DILLARD'S INC TEST PROTOCOL FOR DILL USA- (V21) SMALL NON-LEATHER GOODS (POUCHES, HOLDERS, ETC.)
|
|
- Harry King
- 6 years ago
- Views:
Transcription
1 By/Date: Page 1 of 5 Evaluation Citation / ethod No. of Criteria Notes esult ating SCOPE: This protocol is applicable for testing of small non-leather goods (pouches,holders,etc). SUPPLEENTAY POTOCOL Note: Additional cost, sample size & TAT may be required if testing to 1 or more supplemental protocols is necessary. Please refer to the below referenced supplemental protocol(s) for additional information. A California Proposition 65 DILL-AN-PTCL USA - The sample should be reviewed against the requirements of California Proposition 65. LABELING US Packaging labeling Country of origin marking Use labeling ANALYTICAL A Total lead in surface coating F.P. and L. Act (16 CF 500) O NIST Uniform Laws and egulations Handbook Packaging shall be labelled with the following, Product Identification Net quantity of contents shall be expressed in terms of weight or mass, measure, numerical count, or combination so as to give accurate information to facilitate consumer comparison (U.S. and metric units) anufacturer, packer, or distributor s name & address (City, State & Zip Code) 19 CF Shall indicate country of origin legibly, permanently, and in comparable size and close proximity to any mention of country other than country in which the article was manufactured or produced. ust be visible at point of purchase. CPSC-CH-E / CPSD-AN PHYSICAL CHAACTEISTICS Dimensions CPSD-GB Dimensions - CPSD-GB thickness Weight CPSD-GB Capacity - CPSD-HL volumetric 1 Use/care instructions shall be clear, concise and understandable, provide stepby-step method of use and be provided in language appropriate to destination countries. Provide a copy of the instructions in the report. - All accessible surface coatings in the as received state on items outside of the scope of 16 CF 1303 shall not contain lead or lead components in which the lead content is in excess of 0.009% (90 ppm) of the weight of the total content. eport actual results or include data table within report. Component testing is allowed. Compositing up to 3 colors is allowed. Client requirement 1 eport overall dimensions; shall meet label claims. 1 eport overall thickness. Shall meet label claims. 1 eport overall weight; shall meet label claims. 1 eport overall capacity; shall meet label claims.
2 By/Date: Page 2 of 5 Evaluation Citation / ethod No. of Criteria Notes esult ating Parts inventory 1 Shall meet label claims. All listed hardware must be provided. Features All Shall be as claimed. aterial type 1 Shall be as claimed. WOKANSHIP Sharp point and sharp edge 16 CF & 49 (od) All Shall have no sharp points / edges, other than those required for function. odification: Expanded scope to other products. Defects and workmanship All Shall have no discernible surface degradation, including crazing, shivering, denting, bubbles, cracks, stains, deformations, chips, fractures, heavy lines, waves, shear marks, scratches, scuff marks, indentations, or blisters. aterial quality PEFOANCE Actual use - functionality Attachment strength Breaking strength of textile fabrics: grab test CPSD-GB CF (od) / AST F Section 8.8 & 8.9 (od) AST D Seam strength AST D e1 (od) Handle 45 degree Operability of zippers AST D e1 (od) AST D All Shall have no components missing, malformed, and/or fractured. No major defects. All Shall function as intended as received. eport details of evaluation (features tested / methods used / materials used / etc.) eport any features not evaluated. 1 [Additional tests for child and baby leather accessories] 15 lb for 10 seconds. odification: Expanded the scope to other than apparel. inimum 25 lbf Note: Pass / fail base on result of overall fabric break. 2 Bottom / side seam: 25 lb. minimum. Lining seams - woven: 7 lb. minimum. Lining seams - vinyl: 10 lb. minimum. Zipper seam: 25 lb. minimum. odification: Expanded the scope to other than apparel. 2 Handles or shoulder straps: 25 lb minimum. odification: Expanded scope to other products 1 [Open and close] Functional
3 By/Date: Page 3 of 5 Evaluation Citation / ethod No. of Criteria Notes esult ating Strength tests for zippers AST D Cross widthwise strength: 50 lb. minimum. Scoop pull: 10 lb. minimum. Top stop: 20 lb. minimum. Bottom stop: 20 lb. minimum. Slider torque: 2 lb-in minimum. Slider pull: 5 lb. minimum. Holding strength AST D All 15 lb per 10 seconds of snap fasteners esistance to snapping and unsnapping of snap fasteners Button/small parts attachment strength Button impact resistance Abrasion resistance of fabric - inflated diaphragm apparatus esistance to flexing - vinyl esistance to corrosion COLOFASTNESS A Colourfastness to artificial saliva Colorfastness to crocking Colorfastness to rotary crocking (2016) CPSD-SL CPSD-SL CPSD-SL AST D (2015) SATA P 55 (od) AST B (mod) / CPSD-HL inimum 2 lb aximum 8 lb 1 15 lb for 10 seconds. 1 No fractures of button. 1 No removal of upper surface after 300 cycles 1 odification: No cracking after 10,000 cycles. 1 [Applicable to samples or sample components constructed of metal or samples with metallic coatings that can be exposed to the environment] Shall withstand 24 hours in 1% salt spray (fog) with no noticeable oxidation / corrosion / visual changes. odification: 1% salt spray (fog). DIN [Additional test for child and baby leather accessories] 1: Grade 4.0 minimum AATCC [Face/Back/Edge] Dry: Grade 3.0 minimum Wet: Grade 2.0 minimum AATCC [Face / Back / Edge] Dry: Grade 3.0 minimum. Wet: Grade 2.0 minimum.
4 By/Date: Page 4 of 5 Evaluation Citation / ethod No. of Colorfastness to AATCC [Option 3] light [Neon and bright colors only] Grade 4.0 minimum at 10 AFU Criteria Notes esult ating No. Of equired for Complete Testing No. Of (Fully Packed) Cartons For Transit Testing: No. Of Working Days For Complete Testing: 3 1 (Only Upon Dillard s equest) 7 Client Approval: Creation Date: Last evision Date: Pricing eview Date Lucy Feng 12/Jan/ /Jan/ /Feb/2018 Technical eview Date: 13/Feb/2015 Key A Additional Charge For This Test andatory egulatory esult Key C N NA NT Claimed ecorded eets Does Not eet Not Applicable Not Tested ating Key PASS FAIL N Pass Fail Not equested
5 By/Date: Page 5 of 5
1 Use/care instructions that are clear and understandable shall be provided in language appropriate to destination countries.
Test Date: Reviewed By/Date: DILLARD S TEST PROTOCOL FOR SCOPE: This protocol is applicable for testing beverage dispenser with stand. SUPPLEMENTAL PROTOCOLS * California Proposition 65 CPSD-AN-PTCL- 06572-US
More informationDILLARD'S INC TEST PROTOCOL FOR DILL USA- (V30) BRAS
DILL-00805-US- (V30) BS By/Date: Page 1 of 6 Criteria Notes esults ating SCOPE: This protocol is applicable for testing of bras for children and adult. SUPPLEMENTY POTOCOL Note: additional cost, sample
More informationDILLARD'S INC TEST PROTOCOL FOR DILL USA- (V35) LEATHER AND SUEDE
DILLD'S INC TEST POTOCOL FO LETHE ND SUEDE eviewed By/Date: Page 1 of 7 Criteria esults ating SCOPE: This protocol is applicable for testing of adult / children leather and suede in fabric and garment
More informationDILLARD S TEST PROTOCOL FOR DILR US OUTDOOR GAS TABLETOP GRILL (V7)
Test Date: Reviewed By/Date: SUPPLEMENTAL PROTOCOLS * CA Prop 65 Applicable Section from Protocol CPSD-AN- PTCL-06572-US *Food contact CPSD-AN-PTCL-06001- DILLARD S TEST PROTOCOL FOR 1 The sample should
More informationBV Lab Number: Technician Name: Test Date: Reviewed By/Date: DILLARD S TEST PROTOCOL FOR DILR US GIFTWARE (V1) Criteria Results Rating
Test Date: Reviewed By/Date: DILLARD S TEST PROTOCOL FOR SCOPE: Included but not limited to battery operated decorative figurine, coaster set, picture frame with or without wall mounting, wall plaque resin,
More informationDILLARD'S INC TEST PROTOCOL FOR DILL USA- (V19) JEWELRY-COSTUME / SEMI-PRECIOUS (ADULT)
DILL-02050-US- (V19) JEWELY-COSTUME / SEMI-PECIOUS (DULT) By/Date: Page 1 of 8 SCOPE: This protocol is applicable for testing of jewelry-costume / semi-precious (adult). LBELING US Packaging labeling M
More informationDILLARD'S INC TEST PROTOCOL FOR DILL USA- (V38) SPECIAL CLAIMS
DILLRD'S INC TEST PROTOCOL FOR DILL-00992-US- (V38) SPECIL CLIMS By/Date: Page 1 of 7 SCOPE: This protocol predominantly applies to fabric, garment and accessories that include claims with special function
More informationINTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR GLASS LAVATORIES, SINKS AND COUNTER TOPS IAPMO IGC
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR GLASS LAVATORIES, SINKS AND COUNTER TOPS IAPMO IGC 172-200810 1. PURPOSE 1.1 The purpose of this standard is to establish
More informationENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610
ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610 PART 1 - GENERAL 1.1 SCOPE OF WORK FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED STAIR TREADS A. The CONTRACTOR shall furnish,
More informationSOLUTIONS QUALITY GUIDELINES
TABLE OF CONTENTS INTRODUCTION... 3 CONTACT INFORMATION... 3 Technical Design & Quality... 3 Product Technician... 3 II. VENDOR REQUIREMENTS... 4 III. GENERAL QUALITY GUIDELINES... 5 COMPLIANCE... 5 PERFORMANCE...
More informationSL150 Guide Specification
SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union
More informationENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1
ENGINEERING SPECIFICATION PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC 1 PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS
More informationENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING 1 PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING A. The CONTRACTOR shall furnish,
More informationENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES March 16, 2015 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS STRUCTURAL SHAPES PART
More informationSECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
More informationSECTION 8 - GLOBAL INSPECTION PROTOCOL VM DOCUMENT 2017 VERSION 1.0. SECTION 8 Global Inspections Protocol. Page 1
VM DOCUMENT 2017 VERSION 1.0 SECTION 8 Global Inspections Protocol Page 1 This guideline is a Destination Maternity / Intertek Inspection Protocol. 1.0 Highlights/Requirements: 1.1 This protocol is applicable
More informationSECTION 1043 FENCE MATERIAL
SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance
More informationENGINEERING SPECIFICATION PULTRUDED HIGH LOAD CAPACITY (HI) SAFE-T-SPAN FIBERGLASS GRATING. January 24,
ENGINEERING SPECIFICATION PULTRUDED HIGH LOAD CAPACITY (HI) SAFE-T-SPAN FIBERGLASS GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED HIGH LOAD CAPACITY
More informationUltra Aluminum Fence, Rail & Gate Specifications
Ultra Aluminum Fence, Rail & Gate Specifications [This specification contains options and notes in square brackets. The various choices relate to the color, style, size, and component dimensions of the
More informationAAMA Voluntary Specification, Performance Requirements and Test Procedures For Pigmented Organic Coatings on Aluminum Extrusions and Panels
A M E R I C A N A R C H I T E C T U R A L AAMA 2603-02 Voluntary Specification, Performance Requirements and Test Procedures For Pigmented Organic Coatings on Aluminum Extrusions and Panels M A N U F A
More informationSECTION ORNAMENTAL ALUMINUM FENCING
SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS
DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationArchitectural Specifications, Section Phenolic Lockers
Architectural Specifications, Section 10500 Phenolic Lockers Hollman, Inc., 1825 W. Walnut Hill Lane, Irving, TX 75038, (972) 815-4000, www.hollman.com 1.0 GENERAL 1.1 SECTION INCLUDES A. Phenolic Lockers.
More informationGuideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
More informationTENT / SHELTER / TARPS, GLOBAL DEFECT LIST
Date Rev. N Modifications tracking 2009/09/08 1 Initial release 2016/07/14 2 Major changes 9/19/2016 3 Defects A13, B23 and D39 were added. Defect D9 was modified. 2017/1/23 4 Revision per Coleman design
More informationENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS January 24, 2014 06600-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationStop and Read Before Installing Material
Premium Dry Erase Materials Installation procedures for full wall application with woven and nonwoven backed products Stop and Read Before Installing Material Installation Procedures EXAMINATION Jot.a.wall
More informationStandard Specification for Electrodeposited Coatings of Zinc on Iron and Steel 1
Designation: B 633 07 Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel 1 This standard is issued under the fixed designation B 633; the number immediately following the designation
More informationSEI Certification Program Manual
25.7 NFPA 1977-11 Protective Clothing & Equipment for Wildland Fire Fighting A. Definition of Model Clothing Characteristics that should affect the model s ability to meet the performance requirements
More informationRequirements. Western Underground Committee Guide 2.13, Security for Padmounted Equipment Enclosures
1 Scope This specification outlines the minimum requirements for concrete and non concrete equipment bases and enclosures to be used in conjunction with PacifiCorp owned primary rated equipment. The specification
More informationSECTION EXTERIOR INSULATION AND FINISH SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 24 00 1. Use this section only for NCA projects. 2. Detail wall section, base edge, expansion and control joint conditions for each system. Show locations of
More informationSECTION SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS
PRODUCT SPECIFICATIONS - SERIES 1090 SECTION 10170 SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS PART 1 GENERAL 1.01 Work Included A. Toilet Compartments B. Urinal Screens C. Shower Dividers D. Dressing
More informationSTANDARD TEST METHODS
STANDARD TEST METHODS Kate Spade & Company Updated: May, 2017 TABLE OF CONTENTS FABRICS AND APPAREL STANDARD TEST METHODS... 3 Standard Test Method # 1 - LCI Torque Test Method... 3 Standard Test Method
More informationSignature Series 5 Lap SECTION ALUMINUM WINDOWS
Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this
More informationRENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION
STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary
More informationSPECIFICATION GUIDELINE
Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section
More informationExperimental Investigation of the Galvanization. Effects on the Properties of. Low Carbon Alloy Steel
Adv. Theor. Appl. Mech., Vol. 5, 2012, no. 5, 225-236 Experimental Investigation of the Galvanization Effects on the Properties of Low Carbon Alloy Steel Ghazi S. Al-Marahleh Department of Mechanical Engineering,
More informationSECTION CERAMIC EPOXY LINING DUCTILE IRON PIPE AND FITTINGS
SECTION 02500 CERAMIC EPOXY LINING DUCTILE IRON PIPE AND FITTINGS (As provided by Tnemec Company, Inc.) GENERAL 1.1 SUMMARY 1. This Section includes surface preparation and shop application of Series 431
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 09 6816 - SHEET CARPETING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board
1. Scope 1.1 This standard defines the minimum prescriptive quality and performance requirements for Fiberreinforced Magnesium Cement Board products intended for use in buildings in North America. For
More informationPRODUCT GUIDE SPECIFICATION
PRODUCT GUIDE SPECIFICATION Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat,
More informationSECTION ALUMINUM COMPOSITE WALL PANEL SYSTEM
SECTION ALUMINUM COMPOSITE WALL PANEL SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Includes drawings and provisions of the General Conditions, Supplementary Conditions and the sections included under
More informationTHE EFFECT OF PROPOSITION 65 ON THE APPAREL AND ACCESSORIES INDUSTRY
THE EFFECT OF PROPOSITION 65 ON THE APPAREL AND ACCESSORIES INDUSTRY A DISCUSSION ABOUT THE IMPACT AND CHALLENGES OF COMPLIANCE JANUARY 2012 AUTHOR Louann Spirito Director of Technical Support, Softlines
More informationML150 Guide Specification
ML150 Guide Specification This specification is a guide recommendation for many metal roofing projects. It is available for downloading in both Microsoft WORD and.pdf format for your ease of use. Revise
More informationProduct Guide Specification
April 2014 6840 SW 81 Terrace Miami, Florida 33143 Phone 305-666-6676 Fax 305-666-7675 Website www.trimstonepanels.com E-mail stoneworks@stoneworksofart.com Product Guide Specification Specifier Notes:
More informationXorel Summary of Test Results
Physical Results carnegiefabrics.com ( 800 ) 727-6770 All Xorel fabrics are woven with polyethylene yarn of different sizes and shapes. Most Xorel fabrics are inherently flame retardant and are designated
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ATLAS WEATHERING SERVICES GROUP 1500 Bishop Court Mt. Prospect, IL 60056 Lorenzo Tyler Phone: 305 245 3659 Fax: 773-327-5787 MECHANICAL Valid To: May 31, 2018
More informationSalt Spray Resistance
Salt Spray Resistance Test No. TP02 This test procedure is used to determine the resistance of the paint/polymer system used for the Texture Plus system in resisting degradation when subject to salt spray.
More informationSECTION ACCORDION FOLDING PARTITIONS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationSPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
More informationSPECIFICATION GUIDELINE
SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification
More informationSECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.
PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Fusion welded and rackable ornamental steel picket fence system. B. Related sections: 1. Section 03310 Concrete Work for post support. 2. Section 09960
More informationCERTIFIED PRODUCT PERFORMANCE STANDARDS FOR CULTURED MARBLE LAVATORIES
CERTIFIED PRODUCT PERFORMANCE STANDARDS FOR CULTURED MARBLE LAVATORIES 2.GENERAL REQUIREMENTS 2.1 Materials 2.1.1 Filler Materials. The filler materials shall be of grades suitable to produce the performance
More informationSection PANEL SIGNAGE
Section 10 14 23 PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including FDOT DIVISION I GENERAL REQUIREMENTS & COVENANTS Specification Sections,
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationSECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 10 14 23 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationEngineering Branch Assets Delivery Group
F.1 SCOPE This Technical Specification shall apply to Fibre Reinforced Plastics or Glass Reinforced Plastics (hereinafter referred to as FRP or GRP) structures and the materials used in their manufacture,
More informationTEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION SIGN FACE, ROLL-UP, REFLECTIVE, CONSTRUCTION AND WORK ZONE PUBLICATION
TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION SPECIFICATION NO. * SIGN FACE, ROLL-UP, REFLECTIVE, CONSTRUCTION AND WORK ZONE PUBLICATION This specification is a product of the Texas Department
More informationVITRABOND Aluminum Composite Panel Façade System Specification Template
VITRABOND Aluminum Composite Panel Façade System Specification Template SECTION 07 - COMPOSITE METAL WALL PANELS UTILIZING VITRABOND MATERIAL PART 1 GENERAL 1.1 SECTION INCLUDES A. Provide metal composite
More informationTAIYO IJR-4000 MW300
TAIYO IJR-4000 MW300 INKJET LEGEND INK Photos Courtesy of ZOT Engineering Inkjet Application; Fast UV Curing High Cured Hardness Halogen-free; Bright White Color Excellent Adhesion to Semi- and Fully-Cured
More informationSECTION BRICK MASONRY ASSEMBLIES
PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Face brick. 2. Mortar and grout. 3. Ties and anchors. 4. Miscellaneous masonry accessories. 1.2 SUBMITTALS A. Product Data: For each type
More informationNumber: 075K0013. Machined surfaces of incoming components must be masked before coating, unless otherwise directed by Engineering.
Number: Name: Organic Coating Performance Requirements for DDC, HDEP, MBE, and MTUDD Components and Engines. Source: MATERIALS ENGINEERING, Jeremy Dean Latest Revision Date: 04/01/2007 Previous Revision
More informationRIGID ENDOSCOPE OPERATING INSTRUCTIONS
RIGID ENDOSCOPE OPERATING INSTRUCTIONS Note: Read this manual first. It contains important instructions and warnings concerning the proper assembly, use, and service of your new rigid endoscopy product(s).
More informationGuide Specifications Section
Guide Specifications Section 08 87 13 SOLAR CONTROL FILMS LLumar Dual Reflective Series Note: Click on Show/Hide button to reveal "Specifier Notes" throughout section. Delete this text when editing is
More informationMATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1541 NOVEMBER 2005 (Reissued November 2010) MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS TABLE OF CONTENTS 1541.01 SCOPE 1541.02 REFERENCES
More informationMODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS
MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes
More informationConsumer Product Safety Improvement Act (CPSIA)
Consumer Product Safety Improvement Act (CPSIA) Updated: September 2014 1. GENERAL CERTIFICATION OF CONFORMITY (GCC)... 3 2. CPSIA HIGHLIGHTS... 3 3. SCOPE OF CPSIA... 4 4. DOCUMENTATION OF GCC OR MANUFACTURER
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Q-LAB DEUTSCHLAND GMBH In den Hallen 30 66115 Saarbrücken, Germany Markus Weyland Phone: +49 681 857470 Email: mweyland@q-lab.com Website: www.q-lab.com MECHANICAL
More informationTAMDID PIPES GRP MANHOLE BROCHURE
TAMDID PIPES GRP MANHOLE BROCHURE 1) Types & Description of Manholes: Tamdid Pipes offer two types of Manholes; Structural and Liner Manholes: a. Structural Manholes Tamdid Pipes offers concentric and
More informationHigh Pressure Laminate General Specifications
High Pressure Laminate General Specifications High Pressure Laminate General Specs Description Attributes High Pressure Laminate (HPL) is a combination of specially developed, digitally imaged paper which
More informationTRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS
TRIDENT SEC 04 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS A.
More informationDETAIL SPECIFICATION PLATES, TAGS, AND BANDS FOR IDENTIFICATION OF EQUIPMENT, GENERAL SPECIFICATION FOR
INCH-POUND MIL-DTL-15024F 28 November 1997 SUPERSEDING MIL-P-15024E 29 January 1993 DETAIL SPECIFICATION PLATES, TAGS, AND BANDS FOR IDENTIFICATION OF EQUIPMENT, GENERAL SPECIFICATION FOR This specification
More informationNudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS
SECTION 09 7720 FIBERSCORE FIBERGLASS REINFORCED WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Prefinished polyester glass reinforced plastic sheets and adhered to unfinished [gypsum] [cementitous]
More informationSection 6- Carton Packing, Packaging, Labeling & Shipping Requirements Packing and Packaging Guidelines Thousands of cartons are received weekly in
Section 6- Carton Packing, Packaging, Labeling & Shipping Requirements Packing and Packaging Guidelines Thousands of cartons are received weekly in our Service Center. In order to expedite the receiving
More informationMATTEL INC. Technical Report: (5215) / (5215) (A) November 03, 2015 Page 1 of 13
CONSUER PRODUCTS SERVICES DIVISION ATTEL INC. Technical Report: (5215)293-0804 / (5215)237-0391 (A) Page 1 of 13 ALCO HON / ROSANNE CANUS STUDIO FUN INTERTIOL UNIT 1501-8, ILLENNIU CITY 5 (AP) 418 KWUN
More informationPERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960
STUC-O-FLEX PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all labor, materials and equipment
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationCritical Cover Microbreathe Garments
2 Critical Cover Microbreathe Garments Critical Cover Microbreathe Garments Suitable for Use in Controlled Environments Features & Benefits: Choose Microbreathe garments for their outstanding protection,
More informationGuide Specifications Section
Guide Specifications Section 08 87 13 SOLAR CONTROL FILMS LLumar Deluxe Series Note: Click on Show/Hide button to reveal "Specifier Notes" throughout section. Delete this text when editing is complete.
More informationPH6000. Key Features
Phenolic Locker Series PH6000 Key Features ½ inch doors and end panels Durable, backed by a 20 year warranty. Ideal choice for wet-use areas including pools and recreation centers Graffiti resistant, permanent
More informationSTRAP & CORNER PROTECTORS / STRAP STAPLES PLASTIC STRAPPING DISPENSERS
PLASTIC STRAPPING Complete Packaging Products offers all varieties of Plastic Strapping; Poly Cord, Polyester and Polypropylene. To utilize your plastic strapping we carry a broad range of Strapping Tools.
More informationZZ-M-71F February 26, 1987 SUPERSEDING ZZ-M-71E May 3, 1979 FEDERAL SPECIFICATION MATTING, RUBBER AND VINYL
ZZ-M-71F February 26, 1987 SUPERSEDING ZZ-M-71E May 3, 1979 FEDERAL SPECIFICATION MATTING, RUBBER AND VINYL This specification was approved by the Commissioner, Federal Supply and Services, General Services
More informationSECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)
SECTION 02623 HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required and install high density
More informationTRIDENT S8 DN 35 SECTION SAFETY AND SECURITY FILMS
TRIDENT S8 DN 35 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS
More informationREQUEST FOR PROPOSAL WAYFINDING SIGN DESIGN AND FABRICATION FOR THE CITY OF SALIDA, COLORADO
REQUEST FOR PROPOSAL WAYFINDING SIGN DESIGN AND FABRICATION FOR THE CITY OF SALIDA, COLORADO I. INVITATION AND INTENT The City of Salida invites all interested, qualified persons or firms capable of providing
More informationThermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)
PAGE 1 OF 7 1. GENERAL 1.1 SECTION INCLUDES.1 All requirements of the contract documents form an integral part of the work specified herein; in particular refer to the general conditions and Division 1
More informationApparel Inspection Requirements for Vendors
Ascena Global Sourcing Apparel Inspection Requirements for Vendors Version 1.0 0 TABLE OF CONTENT 1.0 PURPOSE 2 2.0 APPLICATION.. 2 3.0 PRE INSPECTION.. 2 4.0 CONFIRMATIONN 2 5.0 SCHEDULING 2 3 6.0 IN
More informationSection Sliding Aluminum Framed Glass Doors (2500 Model Specifications)
Section 083213 - Sliding Aluminum Framed Glass Doors (2500 Model Specifications) I. GENERAL: SECTION 083213 SLIDING ALUMINUM- FRAMED GLASS DOORS 1.01 Scope of Work A. Furnish all necessary materials, labor,
More informationSST-II HYDRAULIC BI-FOLD SPECIFICATIONS
PART 1 GENERAL 1.01 DESCRIPTION A. General 1. Furnish SST-II Hydraulic Bi-Fold System complete from one manufacturer. Provide all labor, materials, tools and equipment to furnish the SST-II Bi-Fold System
More informationSpecification Floor-To-Ceiling Solid Plastic Toilet Compartments
Specification Floor-To-Ceiling Solid Plastic Toilet Compartments PART 1 GENERAL 1.01 SUBMITTALS A. Plastic compartment work includes the following, where indicated: 1. Floor-to-ceiling compartments. B.
More informationFashion Manufacturers Ltd. Quality Assurance Program
Fashion Manufacturers Ltd. Quality Assurance Program MISSION As the fashion business becomes increasingly competitive, the quality of our product must improve. For this reason, we have created this Quality
More informationA. American Association of Textile Chemists and Colorists (AATCC): 1. AATCC 16, Test Method of Colorfastness to Light.
PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of Texas State University-San Marcos for sheet carpet. B. Texas State University-San
More informationZZ-T (GSA-FSS) March 25, 1970 INTERIM FEDERAL SPECIFICATION TREAD, STAIR, FLEXIBLE AND SEMI-RIGID TYPE RUBBER AND VINYL
March 25, 1970 INTERIM FEDERAL SPECIFICATION TREAD, STAIR, FLEXIBLE AND SEMI-RIGID TYPE RUBBER AND VINYL This Interim Federal Specification was developed by the Federal Supply Service, General Services
More informationCOMMERCIAL ITEM DESCRIPTION CONTAINER, THERMAL, SHIPPING, FOR MEDICAL MATERIEL REQUIRING CONTROLLED TEMPERATURE RANGES
INCH-POUND A-A-0059195E 1 September 2015 Superseding A-A-0059195D 25 March 2015 A-A-0059195C 20 August 2010 A-A-0059195B 24 June 2009 A-A-0059195A 27 May 2003 A-A-59195 28 March 1998 COMMERCIAL ITEM DESCRIPTION
More informationMECHANICAL AND PHYSICAL PROPRIETIES
Kera-Coat Ceramic Coatings are Special Ceramic Coating defined as a substantially vitreous or glassy inorganic coating bonded to metal by fusion at a temperature above 800 F. In this short abstract we
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS ITEM 00663 TRAFFIC BUTTONS & PAVEMENT MARKERS 663.1 Description. This item shall consist of furnishing and installing traffic buttons and reflectorized pavement markers and jiggle
More informationTHERMALLY BROKEN STEEL WINDOWS STEEL WINDOW INSTITUTE A STANDARD OF EXCELLENCE
THERMALLY BROKEN STEEL WINDOWS A STANDARD OF EXCELLENCE STEEL WINDOW INSTITUTE WHY? Elegant Narrow Sightlines Superior Strength and Durability Unparalleled Security Structural Integrity Extra Deep Glazing
More information