ACCESSORIES ROTOTEC ACCESSORIES

Size: px
Start display at page:

Download "ACCESSORIES ROTOTEC ACCESSORIES"

Transcription

1 ACCESSORIES ACCESSORIES ROTOTEC

2 ACCESSORIES ROTOTEC 137

3 H H ACCESSORIES Ø Cover THREADED EXTENSION Ø H Ø Cover PP PP PP Ø Application: Installing the extensions enables the tops of the tanks to be installed below ground level. More than one extension can be used at the same time (See chapter on Underground installation). Ø Cover HINGED TOP EXTENSION Ø H Ø Cover PP PP Application: Installing the extensions enables the tops of the tanks to be installed below ground level. More than one extension can be used at the same time (See chapter on Underground installation). Ø é nal THREADED COVER IN PP WITH VENT* é nal HINGED COVER IN PE CS TAP 700* CS TAP 710* CS *supplied with above-ground tanks *Green colour available on request é nal THREADED COVER IN PP* COVER GASKET Cover model CC GC CC CS CC GC CC CS CC GC CC CS CC CC é GC CC Material: NBR rubber * supplied with treatment tanks 138 ACCESSORIES ROTOTEC

4 RING Ø AF AF AF AF AF H ring Application: Installed when creating customised inspection holes. GASKET cutter Ø for gasket hole GG GG GG GG GG GG GG 125 S GG GG GG Application: for the installation of inlet and outlet pipes on a tank; guarantees a hydraulic seal. D OUTET PIPE UNION IN BRASS Ø Int. Ø Ext. D inches BSO ¾ ¾ '' BSO '' BSO 1 ¼ ''¼ BSO 1 ½ ''½ BSO '' BSO 2 ½ '' ½ BSO '' BSO '' Application: When installed on it allows the storage tank to be connected to the various draw-off systems for the liquid it contains: systems... It also allows the tanks to be connected to each other (both underground and above-ground tanks) so as to give very high storage volumes. D OUTET PIPE UNION IN POYPROPYENE M M inches H D BS ¾ ¾ BS BSO1,5 1 ½ BS BS2 ½ 2 ½ Application: When installed on it allows the storage tank to be connected to the various irrigation allows the tanks to be connected to each other (both underground and above-ground tanks). ACCESSORIES ROTOTEC 139

5 ACCESSORIES DRAINAGE PIPES Description: Corrugated and perforated PE pipe used as dispersion pipes in subirrigation systems. Available in diameters AERATION SYSTEM FOR WATER STORAGE TANKS KIT AIR Aeration system consisting of: - QST timed electric panel - Blower model HP 40 - Diffuser plates model IFA DN - Connecting pipes - Cabinet excluded Application: A system for installation in rainwater or treated water storage tanks. Used for blowing clean air from the bottom of the tank in order to agitate and intervals. SAFETY GRI é Ø grill Mesh length Mesh width GRANT Application: The pedestrian grill is a safety device that prevents unintentional entry into the tank. Installation: the pins provided. It can be mounted directly on the tank manhole or on a hinged cover extension (model PP75). EECTRIC FOAT Float dimensions Cable length Amps A Voltage V Protection grade Max. temperature C GA 5 80x100x (4) 250 IP Application: Float level switch for fresh water pump start/stop. 140 ACCESSORIES ROTOTEC

6 PE FANGED JOINT Thickness 1 Ø Flange 1 GF GF GF Ø Int. Ø Ext. Application: Allows the tanks to be connected together (underground or above ground) to obtain extremely large storage volumes. SINGE DOSE BIO-ACTIVATOR SACHETS Description Function: to speed up the activation time of biological processes that normally develop in waste water treatment plants. Dissolve in a bottle of warm water and pour directly into the WC or into the tanks. Weight g IFABIO Single dose activator sachet for biological septic tanks SPECIFIC CONCENTRATED BIO-ACTIVATOR Description Weight g IFABIODEG Bio-activator specific for activation of grease separators IFABIOAN IFABIOIFA Bio-activator specific for activation of anaerobic treatment plants (septic or Imhoff tanks, anaerobic trickling filters,...) Bio-activator specific for activation of aerobic treatment plants (activated sludge system, aerobic trickling filters,...) Function: develop in waste water treatment plants. Dissolve in a bottle of warm water and activation of the various tanks making up a treatment system. ACCESSORIES ROTOTEC 141

7 ACCESSORIES EECTROWEDABE PE SEEVE PN10 FOAT VAVE MAN MAN MAN RAG FITER BASKET EXTERNA EVE INDICATOR CF I Application: spare part for POYPROPYENE EXTENSION PE PIPE PN10 PM20X20G 9.00 PM20X20V PM30X30G PM30X30V PIPE PIPE PIPE Application: extension to be installed on the grease separators with separation 142 ACCESSORIES ROTOTEC

8 NOTES ACCESSORIES ROTOTEC 143

InnoClean PLUS Wastewater Treatment Systems

InnoClean PLUS Wastewater Treatment Systems InnoClean PLUS Wastewater Treatment Systems Fully biologic SR wastewater treatment systems according to Euronorm EN 12566Part 3 Leading in drainage InnoClean PLUS the natural alternative The InnoClean

More information

Wastewater treatment for single houses. D. O Dowd

Wastewater treatment for single houses. D. O Dowd Wastewater treatment for single houses 1 * In rural settings, connection to the local authority main sewer is not always possible, so each house has its own separate wastewater treatment system for the

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against

More information

Aqua-Recycling-Control 80B Plus

Aqua-Recycling-Control 80B Plus Aqua-Recycling-Control 80B Plus Item No G17200, G17205 Example picture, Aqua-Recycling-Control including Aqua-Control (is not included in scope of supply) Typical applications - Decentralized waste water

More information

6 Wastewater. Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PLUS. for concrete tanks

6 Wastewater. Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PLUS. for concrete tanks InnoClean PUS Page 273 27 wastewater Small sewage treatment plants using the activated sludge principle (SR) Renovation/retrofit set and Page 280 OEM original equipment set InnoClean PUS for concrete tanks

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

GB-20. Submittal Specifications Installation Application Specific Details

GB-20. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL (53.3 cm) STANDARD: 2" plain end

More information

REFLECTION ISF INFORMATION RWTS.CO.NZ. Pure. Wastewater. Solutions.

REFLECTION ISF INFORMATION RWTS.CO.NZ. Pure. Wastewater. Solutions. REFLECTION ISF INFORMATION RWTS.CO.NZ Pure. Wastewater. Solutions. WITH MORE THAN 3000 WASTEWATER SYSTEMS TREATING IN EXCESS OF 2.5 MILLION LITRES OF WASTEWATER EVERY DAY THROUGHOUT THE REGION, OUR TRACK

More information

t y p e V S A S E W A G E P U M P

t y p e V S A S E W A G E P U M P Pe r fo r m a n ce C h a r t 65 6 55 45 4 35 3 25 2 12 11 1 / 2 11 1 1 / 2 1 9 1 / 2 6% 7% 76% 7 1 HP 1/2 HP HP 76% 7% 6% C u r v e P a g e V S A - 5 1 1 5 R P M M O D E L : V S A - 6 H D I S C H A R G

More information

VALVES. Prospector Series Poppet Valves 1/4" to 2" Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves

VALVES. Prospector Series Poppet Valves 1/4 to 2 Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves 2 High flow - Cv of 1.2 to 49.5 Durable, robust construction Two mounting styles: inline or subbase 1/4" to 2" ports (SPP or PTF threads) Wide range of ir Pilot Operators available Four functional types:

More information

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm

E 444 E 454 E 464 E 644 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 680 l/min / gpm Return Filters E E 5 E 6 E 6 Tank top mounting Connection up to SAE Nominal flow rate up to 68 l/min / 79.7 gpm Description Application In the return line circuits of hydraulic systems. erformance features

More information

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS KEMDRAIN TM STAINLESS INDUSTRIAL FLOOR DRAINS AND LINEAR CHANNELS, OFFERING ALL THE BENEFITS OF 316L

More information

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH SYSTEM FOR THE EXPLOITATION OF RAINWATER AQUAPROF TOP ACTIVE SWITCH AQUAPROF BASIC / AQUAPROF TOP AQUAPROF TOP Applications The AQUAPROF unit is used for the management

More information

UNI EN CERTIFIED Domestic Sewage Treatment Plant

UNI EN CERTIFIED Domestic Sewage Treatment Plant UNI EN12566-3 CERTIFIED Domestic Sewage Treatment Plant 1. Introduction 2. Standard UNI EN 12566-3 3. Operating principles 4. Technical data 5. DEPURO PLUS 6. Installation 7. Use and maintenance 8. Conformity

More information

POLYDOX 30. instruction manual

POLYDOX 30. instruction manual POLYDOX 30 instruction manual Table of contents 1.) Producer: Polyduct ZRT. 2.) Standard No.: EN 12 566-3 3.) Characteristics 4.) Terms of use 4.1. Construction of POLYDOX Waste water treatment plant 4.1.1.

More information

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name AT-GRADE MOUND SEWAGE DISPOSAL SYSTEM INSPECTION CHECKLIST I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name B. MDE Certified Installer Present for entire

More information

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact

More information

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

Floor drain armatures

Floor drain armatures Floor drain armatures Floor drain armatures Concrete or liner pools can be easily emptied via OASE floor drains. The drains are available with plug or with sieve. The concrete part is the basis of every

More information

WHAT TO CONSIDER IN CHOOSING A SYSTEM

WHAT TO CONSIDER IN CHOOSING A SYSTEM WHAT TO CONSIDER IN CHOOSING A SYSTEM Reflections Comparison Price Include engineering Plan & Report for local council Include excavation and installation of: - Septic Tank - Treatment Plant - Irrigation

More information

Installation and operation instructions

Installation and operation instructions PURAIN-HD-150/200/300/400 Rainwater filter for sub-surface installation Heavy duty category Installation and operation instructions WATER IS OUR ELEMENT www.intewa.com Contents 1. Introduction and scope

More information

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units Clarus Environmental Overview Clarus Environmental is a division of the Zoeller Company, an industry leader in pumps

More information

Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale , Kolhapur Dist. TENDER NO D5

Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale , Kolhapur Dist. TENDER NO D5 ICHALKARANJI POWERLOOM MEGA CLUSTER LTD., ICHALKARANJI. TAL- HATKANANGLE, DIST- KOLHAPUR. Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale 416 109, Kolhapur Dist. Website www. ichmegacluster.com

More information

Arms Group Drainage System. 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve

Arms Group Drainage System. 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve Arms Group Drainage System 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve Swivel Joint Type Model No. 1010 Sizes 3in through 8in Heavy

More information

DEPURO CERTIFIED PLANTS FOR WASTEWATER TREATMENT UNI EN ROTOTEC - Depuro

DEPURO CERTIFIED PLANTS FOR WASTEWATER TREATMENT UNI EN ROTOTEC - Depuro 1 DEPURO CERTIFIED PLANTS FOR WASTEWATER TREATMENT UNI EN 12566-3 June 2016 CERTIFIED WASTEWATER TREATMENT European standards and CE marking Standards are documents that determine the characteristics (dimensional,

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX offers a line of products designed specifically for solar heating, renewable energy sources used to produce hot water using solar energy. The product range consists

More information

On-lot System Component Requirements

On-lot System Component Requirements On-lot System Component Requirements All system components used with an on-lot system employing an Eljen GSF System must meet either the requirements of Title 25, Chapter 73 or the Eljen GSF Listing. The

More information

HAWLE-range of products

HAWLE-range of products HAWLE-pRODucTS All OvER ThE world since 1948 HAWLE-range of products HAWLE subsidiaries HAWLE partners Illustrations, technical data, dimensions and weights are subject to alteration without notice. Edition

More information

The Flat Rainwater Harvesting Tank

The Flat Rainwater Harvesting Tank The Flat Rainwater Harvesting Tank years warranty Awarded Design Complete systems for house and garden Applied for a patent Inspired by nature. Strong light weight and long-lasting. Program 08 / 09 Rainwater

More information

Water Cooled Oil Cooler

Water Cooled Oil Cooler Water Cooled Oil Cooler HOW Series Iron particle type: HOWF series FH Copper particle type: HOW series HOW Series Heat transfer area (Inside pipe) (m ) Heat exchange (kw) Flow rate (L/min) Oil side side

More information

SECTION A-A. Blower Housing. Settling Zone Volume times daily flow. Treatment Zone. SaniTEE 818-B. Vent. Shutoff Valve.

SECTION A-A. Blower Housing. Settling Zone Volume times daily flow. Treatment Zone. SaniTEE 818-B. Vent. Shutoff Valve. A Shutoff Valve Influent Distribution Box See note 11 Volume 0.5-1 times daily flow Mixing Pump Recirculation Pump Discharge SaniTEE 818-B Recirculation Pump Vent Control Panel Blower Housing A NOTES 1.

More information

Energy Systems. Rainwater utilisation. Mini-wastewater treatment plants and cesspits. Living full of energy

Energy Systems. Rainwater utilisation. Mini-wastewater treatment plants and cesspits. Living full of energy Energy Systems Rainwater utilisation Mini-wastewater treatment plants and cesspits Living full of energy We can make a significant contribution towards saving our water resources and also create ecologically

More information

POLYLOK / ZABEL PRODUCT BROCHURE v.3

POLYLOK / ZABEL PRODUCT BROCHURE v.3 POLYLOK / ZABEL PRODUCT BROCHURE v.3 Heavy Duty Trench Drain (Black, Grey, Green, Tan & Ductile ) 3, 4, 6, 8, 10 & 12 Black & Green Pipe s Flow Gate 12 Polylok & Pipe Adapter Ring x3 / Pan x2 & 24 x2 X-Chairs

More information

E 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e

E 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e R e t u r n F i l t e rs E 443 E 453 E 463 E 643 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min 20.50-4e D e s c r i p t i o n Application In the return line circuits of hydraulic

More information

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service Heavy Duty Sump Pumps SERIES Quality Design Features Assure Long, Trouble-Free Service WIDE RANGE OF APPLICATIONS: Industrial Process Pollution Control Sump Drainage Flood Control Hazardous, Toxic & Inflammable

More information

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No.

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No. OF SURVEY OVERALL PLAN - LOW PRESSURE SEWER MAIN 0 50 100 SCALE BAR 1:2500 200 500 THIS IS NOT A LEGAL PLAN - CONCEPT ONLY OF SURVEY PLAN - LOW PRESSURE SEWER MAIN 0 50 100 SCALE BAR 1:2500 200 500 THIS

More information

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems

More information

POLYDOX 6. instruction manual

POLYDOX 6. instruction manual POLYDOX 6 instruction manual Table of contents 1.) Producer: Polyduct ZRT. 3 2.) Standard No.: EN 12 566-3 3 3.) Characteristics 3 4.) Terms of use: 3 4.1. Construction of POLYDOX Waste water treatment

More information

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system Is the pretreatment doing its job? Advanced Treatment Inspection ATUs, Treatment filters, Disinfection & Drip Treatment Pathogens Nutrients Acceptance Sizing BOD/TSS Other Aerobic Treatment Units (ATU)

More information

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system

Advanced Treatment Inspection. Aerobic Treatment Units (ATU) Is the pretreatment doing its job? How do they work? Aeration. SIX parts of the system Is the pretreatment doing its job? Advanced Treatment Inspection ATUs, Treatment filters, Disinfection & Drip Aerobic Treatment Units (ATU) Treatment Pathogens Nutrients Acceptance Sizing BOD/TSS Other

More information

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO

More information

WASTEWATER TREATMENT DISSOLVED AIR FLOTATION PLANTS. Dissolved air flotation plants

WASTEWATER TREATMENT DISSOLVED AIR FLOTATION PLANTS. Dissolved air flotation plants WASTEWATER Dissolved air flotation plants DISSOLVED AIR FLOTATION PLANTS IDROFLO dissolved air flotation plants are designed to treat industrial waste water, water clarification, primary waters with silt

More information

ISO WASTEWATER TREATMENT SYSTEMS. JFC Polska Sp. z o.o. www: oczyszczalnie-jfc.pl ENVIRONMENTAL LY CERTIFIED HIGHEST QUALITY ISO WE HAVE

ISO WASTEWATER TREATMENT SYSTEMS. JFC Polska Sp. z o.o. www: oczyszczalnie-jfc.pl ENVIRONMENTAL LY CERTIFIED HIGHEST QUALITY ISO WE HAVE WASTEWATER TREATMENT SYSTEMS WE HAVE MARKING ACCOR- DING TO 12566-3+A2:2013 ENVIRONMENTAL LY CERTIFIED ISO 14001 HIGHEST QUALITY ISO 9001 JFC Polska Sp. z o.o. www: oczyszczalnie-jfc.pl Index Wastewater

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION OASIS CLEARWATER RETROFIT (RETROFIT AEROBIC WASTEWATER TREATMENT SYSTEM) TECHNICAL SPECIFICATION 8 Persons Domestic Situation 1,600 litres maximum intermittent loading per day COMPLIANCE: N.Z. TP 58 Approval

More information

CONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018

CONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018 CONSTRUCTION OF ELEVATED WATER TANK & WATER WELL VAULT INTERNATIONAL CAMPUS AUGUST 2018 E S SEPTIC TANK N W BASKETBALL COURT ELEVATED WATER TANK MAN HOLE WATER WELL VAULT 1 0 SITE PLAN OF NO NAME INITL

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

ELS LEVEL SWITCH ELS. ELS B10p, ELS B10x, ELS B101x ELS K01, ELS K02, ELS K03 ELS P01, ELS P03, ELS P04

ELS LEVEL SWITCH ELS. ELS B10p, ELS B10x, ELS B101x ELS K01, ELS K02, ELS K03 ELS P01, ELS P03, ELS P04 ES evel sensors are used for tank level control. Different protection connection, material kinds are available. Working Princible: When magnetic field of magnet within the buoy moving along tube according

More information

Rainwater Harvesting. for domestic properties. Environmental Wastewater Solutions

Rainwater Harvesting. for domestic properties. Environmental Wastewater Solutions Rainwater Harvesting for domestic properties Environmental Wastewater Solutions www.wpl.co.uk Why do we need Rainwater Harvesting? Climate change: our precious water reserves are declining Up to 50% of

More information

SOIL and WATER SCIENCE

SOIL and WATER SCIENCE 4-H-1028-W Level 2 Grades 6 8 SOIL and WATER SCIENCE CONTENTS Manual Covers Careers in Conservation Clean Water Color Clues Conservation Practices Floodplains Kankakee Marsh Municipal Water Treatment Onsite

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Date: 13/04/2015 1:14:38 PM

Date: 13/04/2015 1:14:38 PM Date: 13/04/2015 1:14:38 PM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow Systems\FSI-1000-FS_On-Lot Infrastructure Installation Set Out Details.dwg Date: 25/02/2015 11:18:14 AM Cad File No: J:\500-Cad-data\Standard_Drawings\Flow

More information

Section 10 Design Criteria: Components

Section 10 Design Criteria: Components 1. Tanks and Vaults Section 10 Design Criteria: Components a. Watertightness i. Septic tanks, vaults, dosing tanks, other treatment components, risers and lids must not allow infiltration of ground water

More information

Service Saddles/ Brass Alloy/ Stainless Steel Straps for Cast, Ductile & PVC Pipe

Service Saddles/ Brass Alloy/ Stainless Steel Straps for Cast, Ductile & PVC Pipe F 1 F 1.1 F 1.2 F 2 F 2.1 F 3 Service Saddles/ Hinged Type for 2 PVC Service Saddles/ Brass Alloy/ Stainless Steel Straps for Cast, Ductile & PVC Pipe Service Saddles/ Ductile Iron/ Stainless Steel Straps

More information

Terre Kleen Maintenance Procedures

Terre Kleen Maintenance Procedures Maintenance Record Terre Kleen Maintenance Procedures When a Terre Kleen unit is newly installed, quarterly inspection is highly recommended. The design of the Terre Kleen unit permits easy inspection.

More information

Environmental BA-BD. Envirosafe. Advanced Sewage Treatment Systems. Sustainable, Reliable, Affordable

Environmental BA-BD. Envirosafe. Advanced Sewage Treatment Systems. Sustainable, Reliable, Affordable Environmental BA-BD Envirosafe Advanced Sewage Treatment Sustainable, Reliable, Affordable Klargester Envirosafe Introducing the new Envirosafe range Heightened environmental standards, more stringent

More information

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) PART 1 GENERAL 1.1 SCOPE 1.1.1 The manufacturer shall furnish a low profile, multi-tray Air Stripper for removal of volatile organic

More information

The right partner for your project. Drainage and water supply

The right partner for your project. Drainage and water supply Our technology. Your success. Pumps n Valves n Service The right partner for your project. Drainage and water supply 02 Introduction Always the right solution It is not only large projects that place high

More information

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota Pump Tank and Pretreatment Inspection & Troubleshooting Sara Heger University of Minnesota sheger@umn.edu Evaluate Presence of Odor Odors are improper venting Check seals Lid Conduit Tank Access a. Access

More information

HCP Product Introduction

HCP Product Introduction HCP Product Introduction CHAPTERS 1.HCP PUMP 2.Description of products 3.Relevant information of technology 1.HCP PUMP Company Introduction Establish time:1979 Annual sales volume: US$20,000,000 Increased

More information

Accessories and Tools

Accessories and Tools AFN2 Universal Safety Clips Pre-installed in the IP66 and IP68GT range of connectors Allow for a quick and easy connection to PMAFLEX conduits by just pushing the conduit into the connector IP66, DARK

More information

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are

More information

a) Biological Oxygen Demand b) Biology Oxygen Demand c) Biochemical Oxygen Demand d) Biomicrobics Oxygen Demand

a) Biological Oxygen Demand b) Biology Oxygen Demand c) Biochemical Oxygen Demand d) Biomicrobics Oxygen Demand Onsite Domestic Wastewater Treatment, Dispersal and Reuse Biosystems Engineering 532 Final Exam Fall 2008 Due by 4:00 p.m. Monday December 8, 2008 (either by email or hardcopy) Name Instructions: This

More information

Industrial Pumps MAGNETIC DRIVE PUMPS MECHANICAL DRIVE PUMPS VERTICAL PUMPS

Industrial Pumps MAGNETIC DRIVE PUMPS MECHANICAL DRIVE PUMPS VERTICAL PUMPS 1 Lindenwood Drive, Suite 5 Malvern Pennsylvania 19355 T 8.875.308 F 8.875.973 E sales@specialtyplastics.com Industrial Pumps MAGNETIC DRIVE PUMPS MECHANICAL DRIVE PUMPS VERTICAL PUMPS Magnetic Drive Pumps

More information

SPECIAL SPECIFICATION 3504 Septic Tank System

SPECIAL SPECIFICATION 3504 Septic Tank System 1993 Specifications CSJ s 3136-01-126, etc. & 0683-01-070, etc. SPECIAL SPECIFICATION 3504 Septic Tank System 1. Description. This Item shall govern for all materials, equipment and labor necessary for

More information

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps... PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Vertical

More information

Description of the Work

Description of the Work Description of the Work Construction,Supplying of Electro Mechanical equipment, pipe fittings, erection, installation, testing and commissioning MBBR technology Sewage Treatment Plant ( 300 KLD) at kh.no.54,city

More information

PETREX -CNT. Pipe systems for petrol stations Technical details

PETREX -CNT. Pipe systems for petrol stations Technical details PETREX - Pipe systems for petrol stations Technical details Contents 1.0 1.0 Contents 1.10 1.100 System description System description PETREX - 1.11 1.11.01 Product overview Piping, connections, fittings

More information

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l ATTACHMENT 1 GENERAL FACILITY INFORMATION 1. Facility Name: 2. Type of Facility: 3. Population Served: Present: Design: 4. Flow: Average Maximum Peak 5. Water Quality: Present Design Assumed Actual Source:

More information

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115

SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115 SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPSE3A 1/3 44 0 1½ NPT EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPE4A-1 PL-CPE5A-1 PL-CPEH5A1 PL-CPSTEP51A PL-CPSTEP10A

More information

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,

More information

> Pre-installation reference guide Toroid underground tanks >

> Pre-installation reference guide Toroid underground tanks > > Pre-installation reference guide Toroid underground tanks > The patent and copyright are the property of Viscount Rotational Mouldings Pty. Ltd, and may not be reproduced without the written permission

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR

More information

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Pressure Booster System. Hya-Eco VP. Type Series Booklet Pressure Booster System Hya-Eco VP Type Series Booklet Legal information/copyright Type Series Booklet Hya-Eco VP KSB Aktiengesellschaft Frankenthal All rights reserved. Contents provided herein must neither

More information

AUTOMATIC AIR VALVES For potable water

AUTOMATIC AIR VALVES For potable water AUTOMATIC AIR VALVES For potable water Page N Air release valve Page N Air release valve avent Page N Air release valve DN 0 / DN 0, DN 150 / DN 00 Page N /1 Page N5 Combined air release valve Page N 5/1

More information

GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves

GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves GESTRA Gravity Circulation Checks and DISCO Non-Return Valves GESTRA DISCOCHECK Dual-Plate Check Valves and DISCO Swing Check Valves A2 Page DISCO Non-Return Valves Gravity Circulation Checks and DISCO

More information

Class 125S/200WOG Bronze Gate Valve Non-Rising Stem, Threaded Ends Testing: BS EN 12288, BS 5154, BS EN Working Pressure: PN16

Class 125S/200WOG Bronze Gate Valve Non-Rising Stem, Threaded Ends Testing: BS EN 12288, BS 5154, BS EN Working Pressure: PN16 Class 125S/200WOG Bronze Gate Valve Non-Rising Stem, Threaded Ends Testing: BS EN 12288, BS 5154, BS EN 12266 Working Pressure: PN16 FIG. 201 WORKING PRESSURE Working Pressure Non-Shock (psi) Saturated

More information

Compact Waste Water Treatment MBR /MBBR Technology

Compact Waste Water Treatment MBR /MBBR Technology Compact Waste Water Treatment MBR /MBBR Technology 1 Minimal Operation and Maintenance Costs and use of Chemicals 2 Recycle and Reuse water for Irrigation and Recreation 3 Save Water, Energy, Money and

More information

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE I. SCOPE This guide has been prepared to inform the residential property owner of the permitting process

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERIM GUIDE CRITERIA FOR AEROBIC BACTERIAL GENERATOR FOR INSERT INTO SEPTIC TANKS, GREASE INTERCEPTORS AND GREASE TRAPS IAPMO IGC 180-20023

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

Best Practice in Sewage and Effluent Treatment Technologies

Best Practice in Sewage and Effluent Treatment Technologies Best Practice in Sewage and Effluent Treatment Technologies Contents 1 Wastewater - Introduction 1 1.1 Earth s ecological system 1 1.1.1 Water effect on ecology 2 1.1.2 Wastewater generation 3 1.2 Wastewater

More information

MV en /7 MV Knife gate valve DN

MV en /7 MV Knife gate valve DN 1/7 The Stafsjö knife gate valve is a valve designed for a wide range of process industry applications. Its main applications are fluids and suspensions up to 5%. It is also used in services with sludge,

More information

Operating Instructions

Operating Instructions Operating Instructions Fluidised media reactor with hang on option Model No. FMR-75 FMR-75 Please read these instructions before use and save for future reference 1 Description The D-D FMR-75 fluidised

More information

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE

More information

SPC recently concluded a partnership with a leading Italian company providing innovative and complete polyethylene pipe systems in 30 countries.

SPC recently concluded a partnership with a leading Italian company providing innovative and complete polyethylene pipe systems in 30 countries. 50 corrugated pipes SPC celebrates 50 years of manufacturing concrete pipes and related products for the Southern African market. To further serve the region, SPC is proud to announce the manufacturing

More information

Commonwealth of Massachusetts City/Town of Septic System Installation Checklist

Commonwealth of Massachusetts City/Town of Septic System Installation Checklist Important: When filling out forms on the computer, use only the tab key to move your cursor - do not use the return key. DEP has provided this form for use by local Boards of Health if they wish to do

More information

Shower and Floor Gullies SECTION

Shower and Floor Gullies SECTION Shower and Floor Gullies SECTION Shower and Floor Gullies 9 General Information McAlpine has responded to market conditions and customer demand by producing an extensive range of Shower and Floor Gullies

More information

UNDERGROUND DRAIN, SEWER, SURFACE WATER & DUCT

UNDERGROUND DRAIN, SEWER, SURFACE WATER & DUCT www.brettmartin.com UNDERGROUND DRAIN, SEWER, SURFACE WATER & DUCT QUALITY UNDERGROUND SYSTEMS When you select an underground system you need to be sure of its pedigree, convinced of its ability to perform,

More information

ROTH MultiTank. Call or visit our web site at

ROTH MultiTank. Call or visit our web site at ROTH MultiTank Call 866-943-7256 or visit our web site at www.roth-america.com R O T H Mu lt i Ta n k Setting the standards for all other tanks. The Roth MultiTank offers undisputed best-in-class status

More information

The right partner for your project. Drainage and water supply

The right partner for your project. Drainage and water supply Our technology. Your success. Pumps n Valves n Service The right partner for your project. Drainage and water supply 02 Introduction Always the right solution It is not only large projects that place high

More information

OUR POWER, YOUR SATISFACTION

OUR POWER, YOUR SATISFACTION OUR POWER, YOUR SATISFACTION DIAMOND SERIES Industrial pumps DN / JN series NR_BCH_EN_002 R01 25/01/2016 Flanged Industrial Series The DN and JN Diamond series is the best solution for the industrial sector

More information

Underground fire hydrants

Underground fire hydrants Underground fire hydrants The company was founded in 987 by transforming the former CSA, which was a trading company dealing with pipes and valves for water networks, into a manufacturing company, through

More information

The multi-shaft! New for Infiltration shaft system DN 400/600. Inspection shaft. Filter shaft. Choke drain shaft. Infiltration ditch

The multi-shaft! New for Infiltration shaft system DN 400/600. Inspection shaft. Filter shaft. Choke drain shaft. Infiltration ditch Infiltration shaft system DN 400/600 The multi-shaft! New for 2011 Inspection shaft Filter shaft Choke drain shaft Infiltration ditch edition 2011 EN 960439 - sales folder Infiltration 31 GRAF Infiltration

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 PERFORMANCE CURVE VOX 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

DRINKING WATER STORAGE TANK

DRINKING WATER STORAGE TANK Technical Sheet * TECHNICAL DATA Operating range: maximum flow rate 120 l/min, head up to 65 metres Pumped fluid: clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallised

More information

SECTION GROUND WATER STORAGE TANKS

SECTION GROUND WATER STORAGE TANKS SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION

More information

C.A.S.E. Air Carrier Section Policies and Procedures

C.A.S.E. Air Carrier Section Policies and Procedures FUEL STORAGE CHECKLIST Audit Date: Station Code: City: Vendor Name: Address: Primary Contact: Title: Phone: Fax: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register: (Circle One) Add

More information

The International Committee of the Red Cross

The International Committee of the Red Cross The International Committee of the Red Cross WATER & HABITAT DEPARTMENT Rozhawa / Hospital / Rehabiliation Phase II Rozhawa Hospital / Erbil City / Erbil 25 - February - 217 Rozhawa / Hospital / Rehabiliation

More information