R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

Size: px
Start display at page:

Download "R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE"

Transcription

1 SIMPE, BUT REIABE BEST COST PERFORMANCE R-0 Series GASS TUBE FOWMETER GENERA R-0 is a glass tube type variable area flowmeter. The flow rate is indicated by the position of and the graduation engraved on the glass tube. Although it has a very simple construction, it is widely used for measurement of flow rate of liquids and gases in various applications thanks to its high reliability and easy handling capability. R-700 series having alarm contact are also available. (Refer to separate TECHNICA GUIDANCE for details.) FEATURES DIRECT OBSERVATION OF FUID In addition to flow rate measurement, direct observation of fluid can be done through glass tube. This is effective for quality control of process line. COST EFFECTIVENESS This is the most cost effective device for local flow measurement. Very widely used for various applications. EASY INSTAATION No adjustment is required after installation. No straight run for upstream and downstream is needed. This results easy piping design. EASY MAINTENANCE Very simple construction offers almost "NO MAINTENANCE OAD". PURE MECHANICA CONSTRUCTION Flow rate is measured by pure mechanical action and no utility supply such as electric, air...required. MODE CODE R- Description 1 BOTTOM TOP 2 BOTTOM TOP SIDE Flow Direction 3 BOTTOM SIDE TOP SIDE BOTTOM SIDE TOP 5 BOTTOM REAR TOP REAR R RIBBED TAPERED TUBE Options V FOW ADJUSTING VAVE TG-F73-5E TG-F73-8E FEB. K MAR. 1K

2 R-0 Series GASS TUBE FOWMETER STANDARD MATERIA PRODUCTS OUTINE In STANDARD MATERIA PRODUCTS, the fluid contacting body material is cast iron and stainless steel. They are widely used for measurement of water, air and other "Not-so-corrosive" fluids. STANDARD SPECIFICATION Measuring fluid All kinds of liquids and gases (Not suitable for steam measurement. AM series Metal Tube Flowmenters are recommended.) Available to 0 () Process connection Standard JIS K flange Option ANSI, DIN, other flanges Rc, NPT (up to mm) DIMENSION R-1 R-2 R-3 R-5 A A Fluid pressure Max. Fluid press. (MPa) TOKYO KEISO CO., TD. 0 Max. Fluid press. (MPa) Max. thermal shock C Indication accuracy steel ±1.5%F.S. Resin ±2.5%F.S. Range ability :1 (±3% F.S. for liquids with QW of /h or lower, and gases with QN of 1.5 m 3 /h (nor) or lower) Available material Fittings Cast iron, SUS30, SUS316, SUS316 Tapered tube Heat-resistant glass (Acryl tapered tube is available on request.) For liquids SUS30, SUS316, SUS316, PVC, Others For gases Aluminium, PVC, PTFE, SUS30, Others rod SUS30, SUS316, SUS316, Others (The meters for gases with or more in meter and ones for liquids with or more have the rods) NBR, FPM, Others Paint Munsell 7.5BG /1.5 The parts made of stainless steel is not painted. Fluid temp Select the temperature for the material in the following table in the operating temperature limit. PRODUCT MASS Mass (approx.) (1) (2) 0 Above table shows the approximate mass of R-1 made of metal. 0 Dimension (mm) A (mm) Refer to the flow rating by in the next page. Mass (approx.) TG-F73-8E

3 R-0 Series GASS TUBE FOWMETER CAPACITY RATING For liquid measurement For gas measurement (1) (2) 0 Water flow [/h] Glass tapered tube Acryl tapered tube steel 9 to PVC, PTFE 30 to steel 70 to PVC, PTFE 30 to (1) (2) 0 steel 12 to Air flow [m 3 /h (nor)] Glass tapered tube Aluminum PTFE 0.18 to Acryl tapered tube steel Aluminum 0. to to to FOW RATE COMPENSATION CACUATION In this TECHNICA GUIDANCE flow rate tables are indicated by flow rate of water (Density 1.0g/cm 3, Viscosity 1.0mPa s) and by flow rate of air (0 C, 1 atm). Thus, in case the actual operating condition differs from them, the following compensation calculation is required to obtain flow rate in such condition and then, tables are referred for selection. iquid measurement applicarions o ( f ) Cγ : Conversion coefficient C = ( f o ) γ o : Density of liquid to be measured (g/cm 3 ) γ : Density of water (g/cm 3 ) γ f : Density of (g/cm 3 ) (Refer to density table below) SUS30, SUS MA276 (Equivalent to Hastelloy C) 8.9 Calculation example Q W =Q A C =00 =00 o ( f ) ( f o) 1. (7.9 1) 1 (7.9 1.) = =1219/h Viscosity [mpa s] 5 1 Viscosity curve R-0 MA-B (Equivalent to Hastelloy B) 9.2 Titanium.5 Density of liquid 1.g/cm 3 SUS316 (7.9g/cm 3 ), full scale 00 /h Q A : Flow rate of actual iquid : Water converted flow rate Q W IMITATION OF FUID VISCOSITY Refer to the following figure in case of measurement of high viscosity liquid. If the viscosity of liquids is lower than the viscosity curve on the viscosity vs. flow rate graph below, flowmeters are manufactured as a standard procedure. The flow rate tables in this TECHNICA GUIDANCE can be referred to only by density compensation. If the viscosity is above the curve, contact Tokyo Keiso for detailed investigation by our factory computer ,000 5,000,000,000 (r/h) Gas measurement application No N P N P o Q N = Q No T o T N Q N : Air converted flow rate [m 3 /h (nor)] Q NO : Flow rate of actual gas [m 3 /h (nor)] γ NO : Density of gas to be measured [/m 3 (nor) ] γ N : Density of AIR to be measured [1.293/m 3 (nor) ] P o : Operating Press. [0.13+Op.press(Gauge)] [MPa abs] P N : Design Press. [0.13MPa abs] T O : Operating temp. [273+Op.temp( C)] [K] : Design temp. 273 [K] T N Calculation example CO2 gas 1.977/m 3 (nor), Op.press. 0.5MPa, Op.temp. C, Full scale 0m 3 /h (nor) Q = N = =5.m 3 /h (nor) PROCESS CONNECTIONS FOR EACH SIZE 0 0 JIS K Flange A A A A A A A A 0A JIS 5K Flange A A A A A A A A 0A * 1 * 1 *1 A and A are not available for meter mm (2). Rc 1/ 3/8 1/2 3/ 1 TG-F73-8E TOKYO KEISO CO., TD. 3

4 R-0 Series GASS TUBE FOWMETER SPECIA MATERIA, CONSTRUCTION PRODUCTS RIBBED TAPERED TUBE VERSION OUTINE is guided by rib construction inside of glass tapered tube. No rod is provided and they are suitable for measurement of liquids with certain solids. Also, the distance from inner surface to is stable and relatively close, and observation of is easier than that of standard flat tapered tubes. RIBBED TAPERED TUBE Ribbed tapered tube Stabilizer Available :,,,, (1), (2) and () Other specification is equal to that of STANDARD MATERIA PRODUCTS. ined material also available. CAPACITY RATING Flow rate* 1 Pressure Drop * 2 Water (/h) Air [m 3 /h (nor)] (kpa) (1) (2) to to *1: Flow rate for stainless steel s. *2: Approx. pressure drop at possible max. full scales. GASS INED PRODUCTS DIMENSION OUTINE For the measurement of very corrosive acids, e.g. Hydrochloric acid, Sulfuric acid, Chlorine gas, glass lined body flowmeters are used. imitation of manufacturing s is applicable. Refer to following. (mm) Available :,, and () Fluid temp : Max. 1 C Material : Body Glass lined cast iron Tapered tube Heat-resistant glass PVC, PTFE, MA (Equivalent to Hastelloy) Titanium, etc. PTFE, FPM, NBR, Others CAPACITY RATING Flow rate Water (/h) Air [m 3 /h (nor)] MA PTFE PVC PVC PTFE 9 to to to to 22 Other specification is equal to that of STANDARD MATERIA PRODUCTS TOKYO KEISO CO., TD. TG-F73-8E

5 R-0 Series GASS TUBE FOWMETER RUBBER INED, PVC INED PRODUCTS OUTINE This model consisting of all wetted parts made of rubber or PVC lined materials are suitable for corrosive services. Available : to 0 () Fluid temp. : Rubber lined Max.90 C PVC lined Max.60 C Other specification is equal to that of STANDARD MATERIA PRODUCTS DIMENSION : Model R-1 (mm) 0 (mm) CAPACITY RATING (1) (2) 0 Water (/h) PVC.PTFE 35 to Flow rate Air [m 3 /h (nor)] PVC PTFE 0.5 to to POYSUFON TAPERED TUBE VERSION (R-1-SU) OUTINE R-1-SU employs Polysulfone made tapered tube which is durable and suitable for strong alkalines such as caustic soda. This is very much suitable for caustic soda measurement application where glass tube is not suitable due to anti-corrosion capability against fluid. And also suitable for saturated brine lines. Measuring fluid Available :,, and () : Transparent liquids (Suitable for caustic soda and brine) Process connection : JISK flanges (Other flanged on request) Flow direction Fluid press. : Bottom to Top : Max. 0.5MPa Fluid temp. : Max. 0 C Indication Accuracy : ±3% F.S. Material availability No. Parts name Material Tapered tube Body Polysulfone PTFE, Titanium, steel, Others PP, Rubber lined, PTFE lined, steel EPDM, FPM 5 follower SS0 (SUS30) 6 Column SS0 (SUS30) DIMENSION Options : Normal flow rate indication pointer Optical alarm unit TG-F73-8E TOKYO KEISO CO., TD. 5 y r t y w q e CAPACITY RATING steel, 0.7 to Water flow rate (m 3 /h) Titanium 0.6 to Dimension (mm) PTFE Mass (Approx.) Connection 0.5 to 0.95,, mm 3.5,, mm 7,, mm,, 0mm

6 R-0 Series GASS TUBE FOWMETER R-5-RK and R-5-RKS PANE MOUNT, FOR GASES OUTINE R-5-RK and R-5-RKS are panel mount type glass tube flowmeter for gas measurement and very much suitable for monitoring of injection gas flow rate into furnaces. Ribbed tapered tube is used for stable indication even for low pressure gas supply line. Also, the pressure drop is designed low to meet the requirement in such applications. R-5-RK R-5-RKS Basic Model Code Series Connection Standard material material R-5-RKS - A A R - A N material - Alarm output Alarm output N: NBR F: FPM E: EPDM Z: Others - Pointer With or without pointer - Oil preventive treatment 0: Not treated 0: w/o special item 1: Treated Z: w/special item 0: Not provided 1: With 1 point 2: With 2 points O : With alarm : ower limit alarm - 1 point H : Upper limit alarm- 1 point H : Upper and lower limit alarm : ower limit alarm - 2 points HH : Upper limit alarm - 2 points Special item R-5-RK and - R-5-RKS material A: Aluminum : SUS30 6 : SUS316 Z : Others Standard material: Aluminum Standard R: Rc N: NPT Z: Others Rc connection is our standard. Corresponding with adapter (Male & Female) for other connection s Connection A: B: C: D: E: F: R-5-RK Aluminum 6 TOKYO KEISO CO., TD. A: 3/8 B: 1/2 C: 3/ D: 1 E: 1-1/2 F: 2 Same diameter as meter is standard. Corresponding with accessories like adapter (male and female) in case of different connection from meter Materials Body : SCS1 (R-5-RKS) Aluminum (R-5-RK) Tapered tube : Heat-resistant glass with ribs Measuring fluid : Gases such as air, nitrogen, propane Model code and butane R-5-RKS Available :,,,, and () SCS1 Heat-resistant glass Aluminum NBR SPCC SPCC SUS30 Installation : Panel mount Process connection : Rc Flow direction : Bottom rear to Top rear Fluid press : Max. 0.3MPa Fluid temp. range : 0 to 1 C Max. thermal shock : C Indication accuracy : ±2% F.S. (A pointer indicating normal flow rate can be installed on request) Alarm contact Contact Setting accuracy Reset span Enclosure Wiring Paint : Available on request, 1 or 2 points SPST, selfe-holding Reed switch ±2% F.S. Adjustable (Against flow calibration) Max.% F.S. (Against flow calibration) Water tight Direct connection to reed wire Metallic silver TG-F73-8E

7 R-0 Series GASS TUBE FOWMETER Capacity rating and approximate pressure drop for local indicator with aluminum DIMENSION Body Flow rate {Air, m 3 /h(nor} 1.1 to to to 1 12 to 2 2 to to 1 Pressure drop (kpa) Capacity rating and approximate pressure drop for alarm type with aluminum Flow rate {Air, m 3 /h (nor)}.8 to to to to to 1 Pressure drop (kpa) Full scale can be specified within the range of flow rates of each shown in above table with the rangeability :1. Figures in above table is the flow rate of air at 0 C and 1 atm with density /m 3 (nor). 2-d Panel cut OPTIONA PARTS PROTECTION COVER Transparent PVC and steel plate are ready to protect tapered tube. Specify if required. FOW ADJUSTING VAVE A valve for flow adjustment will be assembled onto flowmeter on request. ORDERING INFORMATION Notify the following for order/inqury Model R- - Fluid name Density Viscosity Press. Temp. Full scale A Connection mm inch Connection rating JISRF Rc (H) 1 Material Cast iron SUS30 SUS316 Other special ( ) Special instruction, if any (W) B - h 2- D Cautions on the use of glass tube variable area flowmeters MODE R-5-RK MODE R-5-RKS (H) (H) Dimension (mm) (W) B Dimension (mm) (W) B D D Panel cut (mm) h A Panel cut (mm) h A Mass (approx.) Mass (approx.) CAUTION Avoid the use of glass tube variable area flowmeters for the following services. 1. iquid services subject to impulse pressure in the process. 2. Secondary accidents might occur due to the breakage of glass in such services : Toxic fluids such as poisons, stimulant and narcotics Flammable fluids Explosive fluids 3. Gas handling process where breakage of glass might result in gas leakage or scattering of glass fragments.. The installation places of the flowmeters where breakage of glass might be caused by the accidents from the surrounding piping or equipment. 5. On-off operation where breakage of glass might be caused by the collision of the inside meter due to the abrupt change of flow. 6. Services where the heat shock by abrupt change of temperature is expected. TG-F73-8E TOKYO KEISO CO., TD. 7

8 R-0 Series GASS TUBE FOWMETER REATED PRODUCTS In addition to R-0 series Glass tube flowmeters, the following flowmeters are also available for cost effective and simple flow measurement : R-1-R AC series Glass tube flowmeters with alarm contact(s) The flowmeters made of PVC or engineering plastics are suitable for semiconductor manufacturing plants by eliminating introduction of metallic ions. NE series Glass tube flowmeter with standardized specification. Quick delivery and cost savaing! * Specification is subject to change without notice. Head Office : Shiba Toho Building, Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : 8 TG-F73-8E

FM MAG GAUGE METAL TUBE LEVEL GAUGE. MAG GAUGE Metal better than Glass!

FM MAG GAUGE METAL TUBE LEVEL GAUGE. MAG GAUGE Metal better than Glass! FM MAG GAUGE METAL TUBE LEVEL GAUGE MAG GAUGE Metal better than Glass! Safe construction; Metal tubes have no breakage and no leakage Clear vision; Free from blurs and contamination common to Gauge Glass

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Float Flow Meters series NF

Float Flow Meters series NF Float Flow Meters series NF - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small dimensions Doc. no.: 22, en_cat_nf, 8/2015 Usage Flowmeters type NF are

More information

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses Flowmeters QSE MAG FLOW METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation Systems Institutional Chilled

More information

VERIS Accelabar. Superior Flow Measurement Accuracy

VERIS Accelabar. Superior Flow Measurement Accuracy VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow

More information

Target Inline Flowmeter

Target Inline Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses Flowmeters QSE MAG FLOW METER Non-Intrusive (No moving parts) Electromagnetic Flow Meter Turf / Irrigation Agriculture Irrigation Turf Irrigation Systems Micro Irrigation Systems Institutional Chilled

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

TEMPERATURE SWITCHES AND THERMOSTATS

TEMPERATURE SWITCHES AND THERMOSTATS TEMPERATURE SWITCHES AND THERMOSTATS Our temperature switches and thermostats are ideal for applications where the end user is looking for highly accurate control across a wide range of operating temperatures.

More information

High Precision Gauge Pressure Indicators

High Precision Gauge Pressure Indicators Series 300 2¾" Dial High Precision Gauge Pressure Indicators For test, laboratory, and production uses, this gauge gives accuracy in a compact size. It is sensitive, yet rugged and low in cost. Available

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

Vortex EX DELTA lowmeter Technical Specifications

Vortex EX DELTA lowmeter Technical Specifications Product Data Sheet PDS-VX Vortex EX DELTA lowmeter Technical Specifications DESCRIPTION Rugged, yet simple, the Ex-DELTA vortex flowmeter is suitable for a variety of applications in liquid, gas, air and

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction

More information

AT9000 Advanced Transmitter Absolute Pressure Transmitters

AT9000 Advanced Transmitter Absolute Pressure Transmitters No. SS2-GTX00A-0500 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

D1 Series Multi-hole Cage Guided Control Valves

D1 Series Multi-hole Cage Guided Control Valves D1 Series Multi-hole Cage Guided Control Valves Model D1M Overview Model D1M globe control valves are with bolted bonnet and multi-hole cage guided trims. The design facilitates easy access to internal

More information

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD

More information

Dorot Irrigation Meter

Dorot Irrigation Meter DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features

More information

Smart Displacement type Level Transmitter

Smart Displacement type Level Transmitter No. SS-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters

More information

Motor-driven Diaphragm Metering Pump

Motor-driven Diaphragm Metering Pump Motor-driven Diaphragm Metering Pump OPEN Easy, Tough and Safe This stylishly designed safe TACMINA metering pump is easy-to-use and user-friendly developed with excellent utility, functionality and durability.

More information

SPECIFICATION SHEET. Measurement method. Measurement range switching. cell. 1 /2 inch dia ppm. cylinder cell. 1 /4 inch dia.

SPECIFICATION SHEET. Measurement method. Measurement range switching. cell. 1 /2 inch dia ppm. cylinder cell. 1 /4 inch dia. ISO-400 ISO-00 SPECIFICATION SHEET SS CONCENTRATION ANALYZER Model: SSD-0- Model: SSD-20- Model: SSD-30- DKK-TOA manufactures three versions of suspended solids concentration analyzers according to the

More information

F Series Flow Meter F300. User Manual

F Series Flow Meter F300. User Manual F Series Flow Meter F300 User Manual Contents 1. F300 Series Flow Meter ------------------------------------- 2 1.1 F300 Series Flow Meter Structure Drawing ---------------------------- 2 1.2 Introduction

More information

General Specification

General Specification General Specifications TB600G Laser Turbidity Meter GS 127A1 General With the recent development in membrane filtration technologies, organic filters have come into practical use as a highperformance treatment

More information

Alloy 20 29Ni-20.5Cr-3.5Cu-2.5Mo A351 CN7M J Mo 20Cr-18Ni-6.5Mo-N-Cu A351 CK3MCuN J93254

Alloy 20 29Ni-20.5Cr-3.5Cu-2.5Mo A351 CN7M J Mo 20Cr-18Ni-6.5Mo-N-Cu A351 CK3MCuN J93254 The typical Austentic Stainless Steel 18%Cr + 10% Ni have been adopted in corrosion resistant application for decades. In accordance with more and more application, the typical Austentic stainless steel

More information

Section 20. Globe Valves

Section 20. Globe Valves Section 20 A globe valve is a type of valve used for regulating flow in a pipeline, consisting of a movable disk-type element and a stationary ring seat in a generally spherical body. Globe valves are

More information

General Information, Industrial Thermocouple Section

General Information, Industrial Thermocouple Section INDUSTRIAL THERMOCOUPLES INDEX PAGE General Information... I1 Straight Base Metal Thermocouple Elements (IA)... I2 Angled Base Metal Thermocouple Elements (IB)... I3 Noble Metal Thermocouple Elements (IC,

More information

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series 70-82-03-14 June 08 Page 1 of 8 Specification Main Overview The specification of an Electrolytic Conductivity Cell requires

More information

SURFACE TEMPERATURE SENSORS

SURFACE TEMPERATURE SENSORS SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such

More information

Compact flue gas analyser: testo 300 M-I

Compact flue gas analyser: testo 300 M-I 220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial

More information

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS All rights reserved to thepetrostreet.com METER SELECTION PHILOSOPHY Reliability/ Repeatability Rangeability Versatility Economicsi Installation Cost

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 ) PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and

More information

FM MAG GAUGE METAL TUBE LEVEL GAUGE UP GRADED WITH WIDER LINEUP GENERAL OPERATION PRINCIPLE FEATURES

FM MAG GAUGE METAL TUBE LEVEL GAUGE UP GRADED WITH WIDER LINEUP GENERAL OPERATION PRINCIPLE FEATURES UP GRDD WIT WIDR INUP M MG GUG MT TUB V GUG GNR M Mag Gauge is a float type metal tube level gauge. iquid level is indicated by clear and visible color flappers. This eliminates problems likely in indication

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

289 Series Spring-Loaded Relief Valves

289 Series Spring-Loaded Relief Valves 89 Series Spring-Loaded Relief Valves Bulletin 71.4:89 April 1 W187_1 W1871 type 89L 1 NPT TYPEs 89H and 89HH W187 NPT TYPE 89H Figure 1. Types 89H, 89L, and 89U Relief Valves W187_ types 89U and 89A Introduction

More information

PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated check valve

PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated check valve Richter and -Way Sight Glasses PSG, TSG, SGS, SR Corrosion-resistant PFA and PTFE lining Indication of flow even at very low flow rates Optionally with integrated chec valve Richter and -way sight glasses

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

Vortex Mass Flowmeter

Vortex Mass Flowmeter Technology Solutions TE-VOR 1300C Vortex Mass Flowmeter FOW www.tek-trol.com Flow evel Temperature Pressure Valves Analyzers Accessories TekValSys Introduction A Tek-Vor 1300C Vortex Flowmeter (also called

More information

Visual Level Indicators VLI

Visual Level Indicators VLI WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The

More information

For Safe and Delicious Water

For Safe and Delicious Water RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and

More information

Figure 3. 1 Nutating Disc with R-10 register

Figure 3. 1 Nutating Disc with R-10 register Principle of Operation Liquid enters a precision-machined chamber containing a disc which nutates (wobbles). The position of the disc divides the chamber into compartments containing an exact volume. Liquid

More information

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Preso s complete line of Venturis offer reduced operating costs, proven accuracy, and great rangeability. Low permanent

More information

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice 00813-0100-4686 DS-4018 English Rev. FA ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice DP FLOW - THE INDUSTRY

More information

289 Series Spring-Loaded Relief Valves

289 Series Spring-Loaded Relief Valves 8/9 289 Series Spring-Loaded Relief Valves W187-2 W187-2 W21-1 W29-2 1-INCH TYPE 289H AND 289HH 2-INCH TYPE 289H Figure 1. Type 289H and 289HH Relief Valves The 289 Series relief valve is a throttling

More information

289 Series Spring-Loaded Relief Valves

289 Series Spring-Loaded Relief Valves February 1 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L, and 89U Relief Valves Introduction The

More information

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1.

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1. Industrial Electrolytic Conductivity Cells Main Overview The specification of an Electrolytic Conductivity Cell requires careful consideration of the following factors: 1. Appropriate Cell Constant, determined

More information

Catalogue EDITION: MAY 2014

Catalogue EDITION: MAY 2014 Catalogue EDITION: MAY 2014 Contact Details: PO Box 3200, Newstead Qld 4006 Ph: 07 3248 9600 Fax: 07 3041 3588 E-mail: rhgroup@therhgroup.com.au Contents Standard Pipemarkers 4 Custom Pipemarker Design

More information

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems Fox Thermal Instruments, Inc. Rich Cada 399 Reservation Rd. Vice President of Sales & Marketing Marina, CA 93933

More information

NUFLO Liquid Turbine Flow Meters

NUFLO Liquid Turbine Flow Meters TECHNICAL SPECIFICATIONS NUFLO Liquid Turbine Flow Meters Accurate Flow Measurement In 957, this flow meter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of

More information

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications Diaphragm Seals > Diaphragm Seals Diaphragm Seals Diaphragm seals, also referred to as chemical seals, are used to isolate pressure gauges, switches and transmitters from clogging and/or corrosive media.

More information

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86 High capacity, spring loaded swing type wafer check valve FEATURES Lightweight, wafer type check valve with face-to-face dimensions according ISO 5752, table 5 long High flow capacity featuring a special

More information

Industrial Flowmeters

Industrial Flowmeters spiraxsarco.com/global/us Industrial Flowmeters High-accuracy solutions for steam, gas and liquid flow applications 1 2 F l o w M e a s u r e m e n t S o l u t i o n s spiraxsarco.com/global/us Make Your

More information

07 SWIVEL JOINTS 268

07 SWIVEL JOINTS 268 07 7.01 The Range STRAIGHT SWIVEL JOINT Size : 1/2 to Working Pressure : 250 psi Page 270 90 SWIVEL JOINT Size : 1/2 to Working Pressure : 250 psi Page 271 FLANGED SWIVEL JOINT Size : 1/2 to Working Pressure

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design

More information

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION.  T.A. Morrison & Co. Inc. 1 SUBMITTAL DATA Series 9000 BF Thermally Insulated Damper with Thermally Broken Frames & Blades SP Standard Profile Flanged to Duct Install Type THERMAL BREAKS OPPOSED frame is 4 (101.6 mm) deep x 1 (25.4

More information

Magnet Float Type Level Gauge LT-1112/1212 series

Magnet Float Type Level Gauge LT-1112/1212 series Technical Information TI 034N/08/en Magnet Float Type Level Gauge LT-1112/1212 series Magnet float type level gauge using seal pipe Operation Principle LT 1112/1212 model float gauge features notable mechanism

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

Rosemount 405 Compact Orifice Primary Element

Rosemount 405 Compact Orifice Primary Element Rosemount 405 Compact Orifice Primary Element SPECIFICATIONS Performance Discharge Coefficient Uncertainty TABLE 20. 405 Compact Orifice Primary Element Type 405C (Conditioning Compact) 405P (1)(2) (Standard

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE Metaltite metal seated ball valves have excellent sealing characteristics suitable for various fluids services with a wide range of operating temperatures FEATURES GENERAL APPLICATION Clean fluids, dirty

More information

Flow Rate Transmitters/ Flow Switches

Flow Rate Transmitters/ Flow Switches Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate

More information

Richter Bellows-sealed Globe Control Valves

Richter Bellows-sealed Globe Control Valves Richter Bellows-sealed Globe Control Valves RSS NEW: Size DN 50/6 Corrosion-resistant PFA lining ISO/DIN and ANSI/ISA face-to-face Heavy-duty bellows Special designs for chlorine and high-purity media

More information

1301 Series High-Pressure Regulators

1301 Series High-Pressure Regulators 1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk

More information

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3) pplication and Type PN pplication for liquids, gases and vapours Ø D 80 BB EN BB SME PN Class 150 suitable for heating, air-conditioning, water supply and cooling installations,for applications where minimum

More information

94130 Pressure Relief Vent (Open or Closed Vent Option) Features

94130 Pressure Relief Vent (Open or Closed Vent Option) Features 94130 (Open or Closed Vent Option) The Shand & Jurs 94130 is designed to provide pressure relief with high efficiency, maximum flow capacity and minimum leakage. The easily serviceable configuration and

More information

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids SITRANS F X Vortex flowmeter The optimum measurement device for steam, gases and liquids SITRANS F Answers for industry. Totally integrated solutions from a single supplier Industry segments: Chemical

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

DIVA flowmeter. for saturated steam flow measurement

DIVA flowmeter. for saturated steam flow measurement DIVA flowmeter for saturated steam flow measurement DIVA the Direct In-line Variable Area flowmeter... Energy is often treated as an overhead but can represent a considerable part of the cost of production

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

Penberthy models RH and TH direct reading liquid level gages

Penberthy models RH and TH direct reading liquid level gages High pressure flat glass gages in reflex and transparent styles Features General application RH High pressure gages are designed to be used in direct reading liquid level measurement for high pressure

More information

Weir Valve Selections

Weir Valve Selections Unlined Metal Excellent Cvs Complete Selection of End Connections ASTM Materials Include: Cast Iron ASTM A-126 Class B Ductile Iron ASTM A-395 Grade 60-40-18 Cast Steel ASTM A-216 Grade WCB 316 Stainless

More information

One-part moisture-curing elastic adhesive meeting UL94V-0 flammability standard

One-part moisture-curing elastic adhesive meeting UL94V-0 flammability standard Technical Data ThreeBond 1537 Series [TB1537,TB1537B,TB1537D] Apr. 7, 29 Three Bond Co., Ltd. One-part moisture-curing elastic adhesive meeting UL94V- flammability standard 1. Outline ThreeBond 1537 Series

More information

brands you trust. Tufline Lined Ball Valves

brands you trust. Tufline Lined Ball Valves brands you trust. Tufline Lined Ball Valves Materials Of Construction Part 911 &944 911XP & 944XP Valves Only Ball PFA Lined Steel or Ductile Iron PFA Lined Steel or Ductile Iron Body & Tail PFA

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating

More information

Diaphragm seal with flange connection With internal diaphragm Model

Diaphragm seal with flange connection With internal diaphragm Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm Model 990.26 WIKA data sheet DS 99.26 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising

More information

Sulfuric acid dilution units

Sulfuric acid dilution units Sulfuric acid dilution units Sulfuric acid : H 2 SO 4 Applications and market Pigment producers (Titanium white, Barium white ) Fertilizer Plants / phosphate rock attack Iron & Steel / pickling baths Automotive

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features. VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet

More information

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved. PureFlex is a world leading manufacturer of high performance Fluoropolymer and Composite products and technologies. We specialize in the manufacturing of fluid handling and sealing products specifically

More information

The Liquiflo POLY-GUARD TM

The Liquiflo POLY-GUARD TM A Revolutionary Innovation in Chemical Pump Technology... The Liquiflo POLY-GUARD Polymer-Lined Stainless Steel Gear Pump...The Ultimate Solution for Pumping Corrosive Chemicals Combines the chemical resistance

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,

More information

Engineering Data Pack HD Industrial Duty Pumps

Engineering Data Pack HD Industrial Duty Pumps Engineering Data Pack HD Industrial Duty Pumps Version. Excellence at work. Excellence in life. Table of Contents 0A Pump Mounting Dimensions 0A Pump Mounting Dimensions with Flanged Ports Flanged Port

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership Data sheet DS/6/6EN Rev. K Models 600 & 600 Purgemaster SNP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength stainless steel body the body is corrosion

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

NRF CAPACITANCE LEVEL TRANSMITTER

NRF CAPACITANCE LEVEL TRANSMITTER NRF CAPACITANCE LEVEL TRANSMITTER Flow Pressure Level Temperature measurement monitoring control N2 Rigid and Suspended Designs Compact Microprocessor Based Designs High Accuracy NPT Threaded and Tri-Clamp

More information

VK 3. Control Equipment Control Equipment

VK 3. Control Equipment Control Equipment 2 3 Control Equipment Control Equipment SC7 SC7 5 SC7 M5.8 Effective Metered flow.5 sectional area mm 2 Free flow. Flow rate Metered flow 75 /min(anr) Free flow 7 Workin fluid Recommended tube SC7 M5.8

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet

More information

KLINGER Ballostar KHE: This ball valve offers more

KLINGER Ballostar KHE: This ball valve offers more KLINGER Ballostar KHE Split body ball valve DN (1/2 ) 0 ( ) Edition 10 Tel. + (0)2252 600-0 Fax + (0)2252 600- Web: www.klinger.kfc.at KLINGER Ballostar KHE: This ball valve offers more The design of

More information

Data Sheet 8008A Pressure Gauge

Data Sheet 8008A Pressure Gauge Data Sheet FEATURES Meets EN837-1 and ASME B40.100 specifications Corrosion resistant stainless steel case Dry gauges are field fillable Flutterguard standard on dry gauges Custom dials available Ventable

More information

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

COMBIMASS Thermal Gas Flow

COMBIMASS Thermal Gas Flow COMBIMASS Thermal Gas Flow The COMBIMASS series enables gas flow measurement for various applications in all industry sectors. COMBIMASS works according to the principle of thermal dispersion and determines

More information

Analytical Instruments

Analytical Instruments Smart Sensors Unique measurement technology Unique Innovations Honeywell is an industry proven leader for analytical products and solutions with unique technologies. Innovations in analytical measurements

More information

Gas Flow Monitor CMG Series User's Manual

Gas Flow Monitor CMG Series User's Manual No. CP-SP-1113E Gas Flow Monitor CMG Series User's Manual Thank you for purchasing the CMG Series Gas Flow Monitor. This manual contains information for ensuring correct use of the CMG. It also provides

More information

Thermocouple for Flue Gas Temperature Measurements,

Thermocouple for Flue Gas Temperature Measurements, Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and

More information