade: 0, Occupied levels: 1, 3) Two story guard room and day care shed: Stories above grade: 2, Stories below grade: 0, Occupied levels: 2, 4) Four story RCC Generator and substation building: Stories above grade: 4, Stories below grade: 0, Occupied levels: 4. 1) Single storyprefab finished goods shed-1: sft, 2) Single storyprefab finished goods shed-2: sft, 3) Two story guard room and day care shed: sft, (Ground floor: sft, 1st floor: sft), 4) Four story RCC Generator and substation building: sft (Ground floor: sft, 1st floor: sft, 2nd floor: sft, 3rd floor: sft Roof : sft ) Total number of occupants: ) Eight Story RCC Main Production building: 2433 (Ground floor: 398, 1st floor: 395, 2nd floor: 409, 3rd floor: 403, 4th floor: 398, 5th floor: 410, 6th floor: 20, 7th floor: 0, 8th floor: 0), 2) Single story prefab finished goods shed-1: 1, 3) Single story prefab finished goods shed-2: 1, 4) Two story guard room and day care shed: 4, 5) Four story RCC Generator and substation building: 4 (Ground floor: 2, 1st floor: 2, 2nd floor: 0, 3rd floor: 0). The building is RCC frame structure with infilled masonry wall. Exterior face of the masonry wall is of plaster and paint works and the windows are of sliding glass type and main gate is sliding type metallic. The building is a RCC frame structure. the nature of foundation is cast in-situ pile foundation. The Alliance for Worker Safety Page 4/10

5 01 Mar 2014 ASSESSMENT FINDINGS Structural System Design Is a clear and redundant load path to resist lateral loads provided? The main factory building is designed as three separate buildings, but it is constructed as a single building. Therefore, the lateral load path is changed and also its lateral load path is not clear and redundant. Document Review: Confirmed by reviewing structural drawings. Have a qualified structural engineer complete further analysis of the structure and develop a remediation plan if required. Alliance Standards Part 8 Section 8.17 Design for Lateral Loads and BNBC Part 6 Section 1.5 Are credible structural design documents available for review and kept on site? Non-Compliance Level: 2 A set of structural design document is available on-site for review. However, the design report is not available which is required as per BNBC 2006 clause Document Review: Design report unavailable. Have a qualified structural engineer prepare credible as-built documents based on the requirements of Part 8 Section 8.19 of the Alliance Standard. Alliance Standard Part 8 Section 8.19 Required Structural Documentation for New and Existing Factories The Alliance for Worker Safety Page 5/10

6 01 Mar 2014 Have provisions been made in floors or decks for a concentrated load (such as heavy equipment, water tanks, stored materials, etc) applied at a location wherever this load acting upon an otherwise unloaded floor would produce stresses greater than those caused by a uniform load? Non-Compliance Level: 2 There are 4 plastic water tanks, 2 having capacity of 3 tons and 2 having capacity of 1 ton of water storage. Also, transmission tower found in 7th floor roof. There is no analytical information on the provision of these additions in the building design. Document Review: No analytical information availble., Visual Assessment, Document Review: No analytical information availble., Visual Assessment Engage a qualified structural engineer to confirm and document that provisions have been made to accommodate concentrated loads. If provisions have not been made, have a qualified structural engineer develop a remediation plan. Alliance Standard Part 8 Section 8.13 and 8.14 Are Certificates of Occupancy available for review? Low Non-Compliance Level: 1 The Certificate of Occupancy is not available. Document Review: Document unavailable. Provide Certificates of Occupancy for review. Alliance Standard Part 8 Section 8.3 Preliminary Structural Assessment Structural System Construction Have all areas of needed maintenance, including areas with efflorescence, dampness, standing water on rooftops, and corrosion been addressed. Non-Compliance Level: 2 Standing water have been found at 1st floor north-east corner and dampness has also been found at 4th floor of the building. Corrosion was also observed in roof top rebars of columns. The Alliance for Worker Safety Page 6/10

7 01 Mar 2014 Visual Assessment: Visually confirmed. Under guidance from a qualified structural engineer, address all areas of needed maintenance by correcting the identified issues. Alliance Standard Part 8 Section 8.26 Durability and Maintenance Are any structural elements constructed with MCAC exposed to rainfall or other sources of water sealed with a protective coating to prevent water intrusion? Non-Compliance Level: 2 The roof of the building is of MCAC aggregate but no protective sealing is available. Visual Assessment: Visually the roof of the building is of MCAC aggregate but no protective sealing is available. Provide a protective coating at the structural elements constructed with MCAC exposed to rainfall or other sources of water. Have protective coating approved by the Alliance or a qualified structural engineer. Or provide 2% slope on the exposed surface to Alliance Standards Part 7 Building Materials Section 7.2 Masonry-chip aggregate concrete (MCAC). Are all non-structural elements suspended from, attached to, or resting atop the structure adequately anchored and braced to resist earthquake forces? Non-Compliance Level: 2 In the store rooms of ground, 1st, 5th and 6th floors, there are racks which are not braced for earthquake force. There are 4 plastic water tanks with considerable height which are not braced or anchored properly. Visual Assessment: Visual inspection shows that in the store room of ground, 1st, 5th and 6th floor, there are racks which are not braced for earthquake force. There are 4 plastic water tanks with considerable height, which are not braced or anchored prop Adequately anchor and brace all non-structural elements to resist earthquake forces to comply with the BNBC and Alliance Standard. 15 Sep 2014 The Alliance for Worker Safety Page 7/10

8 01 Mar 2014 Alliance Standards Part 8 Section 8.18 Seismic Bracing of Key Non-Structural Elements and 2006 BNBC Part 6 Are structural steel members free of corrosion, physical damage or other types of deterioration? Non-Compliance Level: Apply protective coating on steel members. Alliance Standard Part 8 Section 8.26 Structural Safety Programs Is a program in place to ensure that the live loads for which a floor or roof is or has been designed will not be exceeded? There is no program that will ensure that the designated load in each floor will not be exceeded Document Review: Confirmed by reviewing documents. Develop a program to ensure that all live loads for which a floor or roof has been designed for will not be exceeded. The designated Load Manager shall oversee this program and ensure it is enforced. 21 Jul 2014 Alliance Standard Part 13 Section 13.7 and Part 8 Section 8.9. Have Load Plans been prepared for each floor documenting the actual maximum operational loading that is intended and/or allowable on each floor. Low Load Plans includs the actual maximum operational loading that is intended and/or allowable on each floor. However, the load plans provided by Aboni Knitwear only includes the existing loading condition of the floor. Also, they do The Alliance for Worker Safety Page 8/10

9 01 Mar 2014 not include the scaled layout of workstations, operating equipment. Document Review: Confirmed by reviewing documents. Have a qualified structural engineer develop Floor Loading Plans per the requirements of Part 8 Section Alliance Standard Part 8 Section 8.10 Floor Loading Plans (Load Plans) Are Floor Load Plans posted as required? Low Load plans have been prepared but not as per Alliance standard. Visual Assessment: Visual assessment shows that load plans have been prepared but not as per Alliance standard. Have a qualified structural engineer prepare load plans including the information required in Section 8.20 of the Alliance Standard. Alliance Standard Part 8 Section Are areas used for storage of work materials and work products, clearly marked to indicate the acceptable loading limits as described in the Load Plan for that floor? Low Available load plans do not comply with the standard. Loading limits are not mentioned in the provided load plans. Document Review: Documents reviewed on site., Visual Assessment, Document Review: Documents reviewed on site., Visual Assessment Prepare Load Plan as per Alliance Standard. Provide signage or the appropriate markings at all areas used for storage to indicate the acceptable loading limits detailed in the Load Plan. Alliance Standard Part 8 Section 8.11 Floor Load Markings Is a designated representative (Factory Load Manager), who is onsite full time, trained regarding the structural floor capacity, and serves as an ongoing The Alliance for Worker Safety Page 9/10

10 01 Mar 2014 vendor resource and monitor of operational factory floor loadings? Low There is no designated representative (Factory Load Manager), who is onsite full time, trained regarding the structural floor capacity, and serves as an ongoing vendor resource and monitor of operational factory floor loadings. Document Review: Confirmed by document review. Designate a representative as the Factory Load Manager. The Factory Owner shall ensure that at least one individual, the Factory Load Manager who is located onsite full time at the factory, is trained in calculating operational load characteristics of the 21 Jul 2014 Alliance Standards Part 8 Section 8.9 Factory Load Manager The Alliance for Worker Safety Page 10/10

INITIAL STRUCTURAL INTEGRITY ASSESSMENT REPORT (SIAR)

INITIAL STRUCTURAL INTEGRITY ASSESSMENT REPORT (SIAR) INITIAL STRUCTURAL INTEGRITY ASSESSMENT REPORT (SIAR) Factory Name: Karardi, Shibpur, Narsingdi, Narsingdi Dhaka Bangladesh 10 May 2013 The Alliance for Bangladesh Worker Safety Page 1/15 10 May 2013 Introduction

More information

EQUIVALENT INITIAL STRUCTURAL SAFETY ASSESSMENT

EQUIVALENT INITIAL STRUCTURAL SAFETY ASSESSMENT EQUIVALENT INITIAL STRUCTURAL SAFETY ASSESSMENT Factory Plot No. 74, Block -K, Rupnagar Ind. Area, Secti, Dhaka Dhaka Dhaka The Alliance for Worker Safety Page 1/5 Introduction to the Report The following

More information

BUILDING INTEGRITY DEA SUMMARY REPORT

BUILDING INTEGRITY DEA SUMMARY REPORT BUILDING INTEGRITY DEA SUMMARY REPORT SUPPLIER NAME UNITS AUDITED Opex Mills SSL2 Building 4X Generator Building 6X Generator Building Denim Generator Building Rope Denim Generator Building SSL Generator

More information

Structural Inspection Report

Structural Inspection Report Revision: Issue 2 Date: 23 rd June 2014 Cherry Pvt. Ltd. Florence Fashions Ltd. Ultimate Ltd. Chandand Fashion Ltd. Joy Fashion Ltd. Structural Inspection Report Authors: Adrian Ryan, Cathal Mac an tsearraigh

More information

Libas Textiles Ltd (9500)

Libas Textiles Ltd (9500) Revision : Issue 01 Date: 28.03.2014 Libas Textiles Ltd (9500) Nishchintopur, Mouchak, Kaliakoir, Gazipur, Bangladesh. (+24.01773N, +90.27978E) 22.MARCH.2014 Client Summary Report Observations & Actions

More information

ABA Fashions Ltd. Plot #9, Block F, Tongi, Gazipur-1710 ( N, E) 08 MARCH 2014

ABA Fashions Ltd. Plot #9, Block F, Tongi, Gazipur-1710 ( N, E) 08 MARCH 2014 ABA Fashions Ltd. Plot #9, Block F, Tongi, Gazipur-1710 (23.885176N, 90.399821E) 08 MARCH 2014 1 2 Observations 3 Highly stressed columns Cursory calculations indicate column at a high working stress.

More information

A-One Polar Ltd. Bhulta,Rupgonj,Narayangonj. ( , ) 27th April 2014

A-One Polar Ltd. Bhulta,Rupgonj,Narayangonj. ( , ) 27th April 2014 1 A-One Polar Ltd Bhulta,Rupgonj,Narayangonj. (23.754782,90545710) 27th April 2014 2 Observations Observations Knitting & Garments building Building 1 1 3 4 Observations Roof structure: no roof bracing

More information

Apparel Gallery Ltd.

Apparel Gallery Ltd. Apparel Gallery Ltd. 147-148, Norshinghpur, Asulia, Savar, Dhaka (23.929985N,90.304914E) 23 March 2014 1 2 Observations Building 1 Heavy loading due to raised floor area on Ground Floor 3 Building 1 Raised

More information

BUILDING INTEGRITY SUMMARY REPORT

BUILDING INTEGRITY SUMMARY REPORT BUILDING INTEGRITY SUMMARY REPORT SUPPLIER NAME SUPPLIER ADDRESS AUDIT DATE January 2014 AUDIT PERFORMED BY Cosmopolitan Industries Pvt Ltd Khejur Bagan, Bara Ashulia, Savar, Dhaka, Bangladesh Department

More information

Abanti Color Tex Ltd. Plot-S, A-646, Shashongaon Enayetnager, Fatullah, Narayangonj ( E, N) 28 June 2014

Abanti Color Tex Ltd. Plot-S, A-646, Shashongaon Enayetnager, Fatullah, Narayangonj ( E, N) 28 June 2014 1 Abanti Color Tex Ltd. Plot-S, A-646, Shashongaon Enayetnager, Fatullah, Narayangonj (90.476444E, 23.622806N) 28 June 2014 2 Preliminary calculations suggest columns in Units 1 and 2 are highly stressed

More information

January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options

January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options River Tower at Christina Landing Wilmington, DE Joseph Bednarz Structural Option Faculty Advisor: Dr. Boothby Executive Summary January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign

More information

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1% CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE EXAM ID: I1 80 multiple-choice questions 3-1/2-hour time limit Open book 01. GENERAL ADMINISTRATION 6% 0101. Project Administration 1% Verify that

More information

BUILDING PERMIT APPLICATION PACKAGE

BUILDING PERMIT APPLICATION PACKAGE BUILDING PERMIT APPLICATION PACKAGE NOTICE TO BUILDING PERMIT APPLICANTS In addition to completed applications forms, the following documentation is required to accompany all building permit applications

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To

More information

UNIT 9 INSPECTION AND QUALITY CONTROL

UNIT 9 INSPECTION AND QUALITY CONTROL UNIT 9 INSPECTION AND QUALITY CONTROL Inspection and Quality Control Structure 9.1 Introduction Objectives 9.2 Need for Inspection and Quality Control 9.3 Principles of Inspection 9.4 Major Items in Construction

More information

BUILDING INTEGRITY SUMMARY REPORT

BUILDING INTEGRITY SUMMARY REPORT BUILDING INTEGRITY SUMMARY REPORT SUPPLIER NAME UNITS AUDITED Opex Mills 4X 6X Denim Rope Denim SSL SSL3 Utility Diesel SUPPLIER ADDRESS AUDIT DATE January 2014 AUDIT PERFORMED BY AUDIT TEAM Kanchpur,

More information

Plan Check No. Checked by: An Appointment Is Required for Verification

Plan Check No. Checked by: An Appointment Is Required for Verification SUPPLEMENTAL CORRECTION SHEET UNREINFORCED MASONRY (URM) RETROFIT ( 2002 LABC ) Plan Check No. Checked by: Permit Appl. # An Appointment Is Required for Verification Job Address: For appt. call: APPLICATION

More information

Mr. Eric Ryffel, Manager October 5, 2015 Sanibel Beach Club 626 Nerita Street Sanibel Island, Florida 33957

Mr. Eric Ryffel, Manager October 5, 2015 Sanibel Beach Club 626 Nerita Street Sanibel Island, Florida 33957 TRC Worldwide Engineering Restoration & Inspection, LLC 11926 Fairway Lakes Drive Fort Myers, Florida 33913 Phone: (239) 939-1414 F: (239) 278-4289 www.trcww.com C.O.A. No. 30761 Mr. Eric Ryffel, Manager

More information

What is NUFORM HOUSE KIT?

What is NUFORM HOUSE KIT? Introduction Nuform Building Technologies Inc. (NUFORM ) is creating a better way to deliver affordable housing the NUFORM HOUSE KIT is a solution for creating neighborhoods where people live with pride

More information

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE 1.01! DESCRIPTION OF WORK: The contractor shall provide all labor, materials, equipment and tools necessary for the complete installation of

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns. PAGE 051200-1 SECTION 051200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently

More information

DESIGN CRITERIA. Allowable Stress Design (ASD) AISC-1999.

DESIGN CRITERIA. Allowable Stress Design (ASD) AISC-1999. DESIGN CRITERIA 1. INTRODUCTION This appendix summarizes the codes, standards, criteria, and practices that are generally used in the design and construction structural engineering system for the Sarker

More information

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Plan Check/PCIS App #: Job Address: P.C. Engineer: Phone: (E -mail: first name.last name@ lacity.org) For instructions and other information,

More information

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW 27 September 2007 prepared by: J. CHRIS EVANS ARCHITECT 3220 E. Terra Alta Blvd. No. 9 Tucson, Arizona 85716 520.319.8835 evansarch@hotmail.com

More information

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit: TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION 355-7575 Ext. 395 Needed to Obtain Permit: 1. Building Permit Application, and/or residential plumbing permit application, as applicable, to be

More information

Commercial Tax Abatement

Commercial Tax Abatement A confirmation letter is issued by the City upon receipt of this application. This application is not effective and not considered filed until the confirmation letter has been issued. Filing does not assure

More information

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004 CITY OF MERCER ISLAND 9611 SE 36 th Street, Mercer Island, Washington 98040-3732 PHONE (206) 236-5300 FAX (206) 236-3645 TDD (206) 232-9598 www.ci.mercer-island.wa.us INTERNATIONAL BUILDING CODE - ADOPTION

More information

Hollow Core Slabs Applications

Hollow Core Slabs Applications NORDIMPIANTI P R O D U C T S APPLICATIONS T U R N K E Y S E R V I C E G L O B A L Hollow Core Slabs Applications Hollow Core Slabs Technology for the Precast and Prestressed Concrete Industry HOLLOW RESIDENTIAL,

More information

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS) 1102 4 th Street Telephone: 306-634-1819 Estevan, Saskatchewan, Canada Fax: 306-636-2199 S4A 0W7 INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

More information

Specification Lightning Protection Systems

Specification Lightning Protection Systems Specification Lightning Protection Systems General: Summary A) This Section specifies the lightning protection system for the building(s) or structure(s). This system provides safety for the building and

More information

PRESCRIPTIVE COMPLIANCE METHOD

PRESCRIPTIVE COMPLIANCE METHOD CHAPTER PRESCRIPTIVE COMPLIANCE METHOD 3 SECTION 301 GENERAL 301.2 Building materials. Building materials shall comply with the requirements of this section. 301.2.1 Existing materials. Materials already

More information

Reinforced concrete double walls

Reinforced concrete double walls Reinforced concrete double walls Build faster, pay less. Strength in building technology Uses The Kerkstoel reinforced double walls consist of two slabs of reinforced concrete joined to each other by lattice

More information

DIVISION 9 FINISHES. This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards

DIVISION 9 FINISHES. This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards DIVISION 9 FINISHES This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards 1 Table of Contents SECTION 09 05 13 COMMON FINISHES 2 SECTION 09 51 23 ACOUSTICAL

More information

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints. SECTION 09200 PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The extent of lath and plaster work is shown on the drawings and in schedules and includes interior and exterior plaster work, and fibreglass

More information

Lida Textile & Dyeing Ltd. Structural Inspection Report

Lida Textile & Dyeing Ltd. Structural Inspection Report Revision: Issue 1 Date: 9 th February 2015 Lida Textile & Dyeing Ltd. Ltd Holding No. 100/2, Block-B, East Chandura, Ward-8, Shafipur, Kaliakair, Gazipur. (24.036527, 90.272019) 4 th February 2015 Structural

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND STATE UNIVERSITY CONSTRUCTION FUND The following checklist show the general items required by the Agreement and the Program Directives. Unless included in the lump sum fee or the Schedule B of the Consultant

More information

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider Executive Summary: The FDA-CDRH Laboratory is currently being built on the Food and Drug Administration s White Oak Consolidation Campus. It is a four story building with a full below grade ground floor

More information

City of Richmond Zoning Ordinance Page 12-1

City of Richmond Zoning Ordinance Page 12-1 ARTICLE 12 BUILDING DESIGN AND COMPOSITION Section 12.01 Purpose. High quality architectural design and building composition are important elements in reinforcing a comfortable, human-scale environment,

More information

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS 1 LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS Thomas Castle, S.E. 2 This presentation is published by the Cold-Formed Steel Engineers Institute ( CFSEI ). The information herein shall not constitute

More information

Property Condition Assessment

Property Condition Assessment Property Condition Assessment Pewaukee, WI 53072 Inspection Date: 1/6/15 Prepared For: Report Number: Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar Dr. Pewaukee, WI 53072

More information

The designer shall also submit additional information required by the University as described and underlined below.

The designer shall also submit additional information required by the University as described and underlined below. I. Structural Engineering Submissions The designer shall submit all information required by the State Construction Office (SCO) as described in the State Construction Manual Chapter 300 - Project Design

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes. 6. ENGINEERING SYSTEMS REQUIREMENTS C30 INTERIOR FINISHES SYSTEMS REQUIREMENTS INTERIOR FINISHES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT Level 2

More information

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION: SECTION 13 05 41 SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED 1-25-13 PART 1 GENERAL 1.1 DESCRIPTION: A. Provide seismic restraint in accordance with the requirements of this section

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not

More information

General Commercial Energy Provisions

General Commercial Energy Provisions PART II General Commercial Energy Provisions Section 3: General Commercial Energy Provisions Section 4: Administration and Enforcement Mmaxer/www.Shutterstock.com 19 Section 3 General Commercial Energy

More information

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08 Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08 Table of Contents 1. Title 2. Designation 3. List of Figures 4. Scope 5. Referenced

More information

RAPID STRUCTURAL ASSESSMENT REPORT

RAPID STRUCTURAL ASSESSMENT REPORT Structure Type: SUPERSTRUCTURE Work Order: 5540 Facility Name: Pier 68 Warehouse FIN: 1680036 Building- Bldg. # 36 Asset Number: 1680-BLDG36 Facility Code: 3490 Asset Activity: STRUCTURE TWO YR Port Engineer:

More information

Wall bracing panel requirements

Wall bracing panel requirements Wall bracing panel requirements Building Inspections Exterior and interior walls must be braced in accordance with Minnesota State Building Code section R602 to resist wind loads and racking. Locations,

More information

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL Permit Application #: Date: mm/dd/yy Project Address Applicant s Name NOTE TO PERMIT APPLICANTS: All permit applications must

More information

SUBSTANTIAL IMPROVEMENT

SUBSTANTIAL IMPROVEMENT SUBSTANTIAL IMPROVEMENT General Discussion The following discussion addresses several of the issues surrounding the NFIP regulations concerning substantial improvement and substantial damage. The attached

More information

Structural Inspection

Structural Inspection General: Background: An inspection and structural analysis have been performed for the purpose of evaluating the buildings structural systems and components. A full set of structural drawings was utilized

More information

Facility Assessment Report, Montgomery Independent School District

Facility Assessment Report, Montgomery Independent School District NATATORIUM CAMPUS DATA NATATORIUM 22628 Hwy 105 West, Montgomery TX 77356 Year Built 2009 Approx. Total Square Footage Grades Served 30,420 n/a Current Enrollment n/a Building Levels 1 1 MASTER PLAN 2

More information

Building Inspection Report

Building Inspection Report Building Inspection Report Sample Commercial Inspection Report Inspection Date: Prepared For: Prepared By: Professional Property Inspection Consultants 4857 Winterset Drive Columbus, OH 43220 (614) 459-5941

More information

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code. SECTION 05400 COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Premier Inn, Wilson Street, Middlesbrough, TS1 1AE. Site progress report. February 2017

Premier Inn, Wilson Street, Middlesbrough, TS1 1AE. Site progress report. February 2017 Premier Inn, Wilson Street, Middlesbrough, TS1 1AE Site progress report February 2017 Site set up Currently 4 weeks in to the build the site has been cleared and hoardings have been erected. Welfare cabins

More information

Technical Report 3. Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R

Technical Report 3. Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R Technical Report 3 Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R Site and Location La Jolla Commons, San Diego, California General

More information

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION ORNAMENTAL ALUMINUM FENCING SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Avant Garde Fashion Ltd. Ring Shine Textiles Ltd.

Avant Garde Fashion Ltd. Ring Shine Textiles Ltd. Avant Garde Fashion Ltd. Ring Shine Textiles Ltd. Plots 170-176 & 224-260, Extension Area, DEPZ, Ganakbari, Savar, Dhaka, Bangladesh (23.945218 N,90.27939 E) 7 May 2014 1 2 Observations 3 Structural design

More information

BUILDING CODE VARIANCE

BUILDING CODE VARIANCE BUILDING CODE VARIANCE April 2009 06-BCV-011-R1 Page 1 of 8 DISCUSSION MULTI-LEVEL STORAGE RACKING SYSTEMS The Alberta Building Code 2006 contains no specific requirements for multi-level storage racking

More information

CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE

CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE TESTING APPLICATION STANDARD (TAS) 202-94 CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE 1. Scope 1.1 This protocol covers procedures

More information

Establishing the resilience of timber framed school buildings in New Zealand

Establishing the resilience of timber framed school buildings in New Zealand Establishing the resilience of timber framed school buildings in New Zealand D. Brunsdon Kestrel Group J. Finnegan Aurecon N. Evans Opus International Consultants G. Beattie & D. Carradine BRANZ Ltd J.

More information

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online): 2321-0613 Seismic analysis of RC Building Frame with Different Bracing Systems Mohammed Ali Khan

More information

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for seismic analysis Analysis done using structural designing

More information

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION INTRODUCTION Objective of provisions: The provisions of IEBC Appendix Chapter A3 are intended to reduce hazard of earthquake-induced damage (IEBC A301.1). These provisions are not intended to eliminate

More information

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street CITY OF ANDERSON BUILDING AND CODES 601 South Main Street Plan Review Notes (STREET ADDRESS) ANDERSON, SC Plan Review Number: Building Plans prepared by: Plans Signed by: Project Name: Plans Received:

More information

REPORT on remediation progress at RMG

REPORT on remediation progress at RMG QUARTERLY AGGREGATE REPORT on remediation progress at RMG factories covered by the Accord Statistics as of April 1st, 1 2 3 4 May 8 TABLE OF CONTENT SUMMARY.... 4 INSPECTIONS UPDATE.... 5 INSPECTION REPORTS

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

APPENDIX B RESIDENTIAL DEVELOPMENT DETAILS

APPENDIX B RESIDENTIAL DEVELOPMENT DETAILS Manhasset Crest Draft Environmental Impact Statement APPENDIX B RESIDENTIAL DEVELOPMENT DETAILS Manhasset Crest Draft Environmental Impact Statement Appendix B -1 Manhasset Crest Design Guidelines MANHASSET

More information

Technical Assignment 1 Construction Project Management

Technical Assignment 1 Construction Project Management Technical Assignment 1 Construction Project Management Technical Assignment 1-1 - Table of Contents A. Executive Summary.3 B. Project Summary Schedule.4 C. Building Systems Summary 5 D. Project Cost Evaluation..8

More information

FACT SHEET #2 DECK INFORMATION

FACT SHEET #2 DECK INFORMATION Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 FACT SHEET #2 DECK INFORMATION BACKGROUND The provisions of the PAUCC. ICC Property Maintenance

More information

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord. ARTICLE 987. PD 987. SEC. 51P-987.101. LEGISLATIVE HISTORY. PD 987 was established by Ordinance No. 30512, passed by the Dallas City Council on June 14, 2017. SEC. 51P-987.102. PROPERTY LOCATION AND SIZE.

More information

City of Tacoma Planning and Development Services

City of Tacoma Planning and Development Services City of Tacoma Planning and Development Services ORDINANCE NO. 28155 Adopt and Amend the City s Building Code; amending Title 2 of the Tacoma Municipal Code, implement the 2012 International Building,

More information

Chapter 1: Application and Administration

Chapter 1: Application and Administration Chapter 1: Application and Administration General Comments This chapter provides provisions regarding the purpose, scope, application, and administration of subsequent requirements of ICC 500. In addition

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-05 21 00 (May 2015) --------------------------- Preparing Activity: USACE Superseding UFGS-05 21 13 (August 2009) UFGS-05 21 16 (August 2009) UFGS-05 21 19 (July 2007)

More information

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition Spray Polyurethane Foam Design Guidance Insulation and Air Barrier Requirements of the 2012 I-Codes Spray Foam Coalition about the collaboration the center for the polyurathanes industry (CPI) of the

More information

First Revision No NFPA [ Section No ]

First Revision No NFPA [ Section No ] First Revision No. 1001-NFPA 5000-2015 [ Section No. 7.2.5.6.8 ] Global FR-6108 7.2.5.6.8 Exterior Nonbearing Walls. Exterior nonbearing walls tested shall be permitted when tested in accordance with,

More information

4. Construction Analysis Façade Sequencing

4. Construction Analysis Façade Sequencing 4. Construction Analysis Façade Sequencing Problem Statement As a developer catering to Class-A tenants, the owners of are placing a strong emphasis on the occupancy schedule for the office spaces. The

More information

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories 04 00 00 MASONRY 04 01 00 Maintenance of Masonry 04 01 20 Maintenance of Masonry 04 05 13 Masonry Mortaring 04 05 23 Masonry Accessories 04 20 00 UNIT MASONRY 04 21 00 Clay Unit and Brick Veneer 04 22

More information

Best Buy Corporate Building D (4) Richfield, MN

Best Buy Corporate Building D (4) Richfield, MN Best Buy Corporate Building D (4) Thesis Proposal Professor Boothby December 12 th, 2008 Executive Summary: The Best Buy Corporate Building D is a 6 story building with a total area of 304,610 square feet.

More information

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis Zasiah Tafheem 1, A.S.M Rubaiat Nahid 2, Tanzeelur Rahman

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

SPACE TYPE: OUTSIDE PARKING (STRUCTURE) SPACE TYPE: OUTSIDE PARKING (STRUCTURE) Construction Criteria The unit costs for Outside Parking (Structure) space types are based on the construction quality and design features in the following table.

More information

A/E REVIEW CHECKLIST STRUCTURAL

A/E REVIEW CHECKLIST STRUCTURAL A/E REVIEW CHECKLIST STRUCTURAL Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Site and Landscape, Architectural, Structural, Plumbing,

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM STATEMENT OF SPECIAL INSPECTION FORM Project Title: Plan Check #: Project Address: This Statement of Special Inspections is submitted in fulfillment of the requirements of the 2013 California Building

More information

Structural safety requirements of the Building Standard Law (BSL) of Japan and its enforcement system. IRCC Workshop Malmö

Structural safety requirements of the Building Standard Law (BSL) of Japan and its enforcement system. IRCC Workshop Malmö 国土技術政策総合研究所 National Institute for Land and Infrastructure Management Structural safety requirements of the Building Standard Law (BSL) of Japan and its enforcement system IRCC Workshop Malmö Wataru GOJO

More information

7. MATERIALS AND TECHNICAL INVESTIGATION

7. MATERIALS AND TECHNICAL INVESTIGATION 67 7. MATERIALS AND TECHNICAL INVESTIGATION Materials were chosen to provide minimal long-term maintenance. Hardwearing materials on ground floor levels were chosen to withstand the wear and tear of children

More information

Structural Redesign Gravity System

Structural Redesign Gravity System Redesign Gravity System Design Considerations A composite floor system was used for this design to maximize the efficiency of the material being used. This type of system requires less material and provides

More information

AN ASSESSMENT OF SAFETY OF A REAL SIX STORIED R.C.C FRAME STRUCTURE BY NON LINEAR STATIC PUSHOVER ANALYSIS

AN ASSESSMENT OF SAFETY OF A REAL SIX STORIED R.C.C FRAME STRUCTURE BY NON LINEAR STATIC PUSHOVER ANALYSIS Proceedings of the 3 rd International Conference on Civil Engineering for Sustainable Development (ICCESD 2016), 12~14 February 2016, KUET, Khulna, Bangladesh (ISBN: 978-984-34-0265-3) AN ASSESSMENT OF

More information

THE WALT DISNEY FAMILY MUSEUM

THE WALT DISNEY FAMILY MUSEUM THE WALT DISNEY FAMILY MUSEUM SUMMARY The Walt Disney Family Museum brings new life to three buildings in the, a National Historic Landmark District. This 77,000 sf rehabilitation project establishes a

More information

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone:

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone: 2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA 94070 Phone: 650-802-4261 PURPOSE: The residential provisions of the 2016 CalGreen

More information

THE PLAZA AT PPL CENTER ALLENTOWN, PA

THE PLAZA AT PPL CENTER ALLENTOWN, PA Building Function and Primary Use The owner of the new Plaza at PPL Center is Liberty Property Trust, but the primary tenant is PPL, which will use the building as the headquarters for its new subsidiaries

More information

B. Modular House. Feature: Installation Procedure:

B. Modular House. Feature: Installation Procedure: B. Modular House Feature: All manufacturing work and decoration are finished at factory, the onsite work is to install the modules and connect the municipal pipe network. The Wallboard is sandwich panel

More information

1 AND 2 FAMILY DWELLING REQUIREMENTS

1 AND 2 FAMILY DWELLING REQUIREMENTS PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans

More information

DEFINITIONS AND GENERAL EQUIREMENTS

DEFINITIONS AND GENERAL EQUIREMENTS DEFINITIONS AND GENERAL EQUIREMENTS 1.1 INTRODUCTION 1.1.1 SCOPE The definitions providing meanings of different terms and general requirements for the structural design of buildings, structures, and components

More information

NatureScape. 3 Thermally Broken 2 Non-thermal

NatureScape. 3 Thermally Broken 2 Non-thermal NatureScape 3 Thermally Broken 2 Non-thermal REASONS TO CONSIDER PREFABRICATED: Pre-designed, pre-engineered and pre-inspected, the NatureScape enclosure guarantees that the room will be delivered and

More information

CE 3150 Reinforced Concrete Design Design Project

CE 3150 Reinforced Concrete Design Design Project Problem Description For this design project you will work in your project groups to complete a partial design of an office building. Specifically, you will design and fully detail three components: 1.

More information