For Practice Only. Civil Engineering & Architecture Final Examination. Part C College Credit Performance. Fall/Winter Student Name: Date:
|
|
- Jessica Reynolds
- 6 years ago
- Views:
Transcription
1 Civil Engineering & Architecture Final Examination Part C College Credit Performance Fall/Winter Student Name: Date: Class Period: Total Points: /50 Copyright Page- 1 -
2 STAIRWELL OPENING Directions: Read each of the following problems and respond as requested. Show all work. Include proper units in all calculations. 1) Structural Analysis (10 Points Total) Answer the following questions based on the floor plan and data provided. Show all work. GIRDERS PARTIAL 2 nd FLOOR PLAN BEAMS Design data F y =50,000 psi (Steel) Dead Load =55 psf Live Load 80 psf (Office building - 2 nd Floor corridor-) Assume the weight of the floor beams and girders are included in the Dead Load above. a) Calculate the beam loading, using the beam that carries the greatest load. [4 points] Copyright Page- 2 -
3 b) Calculate End Reactions and Moment for the beam selected in Part a). [4 points] Reaction [2 points] Maximum Moment [2 points] Show all work c) Identify which Girder carries the greatest load. Explain how you determined this. [2 points] Copyright Page- 3 -
4 2) In the following picture, identify 4 structural components of the building and list them in the lettered spaces below. Label the 4 components on the drawing by using an arrow and the letter that correspond to the component name. (4 Points Total): ½ point for each component identified, ½ point for each correct label on drawing. Note: A crane is shown in front of the building. Structural Components Listed & Labeled with arrows A) B) C) D) Copyright Page- 4 -
5 3) Determine Footing Size (8 Points Total) Calculate the Minimum Square footing size for the given column loads. Size the footing to the nearest 6 inches (e.g. 1-6 x 1-6 ) DL + LL SHOW ALL OF YOUR WORK. Dead Load= 64,000 lbs Live Load =75,000 lbs Column W14 X53 Column Height 10 feet Assume thickness of footing 16 Weight of Concrete 150 lb/ft 3 Allowable Soil Bearing Capacity = 3,000 lb/ft 2 Include both the weight of the column and the weight of the footing in your calculations. Copyright Page- 5 -
6 4) Architectural Options (4 Points Total) A client would like you to design a vacation home in an exclusive ocean resort community. As the architect, you are trying to explain to the client the architectural characteristics that you have selected for the one-story structure. Give 2 factors that helped you decide the architectural style of the building. a. [2 points] b. [2 points] 5) Calculate the closure error for the differential survey notes below. (8 Points Total: 1 point for each correct HI and 1 point for correct elevation, 2 points for correct closure error). Point BS HI FS ELEV BM 5.26 ft ft TP ft 1.76 ft TP ft ft BM Closure Error: 8.04 ft Copyright Page- 6 -
7 6) A business s water supply connection at the street is at elevation 257 feet. The elevation of the first floor is 281 feet and a first floor fixture elevation is 285 feet. Between the connection and a first floor fixture, there are 150 feet of 2 inch copper pipe, 75 feet of ¾ copper pipe and five (5) ¾ - 90 o elbows. Discharge through the fixture is 15 gpm. The equivalent length for a single ¾, 90 o elbow is 4 feet. The Hazen-Williams constant for copper pipe is 140. SHOW ALL WORK a.) What is the head loss (in feet) due to friction and minor losses between the street connection and the first floor fixture? (8 Points Total) Copyright Page- 7 -
8 7) Your client has purchased a 10-acre abandoned mall parking lot in western New York, for development of a subdivision of single-family houses. The soil on this flat property is a well-drained, sandy loam. Estimate the runoff (cfs) under pre and postdevelopment (redevelopment) site conditions for the 10-year, 24-hour rainfall. See attached table and figure for additional information. Show all work in the space below. (8 Points Total): 2 points for correct pre/post development rainfall intensity, 2 points for correct pre/post development C- value, 2 points for correct pre/post development runoff, 2 points for correct pre/post-development runoff). Copyright Page- 8 -
9 Source: United States Department of Agriculture, Natural Resources Conservation Service, Technical Release-55. Copyright Page- 9 -
10 Rational Method Runoff Coefficients Categorized by surface Forested Asphalt Brick Concrete Shingle roof Lawns, well drained (sandy soil) Up to 2% slope % to 7% slope Over 7% slope Lawns, poor drainage (clay soil) Up to 2% slope % to 7% slope Over 7% slope Driveways, walkways Categorized by use Farmland Pasture Unimproved Parks Cemeteries Railroad yard Playgrounds (except asphalt or concrete) Business districts Neighborhood City (downtown) Residential Single family Multi-plexes, detached Multi-plexes, attached Suburban Apartments, condominiums Industrial Light Heavy Source: Lindeburg, M. R. (1994). Civil engineering reference manual (6 th ed.). pp Belmont, CA: Professional Publications, Inc. Copyright Page- 10 -
Activity Calculating Property Drainage
Page 1 of 5 Activity 2.3.11 Calculating Property Drainage Introduction When a property is developed, it is important to understand that changes to watershed characteristics (i.e., land use, slope, soil
More informationCivil Engineering & Architecture Final Examination. Parts A, B & C ANSWER KEY
Civil Engineering & Architecture Final Examination Parts A, B & C ANSWER KEY Spring 2009 PRACTICE EXAM For Teacher Use ONLY Copyright 2005 - Page- 1 - Part A Multiple Choice Questions Question Answer CEA
More informationTechnical Report #1. Indiana Regional Medical Center Indiana, PA. Cody A. Scheller. Structural Concepts & Existing Conditions Report
Technical Report #1 Technical Report #1 Structural Concepts & Existing Conditions Report Indiana Regional Medical Center Cody A. Scheller The Pennsylvania State University Architectural Engineering Faculty
More informationAPPENDIX F RATIONAL METHOD
7-F-1 APPENDIX F RATIONAL METHOD 1.0 Introduction One of the most commonly used procedures for calculating peak flows from small drainages less than 200 acres is the Rational Method. This method is most
More informationRunoff Calculations. Time of Concentration (T c or t c ) from one location to another within a watershed. Travel
Runoff Calculations Bob Pitt University of Alabama and Shirley Clark Penn State Harrisburg Time of Concentration and Travel Time (based on Chapter 3 of TR-55) Time of Concentration (T c ): time required
More informationAPPENDIX E APPENDIX E ESTIMATING RUNOFF FOR SMALL WATERSHEDS
APPENDIX E ESTIMATING RUNOFF FOR SMALL WATERSHEDS March 18, 2003 This page left blank intentionally. March 18, 2003 TABLES Table E.1 Table E.2 Return Frequencies for Roadway Drainage Design Rational Method
More informationAPPENDIX E ESTIMATING RUNOFF FROM SMALL WATERSHEDS
ESTIMATING RUNOFF FROM SMALL WATERSHEDS June 2011 THIS PAGE LEFT BLANK INTENTIONALLY. June 2011 TABLES Table E.1 Table E.2 Return Frequencies for Roadway Drainage Design Rational Method Values June 2011
More informationEarth and Engineering Sciences Building University Park, Pennsylvania
Executive Summary The Earth and Engineering Sciences building is a 4 story educational and laboratory facility. An additional basement level is located below grade and provides the foundation for the East
More informationNames: ESS 315. Lab #6, Floods and Runoff Part I Flood frequency
Names: ESS 315 Lab #6, Floods and Runoff Part I Flood frequency A flood is any relatively high flow of water over land that is not normally under water. Floods occur at streams and rivers but can also
More informationLAKE COUNTY HYDROLOGY DESIGN STANDARDS
LAKE COUNTY HYDROLOGY DESIGN STANDARDS Lake County Department of Public Works Water Resources Division 255 N. Forbes Street Lakeport, CA 95453 (707)263-2341 Adopted June 22, 1999 These Standards provide
More informationDead Loads (psf): Concrete Floor Slab on Metal Deck 45 psf Mechanical and Ceiling 7 psf Miscellaneous 5 psf Exterior Wall 80 psf
CODES AND REQUIREMENTS The structural design of Northbrook Corporate Center was based on the International Building Code 2003, which incorporates many of the provisions of ASCE 7. The lateral load design
More informationSuspended Metal lath and Cement Plaster. Coverings Rigid Insulation, 1/2 - in 0.75 psf. Floor Fill Lightweight Concrete, per inch 8 psf
Dead Loads Ceiling Suspended Metal lath and Cement Plaster 15 psf Coverings Rigid Insulation, 1/2 - in 0.75 psf Floor Fill Lightweight Concrete, per inch 8 psf Floor Finish Frame Partitions Ceramic or
More informationSump Pumps Office procedures for the Drainage & Grading section
County of Los Angeles Department of Public Works Building and Safety Division Grading and Drainage Section Sump Pumps Office procedures for the Drainage & Grading section Introduction This manual provides
More informationCity of Redwood City Stormwater Pollution Prevention Program. Drainage Guidelines for Residential Development
City of Redwood City Stormwater Pollution Prevention Program Drainage Guidelines for Residential Development General Requirements A. Plot & Finished Grading Plan must be submitted with Building Permit
More informationStructural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B
Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Executive Summary The proposed thesis will include an investigation of two different alternative structural
More informationErie on the Park. Timothy Moore Penn State University Architectural Engineering Structural Emphasis Advisor: Prof. Ali Memari
Timothy Moore Penn State University Architectural Engineering Structural Emphasis Advisor: Prof. Ali Memari Thesis Presentation - Spring 2006 Contents Introduction Building Professionals Existing Structure
More informationOVERALL STRUCTURAL SYSTEM
EXECUTIVE SUMMARY The at the Pittsburgh International Airport, PA, is a 275,000 square foot multi-use building located directly adjacent to the airport s landside terminal. The building consists of an
More informationKeywords: Discrete Staggered Shear Wall, High-Rise Building, Response Spectrum Analysis, Storey Drift.
www.semargroup.org, www.ijsetr.com ISSN 2319-8885 Vol.03,Issue.09 May-2014, Pages:1830-1835 Seismic Response of High-Rise Structure with Staggered Shear Wall AUNG MON 1, TIN TIN HTWE 2 1 Dept of Civil
More information[TECHNICAL REPORT 3] Lateral System Analysis
Science Center Research Park 3711 Market St. The Pennsylvania State University Department of Architectural Engineering Senior Thesis 2009-2010 Prepared by: November 30, 2009 [TECHNICAL REPORT 3] Lateral
More informationTable of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5
WISCONSIN PLACE RESIDENTIAL TECHNICAL ASSIGNMENT 1 OCTOBER 5, 2007 KURT KRASAVAGE THE PENNSYLVANIA STATE UNIVERSITY STRUCTURAL OPTION FACULTY ADVISOR: DR. ALI MEMARI Table of Contents Table of Contents
More informationCommercial Remodel Permit
Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each
More informationMINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS
Planning and Community Preservation Department Public Works Department 232 West Sierra Madre Boulevard Sierra Madre, CA 91024 (626)355-7135 MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE
More informationCOMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS
COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS BUILDING & SAFETY DIVISION (530) 795-4910 ext. 112 or 117 FAX (530) 795-4935 318 First Street Winters, CA 95694 This is a list of the minimum
More informationAppendix J: Storm Conveyance Design Parameters
Appendix J: Storm Conveyance Design Parameters Drain Commissioner 39 February 2005 STORM DRAINAGE DESIGN CRITERIA A. STORM SEWERS 1. The required discharge capacity shall be determined by the Rational
More information111 MORGAN ST. Ryan Friis
Technical Report No. 1 September 30, 2002 Executive Summary: 111 Morgan St. is a 9 story cast-in-place concrete condominium building being constructed in Chicago, Illinois. The building s floor system
More informationRESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS
RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS DATE: October 17, 2000 RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS INTRODUCTION These Residential Design Guidelines have been approved by
More informationSimplified Building Schematic for Typical Floor (Levels 9 through 22):
Introduction to Structural System Simplified Building Schematic for Typical Floor (Levels 9 through 22): Key: - Tower Columns - Tower Shear Walls - Parking Garage Columns - Parking Garage Shear Walls Solid
More information(b) Calculate the required nominal axial compression strength, Pn of the column.
9 Problem 2-3 (a) Determine the factored axial load or the required axial strength, Pu of a column in an office building with a regular roof configuration. The service axial loads on the column are as
More informationLateral System Analysis and Confirmation Design November 15, 2004
Jonathan Hill Structural AE Faculty Consultant Dr. Hanagan Lynde and Harry Bradley School of Technology & Trade Milwaukee, Wisconsin Lateral System Analysis and Confirmation Design November 15, 2004 Executive
More information1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)
1420 Miner Street Des Plaines, IL 60016 P: 847.391.5380 desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) Five sets of stamped plans and specifications (six sets if food establishment),
More informationSAMPLE DRAINAGE STATEMENT
Firm Name & Logo Hidalgo County Drainage District No. 1 Drainage Statement Subdivision Name Hidalgo County, Texas Prepared By: Firm's Name Address City, State, Zip Telephone Fax Email Date SAMPLE DRAINAGE
More informationCE 3150 Reinforced Concrete Design Design Project
Problem Description For this design project you will work in your project groups to complete a partial design of an office building. Specifically, you will design and fully detail three components: 1.
More informationCITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application
CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application DATE: / / PERMIT # REQUEST FOR: NEW BUILDING ADDITION REMODEL PLUMBING ONLY ELECTRIC ONLY
More informationPART V - STORM DRAIN DESIGN CRITERIA
PART V - STORM DRAIN DESIGN CRITERIA A. Hydrology Studies and Hydraulic Analyses 1. Drainage area master plans and calculations are to be submitted with all subdivision improvement plans, permit improvement
More informationPART V - STORM DRAIN DESIGN CRITERIA
PART V - STORM DRAIN DESIGN CRITERIA A. Hydrology Studies and Hydraulic Analyses 1. Drainage area master plans and calculations are to be submitted with all subdivision improvement plans, permit improvement
More informationGarage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements
General Information Site Card. Before starting construction, post the site card (issued by the City) in a front window visible from the street. Miss Dig. Before you dig, call Miss Dig at 800.482.7171 This
More informationLateral System Analysis and Confirmation Design
Andrew Covely Structural Dr. Linda Hanagan The Helena New York City, NY November 15, 2004 Pictures courtesy of Fox & Fowle Architects Lateral System Analysis and Confirmation Design Executive Summary This
More informationStructural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design
Fall Semester 2018 Preliminary Exam - Structural Design A small building is located in downtown Berkeley. The structural system, either structural steel or reinforced concrete, comprises gravity framing
More informationSection V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES
Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES A. GENERAL 1. The following water system design guidelines are based on Federal, State and local health requirements and the Hilton Head No. 1 Public
More informationMOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS
MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS PARKERSBURG, WEST VIRGINIA DOMINIC MANNO STRUCTURAL OPTION FACULTY CONSULTANT: DR. ANDRES LEPAGE Technical Report 3 11-21-08 TABLE OF CONTENTS TABLE OF
More informationLetter of Transmittal
Letter of Transmittal November 17, 2014 Ali Said Structural Thesis Advisor The Pennsylvania State University aus59@psu.edu Dear Doctor Said, The following technical report fulfills the fourth Technical
More informationWilliam W. Wilkins Professional Building Columbus, Ohio
William W. Wilkins Professional Building Columbus, Ohio Technical Assignment 1 October 5, 2006 Michelle Structural Option AE 481W Senior Thesis Faculty Advisor: Dr. Boothby Table of Contents Executive
More informationBUILDING DESCRIPTION
BUILDING DESCRIPTION ARCHITECTURAL ENGINEERING SENIOR THESIS 1 Building Description Location: The Residences of Sherman Plaza are located in the diverse community of downtown Evanston, IL, just north of
More informationFEE SCHEDULE 7 Water Development and Connection Fees Aurora Water (Platted Before January 1, 2017)
FEE SCHEDULE 7 Water Development and Connection s (Platted Before January 1, 2017) Connection s Connection s consist of three components: 1), 2) Sanitary Sewer Connection and 3) Metro Wastewater District
More informationIntroduction & Project Background
Introduction & Project Background Project Background is located in Pasadena, Maryland and is owned and maintained by Anne Arundel County School District. A new elementary school to replace the existing
More informationTwo complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.
The Homeowner s Building Application Checklist for Constructing a Residential Accessory Building This checklist provides homeowners a summary of the Building Permit submission requirements for constructing
More informationSimplified Building Schematic for Typical Floor (Levels 9 through 22):
Introduction to Structural System Simplified Building Schematic for Typical Floor (Levels 9 through 22): Key: - Tower Columns - Tower Shear Walls - Parking Garage Columns - Parking Garage Shear Walls Solid
More informationIntroduction to Storm Sewer Design
A SunCam online continuing education course Introduction to Storm Sewer Design by David F. Carter Introduction Storm sewer systems are vital in collection and conveyance of stormwater from the upstream
More informationProperty Insurance Association of Louisiana
Property Name: Location: Survey Date: Barksdale Federal Credit Union - Offices 2701 Village Ln, Bossier City, LA, 71112 April 23, 2018 All rights reserved. part of this publication may be reproduced, distributed,
More informationThird Avenue New York, NY. Structural Concepts/ Structural Existing Conditions Report September 30, Michelle L.
Executive Summary The structural design of 554-556 Third Avenue is composed of two way concrete slabs supported by a system of columns spanning an average of twenty feet. Lateral loads are resisted by
More informationHilton Baltimore Convention Center Hotel Western Podium
Hilton Baltimore Convention Center Hotel Western Podium CHRIS SIMMONS Structural Option Faculty Consultant: Dr. Ali M. Memari Technical Report 2 TABLE OF CONTENTS EXECUTIVE SUMMARY. Page 3 INTRODUCTION..
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationCITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements
CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY
More informationResidential Patio Cover Specifications
Residential Patio Cover Specifications This information bulletin describes the minimum requirements for obtaining patio cover permits for residential buildings using the City of Vista standard plan or
More information20 North Main Alpine, UT (Phone) (Fax) SITE PLAN
Site Plan Instructions New Home Form #1 20 North Main Alpine, UT 84004 801-756-6347 (Phone) 801-756-1189 (Fax) www.alpinecity.org SITE PLAN A detailed site plan, drawn to scale, 1 = 20 min., shall be filed
More informationSouthwest Housing, Arizona State University
Prepared by KSENIA TRETIAKOVA Structural Option 01.09.2012 Architectural Engineering Pennsylvania State University 2012 Southwest Housing, Arizona State University Technical Report #3 Lateral System 01.09.2012
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationThe Pennsylvania State University Department of Architectural Engineering Senior Thesis. Ryan Pletz Structural Dr. Hanagan.
The Pennsylvania State University Department of Architectural Engineering Senior Thesis Ryan Pletz Structural Dr. Hanagan April 14, 2008 Project Team Owner: Prince William County Schools Architect: Jim
More informationContinuing Education Course #209 Green Irrigation Fundamentals Balancing Aquifer Recharge and Withdrawal
1 of 7 Continuing Education Course #209 Green Irrigation Fundamentals Balancing Aquifer Recharge and Withdrawal 1. The balanced irrigation water demand is based mainly on (hint: water created by the improvements):
More informationDESIGN GUIDELINES FOR MULTI FAMILY AND ATTACHED SINGLE FAMILY INFILL HOUSING
DESIGN GUIDELINES FOR MULTI FAMILY AND ATTACHED SINGLE FAMILY INFILL HOUSING Multi family housing is an increasingly popular form of infill development in Shaker Heights because of the city s built out
More informationHOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013
HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013 HOTEL N.E.U.S. BUILDING INFORMATION SITE Located in the Northeast United States
More informationACCESSORY BUILDING. Building Permit Requirements: (must be completed before submitting application)
ACCESSORY BUILDING Before your application can be deemed complete and ready for processing you will need the following: (Please hand in entire application package including this cover sheet) Zoning- check
More informationCity of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)
City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,
More informationARTICLE 13 SITE PLAN REVIEW
Sections: 13-1 Intent 13-2 Applicability 13-3 Authority 13-4 Filing Fee 13-5 Submission Requirements 13-6 Standard of Review 13-7 Development Standards ARTICLE 13 SITE PLAN REVIEW SECTION 13-1 INTENT 13-101.
More informationLEARNING OF ETABS. 15 ft
LEARNING OF ETABS Ram Krishna Mazumder, Institute of Earthquake Engineering Research, Chittagong University of Engineering and Technology, Chittagong 4349, Bangladesh rkmazumder@gmail.com +8801712862281
More informationRESIDENTIAL DISTRICT (R)
ARTICLE 12 RESIDENTIAL DISTRICT (R) Sections: 12-1 Application/Purpose 12-2 Permitted Uses 12-3 Conditional Uses 12-4 Development Standards 12-5 Parking Regulations 12-6 Sign Regulations 12-7 Height, Area,
More informationLighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: Office@LighthouseEng.com Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
More informationStructural Option Indiana Regional Medical Center Indiana, PA
West View of IRMC Southeast View of IRMC Structural Option Indiana Regional Medical Center Indiana, PA West View of IRMC Southeast View of IRMC Arial View of IRMC Project Information N Location: Occupancy
More informationNeighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations
Section 16.20.020 - Neighborhood Suburban Single-Family Districts ( NS ) Sections: Typical Block in a Neighborhood Suburban District 16.20.020.1 History and Composition of Suburban Neighborhoods 16.20.020.2
More informationFire Resistive Design of Exposed Timber Structures
Fire Resistive Design of Exposed Timber Structures Heavy Timber & One Hour Fire Rating Paul C. Gilham, P.E., S.E. Western Wood Structures, Inc. The Wood Products Council is a Registered Provider with The$
More informationGRAYWATER STANDARD PLAN For Simple Residential System
(Based on 203 California Plumbing Code Chapter 6) Project Address: Permit Number: Scope: This Plan applies only to simple residential systems meeting all the following criteria: Graywater discharge is
More informationRutgers University Law School Building Addition and Renovation Camden, NJ
Building Addition and Renovation Camden, NJ Technical Assignment 1 October 5, 2007 Nathan E. Reynolds Structural Option Senior Thesis The Pennsylvania State University Faculty Consultant: Professor M.
More informationPART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS
PART 3 - STANDARDS FOR SEWERAGE FACILITIES 3.3 - DESIGN OF STORM SEWERS 3.301 Design of Storm Sewers A. General Information B. Investigations and Surveys C. Special Projects 3.302 Design Criteria for Storm
More informationStructural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/
120 Montgomery Street, Suite 1410 San Francisco, California 94104 415/781-1505 Fax 415/781-2718 sde@sdesf.com Rajendra Sahai, SE Principal John W. Laws, SE Principal Steven Lepisto, SE Principal STRUCTURAL
More informationENGINEERING REVIEW CHECKLIST City of Mount Clemens
(To be completed by the Developer s & Submitted with ing Plans) DATE: PROJECT NAME: Site Plan Approved: Date DESIGN ENGINEERING COMPANY: ing Company Contact Information: Name: Phone: Email: Owner Contact
More informationLDR RESIDENTIAL LAND DEVELOPMENT REGULATIONS (LDRs) CODE UPDATE C.O.W. January 19, 2017
LDR 2017-01 RESIDENTIAL LAND DEVELOPMENT REGULATIONS (LDRs) CODE UPDATE C.O.W. January 19, 2017 SECTION NO. SECTION TITLE COMPLEXITY DESCRIPTION 1. 16.20.010.5. Maximum development potential Problem Statement:
More informationHYDROLOGY STUDY LA MIRADA BOULEVARD La Mirada, California
HYDROLOGY STUDY 12000 LA MIRADA BOULEVARD La Mirada, California TTM 73119 Prepared for: The Olson Company 3010 Old Ranch Parkway, Suite 100 Seal Beach, CA 90740 Contact: Mr. Aaron Orenstein (562) 370-9531
More informationEngineering Division 701 Laurel Street Menlo Park, CA Phone: (650) Fax: (650)
Engineering Division 701 Laurel Street Menlo Park, CA 94025 Phone: (650) 330-6740 Fax: (650) 327-5497 GRADING AND DRAINAGE GUIDELINES FOR SINGLE FAMILY HOME PROJECTS It is the responsibility of the property
More information80 Fy (ksi)= 50 2 nd Floor = 61. Length (ft) Plan View. Penthouse
SUBJECT: CORNER SHEET 62 of 131 Design Columns for the lightest W10's and W12's section. Columns are to be sized for two options: Option I Continuous, Option II with Splices. Then prices are to be compared
More informationEAGLE DRAINAGE DESIGN STANDARDS
EAGLE DRAINAGE DESIGN STANDARDS November 17, 2015 City of Eagle Planning & Zoning Department P.O. Box 1520 Eagle, ID 83616 EAGLE DRAINAGE DESIGN STANDARDS A. PURPOSE 1. These standards amend the Design
More informationTOWN OF EASTCHESTER BUILDING & PLANNING DEPARTMENT BUILDING PERMIT APPLICATION PACKAGE
TOWN OF EASTCHESTER BUILDING & PLANNING DEPARTMENT 40 Mill Road Phone: (914) 771-3317 building@eastchester.org Eastchester, NY 10709 Fax: (914) 771-3322 www.eastchester.org BUILDING PERMIT APPLICATION
More informationTOWN OF EASTCHESTER BUILDING & PLANNING DEPARTMENT BUILDING PERMIT APPLICATION PACKAGE
TOWN OF EASTCHESTER BUILDING & PLANNING DEPARTMENT 40 Mill Road Phone: (914) 771-3317 building@eastchester.org Eastchester, NY 10709 Fax: (914) 771-3322 www.eastchester.org BUILDING PERMIT APPLICATION
More informationCivil Engineering and Architecture TEKS/LINKS Student Objectives One Credit
First Six Weeks History of Civil Architect CEA 1.1(A) The student will connect modern structural and architectural designs to historical architectural and civil engineering achievements. CEA 1.1(B) The
More informationStructural Tech Report #2 Pro Con Structural Study of Alternate Floor Systems
Structural Tech Report #2 Pro Con Structural Study of Alternate Floor Systems Table of Contents 1. Executive Summary.....Page 2 2. Existing Floor System....Page 4 2.1. Composite steel beams with composite
More informationPRELIMINARY DRAINAGE STUDY
PRELIMINARY DRAINAGE STUDY For 34 th & J Residences 3402 J St. San Diego, CA 92102 A.P.N 545-250-08 Prepared By: Kenneth J. Discenza, P.E. Site Design Associates, Inc. 1016 Broadway, Suite A El Cajon,
More informationMASONRY, ARCHITECTURE DESIGN AND BUILDING STANDARDS
MASONRY, ARCHITECTURE DESIGN AND BUILDING STANDARDS 4.5500 RESERVED 4.5501 MASONRY STANDARDS FOR CENTRAL BUSINESS DISTRICT (CBD) a) All buildings and structures shall be of exterior fire resistant construction,
More informationRiver Valley Village Overall Development Plan/Conceptual Site Plan Amendment
River Valley Village Overall Development Plan/Conceptual Site Plan Amendment 2 100416 Contents 1.0 General Standards 1.1 Community Vision 1 (a) Design Inspiration 1 (b) Design Intent 2 (c) Standards Application
More informationCITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures
CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person
More informationPro-Con Structural Study of Alternate Floor Systems
Andrew Covely Structural Dr. Linda Hanagan The Helena New York City, NY October 27, 2004 Pictures courtesy of Fox & Fowle Architects Pro-Con Structural Study of Alternate Floor Systems Executive Summary
More informationVARIOUS TYPES OF SLABS
VARIOUS TYPES OF SLABS 1 CHOICE OF TYPE OF SLAB FLOOR The choice of type of slab for a particular floor depends on many factors. Economy of construction is obviously an important consideration, but this
More informationJanuary 21, 2014 File No. 12-12046 Mark Antunes, Technical Information Manager E.P. Henry Corporation 16 Anderson Road Parker Ford, PA 19457 Reference: Permeable Paver Infiltration Testing Eco Brick Stone
More informationTable of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8
WISCONSIN PLACE RESIDENTIAL TECHNICAL ASSIGNMENT 2 OCTOBER 29, 2007 KURT KRASAVAGE THE PENNSYLVANIA STATE UNIVERSITY STRUCTURAL OPTION FACULTY ADVISOR: DR. ALI MEMARI 1 Table of Contents Table of Contents.2
More informationResidential Design Standards Draft 9 August 2013
RESIDENTIAL DESIGN STANDARDS ORDINANCE DRAFT 9 AUGUST 2013 17.25 Residential Design Standards 17.25.010 Purpose The purpose of this chapter is to establish minimum design standards for new residential
More informationSection 600 Runoff Table of Contents
Section 600 Runoff Table of Contents 601 INTRODUCTION...600-1 602 RATIONAL METHOD...600-1 602.1 Rational Method Formula...600-2 602.2 Time of Concentration...600-2 602.3 Intensity...600-4 602.4 Runoff
More informationEASTERN SE & 750 CHERRY SE - REQUEST FOR NEW BUILDINGS
Planning Staff Report Meeting Date: November 1, 2017 215-255 EASTERN SE & 750 CHERRY SE - REQUEST FOR NEW BUILDINGS BACKGROUND: The project in question is in regards to two new buildings previously approved
More informationCity of Lorena 107-A S. Frontage Road Lorena, Texas Phone: (254) Fax: (254)
Residential New Home Building Requirements This document is not meant to modify any Federal or State laws or City Ordinances. It is intended to be informative and to be used as a guideline. Where circumstances
More informationTOWN OF LINCOLN MINUTES OF THE PLANNING BOARD MARCH 22, 2016 TOWN OFFICES
TOWN OF LINCOLN MINUTES OF THE PLANNING BOARD MARCH 22, 2016 TOWN OFFICES PRESENT: Margaret Olson (Chair)(MO), Bryce Wolf (Co-Chair)(BW), Gary Taylor (GT) STAFF: Paula Vaughn-MacKenzie 7:00 PM PUBLIC HEARING,
More informationCITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING
CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING See Setback/Coverage Worksheet & Criteria: Pages 1-4 & Accessory Structure Guide Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
More informationHIGH RISE CONDO SOHO, NEW YORK, NY
HIGH RISE CONDO SOHO, NEW YORK, NY TECHNICAL ASSIGNMENT 1 October 5, 2006 Joseph The Pennsylvania State University Structural Option Faculty Advisor: Andres Lepage TABLE OF CONTENTS TABLE OF CONTENTS 2
More informationCity of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)
City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,
More information