STO POREN BRICK VENEER DRAWING REGISTER

Size: px
Start display at page:

Download "STO POREN BRICK VENEER DRAWING REGISTER"

Transcription

1 STO DRAWING REGISTER Drawing Description Drawing No. Drawing Register PB Introduction Series 000 Sto Poren Brick Veneer Introduction PB 004 Sto Poren Brick Veneer Narrow Widths & Stress Points PB 005 Sto Poren Brick Veneer Timber Lintel Calculation Tables PB 006 Panel Layout Series 100 Sto Poren Brick Veneer/Sto Poren Plaster System - Isometric PB 100 Sto Poren Brick Veneer/Sto Armat Plaster System - Isometric PB 101 Foundation Series 200 Sto Poren Brick Veneer Foundation Slab-on-ground PB 200 Sto Poren Brick Veneer Foundation Timber Floor PB 201 Sto Poren Brick Veneer Ribraft Floor System / Edge Detail PB 202 Walls Series 300 Sto Poren Brick Veneer External Corner PB 300 Sto Poren Brick Veneer Internal Corner PB 301 Sto Poren Brick Veneer Vertical Control Joint PB 302 Sto Poren Brick Veneer Galvanised Fixing Brackets PB 303 Sto Poren Brick Veneer Standard Lintel Connection PB 304 Sto Poren Brick Veneer Lintel Opening (unsupported) PB 305 Sto Poren Brick Veneer Lintel Opening (supported) - Opt 1 PB 306 Sto Poren Brick Veneer Lintel Opening (supported) - Opt 2 PB 307 Wall Penetrations & Fittings Series 350 Sto Poren Brick Veneer Pipe Penetration Detail - up to 150mm PB 350 Sto Poren Brick Veneer Light Fitting/Fixing Detail PB 351 Sto Poren Brick Veneer Tap Fiting/Fixing Detail PB 352 Sto Poren Brick veneer Handrail Bracket/Fixing Detail PB 353 Sto Poren Brick Veneer Meterbox - head, sill & jamb PB 354 Sto Poren Brick Veneer Downpipe Saddle Fixing & Wiring Details PB 355 Sto Poren Brick Veneer Fan Vent Detail PB 356 Joinery Series 400 Sto Poren Brick Veneer Alu.Joinery - Head Detail - for openings up to 2000M PB 400 Sto Poren Brick Veneer Alu.Joinery - Head Detail - for openings over 2000M PB 401 Sto Poren Brick Veneer Alu.Joinery - Sill Detail - Opt 1 PB 402 Sto Poren Brick Veneer Alu.Joinery - Sill Detail - Opt 2 PB 403 Sto Poren Brick Veneer Alu.Joinery - Jamb Detail PB 404 Sto Poren Brick Veneer Entry Door Head Detail PB 405 Sto Poren Brick Veneer Entry Door Threshold Detail PB 406 Sto Poren Brick Veneer Entry Door Jamb Detail PB 407 Sto Poren Brick Veneer Sliding Door Head Detail PB 408 Sto Poren Brick Veneer Sliding Door Threshold - Concrete Floor PB 409 Sto Poren Brick Veneer Sliding Door Jamb Detail PB 410 THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. PAGE 1 OF 3 DRAWING REGISTER PB 001

2 STO DRAWING REGISTER Drawing Description Drawing No. Parapets, Balustrades, Decks Series 500 Sto Poren Brick Veneer Parapet/Metal Flashing Detail PB 500 Sto Poren Brick Veneer Parapet/Plastered Detail PB 501 StoPoren Brick Veneer Parapet and/or Encl.Balustrade Wall Junction - Plan View PB 502 StoPoren Brick Veneer Flexible Flashing Install - Isometric PB 503 StoPoren Brick Veneer Metal Saddle Flashing & Cap Install - Isometric PB 504 StoPoren Brick Veneer StoFlexyl Meshed Saddle Flashing Install - Isometric PB 505 StoPoren Brick Veneer StoFlexyl Meshed Waterproofing Cap Install - Isometric PB 506 StoPoren Brick Veneer Balustrade/Encl.Deck PB 507 StoPoren Brick Veneer Cantilevered Slatted Deck PB 508 StoPoren Brick Veneer Non Cantilevered Slatted Deck PB 509 StoPoren Brick Veneer Independent Slatted Deck PB 510 StoPoren Brick Veneer Timber Beam / Pergola Detail PB 511 Soffit Series 600 Sto Poren Brick Veneer Flat Soffit/Wall Junction PB 600 Sto Poren Brick Veneer Raking Soffit/Wall Junction PB 601 Sto Poren Brick Veneer Face Fixed Fascia PB 602 Sto Poren Brick Veneer Raking Soffit PB 603 Sto Poren Brick Veneer Raking Soffit - Sto upvc Control Joint PB 604 Sto Poren Brick Veneer Soffit at Window/Door Head PB 605 Roof Series 700 Sto Poren Brick Veneer Apron Flashing PB 700 Sto Poren Brick Veneer Parallel Apron Flashing PB 701 Sto Poren Brick Veneer Inter-storey Transverse (Apron)Roof/Stopend PB 702 Sto Poren Brick Veneer Inter-storey Flat (Membrane)Roof/Stopend Flashing PB 703 Sto Poren Brick Veneer Inter-storey Roof Stop End Flashing - PlanView PB 704 Sto Poren Brick Veneer Roof Penetration Gutter (Masonry Tile) Detail PB 705 Sto Poren Brick Veneer Roof Parallel Hidden Gutter PB 706 Sto Poren Brick Veneer Face Fixed Fascia/Barge PB 707 Sto Poren Brick Veneer Face Fixed Fascia/Membrane Roof PB 708 Sto Poren Brick Veneer Roof/Wall Ridge PB 709 Sto Poren Brick Veneer Framed Chimney PB 710 THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. PAGE 2 OF 3 DRAWING REGISTER PB 002

3 STO DRAWING REGISTER Drawing Description Drawing No. Dissimilar Material Weatherboard Series 800 Sto Poren Brick Veneer/Weatherboard - Ext.Corner PB 800 Sto Poren Brick Veneer/Weatherboard - Int.Corner PB 801 Sto Poren Brick Veneer/Weatherboard - Vertical Joint Flashing PB 802 Sto Poren Brick Veneer/Weatherboard - Horizontal Junction - Opt 1 PB 803 Sto Poren Brick Veneer/Weatherboard - Horizontal Junction - Opt 2 PB 804 Brick Series 810 series not issued Fibre Cement Sheet Series 820 Sto Poren Brick Veneer/FC Sheet - Ext.Corner PB 820 Sto Poren Brick Veneer/FC Sheet - Int.Corner PB 821 Sto Poren Brick Veneer/FC Sheet - Vertical Junction PB 822 Sto Poren Brick Veneer/FC Sheet - Horizontal Junction - Opt 1 PB 823 Sto Poren Brick Veneer/FC Sheet - Horizontal Junction - Opt 2 PB 824 Concrete Block Series 830 series not issued Manufactured Stone - Schist & Natural Stone Series 840 series not issued Profile Metal Series 850 Sto Poren Brick Veneer/Horiz.Profiled Metal - Ext.Cnr PB 850 Sto Poren Brick Veneer/Horiz.Profiled Metal - Int.Cnr PB 851 Sto Poren Brick Veneer/Horiz.Profiled Metal - Vertical Junction - Opt 1 PB 852 Sto Poren Brick Veneer/Horiz.Profiled Metal - Vertical Junction - Opt 2 PB 853 Sto Poren Brick Veneer/Horiz.Profiled Metal - Horizontal Junction - Opt 1 PB 854 Sto Poren Brick Veneer/Horiz.Profiled Metal - Horizontal Junction - Opt 2 PB 855 Sto Poren Brick Veneer/Vertical Profiled Metal - External Corner PB 856 Sto Poren Brick Veneer/Vertical Profiled Metal - Internal Corner PB 857 StoTherm Panel EIFS Series 860 Sto Poren Brick Veneer/StoTherm - External Corner PB 860 Sto Poren Brick Veneer/StoTherm - Internal Corner PB 861 Sto Poren Brick Veneer/StoTherm - Vertical Joint PB 862 Sto Poren Brick Veneer/StoTherm - Horizontal Junction - Opt 1 PB 863 Sto Poren Brick Veneer/StoTherm - Horizontal Junction - Opt 2 PB 864 DISSIMILAR JOINERY Series 870 TIMBER JOINERY Sto Poren Brick Veneer Timber Window Joinery - Head Detail PB 870 Sto Poren Brick Veneer Timber Window Joinery - Sill Detail PB 871 Sto Poren Brick Veneer Timber Window Joinery - Jamb Detail PB 872 Sto Poren Brick Veneer Timber Door Joinery - Concrete Floor/Threshold Detail PB 873 THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. PAGE 3 OF 3 DRAWING REGISTER PB 003

4 CONSTRUCTION THE HAS BEEN APPRAISED FOR USE AS A VENEER BRICK CLADDING FOR BUILDINGS WITHIN THE FOLLOWING SCOPE: THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1 PARAGRAPH 1.1 IN TERMS OF FLOOR AREA, WITH A MAXIMUM OF TWO STORIES; AND, WITH A MAXIMUM HEIGHT OF BRICK VENEER OF 7.5 M ABOVE THE SUPPORTING FOUNDATION, EXCEPT THAT AT GABLE ENDS AND SOME PIERS THIS HEIGHT MAY BE UP TO 10.0 M, AND A MAXIMUM HEIGHT OF 4.0 M ABOVE A ROOF LINE; AND, WITH A DEPTH OF CAVITY OF BETWEEN 40 MM AND 75MM; AND, WITH A RISK SCORE OF 0-20, CALCULATED IN ACCORDANCE WITH NZBC ACCEPTABLE SOLUTION E2/AS1 TABLE 2; AND, WITH TIMBER FRAMING CONSTRUCTED ON SLAB-ON-GROUND IN ACCORDANCE WITH NZS 3604 AND/OR CONCRETE MASONRY FOUNDATION CONSTRUCTED IN ACCORDANCE WITH NZS 4229; AND, SITUATED IN NZS 3604 BUILDING WIND ZONES UP TO AND INCLUDING EXTRA HIGH. BRICK DRY CAVITY CONSTRUCTION NO SOFFIT OR WINDOW BRICK VENTS POREN upvc JOINERY FLASHINGS POREN 2400 x 200 x 75mm STEEL REINFORCED LINTELS FOR OPENINGS POREN 600 x 200 x 75mm LIGHTWEIGHT BIG BRICKS POREN BRICK MORTAR FOR STRENGTH PLASTER BRICK PLASTER INCORPORATING: 1. S-PROTECT WS 205 SEALER TO SEAL BARE BRICKS 2. STOPOREN PLASTER 25kg BAG MINERAL MESHED BASECOAT PLASTER FOR STRAIGHTENING WALLS, CAN BE MACHINE APPLIED. 3. STOPLEX W SEALER 10lt CONTAINER EUROPEAN CONSOLIDATION SEALER 4. STOLIT K or MP COLOURED FINISHING RENDER 25kg PAIL EUROPEAN FIBRE REINFORCED NON-CEMENT COLOURED FINISHING RENDER AVAILABLE IN 1.0/1.5/2.0/3.0mm SIZED TEXTURE AND MP or MP NATURAL COLOURED SPONGE RENDER. 5. STOCOLOR : MAXICRYL MATT FACADE PAINT 15lt PAIL : LASTIC SATIN FACADE PAINT 15lt PAIL : LOTUSAN MINERAL RESIN PAINT 15lt PAIL 6. STOARMAT MIRAL PLASTER CAN ALSO BE USED FOR TWENTY (20) YEAR WARRANTY INTRODUCTION PB 004

5 E A, B or G A C C D G D D D H E D B E D D D D D F A B C D E F G H POREN LINTEL OVER OPENINGS AND TO REINFORCED STRESS POINTS OVERLAP LINTEL MIN 600mm PAST ANY NARROW WIDTHS OR STRESS POINTS CONTINUOUS GALVANISED SHELF BRACKET REQUIRED ON PARALLEL SLOPING ROOFS WIRE REINFORCED IN EXTERIOR CENTRES POREN LINTELS WITH POREN 310mm WIDE SHELF BRACKETS AT JOINS ON OPENINGS OVER 2000mm LONG OR AT INTER-STOREY PARALLEL ROOFS MINIMUM BRICK WIDTH 200mm CONTROL JOINT REQUIRED EVERY 6.0 LINEAL METERS WHERE A CONTROL JOINT OCCURS AT H, FINISH POREN LINTEL ON POREN SHELF BRACKET FINISH LINTEL ON POREN SHELF BRACKETS FOR CONTINUOUS CONTROL JOINTS NOTE: BRICK TIES REQUIRED AT 400mm VERTICALLY & 600mm HORIZONTALLY, AT ALL LINTEL JOINS OR TERMINATIONS, 150mm MAX.FROM CONTROL JOINTS SCALE 1:10 NARROW WIDTHS & STRESS POINTS PB-005

6 FLITCH BEAM CALCULATION TABLES TO SUPPORT POREN LINTEL AT OPENINGS FLITCH BEAM CALCULATION TABLES PB-006

7 PLASTER TIMBER FRAMING TO NZS 3604 WALL UNDERLAY MEETING REQUIREMENTS E2/AS1 BRICK VENEER S PROTECT WS205 SILANE POREN PLASTER 2/3mm PLUS: STO EUROPEAN MESH 4/7mm POREN PLASTER 2mm STOPLEX W SEALER STOLIT K & MP COLOURED FINISHING RENDER STO COLOR MAXICRYL/STOLASTIC COLOR WEEP HOLES OR VENTS TO ACHIEVE VENTILATION 1000sq mm PER LINEAL METRE ( 8 x 75mm 600mm CENTRES MIN ) MIN BRICK LAP 150mm STO PLASTER DRIP EDGE POREN MORTAR FLUSH TOOL JOINTS REBATE WITH STOFLEXYL OR LIQUID DPM PLASTER SCALE 1:20 PB-100

8 STOARMAT PLASTER TIMBER FRAMING TO NZS 3604 WALL UNDERLAY MEETING REQUIREMENTS E2/AS1 BRICK VENEER S PROTECT WS205 SILANE BASECOAT: POREN PLASTER 3/4mm STOARMAT CLASSIC PLASTER PLUS: STO EUROPEAN MESH STOARMAT CLASSIC PLASTER STOLIT K & MP COLOURED FINISHING RENDER STO COLOR MAXICRYL/STOLASTIC COLOR WEEP HOLES OR VENTS TO ACHIEVE VENTILATION 1000sq mm PER LINEAL METRE ( 8 x 75mm 600mm CENTRES MIN ) MIN BRICK LAP 150mm STO PLASTER DRIP EDGE POREN MORTAR FLUSH TOOL JOINTS REBATE WITH STOFLEXYL OR LIQUID DPM STOARMAT PLASTER SCALE 1:20 PB-101

9 BRICK TIES SCREW FIXED TO FRAMING IN FIRST COURSE THEN AT 400mm CTRS VERTICALLY & 600mm CTRS HORIZONTALLY WEEP HOLES OR VENTS TO ACHIEVE VENTILATION mm² PER LINEAL METER (8x75mm ctrs min.) STO FLEXYL BRUSH COAT APPLIED TO REBATE 5-10mm OVERHANG STO upvc 5mm DRIP EDGE 100mm MIN. TO PAVED INSULATION AS PER NZBC - clause H1 DPM CONCRETE SLAB/REINFORCING AS PER NZS 3604 OR ENGINEER SPECIFIC DESIGN 50mm MIN. UNPAVED PLASTER FOUNDATIONS TO DRIP EDGE - SCORE A LINE IN BASECOAT AND FINISH FLUSH. DONOT MESH OVER DRIP EDGE STOPOREN FOUNDATION SLAB-ON-GROUND SCALE 1:5 PB 200

10 BRICK TIES SCREW FIXED TO FRAMING IN FIRST COURSE THEN 400mm CTRS VERTICALLY & 600mm CTRS HORIZONTALLY WEEP HOLES OR VENTS TO ACHIEVE VENTILATION mm² PER LINEAL METER (8x75mm ctrs min.) STO FLEXYL BRUSH COAT APPLIED TO REBATE STO upvc CONTROL JOINT AT REBATE BETWEEN VENTS 100 X SERIES MASONRY SOLID FILLED USED WHERE X IS GREATER THAN 110mm 20 SERIES CONC.BLOCK SOLID FILLED. VENTILATION OPENINGS AS PER NZS 3604:2011 STOPOREN CONCRETE SLAB/REINFORCING AS PER NZS 3604 OR ENGINEER SPECIFIC DESIGN CONC.BLOCK FOUNDATION/TIMBER FLOOR SCALE 1:5 PB 201

11 BRICK TIES SCREW FIXED TO FRAMING IN FIRST COURSE THEN AT 400mm CTRS VERTICALLY & 600mm CTRS HORIZONTALLY WEEP HOLES OR VENTS TO ACHIEVE VENTILATION mm² PER LINEAL METER (8x75mm ctrs min.) STO FLEXYL BRUSH COAT APPLIED TO REBATE mm OVERHANG STO upvc 5mm DRIP EDGE 100mm MIN. TO PAVED 220 CONCRETE SLAB/REINFORCING AS PER NZS 3604, SPECIFIC DESIGN OR ENGINEER (SED) Reinforcing not shown for clarity 50mm MIN. UNPAVED 300 PLASTER FOUNDATIONS TO DRIP EDGE - SCORE A LINE IN BASECOAT AND FINISH FLUSH. DONOT MESH OVER DRIP EDGE RIBRAFT POLYSTYRENE POD INSTALLATION IN ACCORDANCE TO FIRTH RIBRAFT CONSTRUCTION DETAILS SCALE 1:5 STOPOREN RIBRAFT FLOOR / EDGE DETAIL PB 202

12 WALL UNDERLAY CONTINUOUS AROUND CORNERS PLASTER BRICK VENEER STO PREMESHED CORNER BEAD BRICK TIE 300mm MAX.FROM CORNER BRICK VENEEER EXTERNAL CORNER SCALE 1:2 PB 300

13 BRICK TIES 300mm MAX. FROM CORNER WALL UNDERLAY CONTINUOUS AROUND CORNERS BRICK VENEER PLASTER INTERNAL CORNERS ARE DOUBLE LAPPED MESHED TIMBER FRAMING TO NZS 3604 SCALE: 1:2 INTERNAL CORNER PB 301

14 150mm MAX. 8-12mm INSTALL STO upvc CONTROL JOINT WITH MS SEALANT IN STOARMAT CLASSIC MESH COAT 8-12mm NOTE: VERTICAL CONTROL JOINTS AT MAX.6 METERS CTRS OR WHERE THE HEIGHT OF THE WALL CHANGES BY MORE THAN 20%. HORIZONTAL CONTROL JOINTS ONLY REQUIRED AT DISSIMILAR MATERIAL JUNCTIONS. 6.0M max. VERTICAL CONTROL JOINT PB 302

15 TIMBER FRAMING TO NZS3604 WALL UNDERLAY 40mm MIN.CAVITY TIMBER BEAM ENGINEERED GALV.STEEL 'H' or 'U' BRACKET. ALLOW 12mm MIN.GAP BETWEEN PLASTER & SEAL BRACKET WITH MS SEALANT OVER PEF ROD. USE A 'L' BRACKET FOR JOISTS AT RIGHT ANGLES REFER TO ENGINEERS SPECIFIC STRUCTURAL REQUIREMENTS NOTE: MANUFACTURED GALV.STEEL 'H' or 'U' BRACKET FOR PARALLEL CONNECTION. USE 'L' BRACKET FOR RIGHT ANGLED CONNECTIONS GALVANISED FIXING BRACKETS SCALE 1:5 PB 303

16 TOP PLATE 25x1mm STRAP WITH 6/30x2.5 NAILS INTO BOTH LINTEL & STUD. ALTERNATIVE FIXING CAPACITY IS A 7.5Kn CONNECTION - 2/90 x 3.15 END NAILS LINTEL DOUBLING STUD TO BE CONTINOUS BETWEEN THE BOTTOM PLATE AND THE UNDERSIDE OF THE LINTEL USE 6/90 x 3.15 END NAILS - POSTION TWO AT TOP, MIDDLE & BOTTOM NOTE: SEE PB 307 FOR OPENINGS OVER 2.0M STANDARD LINTEL CONNECTION SCALE 1:10 PB 304

17 REFER TO POREN SPAN TABLES FOR MITEK or PRYDA TIMBER LINTEL SIZES C B B 2000 opening A MAX.OPENING IS 2000mm A. BRICK VENEER HEIGHT (MAX.WALL HEIGHT 7.5M GABLE ENDS UP TO 10M B. LAP (200mm MIN.) C. OPENING LINTEL LENGTH CALCULATION C + (2xB) = LINTEL LENGTH EG: 2000mm + (2x200mm) = 2400mm LINTEL BRICK TIES 600mm MIN.CTRS - SPANS OVER 2000mm REQUIRE POREN SHELF BRACKETS LINTEL OPENING (unsupported) SCALE 1:50 PB 305

18 REFER TO POREN SPAN TABLES FOR MITEK or PRYDA TIMBER LINTEL SIZES 1 2 E 1 2 E D B B 4000 opening LINTEL BRICK CTRS MIN. APART AT EACH MORTARED LINTEL JOINT. INCLUDE ENDS A. BRICK VENEER HEIGHT (MAXIMUM WALL HEIGHT 7.5M. GABLE ENDS UP TO 10M B. LAP (200mm MIN.) C. OPENING D. LENGTH OF WHOLE LINTEL (2400mm) E. LENGTH OF PARTIAL LINTEL LINTEL LENGTH CALCULATION OPENING + (2xB) = OVERALL LINTEL LENGTH OVERALL LINTEL LENGTH - D + E E / 2 = 1 2 E EG: LINTEL LENGTH CALCULATION 4000mm + (2x200) = 4400mm 4400mm mm = 2000mm 2000 / 2 = 1000mm LINTEL OPENING (supported) - OPT 1 SCALE 1:50 PB 306

19 REFER TO POREN SPAN TABLES FOR MITEK or PRYDA TIMBER LINTEL SIZES E 1 B 6000 opening 2 E LINTEL BRICK CTRS MIN. APART AT EACH MORTARED LINTEL JOINT. INCLUDE ENDS B A A. BRICK VENEER HEIGHT (MAXIMUM WALL HEIGHT 7.5M. GABLE ENDS UP TO 10M B. LAP (200mm MIN.) C. OPENING D. LENGTH OF WHOLE LINTEL (2400mm) E. LENGTH OF PARTIAL LINTEL LINTEL LENGTH CALCULATION OPENING + (2xB) = OVERALL LINTEL LENGTH OVERALL LINTEL LENGTH - D + E E / 2 = 1 2 E EG: LINTEL LENGTH CALCULATION 6000mm + (2x200) = 6400mm 6400mm mm = 4000mm 4000 / 2 = 2000mm LINTEL OPENING (supported) - OPT 2 SCALE 1:50 PB 307

20 BLOCKING TO SUPPORT PIPE WALL UNDERLAY 40-75mm CAVITY BRICK VENEER MORTAR FLUSH POINT JOINTS PIPE OR OTHER PENETRATION SLOPED DOWNWARDS 8/10mm SEALANT BEAD ON PEF ROD BETWEEN PIPE AND PLASTER BRICK TIES SCREW FIXED TO FRAMING - SPACING 400mm CTRS VERTICALLY & 600mm HORIZONTALLY PLASTER 100mm min. STAR CUT FLASHING TAPE CUT LINES STOPOREN PIPE PENETRATION DETAIL SCALE 1:5 PB 350

21 WALL UNDERLAY 50 x 3mm EPDM WASHER GASKETS REQUIRED AROUND FIXINGS AND PLATE TO PROVIDE WEATHERTIGHTNESS 40-75mm CAVITY PLASTER BRICK VENEER MORTAR FLUSH POINT JOINTS BRICK TIES SCREW FIXED TO FRAMING - SPACINGS 400mm CTRS VERTICALLY & 600mm HORIZONTALLY NOTE: LIGHTS AND LIGHT WEIGHT FITTINGS CAN BE FIXED USING MASONRY FIXINGS WITH 40mm MIN. EMBEDMENT LIGHT FITTING/FIXING DETAIL SCALE 1:2 PB 351

22 FLASHING TAPE 100mm ONTO UNDERLAY 25mm ONTO TAP CONNECTION PROVIDE TIMBER BLOCKING AT TAP NOTE: STO QUADER BLOCK IS A HIGH DENSITY NON COMPRESIBLE EPS POLY BLOCK WITH 4x28mm PLYWOOD INSERTS. FACING FRAMING SIZE 645x645x145x60/FOUR SECTIONS PER BLOCK, USE A FIXING PLATE TO AVOID POINT LOADS TAP FITTING/FIXING DETAIL SCALE 1:2 PB 352

23 HANDRAIL BRACKET/FIXING DETAIL SCALE 1:2 PB 353

24 PLASTER BRICK TIES SCREW FIXED TO FRAMING DPC or BATTEN TAPED TO UNDERLAY AT 15 SLOPE ABOVE METERBOX FINISHING EDGE TO HEAD & JAMBS 8 TIMBER FRAMING TO NZS3604 INTERNAL LINING 8mm AIRSEAL ON PEF ROD BY BUILDER FLASHING TAPE100mm MIN. ONTO WALL UNDERLAY & 50mm ONTO METER BOX ROUND ALL SIDES MS SEALANT OVER STO JOINT SEAL TAPE TO PERIMETER OF METERBOX CHAMFER BRICK AT SILL 15 MIN. 8 8mm AIRSEAL ON PEF ROD BY BUILDER TIMBER FRAMING TO NZS3604 INTERNAL LINING SCALE 1:2 METERBOX PB 354

25 WALL UNDERLAY 40-75mm CAVITY BRICK VENEER MORTAR FLUSH POINT JOINTS DOWNPIPE/CLIP - 1.2M CTRS MAX. 1. DOWNPIPE/CLIP - SADDLE DETAIL upvc OR OTHER DOWNPIPE - SIZE REFER NZBC E1 Table 5 CABLE/WIRING MS SEALANT ALL AROUND PVC CONDUIT SLEEVE INSTALLED AT 5 DEGREES DOWNWARD SLOPE 2. WIRING PENETRATION DETAIL NOTE: ENSURE THE AMOUNT OF PENETRATIONS THROUGH THE IS KEPT TO A MINIMUM. THE WEATHERSEALING OF ALL WIRING, ETC AS SHOWN, IS THE RESPONSIBILITY OF THE APPLICABLE TRADE DOWNPIPE SADDLE FIXING & WIRING DETAILS SCALE 1:2 PB 355

26 40-75mm DRAINED CAVITY TIMBER FRAMING AS PER NZS 3604 TIMBER BLOCKING AS REQUIRED BRICK VENEER MS SEALANT TO HEAD & SIDES FLEXIBLE FLASHING TAPE EXTRACTION PIPE SLOPE DOWNWARDS AT MINIMUM 5 FAN COVER MS SEALANT/PEF ROD AT PIPE JUNCTION (STO SEAL TAPE ON FLEXIBLE PIPES) STO upvc 6mm FINISHING EDGE TIMBER BLOCKING AS REQUIRED NOTE: LEAVE 40mm DRAINAGE GAP IN SEALANT AT BOTTOM OF FAN COVER. INSTALL FLASHING TAPE 100mm AROUND PIPE ONTO WALL UNDERLAY AND WRAP 25mm ROUND PIPE. FOR FLEXIBLE PIPES, TAPE PIPE TO FAN COVER, APPLY STO JOINT SEAL, TAPE AROUND TAPE BEFORE PLACING IN HOLE. ALWAYS FINISH PLASTER BEFORE INSTALLING FAN COVER FAN VENT DETAIL SCALE 1:2 PB 356

27 WALL UNDERLAY 40-75mm DRAINED CAVITY BRICK VENEER PLASTER MORTAR FLUSH POINT JOINT BRICK TIES SCREW FIX TO FRAMING - SPACING 200mm MAX. FROM OPENING TIMBER LINTEL AS PERPOREN SPAN TABLE OR SPECIFIC DESIGN 35mm MIN. 50mm BRICK VENEER JOINERY LINTEL STO upvc ADJUSTABLE FOOT TRAY BASE, EXTN & FRONT FLASHING TAPE ONTO WALL UNDERLAY AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX NOTE: OPENINGS OVER 2000mm REQUIRE POREN SHELF BRACKETS FLASHING TAPE TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1 DETAILS STOPOREN 5 MIN. 5mm GAP REQUIRED SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES ALUMINIUM WINDOW HEAD FLASHING WITH 15 SLOPE AND 10mm COVER AT WINDOW HEAD ALUMINIUM WINDOW JOINERY ALU.JOINERY/HEAD DETAIL - FOR OPENINGS UP TO 2000M SCALE 1:2 PB 400

28 BRICK VENEER 40-75mm DRAINED CAVITY MORTAR FLUSH POINT JOINT BRICK 600mm MAX.CTRS & 150mm APART AT MORTARED LINTEL JOINTS PLASTER TIMBER LINTEL AS PERPOREN SPAN TABLE OR SPECIFIC DESIGN 25 35mm MIN. WALL UNDERLAY RETURNED INTO OPENINGS & FLASHING TAPE AT CORNERS BRICK VENEER JOINERY LINTEL STO 75mm upvc VENTED BRICK CAP - CUT AROUND BRACKETS, INSTALL HORIZ.BATTEN TO RESTRICT CAVITY TO 25mm LINTEL AT REBATE AROUND SHELF BRACKET ADDITIONAL LAYER FLASHING TAPE LAPPED ALU.HEAD FLASHING STO 75mm upvc VENTED BRICK CAP - CUT AROUND BRACKETS, INSTALL HORIZ.BATTEN TO RESTRICT CAVITY TO 25mm AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX NOTE: OPENINGS OVER 2000mm REQUIRE POREN SHELF BRACKETS FLASHING TAPE TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1 DETAILS STOPOREN SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES ALUMINIUM WINDOW HEAD FLASHING WITH 15 SLOPE AND 10mm COVER AT WINDOW HEAD ALUMINIUM WINDOW JOINERY NOTE: WHERE THE CAVITY IS LARGER THAN 45mm PROVIDE H3.2 PACKER BEHIND THE POREN SHELF BRACKET. WHERE PACKERS ARE USED THE POREN SHELF FIXINGS LENGTH MUST BE INCREASED BY THE THICKNESS OF THE PACKER ALU.JOINERY/HEAD DETAIL - FOR OPENINGS OVER 2000M SCALE 1:2 PB 401

29 DRESSED PINE PRIMED REVEALS & ARCHITRAVES AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX APPLY WS 205 SEALER TO SILL & JAMBS BEFORE PLASTERING WANZ CONTINOUS SUPPORT BAR & LOCATION WINDOW BRACKET MS SEALANT STO upvc JOINERY FLASHING SILL 15 SLOPE OVERHANG 30-50mm FLASHING TAPE CONTINUOUS AROUND SILL AND JAMBS - REFER E2/AS1 BRICK VENEER PLASTER STOPOREN ALU.JOINERY/SILL DETAIL - OPT 1 SCALE 1:2 PB 402

30 DRESSED PINE PRIMED REVEALS & ARCHITRAVES AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX APPLY WS 205 SEALER TO SILL & JAMBS BEFORE PLASTERING MS SEALANT STO upvc JOINERY FLASHING WANZ CONTINOUS SUPPORT BAR & LOCATION WINDOW BRACKET FLASHING TAPE CONTINUOUS AROUND SILL - REFER E2/AS1 MORTAR FLUSH POINT JOINT 40-75mm DRAINED CAVITY BRICK VENEER PLASTER STOPOREN ALU.JOINERY/SILL DETAIL - OPT 2 SCALE 1:2 PB 403

31 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX & PACKER WALL UNDERLAY LAPPED & STAPLED ON INSIDE EDGE. FLASHING TAPE OVER AS PER E2/AS1 100mm UP JAMBS ALUMINIUM WINDOW JOINERY BRICK TIES SCREW FIX TO FRAMING - SPACINGS 200mm MAX. FROM OPENING BRICK VENEER PLASTER STO upvc JOINERY FLASHING MS SEALANT APPLY WS 205 SEALER TO JAMBS & SILL BEFORE PLASTERING NOTE: STO upvc JOINERY FLASHING TO BE INSTALLED DURING CONSTRUCTION STOPOREN ALU.JOINERY/JAMB DETAIL SCALE 1:2 PB 404

32 WALL UNDERLAY MORTAR FLUSH POINT JOINT BRICK TIES SCREW FIX TO FRAMING - SPACINGS 200mm MAX. FROM OPENING 40-75mm DRAINED CAVITY BRICK VENEER JOINERY LINTEL PLASTER FLASHING TAPE OVER HEAD FLASHING ONTO WALL UNDERLAY STO upvc 75mm VENTED BRICK CAP WITH POREN PANEL ADHESIVE ALUMINIUM WINDOW HEAD FLASHING WITH 15 SLOPE AND 10mm COVER AT WINDOW HEAD MIN. 5mm GAP REQUIRED SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES ALUMINIUM DOOR JOINERY 5 INSTALL HORIZONTAL BATTEN TO RESTRICT CAVITY TO 25mm THIN BED MORTAR AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX NOTE: OPENINGS OVER 2000mm REQUIRE POREN SHELF BRACKETS - REFER DWG PB 407 SCALE 1:5 STOPOREN ENTRY DOOR HEAD DETAIL PB 405

33 CLADDING BEYOND ALU.OPEN IN DOOR JOINERY 30X30X3mm ALU.SUPPORT ANGLE FIXED THROUGH CONCRETE, EDPM WASHER BETWEEN STOFLEXYL AND ANGLE AT EVERY FIXING APPLY MIN. 2 COATS STO FLEXYL BRUSH COAT TO REBATE mm REBATE TO SLAB EDGE WHERE DOOR OCCURS, NEATLY FORM FALL AS SHOWN - MIN mm TURN-UP FLASHING TAPE 100mm MIN.AT TRIMMER STUDS AIR SEAL TIMBER TRIM & FLOOR FINISH SCALE 1:5 STOPOREN ENTRY DOOR THRESHOLD DETAIL PB 406

34 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX & PACKER DRESSED PINE PRIMED REVEALS & ARCHITRAVES WALL UNDERLAY LAPPED & STAPLED ON INSIDE EDGE. FLASHING TAPE OVER AS PER E2/AS1 100mm UP JAMBS BRICK VENEER PLASTER BRICK TIES SCREW FIX TO FRAMING - SPACINGS 200mm MAX.FROM OPENING ALUMINIUM DOOR JOINERY MS SEALANT STO upvc JOINERY FLASHING APPLY WS 205 SEALER TO JAMBS & SILL BEFORE PLASTERING NOTE: STO upvc JOINERY FLASHING TO BE INSTALLED DURING BLOCK CONSTRUCTION STOPOREN ENTRY DOOR JAMB DETAIL SCALE 1:5 PB 407

35 MORTAR FLUSH POINT JOINT BRICK 600mm MAX.CTRS & 150mm APART AT MORTARED LINTEL JOINTS BRICK VENEER JOINERY LINTEL 40-75mm DRAINED CAVITY PLASTER 300x75x6mm GALV.POREN SHELF BRACKET FIXED WITH COACH BOLTS OR SCREWS AT JOINTS STO upvc 75mm VENTED BRICK CAP. INSTALL HORIZ.BATTEN TO RESTRICT CAVITY TO 25mm ALUMINIUM WINDOW HEAD FLASHING WITH 15 SLOPE AND 10mm COVER AT WINDOW HEAD. SEALANT REQ.FOR VH & EXTRA HIGH WIND ZONES 25 35mm MIN. WALL UNDERLAY RETURNED INTO OPENINGS & FLASHING TAPE AT CORNERS AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX ALUMINIUM DOOR JOINERY NOTE: WHERE THE CAVITY IS LARGER THAN 45mm PROVIDE H3.2 PACKER BEHIND THE POREN SHELF BRACKET. WHERE PACKERS ARE USED THE POREN SHELF FIXINGS LENGTH MUST BE INCREASED BY THE THICKNESS OF THE PACKER OPENINGS OVER 2000mm REQUIRE POREN SHELF BRACKETS. REBATE BRICKS SO POREN SHELF BRACKETS FINISH FLUSH WITH BRICK STOPOREN SLIDING DOOR HEAD DETAIL SCALE 1:5 PB 408

36 CLADDING BEYOND ALU.SLIDING DOOR JOINERY 30X30X3mm ALU.SUPPORT ANGLE FIXED THROUGH CONCRETE, EDPM WASHER BETWEEN STOFLEXYL AND ANGLE AT EVERY FIXING APPLY MIN. 2 COATS STO FLEXYL BRUSH COAT TO REBATE mm REBATE TO SLAB EDGE WHERE DOOR OCCURS, NEATLY FORM FALL AS SHOWN - MIN mm TURN-UP FLASHING TAPE 100mm MIN.AT TRIMMER STUDS AIR SEAL TIMBER TRIM & FLOOR FINISH SCALE 1:5 STOPOREN SLIDING DOOR THRESHOLD - CONCRETE FLOOR PB 409

37 WALL UNDERLAY LAPPED & STAPLED ON INSIDE EDGE. FLASHING TAPE OVER AS PER E2/AS1 100mm UP JAMBS AIRSEAL ON PEF BACKING ROD TO ALL SIDES OF DOOR ALUMINIUM DOOR JOINERY BRICK TIES SCREW FIX TO FRAMING BRICK VENEER PLASTER APPLY WS 205 SEALER TO JAMBS & SILL BEFORE PLASTERING STO upvc JOINERY FLASHING MS SEALANT NOTE: STO upvc JOINERY FLASHING TO BE INSTALLED DURING BRICK CONSTRUCTION STOPOREN SLIDING DOOR JAMB DETAIL SCALE 1:5 PB 410

38 PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING AND 15mm H3 PLY - PACKED TO FALL PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL 5 REFER TABLE 7 - E2/AS1 Z Z REFER TABLE 7 - E2/AS1 H3.1 TIMBER PACKER CUT TO FALL 7.5/9.0mm VENTCLAD or MONOTEK SHEET CLADDING OVER 20mm DRAINED CAVITY & WALL UNDERLAY STOARMAT PLASTER FINISH CARRY MESH/PLASTER UP TO TOP EDGE WALL UNDERLAY 40-75mm DRAINED CAVITY MORTAR FLUSH JOINTS BRICK TIES SCREW FIXED TO FRAMING PLASTER 1. INSTALL METAL SADDLE FLASHING AT WALL JUNCTION 2. ENSURE TOP IS TEMPORARILY WATERPROOFED BEFORE COMMENCING PLASTERING 3. METAL CAPPING EXCLUDING DRIP EDGE MUST OVERLAP SHEET BY 50mm MIN.IN LOW, MED or HIGH WIND ZONE, 70mm MIN.IN VERY HIGH, 90mm MIN.IN EXTRA HIGH WIND ZONES PARAPET/METAL FLASHING DETAIL SCALE 1:5 PB 500

39 POREN CAP AT 10 OVERSEATS WALLS, GLUE TO POREN WALL & BRICK VENEER CLADDING H3.1 CAPPING PLATE CUT TO 10 SLOPE WITH FLASHING TAPE OR ROOFING UNDERLAY STO PREMESHED upvc ADJUSTABLE CORNERS OVERLAY OF STO FLEXYL MESHED MEMBRANE UNDER MESH COAT TO TOP & SIDES, 75mm MIN.DOWNTURN OVER LEVELITE BASE COAT POREN FIXING 20mm DRAINED CAVITY POREN PANEL PLASTER WALL UNDERLAY CONTINUOUS OVER TOP OF WALL FRAME 40-75mm DRAINED CAVITY BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH JOINTS PLASTER NOTE: STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 WATERPROOF MEMBRANE AS REQUIRED BY E2/AS1 EXTRA HIGH WIND ZONES REQUIRE A RIGID UNDERLAY. FLASHING MUST BE TAPED TO RIGID UNDERLAY PARAPET/PLASTERED DETAIL SCALE 1:5 PB 501

40 WINDOW TRIMMING STUD 75mm MIN. 75mm MIN. FLASHING TAPE ON INTERNAL CORNERS 75mm BOTH WAYS 7.5/9.0mm VENTCLAD or MONTEK SHEET 20mm DRAINED CAVITY mm MIN. TO FACE OF WINDOW OR DOOR JAMB STUD BALUSTRADE WALL UNDERLAY LAPPED AROUND CORNER 40-75mm CAVITY STOTHERM CONSTRUCTION PARAPET and/or ENCL.BALUSTRADE TO WALL - PLAN SCALE 1:5 PB 502

41 WALL FRAMING WALL UNDERLAY FLEXIBLE FLASHING TAPE DRESSED UP AND SECURELY ADHERED TO WALL UNDERLAY AT REAR OF CAVITY CONTINUE FLASHING TAPE 100mm OVER H3.1 CAPPING PLATE H3.1 CAPPING PLATE CUT AT 10 SLOPE DRAIN FORMED IN CORNER WITH FLASHING TAPE FLEXIBLE FLASHING INSTALL - ISOMETRIC SCALE 1:5 PB 503

42 50mm MIN. 50mm MIN. 8mm EXPANSION GAP BETWEEN PARAPET CAP AND SADDLE FLASHING - USE MS SEALANT RIVET THROUGH TOP OF CAP TO SADDLE FLASHING. MS SEALANT TO RIVETS EXTENT OF SADDLE FLASHING 2 LINES OF SEALANT METAL PARAPET CAP FLASHING 100mm MIN. A. SADDLE FLASHING B. PARAPET CAP WALL UNDERLAY PLACE CAP FLASHING OVER SADDLE FLASHING - REFER TO E2/AS1 FIGURE 12 FOR CAP FIXING DETAILS. H3.1 CAPPING PLATE CUT TO A FALL WITH FLASHING TAPE OR ROOFING UNDERLAY NOTE: SADDLE FLASHING INSTALLED AFTER CAVITY. 50x50mm INTERNAL CNR FLASHING FROM BEHIND SADDLE EXTENDED TO BOTTOM OF WALL PANELS ON EACH BUILDING FACE METAL SADDLE FLASHING & CAP INSTALL PB 504

43 OVERLAY OF STOFLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES 75mm MIN.DOWNTURN OVER LEVELITE BASE COAT LEVELLITE BASECOAT PLASTER POREN PANEL CAP FLASHING TAPE OR ROOF UNDERLAY OVER H3.1 CAPPING PLATE H3.1 TIMBER CAPPING PLATE CUT TO A FALL - MIN BRICK VENEER WALL UNDERLAY STO 20mm VH CAVITY BATTENS PANEL NOTE: APPLY STOFLEXYL MESHED WATERPROOFING OVER BASECOAT STOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BY E2/AS1 SCALE 1:5 STOFLEXYL MESHED SADDLE FLASHING - ISOMETRIC PB 505

44 E2/AS1 REQUIRES BALCONY & PARAPET WALLS TO BE OFFSET FROM MAIN WALL PLAIN TO ALLOW FOR SADDLE FLASHINGS BASECOAT PLASTER, STOPOREN BRICK VENEER CAP OVER H3.1 CAPPING PLATE CUT TO 10 SLOPE WITH A LAYER OF FLASHING TAPE or ROOFING UNDERLAY NOTE: STOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET AS/NZS4858 AS REQUIRED BY E2/AS1. ALL WALL CAPS (MIN.10 FALL ARE TO HAVE STOFLEXYL WATERPROOFING AS SHOWN OVER THE STOPOREN BRICK BASECOAT PLASTER. STOFLEXYL TO EXTEND 75mm MIN.DOWN THE WALL FACE AND ONTO ADJACENT WALLS SCALE 1:5 STOFLEXYL MESHED WATERPROOFING CAP - ISOMETRIC PB 506

45 10 POREN CAP AT 10 OVERSEATS WALLS, GLUE TO POREN WALL & BRICK VENEER CLADDING H3.1 CAPPING PLATE CUT TO 10 SLOPE WITH FLASHING TAPE OR ROOFING UNDERLAY POREN FIXING STO PREMESHED upvc ADJUSTABLE CORNERS OVERLAY OF STO FLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES, 75mm MIN.DOWNTURN OVER LEVELITE BASE COAT WALL UNDERLAY CONTINUOUS OVER TOP OF WALL FRAME 40-75mm DRAINED CAVITY 20mm DRAINED CAVITY POREN PANEL PLASTER mm drip edge MORTAR FLUSH JOINTS PLASTER STO upvc VENTED BASE CAP FULLY SUPPORTED MEMBRANE UPSTAND 20mm MIN.ANGLE FILLET DECK STRUCTURE NOTE: HANDRAIL REQUIRED WHERE BALUSTRADE IS UNDER 1000mm PARAPET/BALUSTRADE ENCL.DECK SCALE 1:5 PB 507

46 STOPOREN PLASTER 6mm STO upvc FINISHING EDGE, SEAL END PANEL WITH S PROTECT WS mm MAX.DRAINAGE STO JOINT SEAL TAPE & MS SEALANT TO TOP AND SIDES LINE OF CLADDING BETWEEN JOISTS - SHOWN DASHED, CUT AROUND JOIST 12 5 LINE OF CANTILEVER JOIST - SHOWN DASHED 5mm MIN. GAP BETWEEN STOPOREN PLASTER AND SADDLE FLASHING SOLID BLOCKING BETWEEN JOISTS 35 CONTINUOUS INTER-STOREY FLASHING STOPOREN PLASTER 6mm STO upvc FINISHING EDGE, SEAL END PANEL WITH S PROTECT WS MIN.COVER NOTE: REFER E2/AS1 Fig.16 FOR FLASHING REQUIREMENTS. PROVIDE 6-8mm WIDE SEALANT JOINT AT CLADDING/SADDLE FLASHING JUNCTION. 50mm MIN. SET DOWN FROM FLOOR OR THRESHOLD FOR CANTILEVERED SLATTED DECKS CANTILEVERED SLATTED DECK PB 508

47 MS SEALANT OVER STO JOINT SEAL TAPE BETWEEN POREN PANEL AND BRACKET FIXING CAPACITY AS PER ENGINEER 40 POREN BRICK VENEER PLASTER TIMBER BEAM TO BE FIXED AFTER PLASTERING COMPLETE 40mm GAP RECOMMENDED (12mm MIN. GAP) GALVANIZED OR STAINLESS STEEL 'H' or 'U' BRACKET, SEAL BRACKET WITH MS SEALANT OVER PEF ROD ENGINEERED TO SPECIFIC STRUCTURAL REQUIREMENTS PLASTER POREN BRICK VENEER NON CANTILEVERED SLATTED DECK SCALE 1:5 PB 509

48 INSULATION TO EXTERIOR WALLS INTERNAL LINING TIMBER FRAMING TO NZS 3604 FLOORING 12 MORTAR FLUSH POINT JOINTS BRICK TIES SCREW FIXED TO FRAMING - SPACING TO NZS mm DRAINED CAVITY PLASTER FINISHED DECK SURFACE FLOOR JOIST DECK JOIST DPC 50mm MIN.REBATE IN CONCRETE SLAB STO FLEXYL BRUSH COAT APPLIED 15-20mm FILLET TO CORNER WEEP HOLES OR VENTS TO ACHIEVE VENTILATION mm² PER LINEAL METER (8x75mm ctrs min.) STO upvc 5mm DRIP EDGE 125mm SQ.PILE - REFER NZS3604:2011 INDEPENDENT SLATTED DECK SCALE 1:5 PB 510

49 WALL UNDERLAY 40-75mm DRAINED CAVITY STOPOREN PLASTER FLASHING TAPE 100mm ONTO WALL UNDERLAY and ONTO BRACKET GALVANIZED OR STAINLESS STEEL L BRACKET ENGINEERED FOR LOAD TIMBER BEAM STO JOINT SEAL EDGE & MS SEALANT 12mm MIN.GAP NOTE: 'L' BRACKET ENGINEERED FOR LOAD. FLASHING TAPE TO BUILDING UNDERLAY IN ACCORDANCE WITH E2/AS1 FIG. 68 SCALE 1:2 TIMBER BEAM / PERGOLA DETAIL PB 511

50 VARIES MS SEALANT 6-8mm (before plastering) SECURE TOP BRICK WITH EXPANDING FOAM BRICK TIES SCREW FIX TO FRAMING - SPACINGS 400mm CTRS VERTICALLY & 600mm HORIZONATALLY WALL UNDERLAY 40-75mm DRAINED CAVITY MORTAR FLUSH POINT JOINT PLASTER NOTE: VENTING AT SOFFITS IS NOT REQUIRED WITH BRICK DRY CAVITY FLAT SOFFIT/WALL JUNCTION SCALE 1:10 PB 600

51 VARIES H3.1 PRE PRIMED & PAINTED FASCIA BOARD MS SEALANT 6-8mm (before plastering) SECURE TOP BRICK WITH EXPANDING FOAM NOTE: VENTING AT SOFFITS IS NOT REQUIRED WITH BRICK DRY CAVITY RAKING SOFFIT/WALL JUNCTION SCALE 1:10 PB 601

52 PREFINISHED METAL ROOFING OVER ROOF UNDERLAY PREFABRICATED TRUSS TOP CHORD OVERHANG * PRE FINISHED METAL E2 EAVES FLASHING, LAP mm MAX. UNDER ROOF CLADDING, TURN DOWN INTO GUTTER H3.1 PRE PRIMED & PAINTED FASCIA BOARD *50mm MIN.FASCIA COVER OVER PLASTER MS SEALANT 6-8mm ON PEF ROD SECURE TOP BRICK WITH EXPANDING FOAM BLOCK CAVITY TO PREVENT VENTILATION INTO ROOF SPACE 40-75mm DRAINED CAVITY BRICK VENEER PLASTER NOTE: VENTING AT SOFFITS IS NOT REQUIRED WITH BRICK DRY CAVITY REFER TO E2/AS1 TABLE 1 FOR RISK LEVELS. EAVE FLASHINGS ARE REQUIRED WHEN FASCIA IS 100mm OR LESS FROM WALL CLADDING AND ROOF PITCH IS LESS THAN 10 FACED FIXED FASCIA SCALE 1:10 PB 602

53 PREFINISHED METAL ROOFING OVER ROOF UNDERLAY SECURE TOP BRICK WITH EXPANDING FOAM SELECTED FIBRE CEMENT SOFFIT LINING 50x35mm MIN.METAL FLASHING 6mm MAX.GAP WITH MS SEALANT BLOCK OFF CAVITY TO PREVENT VENTILATION INTO ROOF SPACE 40-75mm DRAINED CAVITY BRICK VENEER PLASTER NOTE: VENTING AT SOFFITS IS NOT REQUIRED WITH BRICK DRY CAVITY MAX.ANGLE OF SOFFIT RESTRICTED TO BETWEEN SCALE 1:5 RAKING SOFFIT PB 603

54 PREFINISHED METAL ROOFING OVER ROOF UNDERLAY 6 35 SELECTED FIBRE CEMENT SOFFIT LINING STO upvc JOINERY CONNECTOR FINISH WITH MS SEALANT SECURE TOP BRICK WITH EXPANDING FOAM BLOCK OFF CAVITY TO PREVENT VENTILATION INTO ROOF SPACE 40-75mm DRAINED CAVITY BRICK VENEER PLASTER NOTE: VENTING AT SOFFITS IS NOT REQUIRED WITH BRICK DRY CAVITY MAX.ANGLE OF SOFFIT RESTRICTED TO BETWEEN SCALE 1:5 RAKING SOFFIT - STO upvc CONTROL JOINT PB 604

55 100mm MIN.TO FACE OF CLADDING TIMBER LINTEL AS PER NZS 3604 varies SELECTED FIBRE CEMENT SOFFIT LINING 18x18mm TIMBER BEAD AT SOFFIT, PAINTED PROVIDE AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. WALL UNDERLAY DRESSED INTO OPENING AS PER E2/AS1 DETAIL SELECTED ALUMINIUM WINDOW/DOOR JOINERY LINE OF BRICK VENEER BEYOND - SHOWN DASHED SOFFIT AT WINDOW/DOOR HEAD SCALE 1:2 PP 605

56 ROOF UNDERLAY CONTINUOUS TO TOP OF FLASHING REFER E2/AS1 TABLE 7 ROOF STRUCTURE 10 OVER 40-75mm DRAINED CAVITY BRICK TIES SCREW FIXED TO FRAMING IN FIRST COURSE THEN AT 400mm CTRS VERTICALLY & 600mm CTRS HORIZONTALLY POREN MORTAR WALL UNDERLAY or FLASHING TAPE LAPPED OVER APRON FLASHING BRICK VENEER JOINERY LINTEL STO upvc VENTED HEAD FLASHING 100x75x6mm POREN SHELF BRACKETS FIXED WITH 2/M10x75mm COACH CTRS MAX. STOP END - 10mm PAST CLADDING STO upvc DRIP EDGE 5mm GAP MAX. TURN-DOWN FOR NOTCHED PRE FINISHED METAL APRON FLASHING PREFINISHED METAL ROOFING SELECTED ROOF UNDERLAY NOTE: PROVIDE FLASHING STOPEND AT ROOF TO WALL JUNCTION TO DIVERT WATER FROM CAVITY APRON FLASHING SCALE 1:5 PB 700

57 BRICK OVER 40-75mm DRAINED CAVITY REFER E2/AS1 TABLE 7 BRICK TIES SCREW FIXED TO FRAMING IN FIRST COURSE THEN AT 400mm CTRS VERTICALLY & 600mm CTRS HORIZONTALLY POREN MORTAR BRICK STO upvc VENTED HEAD FLASHING STOP END CONTINUOUS POREN SHELF BRACKETS FIXED WITH 2/M10x75mm COACH CTRS MAX. STO upvc DRIP EDGE APRON FLASHING WITH TAPERED STOPEND TO DIVERT WATER IN GUTTER. CLADDING TO BE CAREFULLY CUT OVER STOPEND & SEALED ROOF STRUCTURE NOTE: PROVIDE FLASHING STOPEND AT ROOF TO GUTTER JUNCTION TO DIVERT WATER INTO THE GUTTER - Refer Drawing PB606 SCALE 1:5 PARALLEL APRON FLASHING PB 701

58 75 PREFINISHED METAL APRON FLASHING PREFINISHED METAL ROOFING OVER UNDERLAY SELECTED ROOF WRAP 5mm GAP MAX. FOR NOTCHED TURN-DOWN REFER E2/AS1 TABLE 7 35 ROOF UNDERLAY CONTINUOUS TO TOP OF FLASHING 50mm MIN.FASCIA BACK FLASHING - SHOWN DASHED NOTE: CONTRACTOR TO FIT STOPEND FLASHING & HEMMED FLASHING FOR FASCIAS 50mm BEHIND CLADDING, 50mm BEHIND FASCIA. STO CONTRACTOR TO APPLY FINISHED SEALANT JOINT BETWEEN FASCIA & PLASTER. UNDERLAY or FLASHING TAPE OVER FLASHING UPSTAND. PARAPETS - REFER 500 SERIES - PARAPET DETAILS INTERSTOREY TRANSVERSE (APRON) ROOF STOPEND SCALE 1:5 PB 702

59 ROOFING MEMBRANE 150mm MIN.UPSTAND, 75mm CLADDING COVER, CLADDING 35mm MIN. ABOVE MEMBRANE IF MEMBRANE IF ROOF STO STICK ON CONNECTOR or MS SEALANT JOINT ON PEF ROD BETWEEN STOPEND AND CLADDING ROOFING MEMBRANE OVER METAL STOPEND. STOPEND TO EXTEND 10mm MIN.PAST FINISHED WALL CLADDING ROOF/DECK A 75 NOTE: MEMBRANE NOT SHOWN ON STOP END FOR CLARITY A = CAVITY & FINISHED CLADDING + 10mm BRICK OVER 40-75mm DRAINED CAVITY 10 STO upvc VENTED HEAD FLASHING STOP END 10mm PAST FINISHED CLADDING BACK FLASHING 50mm BEHIND FASCIA & CLADDING FASCIA 10mm SHORT OF FINISHED CLADDING WITH MS SEALANT JOINT 10 SCALE 1:5 INTER-STOREY FLAT (MEMBRANE)ROOF STOPEND PB 703

60 0.55mm BMT PREFINISHED METAL APRON FLASHING FASCIA / CLADDING BACK FLASHING 50mm MIN.COVER STOPEND 10 FASCIA 10mm SHORT OF CLADDING - MS SEALANT JOINT FINISHED CLADDING & FASCIA MS SEALANT ON PEF RODS H3.1 PRE PRIMED & PAINTED FASCIA/BARGE BOARD 0.55mm BMT PRE FINISHED METAL FLASHING INTER-STOREY ROOF STOPEND - PLAN VIEW SCALE 1:5 PB 704

61 DRESS WALL UNDERLAY OVER GUTTER LINING BRICK TO LAP OVER UPSTAND. FINISH 50mm MIN.ABOVE GUTTER LINING ROOF UNDERLAY CARRIED DOWN OVER GUTTER LINING MASONRY ROOFING TILE 100mm MIN. 75mm MIN. LAP 50mm MIN.DEEP SELECTED GUTTER LINING CARRIED OVER ANTI-PONDING BOARD AND UP ABUTMENT FRAME ON NOG TO SUIT ANTI-PONDING BOARD LAID TO A 5 MIN.FALL GUTTER BOARD AT ABUTMENT ON NOGS TO SUIT SCALE 1:5 ROOF PENETRATION/GUTTER (Masonry Tile) DETAIL PB 705

62 ADDITIONAL LAYER OF FLASHING TAPE LAPPED OVER APRON FLASHING UPSTAND PREFINISHED METAL APRON FLASHING CONTINUOUS SHELF BRACKET FIXED TO STUDS 80mm MIN. 20mm MIN. 35mm GAP 75mm MIN.COVER 110mm MIN.TOTAL NOTE: WHERE GUTTER FINISHES WITHIN THE LENGTH OF THE WALL, STEP LOWER PART OF GUTTER OUT TO 10mm PAST THE CLADDING LINE, WHILE MAINTAINING REQ.CLEARANCES, TO ALLOW THE GUTTER TO FEED INTO THE LOWER EAVES GUTTER. - REFER Fig: 37 & Fig: 50 Incl.Section PARALLEL ROOF/HIDDEN GUTTER SCALE 1:5 PB 706

63 PRE FINISHED METAL FLASHING 70 50/90mm LAP REFER NZBC, TABLE 7 E2/AS1 BRICK OVER 40-75mm DRAINED CAVITY FACE FIXED FASCIA/BARGE SCALE 1:5 PB 707

64 SELECTED MEMBRANE FINISH OVER H3 "C" FACED PLYWOOD LAID TO 1:60MIN.FALL. GLUE & SCREW TO TIMBER JOISTS, ALL EDGES SUPPORTED ON FRAMING MIN.5mm RADIUS TO PLYWOOD 50/90mm LAP REFER NZBC, TABLE 7 E2/AS1 TAKE BOTH LAYERS 6mm PAST S/S ANGLE TO FORM DRIP EDGE PREFINISHED METAL SPOUTING AND BRACKETS H3.1 PRE PRIMED & PAINTED FASCIA/BARGE BOARD MS SEALANT ON PEF ROD CONTINOUS BATTEN OR BLOCKING TO CLOSE OFF CAVITY FROM ROOF SPACE FACE FIXED FASCIA/MEMBRANE ROOF SCALE 1:5 PP 708

65 PREFINISHED METAL FLASHING, TURN DOWN TO SUIT PROFILE PREFINISHED METAL ROOFING OVER UNDERLAY SELECTED ROOF WRAP REFER E2/AS1 TABLE 7 STO upvc FINISHING EDGE PRE FINISHED METAL FLASHING, FIXED AT SIDE ONLY 50/90mm LAP REFER NZBC, TABLE 7 E2/AS1 STO JOINT SEAL TAPE ROOF STRUCTURE BRICK TIES SCREW FIX TO FRAMING WALL UNDERLAY 40-75mm DRAINED CAVITY STOPOREN BRICK VENEER PLASTER SUSTEM ROOF/WALL RIDGE SCALE 1:5 PP 709

66 ALLOWABLE FOR LOW, MED & HIGH WIND ZONES NOT PERMITTED WHERE WIND ZONE IS CLASSIFIED AS EXTRA HIGH COVER mm MAX. REFER TO E2/AS1 Table 7 SET ONE CORNER OF UPSTAND HIGHER UP ROOF PLANE TO PROVIDE CROSS FALL mm MIN. SEPARATE ROOFING SHEET OVER 250mm MIN. HEM FOLD UNDER ROOFING PENETRATION APRON FLASHING MIN. UPSTAND 110mm SIDE COVER = 2 CRESTS 35mm GAP BETWEEN CLADDING AND FLASHING FIBRE CEMENT SHEET WALL CLADDING WALL UNDERLAY H3.1 TIMBER CAVITY BATTENS STOARMAT PLASTER WITH PREMESHED EXTERNAL CORNERS NOTE: SUITABLE FOR RECTANGULAR PENETRATIONS UP TO 1200mm WIDE. ROOF PITCH MUST BE 10 or HIGHER - REFER TO E2/AS1 TABLE 9 or 17 FOR MAX.ROOF LENGTH ABOVE PENETRATIONS. BLOCKING REQUIRED FOR PENETRATIONS OVER 200mm SCALE 1:20 FRAMED CHIMNEY STOARMAT PLASTER OVER 7.5-9mm FIBRE CEMENT SHEET CLADDING STO CAVITY BATTEN WALL UNDERLAY LAPS OVER FLASHING CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING STO upvc CLIP ON FINISHING EDGE 0.55mm BMT PREFINISHED METAL APRON FLASHING PREFINISHED METAL ROOFING OVER UNDERLAY SELECTED ROOF WRAP STOARMAT PLASTER OVER 7.5-9mm FIBRE CEMENT SHEET CLADDING STO CAVITY BATTEN WALL UNDERLAY LAPS OVER FLASHING STO CLIP ON FINISHING EDGE Table 7 NZBC LAP 250mm MIN. CAVITY CLOSER POSITIONED UNDERLAY SEPARATOR TO GIVE 15mm MIN.DRIP BETWEEN FLASHING EDGE TO CLADDING AND FRAMING. FRAME TO SUPPORT FLASHING ROOF STRUCTURE NZS 3604 SCALE 1:10 BRICK VENEER FRAMED CHIMNEY OR PENETRATION UP TO 1200mm PB 710

67 PLASTER BRICK VENEER 40-75mm DRAINED CAVITY BRICK TIES SCREW FIX TO FRAMING 50mm COVER WALL UNDERLAY CONTINUOUS AROUND CORNER FLASHING TAPE APPLIED TO UNDERLAY MIN. 75mm WIDE STO PREMESHED upvc ANGLE TO CORNERS MS SEALANT OVER STO JOINT SEAL OR PEF ROD 6mm MIN.GAP WEATHERBOARD/STO BRICK VENEER - EXT.CNR SCALE 1:2 PB 800

68 WALL UNDERLAY CONTINUOUS AROUND CORNER 40-75mm DRAINED CAVITY PACK AS REQUIRED 50mm MIN. COVER PURPOSE MADE E2/AS1 COMPLIANT METAL FLASHING BRICK TIES SCREW FIX TO FRAMING BRICK VENEER PLASTER MS SEALANT ON STO JOINT SEAL TAPE SELECTED HORIZONTAL TIMBER WEATHERBOARDS OVER 20mm DRAINED CAVITY 50mm MIN. COVER W'BOARD/ INT.CNR SCALE 1:2 PB 801

69 50mm MIN. WALL UNDERLAY BRICK TIES SCREW FIX TO FRAMING 40-75mm DRAINED CAVITY SELECTED HORIZONTAL TIMBER WEATHERBOARDS OVER 20mm DRAINED CAVITY E2/AS1 COMPLIANT HEMED METAL FLASHING MS SEALANT ON STO JOINT SEAL TAPE - 6mm MIN.GAP BRICK VENEER PLASTER PLASTER VERTICAL JOINT - W'BOARD/ SCALE 1:2 PB 802

70 BEVEL-BACK WEATHERBOARDS OVER 20mm DRAINED CAVITY FLASHING TAPE LAPPED OVER HEAD FLASHING E2/AS1 COMPLIANT FLASHING 50 CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING 5mm MIN. GAP REQUIRED 5 MS SEALANT OR STO JOINT SEAL TAPE AS REQUIRED TO PLASTER/FLASHING SILL 15 SLOPE OVERHANG 30-50mm 40-75mm DRAINED CAVITY BRICK VENEER PLASTER BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS HORIZ.JUNCTION W'BD/ - OPT 1 SCALE 1:2 PB 803

71 BEVEL-BACK WEATHERBOARDS OVER 20mm DRAINED CAVITY FLASHING TAPE LAPPED OVER HEAD FLASHING CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING 50 MIN. 5mm GAP REQUIRED 5 1. IN HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm MIN.AND USE A RIGID UNDERLAY PACKER E2/AS1 COMPLIANT FLASHING MS SEALANT OR STO JOINT SEAL TAPE AS REQUIRED TO PLASTER/FLASHING BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS 40-75mm DRAINED CAVITY BRICK VENEER PLASTER SCALE 1:2 HORIZ.JUNCTION W'BD/ - OPT 2 PB 804

72 BRICK TIES SCREW FIX TO FRAMING PLASTER BRICK VENEER STO PRE MESHED CORNER ADHERE FC SHEET TO BRICK VENEER WITH FLEXIBLE GROUT 40-75mm DRAINED CAVITY END OF SLAB - LINE SHOWN DASHED. PROVIDE NIB TO SUPPORT END OF WALL WALL UNDERLAY CONTINUOUS AROUND CORNER NOMINAL 40x20mm H3.2 TIMBER CAVITY BATTENS STOARMAT PLASTER F C SHEET/STO BRICK VENEER - EXT.CNR SCALE 1:2 PB 820

73 40-75mm DRAINED CAVITY WALL UNDERLAY CONTINUOUS AROUND CORNER BRICK TIES SCREW FIX TO FRAMING MS SEALANT OVER STO JOINT SEAL TAPE OR PEF ROD STO 6mm PREMESHED FINISHING EDGE STOARMAT PLASTER ON 7.5/9.0mm FC SHEET OVER 20mm DRAINED CAVITY BRICK VENEER PLASTER F C SHEET/ - INT.CNR SCALE 1:2 PB 821

74 NOTCH IN SLAB REBATE TO ALLOW DRAINAGE FROM CAVITY BEHIND FC SHEET BRICK TIES SCREW FIX TO FRAMING 50mm MIN. 40x19mm H3.2 TIMBER CAVITY BATTENS WALL UNDERLAY 40-75mm DRAINED CAVITY BRICK VENEER PLASTER 30mm STOARMAT PLASTER ON FC SHEET OVER 20mm DRAINED CAVITY E2/AS1 COMPLIANT HEMED METAL FLASHING. MIN.30mm COVER TO BRICK VENEER MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROD 6mm MIN.GAP INSTALL FIBRE CEMENT SHEET AND SEAL BEFORE POREN BRICK VENEER PLASTER W'BOARD/ - VERTICAL JUNCTION SCALE 1:2 PB 822

75 STOARMAT PLASTER ON FC SHEET OVER 20mm DRAINED CAVITY 50mm MIN. 15mm DRIP EDGE 5mm FLASHING TAPE LAPPED OVER FLASHING CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING STO upvc CLIP ON TRAY 5mm MIN. GAP REQUIRED E2/AS1 COMPLIANT HEMED METAL FLASHING. MIN.30mm COVER TO BRICK VENEER 30mm MIN.COVER SILL 15 SLOPE OVERHANG 30-50mm 20mm MIN mm DRAINED CAVITY BRICK VENEER PLASTER BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS FC SHEET - HORIZONTAL JUNCTION - OPT 1 SCALE 1:2 PB 823

76 STOARMAT PLASTER ON FC SHEET OVER 20mm DRAINED CAVITY FLASHING TAPE LAPPED OVER FLASHING 50mm MIN. CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING STO upvc CLIP ON TRAY 5mm MIN. GAP REQUIRED 5 E2/AS1 COMPLIANT FLASHING IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm MIN.AND USE A RIGID UNDERLAY MS SEALANT OR STO JOINT SEAL TAPE AS REQUIRED TO PLASTER/FLASHING BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS 40-75mm DRAINED CAVITY BRICK VENEER PLASTER FC SHEET - HORIZONTAL JUNCTION - OPT 2 SCALE 1:2 PB 824

77 PURPOSE MADE FLASHING (SPECIFY COATING) PROFILED FOAM CLOSURE STRIP UNDER CLADDING FIXINGS IN ACCORDANCE WITH E2/AS1 HORIZONTAL METAL PROFILED WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROD 6mm MIN.GAP STO PREMESHED upvc ANGLE TO CORNERS END OF SLAB - LINE SHOWN DASHED. PROVIDE NIB TO SUPPORT END OF WALL WALL UNDERLAY CONTINUOUS AROUND CORNERS, POLYPROPYLENE FLASHING TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE BRICK TIES SCREW FIX TO FRAMING 40-75mm DRAINED CAVITY PLASTER BRICK VENEER REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZ.PROFILED METAL - EXT.CNR SCALE 1:2 PB 850

78 WALL UNDERLAY CONTINUOUS AROUND CORNER NOTCH IN SLAB REBATE TO ALLOW DRAINAGE FROM CAVITY BEHIND FC SHEET PACK AS REQUIRED ON DWANGS FOR FIXING FLASHING BRICK VENEER PLASTER STO 6mm PREMESHED FINISHING EDGE MS SEALANT OVER STO JOINT SEAL TAPE OR PEF ROD HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) PROFILED FOAM CLOSURE STRIP UNDER CLADDING FIXINGS IN ACCORDANCE WITH E2/AS x20mm H3.2 TIMBER CAVITY BATTENS E2/AS1 COMPLIANT BACK FLASHING. END RETURN TO SUIT BRICK VENEER DIMEMSIONS - KEEP FLASHING 3mm MIN.CLEAR OF BRICK VENEER NOTE: REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZ.PROFILED METAL - INT.CNR SCALE 1:2 PB 851

79 PROFILED FOAM CLOSURE STRIP UNDER CLADDING WALL UNDERLAY BRICK TIES SCREW FIX TO FRAMING 40-75mm DRAINED CAVITY HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) PURPOSE MADE FLASHING (SPECIFY COATING) - ALTERNATIVELY THIS CAN BE EXTENDED TO SUIT POREN BRICK VENEER - SHOWN DASHED 30mm MIN. 10 A 6 BRICK VENEER PLASTER MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROAD 6mm MIN.GAP NOTE: A = CHECK WITH SHEET METAL FOLDER A NARROW NECK MAY REQUIRE A WELDED JOINT. REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHING HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZ.PROFILED METAL - VERT.JUNCTION - OPT 1 SCALE 1:2 PB 852

80 40x19mm H3.2 TIMBER CAVITY BATTENS FIXINGS IN ACCORDANCE WITH E2/AS1 WALL UNDERLAY PROFILED FOAM CLOSURE STRIP UNDER CLADDING HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) PURPOSE MADE FLASHING (SPECIFY COATING) 30mm MIN.BACK COVER TO BRICK VENEER MS SEALANT ON STO JOINT SEAL TAPE STO PREMESHED CORNER 30 NOTE: HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZ.PROFILED METAL - VERT.JUNCTION - OPT 2 SCALE 1:2 PB 853

81 REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) FIXINGS IN ACCORDANCE WITH E2/AS1 CONTINUOUS CAVITY DRAINAGE CLOSURE STRIP FLASHING TAPE LAPPED OVER HEAD FLASHING CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING 5mm MIN. GAP REQUIRED E2/AS1 COMPLIANT FLASHING MS SEALANT OR STO JOINT SEAL TAPE AS REQUIRED TO PLASTER/FLASHING 20 SILL 15 SLOPE OVERHANG 30-50mm 40-75mm DRAINED CAVITY BRICK VENEER PLASTER BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS HORIZ.PROFILED METAL - HORIZ.JUNCTION - OPT 1 SCALE 1:2 ST 854

82 REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) FIXINGS IN ACCORDANCE WITH E2/AS1 CONTINUOUS CAVITY DRAINAGE CLOSURE STRIP FLASHING TAPE LAPPED OVER HEAD FLASHING CAVITY CLOSER POSITIONED TO GIVE 15mm MIN.DRIP EDGE TO CLADDING 5mm MIN. GAP REQUIRED IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mm MIN.AND USE A RIGID UNDERLAY 35mm COVER PACKER E2/AS1 COMPLIANT FLASHING MS SEALANT OR STO JOINT SEAL TAPE AS REQUIRED TO PLASTER/FLASHING BRICK TIES SCREW FIXED TO FRAMING MORTAR FLUSH POINT JOINTS 40-75mm DRAINED CAVITY BRICK VENEER PLASTER HORIZ.PROFILED METAL - HORIZ.JUNCTION - OPT 2 SCALE 1:2 PB 855

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING AND 9mm MIN.H3 PLY - PACKED TO A FALL 5 PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL Z Z REFER TABLE 7 - E2/AS1 CARRY MESH/RENDER UP TO TOP

More information

STOPOREN FACADE SYSTEM APRON FLASHING

STOPOREN FACADE SYSTEM APRON FLASHING 10 REFER E2/AS1 TABLE 7 STOPEND TO PROJECT 10mm MIN. PAST FINISHED CLADDING STO VENTED ADJUSTABLE FOOT TRAY PRE FINISHED METAL APRON FLASHING PREFINISHED METAL ROOFING OVER UNDERLAY ROOF STRUCTURE 5mm

More information

STOTHERM MASONRY INSULATION SYSTEM DRAWING REGISTER

STOTHERM MASONRY INSULATION SYSTEM DRAWING REGISTER Drawing Description STO DRAWING REGISTER Drawing No. Drawing Register STM 001-002 Introduction Series 000 StoTherm Masonry Insulation System - Introduction STM 003 Block Layout Series 100 StoTherm Masonry

More information

STOTHERM INSULATED FACADE SYSTEM DRAWING REGISTER

STOTHERM INSULATED FACADE SYSTEM DRAWING REGISTER Drawing Description STO DRAWING REGISTER Drawing No. Drawing Register ST 001-005 Introduction Series 000 StoTherm Insulated Facade System Introduction ST 006 StoTherm Insulated Facade System Reinforcing

More information

STOTHERM INSULATED FACADE SYSTEM FOUNDATION SLAB-ON-GROUND

STOTHERM INSULATED FACADE SYSTEM FOUNDATION SLAB-ON-GROUND INTERIOR LINING TIMBER FRAMING TO NZS 3604 20mm VH CAVITY BATTENS RENDER CAVITY SPACERS TO SUIT S INSULATION AS PER NZBC H1/AS1 DPM clad. CONCRETE SLAB/REINFORCING AS PER NZS 3604 OR ENGINEER SPECIFIC

More information

STOPOREN FACADE SYSTEM FOUNDATION SLAB-ON-GROUND

STOPOREN FACADE SYSTEM FOUNDATION SLAB-ON-GROUND INTERIOR LINING TIMBER FRAMING TO NZS 3604 STO 20mm VH CAVITY BATTENS RENDER SYSTEM PANEL CAVITY SPACERS TO SUIT FIXINGS INSULATION AS PER NZBC H1/AS1 DPM clad. CONCRETE SLAB/REINFORCING AS PER NZS 3604

More information

SS505 StoPoren Brick Veneer Construction 1

SS505 StoPoren Brick Veneer Construction 1 SS505 StoPoren Brick Veneer Construction 1 STOPOREN BRICK VENEER CONSTRUCTION STOPOREN PLASTER ON POREN BRICK VENEER SPECIFICATION BRANZ Appraisal No 739 (2011) - ACAD Details www.sto.co.nz building with

More information

SS506 StoArmat Poren Brick Veneer System 1

SS506 StoArmat Poren Brick Veneer System 1 SS506 StoArmat Poren Brick Veneer System 1 Stoanz Ltd Authorized partner of Sto STOARMAT POREN BRICK CONSTRUCTION STOARMAT PLASTER SYSTEM ON POREN BRICK VENEER SPECIFICATION BRANZ Appraisal No 739 (2011)

More information

A Sto QA Form is required to be filled out by the various parties involved for the Sto Warranty.

A Sto QA Form is required to be filled out by the various parties involved for the Sto Warranty. SS508 StoMiral Plaster System 1 Stoanz Ltd Authorized partner of Sto STO MIRAL PLASTER OVER BRICK SPECIFICATION STO MULTISCREED PLASTER OVER NEW OR OLD BRICK CONSTRUCTION Based on BRANZ Appraisal No 515

More information

Technical & Installation Manual

Technical & Installation Manual Technical & Installation Manual Product Description and Construction Details March 2016 V2.1 Office: 0800 484 552 or 03-313 3672 E-Mail: info@villagestone.co.nz Web Site: www.villagestonechristchurch.co.nz

More information

STOTHERM INSULATED FACADE SYSTEM

STOTHERM INSULATED FACADE SYSTEM RENDER PANEL PANEL FIXING 20mm VH CAVITY BATTEN STO upvc END CAP/MS SEALANT 50mm STO upvc 6mm FINISHING EDGE E2/AS1 COMPLIANT METAL FLASHING 10mm 100mm PROFILED FOAM CLOSURE STRIP UNDER CLADDING HORIZONTAL

More information

SS806 StoStucco Roughcast System 1

SS806 StoStucco Roughcast System 1 SS806 StoStucco Roughcast System 1 Stoanz Ltd Authorized partner of Sto AG STOSTUCCO PEBBLE DASH ON STO S/S LATH SPECIFICATION STOSTUCCO ROUGHCAST ON STO STAINLESS LATH CONSTRUCTION BRANZ Appraisal No

More information

EXT.CORNER - MANUF.STONE/FC SHEET

EXT.CORNER - MANUF.STONE/FC SHEET STOARMAT RENDER SYSTEM 7.5/9.0mm REBATED FC SHEET TIMBER FRAMING WALL UNDERLAY CONTINUOUS AROUND CORNERS, POLYPROPYLENE FLASHING TAPE APPLIED TO PROTECT WALL UNDERLAY 75mm MIN.WIDE STO upvc CLIP ON FLASHING

More information

SS202 Sto Concrete Block Plaster System 1

SS202 Sto Concrete Block Plaster System 1 SS202 Sto Concrete Block Plaster System 1 Stoanz Ltd Authorized partner of Sto STOARMAT MIRAL PLASTER SYSTEM SPECIFICATION STOARMAT MIRAL PLASTER OVER REINFORCED BLOCK CONSTRUCTION BRANZ Appraisal No 515

More information

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity) September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening

More information

CELCRETE PANEL VENEER SYSTEM TECHNICAL MANUAL. Product Description and Building System Details SEPTEMBER 2012

CELCRETE PANEL VENEER SYSTEM TECHNICAL MANUAL. Product Description and Building System Details SEPTEMBER 2012 CELCRETE PANEL VENEER SYSTEM TECHNICAL MANUAL Product Description and Building System Details SEPTEMBER 2012 Head Office: Celcrete International Limited 81 Maleme Street, P.O. Box 2382 TAURANGA Ph: 07

More information

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01.

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01. BRICKVENEERS Specifications Bowers Brick Veneer meets the requirements of AS/NZS 4455 as a masonry brick veneer and complies with and exceeds the 15 year durability requirements as stated in the New Zealand

More information

PANEL SYSTEMS TECHNICAL MANUAL PRODUCT DESCRIPTION AND BUILDING SYSTEM DETAILS

PANEL SYSTEMS TECHNICAL MANUAL PRODUCT DESCRIPTION AND BUILDING SYSTEM DETAILS PANEL S TECHNICAL MANUAL PRODUCT DESCRIPTION AND BUILDING DETAILS Edition May 2018 (always refer to the latest manual as set out on www.loxocladding.co.nz) Head Office: Loxo Cladding NZ Limited PO Box

More information

STOPOREN BLOCK VENEER CLADDING SYSTEM. Product. Scope. Appraisal No. 739 [2012] Appraisal No. 739 (2012) Amended 11 November 2015.

STOPOREN BLOCK VENEER CLADDING SYSTEM. Product. Scope. Appraisal No. 739 [2012] Appraisal No. 739 (2012) Amended 11 November 2015. STOPOREN BLOCK VENEER CLADDING SYSTEM Amended 11 November 2015 BRANZ Appraisals Technical Assessments of products for building and construction. Stoanz Limited 72 Abel Smith Street Wellington Tel: 04 801

More information

STOLITE STUCCO CLADDING SYSTEM. Product. Scope. Appraisal No. 468 [2018]

STOLITE STUCCO CLADDING SYSTEM. Product. Scope. Appraisal No. 468 [2018] STOLITE STUCCO CLADDING This Appraisal replaces BRANZ Appraisal No. 468 (2005). s Technical Assessments of products for building and construction. Stoanz Limited 72 Abel Smith Street Wellington Tel: 04

More information

Dear Customer. Section Old E2 December 2011 Errata to E2

Dear Customer. Section Old E2 December 2011 Errata to E2 Dear Customer Please find enclosed, effective 24 December 2011, to the Compliance Document for Clause E2 External Moisture of the New Zealand Building Code. Section Old E2 December 2011 Errata to E2 Title

More information

nu-wall aluminium vertical cladding system

nu-wall aluminium vertical cladding system Product Appraisal No.556 [2007] BRANZ Appraisals 1.1 The Nu-Wall Aluminium Vertical Cladding System is a direct fixed, inter-locking powder coated aluminium weatherboard system. It is designed to be used

More information

PARKSIDE QUARRIES Ltd

PARKSIDE QUARRIES Ltd 5mm min. vent space soffit lining optional 20x20 bead optional cavity vents formed to top course of veneer 2 5 Wall ties screw fixed over underlay to structural frame and positioned within 300mm or two

More information

PUTZ TECHNIK SYSTEM 300

PUTZ TECHNIK SYSTEM 300 PUTZ TECHNIK MINERAL PLASTER TECHNOLOGY SYSTEM 300 TECHNICAL MANUAL Product Description and Installation Details Version 1 January 2007 Putz-Technik 27A Neilpark Drive East Tamaki Auckland SYSTEM 300 System

More information

NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM. Product. Scope. Appraisal No. 556 [2007] Appraisal No. 556 (2007) Amended 20 November 2015.

NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM. Product. Scope. Appraisal No. 556 [2007] Appraisal No. 556 (2007) Amended 20 November 2015. NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM Amended 20 November 2015. BRANZ Appraisals Technical Assessments of products for building and construction. Aluminium Product Brands NZ Limited 750B Great South

More information

weathertex sheet Product BRANZ APPRAISAL No. 514 (2006) Scope Weathertex Pty Ltd P O Box 21 Raymond Terrace NSW 2324 Australia

weathertex sheet Product BRANZ APPRAISAL No. 514 (2006) Scope Weathertex Pty Ltd P O Box 21 Raymond Terrace NSW 2324 Australia Product Appraisal No.514 [2006] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Weathertex Sheet and Architectural Panel Cavity System is a cavity-based external

More information

Product. BRANZ APPRAISAL No. 468 (2005) Scope. Stoanz Ltd 72 Abel Smith Street Wellington Tel: Fax: Internet:

Product. BRANZ APPRAISAL No. 468 (2005) Scope. Stoanz Ltd 72 Abel Smith Street Wellington Tel: Fax: Internet: Product Appraisal No.468 [2005] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 Sto Lite is a cavity-based monolithic plaster wall cladding. It is designed to be used

More information

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options *lum ngle 50x50x1.6mm min. with 20mm lum fixing bar to mechanically secure membrane Enviroclad Waterproofing Membrane Substrate to comply with current Roofspec Masterspec specification Substrate Checksheet

More information

Product. BRANZ APPRAISAL No. 769 (2012) Scope. Celcrete International Ltd PO Box 2382 Tauranga

Product. BRANZ APPRAISAL No. 769 (2012) Scope. Celcrete International Ltd PO Box 2382 Tauranga Product Appraisal No.769 [2012] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Celcrete 50 mm Panel Veneer Cavity Cladding System is a cavity-based external wall

More information

INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL

INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL Foamex Polystyrene Pty Ltd 31 Mavis Street Revesby NSW 2212 AUSTRALIA Tel: +61 2 9773 1655 Fax: +61 2 9773 1907 Email: nswsales@foamex.com.au

More information

nu-age nu-lite Product BRANZ APPRAISAL No. 459 (2004) Scope Nu-Age Plaster Limited PO Box 195 Matamata

nu-age nu-lite Product BRANZ APPRAISAL No. 459 (2004) Scope Nu-Age Plaster Limited PO Box 195 Matamata Product Appraisal No.459 [2004] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 Nu-Age NU-LITE is a cavity-based monolithic plaster wall cladding. It is designed to

More information

STOTHERM MASONRY INSULATION SYSTEM. Product. Scope. Appraisal No. 604 [2008] Appraisal No. 604 (2008) Amended 11 November 2015.

STOTHERM MASONRY INSULATION SYSTEM. Product. Scope. Appraisal No. 604 [2008] Appraisal No. 604 (2008) Amended 11 November 2015. Amended 11 November 2015. s Technical Assessments of products for building and construction. Stoanz Limited 72 Abel Smith Street Wellington Tel: 04 801 7794 Fax: 04 384 9828 Email: info@sto.co.nz Web:

More information

Product. BRANZ APPRAISAL No. 553 (2007) Scope. Nuplex Industries Ltd C/- Nuplex Construction Products PO Box Glenfield Auckland

Product. BRANZ APPRAISAL No. 553 (2007) Scope. Nuplex Industries Ltd C/- Nuplex Construction Products PO Box Glenfield Auckland Product Appraisal No.553 [2007] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Graphex Cavity Based Solid Plaster System is a cavity-based Exterior Insulation

More information

Stutex Stone Veneer Cladding System

Stutex Stone Veneer Cladding System Stutex Stone Veneer Cladding System TECHNICAL & INSTALLATION MANUAL January 2018 The stone product is manufactured by Cerastone Co Ltd, Korea, and distributed by Stutex Stone NZ Ltd This manual is to be

More information

nu-therm system Product BRANZ APPRAISAL No. 456 (2005) Scope Nu-Age Plaster Limited P O Box 195 Matamata

nu-therm system Product BRANZ APPRAISAL No. 456 (2005) Scope Nu-Age Plaster Limited P O Box 195 Matamata Product Appraisal No.456 [2005] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 NU-THERM is a cavity-based Exterior Insulation and Finishing System (EIFS) wall cladding.

More information

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM. Product. Scope. Appraisal No. 501 [2017]

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM. Product. Scope. Appraisal No. 501 [2017] PUTZ TECHNIK SYSTEM 300 This Appraisal replaces BRANZ Appraisal No. 501 (2006) BRANZ Appraisals Technical Assessments of products for building and construction. RHS (NZ) Ltd, Trading as Putz Technik P

More information

ROCKCOTE RESENE MONOTEK SYSTEMS

ROCKCOTE RESENE MONOTEK SYSTEMS Product Appraisal No.500 [2007] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Rockcote Resene Monotek Systems consists of the Rockcote Resene Monotek Texture

More information

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM

PUTZ TECHNIK SYSTEM 300 CAVITY SYSTEM Product BRANZ Appraisals Technical Assessments of products for building and construction 1.1 Putz Technik System 300 is a cavity-based Exterior Insulation and Finishing System (EIFS) wall cladding. It

More information

NZ Brick Distributors Canterbury Clay Bricks Clay Bricks Ltd Brick and Stone Imports T/A Midland Brick NZ Full contact details are given on page 9.

NZ Brick Distributors Canterbury Clay Bricks Clay Bricks Ltd Brick and Stone Imports T/A Midland Brick NZ Full contact details are given on page 9. TWO STOREY BRICK VENEER This Appraisal replaces BRANZ Appraisal No. 690 (2010) BRANZ Appraisals Technical Assessments of products for building and construction. Clay Brick & Paver Manufacturers Association

More information

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland Product Appraisal No.557 [2007] BRANZ Appraisals 1.1 The Nu-Wall Aluminium Direct Fixed Cladding System is a direct fixed, interlocking powder coated aluminium weatherboard system. It is designed to be

More information

MONOTEK SHEET - CAVITY CONSTRUCTION

MONOTEK SHEET - CAVITY CONSTRUCTION Product BRANZ Appraisals Technical Assessments of products for building and construction 1.1 Monotek Sheet _ Cavity Construction is a cavity-based, flush-finished, monolithic plaster wall cladding. It

More information

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3 TECHNICAL MANUAL Wall System Descriptions and Building Details May 13, 2013 V1.3 Head Office: 03-310 7981 E-Mail: mark@cladx.co.nz Web Site: www.cladx.co.nz Contact: 027 600 1234 TABLE OF CONTENTS 2 1

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Product. BRANZ APPRAISAL No. 633 (2009) Scope. Rockcote Resene Limited PO Box Harewood Christchurch 8545

Product. BRANZ APPRAISAL No. 633 (2009) Scope. Rockcote Resene Limited PO Box Harewood Christchurch 8545 Product Appraisal No.633 [2009] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Graphex Insulated Façade System is a cavity-based Exterior Insulation and Finishing

More information

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016 WEATHERBOARD CAVITY SYSTEM Amended 05 February 2016 BRANZ Appraisals Technical Assessments of products for building and construction. Flashclad Limited PO Box 346 Kaiapoi 7633 North Canterbury Tel: 0800

More information

INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL

INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL INSULCLAD EXTERIOR CLADDING SYSTEMS DESIGN AND INSTALLATION MANUAL Foamex Polystyrene Pty Ltd 31 Mavis Street Revesby NSW 2212 AUSTRALIA Tel: +61 2 9773 1655 Fax: +61 2 9773 1907 Email: nswsales@foamex.com.au

More information

Product. BRANZ APPRAISAL No. 789 (2012) Scope. Hard as Rocks Ltd PO Box 1703 Taupo 1351

Product. BRANZ APPRAISAL No. 789 (2012) Scope. Hard as Rocks Ltd PO Box 1703 Taupo 1351 Product Appraisal No.789 [2012] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Eldorado Stone Veneer and Hard as Rocks Application System is a cavitybased external

More information

JENKIN A-LIGN BEVELBACK WEATHERBOARD DIRECT FIXED CLADDING SOLUTION

JENKIN A-LIGN BEVELBACK WEATHERBOARD DIRECT FIXED CLADDING SOLUTION Product Appraisal No.536 [2007] 1.1 The Solution is an external wall cladding system for residential and light commercial type buildings where domestic construction techniques are used. 1.2 The system

More information

SMARTCLAD BEVELBACK WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 684 [2017]

SMARTCLAD BEVELBACK WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 684 [2017] SMARTCLAD BEVELBACK WEATHERBOARD CAVITY CLADDING SYSTEM This Appraisal replaces BRANZ Appraisal No. 684 (2010) BRANZ Appraisals Technical Assessments of products for building and construction. PurePine

More information

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz.

Plastercrete. Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED. plastercrete.co.nz. Plastercrete aac facade system Drained & Ventilated AAC Facade System Design and Installation Guide 100% NZ OWNED plastercrete.co.nz Contents TABLE OF CONTENTS 1 1 GENERAL DESCRIPTION 4 2 COMLIANCE WITH

More information

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals ECOPLY BARRIER FOR STEEL s Technical Assessments of products for building and construction. Carter Holt Harvey Plywood Limited Private Bag 92-106 Auckland Tel: 0800 326 759 Fax: 09 633 1582 Web: www.chhwoodproducts.co.nz

More information

SS909 StoProtect - Architectural Blocks 1

SS909 StoProtect - Architectural Blocks 1 SS909 StoProtect - Architectural Blocks 1 Stoanz Ltd Authorized partner of Sto AG STOPROTECT CLEAR COATING SPECIFICATION OVER EXTERIOR ARCHITECTUAL CONCRETE BLOCK CONSTRUCTION Complies with CCANZ CP 01:

More information

Bituminous Roofing Underlay & Valley Guard

Bituminous Roofing Underlay & Valley Guard CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation Information...

More information

Bituminous Building Paper

Bituminous Building Paper CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation... 5 Size Range

More information

JENKIN A-LIGN BEVELBACK WEATHERBOARD CONCEALED FIX CAVITY SOLUTION. Product. Scope. Appraisal No. 751 [2011]

JENKIN A-LIGN BEVELBACK WEATHERBOARD CONCEALED FIX CAVITY SOLUTION. Product. Scope. Appraisal No. 751 [2011] JENKIN A-LIGN BEVELBACK WEATHERBOARD CONCEALED FIX CAVITY SOLUTION Amended 03 September 2013. s Technical Assessments of products for building and construction. Jenkin Timber Limited PO Box 21702 Henderson

More information

weathertex weatherboard direct fixed

weathertex weatherboard direct fixed Product Appraisal No.511 [6] 1.1 The Weathertex Weatherboard Direct Fixed Cladding System is an external wall cladding system for residential and light commercial type buildings where domestic construction

More information

enduron LWC Product BRANZ APPRAISAL No. 720 (2012) Scope Rockcote Resene Limited PO Box Harewood Christchurch 8545

enduron LWC Product BRANZ APPRAISAL No. 720 (2012) Scope Rockcote Resene Limited PO Box Harewood Christchurch 8545 Product Appraisal No.720 [2012] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Enduron LWC Façade System is a cavity-based external wall cladding system for residential

More information

FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 800 [2013] Appraisal No. 800 (2013) Amended 05 February 2016.

FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM. Product. Scope. Appraisal No. 800 [2013] Appraisal No. 800 (2013) Amended 05 February 2016. FLASHCLAD HORIZONTAL WEATHERBOARD CAVITY CLADDING SYSTEM Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction. Flashclad Limited PO Box 346 Kaiapoi

More information

Jenkin a-lign. Product. BRANZ APPRAISAL No. 751 (2011) Scope. Jenkin Timber Limited PO Box Henderson Auckland. Tel: Fax:

Jenkin a-lign. Product. BRANZ APPRAISAL No. 751 (2011) Scope. Jenkin Timber Limited PO Box Henderson Auckland. Tel: Fax: Product Appraisal No.751 [2011] BRANZ Appraisals Technical Assessments of products for building and construction 1.1 The Solution is a cavity-based external wall cladding solution for residential and light

More information

INTEGRA LIGHT WEIGHT CONCRETE FACADE SYSTEM. Product. Scope. Appraisal No. 681 [2010] Appraisal No. 681 (2010) Amended 06 March 2018.

INTEGRA LIGHT WEIGHT CONCRETE FACADE SYSTEM. Product. Scope. Appraisal No. 681 [2010] Appraisal No. 681 (2010) Amended 06 March 2018. INTEGRA LIGHT WEIGHT CONCRETE FACADE SYSTEM Amended 06 March 2018 BRANZ Appraisals Technical Assessments of products for building and construction. Rockcote Resene Limited PO Box 39108 Harewood Christchurch

More information

BGC DURAGROOVE AND DURASCAPE FACADE SYSTEMS (CAVITY) Product. Scope. Appraisal No. 799 [2013] Appraisal No. 799 (2013) Amended 14 October 2015

BGC DURAGROOVE AND DURASCAPE FACADE SYSTEMS (CAVITY) Product. Scope. Appraisal No. 799 [2013] Appraisal No. 799 (2013) Amended 14 October 2015 BGC DURAGROOVE AND DURASCAPE FACADE SYSTEMS Amended 14 October 2015 BRANZ Appraisals Technical Assessments of products for building and construction. Appraisal Holder: BGC Fibre Cement Australia Pty Ltd

More information

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017 ECOPLY RIGID AIR Amended 21 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Carter Holt Harvey Plywood Ltd Private Bag 92-106 Auckland Tel: 0800 326 759 Fax:

More information

UNITEX BASE BOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 758 [2011] Appraisal No. 758 (2011) BRANZ Appraisals

UNITEX BASE BOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 758 [2011] Appraisal No. 758 (2011) BRANZ Appraisals UNITEX BASE BOARD CAVITY BRANZ Appraisals Technical Assessments of products for building and construction. Unitex Granular Marble Pty Ltd 22 Park Drive Dandenong Victoria 3175 AUSTRALIA Tel: +61 3 9768

More information

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE BRANZ Appraised Appraisal No. 547 [2007] NURALITE Nuralite Waterproofing Ltd. 53A Victoria Street, Onehunga, Auckland 1061, Zealand TEL: (64) (9) 579-2046 FAX: (64) (9) 579-5136 email: info@nuralite.co.nz

More information

BGC STRATUM AND STRATUM DUO CAVITY CLADDING SYSTEMS. Product. Scope. Appraisal No. 847 [2013] Appraisal No. 847 (2013) Amended 14 October 2015

BGC STRATUM AND STRATUM DUO CAVITY CLADDING SYSTEMS. Product. Scope. Appraisal No. 847 [2013] Appraisal No. 847 (2013) Amended 14 October 2015 STRATUM DUO CAVITY CLADDING SYSTEMS Amended 14 October 2015 BRANZ Appraisals Technical Assessments of products for building and construction. Appraisal Holder: BGC Fibre Cement Australia Pty Ltd Marketed

More information

CONSTRUCTION GUIDE. ELDORADO STONE VENEER AND HARD AS ROCKS APPLICATION SYSTEM VERSION 1.1 February 2016

CONSTRUCTION GUIDE. ELDORADO STONE VENEER AND HARD AS ROCKS APPLICATION SYSTEM VERSION 1.1 February 2016 CONSTRUCTION GUIDE ELDORADO STONE VENEER AND HARD AS ROCKS APPLICATION SYSTEM VERSION 1.1 February 2016 FOR YOUR LOCAL LICENSED APPLICATOR AND HARD AS ROCKS DISTRIBUTOR PLEASE PHONE 0800 353 672 PRODUCT

More information

All work in this section shall be the responsibility of the Main Contractor, unless otherwise expressly agreed.

All work in this section shall be the responsibility of the Main Contractor, unless otherwise expressly agreed. Standard specification for THERMEXX Plaster System incorporating Keim Silikatputz finishing plaster and Keim Soldalit Sol-Silicate paint to EIFS cavity construction onto light timber frame. Pages 1 of

More information

Limitations and Conditions

Limitations and Conditions RESENE CONSTRUCTION S MASONRY RENDER s Technical Assessments of products for building and construction. Rockcote Resene Ltd T/A Resene Construction Systems PO Box 39108 Harewood Christchurch Tel: 03 338

More information

Finish coat painted with a 100% acrylic. Multi purpose scratch coat

Finish coat painted with a 100% acrylic. Multi purpose scratch coat Finish coat painted with a 100% acrylic Multi purpose scratch coat 200mm self-adhesi ve mesh coated with insulclad base 40mm P VC washers and class 3 screws spaced at 300mm INSULCLAD CAVITY SYSTEM Amended

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION 1 GENERAL 1.1 STANDARDS Materials and construction: To AS 4773.1 and AS 4773.2. 2 PRODUCTS 2.1 DURABILITY Exposure environment: [complete/delete] Exposure locations: To

More information

Finish coat painted with a 100% acrylic. Multi purpose scratch coat

Finish coat painted with a 100% acrylic. Multi purpose scratch coat Product Appraisal No.696 [2010] BRANZ Appraisals 1.1 The Insulclad Direct Fixed Cladding System is an Exterior Insulation and Finishing System (EIFS) wall cladding. It is an external wall cladding system

More information

MLC MASONRY AND BRICK PLASTER SYSTEM. Product. Scope. Appraisal No. 839 [2013] Appraisal No. 839 (2013) BRANZ Appraisals

MLC MASONRY AND BRICK PLASTER SYSTEM. Product. Scope. Appraisal No. 839 [2013] Appraisal No. 839 (2013) BRANZ Appraisals MLC MASONRY AND BRICK PLASTER SYSTEM BRANZ Appraisals Technical Assessments of products for building and construction. Specialized Construction Products Ltd PO Box 101 127 North Shore Mail Centre Auckland

More information

Refusal to issue a building consent for a house with insulated concrete walls at 11 York Road, Riversdale, Southland

Refusal to issue a building consent for a house with insulated concrete walls at 11 York Road, Riversdale, Southland Determination 2009/104 Refusal to issue a building consent for a house with insulated concrete walls at 11 York Road, Riversdale, Southland 1. The matters to be determined 1.1 This is a determination under

More information

BENCHMARK Evolution Axis

BENCHMARK Evolution Axis Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL

More information

Determination 2007/10

Determination 2007/10 Determination 2007/10 Refusal of a code compliance certificate for additions to a building with timber weatherboards, profiled metal and monolithic cladding systems at 283 Maitai Valley Road, Nelson 1.

More information

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System EXPIRES MAR 2018 BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System Product 1.1 The PLASTERCRETE NZ AAC Wall Panel System (PAWPS) is a drained and ventilated masonry veneer wall cladding

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

MITTEN CAMBRIDGE AND CEDARLINE VINYL CLADDINGS. Product. Scope. Appraisal No. 814 [2013] Appraisal No. 814 (2013) Amended 22 December 2014

MITTEN CAMBRIDGE AND CEDARLINE VINYL CLADDINGS. Product. Scope. Appraisal No. 814 [2013] Appraisal No. 814 (2013) Amended 22 December 2014 MITTEN CAMBRIDGE AND CEDARLINE VINYL CLADDINGS Amended 22 December 2014 BRANZ Appraisals Technical Assessments of products for building and construction. Mitten Inc. 5A, 225 Henry Street Brantford, Ontario

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/ General conditions. TYPES OF COVERING 115A SINGLE LAYER REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING warm roofing system

More information

A-lign Technical Manual

A-lign Technical Manual A-lign Technical Manual Rusticated Weatherboard Nail-free Boardface High Moisture Protection Fast Install & Less Waste Primed & Undercoated Superior Face Finish System Solution From Renewable Wood NZBC

More information

11/09/2018 LBP licence classes

11/09/2018 LBP licence classes LBP licence classes Occupational Licensing aims to ensure that people in the building industry are competent and accountable so that homes and buildings are designed and built right first time. Summary

More information

Residential Wall Panel Installation

Residential Wall Panel Installation Residential Wall Panel Installation Planning & System Parameters 1. Health & Safety Act 1992 The principle objects of the Health & Safety Employment Act 1992 (HSE Act) are to prevent harm to employees

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

Enviro. AAC Wall Panel TECHNICAL MANUAL. CMA-CM40041

Enviro. AAC Wall Panel TECHNICAL MANUAL.   CMA-CM40041 Enviro AAC Wall Panel CMA-CM40041 www.masons.nz INSULATED BY AERATED CONCRETE Aluminium paintable weep-hole vent CODE: VENT Enviro AAC Wall Panel Full Flashing system compliant to E2/VM1 Weathertight Testing

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces. BRANZ Appraised No. 678 Ref: P3200 Rev 1 February 2016 Page 1 of 5 1.0 PREAMBLE:

More information

Regarding the refusal to issue a code compliance certificate for a 13-year-old house at 14 Patsy O Hara Place, Swanson, Auckland

Regarding the refusal to issue a code compliance certificate for a 13-year-old house at 14 Patsy O Hara Place, Swanson, Auckland Determination 2011/077 Regarding the refusal to issue a code compliance certificate for a 13-year-old house at 14 Patsy O Hara Place, Swanson, Auckland 1. The matter to be determined 1.1 This is a determination

More information

TYPICAL ROOF CONDITION LAYOUT

TYPICAL ROOF CONDITION LAYOUT FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

PALLISIDE CELLULAR upvc WEATHERBOARD DIRECT FIXED CLADDING SYSTEM. Product. Scope. Appraisal No. 490 [2015]

PALLISIDE CELLULAR upvc WEATHERBOARD DIRECT FIXED CLADDING SYSTEM. Product. Scope. Appraisal No. 490 [2015] PALLISIDE CELLULAR upvc WEATHERBOARD DIRECT FIXED The Appraisal replaces BRANZ Appraisal No. 490 (2005). Amended 30 October 2017 BRANZ Appraisals Technical Assessments of products for building and construction.

More information

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C Stratum Guard I and II System Installation Details Stratum Guard I and II DETAIL Table of Contents NOTE SG.0.0.01 SG.0.0.02

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

ThermalCrete. AAC Wall Panel LIGHTWEIGHT PANEL SYSTEM. CMA-CM40073

ThermalCrete. AAC Wall Panel LIGHTWEIGHT PANEL SYSTEM.   CMA-CM40073 ThermalCrete AAC Wall Panel CMA-CM40073 LIGHTWEIGHT PANEL SYSTEM www.masons.nz INSULATED BY AERATED CONCRETE...AND 3-5mm EPS BEADS The full system of ThermalCrete plastered with blue FLX Acrylic plaster

More information

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland Product 1.1 Watergate-Plus is a fire retardant, flexible synthetic wall underlay for use under direct fixed and non-direct fixed wall cladding on timber and steel framed buildings. The product is manufactured

More information

Light-Metal Roof Edge, Raised

Light-Metal Roof Edge, Raised NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED

More information

Triclad Board (and Batten) June 2013

Triclad Board (and Batten) June 2013 Triclad Board (and Batten) June 2013 www.triclad.co.nz Ph. 0800 TRICLAD 1 Please note it is the responsibility of the Specifier and the party responsible for the project, to make sure they have the latest

More information

Triclad Lapped Weatherboard June 2013

Triclad Lapped Weatherboard June 2013 Triclad Lapped Weatherboard June 2013 www.triclad.co.nz Ph. 0800 TRICLAD 1 Please note it is the responsibility of the Specifier and the party responsible for the project, to make sure they have the latest

More information

Compliance Document for New Zealand Building Code Clause E2 External Moisture

Compliance Document for New Zealand Building Code Clause E2 External Moisture Compliance Document for New Zealand Building Code Clause E2 External Moisture Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building and Housing.

More information

Acceptable Solutions and Verification Methods For New Zealand Building Code Clause E2 External Moisture

Acceptable Solutions and Verification Methods For New Zealand Building Code Clause E2 External Moisture Acceptable Solutions and Verification Methods For New Zealand Building Code Clause E2 External Moisture E2 Status of Verification Methods and Acceptable Solutions Verification Methods and Acceptable Solutions

More information