Glass Tube Flowmeter. Datenblatt 10A1190. Rugged and simple industrial instrument

Size: px
Start display at page:

Download "Glass Tube Flowmeter. Datenblatt 10A1190. Rugged and simple industrial instrument"

Transcription

1 atenblatt 8S0U02 Field IT Glass Tube Flowmeter Function Rugged and simple industrial instrument for metering the flow of liquids and gases. pplication reas Suitable for many industries including apparatus manufacture, food industry, water treatment and chemistry industry. large variety of fluid wetted materials are available for metering aggressive fluids. dvantages Precision meter tubes incorporating flat guides, bead guides or pole guides. Stainless steel housing standard. O-ring seals assure easy meter tube removal. Meter tubes and floats can be interchanged independent of each other. Important esign Features magnetic actuated alarm transmitter can be added in meter sizes / [N5] and larger. (See 55X000 (Ex) ig5). Functional usefulness certified by the VGW-Research enter of the Engler-Bunte-Institute. Suitable for vacuum service. Polycarbonate safety protection tube for metering gases. ouplings allow quick and easy installation and removal of the flowmeter. Rugged and simple industrial instrument

2 8S0U02 Specifications Scale esigns iameter Ratio Scale k/s For meter sizes / to /, direct reading if desired Percent Scale For meter sizes / to /,direct reading or mm scale if desired Materials, onnections, Weight Materials Fluid Wetted Parts Standard Others Meter tube Borosilicate glass Float Meter size / & /8 Glass SS3 No..0 Sapphire arboloy Tantalum Float stop Inlet / Glass SS3 No..0 Sapphire arboloy Tantalum / to SS30 No..30 SS3Ti No..57 Hast. B/ PV L Bronze PV (lead filled) PTFE / /8 & / / to Outlet / to / / to / to SS30 No..30 SS3 No..0 SS30 No..30 SS3 No..0 Scale Lengths 00 mm for meter tube size / 30 mm for meter tube sizes /8 to / 0 mm for meter tube sizes / to ccuracy lasses (per VI/VE 3) Meter tube size / : 6 Meter tube sizes /8 to :,6 Meter tube size / to w/ BL float design: 6 onnections hreaded or flanged connections, see imensions Page 9 Weight See imensions Page Hast. B/ SS30 No..30 PTFE PVF, PV, SS30 No..30 Fittings / to SS3Ti No..57 Steel PV ) PF O-Rings Buna N Viton Ethylen-Propyl. Others Housing Flanges SS30 No..30 SS30 No..30 Max. llow. Operating Pressure Liquids Gases Meter Size Pressure [bar] Pressure [bar] / /8 / / 3/ / Reductions to the max. allow. operating pressure: For meter sizes to the max. allow. operating pressure is reduced by % per 2 for operating temperatures over 95. The pressures are lower for gas applications due to safety considerations. The strength of the Polycarbonate protection tube is reduced as the temperature increases. Therefore the additional restrictions listed below are to be considered when metering gases: Listed max. allow. operating pressures applicable at 30 fluid temperature and 30 ambient temperature. Max. ambient temperature: 0. Max. fluid temperature: 00 For fluid and/or ambient temperatures above 30 º the max. allow. operating pressure is reduced by.05 % /. Fluid Temperatures For Buna N O-rings: 0 to For O-Ringen aus Viton : 0 to 50 For PV floats: 0 llowable min./max. Temperatures TS ombinations Glass /Metal with liquid fluids TSmin = 0 TSmax = +50 ombinations Glass /Metal with gaseous fluids TSmin = 0 TSmax = +00 ombinations Glass /PV, all fluids TSmin = 0 TSmax = +60 ombinations Glass /PVF with gaseous fluids TSmin = 0 TSmax = +00 ombinations Glass /PVF with liquid fluids TSmin = 0 TSmax = + 2

3 8S0U02 Floats Ball Floats are used to meter smaller flowrates in sizes / to /. In order to attain a large number of flow ranges within each meter tube ball floats made of different materials with differing densities are utilized. Floats with Guide Rings are used in combination with bead guide meter tubes. The percent scale is the standard design. Float designs GSVT are essentially viscosity immune and are available in the individual meter sizes in a variety of materials and numerous weights. n increase of flowrate of to 30 % can be achieved if a reversed float head design GNSVT is utilized. This float head design is not suitable for fluids with higher viscosities.the VI values listed in the flow range tables are to be observed. The float is guided by the metering edge and the guide ring along the bead guides in the meter tube. Floats for Pole Guides have a hole through their longitudinal axis and their vertical movement is guided along a stationary rod mounted in the center of the meter tube. Float Shapes BL... are especially suitable for high flowrates in the smaller sizes. They are guided by the bead guides in the meter tube. There are approximately 00,000 possible meter tube - float - scale combinations available for the Variable rea Flowmeters. Floats with Minimum Pressure rop have been specially developed for metering gases at low operating pressures and assure an extremely low pressure drop through the flowmeter. They are used in the bead guide meter tubes. Ball Float Float with Guide Ring Float with Minimum Pressure rop Float with Pole Guides Float GSVT GNSVT GNSVT SV NSV BL = Reading Edge Fig. : Float esigns 3

4 8S0U02 Meter Tubes Glass Meter Tubes Triflat Meter Tubes (Fig. 2) are utilized in the smallest sizes from / to /. There are three flat surfaces which extend along the length of the conical meter tube parallel to its center axis. These flat surfaces guide the float throughout the entire measurement range. The minimal spacing between the float and the meter tube guide surfaces assures that the reading edge of the float is readily visible and that the flowrate value can be determined from the scale even when metering cloudy fluids. The float is guided exactly in the middle of the meter tube. Plain Taper Meter Tubes / to (Fig. 3) are usually installed only for extreme operating conditions (pressure shocks, vibrating pipelines, etc.). The greater cross sectional area relative to the bead guide meter tubes provides larger flow ranges in sizes / -. The float is guide by the pole guide rod in the plain taper meter tubes. Bead Guide Meter Tubes (Fig. ) are the standard meter tubes in sizes / to. In this design the beads, which are parallel to the center axis of the meter tube, serve the same function as the triflats described previously. They guide the float throughout the entire measurement range. In this design too the minimum space between the float reading edge and the meter tube bead guides assures that the float reading edge will be readily visible even in cloudy fluids. They are used in conjunction with the floats with guide rings. Scales iameter Ratio Scale t/f The diameter ratio scales are a numerical representation of the flow area to float head area ratio. This scale is universally used for gases and liquids and is of particular benefit when the operating conditions vary. flowrate table is included at no charge for determining the flowrate values from the scale readings. onversion calculations for other operating conditions are easily made using our Flowalc calculation program. This scale design is the standard scale for the triflat meter tubes with ball floats. Percent Scale The linearized percent scale is the standard scale design for all the other Variable rea Flowmeters, predominantly for the bead guide and plain taper meter tubes. It indicates the flowrate expressed as a percentage of the maximum flowrate and generally covers a range from 8 to 00%. The maximum flowrate can be readily calculated from a knowledge of the physical properties of the fluid and the float design. Each percent scale has its accuracy guaranteed by us. irect Reading Scale These scales indicate the volume or mass flow per unit time directly: (e.g. l/h Hydrogen, cm 3 /Min H 2 O). They are valid only for a single fluid and a specific set of operating conditions. Universal applicability of the direct reading scales is subject to certain limitations. Millimeter Scale This scale design is usually utilized when a specific flowrate value is to be reproduced and the actual flowrate value plays a secondary role. In combination with viscous fluids this scale can be considered to be universal.

5 8S0U02 Fig. 2: Triflat Meter Tube Fig. : Bead Guide Meter Tube Fig. 3: Plain Taper Meter Tube 5

6 8S0U02 Specifications Meter Size and Flow Range Overview Meter Meter Tube Size Size / / / /8 / / / / 3/ 3/ / / p ) bezogen auf 0 03 mbar Min. Flow Range Max. Flow Range l/h Water m 3 /h ir ) l/h Water m 3 /h ir ) 0,00029bis 0,0029 0, bis, 0,0022 bis 0,022 bis 0 0,0223 bis 0,223 3 bis 32 0,003 bis 0,03 0,037 bis 0,37 0,7 bis,7 bis 3 bis 30 bis bis bis 800 bis ,3 bis,3 0, bis,3 0,9 bis 9,2,7 bis 7,3 bis 2,6 bis 0 5 bis 9 30 bis 300 bis bis bis bis ,00 bis 0,0 0,033 bis 0,33 0, bis,03,8 bis,3 3,8 bis 38,7 bis 83,0 bis,5 5 bis 285, 00 bis 50 rei-rippen-messrohre Meter Tube Size / 3/ / Max. Flowrate Meter Tube Float Pressure H 2 O ir (Qn) esignation Part No. esignation Part No. l/h 03 mbar rop 0, m 3 /h mbar ) 0 ) 36 ) ) 232 ) 2 0 8* * * 6 9* * * * * 3, ),0 ),3,7 5,5 ) 6,0 6,9 ) 7,0 7,5 8,0 0,3,3* 3,2 7,3 8,2 2,3* 2,0 26,0 29,5* 3, 38,7* 3,8,9 2,2,3 50,8 59,0 6,0* 67, 7,5 83,0* 90,2 0, 08,0 8, 37,8,5 80, 20,0* 236,2 7,0 285,* FP-/2 7-G-0/ FP-3/ 2-G-0/ FP-- -G-0/80 FP- /2--G-0/80 FP-2- -G-0/ _ _ 6000 _ 5000 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ /2-GSVT-5 /2-GSVT-5 /2-GSVT- /2-GSVT-8 /2-GSVT-5 /2-GSVT-8 /2-GNSVT-5 /2-GNSVT- /2-GSVT- /2-GSVT-8 /2-GNSVT-8 /2-GNSVT-3 3/-GSVT-5 3/-GNSVT-5 3/-GSVT-5 3/GSVT-53 3/-GNSVT-5 3/-GSVT-56 3/-GSVT-53 3/-GNSVT-56 3/-GNSVT-53 -GSVT-6 -GSVT-65 -GNSVT-6 -GSVT-6 -GSVT-65 -GNSVT-6 -GSVT-63 -GNSVT-65 -GSVT-66 -GNSVT-63 /2-GSVT-8 /2-GSVT-85 /2-GSVT-83 /2-GNSVT-8 /2-GNSVT-85 /2-GNSVT-83 2-GSVT-9 2-GSVT-93 2-GNSVT-9 2-GNSVT-96 2-GNSVT B033 _ 603B033 _ 603B032 _ 603B03 _ 603B033 _ 603B03 _ 603B03 _ 603B02 _ 603B032 _ 603B03 _ 603B0 _ 603B0 _ _ _ _ _ _ _ _ _ 6030 _ _ _ _ _ _ _ _ _ _ 6030 _ 603E032 _ 603E033 _ 603E03 _ 603E02 _ 603E03 _ 603E0 _ 603F032 _ 603F03 _ 603F02 _ 603F03 _ 603F0 _ 5,5 5,5,5,0 6,,0 2,0 9,,8 3,2,7,8 9,7,0,2 28,3 37, 23,0 33,5,7 0,9 9,3 2,6 29,6 28,2 36, 2,2 6,0 55, 72,2 87,5 22,3,0 3,9 26, 30,0 37,6 3,5 7,5,2 57, 62,0 VI 2) 5, 5, 7, 7,8 5, 7,8,0, 7, 7,6,,3 0,,6 0,,8,6,9,8 2,2 2,5,8 7,5 2,2,8,9 2,2,8 2,5 8,5 2,9,6 33,0 33,0,2 5,0,9 26,5 9,0 6, 3,3 7,3 Min. Pressure Required for Gas Metering bar 3),3 0,8,2,3 0,6,8 0,6 2,3,2,3,3,9 0,9 0,9 0,7 2,5 0,7,,8,,8 0,8, 0,8 0,5 0,6 0,5,0 0,6,0 0,9,,6,5,,6,5,2,7,2,5,7 6

7 8S0U02 Triflat Meter Tubes (Ball Floats) Housing Meter Max. Flowrate ) Meter Tube Float Size Tube H 2 O ir (Qn) esignation Part No. esignation Part No. Size cm 3 /min 03 mbar / / /8 / 0,53 0,92,6 2,5,05,58 3,2,82 2,6,2 7,2 0,3,7 7,6,3 7,8 5, 8, 3,5 8,6 6, 3,9 22,6 3,5 3,7 0,5 23,0,7 8,5 6,5,5 39,5 60,0 8,0 07,0 33,6 6,2 90,6,7 59,7 36,5 66,0 97,5 30,0 7, , cm 3 /min 8, 80,0 3, 92,5 73,2 7,0 88,6 0, 36,0 3,5 39,2 30,5 27,9 307, 75,3 636,2 23,2 326,7 508,5 678,0 373,6 696,3 06,2 6,6 885, 5,3 928,8 38,7 857,6 25,0 80,, 92,8 88,3 3629, 5,7 89, 30,3 3997,8 536,7 87,9 229,0 32, 229,3 556, FP-/-0-G-5/_ FP-/-0-G-5/_ FP-/-0-G-5/_ FP-/-0-G-5/_ FP-/-0-G-5/_ FP-/8-08-G-5/_ FP-/8-08-G-5/_ FP-/8-08-G-5/_ FP-/8-08-G-5/_ FP-/8-08-G-5/_ FP-/- 0-G-5/_ FP-/- 0-G-5/_ FP-/- 0-G-5/_ FP-/- 0-G-5/_ FP-/- 0-G-5/_ FP-/- 0-G-6/ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6000 _ _ _ 6000 _ _ 6000 _ _ _ 6000 _ _ 6000 _ _ _ 6000 _ _ 6000 _ _ _ 6000 _ _ 6000 _ _ _ 6000 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6000 _ 6000 _ 6000 _ BG- S- SS- - T- BG-8 S-8 SS-8-8 T-8 - S- SS- - T- SS- - T- 303F00U3 303F00U 303F00U0 303F00U5 303F00U09 303F002U3 303F002U 303F002U0 303F002U5 303F002U09 303F003U 303F003U 303F003U0 303F003U5 303F003U09 303F003U0 303F003U5 303F003U09 7

8 8S0U02 Bead Guide Meter Tubes (Floats with Low Pressure rop)+ Size Max. Flowrate Meter Tube Float Pressure H 2 O ir (Qn) esignation Part No. esignation Part No. l/h 03 mbar rop 0, m 3 /h mbarr ) 3 53 / / / *,3,6,8 2, 2,2 2,9,3 5,8 7,7 9,2 0,,8 3,8 5, 9,8 2,6,6 22,5 29,7 58,5* 2,6 05,0 FP-/2-7-G-0/ FP-3/- 2-G-9/80 FP-- -G-0/80 FP- /2--G-0/80 FP-2- -G-0/ _ _ 6000 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ /2-GUSVT-0 /2-GUSVT-0 /2-GUSVT-0 /2-GUSVT-0 /2-GUSVT-0 /2-GUSVT-0 3/-GUSVT-50 3/-GUSVT-50 3/-GUSVT-599 -GUSVT-6 -GUSVT-62 -GUSVT-6 -GUSVT-62 -GUSVT-60 -GUSVT-60 -GUSVT-60 -GUSVT B3 _ 603B3 _ 603B3 _ 603B3 _ 603B3 _ 603B3 _ 6033 _ 6033 _ 6033 _ _ _ _ _ 6033 _ 6033 _ 6033 _ 6033 _ /2-GUSVT E3 _ /2-GUSVT E33 _ /2-GUSVT E3 _ 2-GUSVT-93 2-GUSVT-9 603F3 _ 603F3 _,3, 2,0 2,0 2, 2,0,,9 2,0 2,7 2,7,0,0 8,7,2 8,7,6 3,2 3,7 5,5 3, 9,0 Glattkonische Messrohre (Führung des Schwebekörpers durch Führungsstange [P]) Size Max. Flowrate Meter Tube Float Pressure H 2 O ir (Qn) esignation Part No. esignation Part No. l/h 03 mbar rop 0, m 3 /h mbar ) / 3/ + / * * 58 6* 8* * 2330* 2670* * * * * Table 087/3 2,8,2 5,2 7,3* 7,9 0,8* 3,7 8,6* 2,5* 3,2 6,8 5,0* 69,9* 80,* 08,6 6,7* 50,0,6* 0,0 360,0* 38,0 50,0* FP-/2-9-P-0/ FP-3/- 7-P-0/ FP-- -P-0/80 FP- /2--P-0/80 FP-2-37-P-0/ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ /2-SVP--5 /2-SVP--5 /2-SVP-- /2-SVP--3 /2-SVP-- /2-SVP--3 3/-SVP-5-3/-SVP-5-3 3/-NSVP-5-3 -SVP-6- -NSVP-6- -SVP-6-2 -NSVP-6-2 -NSVP-6-603B3 _ 603B3 _ 603B _ 603B _ 603B _ 603B _ 603 _ 603 _ 603 _ 6033 _ 6033 _ 603 _ 6032 _ 603 _ /2-SVP-8-603E _ /2-SVP E _ /2-NSVP-8-603E2 _ /2-NSVP E _ 2-SVP-9-2-SVP NSVP-9-2-NSVP F _ 603F _ 603F2 _ 603F _,0,0 0,6 2,0 0,6 2,0 3, 23,5 2,2 2,0 3,6 5,0 67,3,6,7 3,9 36,6 57, 63,2 08, 06,7 70,3 VI 2) 2,2 2,2 2,9 2,9 2,2 2,9 3,3 3,3,5,0,2,0,2 6,0 8,6 6,0 8,6 6, 7,0,2 8,9 22,0 VI 2) 3,6 3,6 6,6 9, 6,6 9,,2, 2,,0 2,5 8,5,5,2 30,7 39,9,5 6,0 2,7 6,0 5,5 8,2 Min. Pressure Required for Gas Metering ρbar (bar) 3) 0,26 0,26 0,0 0, 0,26 0,2 0,23 0, 0, 0, 0, 0, 0, 0, 0,0 0,5 0, 0, 0,,0 0,,0 Min. Pressure Required for Gas Metering ρbar (bar) 3) 0,6 0,,0 3,,3 2,69,6 2,79 2,79,3,3 2,3 2,3 3,8,39 2,,39 2,,07,8,07,8 * Flow range < :.5 + Only available for sizes /P and F with larm Signal Transmitter 55X000. U0 U02 U03 U0 Scale esign ecal %-Scale ecal d.a.-scale ecal mm-scale ecal k/s-scale Float-Material The listed max. flowrate is based on a stainless steel float. Floats made of other materials are available. Their max. flowrate values may be different. ) Total pressure drop with a stainless steel float. 2) The Viscosity Immunity eiling VI is the upper limit for the viscosity of the liquid to be metered. The flowrate value values are not affected if the viscosity of the fluid in mpa s VUZ ρ. If the VI number is exceeded, the flowrate values may be affected resulting in a scale shift. Please contact the factory for such applications.. 3) These Meter Tube-Float combinations are not recommended for gas service if the upstream pressure p abs in bar is less than the value listed in the table. For low upstream or low operating pressures, the meter tube - float combinations listed in Table 087/3 are to be used or contact factory. U05 U06 U07 U08 U09 Engraved %-Scale Engraved d.a.-scale Engraved mm-scale Engraved k/s-scale without Scale 8

9 8S0U02 imensions SW SW2 B Mod. 087 Size B ø SW SW 2 Weight kg / / 3/ ,5 / Note: SW = Wrench size SW 8 SW SW 3 SW 38 SW 53 SW 66 SW 32 SW 6 SW 55 SW 65 SW 85 SW 05 0,6, 2,2 2,9,7 6,8 / 0,0 E Mod. 095 Size E B / G / 3/ G 3/ ,5 G / / Upon request B Fig. 5: imensions 9

10 8S0U02 Mod. 097 (P) Meter Tube Size Threaded onnection Wrench Size ± B SW / //8 // / 3/ / G / G /2 G 3/ G G /2 G , Weight approx. kg 0,5,7 2,3 2,7, 6,5 Mod. 097(V) Meter Tube Size onnections per IN 85 IN 05 Part / 3/ / B Threaded onnections , Rd 3 x /8 Rd x /6 Rd 52 x /6 Rd 65 x /6 Rd 78 x /6 S 5 S S S 0 S 50 Weight approx. kg ,7 2,3 2,7, 6,5 Mod. 098 (P) Meter Tube Size / //8 / / / 3/ / Flange onnections per IN 0 N PN k No. of Holes NSI - rilled for L 300 d2 N k No. of Holes 8 8 / / 3/ / 95,2 95,2 7,5 3,8 56,6 5, 66,7 66,7 82,6 88,9,3,0 8 d2 ± B Weight approx. kg 5,9 5,9 9,0 9,0 22,5 9, , , 2, 3,5,7 7,5 0,0 Fig. 6: imensions 0

11 8S0U02 larm Signal Transmitter for Glass Tube Flowmeters 55X000 pplication The larm Signal Transmitter includes one or two limit switches, (inert gas switches) which are actuated by a magnet embedded in the float. It is used in conjunction with the float designs G(N)SVT, (N)SVP and BL. (Please observe the footnotes in the Flow Range tables). Operation The larm Signal Transmitter is positioned in a guide slot in the flowmeter housing and can be adjusted over the entire flow range. The inert gas switches are configured as bistable contacts. The signal from the lower alarm is initiated when the float drops below the lower alarm switch position. The contact is closed. The signal from the upper alarm is initiated when the float travels above the upper switch position. The contact is closed. The circuits (between the alarm switches and the transistorized Switch mplifier WE 77) are intrinsically safe. The Switch mplifier must, however, be installed outside of the Ex-Zone. Specifications larm Switch Transmitter Inert gas switch (reed contact) Switch Type Bistable ontact onfiguration Lower alarm value: ontact opens for a rising float Upper alarm value: ontact closes for a rising float Power Max. 0 V, max. 8 V, 50/60 Hz onnection able LIFYY 2x0. able Length.75 m Protection lass per IN 0050 IP 65 llow. mbient Temperature -0 to +80 Switch mplifier (Ex) KF_SR2-ExW: for alarm switch KF_SR2-Ex2W: for 2 alarm switches Fig. 7: Supply Power 230 V +0 %, -5 %; 5-60 Hz 5 V +0 %, -5 %; 5-60 Hz Output or 2 switch relays with potential free contacts Power Max. 0 V, max., max. 500 V Max. allow. able Length Switch mplifier/ larm Signal Transmitter: 300 m ontrol ircuit (Ex)iG5 Zone 0 ertificate of ompliance Ex PTB 79/3X J k 3 m, J knenn = 8 m U o 3,5 V-, J onenn = 8 V- I a 3 m a 609 nf i 7 µf llow. mbient Temperature - to +60

12 8S0U02 larm Signal Transmitter for Glass Tube Flowmeters 55X000 Materials, onnections, Weights Ordering Information larm Switch Nickel plated brass Housing Polyamide Electrical onnections Screw terminals Weight approx. 0.7 kg Instrument Name, Ordering Number Ordering Number larm Signals Max. Min. Max. and Min. Switch mplifier Without -chanel 2-chanels Supply Power Withput 5 V, +0 %, -5 %, 5-60 Hz 230 V, +0 %, -5 %, 5-60 Hz Others esign Level pplications Model 087, X F

13 8S0U02 Needle Valves for Series 087 and 097 pplication Installed separately in the pipeline up- or downstream from the flowmeter. esign Female threaded connections pplication Installed separately in the pipeline up- or downstream from the flowmeter. esign Female threaded connections esign Features Material: Brass, PN 00, Max. 00 In-line valve fitting Good adjustability Specifications Part No Part No for O 2 pplication 00U0 00U02 00U03 00U0 Note: SW = Wrench size imensions N E SW G / G /2 G 3/ G , esign Features Material: SS 3Ti [No..57], PN 0, Max. 0 In-line valve fitting Good adjustability Specifications Part No imensions N B E G / G /2 G 3/ G U02 / NPT U0 3/8 NPT U03 / NPT N N B E SW E Fig. 8: Fig. 9: 3

14 8S0U02 Orderíng Information 087, Threaded onnections with ouplings Please include the Meter Name, Model No., flow range, fluid, density and viscosity at operating temperature, operating and max. pressure, operating and max. temperature, scale design: e.g. % or direct reading in l/h m 3 /Min or as desired. Ordering Number 087 onnection Type Flanges vertical esign Level Meter esign Standard WIth pole guide larm Signal Transmitter Without Suitable for later addition Fitting Material PV PVF Steel SS3TI No..57 onnection Material, In-/Outlet *See ttachment Burst Protection Without With Materials O-Rings Viton Ethylene-Propylene Buna N Siliconc Meter onnections Threaded couplings 3 Meter Tube SizeThreads (Gi) / / / /2 3/ 3/ / /2 2 / / /8 / ccuracy Standard alibration Viscosity calculation % of max. Instrument Tag German English P 0 F S T X 0 F N S B E

15 8S0U02 eríng Information 095/97, Threaded onnections Vertical / Horicontal Please include the Meter Name, Model No., flow range, fluid, density and viscosity at operating temperature, operating and max. pressure, operating and max. temperature, scale design: e.g. % or direct reading in l/h m 3 /Min or as desired. Ordering Number 09 onnection Type Threaded horizontal (upon request) Threaded vertical esign Level Meter esign Standard With pole guide larm Signal Transmitter Without Suibtale for later addition Fitting Material PV PVF Steel SS3Ti No..57 onnection Material, In-/Outlet *See ttachment Installation Method Pipeline mounting / without Pipeline mounting with Burst Protection Panel mounting Panel mounting with Burst Protection Material O-Rings Viton Ethylene-Propylene Buna N Silicone Meter onnections Pipe threads Threads per IN 85 NPT-Threads Meter Tube Size Threads (Gi) 85 / / - / /2 S 5 3/ 3/ S S / /2 S 0 2 S 50 / / - /8 / - ccuracy Standard alibration Viscosity calculation 3 % of max. Instrument Tag German English 5 7 P 0 F S T X F N S B E 5

16 8S0U02 Orderíng Information 098, Flange onnections Please also include the Meter Name, Model No., flow range, fluid, density and viscosity at operating temperature, operating and max. pressure, operating and max. temperature, scale design: e.g. % or direct reading in l/h m 3 /Min or as desired. Ordering Number 098 onnection Type Flanged vertical esign Level Meter esign Standard With pole guide larm Signal Transmitter Without Suitable for later addition Fitting Material PV PVF Steel SS 3Ti [No..57] onnection Material, In-/Outlet *See ttachment Burst Protection Without With Material O-Rings Viton Ethylene-Propylene Buna N Silicone Meter onnections Flanges IN 0 PN 0 ( / and = PN ) Flanges NSI L 300 (upon request) Flanges NSI L 50 Meter Tube Size N NSI / N 0 / / N 5 / 3/ N 3/ N / N 0 / N 50 / N 0 / /8 N 0 / ccuracy Standard alibration Viscosity calculation % of max. Instrument Tag German English P 0 F S T X 0 F N S B E The Industrial IT wordmark and all mentioned product names in the form XXXXXX IT are registered or pending trademarks of BB. BB has Sales & ustomer Support expertise in over 00 countries worldwide. The ompany s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (.02) BB 02 8S0U02 Rev. 02 BB Ltd. Oldends Lane, Stonehouse Gloucestershire, GL 0 3T UK Phone: +(0) Fax: +(0) BB Inc. E. ounty Line Road Warminster, P 897 US Phone: Fax: BB utomation Products GmbH ransfelder Str Göttingen GERMNY Phone: Fax:

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership Data sheet DS/6/6EN Rev. K Models 600 & 600 Purgemaster SNP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength stainless steel body the body is corrosion

More information

Scales: (Inches) Nominal Length Type and Location. Percentage on tube or Direct Reading on external metal scale with blank tube

Scales: (Inches) Nominal Length Type and Location. Percentage on tube or Direct Reading on external metal scale with blank tube Data Sheet D-FV-10A4600-_ Field IT Variable Area Flowmeters VA Master Indicating Fittings 10A4600- n Rugged body design with all type 300 stainless steel construction. n n n n Metering tube can be removed

More information

10A4500 / 10A4600 VA Master TM Indicating Flowrator

10A4500 / 10A4600 VA Master TM Indicating Flowrator Data sheet DS/0A4500 EN Rev. B 0A4500 / 0A4600 VA Master TM Indicating Flowrator The measurement solution for visual flow indication Measurement made easy Rugged, high-strength stainless steel body Suited

More information

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview Overview Design and operation The main components of the Tubux variable area meters are the glass variable-area flow tube with float, the fitting and the connection parts. The flow is displayed directly

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through

More information

Sho-Rate TM Models 1250 & 1255

Sho-Rate TM Models 1250 & 1255 DS-VA-1250-55-Series-eng May, 2017 Data Sheet Sho-Rate TM Models 1250 & 1255 Sho-Rate TM 1250/55 Series Ships in 3 days Overview Product Features es Variable Area Low Flow Glass Tube Flowmeters Series

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet

More information

Product Features: An excellent solution for measurement of flowrate for water, air and nitrogen.

Product Features: An excellent solution for measurement of flowrate for water, air and nitrogen. P270 Series crylic Tube Variable rea Flowmeter The P270 Series Flowmeters with molded construction are ideal for low flow rates of water, air and nitrogen in OEM applications. The P270 flowmeter is highly

More information

Sho-Rate TM Models 1250 & 1255

Sho-Rate TM Models 1250 & 1255 DS-VA-1250-55-Series-eng-GR July, 2017 Data Sheet Sho-Rate TM Models 1250 & 1255 Sho-Rate TM 1250/55 Series Overview Product Features es Variable Area Low Flow Glass Tube Flowmeters Series 1250/55 are

More information

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS ORIFICE PLATE FLOW INDICATOR U6 SERIE - Mounting in all positions - Construction: cast iron or stainless steel - For pipes from ND 40 up to ND 300 mm - Scale amplification from 2 to 10 - Accuracy: ± 2.5

More information

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4

ACCESSORIES LS/520, LC/520 Heavy duty non-return valves 1/ LT1000 Block form flow regulators (uni-directional) 1/8 & 1/4 ESSORIES LT000 lock form flow regulators (uni-directional) /8 & /4 LT00 lock form flow regulators (bi-directional) /8 & /4 LT70 Quick exhaust valves /8 & /4 LS/50, L/50 Heavy duty non-return valves /4...

More information

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Models 1350G & 1355G. Low Flow Glass Tube Flowmeters. Ships in 5 days. Overview. Product Features. Variable Area

Models 1350G & 1355G. Low Flow Glass Tube Flowmeters. Ships in 5 days. Overview. Product Features. Variable Area DS-VA-1350G-eng December, 2017 Data Sheet Sho-Rate TM Models 1350G & 1355G Sho-Rate TM 1350G & 1355G Series Ships in 5 days Overview Variable Area Low Flow Glass Tube Flowmeters The Brooks Sho-Rate TM

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

VARIABLE AREA FLOWMETER EASYFLOW.

VARIABLE AREA FLOWMETER EASYFLOW. VARIABLE AREA FLOWMETER EASYFLOW www.sedflowcontrol.com EASYFLOW APPLICATIONS Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment Plant Reverse Osmosis System Water

More information

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information:

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information: P430 Series Glass Tube Variable Area Flow Meter Parker P Series glass tube flowmeters deliver unsurpassed performance and value in a wide variety of gas and liquid applications. P430 Series flow meters

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

Contrans P Transmitter. Integral Orifice Assembly / EN. Measuring section for the measurement of small flow quantities

Contrans P Transmitter. Integral Orifice Assembly / EN. Measuring section for the measurement of small flow quantities Contrans P Transmitter Integral Orifice Assembly Measuring section for the measurement of small flow quantities 10/ 1460.BMP Measuring Media: Liquids, Gases (Vapors) Flow Measurement from 1.5 l/h (at =

More information

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water

More information

Float Flow Meters series NF

Float Flow Meters series NF Float Flow Meters series NF - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small dimensions Doc. no.: 22, en_cat_nf, 8/2015 Usage Flowmeters type NF are

More information

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. CATALOG Variable Area Flowmeter EASYFLOW www.sedflowcontrol.com SMART IN FLOW CONTROL. Easyflow Applications Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

Flow measurement of Liquids and Gases

Flow measurement of Liquids and Gases Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Diaphragm pressure gauge

Diaphragm pressure gauge Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety

More information

BI-METAL DIAL THERMOMETERS

BI-METAL DIAL THERMOMETERS T +6 (4) 2231 0059 F +6 (4) 2236 0236 Rm. 103-A, No. 67, T +6 (21) 5777 310 F +6 (21) 5777 319 BI-METAL DIAL THERMOMETERS 2. Case Dial 4. Connec on 5. Stem Dial 6. Stem Length 60 70 0 90 R 1 50 40 32 F

More information

Spare List SPL/266XXX-EN Rev. B. Models 266XXX spare parts list. 2600T Series Pressure Transmitters Engineered solutions for all applications

Spare List SPL/266XXX-EN Rev. B. Models 266XXX spare parts list. 2600T Series Pressure Transmitters Engineered solutions for all applications Spare List SPL/266XXX-EN Rev. B Models 266XXX spare parts list 2600T Series Pressure Transmitters Engineered solutions for all applications Models 266XXH DP style transmitter with barrel housing 6 0 9

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application: SI-02 Electromagnetic Flowmeter for General Applications Description: Features / Universally applicable / Separate or compact measuring transmitter / Variety of lining material / DN15 to DN2000 / DIN-

More information

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h... All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:

More information

02V11/04. Thermostatic Control Valve. B Valve. Key benefits. Typical applications

02V11/04. Thermostatic Control Valve. B Valve. Key benefits. Typical applications 02V11/04 Thermostatic ontrol Valve Valve Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications

More information

BROOKS 1350G & 1355G Glass Tube Variable Area Flowmeters. Low Flow, 65 & 150 mm Tubes, Optional Constant Diff. Pressure Regulators

BROOKS 1350G & 1355G Glass Tube Variable Area Flowmeters. Low Flow, 65 & 150 mm Tubes, Optional Constant Diff. Pressure Regulators www.clarksol.com BROOKS 1350G & 1355G Glass Tube Variable Area Flowmeters Low Flow, 65 & 150 mm Tubes, Optional Constant Diff. Pressure Regulators DESCRIPTION The Brooks Sho-Rate TM 1350 & 1355 Series

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

VLM10 In-line Vortex Mass Flow Meter

VLM10 In-line Vortex Mass Flow Meter VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process

More information

DMH. Magnetic Inductive Flowmeter. for conductive fluids

DMH. Magnetic Inductive Flowmeter. for conductive fluids Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C Connection:

More information

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0. Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O

More information

Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E

Sho-Rate TM 50 Model 1350E and Sho-Rate TM 150 Model 1355E Data Sheet Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E Ten-to-one rangeability Heavy-wall, precision bore, borosilicate glass metering tubes A wide range of scales on the metering tube

More information

Averaging PITOT Tube 5RD series

Averaging PITOT Tube 5RD series Averaging PITOT Tube 5RD series Pipe Drift for flow measurement : Inner pipe diameter Ø50 to Ø1500mm : Zero drift for better long-term stability Type of fluid Process pressure : Liquid, gas or steam :

More information

Gilflo ILVA flowmeters for steam, liquids and gases

Gilflo ILVA flowmeters for steam, liquids and gases Gilflo ILVA flowmeters for steam, liquids and gases The Gilflo in-line variable area (ILVA) flowmeter... is a revolutionary development of the well established family of Gilflo flowmeters that has been

More information

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 ) PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and

More information

LIQUID METER TYPE FMO

LIQUID METER TYPE FMO LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They

More information

Averaging PITOT Tube 5RD series

Averaging PITOT Tube 5RD series Averaging PITOT Tube 5RD series Pipe Drift for flow measurement : Inner pipe diameter Ø50 to Ø1500mm : Zero drift for better long-term stability Type of fluid Process pressure : Liquid, gas or steam :

More information

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long

More information

Variable Area Flowmeters Model 28

Variable Area Flowmeters Model 28 Variable Area Flowmeters Model 28 Model 28 Series high capacity flowmeters offer a means of measuring gas greater than our other variable area flowmeters. They are suitable for both plant and laboratory

More information

Data Sheet 102/103, 202/203, 302/303 Flanged Diaphragm Seal

Data Sheet 102/103, 202/203, 302/303 Flanged Diaphragm Seal FETURES thin PTFE gasket between the diaphragm/bottom housing ensures a leak-tight, corrosion resistant seal ontinuous duty design prevents loss of process fluid if pressure instrument is removed or fails

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data

More information

Field IT Coriolis Mass Flowmeter FCM2000

Field IT Coriolis Mass Flowmeter FCM2000 Data Sheet Field IT Coriolis Mass Flowmeter Coriolis Mass Flowmeters are used for the measurement of the mass flow and density to the highest accuracy. The fluid need not be electrically conductive. No

More information

ALTOFLUX IFS 4000/4005

ALTOFLUX IFS 4000/4005 KROHNE 03/2002 7.02351.22.00 GR ALTOFLUX IFS 4000/4005... result of more than 40 years experience with electromagnetic flowmeters Liner made of KROHNE Teflon -PFA or other fluorines Dimensionally stable,

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE SIMPE, BUT REIABE BEST COST PERFORMANCE R-0 Series GASS TUBE FOWMETER GENERA R-0 is a glass tube type variable area flowmeter. The flow rate is indicated by the position of and the graduation engraved

More information

Diaphragm pressure gauge per EN 837-3,

Diaphragm pressure gauge per EN 837-3, Diaphragm pressure gauge per EN 837-3, chemical design, NS 100/160,Type series BA2 Features Diaphragm pressure gauge Nominal ranges -400 mbar to -1...24 bar, 0 25 mbar to 0 25 bar High quality case with

More information

TURBINE METER SERIES FMT-S

TURBINE METER SERIES FMT-S TURBIN MTR SRIS FMT-S The best way to predict the future is to create it Introduction Typical metrological characteristics 2 1.5 The FMT-S turbine meters are robust and designed to perform on the highest

More information

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

Datasheet Rev.4 Jan 2015 Orifice plate - Overview Datasheet Rev.4 Jan 2015 Orifice plate - Overview Orifice plate design based on ISO5167, BS1042, ASME.MFC.3M and ISO TR15377 :2007 industry standards Accuracy, repeatability and reliability of the flow

More information

Technical Data Body Construction Materials Aluminum, brass, steel, 303 or 316 stainless steel O-ring Materials

Technical Data Body Construction Materials Aluminum, brass, steel, 303 or 316 stainless steel O-ring Materials 200 Series 0 to 3000 psig heck Valves H200 Series 0 to 6000 psig heck Valves Features & enefits Quick opening/positive closing Provides a wide range of adaptability Large flow capacity The patented sealing

More information

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002 PRODUCT INFORMATION Model 14MX Flowmeter Functional Overview PI 14-1 Rev: 1 March 22 DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details),

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

DCV Wafer check valves

DCV Wafer check valves V Wafer check valves V wafer check valves to prevent reverse flow... The Spirax Sarco range of V wafer check valves provides an effective minimal maintenance free solution for the prevention of reverse

More information

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

Electromagnetic flowmeters. dg:   NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12 Electromagnetic flowmeters dg: www.oryana.com.ar NEW Sensor MUT EL DSENG 1/ Sensor MUT EL MUT EL sensors represent the state of the art of EUROMAG INTERNATIONAL production for water cycle and process applications.

More information

SERIES OVAL GEAR FLOWMETER MOGF

SERIES OVAL GEAR FLOWMETER MOGF SERIES OVAL GEAR FLOWMETER MOGF Fluidex series MOGF is a Positive Displacement Flow Meter with medium capacity. The meters have two rotating gears in oval-shape. A fixed amount of the liquid passes between

More information

Pitot tube Model FLC-APT-E, extractable version Model FLC-APT-F, fixed version

Pitot tube Model FLC-APT-E, extractable version Model FLC-APT-F, fixed version Flow measurement Pitot tube Model FLC-APT-E, extractable version Model FLC-APT-F, fixed version WIKA data sheet FL 10.05 FloTec Applications Oil production and refining Water treatment and distribution

More information

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Pressure Booster System. Hya-Eco VP. Type Series Booklet Pressure Booster System Hya-Eco VP Type Series Booklet Legal information/copyright Type Series Booklet Hya-Eco VP KSB Aktiengesellschaft Frankenthal All rights reserved. Contents provided herein must neither

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han

More information

KSE Certified for vapours, gases and liquids Corrosion-resistant PTFE/PFA TFM-PTFE bellows sealed Special design for chlorine plants

KSE Certified for vapours, gases and liquids Corrosion-resistant PTFE/PFA TFM-PTFE bellows sealed Special design for chlorine plants Richter Certified Chemical Safety Valves KSE Certified for vapours, gases and liquids Corrosion-resistant PTFE/PFA TFM-PTFE bellows sealed Special design for chlorine plants Safety in corrosive and high

More information

SITRANS P. Transmitters for absolute pressure. Introduction 1/16. Application

SITRANS P. Transmitters for absolute pressure. Introduction 1/16. Application SITRNS P Introduction K II series S series (7MF4, from pressure series) S series (7MF4, from differential pressure series Fig. /8 SITRNS P transmitters for absolute pressure with built-in analog indicator

More information

Model 140MX Flowmeter Functional Overview

Model 140MX Flowmeter Functional Overview A higher level of performance Model 14MX Flowmeter Functional Overview DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details), providing

More information

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications Force Pressure Temperature Switch Contact thermometer Bimetal- or Gas actuated thermometer - Inductive contacts - Sliding contacts - Snap action contact - Class 1 acc. to DIN EN 13190 - Optional with liquid

More information

Flow - sight glass, flap, ball

Flow - sight glass, flap, ball GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 System Flow Sight glass Flap Ball Evaluating Display Applications Visual flow

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

KRAL Volumeter - OMG Series Universal Flowmeters

KRAL Volumeter - OMG Series Universal Flowmeters KRAL Volumeter - OMG Series Universal Flowmeters OMG - Universal OMG Flowmeters for a Wide Range of Applications Operating Conditions and Materials Flow Range: 0.03 to 2000 gpm Max. Pressure: 3600 psi

More information

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact

More information

Zirconia Oxygen Analyzer

Zirconia Oxygen Analyzer Data Sheet SS/ZDT/GP_6. Zirconia Oxygen Analyzer High Temperature Version ZDT GP Series Cost-effective solution for high temperature applications NEMA 4X/IP66 protection reliable operation in demanding

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide

Turbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide Turbine Meter TRZ 0 PRODUCT INFORMATION Serving the Gas Industry Worldwide TURBINE METER TRZ 0 Methode of operation, Construction Methode of operation The TRZ 0 turbine meter is a flow meter suitable for

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

DML-Series. Pelton wheel flow meter

DML-Series. Pelton wheel flow meter DML-Series Pelton wheel flow meter Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and

More information

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates Data sheet DS/FPD510 EN IOMaster FPD510 Compact integral orifice flowmeter Low-cost measurement of small flowrates Compact flowmeter for small pipelines & flowrates available for pipe sizes 1 /2, 1 and

More information

VERIS Accelabar. Superior Flow Measurement Accuracy

VERIS Accelabar. Superior Flow Measurement Accuracy VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow

More information

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,

More information

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Pressure Booster System. Hya-Eco VP. Type Series Booklet Pressure Booster System ya-eco VP Type Series Booklet Legal information/copyright Type Series Booklet ya-eco VP All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

For highest levels of purity

For highest levels of purity For highest levels of purity Gas purification systems www.airliquide.de Individual gas purification... versatile, quick and clean Proven technology For several decades, Air Liquide has been offering you

More information

E Spray Drying. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

E Spray Drying. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN E Spray Drying Meeting the challenges of new WELCOME TO DELAVAN industries and NEW markets SECTION INDEX Special purpose nozzles for use in the Spray Drying industry covering a wide variety of products.

More information

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES Protecting pipeline components from damaging particles with minimal pressure drop FEATURES Body material - ASTM and/or ASME as permitted under boiler code and power piping code. Provides assurance of quality

More information

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

TEK-B AR 3800E. Multivariable Pressure Transmitter.   PRESSURE. Technology Solutions Technology Solutions TEK-B AR 3800E Multivariable Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Bar 3800E is an

More information

TOPAS PMG / PMH Hydraulic sensor Hot water

TOPAS PMG / PMH Hydraulic sensor Hot water TOPAS PMG / PMH Hydraulic sensor Hot water Applications The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Features Insensitive to turbulences

More information

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. průmyslová elektronika Capacitive level meters CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and

More information

Visual Level Indicators VLI

Visual Level Indicators VLI WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The

More information

Sho-Rate Models 1350G & 1355G

Sho-Rate Models 1350G & 1355G DS-VA-1350G-eng (September, 2014) Data Sheet TM Sho-Rate Models 1350G & 1355G Model 1350G & 1355G Sho-Rate TM Variable Area Purgemeters Sho-Rate TM 50 Model 1350G and Sho-Rate TM 150 Model 1355G Overview

More information

Diaphragm seal with threaded connection Threaded design Model

Diaphragm seal with threaded connection Threaded design Model Pressure Diaphragm seal with threaded connection Threaded design Model 990.10 WIKA data sheet DS 99.01 for further approvals see page 6 Applications For aggressive, hot, corrosive, environmentally hazardous

More information

LIQUID LEVEL SWITCHES

LIQUID LEVEL SWITCHES LIQUID LEVEL SWITCHES Our Liquid Level switches come in a number of sizes and materials for use in a variety of industrial applications and other end-user solutions. Every switch is sealed with our patented

More information

94020 Conservation Vent (Pressure & Vacuum) Features

94020 Conservation Vent (Pressure & Vacuum) Features The Shand & Jurs Model Conservation Vent is designed utilizing over 90 years of experience in producing high quality and dependable conservation fittings. Continued design improvements provide these vents

More information