CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

Size: px
Start display at page:

Download "CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL."

Transcription

1 CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

2 APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water Treatment Plant in the Automotive Industry Cooling water distribution system in a glass melting factory

3 VARIABLE AREA FLOW METERS These flowmeters operate according to the variable area principle, where a float is suspended in upward flowing media in a tapered plastic tube. The vertical position of the float within the metering tube depends on the flowrate of the media. The measuring range is usually 1:10 where the scale is uniformly graded on the measuring tube. The measured value is determined by the upper edge of the float and can be easily read on the scale. The rotameter is suitable for liquids and gases and it provides a cost effective solution for flow measurement in l/h, Nm³/h, %, or other units. On request double scales are also available, such as l/h and %. SED offers attractive components for contactless monitoring and automatic detection such as the Reed Contact Switch and especially, the measuring sensor for continuous data acquisition, programmable via touch panel. MAIN FEATURES Wide choice of measuring scales Wide choice of end connections Eight different diameters Five different tube lengths Three different plastic tube materials SS and PP float materials Special and double scales available Good level of accuracy with simple operation Easy to maintain Accessories Transmitter for the continuous contactless measurement acquisition Reed switch for contactless monitoring of measured values CLASSIFICATION liquid gas long short Tube material: PVC PA PSU INSTALLATION DETAILS When the flowmeter is used in a system provided with control valves, the following criteria must be observed: With liquid media, isolating or control valves may be mounted both upstream or downstream the flowmeter With gaseous media, control valves are recommended to be mounted downstream the flowmeter All control valves must be open slowly and gradually due to the high sensitivity fo the float to flow variations. Flowmeter must be mounted vertical VERSATILITY Metering tubes are available in Trogamid (PA), suitable for inert media, PVC and Polysulfone (PSU) suitable for many corrosive media. Male threads moulded onto the end of the metering tube are used for easy mounting of unions. Standard unions are in PVCU but others are available according to the different working conditions. The floats are available in Stainless Steel (AISI 316 Ti) and PP depending on flow medium and measuring range. All the flowmeters are equipped with minmax visual flow indicators fully adjustable. In addition, the flowmeters can be fitted with minmax flow switches or measuring sensor. When fitting the electrical accessories, a float with magnet must be installed in the flowmeter. 0

4 TECHNICAL DATA Diameter Range Materials Standards Type 700 d5 (3/4 ); d3 (1 ); d40 (1 1/4 ); d50 (1 ½ ); d63 ( ); d75 ( ½ ) Type 750 d16 (3/8 ); d0 (1/ ); d5 (3/4 ); d3 (1 ) Measuring tube Transparent PVCU; Trogamid (PA); Polysulfon (PSU) Float Stainless Steel (AISI 316 Ti); PP; Stainless Steel (AISI 316 Ti) + magnet; PP + magnet Union ends PVCU; PVCC; PPH; Stainless Steel (AISI 316 Ti); Malleable Iron Orings EPDM; FPM PVCU Solvent welding metric size according to: ISO 77, EN 145, DIN 8063 Parallel threads according to: UNI ISO 8/1, DIN 999, BS 1 Others available on request PVCC Solvent welding metric size according to: ISO 77, EN ISO PPH Socket fusion according to: DIN 1696 Stainless Steel (AISI 316 Ti) Parallel threads according to: UNI ISO 8/1, DIN 999, BS 1 Malleable Iron Parallel threads according to: UNI ISO 8/1, DIN 999, BS 1 Standard media* Maximum working pressure** Working temperature range** Standard and Approvals Water Hydrochloric Acid (HCl 30%) Sodium Hydroxide (NaOH 30%) Sodium Hydroxide (NaOH 50%) Air (0 C / 1013 mbar abs.) Transparent PVCU 10 bar (145 psi) with water up to 5 C (77 F) 1.5 bar ( psi) with water up to 60 C (140 F) Trogamid (PA) 10 bar (145 psi) with water up to 50 C (1 F) Polysulfon (PSU): 10 bar (145 psi) with water up to 70 C (158 F) 6 bar (87 psi) with water up to 100 C (1 F) Transparent PVCU from 5 C (41 F) to 60 C (140 F) Trogamid (PA) from 0 C (4 F) to 50 C (1 F) Polysulfon (PSU) from 0 C (4 F) to 100 C (1 F) Manufactured under ISO 9001 (Quality Management) Manufactured under ISO (Environmental Management) * Other media on request ** Depends on union end material (see Pressure / Temperature table for details page 4) VERSIONS Float material Water NaOH HCI Air PP PP + magnet (AISI 316 Ti) (AISI 316 Ti) + magnet PP air PP air + magnet Tube material PVCU Trogamid (PA) Polysulfone (PSU) 03

5 PRESSURE TEMPERATURE CORRELATION Temperature C Tube material Union material Operating pressure [bar] PVCU 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 PVCC 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 PVCU PP 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 Malleable Iron Stainless steel 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 PVCU 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 Trogamid (PA) PVCC 10,0 10,0 10,0 10,0 8,5 6,5 5,0 3,5 PP 10,0 10,0 10,0 10,0 8,5 7,0 5,5 4,0 Malleable Iron Stainless steel 15,0 15,0 15,0 15,0 15,0 15,0 15,0 13,5 1,0 10,7 9,5 15,0 15,0 15,0 15,0 15,0 15,0 15,0 13,5 1,0 10,7 9,5 PVCU 10,0 10,0 10,0 10,0 8,0 6,0 3,5 1,5 Polysulfon (PSU) PVCC 10,0 10,0 10,0 10,0 8,5 6,5 5,0 3,5,5 1,5 PP 10,0 10,0 10,0 10,0 10,0 8,5 7,0 5,5 4,0,7 1,5 0,8 Malleable Iron Stainless steel 15,0 15,0 15,0 15,0 15,0 15,0 15,0 14,0 13,0 1,0 11,0 9,7 8,5 7,7 6,0 15,0 15,0 15,0 15,0 15,0 15,0 15,0 14,0 13,0 1,0 11,0 9,7 8,5 7,7 6,0 TYPE 700 (LIQUID FLUID) PRESSURE LOSS Float Material Size d5 (3/4 ) DN0 d3 (1 ) DN5 d40 (1 1/4 ) DN3 d50 (1 1/ ) DN40 d63 ( ) DN50 d75 ( 1/ ) DN65 mbar PP PP + magnet (AISI 316 Ti) (AISI 316 Ti) + magnet TYPE 750 (LIQUID FLUID) PRESSURE LOSS Float Material Size d16 (3/8 )) DN10 d0 (1/ ) DN15 mbar d5 (3/4 ) DN0 d3 (1 ) DN5 PP PP + magnet (AISI 316 Ti) (AISI 316 Ti) + magnet

6 DIMENSIONS Type 700/701 Socket Threaded BSP Socket Tube lenght DN d R A (mm) B (mm) C (mm) E (mm) 0 5 3/ / / / Type 750/751 Socket Threaded BSP Socket Tube lenght DN d R A (mm) B (mm) C (mm) E (mm) / / / ACCURACY CLASS TYPE 700 Accuracy Class.5 Standard VDI/VDE 3513, sheet Accuracy ± 1.875% of reading % of full scale TYPE 750 Accuracy Class 4 Standard VDI/VDE 3513, sheet Accuracy ± 3% of reading + 1% of full scale 05

7 MEASURING RANGES FOR DIFFERENT FLOAT MATERIALS TYPE 700 LONG VERSION Float material: SS or SS + magnet Float material: PP or PP + magnet Nominal size Tube Water HO Hydrochloric acid HCl 30% Liquid fluid Sodium Hydroxide NaOH 30% Tube material PVCU PA PSU PVCU PSU d DN R Code Measuring Range [l/h] 5 0 3/ / / / 5 0 3/ / / Special scales on request / TYPE 701 LONG VERSION Float material: PP air and PP air + magnet Sodium Hydroxide NaOH 50% , , ,554 0,59, , , , Nominal size Tube Gases fluid Air bar abs. 0 C Tube material PA Measuring Range [Nm 3 /h] d DN R Code Float PP material: Float magnet material: PP 40 0,,5 0, /4 41 0, ,56,5 1, , , ,56,5 1, , , , / / , / on request Special scales on request 06

8 MEASURING RANGES FOR DIFFERENT FLOAT MATERIALS TYPE 750 SHORT VERSION Float material: SS or SS + magnet Float material: PP or PP + magnet Water HO Hydrochloric acid HCl 30% Liquid fluid Sodium Hydroxide NaOH 30% Nominal size Tube Tube material PVCU PA PVCU PSU PSU d DN R Code Measuring Range [l/h] / / 5 0 3/ / / 5 0 3/ Special scales on request TYPE 751 SHORT VERSION Float material: PP air and PP air + magnet Sodium Hydroxide NaOH 50% ,58,5 0,051, ,540 0, , ,537,5 0,56, , , ,515 1, ,53 0,050, ,5, ,545 0, ,5 0, ,55, ,563 0,51, , ,547, , , , Nominal size Tube Gases fluid Air bar abs. 0 C Tube material PA Measuring Range [Nm 3 /h] d DN R Code PP Float material: Float magnet material: PP 1 0,050,5 0,060, /8 0,040,4 0,11 3 0,11 0,5,5 4 0, 0,454,5 10 0,0450,45 0,11, 11 0,090,9 0, / ,151,5 0,5,5 0,353,5 0, ,383, ,44,8 1,51,5 0 0,11, 0,33 1 0,3,5 0, /4 0,454,5 1,1 3 0,66,5 1, ,111, , ,77 1,111 1,717, ,535 Special scales on request 07

9 PART LIST Description Material Quantity Transparent PVCU 5 1 Tube Trogamid (PA) 1 Polysulfon (PSU) 4 6 Adjustable visual flow indicator PVDF 7.1 3* Floater wing PVDF PVCU 4 Nut PVCC PP Stainless Steel Malleable Cast Iron PVCU PVCC 1 5 End connector PP Stainless Steel Malleable Cast Iron EPDM 6 ORing 7. FPM Upper float stop PVDF ** Lower float stop PVDF 1 Stainless Steel 5 8 Float 1 PP * For Code 68 only ** 7. for 700/701 only 08

10 ORDERING KEY A B C D E F G H Type Size Tube code Tube material Floater material Connection Oring material Fluid Pos. Description Code Specification A Type: See page / flowmeter type 700 flowmeter type 701 flowmeter type 750 flowmeter type 751 B Size: See page 3 DN 10, 15, 0, 5, 3, 40, 50, 65 F B C Tube: 1,, 3, Tube See page 67..., 68 D Tube material: 1 Trogamid Polysulfon C E See page 67 Floater 3 PVC Stainless steel material: 5 PP (weighted) M Stainless steel magnet See page 3 5M F Connection: 10 PPmagnet (weighted) PVC Standard plain socket 11 PVC BS plain socket 1 PVC ASTM plain socket 13 PVC threaded socket BSP 1 PP ISOwelding socket 31 PVDF ISOwelding socket CPVC Standard plain socket Stainless steel, union end with threaded A E socket G Oring 80 1 Malleable Iron EPDM (EthylenePropylene) D material: FPM (Viton) H Fluid: H O Water NaOH 30 Caustic soda 30% NaOH 50 Caustic soda 50% HCL 30 Hydrochloric acid 30% AIR Air Vnumber Special scale Specification required for special scale G Physical condition Fluid Absolute pressure in bar (for gases) Density Temperature in C Viscosity in mpas Measuring range 09

11 ACCESSORIES MEASURING SENSOR Measuring sensor for all types of variable area flowmeters suitable to be applied to liquids and gases. The measuring sensor provides a continuous signal of the flow throughout the complete measuring range. The sensor feels the floater position even with nontransparent or turbid media in the flowmeter EasyFlow. The continuous Position detection is carried out with several Magnetic field sensors over a length of up to 00mm. The measuring sensor is installed is via a modular mounting clip concept on all Easyflow standard types. Due to the product design, the scale remains visible on the flow tube of the attached sensors. The parameterization of the sensor is possible by pushing some capacitive buttons. Further possible settings concearn the activation of MIN/MAX indicator bar, the individual adjustment of the analog process signal (010V or 0/40mA) or the brightness of the LED bar display. With a 5pin M1. Connector as an electrical interface, a supply voltage of 4V DC and the device protection class IP67, the measuring sensor can be used in many areas of plant automation. FEATURES TECHNICAL DATA Modular mounting concept Visibility of scale and position of floater Capacitive touch buttons Electrical interface, M1 industrial connector Floater position visualized with LED row Floater position remains visible Power Supply Output Signal IPClass housing material mounting 4V DC 40mA/010V IP67 PPSU clips (many interfaces available) electrical connection multipol M1, 5 pin, acoded Type flowmeter ArticleCode 700/ / temperature C Power consumption Type 1,5 W Accuracy 1% CE EMV 004/108/EG Operation Floater position 3x capacitive touch keys visualized with 50/ xx LEDs 10

12 ACCESSORIES Variable area flow meter Measuring sensor

13 ACCESSORIES MICRO SWITCHES The micro switches are clamped on the guide of the flowmeter. A bistable reed contact is built into the switches and it is activated by the magnet incorporated into the float. The bistable magnetic micro switch is used as a position indicator for floats in SED flowmeters. Measurements can be expressed contactfree and nonreactive. The micro switches, with IP65 protection class, are available for MIN or MAX flow rate indication with a different design according to flowmeter sizes. MAX control switch /.055 It closes when the MAX threshold is overshot upward. 1 MIN control switch /.065 It closes when the MIN threshold is overshot downward. 1 CLASSIFICATION Type flowmeter ArticleCode 700/ /751 DN /751 DN Reduced hight on request Reduced hight on request

14 TECHNICAL DATA Body material Connection PP GRP DIN Protection rate IP65 Contact resistance 0.1 Ω Contact insulation from Ω resistance Closing time 1.1 msec. Opening time 0.05 msec. Working Temperature from 40 to +80 C Contact Material Ruthenium with inert protective gas Max operating power Max operating voltage 30 Watt 50 V DC/AC Max input peak 0.5 A Max current 0.5 A Standards CE conformity RoHS conformity Caution: Take care of max current otherwise you may destroy the contact DIMENSIONS

15

16 CATALOG Variable Area Flowmeter Easyflow SED Flow Control GmbH Am Schafbaum Bad Rappenau Telefon: Telefax: info@sedflowcontrol.com Internet: TD Rev.d, Subject to alteration SMART IN FLOW CONTROL.

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Float Flow Meters series NF

Float Flow Meters series NF Float Flow Meters series NF - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small dimensions Doc. no.: 22, en_cat_nf, 8/2015 Usage Flowmeters type NF are

More information

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE SIMPE, BUT REIABE BEST COST PERFORMANCE R-0 Series GASS TUBE FOWMETER GENERA R-0 is a glass tube type variable area flowmeter. The flow rate is indicated by the position of and the graduation engraved

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Flow Rate Transmitters/ Flow Switches

Flow Rate Transmitters/ Flow Switches Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

Target Inline Flowmeter

Target Inline Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

DIVA flowmeter. for saturated steam flow measurement

DIVA flowmeter. for saturated steam flow measurement DIVA flowmeter for saturated steam flow measurement DIVA the Direct In-line Variable Area flowmeter... Energy is often treated as an overhead but can represent a considerable part of the cost of production

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h... All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses Flowmeters QSE MAG FLOW METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation Systems Institutional Chilled

More information

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses Flowmeters QSE MAG FLOW METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation Systems Institutional Chilled

More information

Weir Valve Selections

Weir Valve Selections Unlined Metal Excellent Cvs Complete Selection of End Connections ASTM Materials Include: Cast Iron ASTM A-126 Class B Ductile Iron ASTM A-395 Grade 60-40-18 Cast Steel ASTM A-216 Grade WCB 316 Stainless

More information

KLINGER Ballostar KHE: This ball valve offers more

KLINGER Ballostar KHE: This ball valve offers more KLINGER Ballostar KHE Split body ball valve DN (1/2 ) 0 ( ) Edition 10 Tel. + (0)2252 600-0 Fax + (0)2252 600- Web: www.klinger.kfc.at KLINGER Ballostar KHE: This ball valve offers more The design of

More information

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3) pplication and Type PN pplication for liquids, gases and vapours Ø D 80 BB EN BB SME PN Class 150 suitable for heating, air-conditioning, water supply and cooling installations,for applications where minimum

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT SMART THINKING WATER ULTRIMIS W ULTRASONIC WATER METER DN15, DN20, D25 i DN32 MID R 800 AMR READY Ultrimis W a state-of-the-art ultrasonic water meter with the very latest patented design features including

More information

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1154 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10

More information

PVC-C metric Fittings

PVC-C metric Fittings Fittings 23 00 01 Ben 90, PVC-C Raius = 2 Raius = 2 PN Coe SP kg z 20 16 723 000 106 10 0.030 40 27 58 25 16 723 000 107 10 0.055 50 35 71 32 16 723 000 108 10 0.075 64 38 88 40 16 723 000 109-0.276 80

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Rosemount 1152 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment

More information

Thermocouple for Flue Gas Temperature Measurements,

Thermocouple for Flue Gas Temperature Measurements, Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment

More information

Visual Level Indicators VLI

Visual Level Indicators VLI WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The

More information

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014) ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014) WATER COOLING TOWER School of Bioprocess Engineering University Malaysia Perlis EXPERIMENT Water Cooling Tower 1.0 OBJECTIVES 1.1 To determine energy and

More information

Water Softener softliq:mc. Intended use. Function. Design

Water Softener softliq:mc. Intended use. Function. Design Subject to modifications TD2-BS000de_004 Edition May 2016 Intended use The water softener softliq:mc may only and exclusively be used for the softening and partial softening of cold drinking water. The

More information

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership Data sheet DS/6/6EN Rev. K Models 600 & 600 Purgemaster SNP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength stainless steel body the body is corrosion

More information

Close Coupled Sump Pumps Type ETLB

Close Coupled Sump Pumps Type ETLB Close Coupled Sump Pumps Type ETLB»dry running safe«technical data Flow rate Q up to 104 m 3 /h Head H up to 36 m Submersion depth up to 775 (795) mm Suction extension up to 1500 mm Materials limits of

More information

Ball Float Steam Trap UNA 38, PN 100/CL 600, DN UNA 39, PN 160/CL 900/CL 1500, DN 15-50

Ball Float Steam Trap UNA 38, PN 100/CL 600, DN UNA 39, PN 160/CL 900/CL 1500, DN 15-50 Data Sheet 88620-0 Issue Date: 0/7 Ball Float Steam Trap, PN 00/CL 600, DN 5-50, PN 60/CL 900/CL 500, DN 5-50 h Rear view Description UNA 3.. are steam traps with ball float and needle valve for high-pressure

More information

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02 Installation plan Tumble dryer PT 8807 EL (Electrically heated) 38.15 en - US Mat. NR. 09 883 210 / 02 U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: Fax: 800-991-9380

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

Pump down time for 5 l receiver

Pump down time for 5 l receiver INNOVATIVE TECHNOLOGY WORLDWIDE NEUBERGER Pump down time for 5 l receiver MODEL CODE FOR EASY ORDERING The model code is identical to the order number. It is made up as follows: N 85.3 KN E DC 230 V/50

More information

High Performance, Corrosive Handling Pleated Filters

High Performance, Corrosive Handling Pleated Filters High Performance, Corrosive Handling Pleated Filters WARCO FILTERS WARCO absolute rated filtration systems set the standard for demanding corrosive chemical process filters. WARCO highly engineered, glass-free

More information

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants Flow rate Q n 2.5... 25. Weatherproof: designed for the tough conditions outdoors.

More information

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1 Turbine Meter PTF Wide flow range up to :1 Intrinsically Safe and Flameproof versions available increases range of applications Excellent linearity and repeatability meets fiscal metering standards Linear

More information

b) General instructions and documents to be submitted by an interested company:

b) General instructions and documents to be submitted by an interested company: REFERENCE: EOI/675/2015 Date: July 23, 2015 Dear Sir / Madam, United Nations Development Programme in Belarus (UNDP) invites companies to submit Expressions of Interest in participating in the subsequent

More information

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems. PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and equipment support systems. B. Inserts. 1.02 RELATED SECTIONS A. Section 15890 - Ductwork Supports. 1.03 DEFINITIONS A. Supports: Attachments, hangers,

More information

Welding Force Calibration Transmitter

Welding Force Calibration Transmitter Force Welding Force Calibration Transmitter System for Measuring the Electrode Force in Spot Welding Type 9831C... Measuring system for testing and calibrating the electrode force in spot welding machines

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series 70-82-03-14 June 08 Page 1 of 8 Specification Main Overview The specification of an Electrolytic Conductivity Cell requires

More information

40PP Series Couplings

40PP Series Couplings Tubing Size 1/4-3/8 1/4 Flow Polypropylene 40PP Series Couplings 40PP Series couplings offer 1/4 flow and are produced from medical grade gamma sterilizable polypropylene. The 40PP Series polypropylene

More information

VERIS Accelabar. Superior Flow Measurement Accuracy

VERIS Accelabar. Superior Flow Measurement Accuracy VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow

More information

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

Protection classification IP 23

Protection classification IP 23 TIG 180 AC/DC puls 290-020200-00000 TEAMWELDER TIG 180 AC/DC the specialist for aluminium welding TIG and MMA welding Ideal for aluminium: Optimum ignition and stabilisation of the alternating current

More information

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved. PureFlex is a world leading manufacturer of high performance Fluoropolymer and Composite products and technologies. We specialize in the manufacturing of fluid handling and sealing products specifically

More information

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140 Technical Information TI 178C/07/en No. 5008898 Immersion Assembly for ph and Redox Sensors DipFit P CPA 10 Immersion assembly with flange connection for demanding processes. Sensor holder with bayonet

More information

PNEUMATIC RACK & PINION ACTUATORS

PNEUMATIC RACK & PINION ACTUATORS PNEUMATIC RACK & PINION ACTUATORS 90-120 - 180 ALPHAIR PNEUMATIC ACTUATORS 90 - STD Series 120 - Y Series 180 - X Series ALPHAIR pneumatic actuators are made by the best manufacture experience on design,

More information

AVK NEDERLAND INDUSTRIAL VALVES & FITTINGS MAKING A DIFFERENCE INDUSTRIAL 1

AVK NEDERLAND INDUSTRIAL VALVES & FITTINGS MAKING A DIFFERENCE INDUSTRIAL 1 AVK NEDERLAND INDUSTRIAL MAKING A DIFFERENCE INDUSTRIAL 1 AVK NEDERLAND INDUSTRIAL AVK Group The AVK Group is a privately owned industrial group that currently comprises 90 companies. AVK s core business

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet

More information

PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated check valve

PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated check valve Richter and -Way Sight Glasses PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated chec valve Richter and -way sight glasses

More information

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

Custom-Designed Clamps. Machined Versions.  Online Configurator for Custom-Designed Clamps A56. Custom-Designed Clamps Machined Versions Custom-designed clamping systems for pipes, tubes, hoses, cables and other components according to customer`s specifications or based on developments, made of thermoplastics,

More information

NEW MOBILITY IN MIG/MAG PULSED ARC TECHNOLOGY MEGAPULS 250

NEW MOBILITY IN MIG/MAG PULSED ARC TECHNOLOGY MEGAPULS 250 NEW MOBILITY IN MIG/MAG PULSED ARC TECHNOLOGY MEGAPULS 250 2 A powerful package portable and multi-functional Perfect for handcraft, medium sized companies and industrial use MEGAPULS 250 is a portable

More information

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION GENERAL DESCRIPTION The Orbinox model RB Weir Gate is designed for downward opening applications where a more accurate flow control is required. The water flows over the top of the slide permitting a constant

More information

Dorot Irrigation Meter

Dorot Irrigation Meter DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design

More information

Analytical Instruments

Analytical Instruments Smart Sensors Unique measurement technology Unique Innovations Honeywell is an industry proven leader for analytical products and solutions with unique technologies. Innovations in analytical measurements

More information

TEMPERATURE SWITCHES AND THERMOSTATS

TEMPERATURE SWITCHES AND THERMOSTATS TEMPERATURE SWITCHES AND THERMOSTATS Our temperature switches and thermostats are ideal for applications where the end user is looking for highly accurate control across a wide range of operating temperatures.

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Flanged Water Meters (non-continuous flow)

Flanged Water Meters (non-continuous flow) Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30

More information

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com Industrial Solutions Quality is Our Driving Force interfaceforce.com The high performance you ve come to know and trust from Interface products is also available in a rugged industrial configuration. Since

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :

More information

Over pressure Switching pressure difference (typical) Lower range Upper range

Over pressure Switching pressure difference (typical) Lower range Upper range Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold

More information

Flow and Pressure Capabilities

Flow and Pressure Capabilities Flow and Pressure Capabilities Industrial Sensing and Control Roxspur Measurement and Control Autorisierter Distributor: Neumüller Elektronik GmbH Gewerbegebiet Ost 7 D-91085 Weisendorf Tel. +49 9135 73666-0

More information

High Pressure Filter Assemblies

High Pressure Filter Assemblies High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than

More information

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01)

Pipe Joints. Requirements and Test Methods. VdS-Guidelines for water extinguishing systems. VdS en. VdS en : (01) VdS-Guidelines for water extinguishing systems VdS 2100-6en Requirements and Test Methods Reproduction prohibited even for internal use VdS 2100-6en : 2004-01 (01) Publisher and Publishing house: VdS Schadenverhütung

More information

Agilent 4339B/4349B High Resistance Meters Technical Overview

Agilent 4339B/4349B High Resistance Meters Technical Overview Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

VALVE PRODUCT OVERVIEW

VALVE PRODUCT OVERVIEW WATER MANAGEMENT VALVE PRODUCT OVERVIEW WATER MANAGEMENT Double Eccentric BFV DEX Main Specification Double Eccentric BFV DEX Model Body Disc Shaft Retaining ring Internal bolts External bolts Bearing

More information

FLOW MEASUREMENT Product Code 316 Instruction manual Contents

FLOW MEASUREMENT Product Code 316 Instruction manual Contents FLOW MEASUREMENT Product Code 316 Instruction manual Contents 1 Description 2 Specifications 3 Installation requirements 4 Installation Commissioning 5 Troubleshooting 6 Components used 7 Packing slip

More information

Glass Tube Flowmeter. Datenblatt 10A1190. Rugged and simple industrial instrument

Glass Tube Flowmeter. Datenblatt 10A1190. Rugged and simple industrial instrument atenblatt 8S0U02 Field IT Glass Tube Flowmeter Function Rugged and simple industrial instrument for metering the flow of liquids and gases. pplication reas Suitable for many industries including apparatus

More information

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available

More information

CONA -Universal ANSI / CONA -Connector ANSI

CONA -Universal ANSI / CONA -Connector ANSI CONA -Universal ANSI for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal ANSI / CONA -Connector ANSI CONA B-Universal ANSI Bimetallic steam trap ANSI CONA M-Universal

More information

FLOWRATE MEASURE PROBE DEBIX

FLOWRATE MEASURE PROBE DEBIX IX serie - For pipes: ND 15 up to ND 3000 - Very low pressure loss - Flow = (f) P - For liquids, gazs and steams - Permanent accuracy ± 1% - Excellent repeatability: 0.1 % - Proof against impurities -

More information

Turbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide

Turbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide Turbine Meter TRZ 0 PRODUCT INFORMATION Serving the Gas Industry Worldwide TURBINE METER TRZ 0 Methode of operation, Construction Methode of operation The TRZ 0 turbine meter is a flow meter suitable for

More information

6.1 General. This chapter shall provide requirements for correct use of sprinkler system components and hardware.

6.1 General. This chapter shall provide requirements for correct use of sprinkler system components and hardware. NFPA 13-Proposed 2013 Edition Standard for the Installation of Sprinkler Systems TIA Log No.: 1054 Reference: Chapter 6 Comment Closing Date: June 1, 2012 Submitter: Bob Caputo, Fire & Life Safety America

More information

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators ARI-STEVI 4 / 441 (DN15-0) Control valve - straight through With pneumatic and electric actuators ARI-STEVI 4 / 441 Pneumatic actuator ARI-DP 32-34 Tri Reversible pneumatic actuator Actuator with rolling

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 50 to 600 Flanges R.F. PN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN300 ( 10 bars over ) Specifications : Ductile iron disc All positions Low

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain instructions LORO direct balcony drains with connecting sleeve, EN 123-compliant, Steel, hot-dip galvanised, additionally coated, and DN 100 System overview for balcony storeys one-piece for upper balconies

More information

ASME B31.3 Process Piping. 19. What s Different in B31.1

ASME B31.3 Process Piping. 19. What s Different in B31.1 ASME B31.3 Process Piping Charles Becht IV, PhD, PE Don Frikken, PE Instructors BECHT ENGINEERING COMPANY, INC. What s Different in B31.1-1 19. What s Different in B31.1 Scope Organization of the Code

More information

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 13686.00 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529-1 SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 1.1 SUMMARY A. Section Includes: 1. Metal pipe hangers and supports.

More information

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1.

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1. Industrial Electrolytic Conductivity Cells Main Overview The specification of an Electrolytic Conductivity Cell requires careful consideration of the following factors: 1. Appropriate Cell Constant, determined

More information

Model B. Thermostatic Control Valves. Typical applications

Model B. Thermostatic Control Valves. Typical applications Thermostatic Control Valves Model B Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications

More information