LOW VOLTAGE POWER CABLE
|
|
- Jeffery Franklin
- 5 years ago
- Views:
Transcription
1 HENGTONG OPTIC-ELECTRIC LOW VOLTAGE POWER CABLE CREATE A WORLD RENOWNED BRAND BUILD AN INTERNATIONAL EXCELLENT ENTERPRISE Global Information and Energy Network Service Provider HENGTONG OPTIC-ELECTRIC Add.: No. 0 Hengtong Rd., Wujiang Economic Development Zone, Suzhou, Jiangsu 1, China Tel.: Fax.: hengtong@htgd.com.cn Version CREATE EXCELLENCE ADVOCATE CIVILIZATION HTGDcorporation
2 Global Information and Energy Network Service Provider HENGTONG OPTIC-ELECTRIC
3 Power Transmission CONTENT 07 CU/XLPE/PVC CU/XLPE/PVC/AWA/PVC 11 CU/XLPE/PVC/SWA/PVC 13 AL/XLPE/PVC AL/XLPE/PVC/AWA/PVC 17 AL/XLPE/PVC/SWA/PVC 19 CU/PVC/PVC CU/PVC/PVC/AWA/PVC 3 CU/PVC/PVC/SWA/PVC AL/PVC/PVC 8 AL/PVC/PVC/AWA/PVC 9 AL/PVC/PVC/SWA/PVC 31 Recommended Multi Core Identification 3 Maximum D.C. resistances at 33 Rating Factors Current-carrying Capacities Optical Communication Copper Communication EPC Integrated solutions. A power, communications, and new energy provider. HENGTONG OPTIC-ELECTRIC Connecting A Smarter Future HENGTONG OPTIC-ELECTRIC, a member of the HENGTONG GROUP, is a global information and energy network service provider focusing on high-end technology and products. It is adapts to telecommunications and electricity trends and is dedicated to optical communication, power distribution and transmission, and a range of special transmission applications. HENGTONG OPTIC-ELECTRIC
4 Global Partners HENGTONG OVERVIEW Founded in 1991, IPO in 03, Stock code: SH The world's second largest cable manufacturer (CRU 14) China's top 0 enterprises (79th, ) Annual turnover USD 7. billion (15) subsidiary companies, 14,000 staff(15) Business Units Optical Communication Preform-optic fiber-optical fiber cables-odn (Capacity: 60 million fkm/year), Submarine optic cables. Power Transmission From Low-Voltage to High-Voltage, EHV (up to 0KV ), Submarine power cables,high-speed railway contact wires, OPGW. Copper Communications Areas Railway signal cables, Balise cables, Axle counting cables, Lan cables. Raw Material for Wires and Cables Provider of integrated power, communications, and new energy solutions 01 0
5 SPAIN PORTUGAL BRAZIL INDONESIA Industry Locations SOUTH AFRICA Sales&service Institutions 5 Brands 1 Operating In 1 Countries 9 Overseas Manufacturing Bases Sales & technical service institution United Arab Emirates fubo@htgd.com.cn Jordan huangff@htgd.com.cn Peru Thailand linxf@htgd.com.cn xingchihuang@gmail.com Iran songzy@htgd.com.cn Myanmar zhujw@hengtonggroup.com Egypt zhengc@htgd.com.cn Vietnam taofj@htgd.com.cn PORTUGAL Alcobre - Condutores Eléctricos, S.a. Telecommunication cables /LV power cables/ Digital signal cable for railway B D SOURTH AFRICA Aberdare Cable Proprietary Limited LV/MV/HV power cables / Overhead bare conductors SPAIN Cables De Comunicaciones Zaragoza,s.l Optical fiber / Data cables / Digital signal cable for railway Algeria Kenya Nigeria South Africa Mozambique Ethiopia lixygd@htgd.com.cn lintao@hengtonggroup.com lijun@htgd.com.cn jinpeng@htgd.com.cn anzy@hygd.com.cn lixiang@hengtonggroup.com Indonesia Cambodia Philippines Malaysia Sri_Lanka Taiwan jilei@hengtonggroup.com huangyj@htgd.com.cn shengxd@hengtonggroup.com liuc@htgd.com.cn shenliming@htgd.com.cn fengtao@hengtonggroup.com Congo liqian@htgd.com.cn Australia xuexun@htgd.com.cn Ghana jih@htgd.com.cn Pakistan szwang@hengtonggroup.com Sudan yanq@htgd.com.cn India hexy@hengtonggroup.com BRAZIL HT Cabos E Tecnologia Ltda Optical fiber cables CHINA Hengtong Optic-electric Co.,ltd. All series communication and power transmission products INDONESIA Pt Voksel Eletric Tbk. LV/HV Power cable/copper communication cables /Optic fiber/opgw Zambia Columbia Chile Brazil wuq@hengtonggroup.com wangt@hengtonggroup.com caoyunlong@htgd.com.cn huashun@htgd.com.cn Russia Turkey Poland Ecuador xuq@htgd.com.cn lijungd@hengtonggroup.com zhuangw@htgd.com.cn wuwj@htgd.com.cn 03 04
6 COMPANY INTRODUCTION Jiangsu Hengtong Power Cable Co., Ltd is one of the national key high and new technology enterprises owned by Hengtong Group. We successfully listed on Shanghai Stock Exchange in 03 with registered trademark: Hengtong Optic-electric (Stock Code: ). Our company is equipped with national advanced equipment like Finland NOKIA XLPE production line, German TRPESTER rubber extruding production line, Italy continuus-properzi aluminum and aluminum alloy CCR production line, America Southwire copper CCR production line and America HIPO partial discharge testing system and so on. We are the first company among the same industry field that introduce the various systems like OA, SAP, MES, CRM, SRM and other information management system, 6S, 6SIGMA, ISO9001, ISO11, OHSAS18001,CNAS and other management systems, using international advanced standards like IEC EN AS/NZS ASTM ICEA BS NBR NF SANS DNV and so on, implement whole faculty, whole process, whole performance as our quality control system. We mainly supply of MV & LV power cable, Control cable, Instrument cable, Aerial bundled cable, Optical fiber composite MV & LV power cable, Solar cable, Wind power cable, Electric Vehicle charging cable, Supper flexible anti-fire cable, Oilplatform cable, Shipboard cable, Mining cable, Copper bare conductor etc. series cable and solutions. Since the foundation of our company, we have established school-enterprise personnel and technical cooperation agreement with Xi an Jiaotong University, Shanghai Jiaotong University and Harbin University of Science and Technology and other universities nationwide and kept introducing all kinds of excellent talented people and advanced technology. Relying on the five innovation platforms and the advantage of owing 6 provincial research centers, Hengtong actively commits to the development and use of core intellectual property to achieve breakthroughs in core technologies. 05 Hengtong currently has 9 patents, including invention patents. In addition, the company develops more than five new products every year as a technical reserve or launched into the market. In recent three years, Hengtong has developed smart grids of OPLC, aluminum cables, rated voltage of 0.6/1kV and below ceramic silicone rubber fire-proof power cable, rated voltage of kv and below twist resistant soft cable for wind turbine, photovoltaic cable, reel cable, medium voltage twist resistant cable for wind turbine, environmental-friendly anti-termite power cable, LSOH(halogen free) cables for coal mines rubber sheathed soft cables, special wires and other products. In the new products developed these years, many of them have been rated to have a leading position in China and has an international advanced level. Some of the new products are initiative in China. With its excellent technology, quality and service, Hengtong s products are widely applied into more than industrial fields like the power, information, transportation, metallurgy, petroleum and petrochemical, coal, infrastructure, military industry, shipbuilding, marine engineering equipment and clean energy fields and a lot of large projects. Hengtong s products have been exported to 1 countries, gaining widely recognized and global reputation and keep advancing to the in-depth of the international market. 06
7 CU/XLPE/PVC CU/XLPE/PVC Copper conductor XLPE insulation PVC sheath Single core XLPE insulated cables with copper conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Min. temperature for laying and manipulation with cables: -5 Temperature range for operating: from - to +90 Colour of insulation: Natural Min. bending radius: OD Copper conductor XLPE insulation Filler PVC sheath Multi core XLPE insulated cables with copper conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Table 1 Min. bending radius: 15 OD smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC at ºC 1x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
8 3x4 3x6 3x 3x 3x 3x 3x 3x 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x.5 4x4 4x6 4x 4x 4x 4x 4x 4x 4x 4x1 4x1 4x 4x40 4x 4x 5x 5x.5 5x4 5x6 5x 5x 5x 5x 5x 5x 5x 5x1 5x1 5x 5x40 5x 5x at ºC smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, 1x 1x.5 1x4 1x6 1x 1x 1x 1x 1x 1x 1x 1x1 1x1 1x 1x40 1x 1x 1x0 CU/XLPE/PVC/AWA/PVC Single core XLPE Insulated cables with copper conductor and aluminium wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Natural Min. bending radius: 15 OD in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC 6. Hard-drawn aluminium wires PVC inner sheath XLPE insulation Copper conductor PVC outer sheath x
9 smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, x x.5 x4 x6 x x x x x x x x1 x1 x x40 x x 3x CU/XLPE/PVC/SWA/PVC Multi core XLPE Insulated cables with copper conductor and steel wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Table 1 Min. bending radius: 1D in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC PVC outer sheath Copper conductor XLPE insulation Filler PVC inner sheath Galvanized steel wires x4 3x6 3x 3x 3x 3x 3x 3x 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x.5 4x4 4x6 4x 4x 4x 4x 4x 4x 4x 4x1 4x1 4x 4x40 4x 4x 5x 5x.5 5x4 5x6 5x 5x 5x 5x 5x 5x 5x 5x1 5x1 5x 5x40 5x 5x at ºC x
10 AL/XLPE/PVC AL/XLPE/PVC Aluminium conductor XLPE insulation PVC sheath Single core XLPE insulated cables with aluminium conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Natural Min. bending radius: OD Aluminium conductor XLPE insulation Filler PVC sheath Multi core XLPE insulated cables with aluminium conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Table 1 Min. bending radius: 15 OD smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC at ºC 1x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
11 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x at ºC Hard-drawn aluminium wires PVC inner sheath XLPE insulation Aluminium conductor PVC outer sheath AL/XLPE/PVC/AWA/PVC Single core XLPE Insulated cables with aluminium conductor and aluminium wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Natural Min. bending radius: 15 OD 4x x x 4x 4x smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC x x1 4x x40 4x 4x at ºC 5x x x x x x x x x x x x x x x x x x x x x x x x x x x x
12 PVC outer sheath Aluminium conductor XLPE insulation AL/XLPE/PVC/SWA/PVC Multi core XLPE Insulated cables with aluminium conductor and steel wires armour 3x 3x1 at ºC Filler PVC inner sheath Galvanized steel wires Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 Operating conductor temperature: 90 Temperature range for operating: from - to +90 Colour of insulation: Table 1 Min. bending radius: 1D 3x1 3x 3x40 3x 3x 4x 4x x x smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC x 4x 4x x x1 4x at ºC 4x40 4x 4x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
13 CU/PVC/PVC CU/PVC/PVC Copper conductor PVC insulation PVC sheath Single core PVC insulated cables with copper conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: White Min. bending radius: OD Copper conductor PVC insulation Filler PVC sheath Multi core PVC insulated cables with copper conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: Table 1 Min. bending radius: 15 OD smoke & Halogen free, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC at ºC 1x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
14 3x6 3x 3x 3x 3x 3x 3x 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x.5 4x4 4x6 4x 4x 4x 4x 4x 4x 4x 4x1 4x1 4x 4x40 4x 4x 5x 5x.5 5x4 5x6 5x 5x 5x 5x 5x 5x 5x 5x1 5x1 5x 5x40 5x 5x at ºC smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, 1x 1x.5 1x4 1x6 1x 1x 1x 1x 1x 1x 1x 1x1 1x1 1x 1x40 1x 1x 1x0 CU/PVC/PVC/AWA/PVC Single core PVC Insulated cables with copper conductor and aluminium wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: White Min. bending radius: 15 OD in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC 6. Hard-drawn aluminium wires PVC inner sheath PVC insulation Copper conductor PVC outer sheath x
15 smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, x x.5 x4 x6 x x x x x x x x1 x1 x x40 x x 3x CU/PVC/PVC/SWA/PVC Multi core PVC Insulated cables with copper conductor and steel wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: Table 1 Min. bending radius: 1D in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC PVC outer sheath Copper conductor PVC insulation Filler PVC inner sheath Galvanized steel wires x4 3x6 3x 3x 3x 3x 3x 3x 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x.5 4x4 4x6 4x 4x 4x 4x 4x 4x 4x 4x1 4x1 4x 4x40 4x 4x 5x 5x.5 5x4 5x6 5x 5x 5x 5x 5x 5x 5x 5x1 5x1 5x 5x40 5x 5x at ºC x
16 AL/PVC/PVC AL/PVC/PVC Aluminium conductor PVC insulation PVC sheath Single core PVC insulated cables with aluminium conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: White Min. bending radius: OD Aluminium conductor PVC insulation Filler PVC sheath Multi core PVC insulated cables with aluminium conductor Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: Table 1 Min. bending radius: 15 OD smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, in concrete. The cables are resistant to UV radiation and to flame propagation according to IEC at ºC at ºC 1x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
17 3x 3x1 3x1 3x 3x40 3x 3x 4x 4x at ºC Hard-drawn aluminium wires PVC inner sheath PVC inner sheath Aluminium conductor PVC outer sheath AL/PVC/PVC/AWA/PVC Single core PVC Insulated cables with aluminium conductor and aluminium wires armour Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: White Min. bending radius: 15 OD 4x x x 4x 4x smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC x x1 4x x40 4x 4x at ºC 5x x x x x x x x x x x x x x x x x x x x x x x x x x x x
18 PVC outer sheath Aluminium conductor PVC insulation AL/PVC/PVC/SWA/PVC Multi core PVC Insulated cables with aluminium conductor and steel wires armour 3x 3x1 at ºC Filler PVC inner sheath Galvanized steel wires Standard: IEC 60.1 Rated voltage: 0.6/1(1.)kV Max. Short-circuit temperature: 0 (CSA mm), 140 (CSA>mm) Operating conductor temperature: Temperature range for operating: from - to + Colour of insulation: Table 1 Min. bending radius: 1D 3x1 3x 3x40 3x 3x 4x 4x x x smoke & Low halogen, Cold resistant, UV resistant, Oil resistant, in concrete with higher risk of mechanical damage. The cables are resistant to UV radiation and to flame propagation according to IEC x 4x 4x x x1 4x at ºC 4x40 4x 4x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
19 Recommended Multi Core Identification Maximum D.C. resistances at Category Recommended Multi Core Identification Nominal cross-sectional area Plain Class 1 Class Class 5 Class 6 Copper Copper Copper Copper Copper Aluminium Tinned Plain Tinned Plain Tinned Plain Tinned mm Ω/kM Ω/kM Ω/kM Ω/kM Ω/kM Ω/kM Ω/kM Ω/kM Ω/kM Phase A Brown Red Red Red Phase B Black Yellow Yellow White (or neutral) Phase C Grey Blue Green Blue Natural core Blue Black Blue Black Earth core Yellow/Green Yellow/Green Black Yellow/Green White for single PVC insulation core, Neutral for single XLPE insulation core. 31 3
20 Rating Factors VARIANCE: AIR AND CONCRETE SLAB AMBIENT TEMPERATURES CABLE TYPES: SINGLE-CORE OR MULTICORE INSTALLATION CONDITIONS: CABLES IN AIR OR HEATED CONCRETE SLABS VARIANCE: DEPTH OF LAYING Rating factor INSTALLATION CONDITIONS: IN UNDERGROUND WIRING ENCLOSURES Conductor temperature Air and concrete slab ambient temperature, Depth of laying m Single-core Rating factor Multicore VARIANCE: SOIL AMBIENT TEMPERATURE INSTALLATION CONDITIONS: CABLE BURIED DIRECT IN GROUND OR IN UNDERGROUND WIRING ENCLOSURES Rating factor 3.0 or more Conductor temperature Soil ambient temperature, VARIANCE: THERMAL RESISTIVITY OF THE SOIL (FROM 1. C.m/W) INSTALLATION CONDITIONS: BURIED DIRECT IN GROUND AND IN UNDERGROUND WIRING ENCLOSURES Thermal resistivity of soil C.m/W Multicore cable buried direct Two or three single-core cables buried direct Rating factor Multicore cable in a wiring enclosure Two single-core cables in a wiring enclosure* Three single-core cables in a wiring enclosure* CABLE TYPES: SINGLE-CORE OR MULTICORE VARIANCE: DEPTH OF LAYING INSTALLATION CONDITIONS: BURIED DIRECT IN GROUND Rating factor Depth of laying m Up to Conductor size, mm Above to Above * These rating factors apply to single-core cables enclosed separately, or grouped in a single wiring enclosure or more
21 Current-carrying Capacities CABLE TYPE: SINGLE-CORE CABLE TYPE: SINGLE-CORE INSULATION TYPE: PVC INSULATION TYPE: PVC MAXIMUM CONDUCTOR TEMPERATURE: C MAXIMUM CONDUCTOR TEMPERATURE: C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Current-carrying capacity, A Conductor size mm Unenclosed Space Space from surface Touching Exposed to sun Conductor size mm Enclosed Thermal insulation Buried direct Underground wiring enclosure Wiring enclosure in air Partially surrounded by thermal insulation Completely surrounded by thermal insulation CU CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL Stranded/Solid Flexible AL CU AL Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W
22 Current-carrying Capacities CABLE TYPE: SINGLE-CORE CABLE TYPE: SINGLE-CORE INSULATION TYPE: XLPE INSULATION TYPE: XLPE MAXIMUM CONDUCTOR TEMPERATURE: 90 C MAXIMUM CONDUCTOR TEMPERATURE: 90 C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Current-carrying capacity, A Conductor size mm Unenclosed Space Space from surface Touching Exposed to sun Conductor size mm Enclosed Thermal insulation Buried direct Underground wiring enclosure Wiring enclosure in air Partially surrounded by thermal insulation Completely surrounded by thermal insulation CU CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL Stranded/Solid Flexible AL CU AL Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to non-armoured, sheathed or unsheathed cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W 37
23 Current-carrying Capacities CABLE TYPE: TWO-CORE SHEATHED CABLE TYPE: SINGLE-CORE INSULATION TYPE: PVC INSULATION TYPE: XLPE MAXIMUM CONDUCTOR TEMPERATURE: C MAXIMUM CONDUCTOR TEMPERATURE: 90 C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Current-carrying capacity, A Conductor size mm Unenclosed Enclosed Space Touching Exposed to sun Exposed to sun Partially surrounded by thermal insulation, unenclosed Partially surrounded by thermal insulation, in a wiring enclosure Thermal insulation Buried direct Underground wiring enclosure Completely surrounded by thermal insulation, unenclosed Completely surrounded by thermal insulation, in a wiring enclosure Conductor size mm CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL CU AL CU AL Stranded/Solid Flexible AL Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W 39 40
24 Current-carrying Capacities CABLE TYPE: TWO-CORE SHEATHED CABLE TYPE: SINGLE-CORE INSULATION TYPE: PVC INSULATION TYPE: XLPE MAXIMUM CONDUCTOR TEMPERATURE: C MAXIMUM CONDUCTOR TEMPERATURE: 90 C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Current-carrying capacity, A Conductor size mm Unenclosed Enclosed Space Touching Exposed to sun Exposed to sun Partially surrounded by thermal insulation, unenclosed Partially surrounded by thermal insulation, in a wiring enclosure Thermal insulation Buried direct Underground wiring enclosure Completely surrounded by thermal insulation, unenclosed Completely surrounded by thermal insulation, in a wiring enclosure Conductor size mm CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL CU AL CU AL Stranded/Solid Flexible AL Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W 41 4
25 Current-carrying Capacities CABLE TYPE: THREE-CORE TO FIVE-CORE SHEATHED CABLE TYPE: THREE-CORE TO FIVE-CORE SHEATHED INSULATION TYPE: PVC INSULATION TYPE: PVC MAXIMUM CONDUCTOR TEMPERATURE: C MAXIMUM CONDUCTOR TEMPERATURE: C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Conductor size mm Unenclosed Enclosed Space Touching Exposed to sun Exposed to sun Partially surrounded by thermal insulation, unenclosed Partially surrounded by thermal insulation, in a wiring enclosure Thermal insulation Buried direct Underground wiring enclosure Completely surrounded by thermal insulation, unenclosed Completely surrounded by thermal insulation, in a wiring enclosure Conductor size mm CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL CU AL CU AL Stranded/Solid Flexible AL Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W 43 44
26 Current-carrying Capacities CABLE TYPE: THREE-CORE TO FIVE-CORE SHEATHED CABLE TYPE: THREE-CORE TO FIVE-CORE SHEATHED INSULATION TYPE: PVC INSULATION TYPE: XLPE MAXIMUM CONDUCTOR TEMPERATURE: C MAXIMUM CONDUCTOR TEMPERATURE: 90 C REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND REFERENCE AMBIENT TEMPERATURE: 40 C IN AIR, C IN GROUND Current-carrying capacity, A Conductor size mm Unenclosed Enclosed Space Touching Exposed to sun Exposed to sun Partially surrounded by thermal insulation, unenclosed Partially surrounded by thermal insulation, in a wiring enclosure Thermal insulation Buried direct Underground wiring enclosure Completely surrounded by thermal insulation, unenclosed Completely surrounded by thermal insulation, in a wiring enclosure Conductor size mm CU CU CU CU CU Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL Stranded/Solid Flexible AL CU AL CU AL CU AL CU AL CU AL Stranded/Solid Flexible AL Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W Notes: 1. Applies to cables with or without earth core, armoured or unarmoured, including neutral screened cables.. Air and concrete slab ambient temperature: Soil ambient temperature: 4. Depth of laying: 0.5m 5. Thermal resistivity of the soil: 1..m/W
0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath
0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular
More informationConstruction guideline
1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:
More informationDRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)
EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents
More informationPT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152
PT. KABELINDO MURNI Tbk WIRE AND CABLE MANUFACTURER No. QCS 00152 No. OSH 00971 No. EMS 00151 Introduction of company The Company s history was marked by the founding of PT. Kabel Indonesia (Kabelindo)
More information26/35kV Copper XLPE Insulation Electric Cable
26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32
More informationInstrumentation Cables
Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg
More informationEHV XLPE CABLES CDCC LINE
PROFILE THE HINDUSTHAN VIDYUT PRODUCTS LIMITED, established in the year 1959 is a leading manufacturer of Overhead Conductors and Underground Cables. The Company at its Faridabad Works has sophisticated
More informationMATERIAL STANDARD FOR CABLES AND WIRES
MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable
More informationSafeX110 Single Core Flexible Tinned Copper Cable
LSZH 110 C Flexible SafeX110 Single Core Flexible Tinned Copper Cable Application: Wiring of switchboards, control, general wiring, instrumentation and communication systems. Used where low smoke, zero
More informationType 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn
Mining Cable Type 1 Machine Cable Application: Typically used for interconnection of control boxes or motors on non-mobile or fixed apparatus. Used when exposure to heat is not an issue and where added
More information«CABLE T 92» WORKSHOP BALI, INDONESIA JUNE, 1992 POWER CABLES IN TROPICAL ENVIRONMENTS : SYNTHESIS. By L. DESCHAMPS SEE / EDF (France)
«CABLE T 92» WORKSHOP BALI, INDONESIA 22-23 JUNE, 1992 POWER CABLES IN TROPICAL ENVIRONMENTS : SYNTHESIS By L. DESCHAMPS SEE / EDF (France) SPONSORS ORGANISATIONS SEE / JICABLE PLN / ITB / APKABEL PATRONAGE
More informationXLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES
XLPE MATERIAL The trend of cross-linked polyethylene insulated cables into power cables field is quite prevalent in the world as the substitutes of paper insulated cables, which had played the leading
More informationSPECIFICATION FOR FRLS POWER CABLES
SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,
More informationTest Report No.: Page 2 of 35
Test Report No.: 50093959 001 age 2 of 35 Test Report AS/NZS 5000.1:2005 including amendment 1 Electric cables olymeric insulated for working voltages up to 0.6/1kV Test item particulars: 1C 4mm 2 to 16
More informationU.V resistance UL Sunlight Resistance. Flame retardant IEC
Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial
More informationCONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable
UNIT, BU1SNESS AREA OUR REFERENCE TR14-02-2E DATE 2018-01-24 CONSULTATIONS TECHNICAL GUIDELINE EDITION 1 APPROVED HVDC extruded cable This technical guideline describes the basic design and construction
More informationCaledonian Cables Ltd
Caledonian Motor Connection Cable Caledonian Cables Ltd s 1 Addison Addison Motor Connection Cable Company Profile Caledonian. established in 1978.offers one of the most complete lines of fiber and copper
More informationOFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable
OFFSHORE CABLES NEK 606 : 2016 with FIREBAR the TOTAL SAFETY fire and water resistant cable System certifications CCI Quality CCI Evironmental CCI Evironmental CCI Health & Safety CABLE SERVICE Quality
More informationQuality Through Experience. Company Profile
Quality Through Experience Company Profile Brief History of ÜNTEL Established in 1972 Partnership of Ünlü and Günan families since then 46 years of manufacturing experience with an extensive production
More informationH-FLEX CABLES 10/2017
10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL
More informationINSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES
Conducting Value INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES 400/7 ISO 900:08 Certificate No. CS-249 MANAGEMENT SYSTEMS Assessed to ISO 900:08 Cert/LPCB ref. 27 GOST ISO 900- (ISO 900:08) certification
More informationCopper Cable Company Limited
Cables and Wires Copper Cable Company Limited Copper Cable Company is the UK subsidiary of TELE-FONIKA Kable S.A., with offices and a warehouse centrally located in Leicestershire. 2 A major supplier to
More informationSUBMERSIBLE. Electric cables
SUBMERSIBLE Electric cables Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/06 Copyright Drawings and technical descriptions in this catalogue may not, under penalty
More informationMEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]
[6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-2 Second edition 2005-03 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 2: Cables
More informationYKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC
PVC insulated and PVC sheathed power cable CONSTRUCTION Conductors: annealed copper solid class 1(RE), circular or circular compacted stranded conductor class 2 (RM, RMC) or stranded sector shaped conductor
More informationDMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)
DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- T/0018/ DMRC-E-TR-CABLE-2 SPECIFICATIONS FOR 33 kv CABLES FOR ELEVATED AND Issued on: Date Stage
More informationNORMAS DE REFERENCIA AEIC CS 1: ASTM B
AEIC CS 1: Especificación para Solid-Type Impregnated-Paper-Insulated Metallic Sheathed AEIC CS2: Especificación para Impregnated-Paper and Laminated Paper- Polypropylene Insulated, High- Pressure Pipe-Type
More informationproject 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION
1.0 INTRODUCTION AND PROJECT INFORMATION Welspun Energy Ltd. is executing 18MW + 18MW + 14MW Solar PV Power Project for Mahagenco in Maharashtra (Site Location: Shirsuphal, Baramati Taluka, District Pune,
More informationL1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE
Engineering Specification Electrical Networks L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM OR COPPER CONDUCTOR 3.8/6.6kV XLPE INSULATED WITHOUT METALLIC SCREEN PVC Version:
More informationTechnical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables
Ergon Energy Corporation Limited Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables ETS03-01-04 Specification ETS03-01-04 Ver 2 Contents 1. Purpose and Scope... 1 2. References...
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
More informationNUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0
REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover
More informationTechnical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable
Ergon Energy Corporation Limited Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable ETS03-01-05 Specification ETS03-01-05 Ver 4 Contents 1. Purpose and Scope... 1 2. References...
More informationRT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015
RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015 The cables are designed primarily for trackside railway installation in non electrifi ed area. For direct burial application, brass tape
More informationInstrumentation and Thermocouple Cables
Conducting Value Instrumentation and Thermocouple Cables 400/4 Instrumentation and Thermocouple Cables CAVICEL 4 Construction and General Information 6 Construction 6 Noise 0 Thermocouple extension and
More informationInstrumentation and Thermocouple Cables
Conducting Value Instrumentation and Thermocouple Cables 400/3 Instrumentation and Thermocouple Cables CAVICEL 4 Construction and General Information 6 Construction 6 Noise 0 Thermocouple extension and
More informationTechnical Specification for Insulated Low Voltage Single Core Copper Cable
Ergon Energy Corporation Limited Technical Specification for Insulated Low Voltage Single Core Copper Cable ETS03-01-03 Specification ETS03-01-03 Ver 3 Contents 1. Purpose and Scope... 1 2. References...
More informationArmoured Instrumentation Cables to BS7917
Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable
More informationTele-Fonika Cable Americas
PUMP Cables Tele-Fonika Kable 2 TELE-FONIKA Kable S A, a privately held wire and cable manufacturer headquartered in Krakow, Poland, is one of the largest wire and cable companies in the world. TF operates
More information137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE
137-1: 2015 CEB SPECIFICATION XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE CEYLON ELECTRICITY BOARD SRILANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope
More informationThis document is a preview generated by EVS
IEC 60502-2 Edition 3.0 2014-02 REDLINE VERSION colour inside Power cables with extruded insulation and their accessories for rated voltages from 1 kv (Um = 1,2 kv) up to 30 kv (Um = 36 kv) Part 2: Cables
More informationOverview of Chinese Casting and Foundry Equipment Import and Export in 2007
May 009 Overview of Chinese Casting and Foundry Equipment and in 00 China Foundry Association Chinese casting production increased to 31,0,000 tons in 00, with an increase of.3% compared to 8,090,000 tons
More informationNPS/002/020 Technical Specification for 11 & 20kV Power Cables
Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements
More informationWIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES
WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES Table of content About Nexans 3 LV and MV voltage rubber cables 4 Cables sets for wind turbines 5 Medium Voltage Jumpers for Wind Application
More informationHighly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified
Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.
More informationCompany Profile. Company profile SHANDONG TAIKAI TRANSFORMER CO.,LTD.
Company Profile Company profile Shandong Taikai Transfomer Co., Ltd with registered capital of 200 million yuan, a wholly owned subsidiary of Taikai Group, is specialized in manufacturing various oil-immersed
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS PAGODA CABLES PVT. LTD. 1/58, STREET NO: 3, VISHWAS NAGAR, SHAHDARA, DELHI 110 032. (INDIA) TEL/FAX : 91-11-22392801, 22385391. Email : pagoda @del2.vsnl.net.in CONTENTS: 1. 2.
More informationElectric cables. CRANES APPENDIX
Electric cables. CRANES APPENDIX Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 06/0 Copyright Drawings and technical descriptions
More informationSECTION WIRES AND CABLES
SECTION 16120 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the supply and installation of wires and cables and the associated
More informationDEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE
DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE Antonio FARA, ENEL SpA, (Italy), antonio.fara@enel.it Ernesto ZACCONE, Prysmian SpA, (Italy), ernesto.zaccone@prysmian.com ABSTRACT High
More informationMESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN
Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED Version: 1 Issued: March 2014 Owner: Electrical Networks Asset
More informationDATA SHEET Single Core 2HR Fire Rated Cable
Features: 2HR Fire Rated 0.6/1kV Insulation Rating 110 o C Continuous Operation AS/NZS 3013 WS52W AS/NZS 5000.1 AS/ACIF S008 RCM Certified Low Smoke Zero Halogen Flame Retardant Flexible Class 6 Conductors
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationLIGHTNING PROTECTION INTERNATIONAL PTY LTD. EPR Safety Mat. Comprehensive Lightning, Surge Protection & Earthing Solutions.
Comprehensive Lightning, Surge Protection & Earthing Solutions Active in Industry throughout 70 countries The LPI story Lightning Protection International Pty Ltd (LPI) is a fully Australian owned manufacturer
More informationRail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE
Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... Railway Market: 100E Wire ZHPCG Cable SHF260 Flexible Cable Rail Wire Guide LFH Low Fire Hazard HALOGEN FREE
More informationHighly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified
Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.
More informationTECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1
ANNEXURE TO TENDER NO. PUR42396GM DATED 06 th FEBRUARY 2014 SUPPLY OF 1.1KV GRADE LT POWER CABLES FOR THE PERIOD APRIL 2014 MARCH 2016 TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 1.1 SCOPE
More informationConductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.
37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),
More informationFactors Affecting Current Ratings for Underground and Air Cables
Factors Affecting Current Ratings for Underground and Air Cables S. H. Alwan, J. Jasni, M. Z. A. Ab Kadir, N. Aziz Abstract The aim of this paper is to present a parametric study to determine the major
More informationHeat-resistant Cables Compensating Cables
Pho: HLUKABL Heat-resistant Cables Compensating Cables Heat-resistant Cables Compensating Cables High or low temperatures, heat and cold influences, permanent temperature changes demand cable types with
More informationTI 20 PVC TI 20 INSULATED TELEPHONE WIRE
TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2
More informationGlobal management and control system of automatic doors for BRT systems (Bus Rapid Transit)
Global management and control of automatic doors for BRT s (Bus Rapid Transit) What is it? How does it work? What does it consist of? It is an integrated of automatic doors for BRT stations that synchronises
More informationNPS/002/018 Technical Specification for Pilot, Control and Telephone Cables
Version: 4.1 Date of Issue: February 2016 Page: 1 of 25 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-31441-5 SOUTH AFRICAN NATIONAL STANDARD Electric cables with extruded solid dielectric insulation for fixed installations (300/500 V to 1 900/3 300 V) Part 3: PVC Distribution cables WARNING
More informationData sheet chainflex CFSPECIAL.182
Ethernet (CAT5/CAT5e/GigE/PoE) Profinet (Type C) 1 / 8 Cable structure Conductor Core insulation Stranded conductor in especially bending-resistant version consisting of bare copper wires (following DIN
More information138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )
138-1: 2015 CEB SPECIFICATION AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope 3 2.0 System
More informationSCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA
SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/LTPVC & CONTROL/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION
More informationSingle core conductor BETAtherm 145
Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with
More informationP.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT
CEB SPECIFICATION 005-1: 2012 P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS PAGE 1. Scope 03
More informationSeparator, suitable tape between the braid and outer sheath
Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC
More information7. EXTENSION LEADS AND COMPENSATING CABLE
7. EXTENSION LEADS AND COMPENSATING CABLE 7.1 INTRODUCTION : It is often desirable to connect a thermocouple probe, as a part of a very long circuit from the sensor itself to a remote reference unit and/or
More informationNPS/002/018 Technical Specification for Pilot, Control and Telephone Cables
Version: 4.0 Date of Issue: October 2015 Page: 1 of 21 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements
More informationNon-ferrous Minerals and Materials Produced by IAR Team Focus Technology Co., Ltd.
Non-ferrous Minerals and Materials 2013.06 Produced by IAR Team Focus Technology Co., Ltd. Contents 1. China Non-ferrous minerals and materials industry Export Enterprises Distribution... 4 1.1.2012 China
More informationSpecification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.
Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated
More informationComparison of BS 5308, PAS 5308 and BS EN
Comparison of BS 5308, PAS 5308 and BS EN 50288 Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308
More informationSECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR
SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR 458 7.3.1 11 KV Cables 7.3.1.1 General Where a Manufacturer s Standard or a national Standard equal to or better than the appropriate specified
More informationQuarterly Survey of Overseas Subsidiaries (Survey from July to September 2017) ~ Summary of the Results ~
Quarterly Survey of Overseas Subsidiaries (Survey from July to September 2017) ~ Summary of the Results ~ December 27, 2017 Research and Statistics Department Ministry of Economy, Trade and Industry 1
More informationFlexible Conduit Systems
Flexible Conduit Systems WHEN SAFETY MATTERS THERE S ONLY ONE CHOICE Complies to Australian & New Zealand Standards The Hi-Flex range of flexible conduit & fittings includes products tested to comply with
More informationP.V.C. INSULATED UNARMOURED COPPER CABLES
083 : 2007 CEB SPECIFICATION P.V.C. INSULATED UNARMOURED COPPER CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for P.V.C. INSULATED UNARMOURED COPPER CABLES CEB Specification 083 : 2007 CEYLON
More informationBSRIA Air Conditioning Worldwide Market Intelligence
2014 BSRIA Worldwide Market Intelligence Over 25 years experience researching key markets worldwide market intelligence in 94 Countries integrated technical and market expertise management consultancy
More informationOil and Petrochemical overview. solutions for your steam and condensate system
o i l a n d p e t r o c h e m i c a l o v e r v i e w Oil and Petrochemical overview solutions for your steam and condensate system Understanding your steam and condensate system At Spirax Sarco we understand
More informationTECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE
TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE SEAL & SIGNATURE OF THE TENDERER PAGE 1 OF 14 TECHNICAL SPECIFICATION FOR LT XLPE POWER CABLES (SPECIFICATION NO.MM/I/LTXLPE/2006) 1. SCOPE: The specification
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.
Translated English of Chinese Standard: TB/T1484.2-2010 www.chinesestandard.net Sales@ChineseStandard.net RAILWAY INDUSTRY STANDARD TB OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.280 S 35 Partially replacing
More informationComplies with NF C Standard
Complies with NF C 17-102 Standard LPI Product Offering Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd is a fully owned Australian manufacturer and supplier of direct
More informationNPS/001/007 Technical Specification for Overhead Line Conductors
Version:- 7.0 Date of Issue:- September 2016 Page 1 of 27 NPS/001/007 Technical Specification for Overhead Line s 1. Purpose The purpose of this document is to detail the range and technical performance
More informationContent HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables
Hybrid and Special Cables HYBRID AND SPECIAL CABLES Content Applications................................................................................ /3 page Construction examples of special cables
More informationENERGYFLEX, Guarantees long-term photovoltaic performance
, Guarantees long-term photovoltaic performance , unique features and exceptional quality: Solar panel Inverter Lifetime reliability: lasts up to 30 years even under tough external conditions Outdoor durability:
More informationPRY-MOULD. High Voltage Accessories for Extruded Cables
PRY-MOULD High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy
More informationIMPROVING SALES EFFECTIVENESS. John Kieffer Business Transformation Director
IMPROVING SALES EFFECTIVENESS John Kieffer Business Transformation Director Working from a Position of Leadership and Growth Global Sales: $26.6 Billion (65% International) Net Income: $4.0 Billion R&D
More informationENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting
More informationList Price w.e.f. 24th July, 2018
w.e.f. 24th July, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationINDUSTRY. Welding Cables. Highly flexible, resistant and robust.
INDUSTRY Welding Cables Highly flexible, resistant and robust. Flexible welding cables Weather resistant and robust These cables are designed for connection between welding apparatus and electrode as well
More informationCountry CAPEXIL Description HS Codes Value Qty AFGHANISTAN TIS Asbestos cement pipes
Country-wise and Item-wise Exports of Cement, Clinkers and Asbestos Cement Products Value Rs. Lakh Quantity in '000 Unit: Kgs Source: MoC Export Import Data Bank Country CAPEXIL Description HS Codes Value
More informationList Price w.e.f. 02nd January, 2018
w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationSQ. MM. 1 CORE 2 CORE 3 CORE 3.5 CORE 4 CORE
PRICE LIST 4 PVC/XLPE ARMOURED CABLES DATED : 1st NOVEMBER 2018 PVC / XLPE ARMOURED Cables with COPPER Conductor 1100 V. Grade confirming to IS : 7098 (Pt-1) 1988 PVC/XLPE ARMOURED Cables with ALUMINIUM
More informationFlexible Cables for Cranes and other industrial applications
Flexible Cables for Cranes and other industrial applications Fujikura Ltd. Version 3 Update Aug.13, 2014 1 Cable selection depending on the application Application 2/3PNCT-B G-/3PNCT-B 2/3PNCT-H 2/3PNCT-H-U
More informationTYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.
To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00
More information