Test Report P 1.1/ (01) dated , 1 st copy
|
|
- Julius Berry
- 6 years ago
- Views:
Transcription
1 Officially recognized test body for construction materials, structural elements and design PÜZ body according to federal construction work regulation (SAC 02), legislation on construction products (NB 0800) Section I materials in the construction industry Division manager: Dr.-Ing. Frank Dehn AG Concrete and Masonry Test Report P 1.1/ (01) dated , 1 st copy Subject Matter: Customer: Test on water penetration depth on concreted spacers, according to DBV instruction sheet spacers, Type AD 4013 Max Frank GmbH & Co. KG Mitterweg 1 D Leiblfing Date of order: Receipt of Test Specimens: Taking of Samples: Marking: Customer Please refer to report Test period: March 10 to March 16, 2006 Person in charge: Dipl.-Ing. (FH) Kuban The present test report consists of 2 pages and 2 annexes. The present report may only be published completely. Its publication even if it refers to excerpts of the report only - is solely allowed after prior written consent given by. Association for research on materials and test body for the construction industry Leipzig mbh Managing directors: Univ-Prof. Dr.-Ing. Stefan Winter, Dr.-Ing. Frank Dehn Main Office: Hans Weigel Straße 2b, D- Phone: +49 (0) 341/ Fax: +49 (0) 341/ kuban@mfpa-leipzig.de Commercial Register: Local first-instance court Leipzig HRB Turnover ID number: DE Bank account: Sparkasse Leipzig Account number BLZ /1 - E 10/08
2 Test Report Page 2 Department for materials in the construction industry P1.1/ (01) of 2 Pages 1. Preliminary notes On March 2, 2006, we received a consignment comprising a total of 6 concrete test cubes (dimensions 20 x 20 x 20 cm each), with concreted concrete spacers, for tests on water penetration depth, according to the DBV instruction sheet spacers, issued in July 2002, as well as 6 concrete test cubes (dimensions 15 x 15 x 15 cm each) made of reference concrete. 2. Test execution 2.1 Test series concrete test cubes with concreted spacers Chart 1 Nr. Date of production Concrete quality Designation Spacer designation Test start Age of specimens Max. penetration depth Max. penetration depth spacers C 25/30 Cube 1. A-A AD C 25/30 Cube 2. A-A AD C 25/30 Cube 3. A-A AD C 35/45 Cube 1. B-A AD C 35/45 Cube 2. B-A AD C 35/45 Cube 3. B-A AD Test series concrete test cubes reference concrete Chart 2 Nr. Date of production Concrete quality Designation Test start Age of specimens Max. penetration depth C 25/30 Cube1.A-A C 25/30 Cube 2.A-A C 25/30 Cube 3.A-A C 35/45 Cube 1.B-A C 35/45 Cube 2.B-A C 35/45 Cube 3.B-A Test result With regard to the water penetration depth, the DBV instruction sheet spacers, paragraph 2.2.4, specifies a limit value of max. 50 mm. Leipzig, this 12 th day of April 2006 Dipl.Ing. M. Becker Head of working group Concrete and masonry Dipl.Ing. (FH) Th. Kuban Person in charge Annexes: Annex 1 photo documentation Annex 2 test reports on impermeability to water
3 Annex 1 to test report Department for materials in the construction industry 1.1/ (01) Page 1 of 1 Photo documentation (Photos 1 to 6) Photo 1: Test specimen 1 AA, AD4013, C25/30 Photo 2: Test specimen 2 AA, AD 4013, C 25/30 Photo 3: Test specimen 3 AA, AD 4013, C 25/30 Photo 4: Test specimen 1 BA, AD 4013, C 35/45 Photo 5: Test specimen 2 BA, AD 4013, C 35/45 Photo 6: Test specimen 3 BA, AD 4013, C 35/45
4 A 2.1. Annex 2 to test report P 1.1/ (01) Page 1 of 4 pages Concrete type number: AD 4013 Consistency class: C 25/ Test specimen characteristics: 1 AA 2 AA 3 AA Date of test start: Dimensions in mm: 200x200x x200x x200x200 Max. penetration depth mm: 10 (5) 20 (3) 16 (4) Average value: mm Comments: () Spacers Leipzig, this 16 th March 2006
5 A 2.1. Annex 2 to test report P 1.1/ (01) Page 2 of 4 pages Concrete type number: AD 4013 Consistency class: C35/ Test specimen characteristics: 1 BA 2 BA 3 BA Date of test start: Dimensions in mm: 200x200x x200x x200x200 Max. penetration depth mm: 23 (5) 20 (6) 13 (6) Average value: mm Comments: () Spacers Leipzig, this 16 th March 2006
6 A 2.1. Annex 2 to test report P 1.1/ (01) Page 3 of 4 pages Concrete type number: Consistency class: C 25/ Test specimen characteristics: AA1 AA2 AA3 Date of test start: Dimensions in mm: 150x150x x150x x150x150 Max. penetration depth mm: Average value: mm 16 Comments: Leipzig, this 10 th March 2006
7 A 2.1. Annex 2 to test report P 1.1/ (01) Page 4 of 4 pages Concrete type number: Consistency class: C 35/ Test specimen characteristics: BA1 BA2 BA3 Date of test start: Dimensions in mm: 150x150x x150x x150x150 Max. penetration depth mm: Average value: mm 13 Comments: Leipzig, this 13 th March 2006
W TT FPA Leipzig GmbH Testing, Inspection and Certification Authorityfor Construction Products and Construction Types
W TT FPA Leipzig GmbH Testing, Inspection and Certification Authorityfor Construction Products and Construction Types Leipzig Institute for Materials Research and Testing Business Division III - Dipl.
More informationMA 39 VFA Vienna, 21 June 2013
Nevoga GmbH. Znaimer Strasse 4 83395 Freilassing Germany (Logo) City of Municipal Authorities of the City of MUNICIPAL DEPARTMENT (MA) 39 Inspections, Monitoring and Certifications office of the City of
More informationMFPA Leipzig GmbH. Companion Sheet No. GS6.1/ Translation of the original German document GS6.1/
MFPA Leipzig GmbH Testing, Inspection and Certification Authority for Construction Products and Construction Types Center for Innovation and Calculation Dr.-Ing. Susanne Reichel Work Group - FEM Dr.-Ing.
More informationMFPA Leipzig GmbH Testing, inspection and certification body for building materials, building products and buiiding systems
Testing, inspection and certification body for building materials, building products and buiiding systems Division III - Structural FIre Protection Dipi.-Ing. Sebastian Hauswaldt Team 3.2 - Fire Behaviour
More informationAnalysis Joint sound insulation of filler materials
Analysis Joint sound insulation of filler materials Testing Report 167 43780/Z2 Basis ift regulation SC-01 determination of joint sound insulation degree of 2002 Diagram Applicant Hanno-Werk GmbH & Co.
More informationTEST REPORT e/BDM100/H-2
Materialprüfungsanstalt Universität Stuttgart Postfach 801140 D-70511 Stuttgart Notified Body 0672 TEST REPORT 14-9028238e/BDM100/H-2 01.09.2014 ORDER: CLIENT: Execution of leakage tightness test at a
More informationabridged report analysis of climate conditions in crawl spaces with high insulated wooden floor plates for the prevention of structural damages
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbh, Hans-Weigel-Str. 2 b, 04319 Leipzig Bereich IV Bauphysik AG: Wärme- und Feuchteschutz www.mfpa-leipzig.de Fakultät für
More informationAnalysis of climate conditions in crawl spaces with high insulated wooden floor plates for the prevention of structural damages
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbh, Hans-Weigel-Str. 2 b, 04319 Leipzig Bereich IV Bauphysik AG: Wärme- und Feuchteschutz www.mfpa-leipzig.de Fakultät für
More informationCast glass. Environmental Product Declaration (EPD) Patterned, wired, solar and U-profiled glasses. short version. Declaration code: EPD-LPG-GB-28.
Environmental Product Declaration (EPD) short version Glasfabrik Lamberts GmbH & Co. KG Cast glass Patterned, wired, solar and U-profiled glasses Basic principles: DIN EN ISO 14025 EN15804 Company-EPD
More informationREPORT. dust binding capacity of Cyber Clean as a function of temperature. Report number: Part 2. Industriezone 27 CH-3210 Kerzers
GUI Gesellschaft für Umwelt- und Innenraumanalytik mbh REPORT dust binding capacity of Cyber Clean as a function of temperature Berliner Platz 12 D- 41061 Mönchengladbach Phone: +49 / 2161 / 823 92-0 Fax:
More informationTEST REPORT e/AT100/H-2
Materialprüfungsanstalt Universität Stuttgart Postfach 801140 D-70511 Stuttgart Notifizierte Stelle 0672 TEST REPORT 14-9028335e/AT100/H-2 20.09.2014 ORDER: Execution of leakage tightness test at a wall
More informationResults Please see enclosure with detailed results. The results include an additional test for Chromium VI.
Country Chic Paint Ltd 4-6 2994 Boys Road V9L 6W4 Duncan BC Canada Att: Rosanne Korteland Eurofins Product Testing DK-8464 Galten Denmark Tel. +45 70 22 42 76 Fax +45 70 22 42 75 migration@eurofins.dk
More informationTEST REPORT e/UDM100/H-2
Materialprüfungsanstalt Universität Stuttgart Postfach 801140 D-70511 Stuttgart Notifizierte Stelle 0672 TEST REPORT 14-9028335e/UDM100/H-2 20.09.2014 ORDER: CLIENT: Execution of leakage tightness test
More informationEvidence of Performance
Evidence of Performance Air permeability, Watertightness and wind load Test Report No. 15-003209-PR02 (PB-F01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions
More informationPolicies and strategies for the development of geothermal energy in Europe
Institut für Energetik und Umwelt Institute for Energy and Environment Forschung, Entwicklung, Dienstleistung für - Energie - Wasser -Umwelt Policies and strategies for the development of geothermal energy
More informationTest Report No
Test Report No. 13.0.32506 (=13.HIN.32506 ZN) VA/VL/sm Applicant : Eco Leap Technologies India Pvt. Ltd. 484F, Kamaraj Road Uppilipalayam Post 641015 Coimbatore, Tamil Nadu INDIA Date of order : 22/10/2013
More informationDECLARATION OF PERFORMANCE
DECLARATION OF PERFORMANCE DoP: 0112 for fischer termoz CN 8 / fischer termoz CN 8 R / fischer termoz CNplus 8 (Plastic anchors for use in concrete and masonry ) EN 1. Unique identification code of the
More informationTest Report no.262/ October 2004 pages 9. Dr.-Ing. M. Junk, Dipl.-Chem. M. Knabe Tel (0351) , Fax (0351)
ILK Dresden Test Report no.262/2004 07 October 2004 pages 9 Compatibility of Vespel SP1 with C 3 F 8 Customer CERN Order No. CA 1334564 Responsible Dr.-Ing. M. Junk, Dipl.-Chem. M. Knabe Tel (0351) 4081-750,
More informationQuality Safety Innovation. European Engineered Construction Systems Association e.v.
Quality Safety Innovation European Engineered Construction Systems Association e.v. 01 Editorial 02 02 introduction ECS AN ASSOCIATION PRESENTS ITSELF 04 04 06 06 07 10 11 area of activity PARTICIPATION
More informationAnnex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH German Accreditation Body Annex the Accreditation Certificate D-K-18351-01-00 according DIN EN ISO/IEC 17025:2005 Period of validity: 2017-05-24 2018-10-27 Date of issue:
More informationTest Report no. 094/ April 2007 pages 10. Compatibility of Gylon with Perfluorpropane (C 3 F 8 )
ILK Dresden Test Report no. 094/2007 18 April 2007 pages 10 Compatibility of Gylon with Perfluorpropane (C 3 F 8 ) Customer CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CH-1211 GENEVE 23 Order No. CA
More informationmethodologies and regulatory requirements focus RED St f M j Stefan Majer Kiew, October 25, 2012.
Carbon footprint basics an overview of GHG methodologies and regulatory requirements focus RED St f M j Stefan Majer Kiew, October 25, 2012. A short introduction to the DBFZ Non-profit research institute,
More informationCRT 2 NEWS. Interpretative Documents from the Commission
CRT 2 NEWS Subject: Interpretative Documents from the Commission 1 Introduction The legal service of the European commission published documents called Interpretative Documents. These documents clarify
More informationDetail catalogue for multistory timber buildings
Short report for the research project Detail catalogue for multistory timber buildings Research Institution: Technische Universität München Univ.-Prof. Dr.-Ing. Stefan Winter Project management: Dipl.-Ing.
More information*) This is a translation of Test Report dated 07 August Window system M 9400 SOFTLINE PLUS Frame material: Aluminium
Test report No. 105 22754e *) *) This is a translation of Test Report 105 22754 dated 07 August 2001. Date of report 18 June 2007 ALUMIL - MILONAS ALUMINIUM INDUSTRY S.A. INDUSTRIAL AREA GR-61100 Kilkis
More informationIf this is the case, cementitious mortar coatings will provide effective and long-term protection against the growth of bacteria and mould.
PRODUCT INFORMATION TW PAGEL - MORTAR FOR DRINKING WATER AREAS REPAIR SYSTEM POSTFACH 11 05 23 POSTFACH 11 05 23 D-45335 ESSEN WOLFSBANKRING 9 45355 ESSEN Germany TELEFON +49 201 68504-0 TELEFAX +49 201
More informationProceedings of the International Conference on Building Envelope Design and Technology, Graz Advanced Building Skins 2015
René Stein, Dipl.-Ing. project manager, Miriam Kleinhenz, Dipl.-Ing., Stefan Winter, Univ.-Prof. Dr.-Ing. Technische Universität München, Chair for timber structures and buildung construction, Germany,
More informationSoftware for Optimizing
Fraunhofer Institute for Material Flow and Logistics IML PUZZLE Software for Optimizing Loading Units and Transport Units PUZZLE has been optimizing the shipping space on load carriers such as containers,
More informationConcrete Masonry Unit Samples 45 & 46
Concrete Masonry Unit Samples 45 & 46 Please Note: The CMU specimens are contained in a total of four boxes. Two boxes for Sample 45 and two boxes for Sample 46. DO NOT mix samples. Each unit is labeled,
More informationEvidence of Performance Joint sound reduction of filling material
Evidence of Performance Test Report No. 13-002455-PR01 (PB Z6-K02-04-en-01) ift Rosenheim 13.09.2013 Client Soudal N. V. Everdongenlaan 18-20 2300 Turnhout Belgium Product Designation Thickness of sealant
More informationASTM D 4541 ADHESION STRENGTH PERFORMANCE TEST REPORT. Rendered to: BAUTEX SYSTEMS. PRODUCT: AMB 20-WN Liquid Applied Membrane
ASTM D 4541 ADHESION STRENGTH PERFORMANCE TEST REPORT Rendered to: BAUTEX SYSTEMS PRODUCT: AMB 20-WN Liquid Applied Membrane Report No: Report Date: 08/30/13 Report Retention Date: 07/23/14 130 Derry Court
More informationSUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia. Hollow chamber profile - plastic Profile combination: Casement-frame
Evidence of Performance Test Report No. 16-002359-PR02 (PB 01-K20-06-en-01) Client Product SUNCE Marinkovic d.o.o. Lepenicki bulevar br.39 34 000 Kragujevac Serbia Hollow chamber profile - plastic Profile
More informationMULTI-MONTI -plus and MULTI-MONTI
MULTI-MONTI -plus and MULTI-MONTI Fire experts report for use in masonry wall Screw anchors MMS-plus and MMS in masonry walls KS, KSL and Mz IEA IEA GMBH & CO. KG ELIGEHAUSEN - ASMUS - HOFMANN HAUPTSTRAßE
More informationStamping green - Green Certifications for Green Airports. Hermann Blomeyer 29 th November 2017
Stamping green - Green Certifications for Green Airports Hermann Blomeyer 29 th November 2017 Munich - Montreal Source: Google Maps 2 Aerial View of Munich Airport 3 Munich Airport facts and figures (2016)
More informationPrefabricated window with integrated technology for refurbishments Window Machine. Short report on funded project SWD
Lehrstuhl für Baukonstruktion und Baustoffkunde Fakultät für Architektur Technische Universität München Prefabricated window with integrated technology for refurbishments Window Machine Short report on
More informationThis TRANSLATION of the German original is not verified by the MPA Stuttgart / Universität Stuttgart. P-BWU
This TRANSLATION of the German original is not verified by the MPA Stuttgart / Universität Stuttgart. Material Testing Institute PO Box 801140 D-70511 Stuttgart Testing, monitoring and certifying body
More informationDetermination of the gel content of cross-linked ethylene-vinyl acetate (EVA) based material
Determination of the gel content of cross-linked ethylene-vinyl acetate (EVA) based material Method developed by Photovoltaik Institut Berlin AG (PI Berlin), based on soxhlet extraction 3 rd Ed, July 2011
More informationReport No
Hohenstein Textile Testing Institute Schloss Hohenstein 74357 Bönnigheim EKON - 91 Ltd. Kapitan Raicho Nikolov Str. 11 7012 Rousse BULGARIA Hohenstein Textile Testing Institute GmbH & Co. KG Schloss Hohenstein
More informationWe, the undersigned, agree that the City of Gatineau must estimate the work as described above in paragraph justification ADDRESS OWNER'S NAME
"ANNEX A" PETITION APPLICATION FOR ADDING A SIDE WALK RUE FELIX-LECLERC CONDITIONS: All owners and residents of the street affected by the change must be consulted Over 50% of owners and residents affected
More informationPROLiGNIS TECHNOLOGY AND CONCEPT RAW MATERIALS REFERENCE - BAYERNFONDS BESTENERGY 1
PROLiGNIS ENERGIE CONSULTING GMBH & CO. KG 2009 17. November...01...PROLiGNIS...02...TECHNOLOGY AND CONCEPT...03...RAW MATERIALS...04...REFERENCE - BAYERNFONDS BESTENERGY 1...05...ENVIRONMENT AND CLIMATE
More informationDeclaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011
Item code:aje01 and AJE31 Manufacturer:Tecfi S.p.A. - S.S. Appia, km 193-81050 Pastorano (CE), Italy 1. Intended use Product-type: Metal anchor for use in concrete Anchor type: Technical description of
More informationThe future is distributed.
Information brochure The future is distributed. Competence Network Distributed Energy Technologies Foreword Solutions for a distributed energy supply. 02 Distributed supply solutions become more and more
More informationDESIGNING PRODUCTIONS FOR CLEANLINESS
FRAUNHOFER INSTITUTe For manufacturing engineering and automation ipa DESIGNING PRODUCTIONS FOR CLEANLINESS 1 Introduction Especially in the automobile and supplier industry, cleanliness requirements have
More informationLake Constance 5D-Conference Automatic Generation of 4D- Schedules for reliable Construction Management
Automatic Generation of 4D- Schedules for reliable Construction Management 1 Dr.-Ing. Jochen Hanff Geschäftsführer ceapoint aec technologies GmbH Dipl.-Ing. (FH), MBA Jürgen Melzner Zentrale Kalkulation
More informationC L A S S I F I C A T I O N R E P O R T
C L A S S I F I C A T I O N R E P O R T IN ACCORDANCE TO EN 13501-2:2007+A1:2009 Load-bearing slab with a cantilevered balcony slab connected to an Isokorb K50S-CV30-V8-H160 Classification report No.:
More informationRequest for Review 15 MW grid-connected wind power project by MMTC in Karnataka (1797)
TÜV NORD CERT GmbH P.O. Box 10 32 61 45032 Essen CDM Executive Board TÜV NORD CERT GmbH Langemarckstrasse 20 45141 Essen Phone: +49 201 825-0 Fax: +49 201 825-2517 Info.tncert@tuev-nord.de www.tuev-nord-cert.com
More informationUSE OF SCC FOR A TUNNEL OF THE CITYTUNNEL MALMÖ PROJECT WITH 120 YEARS OF LIFE CYCLE
USE OF SCC FOR A TUNNEL OF THE CITYTUNNEL MALMÖ PROJECT WITH 120 YEARS OF LIFE CYCLE Dr. Frank Abel (1) and Michael Willmes (2) (1) MCG, Malmö City Tunnel Group HB, Sweden (2) Bilfinger Berger AG, Germany
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-28259-2 SOUTH AFRICAN NATIONAL STANDARD Concrete masonry construction Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911
More informationYour Customer No.: Contact person Ext. Our ref. Date Jutta Secker dr.dh / se 05 th May, 2008 TEST REPORT
FORSCHUNGSINSTITUT HOHENSTEIN PROF. DR. JÜRGEN MECHEELS SCHLOSS HOHENSTEIN D-74357 BÖNNIGHEIM Toray Textiles Europe Ltd. Mr. Chris Else Crown Farm Way, Forest Town Institute for Hygiene and Biotechnology
More informationBS 476: Part 3: 2004 test on SureSeal EPDM 1.2mm on a plywood deck
BS 476: Part 3: 2004 test on SureSeal EPDM 1.2mm on a plywood deck Prepared for: Flex-R Ltd Unit 5 Central Park Bellfield Road High Wycombe Bucks HP13 5HG 5 th December 2012 Test report number 281504B
More informationFRANK I bar spacers & special spacers
FRANK I bar spacers & special spacers Bar spacers are used to ensure that the concrete cover specified for structures and structural elements made of reinforced concrete is maintained, both before and
More informationClassification report Airbourne sound insulation of building elements
Classification report Airbourne sound insulation of building elements Test report 161 32407/Z9e*) *) This is a translation of the test report No. 161 32407/Z9 dated 9 th October 2006 Client Reynaers Aluminium
More informationTÜV Rheinland Energie und Umwelt GmbH
Report No. K 1682 2015 B1 Verification of the ErP requirements according to: Energy Performance acc. COMMISSION REGULATION (EU) No 813/2013 (Ecodesign directive 2009/125/EC) and acc. COMMISSION DELEGATED
More informationCERTIFICATE. Entsorgungsfachbetrieb. Heimerle + Meule GmbH Dennigstraße Pforzheim. Baden-Württemberg. Entsorgungsfachbetrieb
CERTIFICATE Entsorgungsfachbetrieb Heimerle + Meule GmbH Dennigstraße 16 75179 Pforzheim BadenWürttemberg Registry number: HRB 500126 Registry Court: Amtsgericht Mannheim is, with regard to the locations,
More informationEvidence of Performance. Class 4. Class E900. Class C3 / B3. Test Report No PR02. DOMIS d.o.o. Miokovci bb Cacak Serbia
Evidence of Performance Test Report No. 13-004033-PR02 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features DOMIS d.o.o. Miokovci
More informationAlways. Reliable. Tight. Cable sealing system Cable entry system KES-M90. cablepipebuildingentry+
Always. Reliable. Tight. Cable sealing system Cable entry system KES-M90 cablepipebuildingentry+ Cable entry system KES-M90 KES-M90-D Features and technical data: pressure-tight ducting system up to 2.5
More informationA Guide to Solid Wall Insulation
A Guide to Solid Wall Insulation www.nationalinsulationassociation.org.uk What is Solid Wall Insulation? Houses built before 1930 (and some built later) usually have either solid masonry w alls, concrete
More informationPrint View CD Bipolar Discharge System. Model Variations. CD2000TypeA. Bipolar discharge unit with higher mixed air flow.
Bipolar Discharge System Model Variations CD2000TypeA Bipolar discharge unit with lower mixed air flow CD2000TypeB Bipolar discharge unit with higher mixed air flow Page 1 of 7 Version: September 13, 2018
More informationREFERENCE PROJECT. Night shifts for the Roter Turm. PCI supports night-time tiling at Chemnitz shopping centre
Page 1 of 13 PCI supports night-time tiling at Chemnitz shopping centre Night shifts for the Roter Turm After 16 years of operation, the Galerie Roter Turm shopping centre in Chemnitz has been modernized
More informationInstitut für Bautenschutz, Baustoffe und Bauphysik
Schriftenreihe Heft 101/2017 Daimlerstraße 18 70736 Fellbach Tel.: (0711) 645 80 845 Fax: (0711) 645 80 846 E-Mail: info@rieche-schuerger.de Internet: www.rieche-schuerger.de Ingenieure und Sachverständige
More informationFORSCHUNGSVEREINIGUNG KALK-SAND EV
FORSCHUNGSVEREINIGUNG KALK-SAND EV Short Description Development of a Recycled Masonry Unit using Masonry Waste Material Manufactured and using Normal Calcium Silicate Production Technologies Project number:
More informationSupplier Self-Assessment
Supplier Self-Assessment Dear supplier, by following questionnaire we would like to ask you to provide us with some basic information/data about your company. As first step within our supplier approval
More informationBRE Global Test Report
BRE Global Test Report BS 476: Part 3: 2004 + A1: 2006 + A2: 2007 External fire exposure to roofs test on SolFit Top Loader. Prepared for: SolFiT Ltd Date: 19 November 2016 Report Number: P105772-1000
More informationTech Spec 21. Capping and Compressive Strength Testing Procedures for Concrete Pavers. Background
Tech Spec 21 Capping and Compressive Strength Testing Procedures for Concrete Pavers Background First approved in 1982, ASTM C936 Standard Specification for Solid Interlocking Concrete Paving Units (ASTM
More informationInvoicing Process Change Agreement
Number: Invoicing Process Change Agreement Dealpoint Number: Invoicing Process Change Agreement XXXXXXX This Invoicing Process Change Agreement (the Invoicing Agreement ) is entered into between Microsoft
More informationDECLARATION OF PERFORMANCE. No EN
DECLARATION OF PERFORMANCE No. 0004 EN 1. Unique identification code of the product-type: 2. Intended use/es: Product Plastic anchors for use in concrete and masonry Intended use/es Screwed-in plastic
More informationRevision 1 of EN Changes and news Klaus Berner 25. Oct. 2013
The European Association for Panels and Profiles Revision 1 of EN 14509 Changes and news Klaus Berner 25. Oct. 2013 EN 14509 valid version EN 14509:2006: valid version Date of applicability of the standard
More informationRoad and Transportation Research Association. Working Group Aggregates, Unbound Pavements
Road and Transportation Research Association Working Group Aggregates, Unbound Pavements Technical Delivery Terms for Aggregates in Road Construction R 1 TL Gestein-StB 04 Edition 2004/Version 2007 Translation
More informationOnly a few railway operators are providing intermodal transport services within or from/to Bulgaria;
HaCon Ingenieurgesellschaft mbh Lister Straße 15 30163 Hannover HaCon Ingenieurgesellschaft mbh Addressed to See Invitation List Lister Straße 15 30163 Hannover Deutschland Telefon +49 511 336 99-0 Fax
More informationSupervision Report /2018/03. Kronospan-MOFA Hungary Ltd. P.O. BOX Mohäcs, Hungary
EPHS SUCCESS BY QUALITY Entwicklungs- und Prueflabor Holztechnologie GmbH Zellescher Weg 24 01217 Dresden Germany Kronospan MOFA Hungary Ltd. Mr. Gabor Katoli P.O. BOX 92 7701 Mohäcs Hungary E-Mail: gabor.katoli@kronospan-mofa.hu
More informationYour Our reference/name Tel. Fax extension Date/Document Page
TÜV SÜD Industrie Service GmbH 80684 Munich Germany DAP-PL-2885.99 DAP-IS-2886.00 DAP-PL-3089.00 DAP-PL-2722 DAP-IS-3516.01 DPT-ZE-3510.02 ZLS-ZE-219/99 ZLS-ZE-246/99 Your Our reference/name Tel. Fax extension
More informationConcrete Reinforcing Bar Samples 23 & 24
Concrete Reinforcing Bar Samples 23 & 24 Please Note: $ The rebar specimens are contained in a total of two boxes. $ One box for Sample 23 and one for Sample 24. $ There are three specimens for each sample.
More informationFairContacts. For the world s largest trade fair. for the international Embedded Community
FairContacts For the world s largest trade fair for the international Embedded Community ig Busi embedded world From February 26, 2019 to February 28, 2019 in Nuremberg 1,021 exhibitors and over 32,000
More informationSimulation in production and logistics. Efficient planning well-based decisions with VDI Guidelines
Simulation in production and logistics Source: SimPlan AG, Maintal Efficient planning well-based decisions with VDI Guidelines VDI Society Production and Logistics Department of Factory Planning and Operation
More informationHIGH GRADE. The economical alternative to steel fibers and steel mesh.
HIGH GRADE The economical alternative to steel fibers and steel mesh. Advantages Compressive strength 4 Flexural strength 5 Early shrinkage crack characteristics 6 Shrinkage characteristics 7 Water penetration
More informationEvidence of Performance Joint sound reduction of filling material
Evidence of Performance Test Report No. 13-002455-PR02 (PB-K05-04-en-01) ift Rosenheim 10.09.2013 Client Soudal N. V. Everdongenlaan 18-20 2300 Turnhout Belgium Product Designation Density Special features
More informationInfrastructure. Infrastructure. Logistics infrastructural facilities in the Saarland
89 Infrastructure Logistics infrastructural facilities in the Saarland Logistics infrastructural facilities in the Saarland 90 GSE Germany GmbH The GSE Group is headquartered in Avignon, France, and is
More informationPRESS RELEASE
PRESS RELEASE 14-01-53 dated 15 January 2014 Vacuum Insulation Panels (VIP) stress test Research report demonstrates the suitability of use of Since the subjects of energy conservation and reducing CO
More informationGeneral Building Inspectorate Approval
Certified translation from to English Approval body construction products and types of construction Building Technology Board General Building Inspectorate Approval A statutory body jointly financed by
More informationBuilding Climate Long-term measurements to determine the effect on the moisture gradient in timber structures
Short report for the research project: Building Climate Long-term measurements to determine the effect on the moisture gradient in timber structures Research Institution: Technische Universität München
More informationEvidence of Performance Airborne sound insulation of building components
Evidence of Performance Airborne sound insulation of building components Test Report No. 14-000251-PR01 (PB Z09-H01-04-en-02) Client Product Designation PRESS GLASS SA Nowa Wies Kopalniana 9 42-262 Poczesna
More information66'-5 5/8" T/PARAPET 62'-9 5/8" ROOF 39'-7 3/4" LEVEL 4 +28'-5 7/8" LEVEL 3 +17'-4" LEVEL 2 +7'-1 3/8" MEZZANINE -2'-0" RESIDENTIAL
15 1 1 1 '-5 5/" '- 5/" AA '-5 5/" '- 5/" UDRB ELEVATION KEYNOTES. HORIZONTAL METAL PANEL 1. HORIZONTAL METAL PANEL. METAL PANEL. CEMENT BOARD 1. CEMENT BOARD 5. CEMENT BOARD. CEMENT BOARD. METAL PANEL.
More informationSTRUCTURAL NOTES MISCELLANEOUS COLD-FORM STEEL FRAMING MASONRY SITE WORK CAST IN PLACE CONCRETE
STRUCTURAL NOTES MISCELLANEOUS COLD-FORM STEEL FRAMING MASONRY AA 0009 707 US Hwy. 9 Palm Harbor, FL 68 Phone 77. 78. 7 Fax 77. 78. 66 SITE WORK CAST IN PLACE CONCRETE OPEN WEB STEEL JOISTS AND JOIST GIRDERS
More informationThe story behind. You probably know that TMT was founded in 2003 as a 50/50 partnership between DANGO & DIENENTHAL and PAUL WURTH
The story behind You probably know that TMT was founded in 2003 as a 50/50 partnership between DANGO & DIENENTHAL and PAUL WURTH You may be aware that our head offices are located in Siegen (Germany) and
More informationEvidence of Performance Calculation of thermal transmittance
Evidence of Performance Test Report No. 14-001048-PR01 (PB-K20-06-en-01) Client Product ELVIAL S.A. Aluminium Extrusion 25th Km national road, Thessaloniki 61100 Kilkis Greece Thermal insulated metal profiles
More informationMagnesium Sheet Metal production today
Magnesium Metal production today Production of Magnesium Metal through rolling or strip casting Advantages High productivity Good quality / reproducibility Large sheet width Disadvantages High invest High
More informationPROTECTING BUILDINGS AGAINST FLOOD RISK DEMOUNTABLE BAUER-IBS BARRIERS
PROTECTING BUILDINGS AGAINST FLOOD RISK DEMOUNTABLE BAUER-IBS BARRIERS An effective protection from flooding to domestic properties is now available Flood catastrophes occur ever more frequently in Europe.
More informationHelmut F Giesa Consulting Engineer : Senior Project + Contract /Claim Manager + Supervisor
Dipl.-Ing. Univ., Prof. Eng., MSc. Helmut F Giesa Consulting Engineer : Senior Project + Contract /Claim Manager + Supervisor Concrete Works GiS-Converter Station, Ghadames / Libya Steel works Ship hull
More informationDETERMINATION OF SHAPE FACTORS FOR MASONRY UNITS
13 th International Brick and Block Masonry Conference Amsterdam, July 4-7, 2004 DETERMINATION OF SHAPE FACTORS FOR MASONRY UNITS I. Beer 1, P. Schubert 2 Abstract In the testing of masonry units for compressive
More informationTool and equipment test for Honda
Tool and equipment test for Honda Testing resistance spot welding equipment Project Management Dipl.-Ing. Bernd Schmidt Head of Testing and Development Report and execution of practical work Vehicle Technician
More informationExperimental study of composite column and wall systems for impact resistance
Experimental study of composite column and Dipl.-Ing. Alexander Britner Abteilung Stahl- und Leichtmetallbau Leitung: Prof. Dr.-Ing. T. Ummenhofer KIT Universität des Landes Baden-Württemberg und nationales
More informationDLG Test Report JOHN DEERE GmbH & Co. KG. HarvestLab. (SW 51 LKS 08/17) Ingredients in liquid cattle manure.
DLG Test Report 6814 JOHN DEERE GmbH & Co. KG HarvestLab (SW 51 LKS 08/17) Ingredients in liquid cattle manure www.dlg-test.de Overview A test mark DLG-APPROVED for single, value-determining criteria is
More informationEuropean Technical Assessment ETA-17/0741 of 29/08/2017
ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011
More informationDLG Test Report JOHN DEERE GmbH & Co. KG. HarvestLab (SW 132 LKS 09/17) Ingredients in liquid cattle manure.
DLG Test Report 6811 JOHN DEERE GmbH & Co. KG HarvestLab 3000 (SW 132 LKS 09/17) Ingredients in liquid cattle manure www.dlg-test.de Overview A test mark DLG-APPROVED for single, value-determining criteria
More informationNo. Target audience Date Number of pages 014 Affected users
GS Elektromedizinische Geräte Hauswiesenstraße 26 Tel. +49 8191 65722-0 Fax +49 8191 65722-22 info@corpuls.com www.corpuls.com No. Target audience Date Number of pages 014 Affected users 2014-11-17 8 Affected
More informationGeneral Pricelist. Swissport Cargo Services Deutschland GmbH. Station Leipzig
Swissport Cargo Services Deutschland GmbH -Headquarters- Cargo City South, Bldg. 558 B D-60549 Frankfurt Telephone: +49 69 219797-10 Fax: +49 69 219797-99 email: fra.hq-sec@swissport.com Swissport Cargo
More informationEvidence of Performance Burglar resistance
Test Report No. 16-001785-PR02 (PB-C01-05-en-02) Client ALUMIL S.A. Industrial Area 61100 Kilkis Greece Product Burglar resistant Smart SD77 panel door RC 2 Designation SMART DOORS Overall dimensions (W
More informationGreen Gas and the EU ETS. Stefan Majer, Beike Sumfleth, Katja Oehmichen, Christiane Hennig, Daniela Thrän
Green Gas and the EU ETS Stefan Majer, Beike Sumfleth, Katja Oehmichen, Christiane Hennig, Daniela Thrän 4th European Biomethane Conference - Afternoon Session I: Ireland 20 th September 2018 Introduction
More informationBrock White Canada Attn: Mr Nigel J. Lilley Street Edmonton AB T5V 1L8 Canada
BBG Bauberatung Geokunststoffe GmbH & Co. KG Gewerbestraße 2 32339 Espelkamp Brock White Canada Attn: Mr Nigel J. Lilley 12835 170 Street Edmonton AB T5V 1L8 Canada Gewerbestraße 2 32339 Espelkamp Telephone
More informationMax Frank GmbH & Co. KG PRODUCT CHARACTERISTICS. Product Rating. LEED Category LEED Credit max. influenced score Degree of fulfillment %
MANUFACTURER PRODUCT NAME PRODUCT CHARACTERISTICS Shear connetor for the transmission of shear forces in expansion joints. Mitterweg 1 94339 Leiblfing Deutschland Product Rating LEED Category LEED Credit
More information