RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) OF THR 8th PRIMARY SCHOOL TOILETS IN MYTILENE. Annex A - BILL OF QUANTITIES 1/9
|
|
- Charlene Bryant
- 6 years ago
- Views:
Transcription
1 RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) OF THR 8th PRIMARY SCHOOL TOILETS IN MYTILENE Annex A - BILL OF QUANTITIES 1/9
2 The Contractor shall consider in his price all costs or expenses of all requirements stipulated in the section entitled General preceding this Bill. General: 1. -All items listed in the data sheet scope of works, tehnical description, specifications, drawings and Bill of quantities. -The contractor's supplied materials, testing labor and overheads. -Protection of materials, Municipality property and public service equipment in the vicinity of the works. The contractor shall make the necessary temporary water, electrical power connections etc to prevent interruption of the power and water supply for the existing functioning building. The contractor is responsible to fix any damage that may occur during demolition and construction work. -Clearing and cleaning the places and transport the debris and litter collected to a place approved by the corresponding municipality, on his expenses,including any fees. -Scaffoldings and any kind and type of special equipment 2. Contractor's other costs for any item of work or obligation which is necessary for the completion of the works as required by the tender documents. All site and management costs, including salaries, general and insurance expenses, costs for temporary site facilities, site operation expenses, taxes, permits, all costs for labor, works, provisions, fuel, materials and equipment forssite Installations required by the Contractor and stipulated in the Tender Documents shall be included in the various unit prices of the Bill of Quantity. No extra payment will be allowed by the Employer for any of these activities. All skilled labour should have experience in renovation works,especially in old structures. The contractor shall take all necessary measures to protect and minimize environmental hazards including pollution, noise, dust etc. Abbreviation: m: meter lm: linear meter m2: square meter m3: cubic meter kgr: kilogram ls: lump sum pc: piece 2/9
3 Architectural & Civil Works 1 Demolishing & Dismantling Works -The contractor is responsible to fix any damage that may occur during demolition and construction work by replacing, repairing, and reinstatements of any infrastructure networks affected and/or damaged. -Clearing and cleaning the places and transport the debris and litter collected to a place approved by the corresponding municipality, on his expenses,including any fees. -Scaffoldings and any kind and type of special equipment are included in the rates. All skilled labour should have experience in renovation works, especially in old structures. The contractor shall take all necessary measures to protect and minimize environmental hazards including pollution, noise, dust etc. The contractor is obliged to use trucks with sealed cover. 1.1 Demolishing of existing floor tiles by hand tools, in any height, of all the places determined by the tender documents. Price should include removal of mortar. m Demolishing of existing wall tiles by hand tools, in any height, of all the places determined by the tender documents. Enlarge door opening, restore/repair and even out all surfaces. Strip out all aluminium doors. The price includes dismantling the door and any addition to it like upper parts and any other related items including all surrounding frames Strip out steel toilet door. The price includes dismantling the door and any addition to it like upper parts and any other related items including all surrounding frames Strip out existing steel frame with mesh (protective window frame) Demolishing and removing the existing contaminated plaster by hand tools, in any height, from all walls, beams, columns, roofs of all the places determined by the tender documents. Strip out existing toilet fixtures (except to the items in the adult toilet, boys' section) Uploading and removal of demolition products by manual or mechanical means to a designated municipal legal location, at any distance. m pc 1.00 pc 1.00 pc 1.00 m pc 8.00 m Concrete & Reinforcement Concrete Works 3/9
4 : The Contractor shall take into consideration that all direct and indirect works and expenses required for the completion of the coming items are included in the unit price. Rates of concrete works shall include: -Shuttering, supply and placing of concrete, vibrating, curing, striking. The concrete mix shall be transported in concrete transit mixing trucks in accordance with greek regulations and specification to avoid any contamination, segregation and loss of consituent materials. -Concrete additives -Making and transporting of formwork, oil, nails. -Mix ratio for reinforced concrete shall be in accordance with greek regulations and specification for concrete. Cleaning, fabrication, placing, the provision for all necessary temporary fixings and supports including tie wire and chair supports, laps, spacers and wastage Reinforced concrete C16/20, according to the National Concrete Technology Regulations (ΚΤΣ) Reinforcement steel mesh (B500c), supply, fabricate and installation of steel mesh T131,according to the National Standards m kgr Plaster Works 3.1 -Prices of plaster works for walls & ceilling roof shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by -All paints will be approved according to drawings, specifications, conditions and directed instructions by Repairing works and plastering of the walls - interior & exterior m Floor & Wall Tiling Works -Prices of tiling works for walls shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by -All tiles will be approved according to drawings, specifications, conditions and directed instructions by 4.1 Screed casting with mortar of 3-5 cm thickness. All works necessary for the supply and the installation are included to the cost. m /9
5 4.2 Floor Tiling - all interior floors. Ceramic floor tiles of dimensions 20 cm x 20 cm, skidproof and easy to clean. All works necessary for the supply and the installation are included to the cost. m Wall Tiling - all interior walls up to 1.80 m height (except the two walls where the childrens' wash basins are attached up to 2.00 m height). Ceramic wall tiles of dimensions 20 cm x 20 cm. All works necessary for the supply and the installation are included to the cost. m Marble sills to be placed underneath the entrance doors. Two pieces of 2 cm thickness. All works necessary for the supply and the installation are included to the cost. m Aluminum Works -Prices of aluminum works for the internal openings, drive handle for window (including lock) and handle and lock for door, shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by the Engineer or his representative. -All aluminum materials will be approved according to drawings, specifications, conditions and directed instructions by 5.1 Aluminum doors for the childrens' toilets, according to Greek Technical Standards ΕΤΕΠ All works necessary for the supply and the installation are included to the cost. 6 Steel Works -Prices of steel works, shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by the Engineer or his representative. -All steel materials will be approved according to drawings, specifications, conditions and directed instructions by 6.1 Window protective steel frame with galvanized mesh, 4Χ4 cm of dimensions 2.30 x 1.5 m (approximately) pc /9
6 7 Painting Works Preamble: -Prices of painting works for walls & ceilings shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by -All paints will be approved according to drawings, specifications, conditions and directed instructions by 7.1 Emulsion paint for the interior m Emulsion paint for the exterior m Metal door and window frame paint. Works include appropriate substrate preparation, coating with two-component adhesion primer on epoxy resin basis, and 2 full coats with alkyd resin hard-wearing enamel paint that is resistant to standard household cleaning agents. Water spout paint. Works include appropriate substrate preparation, coating with two-component adhesion primer on epoxy resin basis, and 2 full coats with alkyd resin hard-wearing enamel paint that is resistant to standard household cleaning agents. m m.m Finishing & Miscellaneous Interior Works Preamble: -Prices of finishes shall include supply of all materials, scaffolds, workmanship & tools and anywhere else, needed all according to drawings, specifications, conditions and directed instructions by the Engineer or his representative. -All paints will be approved according to drawings, specifications, conditions and directed instructions by Forged concrete. All works necessary for the supply and the construction are included to the cost. Door hooks (childrens' toilets). All works necessary for the supply and the installation are included to the cost. m EMVAC Works 6/9
7 -Rates of electrical installations shall include for: - Removing all unneeded electrical installations (if any) -Electrical works including all required materials, accessories, labor, all as required according to drawings, specifications and bill of quantities. - Cutting and pining including all making good -Forming, or cutting hales, chases, channels etc. in reinforced concrete structure, block works or existing walls. - Plugging and screwing -Preparation of all required workshop drawings and as built drawings. - Testing electrical installations including providing the services of professional personnel in the field of electricity that is necessary for testing, providing written reports & certificates by authorized electrical engineer approved by consultant. - The contractor shall make all the nessecary arragements in order to remove old connection and connect new lines - Protection of all electrical works - All outlets, switches, cables, wires should be labeled ( numbers & tags) - All conduits used should be fire retardant and color coded. 9 Electrical Works 9.1 Addition of switchgear in the existig panel pc Supply, installation and connection of distribution cables H05VV-R 3x1.5mm² Supply and installation of electrical conduit (pvc or hdpe) ind. Φ16 m m Supply and installation of junction boxes pc Supply and installation of lighting switches 9.6 Supply installation of lighting fixtures pc Mechanical Works 10.1 Supply and Install UPVC pipes PN6, as per ΕΝ 1329 ΕLΟΤ 686, laid, jointed, tested, with all required fittings and auxiliary materials, DN40, complete all as per drawings and m Supply and Install UPVC pipes PN6, as per ΕΝ 1329 ΕLΟΤ 686, laid, jointed, tested, with all required fittings and auxiliary materials, DN50, complete all as per drawings and m Supply and Install UPVC pipes PN6, as per ΕΝ 1329 ΕLΟΤ 686, laid, jointed, tested, with all required fittings and auxiliary materials, DN70, complete all as per drawings and m /9
8 10.4 Supply and Install floor drain, jointed and tested, with all required fittings and auxiliary materials, Ø50, complete all as per drawings and pc Dismantling and demolition of slab floors and walls, drilling of holes etc. for installation of pipes etc., complete all as per drawings and ls Filling and restoration of floors, walls, holes etc. after installation of pipes, complete all as per drawings and ls Supply and install white glazed fire clay squatting WC suite complete with flushing cistern and white glazed toilet paper holder, chromium plated water pillar valve 1/2" including 1/2" water supply pipe and flushing pipe running only externally and connected above floor with the pan, complete all as per Drawings and instructions of the Engineer. Elevation of the rain downpipe end and painting of the downpipe Supply and install white fire clay washing basin size 40x32 cm including waste trap fittings, plug and chain, steel brackets supports, chromium plated brass water faucet 1/2", with all required auxiliary materials, complete all as per Drawings and instructions of the Engineer. Supply and Install PP-R pipes PN15, as per DIΝ 8077/78, laid, jointed, tested, with all required fittings and auxiliary materials, DN15, complete all as per drawings and Supply and Install PP-R pipes PN20, as per DIΝ 8077/78, laid, jointed, tested, with all required fittings and auxiliary materials, DN20, complete all as per drawings and Supply and Install PP-R pipes PN20, as per DIΝ 8077/78, laid, jointed, tested, with all required fittings and auxiliary materials, DN25, complete all as per drawings and ls 1.00 m 4.00 m 8.00 m /9
9 Supply and Install ball valves of chromium plated brass, 1/2", complete all as per drawings and Supply and Install recessed chromium plated brass antifreeze water faucet 1/2", complete all as per drawings and Engineer instruction. 9/9
RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES
RFP/GRC/LSV/2017-003: RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES 1/7 The Contractor shall consider in his price all costs or expenses of all requirements stipulated
More informationDevelopment of the Urban Water and Sanitation Sector in South Sudan (DUWSS) Bill of Quantities. for LOCATED AT PRIMARY & SECONDARY SCHOOL.
Development of the Urban Water and Sanitation Sector in South Sudan (DUWSS) Bill of Quantities for SIX CHAMBER VIP LATRINE FACILITY LOCATED AT PRIMARY & SECONDARY SCHOOL YEI RIVER COUNTY South Sudan JUN,
More informationBILL OF QUANTITY ENGINEERING & MANAGEMENT CONSULTING CENTRE. "Beit Hanoun Emergency Water Supply Project"
"Beit Hanoun Emergency Water Supply Project" " Rehabilitation and Construction of Beit Hanoun Water Network " BILL OF QUANTITY ENGINEERING & MANAGEMENT CONSULTING CENTRE Bill of Quantities PREAMBLE TO
More informationKelly Village Apartments 3118 Green Houston, Texas 77020
Kelly Village Apartments 3118 Green Houston, Texas 77020 Houston Housing Authority J. Allen Management Managing Agent Scope for Kelly Village Unit #1125 Overall Scope: Demolition, Renovation, and Restoration
More informationSECTION BASIC ELECTRICAL MATERIALS AND METHODS
SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:
More informationTILE TILE
09300 - TILE 09300-1 PART ONE: GENERAL 1.1 Description TILE 1.1.1 Work of this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance with the requirements
More informationCONSTRUCTION AND REHABILITATION OF FENCE AT GPL'S VERSAILLES COMPOUND
BILL Nr1 - PRELIMINARIES 1.0 PRELIMINARY PARTICULARS 1.1 Funding The funding shall be provided by the Guyana Power & light Inc., of 40 Main street, North Cummingsburg, Georgetown. 1.2 Engineer The Engineer
More informationARCHITECTURAL DRAWINGS
PROJECT DETAILS Implementation Partner: Project title: Grant No.: KIS062 Content : ARCHITECTURAL DRAWINGS SHEET NO. REHABILITATION OF GRANT NO.: - KIS062 COVER SHEET INDEX SHEET CONTENTS 01 02 03 04 05
More informationQUANTITY SURVEYING DIVISION ASSESSMENT OF PROFESSIONAL COMPETENCE PART I ASSESSMENT SEPTEMBER 2013 WRITTEN TEST
PART I ASSESSMENT SEPTEMBER 2013 TIME ALLOWED: 3 hours 30 minutes Page 1 of 27 NOTES TO CANDIDATES A. Headings to questions are for ease of identification only and do not form part of the questions. B.
More informationWALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS SPECS FOR VASWANI PORTION. 200 mm solid concrete blocks. Reinforced Cement Concrete - Flat Roof
WALNUT CREEK - DETAILS OF TECHNICAL SPECIFICATIONS DESCRIPTION BASIC STRUCTURE Foundation Super Structure Internal Walls External Walls Roof RCC footing Framed Structure 200 & 100 mm Solid Concrete Blocks
More informationName of work: Renovation of toilets in main building near molecular biology lab. Sl Rate Amount Description Quantity Unit No Rs Ps Rs Ps Schedule A
SPECIFICATIONS AND SCHEDULE OF QUANTITIES Name of work: Renovation of toilets in main building near molecular biology lab Sl Rate Amount Schedule A 1 Demolishing concrete in cement mortar including disposal
More informationREQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES
REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES If your home or business incurred damage, the engineering department, in conjunction with the Flood Mitigation Officer, will
More informationHeavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:
TMI- is used widely in construction work for joints, stop-end, retaining walls and columns. It creates a strong bond base for successive pours. is fixed as permanent formwork. Key Product Features: Unique
More informationDIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.
DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units
More informationAppendix 4. Bills of Quantities
Appendix 4. Bills of Quantities 201 A4.1 Deep trench latrines Partitions of local materials 1m apart Timber foot rests and floor plates Lightweight timber frame Excavated soil (used for back-fill) Plastic
More informationSECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway
More informationBUILDING SKILLS. Building Skills : Basic Painting. Building Skills : Plaster & Tiler. Course Content : Course Content : Duration : 10 Days
Building Skills : Basic Painting Use and maintain hand tools Prepare new wall surfaces Prepare old wall surfaces Coat new wall surface with P. V. A Prepare wooden & metal surface (Door & Frame) for enamel
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationBILL OF QUANTITIES. Construction and Rehabilitation of wadi Gaza Bridges PAL Funded by Government of Brazil
United Nations Development Programme Programme of Assistance to the Palestinian People-PAPP Construction and Rehabilitation of wadi Gaza Bridges PAL10-00054031 Funded by Government of Brazil BILL OF QUANTITIES
More informationBill of Quantity (BOQ)
United Nation Development Programme Construction Salah El Deen Road Median From Al Zawaida entrance to Al Maghazi Northern entrance PAL 10-00071488 Bill of Quantity (BOQ) PREAMBLE TO BILL OF QUANTITY (BOQ)
More informationTEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up
TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,
More informationBILL NO 1 MASONRY SUPPLEMENTARY PREAMBLES BRICKWORK. Rectification Project Illinge, Eastern Cape Roof Replacement (Partially Done)
ectification Project oof eplacement (Partially Done) Item Quantity ate Amount BILL NO 1 MASONY SUPPLEMENTAY PEAMBLES BICKWOK Sizes in descriptions Where sizes in descriptions are given in brick units,
More informationSECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:
SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.
More information1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.
PAINTING GENERAL INFORMATION 1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats. DESIGN REQUIREMENTS 2.1 Material Compatibility: a. Provide materials
More informationSECTION OUTLET, PULL, AND JUNCTION BOXES
SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:
More informationUNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ. Original Issue Kabul University Project - Site Office Mobilization Kabul, Afghanistan
UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ Original Issue Kabul University Project Site Office Mobilization Kabul, Afghanistan Project Components: 1. Site Office Establishment NOTICE
More informationSECTION ALTERNATES
SECTION 01 23 00 - ALTERNATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationThe Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.
SECTION 05 31 13 STEEL FLOOR DECKING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including General and Supplementary Conditions and Division 01 - Specification
More informationSIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017
SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746
More informationA. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars
SECTION 04850 (04 40 00) MSI PRECAST STONE VENEER SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. MSI Precast Stone Veneer for exterior and interior vertical surfaces. 1.2 RELATED SECTIONS Specifier Notes:
More informationGeneral Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours
Basic Edition Standard Estimate Report Page 1 Name 1000 General Conditions 1107 Professional Consultant 10 Surveying 1.00 day 600.000 /day 600 - - - - - - 600 Professional Consultant 600 600 8.00 hours
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required
More informationTHE STRATA UNIT May 25, 2008
THE STRATA UNIT May 25, 2008 Over the years, we have been asked time and time again from our experience as a cost consultant and a project manager from both a restoration and renovation point of view What
More informationDIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE
DIVISION 13 - SPECIAL CONSTRUCTION SECTION 13080 - ACOUSTICAL PANEL ENCLOSURE 1 GENERAL 1.01 SUMMARY A. ACOUSTIC ENCLOSURE CONSISTING OF WALLS, CEILING, STRUCTURAL FRAMING, CONNECTING MEMBERS, DOORS, WINDOWS,
More informationSCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD AND
SCHEDULE OF FINISHES FOR THE AGREEMENT BETWEEN ZOTOS BROTHERS (PTY) LTD Zotos Place, 37 Old Kilcullen Road, Bryanston P O Box 68012, Bryanston, 2021 Tel: 011 463 2124 Fax: 011 463 2129 AND ERF: TOWNSHIP:
More informationDescription Unit Quantity Rate Kshs. Amount Kshs.
BILL No.1 40m3 MASONRY STORAGE TANK No. Description Unit Quantity Rate Kshs. Amount Kshs. 1 SETTING OUT AND EARTH WORKS 1.1 General site clearance and setting out 1.2 Excavate over site 200mm to remove
More informationTable of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities
Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)
More informationAnchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi
STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel
More informationA101 S001 1 SUB-BASEMENT 3/16" = 1'-0" SHEET (906) PH (906) FX 2 S101 NEW CONCRETE WALLS TO FORM WAVE TANK 3' - 0" 5' - 5"
5' - 5" 3' - 0" 2 S0 NEW CONCRETE WALLS TO FORM WAVE TANK 7 SHEET NOTES (906) 487-2303 PH (906) 487-329 FX 9/22/207 :34:03 AM FILE: \\nas2.dcs.it.mtu.edu\sas_homes\desktop\meem wave tank.rvt 7 2' - 4"
More informationSPACE TYPE: OUTSIDE PARKING (STRUCTURE)
SPACE TYPE: OUTSIDE PARKING (STRUCTURE) Construction Criteria The unit costs for Outside Parking (Structure) space types are based on the construction quality and design features in the following table.
More informationBOQ for Lintel, Chajja, Brick work & Plastering work at Pkg. - III - Phase - I
BOQ for Lintel, Chajja, Brick work & Plastering work at Pkg. - III - Phase - I S.No. Description Unit Qty RATE Amount PART-I CIVIL WORKS B-PLAIN AND REINFORCED CEMENT CONCRETE : Notes : ( the following
More informationCOLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100
COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,
More informationEstimate FOR THE SEPTIC TANK
Estimate FOR THE SEPTIC TANK S.NO ITEM DESCRIPTION. 1 Excavation in soil,soft & hard murum... Qty UNIT Rate Excavation for footing, machine foundation, plinth beams, wall footing, gutters,brick wall, tanks
More informationDivision 09 FINISHES TABLE OF CONTENTS
Division 09 FINISHES TABLE OF CONTENTS 09 1000 GENERAL... 3 A. RELATED SECTIONS... 3 B. MAINTENANCE OF FINISHES... 3 C. PUBLIC AREAS... 3 D. CUTTING AND PATCHING... 3 E. CLEANING... 3 F. RECOMMENDED FLOORING
More informationA. Submit the following in addition to the standard requirements.
SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,
More informationCLARIFICATIONS. Item 3. Specification Sections and A. All finish wood shall have sealer coat and two coats of finish material REVISIONS
Addendum #2 Project Name: Global Campus Interior Renovation Project Address: 2 E. Center Street Fayetteville, AR 72701 Date: 06/14/17 This document is issued as a response to Clarifications. These revisions
More informationFLUID APPLIED WATERPROOFING
SECTION 07120 FLUID APPLIED WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03300 - Cast-In-Place Concrete. 2. 09200 - Metal Studs, Metal Lath, Suspension Ceilings, Plaster, and Stucco.
More informationZukunftsbau GmbH, Strelitzer Str. 60, D Berlin The European qualification passport has been developed in cooperation with
QUALIFICATION PASSPORT 2 PREFACE Imprint Zukunftsbau GmbH, Strelitzer Str. 60, D 10115 Berlin euro@zukunftsbau.de The European qualification passport has been developed in cooperation with bfi (Austria),
More information11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...
Contents 11. Construction processes and materials... 11-2 11.1 Power House... 11-2 11.2 Maintenance Building... 11-2 11.3 Fuel Treatment Building... 11-3 11.4 Roads & Paths... 11-3 11.5 Fencing... 11-3
More informationSTRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225
GENERAL NOTES DESIGN NOTES (CONTINUED) FOUNDATION NOTES STRUCTURAL ABBREVIATIONS CONCRETE MASONRY NOTES DESIGN NOTES S-001 CONCRETE NOTES COLD-FORMED STEEL FRAMING NOTES PRE-ENGINEERED METAL BUILDING NOTES
More informationBILL SUMMARY. March 15, 2018 BILL No. DESCRIPTION AMOUNT
PROJECT: CONSTRUCTION OF NEW TIMBER WHARF, SOUTHERN BILL No. DESCRIPTION AMOUNT 1 PRELIMINARIES 2 DEMOLISHION WORKS 3 TIMBER WHARF CONSTRUCTION 4 CATWALK CONSTRUCTION BILL SUMMARY 5 CONCRETE WALKWAY CONSTRUCTION
More informationINDICATIVE FEASIBILITY BUDGET (RIBA STAGE 1) for ST JAMES'S CHURCH : WEYBRIDGE SURREY. June 2016
INDICATIVE FEASIBILITY BUDGET (RIBA STAGE 1) for INTERNAL REPAIRS AND REDECORATIONS OF THE CHURCH HALL at ST JAMES'S CHURCH : WEYBRIDGE SURREY June 2016 SAWYER & FISHER (EPSOM) LTD THOMAS FORD & PARTNERS
More informationSPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work
SPECIFICATION FOR THE DEVELOPMENT OF LPA CLEAN ROOM INFRASTRUCTURE Description of work Creation of Three clean area rooms (Master Mix, Amplification and Hybridization rooms) for Line Probe Assay with two
More informationBILL NO 1 ALTERATIONS SUPPLEMENTARY PREAMBLES
ectification Project oof replacement Item Quantity ate Amount BILL NO 1 ALTEATIONS SUPPLEMENTAY PEAMBLES View site Before submitting the tender the contractor shall visit the site and satisfy himself as
More informationMarch 6, Subject: Addendum No. 2 Invitation for Bid No Toyota Park Transit Center Phase II. Ladies and Gentlemen:
March 6, 2018 Subject: Addendum No. 2 Toyota Park Transit Center Phase II Ladies and Gentlemen: This Addendum No. 2 is being issued to provide responses to questions submitted by potential bidders and
More informationDIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK
DIVISION 03 CONCRETE SPECIFICATION 031000: FORMS AND FORMWORK PART 1.0 GENERAL 1.1 DESCRIPTION The work of this specification includes furnishing of all labor, materials, equipment and incidentals to install,
More informationCentral Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS
Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society
More informationBuildingName The Description of the Project P DOCUMENTS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationSECTION 07530CP EPDM MEMBRANE ROOFING
PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL
More informationArchitectural Details. Walls. Including PVC cove, UL Listed Raceway, & Integration to Flooring. AES Pharma Wall & Walk-On Ceiling Cleanroom System
Architectural Details Section One Walls Including PVC cove, UL Listed Raceway, & Integration to Flooring AES Pharma Wall & Walk-On Ceiling Cleanroom System Architectural Components AES PHARMA SYSTEM AES
More informationCONTRACT DOCUMENTS REVIEW PACKAGE CHECKLIST
CONTRACT DOCUMENTS REVIEW PACKAGE CHECKLIST Check off each item that is included within the submitted Contract Documents Review Package. Provide a written explanation for any omissions. The following items,
More informationBOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) SANITARY FIXTURES a Providing & Fixing star white colour vitreous china wall mounted wc with heavy duty
More informationSchedule T5. Tender Documents. This tender is for: Tender Documents: The documents issued for this tender include the following: Tender Schedules
Schedule T Tender Documents T This tender is for: Contract: Location: Tender Documents: Norrie Home 56 Hardinge Road The documents issued for this tender include the following: Tender Schedules Schedule
More informationPremier Inn, Wilson Street, Middlesbrough, TS1 1AE. Site progress report. February 2017
Premier Inn, Wilson Street, Middlesbrough, TS1 1AE Site progress report February 2017 Site set up Currently 4 weeks in to the build the site has been cleared and hoardings have been erected. Welfare cabins
More informationSECTION PRECAST CONCRETE BUILDING PREFABRICATED. ACI , "Building Code Requirements for Reinforced Concrete".
SECTION 13120 PRECAST CONCRETE BUILDING PREFABRICATED PART I - GENERAL 1.01 SUMMARY Contractor to furnish precast concrete building. Building to be field erected on customer prepared crushed stone foundation
More informationPlanning and installation instructions
Planning and installation instructions Stofix Oy Ahlmaninkatu 2 E 40100 Jyväskylä Finland stofixgroup@stofix.com www.stofix.com 2 PLANNING AND INSTALLATION INSTRUCTIONS... 1 1 General... 3 2 Project Design...
More informationANNEXURE B SECTION 1
ANNEXURE B SECTION 1 HOUSING SPECIFICATIONS 1. Houses 1.1. Roofs Material: Architect approved concrete tiles @ 17,5 degree pitch on SABS approved underlay Colour: As per Architects. 1.2. Rainwater goods
More informationAluminum-Framed Entrances and Storefronts
University of New Hampshire University of New Hampshire Scholars' Repository Division 08 Openings Chapter 5 Technical Construction and Renovation Standards 1-25-2013 084113 - Aluminum-Framed Entrances
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More informationSECTION STEEL DECKING
SECTION 05 31 00 STEEL DECKING SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Refer to Section 05 36 00, COMPOSITE METAL DECKING for floor
More informationUNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ. Original Issue Bamyan MAC Site Services - Phase 1 Bamyan, Bamyan, Afghanistan
UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ Original Issue Bamyan MAC Site Services Phase Bamyan, Bamyan, Afghanistan Project Components:. Site Services Phase NOTICE TO ALL BIDDERS COMPLETE
More informationNo # Specifications Rate To Be Quoted. Unit Qty (in figures) (in words) Total Amount
Revised Schedule B as per corrigendum no. SASB/NIT/Works/818/2016/09 dated 28.01.2016. SCHEDULE B (FINANCIAL BID) B- a FABRICATION AND SUPPLY OF 200 EUROPEAN TYPE TOILETS (Rate to be quoted in Rupees both
More informationMATERIAL ALLOWANCES AND UNIT PRICES
PART 1 - GENERAL 1.1 SECTION INCLUDES ADDITIONS AND RENOVATIONS TO WEST YORK AREA HIGH SCHOOL - #1231 SECTION 012200 MATERIAL ALLOWANCES AND UNIT PRICES A. Measurement and payment criteria applicable to
More informationDIVISION 05 METALS Commissioning of Metals STRUCTURAL METAL FRAMING Structural Steel Framing
DIVISION 05 METALS 05 00 00 METALS 05 01 00 Maintenance of Metals 05 01 10 Maintenance of Structural Metal Framing 05 10 20 Maintenance of Metal Joists 05 10 30 Maintenance of Metal Decking 05 10 40 Maintenance
More informationSPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)
SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) Construction Criteria The unit costs for the Physical Fitness Center (Exercise Room) space type are based on the construction quality and design features in
More informationW i s d o m S m a r t C o l l e c t i o n. Aristotle series
W i s d o m S m a r t C o l l e c t i o n Aristotle series 8490mm Aristotle 16 Area Calculations ARIstotle 16 Itemised Floor Areas Ground Floor Garage Porch Outdoor Leisure Area 118.22 sqm 20.04 sqm 1.53
More informationSECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING
7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes
More informationSPECIFICATION FOR PIPE CULVERT CONSTRUCTION
SPECIFICATION FOR PIPE CULVERT CONSTRUCTION 1. SCOPE Pipe culverts shall be constructed in accordance with this specification and in conformity with the lines, levels and cross-sections shown on the drawings.
More informationPROFESSIONAL DESIGN MANUAL INDEX
PROFESSIONAL DESIGN MANUAL INDEX DIVISION A--GENERAL PROJECT REQUIREMENTS... A2-A15 A.1 INTRODUCTION... A-2 A.2 CODES COMPLIANCE (VERIFY CITY REQUIREMENTS)... A-5 A.3 SPECIAL SUBSURFACE AND LAND CONDITIONS...
More informationDIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations
DIVISION 11 - EQUIPMENT 11400 FOOD SERVICE EQUIPMENT A. Design Considerations 1. The A/E shall use the services of a food service equipment specialist in preparation of kitchen areas and other food preparation
More informationA. BILL OF QUANTITIES FOR SANITARY SEWER
Note: Unit prices of BoQ items shall include the execution of all small and unforeseen works not covered by BoQ, but that are necessary to be carried out during construction for smooth process of works
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More informationSAMPLE. Slab On Ground Construction. Carpentry - Residential Construction. Product Code: 5597
Slab On Ground Construction Carpentry - Residential Construction Product Code: 5597 Publishing details: Second Edition 2012 TAFE NSW Training and Education Support, Industry Skills Unit Orange and Granville
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More information1 BASE HOME CONSTRUCTION SPECIFICATIONS: TOWNHOMES 5-13-2015 Note: Specifications noted below may change based on selected options. Verify upgrades from the base specifications with the option sheets and
More informationSECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM
ARCHITECTURAL SPECIFICATIONS MANUFACTURER: InterBlock LLC PO Box 1123, Sheboygan, WI 53082 Phone Number 920-207-7234 SECTION 03100 STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM PART 1 GENERAL 1.01 Summary
More informationALL-ALUMINUM DOOR & WINDOW FRAMING
ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum
More information10 EXTREME BASEMENT PANELS
10 EXTREME BASEMENT PANELS On Granular Footings 1. The type of soil is a factor in determining foundation construction details such as footing design, backfill, and drainage provisions. Soils are classified
More informationRUWAIS HOUSING COMPLEX PHASE IV CIVIL & ELECTROMECHANICAL WORKS
AL NASR SCOPE OF WORKS: Construction of water storage tank consisting of: 3 Water storage tanks 2,641,721 gal of 42 m diameter and 7.65 m each 2300 m³ of concrete 2450 m² of water proofing external 4300
More informationPART A: JOB PROCDRE FOR PLASTERING
PART A: JOB PROCDRE FOR PLASTERING 1. SCOPE: The scope of this procedure shall apply to all cement plaster finishes to column, ceilings, walls and similar surfaces on backgrounds met with such as brick,
More informationHIGHLANDVIEW CEMETERY CHAPEL
HIGHLANDVIEW CEMETERY CHAPEL CONTACT: Ferris State University Small Town Studio Christopher Cosper, AIA, LEED, AP, Assistant Professor cosperc@ferris.edu 23.59.33 Sheet List Sheet Name Sheet # COVER A00
More informationSTATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804
STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION PROJECT #: CAP 1804 FRANCONIA NOTCH STATE PARK FRANCONIA, NEW HAMPSHIRE BID SET 8/4/2017 DRAWING LIST:
More informationElectric Service Standards
V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are
More informationBuilding Systems and Design Elements included in SliDeRulE
Building Systems and Design Elements included in SliDeRulE No. System Subsystem Design Element 1.1.1 Foundation Deep Foundation Steel H-pile 1.1.2 Foundation Deep Foundation Steel pipe pile 1.1.3 Foundation
More informationSECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes pipe and equipment supports, hangers, anchors, bases sleeves and the sealing of work
More informationSCHEDULE OF QUANTITIES INTERIOR WORKS FOR RACC,GADAG Description Qty. Unit Rate Amount
Item No. 1 PARTITION 1.1 DOUBLE SKIN WOODEN PARTITION SCHEDULE OF QUANTITIES INTERIOR WORKS FOR RACC,GADAG Description Qty. Unit Rate Amount Providing and fixing 71 mm thick solid fully or partly glazed
More informationB. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.
SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping
More informationRODINNÉ DOMY STODŮLKY. Standards
RODINNÉ DOMY STODŮLKY Standards BUILDING Floors in residential rooms Entrance hall Kahrs Linnea 3-layer veneer floor, 3-parquet, finished with a moulding, a selection from natural oak and bleached oak
More informationSECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION
820-1 SCOPE OF WORK: SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION a. Furnish all labor, materials, equipment, and incidentals required for demolition and/or removal and disposal of existing
More informationRCC PRECAST TOILET UNITS
RCC PRECAST TOILET UNITS TOILET UNIT PHOTO TOILET UNIT PLANS PDG Vinay Kulkarni Wins Coordinator West Zone Quotation for Toilet Units with Bio Digester Sr. Description Price (Rs.) Unit No. 1 TTSS1: 1 Super
More information